This device complies with part 15 of the FCC Rules

NOTICE:
This equipment has been tested and it complies with
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2) This device must accept any interface received,
including interface that may cause undesirable
operation.
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interference when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful
interference in which case the user will be required to
correct the interference at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
0
Using the ArgoxScan AS-8150/ 8250 (Rev.B)
The ArgoxScan can automatically scan barcode at a distance.
Simply aim and pull the trigger. Code scanning is performed
along the center of the light bar emitted from the reading
window. This bar must cover the entire code.
Recommended Steps
When the required settings have been configured, all settings
are stored in non- volatile memory of the scanner after
reading EXIT Label. Recommended steps are as follows.
1)
Set the right host interface for your scanner.
(The scanner is in factory default shown as bold label)
2)
Set interface to optimize protocol of the scanner with
your host in interface section.
3)
Set system control of the scanner, such as specific
adjustments double confirm, indicator and scanning
mode which you prefer using in the system control
section.
4)
Set code options of the scanner for your usage in the
code option section. You must make sure to enable the
symbology first, then Min./Max. code length, code ID
checksum and truncate digits are also converted.
5)
Set string format of the scanner, such as preamble,
postamble Prefix, suffix, code ID and code name
transmission for your application in the string format
section.
Note: If it stil does not work properly. Please contact your
dealer for further information.
1
CONTENTS
Chapter 1 Introduction
Introduction
Default Setting ……………………………………….
ArgoxScan AS-8150/ 8250 (Rev.B)
specification ………………..
Programming the ArgoxScan……………………..
5
6
9
Chapter 2 Parameter Setting
Interface
Interface Selection …………………………………..
USB HID Keyboard……………………………….…
RS-232 …………………………………………….….
Pin Assignments …………………………………….
11
12
15
18
System Control
Scan mode...………………………………………….
Indication …………………………..…………………
19
25
Code Option
UPCA ……………………………………..………….
UPCE …………………………………………………
EAN-13 ……………………………………………….
EAN-8 …………………………………………………
Code 39 ………………………………………………
Interleaved 2 of 5 ……………………………………
Industrial 2 of 5 ………………………………………
Matrix 2 of 5 Eur ……………………………………
Codabar ………………………………………………
Code-128 ……………………………………………
Code-93 ………………………………………………
Code-11 ………………………………………….……
MSI/Plessey ………………………………………….
27
32
36
40
44
48
50
52
54
57
61
64
66
2
UK/Plessey …………………………………………..
Telepen ……………………………………………….
Standard 2 of 5 ………………………………………
China Post ……………………………………………
Italian pharmacode ………………………….………
GS1 Data Omniidirectiona (RSS-14)……..……….
GS1 Databar Limited (RSS- Limited )………..……
GS1 Databar Expanded (RSS-Expanded) ………..
String Format
String Setting / Transmission
(Prefix/Suffix)…………………………………………
String Setting / Transmission
(Preamble/Postamble)………………………………
String Setting / Transmission
(Insert Group Characters)…………………………..
String Setting / Transmission
(Others)…….…………………………………………
Datamagic…………………………………………….
69
71
73
75
77
79
81
83
85
87
89
93
95
Appendix
Test Chart ……………………………………………. 101
ASCII Code Table …………………………………… 104
Parameter setting List ………………………………. 105
3
Introduction
Installation RS-232
1)
2)
3)
4)
5)
Disconnect power to the terminal/computer.
Connect the appropriate interface cable and external
power supply (DC adapter) to the scanner.
Plug the serial connector into the serial port on the back
of your computer/terminal. Tighten the two screws to
secure the connector to the port.
Plug the power pack into a power source.
Once the scanner has been fully connected, turn the
terminal/computer power back on.
USB HID (Simulate with keyboard wedge)
1)
2)
Connect the USB cable between scanner and PC.
Windows will automatically detect the USB device.
USB Com
1)
2)
Connect the USB cable between scanner and PC.
Windows will automatically detect the USB device.
Note: If any of the above operations is incorrect, turn off the
power immediately and check any improper
connections. Go through all above steps again.
