Dometic Turbo (DTU/DTM), Vector Compact (DCU), EnviroCool (EDC), Low Profile (DLU) Installation manual


Add to my manuals
12 Pages

advertisement

Dometic Turbo (DTU/DTM), Vector Compact (DCU), EnviroCool (EDC), Low Profile (DLU) Installation manual | Manualzz
Self-contained Air Conditioning Systems
Installation Manual For These Product Families:
Turbo
(DTU/DTM)
Vector Compact
(DCU)
EnviroCool
(ECD)
Low Profile
(DLU)
Dometic
Rev. 20170
L-4111 English
P/N 339708
COPYRIGHT © 2011-2016 Dometic Corporation. All Rights Reserved.
No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical,
photocopying, recording or otherwise without prior written consent by Dometic Corporation. Every precaution has been taken in the preparation of this
manual to insure its accuracy. However, Dometic Corporation assumes no responsibility for errors and omission. Neither is any liability assumed for
damages resulting from the use of this product and information contained.
INTRODUCTION
Improper installation procedures can result in unsatisfactory performance and/or premature failure of these air conditioning (A/C)
units. In the interest of product improvement, Dometic’s specifications and design are subject to change without prior notice.
This installation can typically be done by one person with brief help from an additional person.
INSTALLATION
SAFETY CONSIDERATIONS
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Indicates a situation which can cause damage to the engine, personal property and/or the environment, or
cause the equipment to operate improperly.
L-4111 ENGLISH
1
CARBON MONOXIDE HAZARD. Never install your air conditioner in the bilge or engine room areas. Ensure
that the selected location is sealed from direct access to bilge and/or engine room vapors. Do not terminate condensate drain
line within 3' (0.91 m) of any outlet of engine or generator exhaust systems, nor in a compartment housing an engine or
generator, nor in a bilge, unless the drain is connected properly to a sealed condensate or shower sump pump. If drain line is
not properly installed, then dangerous fumes may travel up drain line and contaminate living quarters. Failure to follow this
precaution could result in death or serious injury.
CARBON MONOXIDE HAZARD. Never install the A/C unit in a location where it can circulate carbon
monoxide, fuel vapors or other noxious fumes into the boat's living spaces. Do not install or operate a self-contained unit in the
engine room or near an internal combustion engine. Failure to follow this precaution could result in death or serious injury.
EXPLOSION HAZARD. Never install the A/C unit in a location containing gasoline engines, tanks, LPG/
CPG cylinders, regulators, valves or fuel line fittings. Unless labeled otherwise, self-contained units do not meet federal
requirements for ignition protection. Failure to follow this precaution could result in death or serious injury.
ELECTRICAL SHOCK HAZARD. Be sure to effectively ground the A/C unit. The A/C unit must be effectively
grounded to minimize electrical shock hazard. Refer to the installation guidelines for further information. Failure to follow this
precaution could result in death or serious injury.
Contains fluorinated greenhouse gases in hermetically sealed equipment. Refer to the condensing unit's
product data plate label for quantity of refrigerant shown in weight and GWP. Refrigerant added should be noted on unit label.
PRIOR TO INSTALLATION
Read these instructions completely and then plan all connections which must be made to the A/C unit including ducting,
condensate drain line, seawater inlet and outlet hoses, electrical power connection, location of control, and seawater pump
placement, to assure easy access for routing and future servicing.
INSTALLATION OVERVIEW
See Figure 1 for an overview of a typical self-contained A/C system installation.
Figure 1: Installation Overview
2
L-4111 ENGLISH
Self-contained Air Conditioning Systems Installation Manual
BLOWER ROTATION (IF APPLICABLE)
Rotate the blower to the direction which allows the most direct airflow discharge through the ducting.
•
For Turbo blowers – Loosen the adjustment screw on blower mount ring, rotate blower to desired position, and then
tighten adjustment screw. See Figure 2.
•
For EnviroCool/MCS/ECD blowers – Remove screws on plate, rotate blower to vertical or horizontal position, and
fasten plate using self-tapping screws. See Figure 2.
•
For Vector Compact blowers – Remove mounting-ring screws and screws that attach the blower to the drain pan.
Rotate the blower to the desired position, and then install self-tapping mounting screws. Plug any unused screw holes
in the blower to prevent air loss. See Figure 2.
