Subsidiaries
ARGENTINA
SDMO ARGENTINA S.A.
TEL. +54 11 48363511 - FAX +54 11 48363516
BELGIUM
SDMO NV/SA
TEL. +32 3 646 04 15 - FAX +32 3 646 06 25
BRAZIL
SDMO DO BRAZIL
TEL. +55 (11)4390 8434 - FAX +55 (11)4390 8434
SPAIN
SDMO INDUSTRIES IBERICA
TEL. +34 902 30 56 56 - FAX +34 93 580 31 36
UNITED STATES
SDMO GENERATING SETS
TEL. +1 305 863 00 12 - FAX +1 305 863 97 81
UNITED KINGDOM
SDMO ENERGY LTD
TEL. +44 (0)1932 345 777 - FAX +44 (0)1932 350 033
Offices
DUBAI
SDMO MIDDLE EAST
TEL. + 971 50 294 96 94 - FAX +33 1 722 755 75
Photo credit: SDMO - Guillaume Team
ALGERIA
SDMO ALGER
TEL. +213 21 92 55 84 - FAX +213 21 92 47 76
Power products
NIGERIA
SDMO LAGOS
TEL +234 (0)1 776 95 95 - FAX + 33 (0)1 72 27 55 62
PPRINT/GB-2007/1
4668-10.06.L
���������������
����������������������
SDMO Industries - 12 bis rue de la villeneuve
CS 92 848 - 29 228 Brest Cedex 2 - France
Tel. +33 (0)2 98 41 41 41 - Fax +33 (0)2 98 41 63 07
www.sdmo.com
50HZ 60HZ
7.5kVA - 630kVA
ENGLISH 11kWe - 550kWe
A powerful response
energy required
SDMO is recognised as one of the best manufacturers of
g e n e r a t i n g sets in the world. SDMO has channelled all
its energy into designing a range which is both highly-competitive
and high-performance, the largest range available on the market.
As a response to the increasingly precise nature of your energy
requirements, which relate directly to the special traits of your
particular industry, SDMO is devoting the majority of its resources to
the continuous improvement of its range and services.
whatever the
Whether you require emergency power to be able to cope with potential energy cuts (e.g. hospitals, shopping
centres) or continuous power when conventional electrical grids are faulty (power plants), SDMO will be able to
offer you performance products from a large range which meets all the requirements of different markets.
National coverage,
international presence,
‘‘think globally, act
locally‘‘
In order that SDMO can continue to grow and expand into
new markets, it relies on:
- a distribution network present in over 150 countries,
- 7 overseas subsidiaries,
- its representation offices based in Algeria and Dubai,
- its 7 sales offices and 3 regional divisions in France.
… and 5 storage platforms, which together make for an
efficient commercial network.
The result of a strategy focussed on a single industry: our exacting
professionalism provides you with a reliable source of energy,
complying with the strictest of standards. The pioneering mindset
of their teams, and the mastery and flexibility of their production
methods mean that SDMO is constantly innovating. The proximity of
their distribution network and dynamism of their customer services
policy enable SDMO to be a powerful force and provide the basis
of the company's values.
SDMO, the source of energy for your comfort and safety.
SDMO, providing the energy that links mankind.
��������������������������������������������������������������������������������������������
PPRINT/GB-2007/1
50HZ 60HZ
7.5kVA - 630kVA
11kWe - 550kWe
The SDMO services
department has been
working to optimise
the performances of
products and to ensure
the safety of all.
Technical assistance to ensure the reliability of the
products
So that you are never without energy, now and in the future,
the After-Sales team will respond to any technical question or
difficulty encountered with a generating set from the moment
it is installed, in the shortest time possible.
Spare Parts Department:
an efficient, well-integrated network
Components are delivered as quickly as possible at the best
prices.
Training to produce better levels of response
The means to acquire and update their knowledge .
Power Products from 33 kVA to 440kVA
Power Products from 7.5 kVA to 44kVA
50HZ 60HZ
MONTANA
J 100U
4
PACIFIC
T 11.5K TELYS control unit optional
THREE PHASE GENERATING SETS
TECHNICAL SPECIFICATIONS
Specifications 50 Hz
400-230 V
GENSETS
(1)
kVA
Cos 0.8
PRP
(3)
Specifications 60 Hz
480-277 V
kWe
ISO 8528*
ESP
(4)
PACIFIC
T 30U TELYS control unit optional