4
Default setting
For each barcode shown as below:
Code Type
Read
Enable
3000
UPC-A
UPC-E
EAN-13
EAN-8
Code-39
Interleaved
2 of 5
Industrial
2 of 5
Matrix 2 of 5
Codabar
Code-128
Code-93
Code-11
MSI/Plessey
UK/Plessey
Telepen
Standard 2 of 5
GS1databar
Checksum
Checksum
Code
Verification Transmission
ID
Enable
Enable
V
V
V
V
V
V
V
V
V
V
V
V
V
*
V
i
-
V
A
E
F
FF
-
i
-
-
B
%
#
&
O
@
@
S
i
-
-
R4
-
-
RL
-
-
RX
V
V two digits
V One digit
V
V
Omnidirectiona
GS1databar
Limited
GS1databar
Expanded
China Post
Italian
Pharmacode.
t
p
5
ArgoScan 8150 / 8250(Rev.B)
Specification
Model 8150/8250
Operational
Light Source
660 nm Visible Red LED
Optical System
2048 pixel CCD
(Charge-coupled device)
Depth of Scan Field
0-250 mm
(CODE 39, PCS=90%, 20mils)
Scanning Width
120 mm
Scan Speed
Resolution
200 scans/sec
0.1mm(4mils) Code39,PCS=90%
Print Contrast
Scanning Angle
Decode Capability
30% or more
Front: 60° Rear: 60° Yaw: 75°
Auto-discriminates all standard
barcodes; Other symbologies can be
ordered optionally (2D symbologies for
8250 and 8312 only)
Beeper Operation
7 tones or no beep
Indicator
Green led
Mechanical
Length
182 mm
Width-handle
26 mm
Width-head
74 mm
Depth-handle
51 mm
Depth-head
Weight
35 mm
160 g (cable not included)
Cable – K/B wedge
Straight 2.0 m
6
Cable – universal
Straight 2.3 m
type
Cable- USB
Connector type
Straight 2.0 m
RJ-45 phone jack connector
Case material
PC
Cushion material
Rubber
Electrical
Input Voltage
5 VDC ± 0.25V
Power - Operating
1275 mW
Power - Standby
600 mW
Current - Operating
255 mA @ 5 VDC
Current - Standby
120 mA @ 5 VDC
DC Transformers
Class 2; 5VDC @ 450 mA
Agency listing
UL, FCC Class A, CE
Environmental
Operating
0℃ to 45℃
Temperature
(32℉ to 113℉)
Storage
-40℃ to 60℃
(-40℉ to 140℉)
Humidity
5% to 90% relative humidity,
non-condensing
Light Level
Up to 60000 Lux.
.
Shock
Contaminants
1.5m drop onto concrete
Seals to resist airborne particulate
contaminants
Ventilation
None required
Programming
7
Manual (Reading special barcode) DOS
Programming
command through RS-232, Windows
method
configuration program
Program upgrade
Enabled by built-in flash memory
Programmable
Code type selection, check digit
characteristics
selection Decoding option Decoding
option Transmitted character delay,
Header selection, trailer selection,
message suffix, good read beep tone
and volume, scanner trigger selection
Keyboard emulation type
(intermessage delay, keyboard type
and keyboard language)
Serial interface type (ACK/NAK,
Xon/Xoff, RTS/CTS, good read LED
control, start/stop bits)
8
Programming scanners
To program the AS-8150/ 8250 (Rev.B) , you must scan a
series of programming barcode in the correct order. On the
last page of this manual, you will see a table of alphanumeric
barcodes, which are used to program the various options
presented.
To program each option, you must:
1. Scan the Program barcode on the parameter setting part.
2. Enter the option mode by scanning the Option Bar Code
(also on the Parameter setting part).
3. To the right of the option barcode, the necessary
alphanumeric inputs are listed. Scan these alphanumeric
entries from the last page . To confirm above steps, you
must scan the Finish barcode on the last page.
4. Once you have finished programming. Scan the Exit
barcode, listed on the lower right hand corner of each
parameter setting part.
