LC1D25G7 - Schneider Electric

LC1D25G7
Product data sheet
Characteristics
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V
25 A - 120 V AC coil
Product availability : Stock - Normally stocked in distribution facility
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Price* : 151.00 USD
Main
Range
TeSys
Product name
TeSys D
Product or component type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC-1
AC-3
AC-4
Poles description
3P
Pole contact composition
3 NO
System Voltage
<= 300 V DC power circuit
<= 690 V AC 25...400 Hz power circuit
[Ie] rated operational current
25 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
40 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
Motor power kW
11 kW at 380...400 V AC 50/60 Hz AC-3
15 kW at 500 V AC 50/60 Hz AC-3
15 kW at 660...690 V AC 50/60 Hz AC-3
5.5 kW at 220...230 V AC 50/60 Hz AC-3
11 kW at 415...440 V AC 50/60 Hz AC-3
5.5 kW at 400 V AC 50/60 Hz AC-4
Motor power hp
2 hp at 115 V AC 50/60 Hz 1 phase motors
7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors
3 hp at 230/240 V AC 50/60 Hz 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz 3 phases motors
15 hp at 460/480 V AC 50/60 Hz 3 phases motors
20 hp at 575/600 V AC 50/60 Hz 3 phases motors
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
120 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Feb 19, 2018
1
Overvoltage category
III
[Ith] conventional free air thermal
current
40 A at <= 140 °F (60 °C) power circuit
10 A at <= 140 °F (60 °C) signalling circuit
Irms rated making capacity
450 A at 440 V power circuit conforming to IEC 60947
140 A AC signalling circuit conforming to IEC 60947-5-1
250 A DC signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
450 A at 440 V power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
120 A <= 104 °F (40 °C) 1 min power circuit
240 A <= 104 °F (40 °C) 10 s power circuit
380 A <= 104 °F (40 °C) 1 s power circuit
50 A <= 104 °F (40 °C) 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Associated fuse rating
40 A gG at <= 690 V coordination type 2 power circuit
63 A gG at <= 690 V coordination type 1 power circuit
10 A gG signalling circuit conforming to IEC 60947-5-1
Average impedance
2 mOhm at 50 Hz - Ith 40 A power circuit
[Ui] rated insulation voltage
600 V power circuit certifications CSA
600 V power circuit certifications UL
690 V power circuit conforming to IEC 60947-4-1
690 V signalling circuit conforming to IEC 60947-1
600 V signalling circuit certifications CSA
600 V signalling circuit certifications UL
Electrical durability
1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Power dissipation per pole
3.2 W AC-1
1.25 W AC-3
Protective cover
With
Mounting support
Plate
Rail
Standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with
cable end
Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1.5...10 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1...10 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible with cable end
2
Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: solid without cable end
Tightening torque
Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver Philips No 2
Operating time
4...19 ms opening
12...22 ms closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability
15 Mcycles
Operating rate
3600 cyc/h at <= 140 °F (60 °C)
Complementary
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz
0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz
0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
Inrush power in VA
70 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz
70 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz
Hold-in power consumption in VA
7.5 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
7 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
Heat dissipation
2...3 W at 50/60 Hz
Auxiliary contacts type
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
Minimum switching current
5 mA signalling circuit
Minimum switching voltage
17 V signalling circuit
Non-overlap time
1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
Insulation resistance
> 10 MOhm signalling circuit
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Pollution degree
3
Ambient air temperature for operation
23...140 °F (-5...60 °C)
Ambient air temperature for storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature
around the device
-40...158 °F (-40...70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating in temperature
Fire resistance
1562 °F (850 °C) conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz
Vibrations contactor closed 4 Gn, 5...300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 8 Gn for 11 ms
Height
3.35 in (85 mm)
Width
1.77 in (45 mm)
Depth
3.62 in (92 mm)
Product weight
0.82 lb(US) (0.37 kg)
Ordering and shipping details
Category
22345 - CTR,D-LINE,OPEN,NONREV-NEW
Discount Schedule
I12
GTIN
00785901207153
Nbr. of units in pkg.
1
3
Package weight(Lbs)
0.92000000000000004
Returnability
Y
Country of origin
ID
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Compliant - since 0627 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Available
Contractual warranty
Warranty period
4
18 months
Download PDF