PLACEMENT OF A/C UNIT
IMPORTANT INSTALLATION NOTE: The turbo self-contained condensate base pan is equipped with vibration isolators
installed in the bottom of the pan. These isolators are designed to dampen the vibration caused by the operating A/C unit from
transferring into the mounted surface. Care must be taken when moving the A/C unit across mounting surfaces as isolators can
be damaged.
Isolators will not normally pull out of pan, but can turn sideways if dragged and may break if excessive
dragging occurs. Unit must be picked up after moving to allow isolator to reset into well or vibration isolation will be ineffective.
The A/C unit must be mounted to a low flat level surface, in bottom of locker, under a bunk or dinette seat, or in a similar
location. See Figure 1 before mounting unit.
CARBON MONOXIDE HAZARD. Never install the A/C unit in the bilge or engine room areas. Read the
safety considerations on page 2 and see Figure 1 before mounting unit.
Figure 2: Blower Rotation Procedures for Each System Type
EnviroCool/MCS/ECD Systems
Remove 7 screws to
rotate blower
Standard
blower position
as shipped
1. Remove screws on plate.
2. Rotate blower to horizontal or vertical position.
3. Fasten blower in place using self-tapping screws.
L-4111 ENGLISH
3
Vector Compact Systems
Standard blower
position as shipped
Screws on
blower ring
Screws on drain
pan or bracket
1. Remove screws from blower
ring.
2. Remove screws attaching
blower to drain pan or
bracket (27k).
3. Rotate blower to desired
position.
4. Fasten blower in place using
self-tapping screws.
5. Plug any unused holes to
prevent air loss.
Figure 3: Placement Relating to Airflow
4
L-4111 ENGLISH
Self-contained Air Conditioning Systems Installation Manual
MOUNTING BRACKETS AND CONDENSATE DRAIN
Figure 4: Mounting Brackets and Condensate Drains
Figure 5: Mounting Brackets and Condensate Drains on Other Self-Contained Systems
PVC fitting
(1/2”HB x 12MPT)
Solid washer
Base pan
Liquid-seal washer
Mounting bracket
Base pan
Locking nut
CARBON MONOXIDE HAZARD. Verify the condensate drain line is properly installed and sealed. Do not
terminate condensate drain line within 3' (0.91 m) of any outlet of engine or generator exhaust systems, nor in a compartment
housing an engine or generator, nor in a bilge, unless the drain is connected properly to a sealed condensate or shower sump
pump. If drain line is not properly installed, then dangerous fumes may travel up drain line and contaminate living quarters.
AIR FILTERS
Air filters remove airborne particulates from the cabin air and keep the evaporator coil clean. One, and only one, air filter must
be installed for each air conditioner unit – either on the A/C unit or in the return air (RA) grille.
Clean the air filter regularly per instructions in Owner’s Control Manual to ensure proper operation.
L-4111 ENGLISH
5
GRILLES AND TRANSITION BOXES
Install the supply air grille as high as possible in a location that will provide uniform air distribution throughout the cabin; grille
louvers should be directed upward. The return air grille should be installed as low and close to the A/C unit as possible to insure
direct uninterrupted airflow to the evaporator.
To ensure proper airflow, the return air grille should have a minimum 4" (101.6 mm) of air circulation
clearance in front of it, free from any furniture or other obstructions. See Figure 3.
In no instance should a supply air discharge be directed towards a return air grille, as this will cause the system to short cycle.
Allow for adequate clearance behind the supply air grille(s) for the transition box and ducting connection. See Table 1 for
minimum grille sizes.
DUCTING
Good airflow is critical for the performance of the entire system. It is highly dependent on the quality of the ducting installation.
The ducting should be run as straight, smooth and taut as possible minimizing the number of 90° bends (two 90° bends can
reduce airflow by 25%). Table 1 shows minimum duct diameters and their corresponding supply and return air grille minimum
areas in square inches. If a transition box is used, the total area of supply air ducts going out of the box should at least equal the
area of the supply duct going into the box.
Table 1: Minimum Duct and Grille Sizes per BTU Capacity
3.5K
BTU
6K
BTU
8K
BTU
10K
BTU
12K
BTU
16K
BTU
18K
BTU
27K
BTU
3/76
4/102
5/127
6/152
6/152
7/178
7/178
8/203
Minimum Duct Area
(sq in/cm)
6.8/44
12.6/81
19.6/126
28.3/183
28.3/183
38.5/248
38.5/248
50.3/325
Minimum Return Air Grille
(sq in/cm)
64/413
64/413
80/516
100/645
130/839
160/1032
200/1290
240/1548
Minimum Supply Air Grille
(sq in/cm)
12/77
32/206
48/310
60/387
70/452
80/516
100/645
140/903
Minimum Duct Diameter
(in/mm)
Figure 6: Proper Ducting Connections
All ducting should:
6
•
Be appropriately sized for each application.
