LED Illuminated Wall Fixture MRI Compatible

Illuminated Wall Fixture
( Part No. 800-410)
LED Illuminated Wall Fixture
MRI Compatible
Product Description
A panelized, non-ferrous, wall light fixture for use as an interior design
feature anywhere within a Healthcare Facility including MRI scan
rooms. The illuminated wall fixture is available in warm white or with
color changing RGB LED lights.
Features
LEDs
Dimensions
•
•
•
•
•
(16) 1m LED Light Strips
Warm White or RGB
12VDC, 160 watts
Prewired
•
90”h x 48”w x 7”d (Assembled)
(2286 x 1219 x 176mm)
160 lbs. (72.5kg)
Electrical Box
Lens
•
•
•
•
Installation
Uniform LED Light Diffusing Polymer
Applied Artwork Image Graphics
Textured Surface
•
•
Accessible, ½” & ¾” Knockouts
Direct Wall Attachment Tabs
Floor Bearing
Housing
One Year Limited Warranty
•
•
•
Rustproof Aluminum
Welded Construction
•
Trim
•
Complete Fixture
Approval Listings
ETL/cUL/CE
Laminated Poplar
Circuit Diagram
PDC FACILITIES, INC
700 Walnut Ridge Drive Hartland, WI 53029
262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com
Page 1 of 4
SPC-800-410 Rev F
Illuminated Wall Fixture
( Part No. 800-410)
Physical Properties
Dimensions (Assembled): 90”h x 48”w x 6.9”d (2286 x 1219 x 176mm) Weight: 160 lbs. (72.5kg)
PDC FACILITIES, INC
700 Walnut Ridge Drive Hartland, WI 53029
262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com
Page 2 of 4
SPC-800-410 Rev F
Illuminated Wall Fixture
( Part No. 800-410)
Installation
•
Elevation & Section
PDC FACILITIES, INC
700 Walnut Ridge Drive Hartland, WI 53029
262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com
Page 3 of 4
SPC-800-410 Rev F
Illuminated Wall Fixture
( Part No. 800-410)
Installation
• Detail Section at Top of Panel
PDC FACILITIES, INC
700 Walnut Ridge Drive Hartland, WI 53029
262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com
Page 4 of 4
SPC-800-410 Rev F
Warm White LED Strip
( Part No. 560-121 )
Warm White Rigid Bar LED Light Strip
MRI Compatible
Product Description
A non-ferrous, LED light strip for use within a fixture or under cabinet mounting as an interior architectural design
lighting package. PDC LED Light Strips can be used anywhere within a Health Care Facility including MRI Scan
Rooms.
Specifications
Material
Electrical Input


Housing: aluminum
12 VDC, 11.6 Watts, 0.97Amps
LEDs
Dimension






Lumens: 853.5
Efficacy: 72.99
Color Rendering Index: 64.31
Color Related Temp: 3,187
60 LED’s / 1m (3.28’)
1m / 3.28’
Three Year Limited Warranty

