UL 35-12 12V 35AH General UL35 -12 Physical Specification Part Number: UL35-12 Length: 195 ± 2 mm ( 7.68 inches ) Width: 130 ± 2 mm ( 5.12 inches ) Container Height: 164 ± 2 mm ( 6.46 inches ) Total Height (with terminal): 178 ± 2 mm ( 7.01 inches ) Approx 11.2kg Approx Weight: Specifications Terminal Type Container Material Rated Capacity Nominal Voltage 12V Nominal Capacity (20HR) 35AH Standard Terminal F5 Optional Terminal F2 / F6 / F10 Standard Option ABS Flame Retardant Option (FR) ABS (UL94:VO) 35.0 AH/1.75A (20hr,1.80V/cell, 25°C / 77°F) 32.6 AH/3.26A (10hr,1.80V/cell, 25°C / 77°F) 29.7 AH/5.95A (5hr,1.75V/cell, 25°C / 77°F) 26.8 AH/8.93A (3hr,1.75V/cell, 25°C / 77°F) 22.0 AH/22.0A (1hr,1.60V/cell, 25°C / 77°F) Max Discharge Current 525A (5s) Internal Resistance Approx 11mΩ Discharge Characteristics Operating Temp. Range Discharge: -15 ~ 50°C (5 ~ 122°F) Charge: 0 ~ 40°C (5 ~ 104°F) Storage: -15 ~ 40°C (5 ~ 104°F) Nominal Operating Temp. Range 25 ± 3°C (77 ± 5°F) Cycle Use Inital Charging Current less than 10.5A.Voltage 14.4V ~ 15.0V at 25°C (77°F) Temp. Coefficient -30mV/°C No limit on Initial Charging Current Voltage Standby Use 13.5V ~ 13.8V at 25°C (77°F) Temp. Coefficient -20mV/°C Capacity affected by Temperature 40°C (104°F) 103% 25°C (77°F) 100% 0°C (32°F) 86% Design Floating Life at 20°C 10 Years Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher temperatures the time interval will be shorter. Dimensions 31 0. [ 8 3 [0. 118] 1 R0 .5 [R0 79 ] 2 .0 ] Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: info@ultracell.co.uk www.ultracell.co.uk 130 2 .0 49 2 [R0 5] R2 180 2 17 [0.66 9] 164 2 F5 Terminal ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE ISO9001 Constant Current Discharge (Amperes) at 25 C (77 F ) 0 0 F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 66.7 51.2 42.4 36.7 28.3 20.9 17.6 10.4 8.14 6.62 5.40 4.69 3.78 3.16 1.73 1.80V/cell 89.5 65.4 51.2 43.3 33.4 24.3 19.7 11.4 8.76 7.07 5.80 5.03 4.01 3.26 1.75 1.75V/cell 100.9 71.9 56.0 46.6 34.7 25.2 20.6 11.8 8.93 7.23 5.95 5.16 4.08 3.34 1.77 1.70V/cell 111.1 78.3 59.7 49.0 36.1 26.2 21.3 12.1 9.17 7.42 6.10 5.27 4.13 3.41 1.80 1.65V/cell 122.5 84.5 63.5 52.0 38.1 26.9 21.8 12.3 9.57 7.68 6.27 5.39 4.20 3.48 1.82 1.60V/cell 135.1 91.8 67.9 55.4 40.3 28.0 22.0 12.8 9.86 7.92 6.48 5.50 4.24 3.52 1.83 8h 10h 20h Constant Power Discharge (Watts) at 25 0C (77 0F ) 5min F.V/Time 10min 15min 30min 20min 45min 1h 2h 5h 4h 3h 6h 1.85V/cell 121.9 94.5 79.1 69.1 54.0 40.1 34.0 20.2 15.9 12.9 10.6 9.21 7.46 6.25 3.43 1.80V/cell 161.8 119.4 94.3 80.5 62.8 46.3 37.8 21.9 17.0 13.7 11.3 9.84 7.89 6.43 3.46 1.75V/cell 178.6 129.1 101.7 85.8 64.6 47.6 39.4 22.6 17.2 14.0 11.6 10.1 8.01 6.60 3.49 1.70V/cell 191.2 137.5 107.1 89.4 66.9 49.3 40.5 23.2 17.7 14.4 11.8 10.3 8.11 6.72 3.55 1.65V/cell 207.9 147.0 113.0 94.3 70.0 50.1 41.1 23.4 18.4 14.8 12.1 10.5 8.22 6.85 3.60 1.60V/cell 224.0 156.0 118.9 99.4 73.4 51.9 41.3 24.2 18.8 15.2 12.5 10.7 8.28 6.91 3.61 Float Charging Characteristics Discharge Characteristics Terminal Voltage(V) 12V 6V 4V 2V Battery Battery Battery Battery V V V V 13.0 6.5 4.33 2.16 12.0 6.0 4.00 2.00 11.0 5.5 3.66 1.84 10.0 5.0 3.33 1.68 9.0 4.5 3.00 1.52 8.0 4.0 2.67 1.36 Charge Charging Charging Volume Current Voltage Temperature:25 0 C(77 0 F) % 120 110 0.4C 0.207C 100 0.093C 0.05C 90 80 50 0.20 0.15 0.10 40 30 3C 2 1 6 8 10 4 20 10 0 2C 60 40 20 2 4 6 8 10 20 15.0 7.5 14.0 7.0 13.0 6.5 12.0 6.0 0 Charging Voltage 11.0 5.5 (V) 2.50 Charged Volume 2.33 Charge Voltage (Constant 2.25v/cell) 2.17 After 50% Discharge 2.00 After 100% Discharge 0.05 1.83 Charging Current 0 0 H Min temperature25 C 0.25 70 60 0.628C 1C 0.10CA-2.25V/cell (V) (V) (XCA) 8 4 Discharge Time 12 16 20 28 24 32 36 40 Charging Time (Hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 120 Capacity % 80 Life (years) A 0 .0 5 C A 0 .1 C 100 0 .2 C A 60 1 .0 C A 40 2 .0 C 20 0 -20 -10 10 0 A 1 3. 0C A 20 30 10 40 0.1 50 10 Temperature(0C) Cycle Life in Relation to Depth of Discharge Remaining Capacity (%) 100 Capcity(%) 80 40 30% DOD Ambient Termperature: 25oC (77oF) 20 0 0 200 400 600 800 1000 1200 Number of Cycles 2 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: info@ultracell.co.uk www.ultracell.co.uk 100C 80 250C 60 60 A B 300C 400C 40 C 20 0 50% DOD 50 100 120 100% DOD 40 Temperature (C) Self Discharge Characteristics Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 60 30 20 0 2 4 6 8 10 Storage Time (Months) 12 A No supplementary required (Carryout supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use. Optional charging way as below: 1. Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell. 2. Charged for above 20 hours at limited current 0.25CA and constant voltage 2.25Vcell. 3. Charged for 8 ~ 10 hours at limited current 0.05 CA. C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE ISO9001