www.contractorlighting.com
Batteries
01S-B12V9
(12V9Ah)
12V 9aH Sealed Lead Acid
SPECIFICATIONS
Nomial Voltage
12V
Nomial Capacity (20HR)
9AH
Dimension
Length
Width
Container Height
Total Height (with Terminal)
151+
-1mm (5.95 inches)
65+
-1mm (2.56 inches)
94.5+
-1mm (3.72 inches)
100+
-1mm (3.94 inches)
BATTE RY
Ma int en
an ce- fre
e Se ale d
CO NS TAN
C0 9A (12
Lea d-a cid
V9 AH )
Ba tte ry
OLTAG E
C
HA RG E
e s 13.
u5-1 3.8
y
d
14. 4-1 5.0 b
nV a
Less th
V
x es
an
heat above
the 50 C, ,o e l rp ir f o f
2.55 A
or i
ncine rate. , o nn otkodisass
osi i D
2.75 kg (6.06 lbs)
Approximate Weight
Terminal
Cyc le
Init ial
Warn ing:
TV
:
use :
current
:
t
S
O
embl
R . e,s
UL
T1 / T2
r
u
b
LISTED
NATIONAL BATTERY
Non-sp
BATTER Y MUST illable
BE RECYC
ABS
Container Material
n
R
LED
RY
SIGMA S BATTE
0
0
Rated Capacity
9.00 AH/0.425A
7.91 AH/0.791A
7.22 AH/1.45A
6.50 AH/2.17A
5.34 AH/5.34A
Max. Discharge Current
127.5A (5s)
Internal Resistance
Approx 18mȍ
Operating Temp. Range
Discharge : - 15~50 C (5~122 F)
0
0
Charge
: 0~40 C (32~104 F)
0
0
Storage : - 15~40 C (5~104 F)
Nominal Operating Temp. Range
0
0
25+
- 5 F)
- 3 C (77+
Emergency rst responder equipment
Initial Charging Current less than 2.55A. Voltage
Emergency lighting
(20hr,1.80V/cell,25 C/77 F)
0
0
(10hr,1.80V/cell,25 C/77 F)
0
0
(5hr,1.75V/cell,25 C/77 F)
0
0
(3hr,1.75V/cell,25 C/77 F)
0
0
(1hr,1.60V/cell,25 C/77 F)
APPLICATIONS
Uninterruptible Power Supply (UPS)
0
Cycle Use
0
Standby Use
Electric wheelchairs, scooters, bikes
0
Electronic apparatus and equipment
Alarm and security systems
0
0
14.4V~15.0V at 25 C (77 F) Temp. Coefficient -30mV/ C
Medical devices
No limit on Initial Charging Current Voltage
Electric carts
0
0
0
13.5V~13.8V at 25 C (77 F) Temp. Coefficient -20mV/ C
o
40 C
25oC
0 oC
Capacity affected by
Temperature
o
(104 F)
(77oF)
(32oF)
Telecom equipment
103%
100%
86%
Switchgear
Solar power systems
CONSTANT CURRENT DISCHARGE (AMPERES) AT 25°C (77°F)
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
16.2
12.4
10.3
8.90
6.88
5.07
4.27
2.53
1.98
1.61
1.31
1.14
0.918
0.767
0.421
1.80 V/cell
21.7
15.9
12.4
10.5
8.12
5.90
4.79
2.76
2.13
1.72
1.41
1.22
0.973
0.791
0.425
1.75 V/cell
24.5
17.5
13.6
11.3
8.43
6.12
5.01
2.86
2.17
1.76
1.45
1.25
0.990
0.812
0.429
1.70 V/cell
27.0
19.0
14.5
11.9
8.78
6.36
5.17
2.93
2.23
1.80
1.48
1.28
1.004
0.828
0.437
1.65 V/cell
29.7
20.5
15.4
12.6
9.26
6.52
5.29
2.98
2.32
1.86
1.52
1.31
1.020
0.845
0.443
1.60 V/cell
32.8
22.3
16.5
13.5
9.78
6.80
5.34
3.10
2.39
1.92
1.57
1.34
1.030
0.854
0.445
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
29.6
23.0
19.2
16.8
13.1
9.75
8.25
4.91
3.86
3.14
2.57
2.24
1.81
1.52
0.834
CONSTANT POWER DISCHARGE (WATTS) AT 25°C (77°F)
1.80 V/cell
39.3
29.0
22.9
19.5
15.2
11.2
9.19
5.32
4.13
3.34
2.75
2.39
1.92
1.56
0.841
1.75 V/cell
43.4
31.3
24.7
20.8
15.7
11.6
9.57
5.50
4.18
3.40
2.81
2.45
1.94
1.60
0.848
1.70 V/cell
46.4
33.4
26.0
21.7
16.2
12.0
9.84
5.62
4.29
3.49
2.88
2.49
1.97
1.63
0.863
1.65 V/cell
50.5
35.7
27.4
22.9
17.0
12.2
9.99
5.67
4.46
3.59
2.95
2.54
2.00
1.66
0.873
1.60 V/cell
54.4
37.9
28.9
24.1
17.8
12.6
10.0
5.89
4.57
3.69
3.03
2.59
2.01
1.68
0.877
www.contractorlighting.com
Batteries
12V 9aH Sealed Lead Acid
DIMENSIONS
T2 Termina l
2
65+
-1
43+
-1
C09A (12V9AH)
BATTERY
100+
-1
94.5+
-1
6.35 (0.25)
Unit: mm ( inche s )
Maintenance-free Sealed Lead-acid Battery
CONSTANT V OLTAGE C HARGE
: e s 13.5-13.8
u
y b d nV a t
Cycle
use:
14.4-15.0
V
Initial current:
Less than
2.55 A
S
Warning:
Risk o f
, explosion, or b
urns. Do not disassemble,
heat above the 50 C, or incinerate.
