Oriental Motor PCM5-C IP66 Motor Cover Operating Manual

Add to My manuals
1 Pages

advertisement

Oriental Motor PCM5-C IP66 Motor Cover Operating Manual | Manualzz

HM-5152-2

OPERATING MANUAL

Motor Cover

PCM5

PCM5-C

Thank you for purchasing an Oriental Motor product.

Only qualified personnel of electrical and mechanical engineering should work with the product.

Use the product correctly after thoroughly reading the section "Safety precautions."

Before use

The product described in this manual has been designed and manufactured to be incorporated in general industrial equipment. Do not use for any other purpose.

Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to observe this warning.

Safety precautions

The precautions described below are intended to prevent danger or injury to the user and other personnel through safe, correct use of the product. Use the product only after carefully reading and fully understanding these instructions.

Warning

Handling the product without observing the instructions that accompany a "Warning" symbol may result in serious injury or death.

• Do not use the product in explosive environments, in the presence of flammable gases, or near combustibles. Doing so may result in fire or injury.

• Do not use for any product other than applicable products. Doing so may result in electric shock or damage to equipment.

• When installing the motor, ground the Protective Earth Terminal of the motor.

Failure to do so may result in electric shock.

• Install securely based on the installation condition or mounting instruction.

Failure to do so may result in electric shock or damage to equipment.

• Do not forcibly bend or pull the cable. Doing so may result in electric shock or damage to equipment.

Precautions for use

• The watertight performance of the motor cover is designed assuming fresh water and tap water at normal temperature [+5 to +35 °C (+41 to +95 °F)]. Do not splash

• hot water or blow hot air.

• The motor cover cannot be used under water, and also cannot be washed by high water pressure.

• Tighten hexagonal socket head screws evenly so that the mounting surface of the motor cover and the mounting plate are in parallel. Check periodically if any of the tightened screws come loose. Re-tighten if the screw was loose.

Applicable product

• Series: 30 W, 60 W, 120 W type

• Series: 30 W, 60 W, 120 W type

Installation

Install the motor cover to a flat metal plate.

Installation conditions

• ••Operating ambient temperature: 0 to +40 °C (+32 to +104°F)

• Operating ambient humidity 85% or less

• Area that is free of explosive atmosphere or free of atmosphere which contains strong acids, strong alkali or organic solvents (ethyl chloride, methyl chloride, cresol, etc.)

• ••Area free of damp or ozonic atmosphere

• Area not exposed to direct sun

30 W and 60 W: 170 X 170 mm (6.69 X 6.69 in.) or larger

120 W: 250 X 250 mm (9.84 X 9.84 in.) or larger

Thickness: 5 mm (0.20 in.) Material: Aluminum alloy

Reference panel cut-out

[Unit: mm (in.)]

102 (4.02)

4×M5 or φ 5.5 ( φ 0.217) ∗

1

Center position for mounting a motor

1 Machining of mounting hole

M5: To secure with screws only

φ5.5 (φ0.217): To secure with screws and nuts

φ 20 ( φ 0.787) ∗

2

2 φ20 (φ0.787) is a hole size for when passing a cable and a grounding wire through the mounting plate.

With hole plug: PCM5

Housing of motor cover Attachments (supplied)

Hexagonal socket

head screws

4 pieces

Size: M5

Screw length 25 mm (0.98 in.)

(with washer)

Hole plug

(cap and rubber washer)

Gasket

Nuts

4 pieces

This gasket is a consumable part.

An estimated timing for replacement is approximately one year.

The gasket for replacement is provided as an accessory (sold separately).

Installation method

Installation methods are explained using the connector type motor as an example.

Put on the motor cover after passing the motor cable through the hole

of the mounting plate.

Secure to the mounting plate with the supplied hexagonal socket head

screws.

Mounting plate

Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)

Motor

Grounding wire

Cable

Grounding

Connect the grounding wire to the grounding terminal of the driver

or equipment. When connecting, do not pinch the grounding wire

between the motor cover and the mounting plate.

When watertight and dust-resistant performance is not needed

The motor cover can be installed as shown in the figure below.

Remove the hole plug to pass through the cable.

Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)

Round shaft type

Motor

Mounting plate

Grounding

Tightening torque for when attaching the hole plug again:

2.0 to 2.5 N·m (17.7 to 22 lb-in) memo

Before covering the motor with the motor cover, consider the bending of the cable as shown in the figure, and adjust the cable length to be stored in the motor cover. Do not forcibly pull the cable.