Cons GENSETS
3/4
(2)
PRP
L/h
(3)
ESP
(4)
Cons
3/4
L/h
Engine
Engine
type
cyl
Bore
(mm)
Stroke
(mm)
Cyl
(L)
Type
J30U
25
28
8.4
J40U
36
12
J60U
55
77
12
J70U
88
14
J80U
100
110
16.5
120
132
18.5
J165K
150
165
J200K
180
198
ESP
J33
30
33
5.2
J44K
40
44
J66K
60
66
J77K
70
J88K
80
J110K
J130K
(3)
Tank
(L)
T15 HK
-
15
4.2
-
-
-
-
L3E SDH
3L
76
70
0.95
FT2MBS
1.41x0.72x1.03
294
50
T20 HK
-
20
5.5
-
-
-
-
S3L2 SDH
3L
78
92
1.3
ECO3-2L
1.41x0.72x1.05
386
50
T27 HK
-
27
6.3
-
-
-
-
S4L2SDH
4L
78
92
1.8
ECO28-2L
1.70x0.90x1.12
530
100
T7.5K
6.8
7.5
1.7
-
-
-
-
L3 E SD
3L
76
70
1.00
ECO3-2S
1.41x0.72x1.03
307
50
T11.5K
10.5
11.5
2.5
T11U
10
11
3.2
S3L2 SD
3L
78
92
1.318
ECO3-1L
1.41x0.72x1.05
387
50
T16K
14.5
16
3.4
T16U
15
16
4.2
S4L2 SD
4L
78
92
1.758
ECO3-2L
1.41x0.72x1.05
406
50
kWe
ISO 8528*
ESP
PRP
(5)
Weights(6)
(kg)
Cons GENSETS
3/4
(2)
L/h
(4)
MONTANA RANGE
General specifications
PRP
(1)
Dimensions
lxwxh (m)
kVA
Cos 0.8
Specifications 60 Hz
480-277 V
Cons
3/4
L/h
GENSETS
Compact Version
Alternator
THREE PHASE GENERATING SETS
TECHNICAL SPECIFICATIONS
PACIFIC RANGE
General specifications
MONTANA
J 200K
TELYS control unit optional
Specifications 50 Hz
400-230 V
50HZ 60HZ
Engine
Alternator
Compact Version(5)
Engine
type
cyl
Bore
(mm)
Stroke
(mm)
Cyl
(L)
Type
Dimension
lxwxh (m)
Weights(6)
(kgs)
Tank
(L)
6.3
3029DF120
3L
106
110
2.9
ECO28VL
1.70x0.89x1.22
740
100
40
10.1
3029TF120
3L
106
110
2.9
ECO32-3S
1.70x0.89x1.22
820
100
60
14.5
4045TF120
4L
106
127
4.5
432M45
1.87x0.99x1.36
1000
180
64
70
14.5
4045TF120
4L
106
127
4.5
432L65
1.87x0.99x1.36
1110
180
73
80
16
4045TF220
4L
106
127
4.5
432L8
1.87x0.99x1.36
1110
180
J100U
91
100
19
4045HF120
4L
106
127
4.5
442VS45
1.95x1.08x1.33
1240
190
J120U
106
117
24
6068TF220
6L
106
127
6.7
442S7
2.37x1.11x1.48
1570
340
25
J150U
137
150
29
6068HF120-153
6L
106
127
6.7
442M95
2.37x1.11x1.48
1640
340
31.3
J175U
159
175
36.1
6068HF120-183
6L
106
127
6.7
462M3
2.37x1.11x1.48
1730
340
J200U
182
200
36.9
6068HF475
6L
106
127
6.7
462M5
2.37x1.11x1.48
1790
340
6081HF001
6L
116
129
8.1
462L6
2.90x1.30x1.70
2170
390
(3)
(4)
T22K
20
22
4.7
T20U
18
20
5.6
S4 Q2 SD
4L
88
103
2.5
ECO28-1L
1.70x0.90x1.12
560
100
T33K
30
33
6
T30U
27
30
8.2
S4S SD
4L
94
120
3.3
ECO28VL
1.70x0.90x1.14
660
100
J220K
200
220
32.6
T44K
40
44
7.3
T40U
36
40
8.7
S4S DT
4L
94
120
3.33
ECO32-3S
1.70x0.90x1.16
680
100
J275K
250
275
40.1
-
-
-
-
J300K
275
303
42.6
J250U
227
250
46.1
6081HF001
6L
116
129
8.1
462L9
2.90x1.30x1.68
2235
390
J400K
365
402
59.4
J350U
318
350
76
6125HF070
6L
127
165
12.5
472VS2
3.16x1.34x1.79
3090
470
J440K
400
440
59.4
J400U
363
400
76
6125HF070
6L
127
165
12.5
472VS3
3.16x1.34x1.79
3120
470
SINGLE PHASE GENERATING SETS
TECHNICAL SPECIFICATIONS
Specifications 50 Hz
230 V
kVA
Cos 0.8
Specifications 60 Hz
240 V
kWe
ISO 8528*
PRP
ESP
-
-
-
1.7
-
-
8.6
2.5
T11UM
11
12.1
3.4
T17KM
15.6
17.2
-
-
-
GENSETS
Cons
3/4 GENSETS
L/h
General specifications
Cons
3/4
L/h
(7)
PRP
ESP
T11.5HKM
-
11.5
4.2
T5.5KM
5
5.5
T9KM
7.8
T12KM
(3)
(4)
PACIFIC RANGE
Engine
Alternator
cyl
Bore
(mm)
Stroke
(mm)
Cyl
(L)
Type
Dimensions
lxwxh (m)
Weights(6)
(kg)
Tank
(L)
-
L3E SDH
3L
76
70
0.95
ECO3-2L
1.41x0.72x1.03
318
50
-
-
L3E SD
3L
76
70
0.95
ECO3-2S
1.41x0.72x1.03
307
50
9.1
10
3.2
S3L2 SD
3L
78
92
1.30
ECO3-2L
1.41x0.72x1.05
396
50
T16UM
14
15
4.2
S4L2 SD
4L
78
92
1.75
ECO28-1L
1.41x0.72x1.05
452
50
J24M
4.7
T20UM
18
20
5.6
S4Q2 SD
4L
88
103
2.50
ECO28VL
1.70x0.90x1.12
580
100
-
T30UM
27
30
8.2
S4S SD
4L
94
120
3.33
ECO28VL
1.70x0.90x1.14
660
100
(4)
(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V
(2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V
(3)PRP: Prime power in direct current for an unlimited number of annual operating hours in variable load
applications, in accordance with ISO 8528-1, a 10% overload capacity is available for a period of 1 hour
every 12-hour period of operation, in accordance with ISO 3046-1
(4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in
accordance with ISO 8528-1, no overload available for this service.
