Origins Kitchen Faucet, S

Origins
®
Kitchen Faucet S-23 Series
Installation and Service Instructions
Installation
Caution: Be sure to turn off hot and cold water supplies before
installing or servicing faucet.
Step 1 If installing model with hose and spray, install hose
guide into hole in sink (normally the far right hole on four
hole sink). From underneath sink place washer then nut over
hose guide and secure to sink. Insert hose through hose guide
and up through middle hole from left in sink. Loosely install
the anchor bar (KN-23), spacer (KN-26) and nut (L-36) on the
mounting bolts and place gasket on base of faucet. From above
sink attach hose securely to nipple on base of faucet.
Step 2 Align faucet to sink by matching underside arrow
and word “FRONT” on base plate (KN-33) with front of sink.
Without straightening copper supplies insert through center
hole of sink and anchor bar/spacer/nut assemblies through
holes in sink. Secure faucet to sink by tightening nuts from
underside. (If sink surface is uneven use putty or sealant to
make proper seal under base.)
Step 3 Carefully straighten copper supplies to avoid kinking
tubing. Connect hot supply to left tube and cold supply to right
tube using appropriate connectors.
Step 4 It is very important to thoroughly flush the supply
lines to prevent foreign matter, i.e. copper chips, sand, stones,
etc. from damaging the sealing surfaces of cartridge. Remove
aerator and turn valve handle on to full cold position, open cold
supply. Without closing, turn handle to full hot and open hot
supply. Let water run in hot only and cold only positions long
enough to flush supply lines thoroughly. If equipped with a hose
and spray, direct spray head into sink and activate spray. Shut
off faucet and replace aerator. Check for leaks.
Step 5 The handle limit stop can be set to limit handle turn
to the hot position. The limit mechanism is factory set to allow
full handle travel. To adjust the limit stop, turn handle to the
full hot position and lift handle to open faucet approximately
half way to obtain a smooth flow for correct initial temperature
measurement.
Step 6 If when faucet is on and in full hot position and water
is too hot, shut water off, remove plug button (KN-157), loosen
set screw (L-22) and remove handle (KN-3RB or KN-3BRB),
lift limit stop using a small flat head screw driver and rotate
clockwise to lower temperature. If water is not hot enough,
rotate counter clockwise (See Figure 1 on reverse side). After
correct temperature is achieved, reattach handle, reversing
procedure above.
Cartridge Replacement (KN-4)
Step 1 Remove plug button (KN-157), loosen set screw (L-22)
and remove handle (KN-3RB or KN-3BRB).
Step 2 Engage tabs in cartridge wrench (LN-34) with slots in
compression ring (KN-2) and use screwdriver in wrench holes or
pliers on wrench and turn counter clockwise until compression
ring engages with cap (KN-1). Continue turning counter
clockwise so that cap/ring assembly is removed from the body
(KN-11).
Step 3 Remove cartridge and o-ring seal (KN-4).
Step 4 Install new cartridge while taking care to maintain
position of the o-ring seal at the base of the cartridge. Match
posts in base of cartridge with alignment holes in adapter plate
during assembly.
Step 5 Reassemble faucet in reverse fashion. Thread cap onto
body firmly by hand. Do not use a wrench which may damage
the finish. Tighten compression ring (KN-2) finger tight using
the wrench (LN-34) then 1/4 to 1/2 turn further. Set hot water
limit stop in accordance with installation step 6 above.
Diverter replacement (KN-169)
1.
2.
3.
4.
5.
6.
Follow cartridge replacement steps 1 through 5 above.
Remove retaining ring (K-44) with 3/8” hex key wrench.
Remove diverter (K-43) and o-ring (K-46).
Grease diverter o-ring and install into body.
Press diverter into o-ring and body.
Replace retaining ring.
Dimensions Origins Kitchen Faucet, S-23
10-1/8"
257mm
7-1/4"
184mm
5 1/4
133mm
6-1/4"
159mm
spacer
1/4-20" UNC
8-3/4"
222mm
10-7/8"
276mm
6"
152mm
1/2"- 13mm
with spacer
1-1/4"- 32mm
without spacer
optional 1/2-14
NPT fitting
7-1/2"
191mm
8"
203mm
Note: Dimensions subject to change without notice.
Parts Assembly Origins Kitchen Faucet, S-23 Series
K-41/42*
K-43
K-44
K-46
KN-1*
KN-2
KN-3RB*
KN-3BRB*
KN-4
KN-11 ASSY
Hand spray and holder
Diverter valve
Repair
Retainer ring
use only
O-ring
Valve cap
Compression ring
Solid Handle
Loop Handle
Cartridge
Supply body assembly
with diverter
KN-11A ASSY Supply body assembly
without diverter
KN-19A
Spacer
KN-20
O-ring (2)
KN-23
Anchor bar (2)
KN-26
Mounting spacer (2)
KN-30*
Escutcheon
KN-30A*
Escutcheon with hand spray hole
KN-33
Base plate
KN-118
Gasket
KN-157
Plug button
KN-169
Diverter assembly
KN-212
Screw (3)
L-22
Set screw
L-35
Carriage bolt (2)
L-36
Mounting nut (2)
LN-216*
Aerator (Faucet with hand spray)
LN-34
Cartridge wrench
LN-135
6” lever handle with
red/blue indicators
Aerator
(flow regulator)
Part Number*
Standard
Vandal Resistant
Aerator
with removal tool
2.2 gpm (8.3L/min) LN-15
1.5 gpm (5.7L/min) FLR-110-1.5
1.0 gpm (3.8L/min) FLR-110-1.0
.5 gpm (1.9L/min)
----
Figure 1
LN-135
KN-3BRB
6 inch lever handle
Loop handle
KN-3RB
L-22
Lever handle
KN-157
LN-34
KN-1
KN-2
KN-4
KN-20
KN-11 ASSY
KN-11A ASSY
LN-15
LN-216
LN-100
3/8"
K-44
K-43
K-46
KN-20
optional IPS
connections shown
Diverter assembly
KN-169
KN-19A
K-41/42
KN-30
KN-30A
L-35
KN-33
LN-101
FLR-110-1.5-VP
RL-288-VP-1.0
LN-100
KN-212
KN-118
KN-23
Removal tool part number, LL-60K
KN-26
L-36
* Note: When ordering parts for products with an
optional decorative finish, append appropriate three
letter finish suffix code to part numbers marked with
an asterisk (*).
For California Residents
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other
reproductive harm.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Website: symmons.com ■ Email: g e t h e l p @ s y m m ons.com
Copyright © 2017 Symmons Industries, Inc.
■
ZV-330 REV H
■
112017
Origins
®
Kitchen Faucet S-23-BH Series
Installation and Service Instructions
Installation
Caution: Be sure to turn off hot and cold water supplies before
installing or servicing faucet.
Step 1 If installing model with hose and spray, install hose
guide into hole in sink (normally the far right hole on four
hole sink). From underneath sink place washer then nut over
hose guide and secure to sink. Insert hose through hose guide
and up through middle hole from left in sink. Loosely install
the anchor bar (KN-23), spacer (KN-26) and nut (L-36) on the
mounting bolts and place gasket on base of faucet. From above
sink attach hose securely to nipple on base of faucet.
Step 2 Align faucet to sink by matching underside arrow
and word “FRONT” on base plate (KN-33) with front of sink.
Insert through center hole of sink and anchor bar/spacer/
nut assemblies through holes in sink. Secure faucet to sink by
tightening nuts from underside. (If sink surface is uneven use
putty or sealant to make proper seal under base.)
Step 3 Connect flex hoses (LN-247) to supply stops (left hose
to hot, right hose to cold). Hot supply hose is marked with tag.
Step 4 It is very important to thoroughly flush the supply
lines to prevent foreign matter, i.e. copper chips, sand, stones,
etc. from damaging the sealing surfaces of cartridge. Remove
aerator and turn valve handle on to full cold position, open cold
supply. Without closing, turn handle to full hot and open hot
supply. Let water run in hot only and cold only positions long
enough to flush supply lines thoroughly. If equipped with a hose
and spray, direct spray head into sink and activate spray. Shut
off faucet and replace aerator. Check for leaks.
Step 5 The handle limit stop can be set to limit handle turn
to the hot position. The limit mechanism is factory set to allow
full handle travel. To adjust the limit stop, turn handle to the
full hot position and lift handle to open faucet approximately
half way to obtain a smooth flow for correct initial temperature
measurement.