9
Program Barcode
Program
Option Bar Code
Option
Alphanumeric Entry
Keyboard Wedge
00
Interface
RS-232
01
selection
Wand emulation
02
USB
03
/RS-232
04*
Auto detection
Exit
Option Barcode
On the last page
Exit Barcode
Finish barcode
10
Interface Selection
This decoder built-in scanner comes in one model and
supports interfaces such as keyboard wedge, RS232 serial
and the latest USB interface. In most of the cases, simply
selecting an appropriate cable with a device code will work
for a specific interface.
Interface selection: You can change factory interface
default for another type interface. By plugging different
cables, setting right interface, the scanner will change to
another interface. However, you must make sure which cable
you need.
RS232/ USB HID Auto detection: By setting this function, it
will automatically select the RS-232 or /USB HID interface for
the user.
Program
Option Bar Code
Option
Alphanumeric
Entry
Interface selection
RS-232
01
USB HID
03
RS232/
USB HID
04*
Auto detection
Exit
Note:*-Default
11
USB HID Keyboard
USB HID Keyboard Layout: The selecting of keyboard
layout supports languages other than USA keyboard layout.
First you need to confirm country language that you desire. In
DOS, using command “keyb” to select the desirable
keyboard layout or in WINDOWS entry “Control” then pops
“Keyboard” to select country from the “language” item. For
details, please refer to your DOS or WINDOWS user’s
manual.
Function Key: Set Enable, scanner can output code as
pressing function-key in your application program while the
barcode datas contain ASCIIvalues between 0116 to 1F16.
Refer to ASCII table.
Numeric Key: The Keypad has to be selected if your
application program is only keypad numeric code acceptable.
The scanner will output code as you press the numeric
keypad when it reads a numeric digit. (The keypad is on the
right side of keyboard, and Num Lock control key is also on.)
If Alt+Keypad is selected, the data characters will be
transmitted as “Alt” + numbers. For example, when sending
character “A”, the actual sending will be
“Alt”+65. It is also
useful when using non-English OS and keyboard layout.
Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”,
scanner can get Caps Lock status.
12
Program
Option Bar Code
Option
Alphanumeric
Entry
Keyboard layout
USA
00*
Belgium
01
Danish
02
France
03
Germany
04
Italian
05
Portuguese
06
Spanish
07
Swedish
08
Switzerland
09
UK
10
Latin American
11
Japanese
12
Disable
00
Enable
01*
Alphabetic key
00*
Numeric keypad
01
Function key
Numeric key
(Num lock state
13
only)Alt+Keypad
02
Caps lock”ON”
00
Caps lock”OFF”
01*
Caps lock
Exit
14
RS-232
CTS: Clear To Send (Hardware Signal)
RTS: Request To Send (Hardware Signal)
Xon: Transmit On (ASCII Code 1116)
Xoff: Transmit Off (ASCII Code13 16)
Flow control:
None-The communication only uses TxD and RxD signals
without regard for any hardware or software handshaking
protocol.
RTS/CTS-If the scanner wants to send the barcode data to
host computer, it will issue the RTS signal first, wait for the
CTS signal from the host computer, and then perform the
normal data communication. If there is no replied CTS signal
from the host computer after the timeout (Response Delay)
duration, the scanner will issue a 5 warning beeps.
Xon/Xoff- When the host computer is unable to accept data,
it sends a Xoff code to inform the scanner to suspend data
transmission, and Xon to continue.
ACK/NAK- When the ACK/NAK protocol is used, the
scanner waits for an ACK (acknowledge) or (not
acknowledge) from the host computer after data transmission,
and will resend in response to a NAK.
Inter-character delay: This is the delay time between data
character’s data output. It is also same as Inter-char. delay of
keyboard wedge.
Block transmission delay: This is the delay time between
barcode data output. It is also the same as Block
transmission delay of keyboard wedge.
Response delay: This delay is used for serial
15
communication of the scanner to wait for handshaking
acknowledgment from the host computer.