(5)The dimensions and weights apply to a generating set specified in the price list, without
options
(6)Dry weight - without fuel
(7)Also available in the following voltages: 220 V - 240 V
*ISO 8528: powers specified in compliance with the legislation in force
Specifications 60 Hz
240 V
Specifications 50 Hz
230 V
Engine
type
(3)
SINGLE PHASE GENERATING SETS
TECHNICAL SPECIFICATIONS
Compact Version(5)
GENSETS
(7)
kVA
Cos 0.8
Cons GENSETS
3/4
L/h
PRP
ESP
J30UM
25
28
-
J40UM
36
-
J70UM
64
ESP
22
24
5.2
-
-
-
-
-
-
(4)
General specifications
Cons
3/4
L/h
PRP
(3)
kWe
ISO 8528*
(3)
MONTANA RANGE
Engine
Alternator
Compact Version(5)
Engine
type
cyl
Bore
(mm)
Stroke
(mm)
Cyl
(L)
Type
Dimensions
lxwxh (m)
Weights(6)
(kg)
Tank
(L)
6.3
3029DF120
3L
106
110
2.9
ECO32-3S
1.70x0.89x1.22
800
100
40
10.1
3029TF120
3L
106
110
2.9
432M45
1.70x0.89x1.22
860
100
70
14.5
4045TF120
4L
106
127
4.5
442VS45
1.87x0.99x1.36
1150
190
(4)
(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V
(2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V
(3)PRP: Prime power in direct current for an unlimited number of annual operating hours in variable load
applications, in accordance with ISO 8528-1, a 10% overload capacity is available for a period of 1 hour
every 12-hour period of operation, in accordance with ISO 3046-1
(4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in
accordance with ISO 8528-1, no overload available for this service
(5)The dimensions and weights apply to a generating set specified in the price list, without options
(6)Dry weight - without fuel
(7)Also available in the following voltages: 220 V - 240 V
*ISO 8528: powers specified in compliance with the legislation in force
Power Products from 220 kVA to 700kVA
50HZ 60HZ
basic and options
50HZ 60HZ
EQUIPMENT
basic and options
PACIFIC
Basic and options
SDMO
engine
cooling
exhaust
6
Alternator
Resistance calculation,
modal analysis of vibration frequencies, study
of the sound intensity
measurement… this is
the type of technology
our engineers have at
their disposal when
designing our products
and guaranteeing
they comply with
international standards.
ATLANTIC
V 400U
generating set
PLUS
4 stroke water-cooled diesel engine
Mechanical adjustment
Electronic adjustment
Standard air filter
Air filter with interchangeable cartridge
220/240 V preheating resistor
Control and interface unit (CIU)
Single bearing alternator IP 23, T° class =H, insulation class H
Anti condensation resistor
Reinforced insulation
Synchronizing CT coupling + 3 function regulator
AREP excitation
PMG + Regulator
CE compliance of the control unit
Protective grille for hot parts
CSA NRTL/C compliance
Power circuit breaker
Mechanically welded chassis with antivibration suspension
Supplied in colour RAL 9005/5007 (black/blue) delivered in shrink-wrap film
Supplied with oil and coolant -30°C
Oil drain tap + diesel or gas pipe
Oil drainage pump
9 dB(A) silencer supplied separately
9 dB(A) silencer not supplied
Adaptable 9 dB(A) silencer (not compatible with CEL 02)
29 dB(A) silencer supplied separately
40 dB(A) silencer supplied separately
40 cm extension piece
Compensator with brackets or pipe
Manifold protective grille (mandatory for CE)
Radiator for max wiring harness T° 50°C with drain tap (depending on model)
Supplied without coolant
Protective grille for fan and rotating parts
Radiator wiring harness protective grille
Charging alternator and starter
Batteries with cables and battery mounting
No battery or battery mounting (cables are supplied)
Battery isolating switch
Tank integrated into the chassis
High autonomy double wall chassis
Diesel outlet not connected (no tank)
Automatic power supply kit for chassis tank
Automatic power supply for separate tank
1 or 2 pump automatic kit
Fluid recovery tank
Bulk tank on DT
Diesel separator pre-filter
Separate tank on 500 L tank
Separate tank on 1000 L tank
Bulk tank level alarm for separate tank (5)
User manual and commissioning guide (Paper version) - French, English or Spanish
User manual and commissioning guide (Paper version) - French, English or Spanish(4)
User manual and commissioning guide (CD version) - French, English or Spanish
Engine parts catalogue (paper version) - English
Engine parts catalogue (CD version) - English
Engine repair and workshop manual (paper version) - English
Engine repair and workshop manual (CD version) - English
Standard tool kit
Standard tool chest
GENSERVICE 500 spare parts
GENSERVICE 1000 spare parts
level
PRODUCT
diesel
starting
ATLANTIC
V 630K
THREE PHASE GENERATING SETS
TECHNICAL SPECIFICATIONS
Specifications 60 Hz
480-227 V
kVA
Cos 0.8
kWe
ISO 8528*
PRP
ESP
Cons
3/4
L/h
V220K
200
220
32.5
V275K**
250
275
V330K
300
330
V375K
340
375
50.6
-
-
-
-
-
-
-
V350U
319
350
V410K
375
413
55
-
-
-
V440K
400
440
59.5
V400U
364
400
V500K
450
500
69.2
V450U
400
450
V550K
500
550
75.4
V500UC2
455
500
V630K
570
630
85
-
-
-
-
-
-
V550UC2
V700K**
630
700
94.5
V600UC2**
GENSETS
(1)
(3)
(4)
General specifications
PRP
ESP
Cons
3/4
L/h
V200U
182
200
42.6
V250U**
227
50.6
V300U
273
GENSETS
(2)
Engine
Alternator
Compact Version(5)
Engine
type
cyl
Bore
(mm)
Stroke
(mm)
Cyl
(L)
Type
Dimensions
lxwxh (m)
Weights(6)
(kg)
Tank
(L)
36.5
TAD733GE
6L
108
130
7.2
462M5
2.37x1.11x1.54
1850
340
250
45.7
TAD734GE
6L
108
130
7.15
462L6
NA
NA
390
300
52.8
TAD941GE
6L
120
138
9.4
462VL12
3.16x1.34x1.76
2850
470
-
TAD941GE
6L
120
138
9.4
472VS2
3.16x1.34x1.76
2780
470
58.5
TAD1241GE
6L
131
150
12.1
472VS2
3.16x1.34x1.80
2900
470
-
TAD1241GE
6L
131
150
12.1
472VS3
3.16x1.34x1.81
3190
470
67.8
TAD1242GE
6L
131
150
12.1
472VS3
3.16x1.34x1.81
3238
470
78.39
TAD1640GE
6L
144
165
16.1
472S5
3.47x1.63x2.04
3490
500
88.79
TAD1641GE
6L
144
165
16.1
472M7
3.47x1.63x2.04
3620
500
-
-
TAD1642GE
6L
144
165
16.1
472L9
3.47x1.63x2.08
3780
610
500
550
97.07
TAD1642GE
6L
144
165
16.1
472M7
3.47x1.63x2.08,
3650
610
545
600
105.7
TAD1643GE
6L
144
165
16.1
491S4
NA
NA
610
(3)
(4)
(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V
(2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V
(3)PRP: Prime power in direct current for an unlimited number of annual operating hours in variable load
applications, in accordance with ISO 8528-1, a 10% overload capacity is available for a period of 1 hour
every 12-hour period of operation, in accordance with ISO 3046-1
(4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications
in accordance with
I
SO 8528-1, no overload available for this service.