•
Run as smoothly and taut as possible.
•
Have as few bends or loops as possible.
•
Be securely fastened to prevent sagging during boat
operation.
•
Have all excess ducting lengths trimmed off.
•
Not be flattened or kinked.
L-4111 ENGLISH
Self-contained Air Conditioning Systems Installation Manual
•
Insulated when located in high heat load areas (hull side, mechanical compartments, etc.).
•
Be properly protected against potential damage when routed through open areas.
•
Not be routed through engine room or any area where it may be exposed to dangerous vapors or exhaust fumes.
SEAWATER SYSTEM
1.
Install the seawater scoop thru-hull inlet as close to the keel and as far below the water line as possible, facing forward.
Bed the scoop with a marine sealant designed for underwater use.
2.
Install a bronze, full flow seacock on the seawater scoop thru-hull inlet.
3.
Install a seawater strainer below the level of the pump with access to filter.
4.
Mount the pump above the strainer and at least one foot below the waterline.
5.
Connect the seacock and strainer with an uphill run of reinforced marine grade hose.
6.
Connect the discharge from the pump uphill to the bottom inlet of the A/C unit’s condenser coil with 5/8" (15.9 mm)
reinforced marine grade hose. Connect the discharge from the condenser coil to the overboard discharge thru-hull
fitting with 5/8" (15.9 mm) reinforced marine grade hose.
7.
Avoid loops, high spots or the use of 90° elbows with seawater hose. Each 90° elbow is equivalent to 2.5' (0.762 m) of
hose and a 90° elbow on the pump outlet is equivalent to 20' (61 m) of hose.
8.
Double clamp all hose connections with two stainless steel clamps, reversing the clamps.
9.
Use threaded seal tape on all threaded connections.
10. Connect all metallic parts in contact with seawater to the vessel’s bonding system including the speed scoop inlet,
strainer, pump and the air conditioner.
Failure to follow the above procedure will void warranty.
Figure 7: Seawater System
CORRECT
STEADY UPWARD FLOW FROM INLET TO
UNIT THEN DOWNWARD TO OUTLET,
HOSES DOUBLE CLAMPED (SEE NOTES)
CORRECT
• STRAINER MUST BE BELOW PUMP, HOSES MUST BE
DOUBLE CLAMPED
• HOSES MUST NOT HAVE KINKS, LOOPS OR HIGH SPOTS
WHERE AIR CAN BE TRAPPED
• PUMP & STRAINER MUST BE BELOW WATER LINE
NOTES:
1) THRU HULL INLET, BALL VALVE, HOSE AND STRAINER SHOULD BE SIZED NO SMALLER THAN PUMP INLET.
2) INSTALL THRU HULL FITTING AS FAR BELOW THE WATER LINE AS POSSIBLE.
3) PUMP NEEDS DEDICATED THRU HULL NOT SHARED WITH OTHER PUMPS.
4) AVOID OR MINIMIZE 90° ELBOW FITTINGS AS MUCH AS POSSIBLE, ROTATE PUMP HEAD TOWARDS DIRECTION OF WATER FLOW.
L-4111 ENGLISH
7
ELECTRICAL CONNECTIONS, GROUNDING AND BONDING
All A/C units have a terminal strip mounted inside the electric box. The terminal strip is labeled for proper connections of the
electrical supply, ground wires and pump circuits. A wiring diagram is provided in the electrical box. The wiring diagram in the
electrical box supersedes ABYC standards. The correct size circuit breaker should be used to protect the system as specified
on the A/C unit’s data plate label. A minimum of 12 AWG boat cable should be used to supply power to the A/C unit and the
seawater pump. All connections shall be made with ring or captive fork terminals.
