General-purpose Relays
MK-S New Model
General-purpose Relays Featuring
Mechanical Indicator and Lockable Test
Button
• Built-in operation indicator (mechanical and LED), and new
models with lockable test button.
• Nameplate provided on models with lockable test button.
• RoHS Compliant.
• UL approval for most models. (UL approval pending for models
with built-in LED indicators.)
Features
Two-way Action Test Button
Relay in
Normal Operation
For Momentary
Operation
Yellow
button
Pull down the test
button to the first
position, then press the
yellow button with an
insulated tool to
operate the contact.
For Lock
Operation
Pull down the test
button to the second
position.
(The contact is now in
the locked position.)
Model Number Structure
■ Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
6
7
1. Contact Form
2: DPDT
3: 3PDT
2. Terminals
P: Plug-in
3. Mechanical Indicator/Test Button
Blank: Mechanical indicator
I:
Mechanical indicator and lockable test button
4. LED Indicator
Blank: Standard
N:
LED indicator
5. Coil Polarity
Blank: Standard
1:
Reverse polarity (DC coil only)
6. Surge Absorption
Blank: Standard
D:
Surge absorber diode (DC coil only)
V:
Surge absorber varistor (AC coil only)
7. Internal Connections
Blank: Standard
2 or 5: Non-standard connections (Refer to “Terminal
Arrangement/Internal Connection”.)
8. Rated Voltage
(Refer to “Coil Ratings”.)
General-purpose Relays
MK-S New Model
1
Ordering Information
■ List of Models
Type
Terminals
Standard
Models
Plug-in
Contact form
DPDT
3PDT
Models with
LED Indicator
(See note 2.)
Models with
Diode
(See note 2.)
DPDT
3PDT
DPDT
3PDT
Models with
LED Indicator
and Diode
Models with
Varistor
DPDT
3PDT
DPDT
3PDT
Models with
LED Indicator
and Varistor
DPDT
3PDT
Internal connections
(See note 3.)
With mechanical indicator With mechanical indicator Coil ratings
and lockable test button
Standard
MKS2P
MKS2PI
Non-standard
MKS2P-2
MKS2PI-2
Standard
MKS3P
MKS3PI
Non-Standard
MKS3P-2
MKS3PI-2
MKS3P-5
MKS3PI-5
Standard
MKS2PN(1)
MKS2PIN(1)
Non-standard
MKS2PN(1)-2
MKS2PIN(1)-2
Standard
MKS3PN(1)
MKS3PIN(1)
Non-Standard
MKS3PN(1)-2
MKS3PIN(1)-2
MKS3PN(1)-5
MKS3PIN(1)-5
Standard
MKS2P(1)-D
MKS2PI(1)-D
Non-standard
MKS2P(1)-D-2
MKS2PI(1)-D-2
Standard
MKS3P(1)-D
MKS3PI(1)-D
Non-Standard
MKS3P(1)-D-2
MKS3PI(1)-D-2
MKS3P(1)-D-5
MKS3PI(1)-D-5
Standard
MKS2PN-D
MKS2PIN-D
Non-standard
MKS2PN-D-2
MKS2PIN-D-2
Standard
MKS3PN-D
MKS3PIN-D
Non-Standard
MKS3PN-D-2
MKS3PIN-D-2
MKS3PN-D-5
MKS3PIN-D-5
Standard
MKS2P-V
MKS2PI-V
Non-standard
MKS2P-V-2
MKS2PI-V-2
Standard
MKS3P-V
MKS3PI-V
Non-Standard
MKS3P-V-2
MKS3PI-V-2
MKS3P-V-5
MKS3PI-V-5
Standard
MKS2PN-V
MKS2PIN-V
Non-standard
MKS2PN-V-2
MKS2PIN-V-2
Standard
MKS3PN-V
MKS3PIN-V
Non-Standard
MKS3PN-V-2
MKS3PIN-V-2
MKS3PN-V-5
MKS3PIN-V-5
AC/DC
AC/DC
DC
DC
AC
AC
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.
Example: MKS3P 24 VDC
Rated voltage
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.
Refer to Terminal Arrangement and Internal Connections.