(5)The dimensions and weights apply to a generating set specified in the price list, without
options
(6)Dry weight - without fuel
* ISO 8528: powers specified in compliance with the legislation in force
** Available 2007, 2nd trimester
NA Not available
accessories
Specifications 50 Hz
400-230 V
ATLANTIC RANGE
1
•
X
O
AD 21
battery isolating
switch (EN16)
As standard
Not possible
Several possible options - please consult us
Option code
MONTANA
J60U/66/
T12/16/17
J24M
J120U/130 J200U/220
70U/77
T11U/11.5/15H/20H
T20U/22
T40U/44 J30U/33
J150U/165 J250U/275
J80U/88
T5.5/7.5/ 9/ 11.5
T27H/30U/33
J40U/44
J175U/200
J300
J100U/110
2
•
•
x
•
x
EN 20
x
•
x
x
x
x
x
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
x
•
x
FD 05
FD 06
x
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
2
1
3
4
protective grille
for hot parts (CEL02)
FD 01
(1)
(2)
(3)
•
•
EN 01(1)
•
EN 02(2)
EN 20
x
•
x
x
x
x
x
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
x
•
x
FD 05
FD 06
x
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
3
Free option
Not possible on T12, T16
Not possible on T12, T16UM
12V for V220K and V200U
•
•
EN 01
•
EN 02
EN 20
x
•
x
x
x
x
x
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
x
•
x
FD 05
FD 06
x
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
•
•
EN 01
•
EN 02
EN 20
x
•
x
x
x
x
x
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
FD 09
•
x
FD 05
FD 06
x
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
•
•
EN 01
•
EN 02
EN 20
x
•
AL 01
AL 05
x
AL 11
AL 12
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
FD 09
•
x
FD 05
FD 06
x
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
•
•
EN 01
•
EN 02
EN 20
x
•
AL 01
AL 05
o(5)
AL 11
AL 12
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
EN 12
EN 08
EN 09
EN 13
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
FD 09
x
FD 04
FD 05
FD 06
FD 07
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
•
•
EN 01
•
EN 02
EN 20
x
•
AL 01
AL 05
o
AL11
AL 12
•
CEL 02
CEL 03
•
•
•
•
•
EN 04
•
EN 07
x
EN 08
EN 09
x
EN 10
CEL 02
•
FD 11
•
EN 14
12V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
FD 09
x
FD 04
FD 05
FD 06
FD 07
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
J350
J400
J440
ATLANTIC
•
x
•
•
EN 02
EN 20
x
•
AL 01
AL 05
o
AL 11
AL 12
•
CEL 02
CEL 03
•
•
•
•
•
EN 05
•
EN 07
x
EN 08
EN 09
x
EN 10
CEL 02
•
FD 11
•
EN 14
24V
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
FD 09
x
FD 04
FD 05
FD 06
FD 07
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
•
x
•
•
EN 02
EN 20
EN 22(6)
•
AL 01
AL 05
o
AL11
AL 12
•
CEL 02
CEL 03
•
•
•
•
•
EN 05
•
EN 07
x
EN 08
EN 09
x
EN 10
CEL 02
•
FD 11
•
EN 14
24V1(3)
•
EN 15
EN 16
•
FD 02
FD 01
FD 15
FD 08
o
x
FD 04
FD 05
FD 06
FD 07
FD 14
•
AD 21(4)
AD 22
AD 31
AD 32
AD 41
AD 42
AD 05
AD 06
SP 01
SP 02
4
user manual
and commissioning guide (AD21)
diesel separator
pre-filter (FD05)
(4)
(5)
(6)
Additional copy
Not possible on J130K and J165K
Not possible on V220K and V200U
Enclosures
Generating
sets
MONTANA
ATLANTIC
SDMO
8
PRODUCT
PLUS
M229 ENCLOSURE
Generating
sets
MONTANA
M127 ENCLOSURE
M128 ENCLOSURE
M126 ENCLOSURE
LWA
dB(A)@1m
dB(A)@7m
86
86.1
96
87
96
87
97
90
91
91
90
92
92
92
94
96
91
95
95
95
95
96
96
96.6
NA
97
97
96
96
97
97
100
NA
70.1
70.4
80.8
70.7
80.8
71
81
73
71.1
74.9
73.4
75.6
75.6
79.5
77
77.6
78.6
79.4
78.6
79.5
79.5
76.2
76.3
78.5
NA
77.2
77.2
79.7
79.7
77.6
78.1
81.8
NA
60.1
60.4
70.8
60.7
70.8
61
71
63
61.1
65
63
66
66
70
67
67.6
68.8
69
68.6
69.5
69.5
66.5
66.6
68.5
NA
67
67
70
70
68
68
71.5
NA
Specifications 60 Hz
Generating
dB(A)@7m
sets
T11U
T16U
T20U
T30U
T40U
J30U
J40U
J60U
J70U
J80U
J100U
J120U
J150U
J175U
J200U
J250U
J350U
J400U
V200U
