User Manual

Add to my manuals
27 Pages

advertisement

User Manual | Manualzz
Menu
HIGH PRESSURE CLEANER
NETTOYEUR HAUTE PRESSION
HOCHDRUCKREINIGER
HIDROLIMPIADORA ALTA PRESIÓN
LAVADORA A ALTA PRESSÃO
ГИДРОМОЙКА ВЫСОКОГО ДАВЛЕНИЯ
IDROPULITRICE AD ALTA PRESSIONE
• OPERATING INSTRUCTIONS
• MODE D’EMPLOI
• BEDIENUNGSANLEITUNG
• INSTRUCCIONES PARA EL USO
• MANUAL DE INSTRUÇÕES
• ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ
• LIBRETTO ISTRUZIONI
• DO NOT USE THE MACHINE WITHOUT FIRST READING THE OPERA TING INSTRUCTIONS
• N’UTILISER L’APPAREIL QU’APRÈS AVOIR LU LE MANUEL D’INSTRUCTIONS
• GERAT ERST NACH LESEN DER BEDIENUNGSANLEITUNG VER WENDEN
• NO UTILISE EL APARATO SIN LEER ANTES LAS INSTRUCCIONES PARA SU USO
• NÃO USE A MÁQUINA SEM LER A MANUAL DE INSTRUÇÕES
• НЕ ИСПОЛЬЗУЙТЕ УСТРОЙСТВО, НЕ ПРОЧИТАВ СНАЧАЛА ИНСТРУКЦИЮ ПО ЭКСПЛУАТАЦИИ
• NON USARE LA MACCHINA SENZA AVERE LETTO LE ISTRUZIONI PER L’USO
INDEX
ENGLISH............................................................................................ pag.
6
FRANÇAIS....................................................................................... pag.
24
DEUTSCH......................................................................................... pag. 42
ESPAÑOL.......................................................................................... pag.
60
PORTUGUÉS................................................................................ pag. 78
РУССКИЙ.......................................................................................... стр..
96
ITALIANO............................................................................................ pag. 114
Models - Modèles - Modelle - Modelos - Модель - Modelli
TSX
TSX
TSX
TSX
TSX
TSX
TSX
TSX
TSX
10.130.2
10.130.4
12.100.2
12.100.4
12.140.2
12.140.3
13.180.2
13.180.3
13.180.4
TSX
TSX
TSX
TSX
TSX
TSX
TSX
TSX
TSX
13.180.5
14.120.2
14.120.3
15.150.2
15.150.3
15.150.4
15.150.5
17.130.2
17.130.3
3
TSX
TSX
TSX
TSX
TSX
TSX
TSX
TSX
17.130.4
17.130.5
951.6
954.6
956.6
957.6
961.6
961.8
TSX series
• CONTROL DEVICES
Before connecting the machine to the water and electrical supplies, it is necessary to know the function of the contr ols
on the machine. This must be done in accor dance with the descriptions in the Instruction Manual, taking
reference to the relevant instructions and illustrations.
• DISPOSITIFS DE CONTRÔLE
Avant de brancher l’appareil sur les réseaux d’alimentation d’eau et d’électricité, il est nécessair e de bien connaître le
fonctionnement de ses dispositifs de contrôle. Ef fectuer cette opération en vous référant aux instructions données
dans ce manuel et aux indications et illustrations y r elatives.
• BEDIENUNGS - UND KONTROLLVORRICHTUNGEN
Bevor Sie das Gerät mit W asser - und Stromanschlüssen verbinden ist es notwending, daß Sie die Bedienungs-und
Kontrollvorrichtungen des Gerätes verstehen. Bitte lesen Sie die Beschr eibungen und Illustrationen der
Bedienungsanleitung.
• DISPOSITIVOS DE PUESTA EN MARCHA Y CONTROL
Antes de conectar el equipo a las r edes de alimentación de agua y electricidad, es necesario conocer sus dispositivos
de puesta en marcha y control. Efectuar estas operaciones siguiendo las indicaciones que figuran en el manual de
istrucciones así como de sus ilustraciones grafícas corr espondientes.
• DISPOSITIVO DE COMANDO E CONTROLO
Antes da ligação às redes de alimentação hídrica e eléctrica, é necessário saber qual a função dos dispositivos de
comando e controlo da máquina. Efectuar esta operação conforme descrito no Manual de Instruções.
• УСТРОЙСТВА УПРАВЛЕНИЯ
Перед тем, как подсоединить изделие к источникам воды и электроэнергии, необходимо изучить его
устройства управления. Это необходимо сделать в соответствии с описаниями, содержащимися в настоящей
Инструкции по экплуатации, уделяя внимание соответствующим инструкциям и иллюстрациям.
• DISPOSITIVI DI COMANDO E CONTROLLO
Prima dell’allacciamento alla rete di alimentazione idrica ed elettrica è necessario conoscer e la funzione dei dispositivi
di comando e controllo della macchina. Effettuare questa operazione seguendo quanto descritto nel Manuale Istruzioni
facendo riferimento alle indicazioni e illustrazioni r elative.
