Installation Instructions

INSTALLATION
INSTRUCTIONS
7106.9X1
PATIENCE
DECK MOUNT BATH FILLER
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
Certified to comply with ANSI A112.18.1M
ROUGHING-IN DIMENSIONS
8-1/2"
(216 mm)
14" (349 mm)
8" (203 mm)
Flat Blade Screwdriver
9"
(229 mm)
*Wrench
6-1/2"
(170 mm)
Adjustable Wrench
MOUNTING
SURFACE
6-1/2"
(170 mm)
*Hex key
*Supplied with fitting
CAUTION
Channel Locks
Turn off hot and cold water
supplies before begining.
• Install RING WASHER (1) and NUT (7) into spout
base recess. Insert SPOUT SHANK (3) through
center hole on mounting surface.
• Assemble RUBBER WASHER (4) and BRASS
WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (3). Align SPOUT ASSEMBLY and from
underside of ledge secure SPOUT ASSEMBLY
into position with LOCKNUT (6).
3-7/8"
(98 mm)
1-15/16"
(49 mm)
DIA.
3-13/16"
(97 mm)
1-1/4" (32 mm)
MAX.
1-1/8" (28 mm)
DIA.
3/4-14 MALE
N.P.T. INLETS
1-1/2" (38 mm) MAX.
3"
(76 mm)
1-3/16"
(30 mm) DIA.
(C)
(H)
*Supplied with Fittings
1 SPOUT ASSEMBLY
8"
(205 mm)
2-1/2"
(64 mm)
DIA.
12" (304 mm) MAX
1-1/16"
(27 mm)
DIA.
2 PREPARE TUBE AND TEE ASSEMBLY
• Prepare TUBE and TEE ASSEMBLY (1) to fit center to center
VALVE (2) location . If necessary, cut and/or bend TUBING carefully.
Make sure tube bend is close to the TEE (1) so that it will not effect
the compression joint at the VALVE CONNECTION.
• Remove COUPLING NUT (3) and FERRULE (4) from each
VALVE (2) and slide onto TUBING (5).
4
3
1
5
3
4
ADJ. 6-1/2 TO 12
SPOUT
ASSEMBLY
SPOUT RECESS
4
1
3
2
MOUNTING
SURFACE
MOUNTING
SURFACE
2
5
6
7
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2017
NOTE: VALVE inlets are 3/4-inch NPT male.
-1-
M965820 (8/17)
3 VALVE ASSEMBLY
• Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.
• Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4)
into mounting holes from underside of ledge.
• Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING
(7) is properly seated on SHANK (6). Push COUPLING (8 or 8a) into
TEE (5) and attach to SPOUT SHANK (6) and tighten. For 4508.901
use a 10 mm (3/8") hex key.
9
• Thread of VALVE BODY (4) should extend at least 5/16 inch above
MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).
11
MOUNTING
SURFACE
10
9
• Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and
thread onto valves until snug against internal stop.
• Tighten LOCKNUT (1) to secure VALVE (4) position.
• Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4)
and tighten COUPLING NUT (13) firmly.
10
• Connect HOT water supply to inlet of left VALVE and COLD water
supply to inlet of right VALVE using appropriate connector.
7
12
10
5/16'' MIN.
4
HOT
9
11
4
5
8a
1
12
3
MOUNTING
SURFACE
2
6
13
8
COLD
13
FOR FITTING
LESS SPRAY
INSTALL HANDLES
• Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without a spline is facing up. See figure "A".
Tighten STEM SCREW (3) to secure ADAPTER (1).
THREAD ON
TO DECK
ADAPTER
INSTALL
4
• Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting
male teeth on ADAPTER (1) to female teeth in HANDLE (4).
TOP
• Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5)
until snug against mounting surface.
1
3
Figure "A"
2
SPLINE END DOWN
5
5 SERVICE
To change direction of handle rotation, proceed as follows:
• Turn valve to OFF position. Unthread HANDLE BASE (1) from
DECK ADAPTER (2).
• Pull HANDLE ASSEMBLY off VALVE STEM (3).
REMOVE
HANDLE
HANDLE
ASSEMBLY
• Remove SPRING CLIP (4). Lift STOP WASHER (5), turn 90˚ and
replace. Replace SPRING CLIP (4).
• Find correct position of HANDLE ASSEMBLY by adjusting male
teeth on VALVE STEM (3) to female teeth in HANDLE.
• Thread HANDLE ASSEMBLY onto DECK ADAPTER (2) until snug
against mounting surface.
