dual technology dual relay wall switch occupancy sensor

WATTSTOPPER®
SENSORS OCCUPANCY & VACANCY
DUAL TECHNOLOGY DUAL RELAY
WALL SWITCH OCCUPANCY SENSOR
High sensitivity and dense coverage
for exceptional performance
Two relays for control of two separate
lighting loads or circuits
Allows multi-way control from one of
up to four control locations
DSW-302
Optional neutral connection with break
off tab to expose neutral terminals
120/277 VAC and 347 VAC models
Defaults to Auto-ON to 50% operation
for maximum energy savings
Color-matched lens and low
profile for appealing design
Description
Optional Neutral Connection
­­­­­­­­ he DSW-302 dual technology wall switch sensor turns lights
T
ON and OFF based on occupancy and contains two relays
for controlling two independent lighting loads or circuits. It
combines the benefits of passive infrared (PIR) and ultrasonic
detection technologies for high sensitivity to small and large
movements. The DSW-302 replaces existing wall switches and
fits a standard decorator wall plate.
The DSW-302 sensor uses a patent pending Neutral Sense
Technology. Any DSW-302 sensor can be used for a two-wire
or three wire application, either to work with existing wiring, or
to meet local or national code requirements. An easy-to-break
plastic tab covers neutral screw terminals. Once the sensor
is connected to neutral it complies with all codes that restrict
current leakage to ground.
Operation
Applications
Each of the DSW-302’s relays can control a separate lighting
load. By default, when the PIR sensor detects occupancy, relay
1 turns ON automatically. Remaining lighting must be turned
on manually. Detection by either PIR or ultrasonic technology
holds lights ON. When occupancy is no longer detected and the
time delay elapses, lights automatically turn OFF. Dual ON/
OFF buttons allow the user to turn on and off each of the loads
manually. DIP switch settings allow for a variety of control
options such as Auto-ON or Manual-ON for each relay, walkthrough, and test mode. Multiple sensors may be used for
control of one or more loads from up to four locations.
The DSW-302 sensor is great for retrofit projects and has the
flexibility for applications where one technology alone may not
be sufficient. In addition, its dual relays allow bi-level switching
or control of two loads. Applications include small and executive
offices, small and medium conference rooms and lunch/break
rooms. This sensor is also a perfect choice for ADA-compliant
buildings due to lower mounting height requirements.
Features
• Complies with 2011 NEC requirements
• Zero-crossing on both relays for long relay life
• Vandal resistant lens combines precise coverage with
durability
• Selectable walk-through mode turns lights off three minutes
after the room is initially occupied if no motion is detected
after the first 30 seconds
• Selectable audible alert for impending shutoff
• In automatic mode, sensor returns automatically to Auto-ON
after lights are turned off manually; ideal for presentations
WWW.LEGRAND.US/WATTSTOPPER
• Test mode allows quick and easy adjustments
• Four occupancy logic options to customize control to meet
application needs
• Optional light level sensor holds secondary lights off when
ambient lighting is above the preset level
• Service mode allows sensor to operate as a service switch in
the unlikely event of a failure
• Sensor coverage tested to NEMA Guide Publication WD 7-2000
Specifications
• DSW-302: 120/277VAC; 50/60Hz, 1/6 hp
@ 120VAC, 0-800W ballast, LED, and tungsten
@ 277VAC, 0-1000W ballast and LED
• DSW-302-347: 347VAC; 50/60Hz, 1/6 hp; 0-1200W ballast
and LED
• Time delays: 5, 15 or 30 minutes), walk-through, testmode/20 minutes
Controls & Settings
DIP Switch Settings
Time Delay
TRIGGER
Test/20 min
5 minutes
15 minutes
30 minutes
DIP Switches
ALERTS
RLY 1 MAN
RLY 2 MAN
DELAY
WALK
PIR 50%
Ultrasonic Sensitivity
Adjustment Trimpot
Ultrasonic Cones
Detection LEDs
Red = PIR
Green = Ultrasonic
Walk-Through
8" flying leads for line,
load, ground and
multi-way
connections
PIR Lens
Enabled
Disabled
PIR Sensitivity
Low, 50%
High
Simple optional neutral connection
allows installation in any 2-wire or
3-wire application.
1 2
Time
Delay
On Mode
Relay 1
Relay 2
Trigger
Mode
ON
1
2
3
4
5
6
7
8
3
Trigger
Mode
Standard
Option A
Option B
Option C
4
7
Relay 1 On Mode
8
Enabled
Disabled
Both
Either Either (5)
PIR
Either Either (5)
PIR
PIR
PIR (5)
Both
Both
Both (5)
Manual On
Auto On
DSW-302 ONLY
5 6
Relay 2 On Mode
Manual On
Auto On
1
2
9
Factory Settings:
All models
1 DSW-301
2 DSW-302
=ON =OFF
Breakaway
tab
Audible Alert
9
Walk-Through
Audible Alerts
PIR Sensitivity
Re-trigger
(seconds
duration)
ON/OFF Buttons
Relay 1
Relay 2
Initial
Occupancy
Maintain
Occupancy
Product Controls & Neutral Option
• Sensitivity adjustment: PIR (high/low), Ultrasonic
(fully variable)
• Coverage: M
ajor motion, PIR 35’ x 30’, Ultrasonic 20’ x 20’
Minor motion, PIR 20’ x 15’, Ultrasonic 15’ x 15’
• Dimensions (L x W x D): 2.73” x 1.75” x 1.81”
(69mm x 44mm x 46mm)
• UL and cUL listed
• Five year warranty
Optional neutral
terminals behind
breakaway tab
Coverage & Wiring
Coverage Pattern
Wiring Diagrams
For best performance,
Wattstopper recommends
using this sensor in spaces
no larger than 18’ x 15’.
Bi-level and
multi-way wiring
Major motion
Major motion
Minor motion
Minor motion
PIR
Coverage
Line
Ultrasonic
Coverage
35’
(10.6m)
Black
Red
Blue
Yellow
Black
Red
Blue
Green
Brown
Green
Green
Neutral
(optional)
Green
Ground
Brown
Primary
Load
Secondary
Load
Neutral
(optional)
Ground
Neutral
13’
(4.0m)
10’
(3.0m)
20’
(6.1m)
Two circuit and
multi-way wiring
Neutral
Line 1
Line 2
15’
(4.5m)
7.5’
(2.2m)
Black
Blue
7.5’
(2.2m)
10'
(3.0m)
Green
4’
(1.2m)
Green
0
Ordering Information
Catalog #
13’
(4.0m)
35’
(10.6m)
Ground
Red
Yellow
Black
Blue
Brown
Green
Neutral
(optional)
Green
Red
Brown
Primary
Load
Secondary
Load
Neutral
(optional)
Ground
Neutral
Color
Voltage
Load Rating
DSW-302-W
White
@ 120VAC, 0-800W ballast, LED, tungsten, 1/6 hp
DSW-302-LA
Lt. Almond
DSW-302-I
Ivory
120VAC; 50/60Hz
or
277VAC; 50/60Hz
DSW-302-G
Grey
DSW-302-B
Black
DSW-302-R
Red
DSW-302-347-W
White
347VAC; 50/60Hz
0-1200W ballast & LED, 1/6 hp
DSW-302-347-LA
Lt. Almond
DSW-302-347-I
Ivory
DSW-302-347-G
Grey
DSW-302-347-B
Black
DSW-302-347-R
Red
or
@ 277VAC 0-1000W ballast, LED, 1/6 hp
Order wall plate separately.