4
EQUIPEMENT STANDARD
STANDARD EQUIPMENT
Interrupteur Marche/Arrêt
Bouton de régulation de la pr ession
Indicateur de pression
Indicateur de niveau d’huile
Raccord de tuyau haute pression (OUTLET)
Raccord d’alimentation eau et filtre (INLET)
Prise du réservoir extérieur détergent
Molette de dosage du détergent (CHEM)
Bouchon réservoir incorporé
Pistolet automatique
Lance a raccordement rapide “LANCE”
Rototek ou Multireg 99
Tuyau haute pression
Cran de sûreté
ON/OFF switch
Pressure adjusting knob
Pressure indicator
Oil level indicator
High pressure hose connection (OUTLET)
Inlet hose connection with water filter (INLET)
Outer chemical port
Chemical regulator (CHEM)
Built in tank cap
Automatic gun
“LANCE”
Rototek or Multireg 99
High pressure hose
Safety lock
STANDARD AUSRÜSTUNG
EQUIPO STANDARD
EIN/AUS Schalter
Druckregel-Griff
Druckanzeiger
Ölschauglas
Hochdruck-Ausgang (OUTLET)
Wasser-Anschluß mit Filter (INLET)
Externe Chemiesaugdose
Chemiedosierung (CHEM)
Verschluß des eingebauten Chemietanks
Spritzpistole
Wechsel-Lanze “LANCE”
Rototek oder Multireg 99
Hochdruckschlauch
Sicherheitssperre
Interruptor
Mando de regulación de la presión
Mánometro
Mirilla nivel de aceite
Salida presión (OUTLET)
Entrada + Filtro agua (INLET)
Entrada aspiración deposito exter no
Mando de regulación detergente (CHEM)
Tapón deposito interno
Pistola
Lanza
Rototek o Multireg 99
Tubo de alta presión
Seguro
СТАНДАРТНОЕ ОБОРУДОВАНИЕ
EQUIPAMENTO STANDARD
Interruptor lig/des (ON/OFF)
Manipulo de ajuste de pressão
Indicador de pressão
Indicador de nivel de óleo
Conector de saida de alta pr essão (OUTLET)
Entrada de agua com filtro (INLET)
Entrada de aspiração de detergente
Regulador de detergente (CHEM)
Tampa do depósito inter no
Pistóla automática
Lança
Bico (ROTOTEK ou MULTIREG 99)
Lanço de tubo de alta pr essão
Travão
Выключатель
Регулятор давления
Манометр
Индикатор уровня масла
Выход (OUTLET)
Вход + Водяной фильтр
Вход всасывающего патрубка наружного бака
Регулировка моющего средства (CHEM)
Пробка внутреннего бака
Пистолет
Гидромонитор
Rototek или Multireg 99
Шланг высокого давления
Предохранитель
EQUIPAGGIAMENTO STANDARD
Interruttore
Comando di regolazione della pressione
Manometro
Spia livello olio
Uscita (OUTLET)
Entrata + Filtro acqua
Ingresso aspirazione serbatoio ester no
Regolazione detersivo (CHEM)
Tappo del serbatoio inter no
Pistola
Lancia
Rototek o Multireg 99
Tubo alta pressione
Sicura
5
ENGLISH
«Translated from the original instructions»
TABLE OF CONTENTS
1 - Description of symbols on the high pr essure cleaner....................................... 7
2 - Technical specifications of the TSX series
high pressure cleaner....................................................................................... 8-9
3 - Product use....................................................................................................... 10
3.1 • Designated use................................................................................... 10
4 - Preliminary operations...................................................................................... 10
4.1 • Unpacking........................................................................................... 10
4.2 • Identification label............................................................................... 11
5 - Installation......................................................................................................... 11
5.1 • Connection high pressure outlet......................................................... 12
5.2 • Connection to water supply................................................................ 12
5.3 • Connection to electric system............................................................ 13
5.3.1 • Cut-out switch (Only the United States).......................................... 14
5.4 • Use of extention cor d......................................................................... 14
5.5 • Start-up............................................................................................... 15
6 - General warnings.............................................................................................. 16
7 - Chemical product use...................................................................................... 19
7.1 • Suction from internal tank ................................................................. 19
7.2 • Suction from external tank ................................................................ 19
8 - Use of "ROTOTEK" or "MULTIREG 99"........................................................... 20
9 - Precautions againt freezing, and instructions for storage................................. .. 20
10 - Maintenance...................................................................................................... 20
10.1 • Oil change......................................................................................... 21
10.2 • Inlet filter............................................................................................ 21
10.3 • Replacement of high pr essure nozzle ............................................. 21
11 - Machine scrapping............................................................................................ 22
12 - Trouble shooting............................................................................................... 23
6
1 - DESCRIPTION OF SYMBOLS ON THE HIGH PRESSURE CLEANER
Read the instruction
manual before use.
Garanted sound
power level.
Do not direct the jet
against persons or
animals power outlets or the machine
itself.
Special waste. Do
not dispose of this
product in normal
household garbage
Warning! Risk of
electrocution
Warning sign
Grounding
Machine not
prearranged for
connection to the
mains potable
water supply.
7
2 - TSX SERIES HIGH PRESSURE CLEANERS TECHNICAL SPECIFICA TIONS
TSX
TSX
10.130.2
10.130.4
MODEL
TSX
12.100.2
12.100.4
TSX
12.140.2
12.140.3
14.120.2
14.120.3
TSX
13.180.2
13.180.3
13.180.4
13.180.5
TSX
15.150.2
15.150.3
15.150.4
15.150.5
SINGLE PHASE SINGLE PHASE TRIPLE PHASE TRIPLE PHASE TRIPLE PHASE TRIPLE PHASE
Flow rate
Equivalent
washing impact
with rotating
nozzle jet
l/min.
9,5
12
12
14
13
15
G.P.M.
USA
2.5
3.2
3.2
3.7
3.4
4
E.W. bar / MPa / P.S.I.: specific jet pressure in bar / MPa / P.S.I.
23
230
3200
13
130
17
170
2450
10
100
24,5
245
3450
14
140
21
210
2950
12
120
31
310
4400
18
180
26
260
3700
15
150
P.S.I.
1885
16
160
2300
1450
13
130
1885
2030
17
170
2450
1740
15
150
2175
2610
21
210
2950
2175
18
180
2610
< 47
< 49
E.W. MPa
E.W. bar
E.W. P.S.I.
MPa
Working pressure
bar
P.S.I.