Program
Option Bar Code
Option
Alphanumeric
Entry
Flow control
None
00*
RTS/CTS
01
Xon/Xoff
02
ACK/NAK
03
00-99 (msec)
00-99
00*
Inter-character delay
00-99 (10 msec)
00-99
00*
Block transmission
delay
00-99 (100 msec)
00-99
20*
Response delay
Exit
16
Program
Option Bar Code
Option
Alphanumeric
Entry
Baud rate
Parity
600 BPS
01
1200 BPS
02
2400 BPS
03
4800 BPS
04
9600 BPS
05
19200 BPS
06
38400 BPS
07
57600BPS
08
115200BPS
09*
None
00*
Odd
01
Even
02
8 bits
00*
7 bits
01
One bit
00*
Two bits
01
Data bit
Stop bit
Exit
17
Pin Assignments
RS-232 DB-9F Connector (To Host Side):
Pin
Definition
1
NC
2
TXD
3
RXD
4
NC
5
GND
6
NC
7
CTS
8
RTS
9
VCC (+5V)
5
4
3
2
1
18
9
8
7
6
Scan
Scanning mode:
Good-read off-The trigger button must be pressed to
activate scanning. The light source of the scanner stops
scanning when there is a successful reading or no code is
decoded after the Stand-by duration elapsed.
Momentary-The trigger button acts as a switch. Press button
to activate scanning and release button to stop scanning.
Alternate-The trigger button acts as a toggle switch. Press
button to activate or stop scanning.
Timeout off-The trigger button must be pressed to activate
scanning, and the scanner stops scanning when no code is
decoded after the Stand-by durationhas elapsed.
Continue-Scanner always keeps reading, and it does not
matter when the trigger button is pressed or duration has
elapsed.
Test only-For test of scan performance only. This should not
be used to be utilized to check the accuracy of transmitted
data.
Double read timeout: It determines the duration of Double
confirm. For example, if you set 5 times in Double confirm
and set 10 milliseconds in Double read timeout, the
decoder will decode a bar code 5 times in 10 milliseconds.
You need to turn on Double confirm to use this feature.
Double confirm: It determines how many times the decoder
needs to confirm a bar code.
Supplement Check Counter: It will be more reliable to read
the barcode an extension (supplement) like UPCE/A or
EAN-8/13, but it slows down the decoding speed when this
counter is set more.
19
Program
Option Bar Code
Option
Alphanumeric
Entry
Scanning mode
Good-read off
00
Momentary
01*
Alternate
02
Timeout off
03
Continue (led on)
04
Test only
05
Continue (led off)
06
01-99 (second)
00-99
06*
Stand-by duration
01-99 (10 msec)
01-99
50*
Double read timeout
Double confirm
00-99
00-09
(00: no double
00*
confirm)
00-99
00-99
(verifications)
5*
Supplement Check
Counter
20
Exit
Scan
Global min./max. code length: These are to define the min/
max readable code length of all symbologies. Code length
less than min. code length or more than max. code length will
not be read. In general, you can set the same value for both
min. and max. reading length to force the fixed length
barcode decoded. The values of setting have no effect on
certain symbologies with fixed length. You can specify the
settings for individual barcode by the min/max code length
setting of each barcode.
Notes 1): Please set the min/max length if you have special
demand for individual barcode.
2): Include the Check sum digits if you want to set
Global min/max code length.
Inverted image scan: Set Enabled the scanner will scan
both black/white barcode with white/black background.
CTS trigger: This operation enables an external device to
control scanning. The CTS trigger is controlled by applying
an external trigger signal to the CTS input. When active, this
signal causes scanning to begin as the scanner’s trigger is
depressed.
21
Program
Option Bar Code
Option
Alphanumeric
Entry
00-99
00-99
4*
Global min. code length
00-99
04-99
99*
Global max. code length
Disable
00*
Enable
01
Disable
00*
Enable
01
Inverted image scan
CTS trigger
Exit
22
Scan
Position indication: If the function is enabled, scan beam
will flash as a pointer to help you aim at the bar code prior to
scanning. The code will not be scanned until you press the
trigger.
