PSX60 &100W-NO ™
INSTALLATION INSTRUCTIONS
NON-DIMMING
24V DC OUTPUTS
drawing number 121853
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
STEP 1. INSTALL HOUSING
STEP 2. OPEN BOX
MOUNTING HOLES ON THE BOTTOM OF THE CBX
REQUIRED TOOL:
#3 PHILLIPS
SCREWDRIVER
3
10 "
8
[264mm]
PROVIDED TOOL:
FLAT SCREWDRIVER
(FOR BLOCK
CONNECTOR WIRING)
NOTICE
63"
8
[162mm]
INSTALL HOUSING
WITH COVER FACING
UP WHEN OPEN
NOTICE
KEEP 5" [127mm]
CLEARANCE ON ALL SIDES
5"
[127mm]
USE 1/4”-20 UNC OR M6 ANCHORING BOLTS THAT ARE APPROPRIATE FOR USE
WITH YOUR MOUNTING SURFACE (PROVIDED BY INSTALLING CONTRACTOR)
2X
4X
AS DELIVERED
!
WARNING
DO NOT EXCEED CONTROL
SPECIFIED VOLTAGE.
WARNING
!
DO NOT USE IF PARTS OR
CONNECTORS ARE DAMAGED.
!
!
WARNING
NOTICE
SEPARATION OF FIELD INSTALLED POWER
LIMITED CIRCUIT (DIMMING/CONTROL)
WIRING FROM THE BRANCH CIRCUIT
WIRING IN THE OUTLET BOX ARE TO BE
MADE IN ACCORDANCE WITH LOCAL
AND/OR NATIONAL ELECTRICAL
INSTALLATION CODES.
CONSULT BLOCK CONNECTOR
MARKINGS FOR APPROPRIATE USAGE
POWER INPUT:
RECOMMENDED WIRE GAUGE: 16 AWG [1.307mm²]
RANGE: 20-12 AWG [0.519-3.301mm²]
WARNING
American Color Code
DISCONNECT POWER BEFORE
INSTALLING OR SERVICING TO
AVOID ELECTRICAL SHOCK.
CAUTION
UNAUTHORIZED FIELD REPAIRS
WILL VOID WARRANTY.
WIRE COLOR /
USE
GREEN
WHITE
BLACK
GROUND
NEUTRAL
LIVE 100-277V
CE Color Code
WIRE COLOR /
CAUTION
USE
YELLOW/GREEN GROUND
BLUE
NEUTRAL
BROWN
LIVE 220/240V
THE USE OF RTV SILICONE IS
RECOMMENDED TO SEAL ALL
ENTRY POINTS (PRESSURE GLANDS,
CONDUIT). THIS WILL ENSURE THE
ASSEMBLY IS WATERTIGHT.
Neutral connection required
American Color Code Shown
CONNECTION STEPS
NOTICE
USE A 5/16" [8mm] STRIP LENGTH FOR CONNECTIONS
5
"
16
[8mm]
STEP 3. 100-277V INPUT
STEP 4. OUTPUT TO FIXTURES (UP TO 6)
LOCKING CONNECTION
LOCKING CONNECTION
SUITABLE STRAIN RELIEF
DEVICE TO BE PROVIDED
BY INSTALLING CONTRACTOR.
100-277V
INPUT
GROUND (GREEN)
NEUTRAL (WHITE)
LIVE (BLACK)
24V DC
OUTPUT
TO FIXTURE
(TYPICAL 2
CONDUCTOR CABLE)
24V + (BLACK)
24V - (WHITE)
Bottom half of PSX housing shown
FINAL
STEP 6. CLOSE BOX
OUTPUT QUANTITY DEPENDS
ON PROJECT LAYOUT.
24V DC
OUTPUT
TO FIXTURE
(TYPICAL 2
CONDUCTOR
CABLE)
UP TO 6 OUTPUTS TO FIXTURES.
24V + (BLACK)
24V - (WHITE)
100-277V
INPUT
GROUND (GREEN)
NEUTRAL (WHITE)
LIVE (BLACK)
ADD UP ALL FIXTURE RUN
LOADS AND BE SURE THEY DO
NOT EXCEED THE
CAPACITY OF THE PSX.