MPa
Overpressure
peak limit
bar
N
< 29
< 32
< 40
< 41
Absorbed motor
power
kW
3,2
3,2
3,8
3,8
5
5
Cycle
Hz
50
50
50
50
50
50
V
A
230-1~
14,7
240-1~
13,6
230-1~
14,7
240-1~
13,6
230-3~
12,5
400-3~
7,2
230-3~
12,5
400-3~
7,2
230-3~
15,8
400-3~
9,2
240-3~
14,5
415-3~
8,5
230-3~
15,8
400-3~
9,2
240-3~
14,5
415-3~
8,5
2x40µF
2x40µF
–
–
–
–
F
F
F
Recoil thrust of jet
V
A
V
A
Voltage
Amps
V
A
Capacitor
Thermal
Motor protection
Isolating class insulation
Motor protection grade
Noise level
*
Lance vibration
*
m/sec2
Max. water inlet
temp
°C
°F
F
F
IPX5
Lp dB(A) 80 (uncertainly 1,5) - Lw dB(A) 94
Fixed nozzle A(8) than 2,5 -Rotating nozzle A(8) 7 (uncertainly 1)
60
140
MPa 1 - bar 10 - P.S.I. 145
Max inlet pressure
m
Max suction depth
High pressure hose
Mass
Dimensions
*
F
ft
3
9,8
8m
26 ft
3
9,8
3
9,8
3
9,8
1
3,3
Steel reinforced rubber - Inter nal diameter 5/16"
Working pressure max 200 bar - 20 MPa - 2900 P .S.I.
Kg 44,5 - Ibs 98
Kg 54 - Ibs 119
860x400x875 (h)
33,8x15,7x34,4 (h)
dry
(max.)
mm
inches
(Reference Standard EN60335-2-79).
8
1
3,3
2 - TSX SERIES HIGH PRESSURE CLEANERS TECHNICAL SPECIFICA TIONS
TSX
TSX
TSX
l/min.
17
11,5
13,6
G.P.M.
USA
4.5
3
3.6
TSX
TSX
TSX
TSX
13
13
15,9
15
3.4
3.4
4.2
4
955.6
961.6
957.6
956.6
17.130.2
951.6
954.6
961.8
17.130.3
17.130.4
17.130.5
TRIPLE PHASE SINGLE PHASE SINGLE PHASE TRIPLE PHASE TRIPLE PHASE SINGLE PHASE TRIPLE PHASE
MODEL
Flow rate
E.W. bar / MPa / P.S.I.: specific jet pressure in bar / MPa / P.S.I.
Equivalent
washing impact
with rotating
nozzle jet
17
170
2450
10,3
103
16
160
2300
9
90
18,7
187
2700
11
110
250
3550
14,5
145
P.S.I.
1885
16
160
2300
1500
13,3
133
1929
1300
12
120
1740
1600
14
140
2030
2100
17,5
175
2538
14,5
145
2100
7,6
76
1100
10,6
106
1537
N
< 51
< 31
< 35
< 37
< 41
< 37
E.W. bar
E.W. P.S.I.
MPa
Working pressure
bar
P.S.I.
MPa
Overpressure
peak limit
25
23
230
3200
13
130
E.W. MPa
bar
Recoil thrust of jet
26
260
3700
15
150
2175
18
180
2610
< 49
Absorbed motor
power
kW
5
3,2
3,2
3,4
4,6
3,2
5
Cycle
Hz
50
60
60
60
60
60
60
V
A
230-3~
15,8
400-3~
9,2
240-3~
14,5
415-3~
8,5
220-1~
15,5
220-1~
15,5
200-3~
12,0
220-3~
16,5
220-1~
15,5
220-3~
15,8
380-3~
9,2
–
2x40µF
2x40µF
–
–
2x40µF
–
F
B
F
V
A
V
A
Voltage
Amps
V
A
Capacitor
Thermal
Motor protection
F
Lance vibration
Fixed nozzle A(8) than 2,5 -Rotating nozzle A(8) 7 (uncertainly 1)
60
140
*
*
m/sec2
Max. water inlet
temp
°C
°F
B
IPX5
Lp dB(A) 80 (uncertainly 1,5) - Lw dB(A) 94
MPa 1 - bar 10 - P.S.I. 145
Max inlet pressure
m
Max suction depth
High pressure hose
Mass
Dimensions
*
B
F
Isolating class insulation
Motor protection grade
Noise level
ft
1
3,3
8m
26 ft
1
3,3
1
3,3
1
3,3
3
9,8
1
3,3
Steel reinforced rubber - Inter nal diameter 5/16"
Working pressure max 200 bar - 20 MPa - 2900 P .S.I.
Kg 44,5 - Ibs 98
Kg 54 - Ibs 119
860x400x875 (h)
33,8x15,7x34,4 (h)
dry
(max.)
mm
inches
(Reference Standard EN60335-2-79).
9
1
3,3
WE CONGRATULATE YOU on your choice that shows your level of technical knowledge and
love of beautiful objects.
In fact, you have pur chased a highly technological machine pr oduced by the world's
largest manufacturer of high pressure cleaner pumps.
This machine is so useful and versatile that you will use it for many years.
THIS BOOKLET IS AN INTEGRAL P ART OF YOUR MACHINE AND SHOULD BE
CAREFULLY READ BEFORE PROCEEDING WITH INST ALLATION, ST ART-UP AND
USE.
This booklet contains important safety information and instructions for use and maintenance
of the high pressure cleaners series TSX and should be kept in a safe place.
3. PRODUCT USE
3.1 DESIGNATED USE
The machine is exclusively designed for washing, by way of a pr essurized water jet, objects,
things or any surface suitable for cleaning by a pr essurized water jet with the possibility of
adding liquid detergent.
ATTENTION: this appliance was designed for use of deter gents recommended by the manufacturer. The use of other chemical pr oducts may jeopardize the safety of the appliance itself.
The liquid deter gent additives must be chosen in consideration of the chemical compatibility
with the components of the pump and of the surface to be cleaned.
IMPORTANT: use only detergents that are biodegradable, and in any case complying with the
regulations applicable in the country wher e they are used.
THE DESIGNATED USE OF THIS PRODUCT MUST BE RESPECTED. ANY OTHER USE
OF THIS PRODUCT IS CONSIDERED INCORRECT.
THE MANUFACTURER IS NOT RESPONSABLE FOR DAMAGE CAUSED TO THE
MACHINE WHEN USED INCORRECTLY.
THE MACHINE MUST NOT BE TAMPERED WITH FOR ANY REASON. IN SUCH CASES
THE MANUFACTURER IS NOT RESPONSIBLE FOR THE MALFUNCTIONING
OR SAFETY OF THE MACHINE.
IT IS FORBIDDEN TO STORE OR USE THE UNIT IN ENVIRONMENTS WITH
POTENTIALLY EXPLOSIVE ATMOSPHERE
4. PRELIMINARY OPERATIONS
4.1 UNPACKING
Unpack and make sure that the machine is complete and undamaged.