V250U*
V300U
V350U
V400U
V450UC
V500UC2
V550UC2
V600UC2*
Specifications 50 Hz
T5.5KM
T9KM
T11.5HKM
T12KM
T17KM
J24M
**
LWA
dB(A)@1m
dB(A)@7m
62.5
64
65.4
66.3
69.2
67.6
67
66
67
73.1
70
68.9
68.9
68.9
70.1
72.5
71
71
71.7
NA
69.9
73
73
73.8
75
75.4
NA
86
86
96
87
87
91
-
70.1
70.4
80.8
70.7
71
74.9
-
60.1
60.4
70.8
60.7
61
65
-
Available 2007, 2nd trimester
(1)
Specifications 60 Hz
Generating
dB(A)@7m
sets
T11UM
T16UM
T20UM
T30UM
J30UM
J40UM
J70UM
Net weight without fuel
M126
M126
M126
M126
M126
M127
M127
M127
M127
M127
M127
M128
M128
M128
M129
M226
M226
M226
M226
M227
M227
M228
M228
M226
M227
M228
M228
M228
M228
M229
M229
M230
M230
50
50
50
50
50
100
100
100
100
100
100
180
180
180
190
340
340
340
340
390
390
470
470
340
390
470
470
470
470
500
500
610
610
Enclosure
Tank (L)
M126
M126
M126
M126
M127
M127
M127
M127
M129
50
50
50
50
100
100
100
100
190
62.5
64
65.4
66.3
67.6
67
67
NA
Weight(1) (kg)
1.75x0.72x1.23
1.75x0.72x1.23
1.75x0.72x1.23
1.75x0.72x1.23
1.75x0.72x1.23
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.30x1.08x1.68
2.30x1.08x1.68
2.30x1.08x1.68
2.55x1.17x1.68
3.51x1.20x1.83
3.51x1.20x1.83
3.51x1.20x1.83
3.51x1.20x1.83
4.00x1.38x2.13
4.00x1.38x2.13
4.48x1.41x2.43
4.48x1.41x2.43
3.51x1.20x1.83
4.00x1.38x2.13
4.48x1.41x2.43
4.48x1.41x2.43
4.48x1.41x2.43
4.48x1.41x2.43
5.03x1.56x2.44
5.03x1.56x2.44
5.03x1.69x2.66
5.03x1.69x2.66
455
535
442
554
534
790
752
890
920
970
1040
1410
1530
1530
1640
2160
2230
2320
2390
3150
3215
4220
4250
2490
NA
3980
3910
4320/4020
4320
4740
4870/5170
5300
NA
9
Assembled soundproofing enclosure
Non-assembled soundproofing enclosure (supplied as a kit) (1)
Black/Blue (RAL 9005/RAL 5007)
Special colour application, to replace RAL 5007 (lead time 8 weeks)
Electrogalvanised steel panels before paint application protected
by a rust-resistant polyester paint powder
General
Specifications Bichromate galvanized bolting and stainless steel rivets, polyamide or anodised aluminium alloy hinges, seals provided
by flexible joints between the bodywork components
Soundproofing foam between 20 and 50 mm thick
Bulk tank on daily service tank
Fluid recovery tank
High autonomy double wall chassis
Lockable doors with a unique key
Lockable control unit porthole
Emergency stop button fitted on outside of enclosure
Access to diesel, oil and battery behind lockable doors
Safety
Protective grille for rotating parts
Exhaust integrated into the enclosure
Galvanised metal air emission sleeve
Remote connection terminal block for armoured cables
Socket kit (400 V Three phase + N) (2)
Lifting ring (number of points)
Handling
Single base panel
Access doors on each side (number)
Maintenance
Oil drainage pump
Electric control unit accessible via a door
Road trailer with fixed drawbar and ball attachment
Road trailer with hinged drawbar and ring attachment 68x42
40 mm eye (DIN German)
Trailers(3)
76 mm eye (NATO)
50 mm ball (universal)
Spare wheel kit
M226 ENCLOSURE
M129 ENCLOSURE
M230 ENCLOSURE
M227 ENCLOSURE
M228 ENCLOSURE
•
X
As standard
Not possible
CN 08
Option code
TR 21
(1)
General specifications
Dimensions
L x w x h (m)
Weight(1) (kg)
1.75x0.72x1.23
1.75x0.72x1.23
1.75x0.72x1.23
1.75x0.72x1.23
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.08x0.96x1.42
2.55x1.17x1.68
455
544
466
600
810
940
1020
1090
1550
Not available
EQUIPMENT
BASE AND OPTIONS
All SDMO generating sets are compliant with directive 2000/14/CE
and its products are checked and validated by an approved laboratory, CETIM.
Enclosure
General specifications
Dimensions
Tank (L)
L x w x h (m)
SINGLE PHASE
PACIFIC
The new design of our modular
soundproofing enclosures
will allow you to make savings in
both costs and space!