24V DC OUTPUTS TO FIXTURE
(TYPICAL 2 CONDUCTOR CABLE)
p.1/2
2017.11.08
MG - R4
1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
info@lumenpulse.com www.lumenpulse.com
Copyright © Lumenpulse Group Inc. 2017
Confidential and proprietary
Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
2X
PSX60 &100W-NO ™
INSTALLATION INSTRUCTIONS
NON-DIMMING
24V DC OUTPUTS
drawing number 121853
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
STEP 1. INSTALL HOUSING
STEP 2. OPEN BOX
MOUNTING HOLES ON THE BOTTOM OF THE CBX
REQUIRED TOOL:
#3 PHILLIPS
SCREWDRIVER
3
10 "
8
[264mm]
PROVIDED TOOL:
FLAT SCREWDRIVER
(FOR BLOCK
CONNECTOR WIRING)
NOTICE
63"
8
[162mm]
INSTALL HOUSING
WITH COVER FACING
UP WHEN OPEN
NOTICE
KEEP 5" [127mm]
CLEARANCE ON ALL SIDES
5"
[127mm]
USE 1/4”-20 UNC OR M6 ANCHORING BOLTS THAT ARE APPROPRIATE FOR USE
WITH YOUR MOUNTING SURFACE (PROVIDED BY INSTALLING CONTRACTOR)
2X
4X
AS DELIVERED
!
WARNING
DO NOT EXCEED CONTROL
SPECIFIED VOLTAGE.
WARNING
!
DO NOT USE IF PARTS OR
CONNECTORS ARE DAMAGED.
!
!
WARNING
NOTICE
SEPARATION OF FIELD INSTALLED POWER
LIMITED CIRCUIT (DIMMING/CONTROL)
WIRING FROM THE BRANCH CIRCUIT
WIRING IN THE OUTLET BOX ARE TO BE
MADE IN ACCORDANCE WITH LOCAL
AND/OR NATIONAL ELECTRICAL
INSTALLATION CODES.
CONSULT BLOCK CONNECTOR
MARKINGS FOR APPROPRIATE USAGE
POWER INPUT:
RECOMMENDED WIRE GAUGE: 16 AWG [1.307mm²]
RANGE: 20-12 AWG [0.519-3.301mm²]
WARNING
American Color Code
DISCONNECT POWER BEFORE
INSTALLING OR SERVICING TO
AVOID ELECTRICAL SHOCK.
CAUTION
UNAUTHORIZED FIELD REPAIRS
WILL VOID WARRANTY.
WIRE COLOR /
USE
GREEN
WHITE
BLACK
GROUND
NEUTRAL
LIVE 100-277V
CE Color Code
WIRE COLOR /
CAUTION
USE
YELLOW/GREEN GROUND
BLUE
NEUTRAL
BROWN
LIVE 220/240V
THE USE OF RTV SILICONE IS
RECOMMENDED TO SEAL ALL
ENTRY POINTS (PRESSURE GLANDS,
CONDUIT). THIS WILL ENSURE THE
ASSEMBLY IS WATERTIGHT.
Neutral connection required
American Color Code Shown
CONNECTION STEPS
NOTICE
USE A 5/16" [8mm] STRIP LENGTH FOR CONNECTIONS
5
"
16
[8mm]
STEP 3. 100-277V INPUT
STEP 4. OUTPUT TO FIXTURES (UP TO 6)
LOCKING CONNECTION
LOCKING CONNECTION
SUITABLE STRAIN RELIEF
DEVICE TO BE PROVIDED
BY INSTALLING CONTRACTOR.
100-277V
INPUT
GROUND (GREEN)
NEUTRAL (WHITE)
LIVE (BLACK)
48V DC
OUTPUT
TO FIXTURE
(TYPICAL 5
CONDUCTOR CABLE)
48V - (WHITE)
48V + (BLACK)
(GROUND GREEN)
Bottom half of PSX housing shown
!
FINAL
Always tie both data
wires together
STEP 5. CLOSE BOX
OUTPUT QUANTITY DEPENDS
ON PROJECT LAYOUT.
UP TO 6 OUTPUTS TO FIXTURES.
48V DC
OUTPUT
TO FIXTURE
(TYPICAL 5
CONDUCTOR
CABLE)
100-277V
INPUT
GROUND (GREEN)
NEUTRAL (WHITE)
LIVE (BLACK)
ADD UP ALL FIXTURE RUN
LOADS AND BE SURE THEY DO
NOT EXCEED THE
CAPACITY OF THE PSX.
48V - (WHITE)
48V + (BLACK)
(GROUND GREEN)
48V DC OUTPUTS TO FIXTURE
(TYPICAL 5 CONDUCTOR CABLE)
p.2/2
2017.11.08
MG - R4
1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
info@lumenpulse.com www.lumenpulse.com
Copyright © Lumenpulse Group Inc. 2017
Confidential and proprietary
Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
2X
Download PDF
Similar pages