If the machine appears damaged in any way , do not use the machine and consult our dealer .
For shipping reasons some parts may be included separately . In this case assemble parts as
indicated in this booklet.
Keep all packaging materials (bags, boxes, tape) out of r each of children.
10
TSX
4.2 - IDENTIFICATION LABEL
Before using the machine, make sure that it is provided with the
identification Label. In case the Identification Label is missing,
do not use the machine and consult your dealer immediately .
The Identification Label with the technical specifications is fixed
to the motor.
Check that the mains voltage is the same as shown on the identification label.
5 - INSTALLATION
C
Body of the unit
Handle
Kit of screws + washers + nuts
Hose hanger
Fan grid
Cover fixing knob
Replace the red plug (Fig. 1) with the black and yellow
dipstick (Fig. 2) and check that the oil in the sigth
glass is at half-way level (Fig. 3).
D
A
D
Remove the cap of the chemical tank
Unscrew cover fixing knob
Remove the cover
Insert fan grid into its holes and push firmly until it is
fully locked.
E
B
1
2
3
B
E
Insert the handle in its guides.
Fix the handle and hose hanger by using scr ews,
nuts and washers supplied.
Fix the bottom of the handle by using scr ews, nuts
and washers supplied.
11
Replace the cover.
Reinsert the chemical tank cap.
Lock cover fixing knob.
5.1 HIGH PRESSURE CONNECTION
1 - Connect one end of the high pr essure hose to the automatic gun (A) and the other end to
the OUTLET connection on the machine. Tighten firmly (B).
2 - Complete the assembly by coupling the extension to the gun/lance and tighten firmly (C).
5.2 - CONNECTION TO THE W ATER SUPPLY
1- The maximum temperature of the inlet water must not exceed 60°C (140°F).
2. WARNING: You can connect the machine INLET (D) fitting to the mains water supply
only by installing:
• an approved check valve in compliance with IEC EN 61770 on the mains water supply outlet.
• and using a hose with inside diameter of at least 13 mm. (1/2”) in compliance with IEC
EN 61770.
3- Since the water flow decreases according to the length of the hose, make sure that the quantity of water supplied to the machine is not less than the quantities indicated in the chart below.
4- The pressure of the inlet water must not exceed 10 bar , 1 MPa, 145 psi.
ATTENTION: The water supply which enters into the washer is not drinkable.
TSX SERIES
MODEL
TSX 10-130
TSX 12-100
TSX 12-140
TSX 951
TSX 14-120
TSX 13-180
TSX 954
TSX 955
TSX 956
TSX 15-150
TSX 17-130
TSX 957
TSX 961
FLOW RATE OF
WATER SUPPLY
L/min.
G.P.M. USA
15
4
17
4.5
20
5.3
If the user wishes to power the washer by means of free suction, simply emerge the end of the
supply tube in the water to be suctioned. The maximum suction depth consider ed as the distance in height between the water surface and the pump varies between 1 m. and 3 m. (see
technical specifications table).
IMPORTANT
The water supplied to the machine must be clean. Running the unit without water, or with water
which is dirty, contains grit or corrosive liquids, causes serious damage to the machine.
12
5.3 - CONNECTION TO ELECTRICAL SYSTEM
1 - Check that the voltage of the electrical system (mains) is the same as indicated on the ID
label of the machine.
2 - Check that the plug complies with local safety r
egulations, and that it is pr ovided with
ground connection (earth).
3 - Ensure that the outlet is pr otected by a "cut-out" (differential magnetic-thermal switch with
sensitivity of less than 30mA per 30ms) or that a device is pr esent which can test the earthing
circuit.
4 - Do not connect other appliances contemporaneously to the same power outlet.
5 - Insert the plug only after checking that the machine switch is in the OFF position.
The TSX cleaners series are supplied without electric plug.
The assembly of the electrical plug must be done in conformity with IEC rule n. 60364-1 and
must be effected by qualified personnel, respecting following prescriptions:
1- Use a plug which complies with the local safety r egulations and which must necessarily be
grounded.
2- Make sure that the cord/plug connection is perfectly sealed and water -tight.
3- Use plugs that conform to the indications on the ID T ag.
4- Unroll the cord completely to avoid overheating.
5- Do not crush on the power cor d.
6- Do not use the high pr essure cleaner if the electric cable is damaged.
7- If the power cord is damaged, its replacement can be effected only by the technical service
personnel or by a qualified technician.
In case of dir ect connection without plug, the connection to the electric network must be in
compliance with the standard IEC 60364-1 and must be made by a qualified installer . If a plug
connector is used as a sectioning device, this must be in an easily accessible position.
In the threephase models the three power leads of the power cord can be connected to any of
the three phases from the power network. The fourth, green-yellow lead must be connected to
the ground pin.
The washer must only be connected to a power mains with a maximum network impedance of
Zmax=0.3 Ω.
WARNING: IN CASE OF POWER F AILURE DURING USE OF THIS MACHINE, TURN
THE MACHINE POWER SWITCH TO THE OFF POSITION FOR SAFETY REASONS.
13
5.3.1 - CUT-OUT SWITCH (Only the United States)
This UL version high-pressure washer is equipped with a cut-out switch contained in the power
cable plug.
Said equipment provides extra protection against the risk of electric shock.
When replacing the plug or cable, use the same components including the cut-out device.
5.4 - USE OF CORDS
If an extension cor d is used, make sur e that plug and r eceptacle are of a water -tight type. In
any case they must be raised fr om the ground in order to avoid possible contact with water.
Use only extension cables with the same number of conductors as those of the machine cable,
including the earthing cable, and with a suitable plug/socket for the cable used.
Only use extension cor ds for outdoor use. Said type of cable is marked "Suitable for outdoor
use." Store inside when not in use.
Do not use damaged extension cor ds. Cables should not be located near sour ces of heat or
sharp edges. Always disconnect the plug from the socket before removing the extension cord
from the product. Do not pull the cable to pull the plug out of the outlet. Do not touch the plug
or connections with wet hands.