Specifications 50 Hz
T7.5K
T11.5K
T15HK
T16K
T20HK
T22K
T27HK
T33K
T44K
J33
J44K
J66K
J77K
J88K
J110K
J130K
J165K
J200K
J220K
J275K
J300K
J400K
J440K
V220K
V275K*
V330K
V375K
V410K
V440K
V500K
V550K
V630K
V700K*
PACIFIC
50HZ 60HZ
GENERATING SETS & ENCLOSURES
THREE PHASE
Free option
This option is only available to persons who
have received the requisite training
SiM
SiK
•
CN 08
M127
M128
M129
SiM
SiK
•
CN 08
SiM
x
•
CN 08
M227
M228
M229
SiM
x
•
CN 08
SiM
x
•
CN 08
•
•
•
•
•
•
•
•
•
•
•
x
•
FD 02
•
•
•
•
•
•
CN 03
CN 06
CN 04
1
x
2+1
EN 04
•
TR 10
TR 11
TR 21
TR 25
TR 26
TR 31
•
x
•
FD 02
•
•
•
•
•
•
CN 03
CN 06
CN 04
1
x
2+1
EN 04
•
x
TR 11
TR 21
TR 25
TR 26
TR 31
•
FD 04
x
FD 02
•
•
•
•
•
•
CN 03
CN 06
x
1
CN05
2+2
EN 04
•
x
TR 11
TR 21
TR 25
TR 26
TR 31
•
FD 04
x
FD 02
•
•
•
•
•
•
CN 03
CN 06
x
2
CN05
2+2
EN 04
•
x
x
x
x
x
x
•
FD 04
x
FD 02
•
•
•
•
•
•
CN 03
x
x
M126
(2)
(3)
M226
M230
CN05
2+2
EN 06
•
x
x
x
x
x
x
Requires differential protection
For M127 to M226 enclosures in Europe,
consult the RENTAL POWER 2007 documentation
electrical control units
50HZ 60HZ
MICS TELYS
SPECIFICATIONS
The new generation of Telys, SDMO's flagship product, integrates all the features of the
previous version, whilst including certain improvements and additions. It is even more
straightforward and user-friendly, with the emphasis on communication (USB connections,
PC connections, control software and remote operation).
Emergency stop
push button
- Built-in fault finding tool guiding the user
in the event of any alarms or faults
- Ability to send(b) e-mail, SMS or fax in the event of any
alarms or faults
- Genset or temporary coupling card as an option (a)
- Optional tropicalisation of the cards to provide protection
in extremely humid conditions (b)
Alarm LEDs
Fault LEDs
Genset start button
Telys "live" LED
Speed/voltage trimming
Power on
Fuel solenoid valve control
Starter control
Preheating plug
Water preheating
Network switch (normal)
Network switch (emergency)
O
●
●
●
O
O
O(1)
O(1)
Oil pressure fault
Coolant temperature fault
Non-starting fault
Overspeed fault
Genset ready to supply
Charging alternator fault
General alarm
General fault
Panel light
STOP, MANU, AUTO, TEST modes
Generating set switch closed (normal)
Network switch closed (emergency)
All alarm and/or fault messages
●
●
●
●
●
●
●
●
●
●
O(1)
O(1)
● LCD
Measurements
● LCD
● LCD
● LCD
ESCAPE button
ON/OFF key
Protection fuse
- Compliance with various legal requirements
or regulations (CE, UL, etc.)
Genset stop
button
- Screen with contrast adapted to all types of lighting
Menu access
button
(a) available from 2007 semester 1
(b) As an option
Oil pressure fault
Coolant temperature fault
Emergency stop fault
Short circuit or overload fault or alarm
Battery voltage min/max fault or alarm
Alternator voltage min/max fault or alarm
Alternator frequency min/max fault or alarm
Overspeed fault
Presence of differential relay fault
Differential relay triggered alarm or fault
●
●
●
●(2)
●(2)
●(2)
●(2)
●
O(3)
O(2=3)
Automatic standby
Automatic shutdown
4 modes
Engine stop for auto cooling
Speed and voltage stabilisation
Preheating plug
Registering retro-information from the normal/emergency switch
Switch from emergency to normal
Switch from normal to emergency
Manual closure of the generating set switch
Manual opening of the generating set switch
Starting on clock
Remote starting order
Three phase mains detection
●
●
●
●
●
O
O(1)
O(1)
O(1)
O(1)
O(1)
O(1)
O(1)
O(4)
Light test
Fault reset
Prewiring for auto-startup
Automatic pack
(charger+relay and engine preheater resistor)
GES pack(5) fitted on the genset(6)
NFPA 110 module (60 Hz)
Adjustable differential protection (time and threshold)
Sound alarm
●
●
O
Scrolling and
selecting wheel
TELYS
IN
Display screen made up of 4 zones:
ZONE 1: Operation mode
(genset running/auto/manual)
FIGURES
ZONE 2: Display of functions via
pictograms
Operation at
-20°C to +60°C
Hygrometry:
95% at 45°, 70% at 50°C,
50% at 60°C
5 language options,
numerous optional
languages
Ability to connect
up to 5 additional input/
output modules
(4 inputs/6 outputs) (b)
ZONE 3: Display of mechanical and
electrical values and the associated
measurements
ZONE 4 : Operating messages and
parameter settings menu
(1) Control and automatic operation present, but require the "Prewiring for auto-startup" option
and possibly the configuration of a parameter on the mics TELYS
(2) The choice of alarm or fault is made by programming on the keyboard
(3) Differential protection is ensured by an exterior module
(4) Mics DS detection is provided using the source changeover switch as a base.
If the source changeover switch is not chosen, the Mics DS module can be fitted in the control unit
(5) To find out more detailed contents, please consult us
(6) Standard NFE37312
O Option
● Standard
● LCD
11
Safety
10
2 USB ports
under a sealed
cover
Engine speed indicator
Battery voltage indicator
Working hours counter
● LCD
O
O
Automatic functions
- Integrated maintenance monitoring programme(a)
(on-screen display of future maintenance operations)
The USB ports facilitate
daily
maintenance or
product updates,
enabling the
configuration
parameters
to be saved
(Telys -> USB key) or,
alternately, the software
to be updated (USB key
-> Telys).
