Model:
PLFY-P12NLMU-E
Job Name:
Location:
Drawing Reference:
Schedule No.
System No.:
Date:
Net Weight
Unit………………..…...……………................ 53 lbs. / 24 kg
Grille……
…………..…...…………….............. 15 lbs. / 6.5 kg
Coil Type………………...........................................….Cross Fin
(Aluminum Plate Fin and Copper Tube)
Fan
Type x Quantity………………..………….........…
....... Turbo fan x1
Airflow Rate (Low-Mid-High) ..................... 230 - 282 - 335 CFM
GENERAL FEATURES
•
•
•
•
•
•
•
R410A refrigerant
Lightweight and compact desgin
Five sizes from 6,000 to 18,000 Btu/h
Three fan speed settngs
Built-in condensate lift mechanism; lifts to 11-1/32 in.
Quiet operation from 27 to 38 dB(A)
Outside air capability
SPECIFICATIONS
Capacity*
Cooling…………………………………………….… 12,000 Btu/h
Heating…………………………………………….… 13,500 Btu/h
Power
Power Source………………..........208 / 230V, 1-phase, 60Hz
Power Consumption
Cooling………………………………………... 0.068 / 0.075 kW
Heating………………………………………... 0.068 / 0.075 kW
Current
Cooling……...................................................…... 0.34 / 0.37 A
Heating……...................................................…... 0.34 / 0.37 A
Minimum Circuit Ampacity (MCA)……………….….. 0.43 / 0.47 A
Maximum Overcurrent Protection (MOCP) Fuse..….......…..15 A
External Finish……..... Grille (No. 0.7Y 8.59 / 0.97)
Unit Dimensions
Inches…………………….. 11-7/16 H x 30-9/16 W x 24-31/32 D
mm……………………………………... 290 H x 776 W x 634 D
Grille Dimensions
Inches……........................ 13/16 H x 42-17/32 W x 27-31/32 D
mm………………………………...…... 20 H x 1080 W x 710 D
Notes:
Motor
Type………..………..……….......... 1-phase induction motor
Output………..………..………..………..………..….0.015 kW
Air Filter..……………………………................... Standard Filter
Refrigerant Piping Dimensions
Liquid (High Pressure)……............1/4" / 6.35 mm (Flared)
Gas (Low Pressure)………………..1/2" / 12.7 mm (Flared)
Drainpipe Dimension……............……...... O.D. 1-1/4" / 32 mm
Sound Pressure Levels
Low-Mid-High........(208V)....................... 27 - 30 - 33 dB(A)
Low-Mid-High........(230V)....................... 28 - 31 - 34 dB(A)
OPTIONS
□ External Heat Adaptor................................... PAC-YU25HT
□ OA Duct Flange............................................. PAC-KH11OF
* Cooling / Heating capacity indicated at the maximum value at
operation under the following conditions:
Cooling: Indoor 80°F (27°C) DB / 67°F (19°C) WB, Outdoor 95°F
(35°C) DB
Heating: Indoor 70°F (21°C) DB, Outdoor 47°F (8°C) DB / 43°F (6°C)
WB
Note: Ventilation air: Providing suf ficient ventilation air is an important part of every building design. ASHRAE Standard 62 provides
the minimum ventilation air requirement. Also, check local codes.
222(8-3/4)
190(7-1/2)
20(13/16)
PLFY-P18NLMU-E
CMP-63VLW-B
Model
PLFY-P06NLMU-E
PLFY-P08NLMU-E
CMP-40VLW-B
PLFY-P12NLMU-E
PLFY-P15NLMU-E
B
C
D
A
B
E
217.5X2=435(8-19/32X2=17-5/32)
D(Suspension bolt pitch)
C
B(Opening dimension)
1250
1210
946
473
994
(49-7/32) (47-21/32) (37-1/4) (39-5/32) (18-5/8)
1080
1040
388
776
824
(42-17/32) (40-31/32) (30-9/16) (32-15/32) (15-9/32)
A
Standard center panel
Fresh air intake 240X45(9-15/32X1-25/32) knock out hole
197(7-25/32)
240(9-15/32)
Branch duct FX110(4-11/32) knock out hole (both side)(Note:2)
45 216(8-17/32)
D(Suspension bolt pitch)
E
221(8-23/32)
507(19-31/32)
Terminal bed(Transmission)
20(13/16)
Terminal box
68(2-11/16)
Drain hose
I.D.32mm (1-1/4inch)
<flexible joint >
(accessory)
mm(in.)
Drain hole
20(13/16)
Water filling port
670(26-13/32)
70(2-25/32)
509(20-1/32)
497(19-19/32)
634(24-31/32)
Air filter
146
(5-3/4)
574(22-5/8)(Suspension bolt pitch)
Terminal bed(Power source)
Suspension bolt hole
4-14X30(9/16X1-3/16) Slot
Control box
108
(4-9/32)
34(1-11/32)
110
(4-11/32)
159
(6-9/32)
52(2-1/16)
634(24-31/32)
45(1-25/32)
108
(4-9/32)
(2-3/8)
60
(1-29/32)
48
(1-25/32)
70
146
(2-25/32) (5-3/4)
(67(2-21/32))
68(2-11/16)
3
300(11-13/16) or less
20(13/16)
122
(4-13/16)
190(7-1/2)
670(26-13/32) (Opening dimension)
266(10-1/2)
Note:1.Use M10 screw for the Suspension bolt (field supply).
2.It is available to connect the branch duct
on right and left side both.
3.On Model :18, you would use flare nut when connecting
the Outdoor Unit for R22.
290(11-7/16)
(1-29/32)
574(22-5/8)(Suspension bolt pitch)
48
73 202(7-31/32)
(2-7/8)
710(27-31/32)
More than 350(13-25/32)
(78(3-3/32))
583(22-31/32) Max
development, production, installation and auxiliary services" for products built at
an authorized plant.
20(13/16)
Model:
PLFY-P12NLMU-E – DIMENSIONS
Units: in.(mm)
Mitsubishi Electric Air Conditioning & Refrigeration Systems Wo rks acquired ISO
based on a review of quality warranties for the production of refrigeration and air
conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality warranties as
Mitsubishi Electric Sales Canada Inc.
www.MitsubishiElectric.ca
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental
Specifications are subject to change without notice.
SB_PLFY-P12NLMU-E_201005