ELECTRONIC CONTROLS
ECU-0809 Multi-Function, Programmable Controller
DESCRIPTION
European
Commission
(EC)
The ECU-0809 Controller is a compact and robust multi-function programmable controller designed to withstand the real-world environmental demands of the off-highway
mobile market. The ECU-0809 can be used in both centralized and distributed intelligence systems. It has a light, leakproof, chemical-resistant zinc/plastic enclosure,
indicator LED, Gore-Tex "breather" and 35-pin AMPSEAL connector.
The ECU-0809 has inputs and outputs that can be configured in multiple ways.
Input configuration can be set for up to 17 inputs consisting of Digital, Pulse, and
Analog inputs. Output configuration can be set for up to 8 PWM outputs with 4 current
feedbacks. All outputs are capable of driving up to 2 amps (closed loop) or 3 amps
(open loop.)
NOTE: Refer to Input/Output table below for pin configuration capability.
Refer to ECU-0809 Technical Reference Manual for specific data and ratings
of individual inputs and outputs.
RATINGS
POWER REQUIREMENTS:
Operating Voltage: 8.5 to 33 VDC
Idle Power Consumption: 1.3 Watts
Operating Current: 10 Amp maximum continuous current, with full external load.
Over-Voltage: 40 VDC maximum
FEATURES
• CE Certified, complies with WEEE,
European Community Directive
2002/96/EC/for waste electrical
and electronic equipment, RoHS,
European Community Directive
2011/65/EU restricting hazardous
substances, and certified to normal
automotive E17 (EMC) standards for
electromagnetic compatibility.
• Reliable operation in real-world
temperature conditions from
-40 to 85°C (-40 to 185°F)
• Robust, light, leakproof, chemicalresistant zinc/plastic enclosure.
• Three-point anchorage confirms firm
mounting, even on irregular surfaces.
• Inputs and outputs are protected
against shorts.
• Internal diagnostic capability to
detect overvoltage and overtemperature alarms.
• Signal LED for quick status check
and fault detection.
• Software developed with
CoDeSys v2.3 Programming Tool.
REFERENCE VOLTAGES:
(2) x +5 VDC Potentiometer Reference: 270 mA DC
COMMUNICATION:
(1) ISO CAN 2.0B Interface: CANopen, J1939, or user-programmable.
PROCESSING and MEMORY:
Microprocessor: 16/32-bit at 100 MHz
Flash ROM: 1600 Bytes
SRAM: 138 Kbyte (112 kbyte for PLC open application variables)
FRAM (Non-Volatile Memory): 2 Kbytes
ENVIRONMENTAL RATINGS:
Operating and Storage Temperature: - 40 to 85°C (-40 to 185°F)
Water Resistance: meets IP67 standards
Humidity Tolerance: Rel. Humidity > 90% from +25°C to +55°C
(per IEC 60068-2-30 Test Db)
Radiated Immunity: 20 to 2000 MHz at 30 V/m (per ISO 11452-2)
Vibration: 3.54 Grms random from 10 to 500 Hz (per IEC 60068-2-64 Test Fh)
Shock: 100 m/s2 peak (per IEC 60068-2-27 and -29 Tests Ea and Eb)
Corrosion: 5% NaCl for 24 hours at +35°C (per ISO 9227)
INPUTS / OUTPUTS — 21 Total
Max I/O
Count
Digital In
(SWG)
8
x
Digital In
(SWB)
5
x
4
x
Pulse
Input
Analog
Input
PWM
(Source)
Digital Out
(Source)
x
x
8
8
x
x
4
21
Current
Feedback
x
8
9
5
4
4
Note: The ECU-0809 has inputs and outputs that can be configured in multiple ways. For more information, consult the
ECU-0809 Technical Reference Manual.
3.505.3
®
HYDRAFORCE.com
HYDRAFORCE
®
ECU-0809 Multi-Function, Programmable Controller
DIMENSIONS
PIN ASSIGNMENTS
0.05
1.0
4.33
115.0
5.43
138.0
All Dimensions
for reference only.
1.75
44.5
3.46
88.0
4.25
108.0
Mounting Holes
Dia. 0.22
5.5
Weight: 0.97 lbs./0.44 kg.
MOUNTING
NOTE: When mounting the ECU-0809, be sure to mount
with the plug facing down or to the side. Do not mount the
unit in a position where the connector side is facing up.
Pin
Connector 1 Pin Function
Type
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.14
1.15
1.16
1.17
1.18
1.19
1.20
1.21
1.22
1.23
1.24
1.25
1.26
1.27
1.28
1.29
1.30
1.31
1.32
1.33
1.34
1.35
Power Ground
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Ground
CAN 1 HIGH
CAN 1 HIGH
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Digital Input/PWM Output/Digital Output
Loader BSL (For Factory Use Only)
Digital Input/Pulse Input, 12K GND
Digital Input/Pulse Input, 12K GND†
Ground
CAN 1 LOW
CAN 1 LOW
CAN 1 LOW_Terminator
Digital Input/Analog Input, 82.2K220 GND
Digital Input/Analog Input, 82.2K220 GND
Feedback/Analog Input 0.1 GND
Feedback/Analog Input 0.1 GND
VSUPPLY (+8.5 to 33 VDC)
Digital Input/Pulse Input, 12K GND
Digital Input/Pulse Input, 12K GND†
Digital Input/Pulse Input, 12K GND†
+5 VDC Reference ‡
+5 VDC Reference ‡
Ground
Digital Input/Analog Input, 82.2K220 GND
Digital Input/Analog Input, 82.2K220 GND
Ground
Feedback/Analog Input 0.1 GND
Feedback/Analog Input 0.1 GND
—
I/O
I/O
—
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
Input
Input
—
I/O
I/O
I/O
Input
Input
FB
FB
—
Input
Input
Input
—
—
—
Input
Input
—
FB
FB
†
The pin cannot read pulse width or frequency
‡Pins 1.28 and 1.29 are in parallel. Max supply current is 270mA
TO ORDER
Controller: Model ECU-0809 Part No. 4000350
AmpSeal Connector: 35-pin, Part No. 4000381
AmpSeal Socket/Plug: Sockets Gold (100 pc.) Part No. 4000369; Sealing Plugs (100 pc.) Part No. 4000370
Programming Software: CoDeSys Version 2.3
USB-CAN Adaptor: Part No. 4000371
®
HYDRAFORCE.com
3.505.4
Download PDF