ELECTRICAL SHOCK HAZARD. Always turn off the A/C power supply breaker before opening the electrical
box. All A/C units have a terminal strip mounted inside the electric box. The terminal strip is labeled for proper connections of
the electrical supply, ground wires and pump circuits. A wiring diagram is provided in the electrical box. The wiring diagram in
the electrical box supersedes ABYC standards. The correct size circuit breaker should be used to protect the system as
specified on the A/C unit's data plate label. A minimum of 12 AWG boat cable should be used to supply power to the A/C unit
and the seawater pump. All connections shall be made with ring or captive fork terminals.
Each A/C unit installed requires its own dedicated circuit breaker. If there is only one A/C unit installed, the seawater pump does
not require a circuit breaker; the wiring from the seawater pump is connected to the terminal strip in the electric box. If two or
more A/C units use the same seawater pump, the pump wires will be connected to a pump relay panel (PRP) which in turn has
its own dedicated circuit breaker sized for the pump (20 amp max). Please see the wiring diagram furnished with the PRP
(NOTE: PRP triac must have its mounting screw installed in order to dissipate heat). Electrical connections in the bilge and/or
below the waterline should use heat shrink type butt splices.
Field wiring must comply with ABYC electrical codes. Power to the unit must be within the operating voltage range indicated on
the data plate. Properly sized fuses or HACR circuit breakers must be installed for branch circuit protection. See data plate for
maximum fuse/circuit breaker size (mfs) and minimum circuit ampacity (mca).
ELECTRICAL SHOCK HAZARD. The A/C unit must be effectively grounded to minimize electrical shock.
Field wiring must comply with ABYC electrical codes. Power to the unit must be within the operating voltage range indicated on
the data plate. Properly sized fuses or HACR circuit breakers must be installed for branch circuit protection. See data plate for
maximum fuse/circuit breaker size (mfs) and minimum circuit ampacity (mca).
The following are to be observed:
1.
Alternating Current (AC) grounding (green wire) must be provided with the AC power conductors and connected to the
ground terminal (marked “GRND”) at the AC power input terminal block of the unit(s), per ABYC standard E-8, or
equivalent.
2.
Connections between the vessel’s AC system grounding conductor (green wire) and the vessel’s Direct Current (DC)
negative or bonding system should be made as part of the vessel’s wiring, per ABYC standard E-9, or equivalent.
3.
When servicing or replacing existing equipment that contains a chassis-mounted ground stud, the service person or
installer must check the vessel’s wiring for the existence of the connection required in item 2 above.
ABYC standards are available from:
American Boat and Yacht Council
613 Third Street, Suite 10
Annapolis, MD 21403
Phone: (410) 990-4460
Fax: (410) 990-4466
The air conditioning unit must be connected to the boat’s bonding system to prevent corrosion due to stray electrical current.
Ensure that the AC ground of the air conditioning unit is properly connected to the AC ground of the boat. Within the boat itself,
ensure that the AC ground bus is connected to the DC ground bus at exactly one place (no more, no less). All pumps, metallic
valves and fittings in the seawater circuit that are isolated from the air conditioning unit by PVC or rubber hoses must be
individually bonded to the boat’s bonding system also. This will help eliminate any possibility of corrosion due to stray electrical
current.
FAILURE TO PROPERLY GROUND AND BOND THE SYSTEM WILL VOID WARRANTY!
8
L-4111 ENGLISH
Self-contained Air Conditioning Systems Installation Manual
OWNER’S LIMITED WARRANTY
As hereinafter described, Dometic limits the duration of any implied warranty to the duration of the underlying express
warranty and also disclaims any liability for consequential or incidental damages arising from any application,
installation, use or malfunction of any warranted product.
SECTION I - WHAT’S COVERED
What does the Limited Warranty cover?
Products manufactured by Dometic Corporation (Dometic) are under limited warranty to be free from defects in workmanship or
materials at the time of sale. This being under normal use and service, with the obligation of Dometic under this limited warranty,
being limited to replacing or repairing – at Dometic’s sole choice – any component(s) which shall disclose defects within the
limits defined in Section III which upon examination by Dometic, shall appear to the satisfaction of Dometic to be defective or
not up to specifications.
This Limited Warranty is made in lieu of all other express warranties, obligations, or liabilities on the part of Dometic. In
those instances in which a cash refund of original purchase price is made, such refund shall effect the cancellation of the
contract of sale without reservation of rights on the part of the purchaser. Such refund shall constitute full and final
satisfaction of all claims which the purchaser has or may have against Dometic due to any actual or alleged breach of
warranty, either express or implied, including, without limitation, any implied warranty of merchantability or fitness for
a particular purpose. The remedies described above are your sole and exclusive remedies and Dometic’s entire liability for
any breach of this limited warranty. Dometic’s liability shall under no circumstances exceed the actual amount paid by you for
the defective product, nor shall Dometic under any circumstances be liable for any consequential, incidental, special or punitive
damages or losses, whether direct or indirect. Some states do not allow the exclusion or limitation of incidental or consequential
damages so the above limitation may not apply to you.
