TECHNICAL GUIDE - Free Manual Downloads

256819-YTG-J-1208
DESCRIPTION
TECHNICAL GUIDE
SINGLE PIECE VARIABLE SPEED
AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AVY24 THRU 60 AND SVY48 THRU 60
The Affinity Air Handler line offers the ultimate in comfort, sound
and application flexibility. The Affinity models utilize a whisper
quiet variable speed motor that provides humidity control and
the lowest operating cost in the industry. The AVY air handler is
shipped ready to be installed in all positions, upflow, downflow,
horizontal left or right, with minor adjustments. The SVY 48 &
60 models are upflow only models designed into a shorter cabinet, for those special applications where reduced height is
required. No special kits are required to install this deluxe product in any position.
All JCI Unitary Products air handlers and coils use a TXV to provide our customers with the optimum performance and refrigerant control required for 13 + Seer systems. Air handlers can be
ordered with either a R-22 or R-410A TXV factory installed. Air
handlers are also available with “Flex-coils” without a factory
installed metering device, where for added flexibility, a R-22 or
R-410A TXV can be field installed to meet your refrigerant
choice.
FEATURE
ISO 9001
Certified Quality
Management System
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today’s high efficient product. The UPG bolton TXV provides easy installation to convert the air handler to
the required refrigerant, which is a true bolt-on design that does
not require brazing to replace or install.
MicroBlueTM Coated Fins - All air handler coils are treated
with the MicroBlueTM hydrophilic coating to enhance the
removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlueTM coating also reduces the growth of germ causing microbes for a
healthier home environment.
Insulated Cabinet - All air handler cabinets are thermally insulated with 1” foil faced insulation (R-4.2) to prevent sweating.
For applications in extreme humidity conditions an optional,
field installed, external insulating wrap kit is also available.
Factory - Sealed to achieve 2% or less leakage rate with or without field installed filter at 1.0” water gauge external static pressure.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G90 galvanized.
New 4 HK Heat Kit - Installation friendly, easy service, more
robust, unique to new design.
ECM Variable Speed Motor - Designed for efficient, quiet operation with added indoor comfort control. With the use of a humidistat, the motor will monitor the humidity in the home and
automatically keep the desired humidity level in both winter and
summer seasons. The ECM motor utilizes only 24% of the
energy used by standard blower motors to reduce your overall
heating and cooling costs.
ClimaTrak Comfort Settings - Installers can set an operating
cycle for the ECM motor that works best in a particular climate.
Homeowners benefit from an operating cycle that maximizes
their indoor comfort level regardless of whether they live in a
dry, temperate, or humid climate.
Additional rating information can be found at
www.ahridirectory.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
256819-YTG-J-1208
DIMENSIONS
F
10-3/8”
J
K
TOP OUTLET
DIMENSIONS
CIRCUIT
BREAKER
PANEL
18-9/32”
BLOWER
COMPARTMENT
E
A
BOTTOM INLET
DIMENSIONS
DRAIN CONNECTIONS
FOR UPFLOW AND
DOWNFLOW APPLICATIONS
D
REFRIGERANT
CONNECTIONS
7-11/32”
1-1/2”
C
B
FILTER
ACCESS
DRAIN PAN CONNECTIONS
FOR HORIZONTAL APPLICATIONS
DIMENSIONS
Wiring Knockouts1
Dimensions (Inches)
Models
A
B
C
D
Height
Width
E
J
K
Power
Control
F
Depth
Refrigerant
Connections
Line Size
Liquid
Vapor
AVY24B**H21
46
17.5
12-3/8
13-29/32
14-19/32
3/4”
AVY36C**H21
52
21
17-1/8
17-13/32
18-3/32
7/8”
AVY48D**H21
57
24.5
22-1/8
20-29/32
21-19/32
SVY48D**N21
52
24.5
17-1/8
20-29/32
21-19/32
AVY60D**H21
57
24.5
22-1/8
20-29/32
21-19/32
7/8’
SVY60D**N21
52
24.5
17-1/8
20-29/32
21-19/32
7/8”
21.5
(w/o cladding)
22.5
(with cladding)
7/8” (1/2”)
1 3/8” (1”)
7/8” (1/2”)
1 23/32” (1 1/4”)
3/8”
7/8”
7/8”
1. Actual size (Conduit size).
** Thermal expansion device indicators - “2_” indicates R-22 TXV is factory installed, “3X” indicates unit is a “Flex Coil” models with a field installed
R-22 or R-410A TXV, and “4_” indicates R-410A TXV is factory installed. Letter indicates TXV size as required, see outdoor unit technical information for proper matches and requirements.
2
Johnson Controls Unitary Products
256819-YTG-J-1208
COIL TECHNICAL DATA
Models
Application
Refrig.
Conn. Types
Face Area
(Sq. Ft.)
Rows
Deep
Fin
Per In.
Coil Size
Tube
Geometry
Tube
Dia.
Fin
Type
TXV
AVY24B3XH21
None
AVY24B2AH21
AVY24B4EH21
2A
Cooling /
Heat Pump
Sweat
3.89
2
14
(2) 16 x 17.5
1 x 0.866
3/8
Enhanced
4E
AVY24B4FH21
4F
AVY24B4KH21
4K
AVY36C3XH21
None
AVY36C2AH21
2A
AVY36C4EH21
AVY36C4FH21
AVY36C4GH21
4E
Cooling /
Heat Pump
Sweat
4.86
3
12
(2) 20 x 17.5
1 x 0.866
3/8
Enhanced
AVY36C4HH21
4F
4G
4H
AVY36C4KH21
4K
AVY36C4MH21
4M
AVY48D3XH21
None
AVY48D2CH21
2C
AVY48D4FH21
AVY48D4HH21
AVY48D4JH21
4F
Cooling /
Heat Pump
Sweat
5.83
3
11
(2) 24 x 17.5
1 x 0.866
3/8
Enhanced
4H
4J
AVY48D4KH21
4K
SVY48D3XN21
None
SVY48D2CN21
2C
AVY60D3XH21
None
AVY60D2CH2
2C
AVY60D4HH21
AVY60D4JH21
4H
Cooling /
Heat Pump
Sweat
5.83
3
11
(2) 24 x 17.5
1 x 0.866
3/8
Enhanced
4J
AVY60D4KH21
4K
SVY60D3XN21
None
SVY60D2CN21
2C
Note: H models are available with a factory installed horizontal drain pan.
COOLING CAPACITY
Models
Rated CFM
Entering Air °F
(Dry / Wet Bulb)
MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG
35 / 61.5
40 / 68.5
45 / 76.0
50 / 84.0
28.4
25.7
21.0
20.2
41.7
31.8
29.4
23.5
72.0
55.0
40.7
36.81
82.0
62.6
46.2
43.2
24.7
22.3
17.1
12.1
36.8
27.1
21.9
18.3
56.8
42.1
34.0
28.71
62.2
45.8
37.0
33.7
FULL-CASED “A” TYPE MULTI-POSITION
AVY24B**H21
800
AVY36C**H21
1200
AVY48D**H21
SVY48D**N21
1600
AVY60D**H21
SVY60D**N21
1850
Johnson Controls Unitary Products
85/72
80/67
75/62
70/57
85/72
80/67
75/62
70/57
85/72
80/67
75/62
70/57
85/72
80/67
75/62
70/57
35.0
32.2
26.4
21.4
51.3
41.1
32.1
27.6
100.5
80.4
62.7
53.9
119.9
96.0
74.8
64.3
31.8
29.1
23.4
18.6
46.7
36.3
27.0
25.4
86.4
67.5
49.9
47.2
101.0
79.2
58.6
55.4