Example: MKS2PIN1-2 24 VDC
Reverse coil polarity
3. Refer to Terminal Arrangement and Internal Connections for non-standard internal connections.
■ List of Models (Order Separately)
Item
Type
Track-mounted Socket 8-pin
11-pin
PF113A-E
8-pin
PF083A-D
11-pin
PF113A-D
Hold-down Clip
(For PF083A-E and PF113A-E)
2
Model
PF083A-E
PFC-A1
General-purpose Relays MK-S
New Model
Specifications
■ Ratings
Coil Ratings
Rated voltage
Rated current
50 Hz
AC
DC
Coil resistance
60 Hz
6V
443 mA
385 mA
3.1 Ω
12 V
221 mA
193 mA
13.7 Ω
24 V
110 mA
96.3 mA
48.4 Ω
100 V
26.6 mA
23.1 mA
760 Ω
110 V
24.2 mA
21.0 mA
932 Ω
200 V
13.3 mA
11.6 mA
3,160 Ω
220 V
12.1 mA
10.5 mA
3,550 Ω
230 V
10.0 mA
11.5 mA
4,250 Ω
240 V
11.0 mA
9.6 mA
4,480 Ω
6V
224 mA
26.7 Ω
12 V
112 mA
107 Ω
24 V
55.8 mA
430 Ω
48 V
28.1 mA
1,710 Ω
100 V
13.5 mA
7,390 Ω
110 V
12.3 mA
8,960 Ω
Must operate
voltage
Must release
voltage
Max. voltage
Power
consumption
80% max. of rated 30% min. of rated 110% of rated voltvoltage
voltage at 60 Hz age
25% min. of rated
voltage at 50 Hz
Approx. 2.3 VA
at 60 Hz
Approx. 2.7 VA
at 50 Hz
15% min. of rated
voltage
Approx. 1.4 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load
Resistive load
(cosφ = 1)
Contact mechanism
Single
Contact material
Rated load
AgSnIn
NO
10 A, 250 VAC
10A, 30 VDC
NC
5 A, 250 VAC
5 A, 30 VDC
Rated carry current
10 A
Max. switching voltage
250 VAC, 250 VDC
Max. switching current
Max. switching power
Inductive load
(cosφ = 0.4)
7 A, 250 VAC
10 A
NO
2,500 VA/300 W
NC
1,250 VA/150 W
General-purpose Relays
MK-S New Model
3
■ Characteristics
Contact resistance
100 mΩ max.
Operate time
AC: 20 ms max.
DC: 30 ms max.
Release time
20 ms max.(40 ms max. for built-in Diode Relays)
Max. operating frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (under rated load)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity
2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite
polarity
Insulation method
Basic insulation
Impulse withstand voltage
4.5 kV between coil and contacts (with 1.2 × 50 µs impulse wave)
3.0 kV between contacts of different polarity (with 1.2 × 50 µs impulse wave)
Pollution degree
3
Rated insulation voltage
250 V
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2 (approx. 100 G)
Malfunction: 100 m/s2 (approx. 10 G)
Endurance
Mechanical: 5,000,000 operations min. (at 18,000 operations/h under rated load)
Electrical: 100,000 operations h. (at 1,800 operations/h under rated load)
Failure rate P level (reference value) 10 mA at 1 VDC
Ambient temperature
Operating: –40 to 60°C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 90 g
Note: 1. The values given above are initial values.
2. P level: λ60 = 0.1 × 10-6/operation
3. Ambient temperature of models with LED indicator is −25 to 60°C.
■ Approved Standards
UL508 (File No. E41515)
Coil ratings
Contact ratings
IEC Standard/TUV Certification:
IEC61810-1 (Certification No.
R50104853)
Operations
6 to 110 VDC N.O.
10 A, 250 V AC 50/60 Hz (Resistive) 6,000
6 to 240 VAC contact 10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
5 A, 250 V AC 50/60 Hz (Resistive)
N.C.
contact 5 A, 30 V DC (Resistive)
Coil ratings
6,000
Contact ratings
6, 12, 24, 48, N.O.
100, 110 VDC contact
6, 12, 24, 100,
110, 200, 220,
N.C.
240 VAC
7 A, 250 V AC 50/60 Hz (General Use)
CSA Standard: CSA Certification by
Operations
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
5 A, 250 V AC 50/60 Hz (Resistive)
100,000
contact 5 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
: CSA C22.2 No. 14
Note: When Relays are mounted on the PF083A-E or PF113A-E, the
maximum carrying current is 9 A.