The Dealer is not an agent for Dometic, except for the purpose of administering the above warranty to the extent herein
provided. Dometic does not authorize the dealer or any other person to assume for Dometic any liability in connection
with such warranty, or any liability or expense incurred in the replacement or repair of its products other than those
expressly authorized herein. Dometic shall not be responsible for any liability or expense except as is specifically
authorized and provided in this section.
Dometic reserves the right to improve its products, through changes in design or material without being obligated to incorporate
such changes in products of prior manufacture. Dometic can make changes at any time in design, materials, or part of units of
any one, model year, without obligation or liability to owners of units of the same year's model of prior manufacture.
This warranty gives you; the purchaser, specific legal rights, and you may also have other rights which vary from state to state.
You also have implied warranty rights, including an implied warranty of merchantability, which means that your product must be
fit for the ordinary purposes for which such goods are used. The duration of any implied warranty rights is limited to the
duration of the express warranty as found in Section III. Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you.
SECTION II - WHAT’S NOT COVERED
What does this Limited Warranty not cover?
This Warranty Shall Not Apply to:
1.
Failures resulting from improper installation or use contrary to instructions.
2.
Failures resulting from abuse, misuse, accident, fire, or submergence.
3.
Any part manufactured by Dometic, which shall have been altered so as to impair its original characteristics.
4.
Any parts which fail as a result of misuse, improper application or improper installation.
5.
Items not manufactured by Dometic, i.e., items, which are purchased from another manufacturer and supplied as
received by Dometic without alteration or modification except as any part of a Dometic manufactured unit or
component.
6.
Components or parts used by or applied by the purchaser, as an integral part of products not manufactured by
Dometic.
7.
Labor resulting from difficult access to a Dometic product. The original installer or OEM is responsible for accessibility
of unit.
8.
Leaks due to improper installation of split systems and refrigeration systems, for example; packing glands, flare nuts,
quick disconnects. The adjustment of the refrigerant charge on a split system should be charged to the original installer
or OEM.
9.
Freight Damage.
10. Pumps that have been run dry, are water damaged or have blown freeze plugs.
L-4111 ENGLISH
9
11. Pumps with cracked heads.
12. Pump seals are not covered.
13. UV light bulbs are not covered.
14. Liquid line filter dryers are not covered.
15. Blowers with water damage.
16. Logic boards with water damage.
17. Logic boards with blown MOV's (Power Surge)
18. Mis-programmed displays.
19. Display heads with water damage.
20. Dirty Condensers and/or Evaporators.
21. Failures due to improper winterization.
22. Unit damage as a result of improper return packaging.
23. Replacement of freon with substitute without authorization from factory.
24. Environmental and/or Recovery Fees.
25. Welding and Nitrogen Fees.
26. Travel costs are included in the hourly labor allowances and should not be billed as a separate item without
preapproval form the factory.
Installation and application of Dometic components is not warranted by Dometic, because Dometic has no control or
authority over the selection, location, application, or installation of these components.
SECTION III - COVERAGE PERIOD
What is the period of coverage?
(See the Table of Warranty Periods.)
All Dometic components bear a data plate on which there are model and serial numbers. The serial number is date coded. To
determine whether or not any Dometic component is in warranty, proceed as follows:
1.
Determine the manufacture date of the component from the serial number on the data plate. If you are not familiar with
the date code, write or call the Dometic Customer Service Department to obtain the manufacture date. The hours of
the Customer Service Department are 8:00 a.m. - 5:00 p.m. (USA, Eastern Standard Time Zone) Monday through
Friday excluding holidays.
2.
It is possible that there might exist a considerable time lag between the date a component is manufactured and the
date it is put in service. In such instances, the date of manufacture could indicate that the item is out of warranty.
However, based on the date the equipment is first put in service, the item may still be covered by the Dometic warranty
as described in Section I. For proof of date put in service, Dometic will require a copy of the bill of sale of the Dometic
equipment from the installer or new boat dealer to the original owner.