Engine
parameters
PLUS
Its new design, inspired by the NEXYS, has reduced the number of buttons to offer you simplicity when
operating your generating set. It also offers the following
new features:
● LCD
● LCD
● LCD
● LCD
● LCD
● LCD
Controls
PRODUCT
Powers (active, reactive)
Composite voltages
Single voltages
Phase current
Neutral current
Frequency
All states of the generating set,
all starting phases
Analog indicator
Battery ammeter
Indicator lights and/or messages
SDMO
Accessories
PRESENTATION
50HZ 60HZ
Standard with LCD message
For more information on the TELYS, please refer the TELYS documentation (TEL/GB-2007) or speak to your SDMO sales representative
O
O
O
O(2)
O
electrical control units
50HZ 60HZ
NEXYS
TYPES OF CONTROL UNIT
TELYS
KERYS
Pacific
X
X
X
X
Montana (J33 to J300)
Montana (J400 to J440)
X
Atlantic (V200U-V220K)
Atlantic (> V220)
X
MICS NEXYS
PRESENTATION
The Mics NEXYS, SDMO's new entry-level control unit, enables operation in both manual and automatic mode. Modular in design,
it offers high-quality basic functions, allowing easy and reliable operation of your generating set.
Indicator LEDS
LCD display
Panel light
PRESENTATION
MICS KERYS
50HZ 60HZ
The Mics KERYS is a user-friendly, easy to grasp tool, offering a wide range of functions. It is fitted as standard to all generating
sets designed for coupling applications, and can be fitted as an option, from 200 kVA, to the rest of our applications. So that all
the requirements of high and low voltage power plants can be met, the Mics KERYS can be built into the console, fitted directly
onto the generating set or on a separate cabinet. It complies with CE, UL and CSA standards.
Control keypad
with display LEDs
Display screen
7.4 inch LCD TFT
Selecting manual mode
Colour graphic display
Selecting stop mode
Touch screen
Selecting automatic mode
Dimensions:
Opening/closing the genset
154 mm x 86 mm
circuit breaker
Activating/deactivating the test
Parameter setting keypad
Opening/closing the grid
For setting parameters,
circuit breaker
navigating and directly
LED test
accessing the screens
Stop horn
Fault clearance
13
12
Directional keypad
with LED showing activity
Emergency stop
button
The Mics KERYS is available in two versions. The basic MMI (Man/Machine Interface) includes a monochrome LCD screen with a
functions keypad. The top of the range version of the Mics KERYS Tactil has a TFT colour touch screen. Both of these two versions has an
ergonomic interface for configuration, operation or fault finding.
Location
of options
ON/OFF key
switch
Protection
fuse
ADDITIONAL SPECIFICATIONS
Scrolling display button / Genset stop button / Genset start button
● LCD
● LCD
● LCD
●
●
O
O
Oil pressure fault
Water temperature fault
Non-starting fault
Overspeed fault(1)
Genset ready to supply
Charging alternator fault
General alarm
General fault
Panel light
Emergency stop fault
●
●
●
O
●
●
●
●
●
●
O
Option
●
Standard
● LCD Standard with LCD message
Safety
Engine parameters
Engine speed indicator
Battery voltage indicator
Working hours counter
Fuel solenoid valve control
Starter control
Preheating plug
Water preheating
Overload or short circuit fault
Overspeed fault(1)
Differential relay triggered fault
Automatic standby
O
O
O
●
Automatic functions
O
O
O
● LCD
O
Speed and voltage stabilisation
Preheating plug
Switch from normal to emergency
Switch from normal to emergency
Remote start order
Three phase mains detection
Light test
●
O
Accessories
Measurements
Composite voltages(1)
Single voltages(1)
Phase current(1)
Frequency
Analog indicator(1)
Indicator lights and/or messages
SPECIFICATIONS
Fault reset
Prewiring for auto-startup
Regulated 12V battery charger
Adjustable differential protection (time and threshold)
Sound alarm
Permanent isolation controller
(1)
(2)
(3)
(4)
O(2)
O(2)
O
O(3)
●
●
O
O
O
O
O
Measurements
Power factor in the different screens
Active and reactive powers
Synchronism (difference in phase, voltage and
frequency)
Harmonics in voltage and current
Safety features
Overload, short circuit
Phase current direction
Neutral current
Reverse component
Voltage reserve
Thermal image
Presence and absence of voltage
Maximum active power
Active and reactive power return
Homo-polar current and homo-polar current
direction
Restricted earth and homo-polar voltage
Vector jump, min Z and df/dt
Synchronisation
Manual and automatic
Frequency and voltage equalisation
Adjustment
Speed and voltage
Switching frequency and voltage set values
Adjusting frequency and voltage set values
Adjusting active and reactive power set values
Active and reactive power surge keyway
Active and reactive power distribution
Active and reactive power return setting
Manual control of speed and voltage regulations
Communication
In local mode or remote mode
Built-in Web server
Via RS485 connection
Via Ethernet (in local mode) and Internet (in
remote mode)
Plus points integrated as standard
Fault finding aid
Assistance and maintenance (history, sending
of emails...)
Mechanical and electrical parameter archives
and curves
Load impact management
Addition of supplementary software without
external tool
As standard on MONTANA and ATLANTIC generating sets
If normal/emergency switch with TSI
Standard in the normal/emergency switch with TSI
The choice is reviewed via programming. Modification of the voltage reference wiring
For more information on the MICS NEXYS, please refer the NEXYS documentation (NEX/GB-2006/1)
or speak to your SDMO sales representative
* For more information, please refer to the Mics KERYS documentation
or speak to your SDMO sales representative.