Stand mode selection: Normally activated with continuous
mode. If it is set as LED “off”, the scanner red beam will turn
off automatically if not used, but will turn on again
immediately when scanning bar codes.
Program
Option Bar Code
Option
Alphanumeric
Entry
Position indication
Disable
00*
30 second
01
60 second
02
90 second
03
120 second
04
150 second
05
180 second
06
Continue
07
Exit
23
Indication
Power on alert: After power-on the scanner will generate an
alert signal to indicate a successful self-test.
LED indication: After each successful reading, the LED
above the scanner will light up to indicate a good barcode
reading.
Beeper indication: After each successful reading, the
scanner will beep to indicate a good barcode reading, and its
Beep loudness, Beep tone freq. and Beep tone duration
are adjustable.
Beep loudness/Beep tone freq./Beep tone duration: You
can adjust Beep Loudness, Beep tone and Beep duration for
a good reading to your preferred setting.
24
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00
Enable
01*
00-07
00-07
Power on alert
LED indication
Beeper indication
07*
Beep loudness
00-99 (100Hz)
00-99
40*
Beep tone freq.
00-99 (10 msec)
00-99
10*
Beep tone duration
Exit
25
UPCA
Format
Leading
Zero
Data Digits
(11 Digits)
Check
Digit
Read: Enable or disable the read function.
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: The leading or ending digits of
barcode data characters can be truncated when these values
are set to non-zero. It will beep instead of reading anything
when the truncate value is more than the barcode data digits
or the value of Truncate Leading is overlapped with that of
the Ending. The maximum value of truncate digits is 15.
Code ID setting: Code ID setting is a character used to
represent the symbol upon a successful reading. A Code ID
setting is prefixed to the data begin or end transmitted if the
feature is selected. If you want an application to transmit
Code ID, you must set Code ID transmission to Enable first.
Refer to Code ID transmission.
26
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
0-15
00-15
Read
Check-sum transmission
Datamagic
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< A >*
Code ID setting
Exit
27
UPCA
Insertion group number selection: The scanner offers max.
two insertion groups for one symbology. By setting one or two
digits to indicate which insertion group you want to insert.
You may refer to Character insertion. The function is to insert
specific characters as a group into the transmitted data of
selected symbologies. Enable the group insertion by
selecting the group number.
Example: Group 2 → set 02 or 20.
Group 1 and 4 → set 14 or 41.
Notes 1): Group number set to “0” means that no group
insertion required.
2): Details about the Insert Group settings please refer
to page 98~101, and page 107 ASCII code table.
Supplement digits: The Supplement digits barcode is the
supplemental 2 or 5 characters for WPC code.
Format
Leading Data Digits Check
Zero
(11 Digits) Digit
28
Supplement Digits
2 or 5 or
UCC / EAN 128
Program
Option Bar Code
Option
Alphanumeric
Entry
00-44
00-44
00*
Insert group number
selection
Supplement digits
None
00*
2 digits
01
5 digits
02
2,5 digits
03
UCC/EAN 128
04
2, UCC/EAN 128
05
5, UCC/EAN 128
06
All
07
Exit
29
UPCA
Truncation / Expansion: The leading “0” digits of UPCA
data characters can be truncated when the function is
enabled.
Program
Option Bar Code
Option
Alphanumeric
Entry
None
00
Truncate leading
01*
Truncation/
zero
Expansion
Expand to EAN13
02
00-99
00-99
(verifications)
5*
Supplement Check
Counter
Exit
The
30
UPCE
Read: Format
Leading
Zero
Data Digits (6
Digits)
Check
Digits
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Read
Check-sum
transmission
Datamagic
31
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< E >*
Code ID setting
Exit
32
UPCE
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Supplement digits:
Format
Leading
Zero
Data Digits Check
(6 Digits) Digit
Supplement Digits
2 or 5 or
UCC/EAN 128
Expansion: The expansion function is used only for UPCE
and EAN-8 code reading. It extends to 13-digits with “0” digits
when the feature is enabled.