Specifications of motor cover

Housing of motor cover

Cable gland

Hole plug

Polycarbonate

(flammability grade UL94V-0)

Hexagonal socket head screw, nut Stainless steel

Gasket Nitrile butadiene rubber

Nylon 66 (flammability grade UL94V-2), ethylene propylene diene rubber

• RoHS Directive: The products do not contain the substances exceeding the restriction values of RoHS Directive (2011/65/EU).

With cable gland: PCM5-C

Housing of motor cover

Gasket

Attachments (supplied)

Hexagonal socket

head screws

4 pieces

Size: M5

Screw length 25 mm (0.98 in.)

(with washer)

Nuts

4 pieces

This gasket is a consumable part.

An estimated timing for replacement is approximately one year.

The gasket for replacement is provided as an accessory (sold separately).

Installation method

Installation methods are explained using the connector type motor as an example.

1

Pass the motor cable through

B , and put the motor

cover over the motor.

Mounting plate

Motor

Cable gland 1 piece

A : Rubber washer

Assembled with housing of motor cover

B : Cable gland

Supplied

C : Sealing insert

D : Clamping claw

C and D have been assembled.

E : Sealing nut

Applicable diameter of cable: φ6 to 10.5 mm

( φ0.24 to 0.41 in.)

Assembling the cable gland

1.

 

Pass the cable through

C

and

D

.

Detach assembled C and D .

Detach

D C

Install to the cable as shown in the right figure, and assemble

C with D .

Install in the direction shown in the figure.

Slit

A

B

C Install C to the cable.

Note

Securely assemble C and D .

Incomplete assembling may cause ingress of liquids.

Cable

D Pass the connector

(end) of the connection cable through D.

2.

 Pass the cable through

E

, and tighten to

B

.

2

Grounding

B

Grounding wire

Cable

Connect the grounding wire to the grounding terminal of the driver

or equipment. When connecting, do not pinch the grounding wire

between the motor cover and the mounting plate.

Assemble the cable gland.

Secure to the mounting plate with the supplied hexagonal socket head screws.

Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)

Round shaft type

Motor

E Tightening torque: 2.0 to 2.5 N·m

(17.7 to 22 lb-in)

Grounding

Cable

Mounting plate memo Before covering the motor with the motor cover, consider the bending of the cable as shown in the figure, and adjust the cable length to be stored in the motor cover. Do not forcibly pull the cable.

Note

If the once-tightened E is loosened, the assembling state for B and the motor cover will also come loose.

Tighten B and the motor cover using the specified torque in order to prevent ingress of liquids.

Tightening torque: 2.0 to 2.5 N·m (17.7 to 22 lb-in)

B

Cover

E

• Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided or referenced in this manual.

• Characteristics, specifications and dimensions are subject to change without notice.

• is a registered trademark or trademark of Oriental Motor Co., Ltd., in Japan and other countries.

© Copyright ORIENTAL MOTOR CO., LTD. 2017 Published in July 2017

• Please contact your nearest Oriental Motor office for further information.

Technical Support Tel:(800)468-3982

8:30

A.M.

to 5:00

P.M.

, P.S.T. (M-F)

7:30

A.M.

to 5:00

P.M.

, C.S.T. (M-F) www.orientalmotor.com

Tel:+55-11-3266-6018 www.orientalmotor.com.br

Schiessstraße 44, 40549 Düsseldorf, Germany

Technical Support Tel:00 800/22 55 66 22 www.orientalmotor.de

Tel:01256-347090 www.oriental-motor.co.uk

Tel:01 47 86 97 50 www.orientalmotor.fr

Tel:02-93906346 www.orientalmotor.it

4-8-1Higashiueno,Taito-ku,Tokyo 110-8536

Japan

Tel:03-6744-0361 www.orientalmotor.co.jp

Singapore Tel:1800-8420280 www.orientalmotor.com.sg

Tel:1800-806161 www.orientalmotor.com.my

Tel:1800-888-881 www.orientalmotor.co.th

Tel:+91-80-41125586 www.orientalmotor.co.in

Tel:0800-060708 www.orientalmotor.com.tw

Tel:400-820-6516 www.orientalmotor.com.cn

Korea Tel:080-777-2042 www.inaom.co.kr

Hong Kong Branch

Tel:+852-2427-9800

advertisement