SELECTION TABLE
WARNING
USE OF INADEQUATE
Voltage
EXTENSION CORDS
Extension
cord length
Cord section
mm2
MAY CAUSE SAFETY
230÷240
Up to 20 m
2,5
HAZARDS
230÷240
From 20 to 50 m
4
400÷415
Up to 50 m
2,5
14
5.5 - START-UP
- Before starting up and using the machine, make sur e that it is positioned on the gr ound or
leaning against a stable support and that the r esting surface is level or with a minimum slope.
- It is ESSENTIAL to ensur e that the suction filter is clean befor e use. (see maintenance chapter – 10.2 suction).
1- Open water supply
2- Push ON button
3 - Open the gun with nozzle end up and keep in open position to allow air to escape fr om the
hose.
4 - Regulate water pressure by rotating the regulator knob.
ATTENTION: in the cleaners high pr essure with “TOTAL STOP” device, the motor
stops approximately 20 seconds after the gun is closed.
You are ready to work!!!
5 - At the end of working session tur n the machine switch to the OFF position.
6 - Open the gun to r elease remaining pressure from the hose.
15
6 - GENERAL WARNINGS
High pressure cleaners can be used neither
by childr en nor by non authorized persons.
Children must be supervised to pr event them
from playing with the machine.
Keep this machine out of r each of childr en
at all times.
This equipment was not designed to be used
by persons with reduced physical, sensorial or
mental capabilities, or with limited experience
or knowledge, unless a person r esponsible for
their safety pr ovides them with supervision or
the instructions for the use of the equipment.
NO
The high pressure water jet may be dangerous if used incorrectly. Never direct the jet at persons and/or animals, electrical appliances or the machine itself. Do not use the machine when
persons and/or animal are within the range of its high pr essure jet.
Do not direct the jet against yourself or other persons to clean clothes or shoes.
Only operate the machine in safety conditions, avoiding any potentially danger
ous
situation for the user and others. The machine
operator should:
• Avoid to operate the machine on unbalanced
surfaces;
• Remember that the high pr essure water jet
causes a r ecoil effect on the pistol. The r ecoil
values are indicated in the technical specifications table;
• Use protective clothing.
NO
• W ear pr otective goggles and rubber slipproof boots
• Avoid dispersing substances that ar e polluting, toxic or harmful in any way.
ATTENTION: Risk of explosion. Do not spray
flammable liquids.
NO
16
This machine has been built in conformity
with current safety regulations. Use of electric
appliances requires the observations of a few
simple rules:
Do not touch electric parts when the machine
is on.
Inspection, maintenance and repairs should be
carried out by qualified personnel. In any case
unplug the machine befor e performing any of
the above operations.
NO
Do not pull the cord to disconnect the power
supply and do not pull on the hose to move the
machine.
ATTENTION: high pr essure flexible hoses,
high pr essure connectors, safety devices,
electrical connections and spray guns ar
e
important for the safety of the device.
NO
Do not start the unit if the power cor
d is
damaged. Apply to qualified personnel for its
replacement. Replacement cor ds should have
the same technical specifications as the original cord. Do not carry out repairs on the electrical cord and avoid cord damage.
NO
Do not start the unit if the high pr essure hose, connectors and the gun ar e damaged. By
replacement make sure that the new components have at least the same rating as the original
components.The technical specifications of the hose should be printed on the hose itself (max
pressure, production date, manufacturer).
17
Avoid covering the machine during use and
use the machine in a well ventilated ar ea.
NO
Do not leave the machine running for mor e
than 5 minutes with the pistol closed. After
this time period the water temperatur e within
the machine increase and may cause damage
to the machine.
5 min.
NO
When the machine is of f insert the safety
device on the gun to avoid accidental opening.
The
unit is equipped with a current-thermal overload pr otector which switches and electrically
disconnects the motor in case of overheating.
If this should happen, please r efer to the "T rouble
Shooting" section in this manual.
To ensure the security of the machine, use only original spare parts and accessories supplied
by the manufacturer.
THE MANUFACTURER CANNOT BE HELD RESPONSABLE FOR ANY DAMAGE CAUSED BY DISRESPECTING THE DESIGNA
TED USES OF THIS
MACHINE, IT'S INSTRUCTIONS AND W
ARNINGS INDICA TED IN THIS
BOOKLET.
18
7 - HOW TO USE CHEMICAL PRODUCTS
The TSX series high pr essure cleaners have been constructed to permit the suction and mixing of detergents and other liquids from the internal tank.
In the event of direct contact with detergent additives, follow instructions provided by the manufacturer and/or product retailer and rinse the af fected body part with clean water.
7.1 - SUCTION FROM INTERNAL TANK
Fill the tank, as shown in Fig. 1. Select the low pr
essure by operating the Rototek or
Multireg 99 (Fig. 2).
Make sure that the outer chemical ports is plugged (Fig. 3).
Adjust the chemical quantity by using the suitable cursor +/- (Fig. 3).
In order to empty the tank, open the plug located at the bottom of the machine (Fig. 4).
Capacity of the built-in tank: 7,5 litr es.
1
2
3
4
7.2 - SUCTION FROM EXTERNAL TANK
Remove the plug fr om the chemical port (Fig. 1). Fit che connector of kit “A” into the chemical port (CHEM) and plunge the filter into the separate tank “B” (Fig. 2).
Select the low pr essure by operating the Rototek or Multir eg 99 (Fig. 3). Adjust the chemical
quantity by using the cursor +/- (Fig. 4). When you have finished working, r emove kit “A” from
the chemical port and reinsert the plug (Fig. 5).
1
2
3
5
19
4
8 - USE OF ROTOTEK OR MULTIREG 99
Pressure selection must be carried out with closed pistol (1)
A - selection of the pr essure
• High pressure (2)
• Low pressure (3)
A
B - selection of the jet
• straight pin jet (4)
• fan jet (5)
2
1
L
H
B
4
L
H
3
L
H
5
L
H
F
OF
9 - PRECAUTIONS AGAINST FREEZING AND INSTRUCTIONS FOR STORAGE
If the machine is stored where temperatures fall below the freezing level, it is advisable to suck
antifreeze (similar to that used for automobiles) into the pump before storage. In any case keep
the machine in a warm r oom for a couple of minutes befor e use.