Note: Applications have been submitted for UL and CSA certification
for models with built-in LED indicators.
Engineering Data
■ Reference Data
100
50
30
DC resistive load
with NO contact
Rated Carry Current vs. Ambient Rated Temperature
Rated carry current (A)
Switching current (A)
Maximum Switching Power
AC resistive load
with NO contact
10
UL derating curve
10
5
AC inductive
load
(cosφ = 0.4)
5
3
AC resistive load
with NC contact
DC resistive
load with
NC contact
1
10
30
50
100
300
500 1.000
0
−40
−20
0
20
40
60
80
Ambient temperature (°C)
Switching voltage (V)
Note: The lower limit of the ambient operating temperature for models with built-in operation
indicators is −25°C.
4
General-purpose Relays MK-S
New Model
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Models without Test Button
Models with Lockable Test Button
34.5 max.
34.5 max.
34.5 max.
0.8
52.5 max.
34.5 max.
0.8
52.5 max.
Sockets
See below for Socket dimensions.
Socket Surface-mounting Socket (for track or screw mounting)
Finger-protection models
Maximum carry current 10 A
--5A
2 poles
PF083A-E
PF083A-D
PF083A
3 poles
PF113A-E
PF113A-E-D
PF113A
Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with "-E" at the end of the model number. When using the PF083A and
PF113A, be sure not to exceed the Socket's maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round
terminals cannot be used for finger-protection models. Use Y-shaped terminals.
PF083A-E (Conforming to EN 50022)
PF113A-E (Conforming to EN 50022)
Terminal Arrangement
Eight, M3.5 × 7 sems
7
Terminal Arrangement
Eleven, M3.5 × 7 sems
4
7
52 max.
4
35.4
52 max.
33
41 max.
3.5
35.4
2
21 max.
Mounting Holes
Two, M4 or two 4.5-dia. holes
4
34
42.8 max.
33±0.2
3.5
2
31 max.
Mounting Holes
Two, M4 or two 4.5-dia. holes
33±0.2
General-purpose Relays
MK-S New Model
5
PF113A-D
PF083A-D
8
Terminal Arrangement
22
5
24
6
5.5
12
4
8
Terminal Arrangement
14
3
32 24 21 22 12
8 7 6 5 4
5.5
27
4
27
4
Eight, M4 screws
7
A2
8
21
1
11
Eight, M4 screws
2
A1
9 10
2 3
34 A2 11 1 A1 14
31 11
Mounting Holes
65
65
Mounting Holes
Two, M4 or two 4.5-dia. hole
Two, M4 or two 4.5-dia. hole
30
30
38
38
Hold-down Clips
PFC-A1
(2 pieces per set)
4.6
60.8
6
62
4.5
Mounting Tracks
PFP-100N, PFP-50N
(Conforming to EN 50022)
PFP-100N2
(Conforming to EN 50022)
16
7.3±0.15
4.5
4.5
35±0.3
15
25
25
10
25
10
1000 (500)*
25 *
35±0.3 27
27±0.15
15
1
25
25
10
Mounting Height with Sockets
Surface-mounting Sockets
77.8
(See
note.)
Three
poles
74.3
PF083A(-E)
87.8
(See
note.)
84.3
PF113A(-E)
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
6
25 15
10
29.2
1
1.5
* A total of twelve 25 × 4.5 elliptic holes is provided with six
holes cut from each track end at a pitch of 10 mm.
* This dimension applies to the PFP-50N Mounting Track.
