SUPPLEMENTAL SERVICE MANUAL
S75M257R530XF
MICROWAVE OVENS
R-530EKF, R-530ESF, R-530EWF,
This is a supplemental Service Manual for Microwave Oven models:
R-530EKF, R-530ESF, and R-530EWF.
These models are quite similar to the base models:
R-530EK, R-530ES, and R-530EW.
This supplemental manual must be used in conjunction with the base model service manual for
complete operation, service, safety and replacement parts information.
This supplemental manual is being issued to comply with the new FCC standards, that all
Microwave models produced from July 2005 must have a noise filter unit included, plus any
associated parts.
In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified
should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor,
High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..)
SHARP ELECTRONCS CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
Service Headquarters: Sharp Plaza, Mahwah, New Jersey, 07430-2135
NEW SCHEMATIC
H
N
120VAC
60Hz
MAGNETRON
TEMP CUTOUT
RED
BLK
RED
B LU
N.O.
COM.
GRN
GND
A2
(RY1)
BLU
BLK
HUMIDITY
SENSOR
(RY2)
F3
POWER
TRANSFORMER
RED
PRIMARY
INTERLOCK
RELAY
A1
F2
WHT
CONTROL UNIT
N.O.
COM.
B2
G RN
MONITOR
SWITCH
FAN
MOTOR
COM
GRY
GRY
ORG
DOOR
SENSING
SWITCH
HIGH
VOLTAGE
RECTIFIER
WHT
WHT
G RY
FM
WHT
B RN
ORG
ORG
GRY
WHT
OVEN
LAMP
TTM
TURN
TABLE
MOTOR
HIGH
VOLTAGE
CAPACITOR
N.C.
N.O.
OL
WHT
PNK
CAVITY
TEMP
FUSE
BLU
B RN
BLU
ORG
B1
WHT
LINE BYPASS CAPACITOR
0.0033 μF 250V
NOISE SUPRESSION COIL
MAGNETRON
LINE BYPASS CAPACITOR
0.0033 μF 250V
RESISTOR 470 k
WHT
N
LINE CROSS CAPACITOR 1.0 μF 275V
FUSE
20A
F1
1/2W
L
N.O. GRY
GRY COM
WHT
WH T
SECONDARY
INTERLOCK
SWITCH
NOISE FILTER
NOTES:
1. Circuits subject to change wtitnhotuice.
2. Terminal with projection or oiptepobslue mark on lamp socket
must be connected to neutral wire.
3. Only certain models use the uatbesohlumidity sensor.
4. Power Transformer top (finisdh)lteearminal must be connected to the
hot (BLU) wire.
CHANGED PARTS
FW-VZB276MRE0
QFS-TA013WRE0
FPWBFA380WRKZ
LANGQB025MRP0
FFS-BA016/KIT
Main wire harness
Main wire harness
Magnetron temp fuse
Noise filter unit
Noise unit angle
Monitor switch (V-16G-2C25) and fuse assembly (20A 250V AC)
Magnetron
temp
fuse
1
1
1
1
1
AX
AE
AM
AE
AF
Monitor switch
and
fuse assembly
Noise filter unit
Noise unit angle
Actual wire harness may be different from illustration.
Monitor switch