10 - MAINTENANCE
• Maintenance and repairs should always be performed by trained and authorised personnel.
• Before carrying out any cleaning, maintenance and/or parts r eplacement, disconnect the
machine from the power mains, removing the plug from the power outlet.
• Proper maintenance favours a longer duration of operation and impr oved performance.
• Periodically check the conditions of the washer , pressurised parts (pipe, fittings, lance) and
the electrical cable (see "General war nings for use").
Check for any water or oil leaks and/or malfunctions.
If necessary, replace affected parts.
The list of specific machine components and cir cuit diagrams are contained in the booklet
"SPARE PARTS NOMENCLATURE".
Contact Interpump Group customer service in the event of any doubts.
20
10.1 - OIL CHECK AND CHANGE
• The oil level must be checked periodically thr ough the oil sight glass
• Oil must be changed after the first 50 hours of operation of the machine. Subsequent oil
changes must be carried out every 300 hours of machine operation.
• In any case it is advisable to change the oil at least once a year .
• Oil type: SAE 15W40 MINERAL
• Oil capacity. 0,4 liters
• Unscrew the drain plug on the bottom of the pump and the black/yellow dipstick on top.
• Collect the used oil in a tank and convey it to an authorized collection center .
• Replace the drain plug and fill in the oil up the level as shown in the oil level gauge.
• Replace the black/yellow dipstick.
10.2 - INLET FILTER
Before using the machine it is IMPOR TANT to make sur e that the filter is clean. W ash the filter under running water and/or with an air pr essure gun to totally eliminate any deposits in the
filter.
Remember that a clean filter guarantees the good of the machine operation.
Remove the filter from the
water inlet
Clean the filter using an air
pressure gun.
Clean the filter under running water.
10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE
Periodically it is necessary to r eplace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decr ease of the working
pressure. Contact your dealer if you wish to pur chase a new nozzle.
21
11 - DISPOSAL OF THE MACHINE
• In case of no further use of the machine, it is advisable to disconnect the power cor d making the machine inoperative.
• Keep out of reach of children.
• This machine is considered "special waste", disassemble and gather homogeneous parts for
recycling.
• Do not used recycled parts as spare parts.
Information on the disposal of electric and electronic
equipment in compliance with directive 2002/96 CE
(RAEE).
1. Within the European Union
Warning: the product
is marked with this
symbol, which means
that electric and electronic products should
not be disposed of
with the normal
house-hold waste. A
separate collection
system is foreseen for
these products.
Warning: do not use the normal house trash bin to dispose of this
product.
Used electric and electronic equipment must be handled separately
and in compliance with the regulations relating to the treatment,
recovery and recycling of the said products.
In accordance with the regulations applied in the member States, private users resident in the EU can take used electric and electronic
equipment free of charge to designated collection centers*. In some
countries * the local dealer , too, can withdraw the old product free of
charge if the user purchases a new , similar product.
* For more information contact your local campetent authorities.
If you experience difficulties in locating an authorized disposal center,
consult the dealer from whom you purchased the product.
The correct disposal of this product will contribute to ensure that the waste is submitted to the
required treatment, recovery and recycling, preventing the potential negative impact on environment and human health, which could be caused by an unsuitable disposal of the waste.
The national regulations provide sanctions against whoever unlawfully disposes of or abandons
waste of electric or electronic equipment.
2. In countries outside the European Union.
If you wish to dispose of this product, contact your local authorities to get information about the
correct disposal method.
22
12 - TROUBLE SHOOTING
(FOR QUALIFIED PERSONNEL)
TROUBLE
CAUSE
REMEDY
The pump is running but
maximum pressure is
not obtained
Air suction
Worn or dirty valves
Unloader packings worn
Nozzle worn or incorrect
Piston packings worn
Dirty filter
Check suction hose and fittings
Clean or substitute
Check and/or substitute
Check and/or substitute
Check and/or substitute
Check and/or clean
Fluctuating pressure
Damaged, dirty or clogged valves
Air is being sucked
Check, clean and/or substitute
Check suction hose and fittings
Check and/or substitute
Check and/or clean
Worn packings
Dirty filter
Pressure decreases
Excessive noise
Worn nozzle
Dirty or stuck valves
Bypass packings worn
Piston packing worn
Dirty filter
Air suction
Substitute nozzle
Check, clean and/or substitute
Check and/or substitute
Check and/or substitute
Check and/or clean
Check suction hose and fittings
Damaged, dirty or stuck valves
Check, clean and/or substitute
Worn bearings
Water temperature too high
Check and/or substitute
Lower water temperature to
under 60°C
Check and/or clean
Dirty filter
Worn water and oil seals
Seals (water and oil) damaged
Excessively high ambient humidity
Check and/or substitute
Change oil twice as frequently
as advised
Water leakage from manifold
Piston-packings-worn
O-rings worn
Replace washers
Replace O.R.
Oil leakage
Oil seal worn
Replace oil seal
The motor hums but does not run
when turned on
System voltage is lower to the
minimum advised
The pump is stuck or fr ozen
Extension cord incorrect
Check that your power source
is adequate
See page 20
Consult the extension cord
table on page 14
The motor does not start when
switched on
The plug is not well connected
No power supply
Check plug, cord and switch
The motor stops
The thermal protector has turned
the machine off for overheating
Check that the voltage is corr ect.
Turn off and let cool down
for a few minutes
before turning on again
23
EC DECLARATION OF CONFORMITY (In accordance with Annex II of European Directive 2006/42/CE)
The manufacturer INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italy
DECLARES under sole responsibility that the machine identified and described as follows:
Machine type: Portable high pressure washer (EEE category: household appliance)
Trademark: INTERPUMP GROUP
Model: TSX
complies with the requirements of the directives listed below and subsequent updates:
- Machinery Directive 2006/42/CE
- Low Voltage Directive 2006/95/EC
- Electromagnetic compatibility Directive 2004/108/EC
- Directive 2011/65/EU - RoHS on the restriction of the use of certain hazardous substances in electrical and electronic equipment
The equipment does not contain more than the specified concentrations of restricted substances listed in Annex II except for the applications
exempted from the restriction listed in Annex III.