Configurations
A612: Genset without grid
A622: Genset with normal/emergency switch
and grid without coupling
A633: Production plant without grid
A634: Production plant with grid and normal/
emergency switch (no grid coupling)
A641: Genset with permanent coupling
to grid without normal/emergency switch Grid coupling + resale
A642: Genset with permanent coupling to grid
without normal/emergency switch Grid coupling + power level 0 kW on the grid
A651: Genset with temporary coupling to grid
and normal/emergency switch
A661: Genset with permanent coupling to grid
and normal/emergency switch
REMOTE OPERATION AND CONTROL
Display
screen
for electrical
data
The Mics KERYS and KERYS Tactil are supplied as standard
with integrated operational software. The
60 resident screens enable you to have complete
control over your installation, regardless of the
distance (operation and parameter setting).
power modules
50HZ 60HZ
CONSOLES AND AIPR
SPECIFICATIONS
Power modules in the console
Up to 630A, the power modules are integrated into the
consoles*. The extra-flexible cables between the console
and the alternator are fitted in a corrugated insulating
sleeve.
POWER OUTPUT
Modular circuit breaker or fixed
unit from 10A to 125A
Fixed unit circuit breaker
160A to 630A
3 poles
X
4 poles
SDMO provides a complete range of separate Normal/Emergency Switches. There are a large number of benefits to our technology,
both in terms of cost and of ease of installation. The design of the control units and boxes enables even cables with large cross
sections to be easily connected. The front panel of the unit no longer opens on just one side, like a conventional control unit,
but on three sides, allowing total access to all the connections for the power equipment and terminal blocks. All our control units
are either three-pole or four-pole. The TSI module (Transfer Switch Intelligence) is fitted as standard to our entire range of normal/
emergency switches, whatever the rating of their switching component (from 25A to 3200A).
(1)
Voltage
Changeover
* When the motorised control option is selected,
the Power module is positioned in AIPR
(1) As standard for some neutral connections
• Standard
O Option
X Not possible
NORMAL/EMERGENCY SWITCH
PRESENTATION
Dimensions
25A
32A
45A
63A
110A
140A
200A
250A
400A
630A
208-440V
•
•
•
•
•
•
•
•
•
•
800A 1000A 1600A 2000A(1)
•
•
•
•
2500A(1)
3150A(1)
•
•
By switches
•
•
•
•
•
•
•
x
x
x
x
x
x
x
x
x
By changeover switches
x
x
x
x
x
x
x
•
•
•
•
•
•
•
•
•
Heights (mm)
500
500
500
500
500
500
600
800
800
800
1000
1000
1000
1800(2)
1800(2)
1800(2)
Width (mm)
430
430
430
430
430
430
600
600
600
600
800
800
800
1000
1000
1000
Depth (mm)
200
200
200
200
200
200
250
400
400
400
500
500
500
800
800
800
(1) Integrated into a floor-mounted control box
(2) On a base plate h=200 mm, i.e. control box of height 1600 + 200
TSI
PRESENTATION
Both innovative and original in design, the TSI is perfectly suited to applications where the transfer of a main source to a replacement source is crucial for the
running of your installations.
Straightforward and easy to use, the special feature of this module is that it is automatically configured when voltage is provided from the grid side.
By simply pressing the AUTO key, the following parameters are configured: grid voltage, voltage min/max thresholds, type of use, frequency min/max
thresholds.
Electronic switching of the power source means that the unit can be continuously self-supplied.
14
Screen
with integrated backlighting, with
2 lines of 16 characters
Confirm key
Rotophase LED
Shows the direction
of rotation
of the phases
AIPR
Above 630A, power modules called AIPR are separated from the control/
command.
These control boxes are fitted on the generating set chassis and connected
to the alternator.
AIPR 1
AIPR 2
•
O
•
O
O
O
O
O
Voltage 208V-440V
Power connection bus bars
Protection index
•
•
IP 207
•
•
IP 207
height (mm)
width (mm)
depth (mm)
1020
560
238
1260
665
360
With manual control on the front panel
Compact 3 pole circuit breaker
Compact 4 pole circuit breaker
Motorised control option**
With 3 pole circuit breaker, open type
With 4 pole circuit breaker, open type
Other specifications
Dimensions
** The motorised control includes: a closing electromagnet, a shunt trip coil and an AC engine
• Standard
O Option
Source Status LED
Three-colour LED
showing the status
of the source
Position LED
LED showing the
closed position
of the switch or
changeover switch
15
Navigation
and selection
keys
used for scrolling through
the different electrical value
display screens and for
configuring all the module
parameters to the customer
specifications
Test
used to simulate
generating set starting,
including the possibility of
a changeover sequence
Operating keys
Auto key: automatic configuration
of the module, for automatic operation
in mains power cut or a drop
in voltage
SPECIFICATIONS
Key 1: Forced source 1 operation
Key 2: Forced source 2 operation
Reset key: clears the fault display
TSI MODULE
2 lines on the screen, enabling simultaneous display of the voltage on the grid side and the generating set side. The same applies to the frequency.
6 LEDs provide instantaneous information on the position status of both of the two 2 sources, along with any alarms and faults which arise.
The TSI also offers 3 configurable inputs and 2 outputs, as an option.
ADDITIONAL SPECIFICATIONS
Communication
In addition to a wired connection which enables remote starting via dry contact with all the SDMO control/command modules (Nexys, Telys, Kerys), the
TSI module also has a CAN Bus (as an option from 25A to 200A), allowing it to communicate with the MICS Kerys.
This connection allows all information relating to the grid and the starting order following a variation in voltage to be sent to the Kerys.