-2-
90˚
4
3
5
2
M965820 (8/17)
6 HAND SHOWER INSTALLATION
• Install RUBBER RING (2) on SPRAY ESCUTCHEON (1) and install SPRAY ESCUTCHEON
(1) through fifth hole on tub ledge (12" max from Spout) making sure the SPRAY ESCUTCHEON
(1) opening is directed toward tub center. Install RUBBER WASHER (3), BRASS WASHER (3a) and
LOCKNUT (4) from underside of ledge. Be sure RUBBER RING (2) is properly seated in
ESCUTCHEON (1). Install RUBBER WASHER (3) and LOCKNUT (4) from underside of ledge.
11
9
• Secure SPRAY ESCUTCHEON (1) by tightening LOCKNUT (4).
6
• Slip SHOWER HOSE (7) with HOSE CONNECTOR through SPRAY HOLDER (5) and ESCUTCHEON
(1) from above deck. Note: SPRAY HOLDER (5) must be separate from ESCUTCHEON (1) to get
SPRAY HOSE (7) through ESCUTCHEON (1). Make sure threads on SPRAY HOLDER (5) are facing
the SPRAY ESCUTCHEON (1). Install CHECK VALVE (11) and
9
SEAL (8) on SPRAY HOSE (7) and connect HOSE (10) to
7
SPRAY HOSE (7). Install SEAL (8) on SPRAY HOSE (7) at
5
HAND SHOWER (9) connection and connect HAND SHOWER (9)
10
to SPRAY HOSE (7).
1
2
3
4
8
12
NOTE: When not in use, HAND SHOWER should be seated
in the HOLDER.
7 TEST INSTALLED FAUCET
4
• Turn VALVES (1) to "off" position.
• With handles in "off" position, turn on water supplies and check
all connections for leaks.
1
1
• Operate both handles and flush water lines thoroughly.
• Check SPOUT (2) mounting for leaks.
• Lift HANDSHOWER (3) from holder, direct spray into
tub, lift TRANSFER KNOB (4) to check HANDSHOWER
(3) and HOSES for leaks.
3
• Turn VALVES "off".
• If spout drips, operate handles several times from OFF
to ON position. Do not force - handles turn only 90˚.
2
CAUTION: The flow rate of this Tub Filler exceeds 20
gallons/minute at higher water pressure.
Do not fill bathtub unattended.
8 Before the bathroom is completely finished, you may
2
want to remove spout, handshower, and handles.
1
• To remove handles, reverse steps in SE 4.
• To remove SPOUT (1), proceed as follows:
– Lift TRANSFER ROD (7) and unscrew KNOB (2).
– Remove SET SCREW (3) using 5 mm hex wrench supplied.
– Lift SPOUT (1) off SHANK (4) carefully and remove
RUBBER RING (5).
– Unscrew SHANK SLEEVE (6) and lift TRANSFER ROD (7) from
SHANK (4).
– Reverse sequence to re-install SPOUT (1). Be sure RUBBER
RING (5) is properly seated in its recess at the base of the
SPOUT (1). Make certain SET SCREW (3) is properly aligned
and tight so that SPOUT (1) is locked in place.
3
Hex wench, supplied
5
7
6
4
9 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
-3-
M965820 (8/17)
PATIENCE
DECK MOUNT
BATH FILLER
M970278-YYY0A
LIFT ROD & KNOB
MODEL NUMBER
7106.9X1
M910270-0070A
STREAM
STRAIGHTENER
Replace the “YYY” with
appropriate finish code
M962850-YYY0A
BUTTON AND SCREW
A952459-0020A
TRANSFER
ROD ASSEMBLY
M970285-YYY0A
HANDLE
M962619-0070A
DECK ADAPTER KIT
POLISHED CHROME
002
BRUSHED NICKEL
295
M911705-0070A
RUBBER RING
LEGACY BRONZE
278
M907877-YYY0A
SPOUT ESCUTCHEON
POLISH NICKEL
013
030278-0070A
TRANSFER
SEAL KIT
030275-0070A
SHANK SLEEVE KIT
918049-0070A
STEM ADAPTER
030274-0070A
SHANK
MOUNTING KIT
918555-0070A
HANDLE SCREW
994053-0070A
VALVE
1660142-YYY0A
HAND SHOWER
012668-0070A
SHANK KIT
M970280-YYY0A
HAND SHOWER
HOLDER
M961634-0070A
VALVE
MOUNTING KIT
028679-0070A
TUBE & TEE
ASSEMBLY
028699-0070A
COUPLING FOR
TRANSFER
033760-0070A
HAND SHOWER SEAL KIT
012078-0070A
VALVE COUPLING KIT
A952849-0070A
CHECK VALVE
028667-0020A
HAND SHOWER HOSE
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
051343-0070A
HOSE KIT
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
-4-
M965820 (8/17)
Download PDF