- Waste electrical and electronic equipment directive 2012/19/EU
- Directive 2000/14/EC on noise emission in the environment
Conformity evaluation pursuant to Annex V
Sound power: Lw= 93 dB(A) - Guaranteed sound power: Lw= 94 dB(A)
The manufacturer, through company measures, guarantees that all machinery manufactured conform to what has been declared.
Standards applied:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Person authorised to compile the technical file
Name: Maurizio Novelli
Address: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italy
Person authorized to draw up the declaration:
CEO Mr. Paolo Marinsek
Reggio Emilia May/2014
Signature___________________________________
DÉCLARATION DE CONFORMITÉ CE (Conformément à l'annexe II de la Directive Européenne 2006/42/CE)
Le fabricant INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italie
DÉCLARE sous sa seule responsabilité que la machine identifiée et décrite comme suit :
Type de machine: Nettoyeur mobile à haute pression - (catégorie d'appareils AEE)
Marque de fabrique: INTERPUMP GROUP
Modèle: TSX
Est conforme aux spécifications des directives énumérées ci-dessous et mises à jour suivantes :
- Directive Machines 2006/42/CE
- Directive de basse tension 2006/95/CE
- Directive de compatibilité électromagnétique 2004/108/CE
- Directive relative à la limitation de l'utilisation de certaines substances dangereuses dans les équipements électriques et électroniques
2011/65/UE - RoHS
L'équipement ne contient pas de substances assorties de restrictions concernant l'utilisation en concentration plus élevée que celles
énumérées à l'annexe II, sauf pour des applications exemptées des restrictions énumérées à l'annexe III.
- Directive sur les rebuts d'appareillages électriques et électroniques 2012/19/UE
- Directive 2000/14/CE sur le bruit ambiant
Évaluation de la conformité à l'annexe V
Puissance sonore : Lw= 93 dB(A) - Puissance sonore garantie : Lw= 94 dB(A)
Le fabricant, par des accords d'entreprise, veille à ce que toutes les machines produites soient conformes à ce qui est déclaré.
Normes appliquées: • EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Personne autorisée à réaliser le manuel technique
Nom : Maurizio Novelli
Adresse: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italie
Personne autorisée à rédiger la déclaration :
L'administrateur délégué Ing. Paolo Marinsek
Reggio Emilia Mai/2014
Signature ___________________________________
132
KONFORMITÄTSERKLÄRUNG (gemäß Anhang II der Europäischen Richtlinie 2006/42/EG)
Der Hersteller INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italien
ERKLÄRT auf alleinige Verantwortung, dass die wie folgt bezeichnete und beschriebene Maschine:
Maschinentyp: Tragbarer Hochdruckreiniger (elektronische und elektromechanische Haushaltsgeräte)
Herstellermarke: INTERPUMP GROUP
Modell: TSX
mit den nachstehend aufgelisteten Richtlinien und ihren nachfolgenden Aktualisierungen konform ist:
- Maschinenrichtlinie 2006/42/EG
- Niederspannungsrichtlinie 2006/95/EG
- Richtlinie 2004/108/EG über die elektromagnetische Verträglichkeit
- Richtlinie zur Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und Elektronikgeräten 2011/65/EU - RoHS
Das Gerät enthält keine Stoffe, für die Beschränkungen bezüglich ihrer Verwendung in Konzentrationen bestehen, die über denen im
Anhang II liegen, mit Ausnahme von Anwendungen, die von den im Anhang II aufgeführten Beschränkungen ausgenommen sind.
- Richtlinie 2012/19/EU über Elektro- und Elektronikaltgeräte
- Richtlinie 2000/14/EG über umweltbelastende Geräuschemissionen
Bewertung der Konformität nach Anhang V
Schallleistung: Lw= 93 dB(A) - Garantierte Schallleistung: Lw= 94 dB(A)
Der Hersteller garantiert mittels unternehmensinterner Maßnahmen, dass alle produzierten Maschinen mit der vorliegenden Erklärung
konform sind.
Angewandte Normen:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Person, die bevollmächtigt ist, die relevanten technischen
Unterlagen zusammenzustellen:
Maurizio Novelli
Adresse: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italien
Person, die zur Ausstellung dieser Erklärung bevollmächtigt ist:
Der Geschäftsführer Ing. Paolo Marinsek
Reggio Emilia Mai 2014
Unterschrift ___________________________________
DECLARACIÓN DE CONFORMIDAD (De acuerdo con el anexo II de la Directiva Europea 2006/42/CE)
El fabricante INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italia
DECLARA bajo su propia y exclusiva responsabilidad a la máquina identificada y descrita del siguiente modo:
Tipo de máquina: hidro-limpiadora móvil de alta presión (categoría AEE electrodoméstico)
Marca del fabricante: INTERPUMP GROUP
Modelo: TSX
Resulta ser conforme con las directivas que se indican a continuación y con sus sucesivas actualizaciones:
- Directiva de Máquinas 2006/42/CE
- Directiva sobre la baja tensión 2006/95/CE
- Directiva sobre la compatibilidad electromagnética 2004/108/CE
- Directiva acerca de la restricción del uso de determinadas sustancias peligrosas en máquinas eléctricas y electrónicas 2011/65/UE - RoHS
La máquina no contiene sustancias con restricción de uso en concentración mayor de aquellas citadas en el anexo II, exceptuando las
aplicaciones exentes de las restricciones citadas en el anexo III.
- Directiva sobre los residuos de aparatos eléctricos y electrónicos 2012/19/UE
- Directiva sobre emisiones acústicas ambientales 2000/14/CE
Valoración de la conformidad contenida en el anexo V
Potencia sonora: Lw= 93 dB(A) - Potencia sonora garantizada: Lw= 94 dB(A)
El fabricante, a través de medidas tomadas por la empresa, garantiza que todas las máquinas fabricadas cumplen con todo lo declarado
con anterioridad.