SECTION IV - GETTING SERVICE
How do you get service?
Please read the following Warranty Procedure:
If the failure of a Dometic component is determined by Dometic to be covered under the Dometic warranty and the time in
service is determined to be within the warranty time limit, the owner has the following three options:
10
1.
Preferred option: Have a Dometic authorized Servicing Dealer, perform the work needed. The customer needs to call
Dometic Customer Service Department for a recommendation as to the closest dealer. If the customer already knows
an authorized servicing dealer, the dealer should be contacted directly.
2.
Second option: If the customer contacts Dometic Service Department for a Servicing Dealer and Dometic has no one
in that particular area, Dometic will authorize the use of a local service company and Dometic will work with the local
company to assist in any way possible.
3.
Third option: The customer may send his equipment back to the factory to have the repair work done. Dometic will
make every effort to return the equipment to the customer within a three week time period. If the claim represents a
legitimate warranty problem, Dometic will pay the freight both ways. Dometic prefers option one first, option two
second, and option three only if one and two are not available.
L-4111 ENGLISH
Self-contained Air Conditioning Systems Installation Manual
The customer may contact the Dometic Service Department at (954) 973-2477 Monday through Friday, 8:00am - 5:00pm
Eastern Time. After hours (evenings and weekends) technical support is offered through Dometic's 24/7 Hotline at (888) 4404494.
TABLE OF WARRANTY PERIODS
DOMETIC SELF-CONTAINED AIR CONDITIONING
Important Notes:
1. Warranty periods begin from the date of possession of the boat by the first owner if OEM installed or date of installation if dealer
installed, but not to exceed three (3) years from date of production. The warranty is transferable and will carry the remainder of the
original owner's warranty based on the original date of purchase or date of installation.
2. Proof of purchase or installation may be required to verify warranty coverage.
3. Any unit or replacement part installed due to a warranty failure carries the remainder of the original warranty. Warranty coverage
does not start over from the repair/replacement date.
4. Warranty coverage shall not exceed three (3) years from the date of production.
5. These warranty periods are effective March 1, 2010.
Dometic Direct Expansion, Self-Contained Systems
Product
Sale Type
Warranty Coverage
Turbo
Compact
Low Profile
OEM or Dealer Installed with Passport I/O
or Elite or mechanical controls.
2-Year Warranty
1st Year parts and labor, 2nd Year parts only.
Not to exceed three (3) years from date of production.
Pump warranty, see Pump section.
ECD
ECM
MCS
Catalog Sales
Parts: 1 year from date of purchase of unit.
Labor: 6 months from date of purchase of unit.
Not to exceed three (3) years from the date of
manufacture.
OEM or Dealer Installed
1-Year Warranty, parts and labor.
Not to exceed three (3) years from date of
manufacture.
Dometic Pumps, Compressors, Replacement Parts
Product
Sale Type
Warranty Coverage
Pumps
OEM or Dealer Installed with complete
system.
1-Year warranty, parts and labor.
Pump seals are not covered under warranty and
are sold “AS IS”.
Dealer Installed and Aftermarket sales.
1-Year warranty, parts only.
Pump seals are not covered under warranty and
are sold “AS IS”.
Compressors
Aftermarket sales
1-Year warranty, parts only
Replacement parts and components
Aftermarket sales
90-Day warranty, parts only
Dometic Air Conditioning Accessories
Product
Sale Type
Warranty Coverage
In-Duct Breathe Easy Air Purifiers
Aftermarket sales
1-Year warranty, parts only
UV bulb is not covered under warranty and is sold
“AS IS”.
SmartStart Control
Aftermarket sales
1-Year warranty, parts only
L-4111 ENGLISH
11
DOMETIC MARINE DIVISION
2000 N. Andrews Ave.
Pompano Beach, FL 33069 USA
Tel
+1 954-973-2477
Fax +1 954-979-4414
[email protected]
24/7 TECH SUPPORT FOR UNITED STATES AND CANADA
8:00 AM to 5:00 PM Eastern Time: 800-542-2477
After hours and weekends: 888-440-4494
INTERNATIONAL SALES AND SERVICES
Europe and the Middle East: +44 (0) 870-330-6101
For all other areas visit our website to find your nearest distributor.
dometic.com
L-4111 | 03/23/17
2675-Dometic-Workboat-Catalog.indd 44
3/1/17 4:08 PM

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement