AutroFlame X22AF Ultraviolet Flame Detector

AutroFlame X22AF
Ultraviolet Flame Detector
Product datasheet
Features
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
FM 3260 (2000).
EM 54-10 Certified (VdS).
ATEX Directive compliant.
Advanced signal processing.
Arc — unequaled false alarm rejection.
HART models available.
Responds to a fire in the presence of modulated
blackbody radiation (i.e. heaters, ovens, turbines)
without false alarm.
High speed capability.
Automatic, manual or magnetic optical integrity
(oi) testing — no external test lamp required.
Easily replaceable oi plate.
Fire, fault and auxiliary relays standard.
MODBUS RS-485 communication.
4 to 20 mA isolated output (optional).
Pulse output for compatibility with controller based
systems (optional).
A tricolor LED on the detector faceplate indicates
normal condition and notifies personnel of fire
alarm or fault conditions.
Mounting swivel allows easy sighting.
Integral wiring compartment for ease of
installation.
Class A wiring per NFPA-72.
Meets NFPA-33 response requirement for under
0.5 second (available when model selected).
RFI and EMC Directive compliant.
Built-in data logging / event monitoring.
Application/Description
The evolution continues with the new AutroFlame
X22AF UV Flame Detector. The X22AF is the
most advanced UV detector meeting standards
and approvals worldwide, combined with a superior
mechanical design. The detector is equipped with
automatic, manual and magnetic oi test capability.
The detector has Division and Zone explosion-proof
ratings and is suitable for use in a variety of
applications.
116-P-X22AF/CGB, 2013-10-10
The standard output configuration includes fire, fault and
auxiliary relays. An optional 4 to 20 mA output with HART
can be provided in addition to the three relays. A tricolor
LED on the detector faceplate indicates normal condition
and notifies personnel of fire alarm or fault conditions.
The X22AF housing is available in aluminum or stainless
steel, with NEMA 4X and IP66 rating.
Typical applications include:
nn Hydrogen storage
nn Munitions
nn Silane storage.
Protecting life, environment and property

AutroFlame X22AF Ultraviolet Flame Detector
Specifications
Input Voltage
24 Vdc nominal. Operating range is 18 to 30 Vdc.
Power Consumption
2.5 watts @ 24 Vdc nominal.
7.6 watts @ 30 Vdc with EOL resistor installed.
Relays
Contacts rated 5 amperes at 30 Vdc.
Fire Alarm:
— Form C (NO and NC contacts)
— normally de-energized
— latching/non-latching.
Fault:
Auxiliary:
— Form A (NO contacts)
— normally energized
— latching/non-latching.
— Form C (NO and NC contacts)
— normally energized
— latching/non-latching.
Current Output (opt.)
0–20 mA, with a maximum loop resistance of 500
ohms from 18–19.9 Vdc, 600 ohms from 20–30 Vdc.
Temperature Range
Operating: –40°F to +167°F (–40°C to +75°C).
Storage: –67°F to +185°F (–55°C to +85°C).
Humidity Range
0 to 95% relative humidity, can withstand 100%
condensing humidity for short periods of time.
Field of View
The X22AF has a 90 degree cone of vision with the
highest sensitivity lying along its central axis.
Warranty
3 years
Enclosure Material
Copper-free aluminum or 316 stainless steel
Conduit Entry Size
3/4 inch NPT or 25 mm.
Shipping Weight
Aluminum:
6 pounds (2.75 kg).
Stainless Steel: 10 pounds (4.5 kg).
Part Numbers
Please contact the sales department or refer to the
product catalogue.
Certification
¨
Class I, Div. 1, Groups B, C & D (T5);
Class II, Div. 1, Groups E, F, & G (T5);
Class I, Div. 2, Groups A, B, C & D (T3);
Class II, Div. 2, Groups F & G (T3);
Class III.
Enclosure NEMA/Type 4X.
IECEx Certificate of Conformity
IECEx ULD 06.0018X
Ex d e IIC T5-T6 Gb
T6 (Tamb = –50°C to +60°C).
T5 (Tamb = –50°C to +75°C).
IP66
– or –
Increased Safety Model
0539
II 2 G
Ex d e IIC T5–T6 Gb
DEMKO 02 ATEX 132195X
T6 (Tamb = –50°C to +60°C).
T5 (Tamb = –50°C to +75°C).
IP66
Flameproof Model
0539
II 2 G
Ex d IIC T5–T6 Gb
DEMKO 02 ATEX 132195X
T6 (Tamb = –55°C to +60°C).
T5 (Tamb = –55°C to +75°C).
IP66
Ex d IIC T5-T6 Gb
T6 (Tamb = –55°C to +60°C).
T5 (Tamb = –55°C to +75°C).
IP66.
Dimensions
Dimensions shown in inches (centimeters)
4.7
(11.9)
Response Characteristics
10.2
(25.9)
B2223
Wiring
14 AWG (2.08 mm2) or 16 AWG (1.31 mm2)
shielded cable is recommended.
Very High Sensitivity
Fuel
Size
Distance
Feet (m)
Typical Response
Time (seconds)
Mode
n-Heptane
1 x 1 foot
85 (25.9)
3
Low Arc
Methane
32 inch plume
100 (30.5)
2
Low Arc
NOTE: Refer to the X22AF instruction manual x22af_igb for details regarding
detector response.
4.8
(12.2)
9
4-20 mA +
19
4-20 mA –
SPARE
29
8
4-20 mA + REF
18
4-20 mA – REF SPARE
28
7
COM FIRE
17
COM FIRE
COM AUX
27
6
N.O. FIRE
16
N.O. FIRE
N.O. AUX
26
5
N.C. FIRE
15
N.C. FIRE
N.C. AUX
25
4
COM FAULT
14
COM FAULT
RS-485 A
24
3
N.O. FAULT
13
N.O. FAULT
RS-485 B
23
2
24 VDC +
12
24 VDC +
MAN Oi
22
1
24 VDC –
11
24 VDC –
24 VDC –
21
B2061
Wiring Terminal Identification for X22AF
Autronica Fire and Security AS | Tel.: +47 73 58 25 00 | E-mail: info@autronicafire.no | www.autronicafire.com | Page 2