Example: Barcode “0123654”
Output: “0012360000057”
UPCE-1: Enable scanner to read UPCE with leading digit 1.
Program
Option Bar Code
Option
Alphanumeri
c Entry
00-44
00-44
00*
Insert group number
selection
Supplement digits
None
00*
2 digits
01
5 digits
02
2,5 digits
03
UCC/EAN 128
04
33
Truncation/Expansion
2, UCC/EAN 128
05
5, UCC/EAN 128
06
All
07
None
00*
Truncate leading
01
zero
Expand to EAN13
02
Expand to UPCA
03
Disable
00*
Enable
01
Disable
00*
Enable
01
00-99
00-99
(verifications)
05*
Expansion
UPCE-1
Supplement Check
Counter
Exit
34
EAN-13
Read: Format
Data Digits (12 Digits)
Check Digits
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Truncate leading zero: Refer to Truncation / Expansion of
UPCA.
Program
The
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Read
Check-sum
transmission
Datamagic
35
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
Exit
36
EAN-13
Code ID setting: Refer to page 30 Insertion group number
selection of UPCA.
Insertion group number selection: Refer to Insertion group
selection of UPCA.
Supplement digits:
Format
Data Digits
(12 Digits)
Check
Digits
Supplement Digits
2 or 5 or
UCC / EAN 128
ISBN/ISSN: The ISBN (International Standard Book Number)
and ISSN (International Standard Serial Number) are two
kinds of barcode for books and magazines. The ISBN is 10
digits with leading “978” and the ISSN is 8 digits with leading
“977” of the “EAN-13” symbology.
Example: Barcode “9789572222720” - Output: “9572222724”
Example: Barcode “9771019248004” - Output: “10192484”
Program
Option Bar Code
Option
Alphanumeric
Entry
00-ffH ASCII
00-ffH
code
< F >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
37
Supplement digits
None
00*
2 digits
01
5 digits
02
2,5 digits
03
UCC/EAN 128
04
2, UCC/EAN 128
05
5, UCC/EAN 128
06
All
07
Disable
00*
Enable
01
00-99
00-99
(verifications)
05*
ISBN/ISSN
conversion
Supplement Check
Counter
Exit
38
EAN-8
Read: Format
Data Digits
(7 Digits)
Check
Digits
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 30
Insertion group number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Read
Check-sum
transmission
Datamagic
39
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
Code ID setting
Two characters
00-ffH, 00-ffH
00-ffH ASCII
< FF >*
code
00-44
00-44
00*
Insert group number
selection
Exit
40
EAN-8
Supplement digits: Format
Data Digits
(7 Digits)
Check
Digits
Supplement Digits
2 or 5 or
UCC/EAN 128
Truncation / Expansion: Refer to Truncate Leading zero of
UPCE.
Expansion: Refer to Expansion of UPCE.
Program
Option Bar Code
Option
Alphanumeric
Entry
Supplement digits
None
00*
2 digits
01
5 digits
02
2,5 digits
03
UCC/EAN 128
04
2, UCC/EAN 128
05
5, UCC/EAN 128
06
All
07
None
00*
Truncate leading
01
Truncation /
zero
Expansion
Expand to EAN13
41
02
Disable
00*
Enable
01
00-99
00-99
(verifications)
05*
Expansion
Supplement Check
Counter
Exit
42
Code 39
Read: Format
Start
“★”
Data Digits
( Variable)
Checksum
(Optional)
End
“★”
Check-sum verification: The checksum of Code-39 is
optional and made as the sum module 43 of the numerical
value of the data digits.
Check-sum transmission: By setting Enable, checksum
will be transmitted.
Max./Min. code length: Each symbology has its own
Max./Min. Code Length. They can be set to qualify data entry.
If their Max./Min. Code Length is zero, the Global Min./Max.