3.4 (0.134)
7.95 (0.313)
0.8 (0.031)
O
UL
R
LISTED
Non-spillable
B ATT ER Y M US T B E R EC YCL E D
NATIONAL BATTERY
FLOAT CHARGING CHARACTERISTICS
DISCHARGE CHARACTERISTICS
12V
6V
4V
2V
Battery Battery Battery Battery
ȳVȳ
ȳVȳ
ȳVȳ
ȳVȳ
13.0
6.5
4.33
151+
-1
Charge Charging Charging
Volume Current Voltage
Temperature : 25 0 C ( 77 0F)
2.16
Terminal Voltage (V)
%
12.0
6.0
4.00
2.00
11.0
5.5
3.66
1.84
10.0
5.0
3.33
1.68
9.0
4.5
3.00
1.52
0.093C 0.05C
0.207C
0.4C
1C
8.0
2.67
4.0
3C
1
2
4
2C
6 8 10
120
110
100
40 60
20
2
6 8 10
4
90
80
Min
H
15.0
7.5
14.0
7.0
2.33
Charge Voltage
( C onstant 2.25v/cell)
13.0
6.5
0.10
12.0
6.0
0.05
11.0
5.5
2.17
After 50% Discharge
2.00
After 100% Discharge
1.83
Charging Current
0
0
4
8
20
28
24
32
36
40
Charging Time (hours)
TEMP. EFFECTS IN RELATION TO BATTERY CAPACITY
EFFECTS OF TEMP. ON LONG TERM FLOAT LIFE
10
120
8
6
5
4
80
Life expectancy (year)
A
0 .0 5 C
A
0 .1 C
100
Capacity ȳ % ȳ
16
12
Discharge Time
0 .2 C A
60
1 .0 C A
40
2 .0 C
20
0
-20
A
3. 0C A
Charging voltage :
2.25V/cell
3
2
1
0.5
-10
0
10
30
20
40
50
30
86
20
68
0
Temperature ( C)
0
100
80
0
50%
DOD
200
400
600
800
1000
A
250C
B
60
0
30 C
400C
40
C
20
0
30%
DOD
2
4
6
8
10
12
Storage Time (Months)
Ambient Termperature:
25oC (77oF)
20
10 C
80
60
0
0
C
F
0
100
Remaining Capacity (%)
Ambient teperature:25 5 C
120
100%
DOD
0
SELF DISCHARGE CHARACTERISTICS
Testing condition
Discharging: current 0.17C (FV 1.7V/cell);
Charging: current 0.25C max, voltage 2.45V/cell;
Charging volume : 125% of discharged capacity.
40
50
122
40
104
Battery temperature
CYCLE LIFE IN RELATION TO DEPTH OF DISCHARGE
Capcity (%)
2.50
Charged Volume
0.15
10
0
20
(V)
0.20
50
40
30
20
1.36
temperature 25 C
0.25
70
60
0.628C
Charging
Voltage
0
0.10CA-2.25V/cell
(V)
(V)
(XCA)
A
No supplementary charge required
(Carry out supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use.Optional charging way as below:
1. Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
2. Charged for above 20 hours at limted current 0.25CA and constant volatge 2.45V/cell.
3. Charged for 8~10 hours at limted current 0.05CA .
C
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached.
1200
Number of Cycles
Download PDF
Similar pages