Step 6 If when faucet is on and in full hot position and water
is too hot, shut water off, remove plug button (KN-157), loosen
set screw (L-22) and remove handle (KN-3RB or KN-3BRB),
lift limit stop using a small flat head screw driver and rotate
clockwise to lower temperature. If water is not hot enough,
rotate counter clockwise (See Figure 1 on reverse side). After
correct temperature is achieved, reattach handle, reversing
procedure above.
holes or pliers on wrench and turn counter clockwise until
compression ring engages with cap (KN-1). Continue turning
counter clockwise so that cap/ring assembly is removed from the
body (KN-11).
Step 3 Remove cartridge and o-ring seal (KN-4).
Step 4 Install new cartridge while taking care to maintain
position of the o-ring seal at the base of the cartridge. Match
posts in base of cartridge with alignment holes in adapter plate
during assembly.
Step 5 Reassemble faucet in reverse fashion. Thread cap onto
body firmly by hand. Do not use a wrench which may damage
the finish. Tighten compression ring (KN-2) finger tight using
the wrench (LN-34) then 1/4 to 1/2 turn further. Set hot water
limit stop in accordance with installation step 6 above.
Diverter replacement (KN-169)
1.
2.
3.
4.
5.
6.
Follow cartridge replacement steps 1 through 5 above.
Remove retaining ring (K-44) with 3/8” hex key wrench.
Remove diverter (K-43) and o-ring (K-46).
Grease diverter o-ring and install into body.
Press diverter into o-ring and body.
Replace retaining ring.
Dimensions Origins Kitchen Faucet, S-23-BH
10 18 "
257mm
7 14"
184mm
5 14"
133mm
6 14"
159mm
spacer
1
4 "-20
UNC
20"
508mm
3
8 "-COMP
Cartridge Replacement (KN-4)
Step 1 Remove plug button (KN-157), loosen set screw (L-22)
and remove handle (KN-3RB or KN-3BRB).
Step 2 Engage tabs in cartridge wrench (LN-34) with slots
in compression ring (KN-2) and use screwdriver in wrench
8 34"
222mm
7
10 8"
276mm
1
2 "- 13mm
with spacer
114 "- 32mm
without spacer
8"
203mm
Note: Dimensions subject to change without notice.
Parts Assembly Origins Kitchen Faucet, S-23-BH Series
K-41/42*
K-43
K-44
K-46
KN-1*
KN-2
KN-3RB*
KN-3BRB*
KN-4
KN-11 ASSY
Hand spray and holder
Diverter valve
Repair
Retainer ring
use only
O-ring
Valve cap
Compression ring
Solid Handle
Loop Handle
Cartridge
Supply body assembly
with diverter
KN-11A ASSY Supply body assembly
without diverter
KN-19A
Spacer
KN-20
O-ring (2)
KN-23
Anchor bar (2)
KN-26
Mounting spacer (2)
KN-30*
Escutcheon
KN-30A*
Escutcheon with hand spray hole
KN-33
Base plate
KN-118
Gasket
KN-157
Plug button
KN-169
Diverter assembly
KN-212
Screw (3)
L-22
Set screw
L-35
Carriage bolt (2)
L-36
Mounting nut (2)
LN-216*
Aerator (Faucet with hand spray)
LN-34
Cartridge wrench
LN-135
6” lever handle with
red/blue indicators
LN-247
Flex hoses (3/8 inch compression)
Aerator
(flow regulator)
Figure 1
LN-135
KN-3BRB
L-22
Lever handle
KN-157
LN-34
KN-1
KN-2
KN-4
KN-20
KN-11 ASSY
KN-11A ASSY
LN-15
LN-216
LN-100
3/8"
K-44
K-43
K-46
KN-20
LN-247
Diverter assembly
KN-169
KN-19A
K-41/42
KN-30
KN-30A
L-35
KN-33
KN-212
LN-101
FLR-110-1.5-VP
RL-288-VP-1.0
LN-100
KN-118
KN-23
KN-26
Removal tool part number, LL-60K
L-36
* Note: When ordering parts for products with an
optional decorative finish, append appropriate three
letter finish suffix code to part numbers marked with
an asterisk (*).
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Website: symmons.com ■ Email: g e t h e l p @ s y m m ons.com
Copyright © 2017 Symmons Industries, Inc.
Loop handle
KN-3RB
Part Number*
Standard
Vandal Resistant
Aerator
with removal tool
2.2 gpm (8.3L/min) LN-15
1.5 gpm (5.7L/min) FLR-110-1.5
1.0 gpm (3.8L/min) FLR-110-1.0
.5 gpm (1.9L/min)
----
6 inch lever handle
■
ZV-330 REV H
■