Two
poles
25
1000±4
24
General-purpose Relays MK-S
New Model
Terminal Arrangement/Internal Connection (Bottom View)
Standard Models
(AC/DC Coil)
MKS2P(I)
4
5
3
4
6
2
7
1
MKS2P(I)-2
5
3
6
2
8
7
1
MKS3P(I)
6
5
10
2
MKS2P(I)N
4
MKS2P(I)N-2
5
4
6
3
6
2
7
2
7
1
8
1
6
5
MKS2P(I)N
4
MKS2P(I)N-2
5
4
9
3
6
3
6
2
7
2
7
1
8
1
6
MKS2P(I)N1
4
5
3
2
1
MKS2P(I)N1-2
4
6
3
7
2
8
5
6
7
1
6
5
MKS2P(I)-D
4
MKS2P(I)-D-2
5
4
6
3
6
2
7
2
7
1
8
1
6
3
MKS2P(I)1-D
4
MKS2P(I)1-D-2
5
4
6
3
6
2
7
2
7
1
8
1
6
5
MKS2P(I)N-D
4
5
3
4
6
2
7
1
MKS2P(I)N-D-2
3
8
6
2
7
1
8
6
5
3
9
2
10
11
General-purpose Relays
8
9
3
2
10
1
8
9
2
10
1
11
MKS3P(I)-D-5
6
7
4
8
3
9
2
10
11
MKS3P(I)1-D-5
6
7
8
4
9
3
2
10
11
MKS3P(I)N-D-5
6
5
7
7
3
1
MKS3P(I)N-D-2
6
6
4
11
4
11
MKS3P(I)N1-5
10
5
8
1
2
7
10
5
9
1
MKS3P(I)N-D
9
2
7
3
10
4
6
8
11
8
1
MKS3P(I)1-D-2
7
3
11
4
6
4
10
5
9
5
3
2
1
8
1
Models with
LED indicator
(DC Coil)
9
7
4
2
8
8
11
MKS3P(I)1-D
MKS3P(I)N-5
5
7
3
10
5
3
6
4
11
1
11
MKS3P(I)-D-2
5
9
9
10
2
10
1
8
1
Models with Diode
(DC Coil:
Reverse Polarity)
2
7
4
2
8
9
11
MKS3P(I)-D
5
8
3
10
8
5
7
7
3
1
MKS3P(I)N1-2
6
6
4
11
4
11
MKS3P(I)N-5
10
2
5
9
3
5
3
9
1
8
1
Standard Models
(DC Coil:
Standard Polarity)
3
7
4
2
8
8
11
MKS3P(I)N1
1
5
7
4
10
10
11
6
5
9
3
9
2
10
MKS3P(I)N-2
8
1
Models with
LED Indicator and
DIode
(DC Coil:
Reverse Polarity)
2
7
4
2
8
9
3
1
MKS3P(I)N
5
8
11
8
5
7
4
10
5
3
6
5
8
1
Models with Diode
(DC Coil:
Standard Polarity)
MKS3P(I)N-2
7
3
11
1
6
4
10
2
7
4
2
8
9
11
MKS3P(I)N
5
3
8
3
MKS3P(I)-5
5
7
4
9
3
6
5
8
1
Models with
LED Indicator
(AC Coil)
7
4
8
MKS3P(I)-2
7
8
4
9
3
2
11
MK-S New Model
10
1
11
7
Models with Varistor
(AC Coil)
MKS2P(I)-V
4
MKS2P(I)-V-2
5
4
5
3
6
3
6
2
7
2
7
1
8
1
MKS3P(I)-V
6
5
3
9
2
MKS2P(I)N-V
4
MKS2P(I)N-V-2
5
4
6
3
6
2
7
2
7
1
8
1
8
6
2
3
9
2
10
11
6
8
9
3
2
10
1
8
9
2
10
11
1
MKS3P(I)N-V-5
6
5
7
4
7
3
11
MKS3P(I)N-V-2
5
8
6
4
10
1
7
4
1
9
11
MKS3P(I)N-V
5
8
3
MKS3P(I)-V-5
5
7
4
10
5
3
6
5
8
1
Models with
LED indicator and
Varistor
(AC Coil)
7
4
8
MKS3P(I)-V-2
7
4
8
3
9
2
11
10
1
11
Safety Precautions
■ Safety Precautions for Correct Use
Installation
Mount the MK-S with the marking at the bottom.
Handling
Check the coil polarity of models with built-in diodes and wire them correctly
(DC operation coil).
Test Button
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only
the requirements for basic insulation are fulfilled.
8
General-purpose Relays MK-S
New Model
Warranty and Application Considerations
Read and Understand this Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any
questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other
period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS
UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in
the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty.
It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual
performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your
OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J168-E1-01
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Control Devices Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7109/Fax: (81)75-344-7149
0907 (0907)
Download PDF