Normas aplicadas:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Persona autorizada a realizar el fascículo técnico
nombre: Maurizio Novelli
Dirección: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italia
Persona autorizada a redactar la declaración:
El administrador delegado Ing. Paolo Marinsek
Reggio Emilia Mayo de 2014
Firma _______________________________________
133
DECLARAÇÃO CE DE CONFORMIDADE (Nos termos do anexo II da Directiva Europeia 2006/42/CE)
O fabricante INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Itália
DECLARA sob a sua exclusiva responsabilidade que a máquina identificada e descrita tal como se segue:
Tipo de máquina: Máquina móvel de limpeza por jacto de água a alta pressão (categoria AEE electrodoméstico)
Marca de fábrica: INTERPUMP GROUP
Modelo: TSX
Está em conformidade com as directivas abaixo indicadas e posteriores actualizações:
- Directiva Máquinas 2006/42/CE
- Directiva sobre a baixa tensão 2006/95/CE
- Directiva sobre a compatibilidade electromagnética 2004/108/CE
- Directiva sobre a restrição de uso de determinadas substâncias perigosas em aparelhos eléctricos e electrónicos 2011/65/UE - RoHS
O equipamento não contém substâncias com restrições de uso em concentração superior às indicadas no anexo II, à excepção das
aplicações isentas pelas restrições indicadas no anexo III.
- Diretriz relativa aos resíduos de equipamentos eléctricos e eletrônicos 2012/19/UE
- Directiva sobre as emissões acústicas ambientais 2000/14/CE
Avaliação da conformidade, de acordo com o anexo V
Potência acústica: Lw= 93 dB(A) - Potência acústica garantida: Lw= 94 dB(A)
O fabricante, mediante disposições da empresa, garante que todas as máquinas produzidas estão em conformidade com as declaraçõe.
Normas aplicadas:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Pessoa autorizada a compilar a documentação técnica
Nome: Maurizio Novelli
Morada: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Itália
Pessoa autorizada a redigir a declaração:
O administrador delegado Eng.º Paolo Marinsek
Reggio Emilia Mayo de 2014
Assinatura ___________________________________
ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ (В соответствии с Приложением II к Европейской директиве 2006/42/EC)
Изготовитель INTERPUMP GROUP S.p.A. – Via E. Fermi, 25 – 42049 S. ILARIO D’ENZA (RE) – Италия,
ЗАЯВЛЯЕТ под собственную ответственность, что машина:
Тип машины: Моечная машина высокого давления (бытовой прибор категории AEE)
Торговая марка: INTERPUMP GROUP
Модель: TSX
соответствует перечисленным ниже директивам и последующим обновлениям:
- Директива о машинах 2006/42/EC
- Директива о низком напряжении 2006/95/EC
- Директива по электромагнитной совместимости 2004/108/EC
- Директива об ограничении использования некоторых опасных веществ в электрическом и электронном оборудовании
2011/65/UE - RoHS
Оборудование не содержит запрещенных веществ с ограничениями для использования в концентрациях, превышающих
перечисленные в Приложении II, за исключением применений, на которые не распространяются ограничения, перечисленные
в Приложении III.
- Директива об утилизации электрического и электронного оборудования 2012/19/ЕС
- Директива 2000/14/ЕС о шумовом излучении в окружающую среду
Оценка соответствия согласно приложению V
Уровень шума: Lw= 93 dB(A) – Гарантируемый уровень шума: Lw= 94 dB(A)
На основании принятых предприятием мер производитель гарантирует, что все машины, соответствуют заявленному.
Примененные стандарты:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Лицо, уполномоченное составлять техническую документаци
имя: Маурицио Новелли
Адрес: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 – 42049 S. ILARIO D’ENZA (RE) – Италия,
Лицо, уполномоченное составлять декларацию:
Генеральный директор инж. Паоло Маринсек
Реджио-Эмилия. -Май 2014 г
Подпись ___________________________________
134
DICHIARAZIONE CE DI CONFORMITA' (Ai sensi dell'allegato II della Direttiva Europea 2006/42/CE)
Il produttore INTERPUMP GROUP S.p.A. - Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italia
DICHIARA sotto la propria esclusiva responsabilità che la macchina identificata e descritta come segue:
Tipo di macchina: Idropulitrice mobile ad alta pressione (categoria AEE elettrodomestico)
Marchio di fabbrica: INTERPUMP GROUP
Modello: TSX
Risulta essere conforme alle sotto elencate direttive e successivi aggiornamenti:
- Direttiva Macchine 2006/42/CE
- Direttiva sulla bassa tensione 2006/95/CE
- Direttiva sulla compatibilità elettromagnetica 2004/108/CE
- Direttiva sulla restrizione dell'uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche 2011/65/UE - RoHS
L'attrezzatura non contiene sostanze con restrizioni d'uso in concentrazione maggiore di quelle elencate nell'allegato II ad eccezione delle
applicazioni esentate dalle restrizioni elencate nell'allegato III.
- Direttiva sui rifiuti di apparecchiature elettriche ed elettroniche 20102/19/UE
- Direttiva sulle emissioni acustiche ambientali 2000/14/CE
Valutazione della conformità di cui all'allegato V
Potenza sonora: Lw= 93 dB(A) - Potenza sonora garantita: Lw= 94 dB(A)
Il fabbricante, mediante accorgimenti aziendali, garantisce che tutte le macchine prodotte siano conformi a quanto dichiarato.
Norme applicate:
• EN 60335-1 • EN 60335-2-79 • EN 55014-1/2 • EN 61000-3-2/3/11 • EN 62233 • EN 50581
Persona autorizzata a costituire il fascicolo tecnico
nome: Maurizio Novelli
Indirizzo: INTERPUMP GROUP S.p.A.
Via E. Fermi, 25 - 42049 S. ILARIO D'ENZA (RE) - Italia
Persona autorizzata a redigere la dichiarazione:
L'amministratore delegato Ing. Paolo Marinsek
Reggio Emilia Maggio/2014
Firma ______________________________________
135
VIA E. FERMI, 25 - 42049 S. ILARIO - REGGIO EMILIA (ITALY)
TEL. +39 - 0522 - 904311 - TELEFAX + 39 - 0522 - 904444
E-mail: [email protected] - http: //www.interpumpgroup.it
cod. 44.9810.03 - 02/2015 - Rev. 10