Complete Component
Approval Listings
ETL / UL / CSA / CE

PDC FACILITIES, INC
700 Walnut Ridge Drive Hartland, WI 53029
262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com
Page 1 of 1
SPC-560-121 Rev B Test #: L04121001
Date: 4/3/2012
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
LM-79 Test Summary
Manufacturer:
Model Number:
Total Lumens:
Input Voltage (VDC):
Input Current (Amp):
Input Power (W):
Input Power Factor:
Efficacy:
Color Rendering Index (CRI):
Correlated Color Temperature (CCT):
Chromaticity Coordinate x:
Chromaticity Coordinate y:
Ambient Temperature (oF):
Stabilization Time (Hours):
Total Operating Time (Hours):
PDC FACILITIES
560-121
853.50
12.00
0.97
11.69
N.A.
72.99
64.31
3187
0.4255
0.4025
77.0
0:30
0:50
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 2 of 4
Test #: L04121001
Date: 4/3/2012
W/m2nm
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
Spectral Irradiance
3.50E‐01
3.00E‐01
2.50E‐01
2.00E‐01
1.50E‐01
1.00E‐01
5.00E‐02
0.00E+00
380
Wavelength
W/m2nm
380
390
400
410
420
430
0.0022
0.0010
0.0006
0.0021
0.0085
0.0366
CRI & CCT
x
0.4255
y
0.4025
u'
0.2439
v'
0.5190
CRI
64.31
CCT
3187
Duv
0.24657
0
24657
R Values
R1
58.95
R2
76.06
R3
89.44
R4
57.27
R5
57.14
R6
63.79
R7
75.57
R8
36.26
R9
‐56.32
R10
43.61
R11
46.13
R12
30.73
R13
61.70
R14
93.89
430
440
450
460
470
480
490
500
480
0.1076
0.1938
0.1111
0.0562
0.0312
0.0281
0.0427
530
580
Wavelength(nm)
510
520
530
540
550
560
570
0.0710
0.1033
0.1403
0.1790
0.2187
0.2546
0.2847
580
590
600
610
620
630
640
630
680
0.3001
0.3001
0.2928
0.2568
0.2258
0.1876
0.1536
730
650
660
670
680
690
700
710
0.1172
0.0918
0.0718
0.0543
0.0405
0.0311
0.0233
780
720
730
740
750
760
770
780
0.0181
0.0139
0.0109
0.0083
0.0064
0.0064
0.0044
CIE 1931 Chromaticity Diagram
Y 0.9
520
0.8
530
540
510
0.7
550
560
06
0.6
570
500
0.5
580
590
0.4
0.4255, 0.4025
0.3
600
610
620
630
640
650
700
490
0.2
480
0.1
470
460
440
430
380
0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
X
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 3 of 4
Test #: L04121001
Date: 4/3/2012
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
Test Methods
Photometric Measurements - Goniophotometer
A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each
angle of distribution as defined by IESNA for the appropriate fixture type.
Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the
fixture. Temperature is maintained at 25 oC throughout the testing process and the sample is stabilized for at least
30mins and longer as necessary for the sample to achieve stabilization.
Electrical measurements are measured using the listed equipment.
Spectral Measurements - Integrating Sphere
A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to
measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each
l
Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the
fixture. Temperature is maintained at 25 oC throughout the testing process and the sample is stabilized for at least
30mins and longer as necessary for the sample to achieve stabilization.
Electrical measurements are measured using the listed equipment.
Test Report Released by:
Test Report Reviewed by:
Joseph Shin
Engineering Manager
Steve Kang
Quality Assurance
*Attached are photometric data reports. Total number of pages: 10
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 4 of 4
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-2002
[TEST] L04121001
[TESTLAB] LIGHT LABORATORY, INC.
[ISSUEDATE] 4/3/2012
[MANUFAC] PDC FACILITIES
[LUMCAT] 560-121
[LUMINAIRE] 39-5/16"L. X 9/16"W. X 1/4"H. LED BAR
[MORE] 20 LED MODULES WITH 1-15/16" SPACING,
[MORE] EACH MODULE HAS 3 WARM WHITE LEDS WITH 21/32" SPACING,
[MORE] 60 LEDS TOTAL
[LAMPPOSITION] 0,90
[LAMPCAT] WARM WHITE LED
[OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND
[MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS.
[_POWER SUPPLY] 12VDC CONSTANT VOLTAGE SOURCE
[_INPUT] 12VDC, 11.69W
[_TEST PROCEDURE] IESNA:LM-79-08
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criterion (0-180)
Spacing Criterion (90-270)
Spacing Criterion (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
N.A. (absolute)
N.A. (absolute)
854
N.A.
73
11.69
1.00
Direct
1.28
1.28
1.40
Rectangular
3.28 ft
0.05 ft
0.00 ft
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
LUMINANCE DATA (cd/sq.m)
Angle In
Degrees
Average
0-Deg
Average
45-Deg
Average
90-Deg
45
55
65
75
85
18656
18176
16970
14552
9488
18574
18066
16828
14381
9379
18326
17657
16357
13683
8076
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
CANDELA TABULATION
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
292.688
291.838
288.332
282.400
274.791
264.223
251.355
236.650
220.384
201.177
180.624
158.991
134.500
109.370
82.013
57.439
33.048
12.611
0.000
22.5
292.688
291.530
288.174
282.329
274.242
263.463
251.392
236.729
219.545
201.347
180.811
157.923
133.088
109.706
83.043
56.359
32.749
12.686
0.000
45.0
292.688
291.435
287.891
281.948
274.400
263.592
250.665
236.335
219.562
200.296
179.378
158.031
133.541
108.460
82.258
56.762
32.450
12.466
0.000
67.5
292.688
291.626
288.058
282.263
274.059
263.592
251.118
236.114
218.797
199.906
179.831
156.868
132.710
109.037
82.125
55.623
32.159
11.859
0.000
90.0
292.688
291.040
287.111
281.187
272.738
261.722
249.212
234.224
216.637
197.621
176.836
154.447
130.512
105.424
79.645
54.008
30.157
10.734
0.000
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
228.82
376.50
671.31
853.50
0.00
0.00
0.00
0.00
853.50
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
26.80
44.10
78.70
100.00
0.00
0.00
0.00
0.00
100.00
Total Luminaire Efficiency = N.A.%
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
27.71
79.65
121.46
147.67
154.41
140.40
107.03
59.76
15.40
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 4
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
0
1
2
3
4
5
6
7
8
9
10
119 119 119 119
109 104 99 96
99 90 83 78
90 79 71 64
82 70 61 54
75 62 53 47
70 56 47 41
65 51 42 36
60 46 38 32
56 43 34 29
53 39 31 26
116 116 116 116
106 102 98 94
96 88 82 77
87 78 70 64
80 69 60 54
73 61 53 46
68 55 47 41
63 50 42 36
58 46 38 32
55 42 34 29
51 39 31 26
111 111 111
97 94 91
85 80 75
75 68 63
66 59 53
59 52 46
53 46 40
49 41 35
44 37 32
41 34 28
38 31 26
106 106 106
93 91 88
82 77 73
72 66 62
64 58 53
57 51 45
52 45 40
47 40 35
43 36 31
40 33 28
37 30 26
102 102 102
90 88 86
79 75 72
69 65 60
62 56 52
55 50 45
50 44 39
46 40 35
42 36 31
39 33 28
36 30 26
100
84
69
58
50
43
37
33
29
26
24
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 5
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L04121001.IES
POLAR GRAPH
293
220
146
3
73
2
1
Maximum Candela = 292.688 Located At Horizontal Angle = 0, Vertical Angle = 0
# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) : BLUE
# 2 - Vertical Plane Through Horizontal Angles (90 - 270) : MAGENTA
# 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) : RED
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 6
Download PDF
Similar pages