Code Length is in effect. The length is defined as to the
actual barcode data length to be sent. Labels with lengths
that exceed these limits will be rejected. Make sure that the
Minimum length setting is no greater than the Maximum
length setting, or otherwise all the labels of the symbology
will not be readable. In particular, you can see the same
value for both Minimum and Maximum reading length to force
the fixed length barcode decoded.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Read
43
Check-sum transmit
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Disable
00*
Enable
01
00-64
00-64
/verify
Datamagic
00*
Max. code length
00-64
00-64
01*
Min. code length
0-20
00-20
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
<*>
Code ID setting
Exit
44
Code 39
Insertion group number selection: Refer to page 30
Insertion group number selection of UPCA.
Format: The Full ASCII Code-39 is an enhanced set of
Code-39 that is data with a total of 128 characters to
represent Full ASCII code. It is combined with one of the
digits +, %, $ and/ with one of the alpha digits (A to Z).
Append: This function allows several symbols to be
concatenated and treated as one single data entry. The
scanner will not transmit the embedded appending code
(space for Code-39). If Enable and other symbols were read
again with the appended code, then codes will be transmitted
without Code ID, Preamble and Prefix. When a symbol is
decoded without the appended code, the data will be
transmitted without Code ID and Prefix, but the Postamble
Suffix codes are appended. This function is used when the
first number of code 39 is a space. Example: □123456.
Start/end transmission: The start and end characters of
Code-39 are“★”. You can transmit all data digits including two
“★”.
Program
Option Bar Code
Option
Alphanumeric
Entry
00-44
00-44
00*
Insert group number
selection
45
Standard
00*
Full ASCII
01
Disable
00*
Enable
01
Disable
00*
Enable
01
Format
Append
Start/end
transmission
Exit
46
Interleaved 2 of 5
Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Check-sum verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Check-sum transmission: By setting Enable, checksum
will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 30
Insertion group number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Read
Check-sum
transmit/verify
47
*
Disable
00
Enable
01
00-64
00-64
Datamagic
00*
Max. code leading
00-64
00-64
00*
Min. code leading
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< i >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
48
Industrial 2 of 5
Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 30
Insertion group number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
00-64
00-64
Read
Datamagic
00*
Max. code length
49
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< i >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
50
Matrix 2 of 5 Eur
Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Checksum Verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 30
Insertion group number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Read
Checksum Transmit/
Verify
51
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< B >*
00-44
00- 44
Code ID setting
00*
Insert group number
selection
Exit
52
Codabar
Read: Format
Start
Data Digits (Variable)
Checksum (Optional) End
Checksum Verification: The checksum is made as the sum
module 16 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
01
Read
Checksum
Enable
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Transmit/Verifiy
53
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII code
00-ffH
< % >*
Code ID setting
Exit
54
Codabar
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Start/End type: The Codabar has four pairs of Start/End
patterns; you may select one pair to match your application.
Start/End Transmission: Refer to Start/End Transmission of
Code 39.
Program
Option Bar Code
Option
Alphanumeric
Entry
00-44
00-44
00*
Insert group number
selection
Start/End type
ABCD/ABCD
00*
abcd/abcd
01
ABCD/TN*E
02
abcd/tn*e
03
Disable
00*
Enable
01
Start/End
transmission
Exit
55
Code-128
Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Checksum Verification: The checksum is made as the sum
module 103 of all data digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00
Enable
01*
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Disable
00*
Enable
01
Read
Checksum
Transmit/Verify
Datamagic
Exit
56
Code-128
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Format: The Code-128 can be translated to UCC/EAN-128
format if it starts with a FNC1 character. The first FNC1 will
be translated to “]C1”,and next to be a field separator code as
<GS>(1D16).
]C1
Data
<GS> Data
Checksum
Program
Option Bar Code
Option
Alphanumeric
Entry
00-64
00-64
00*
Max. code length
00-64
00-64
01*
Min. code length
57
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< # >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Standard
00
UCC/EAN-128
01*
Format
Exit
58
Code-128
Append: When this function is enabled, it won't show the
data immediately if scanner reads a barcode that includes
FNC2 code. It will show all data until it read the barcode,
which doesn't have FNC2 code.
UCC/ EAN 128 ID setting: To set the code ID for
UCC/EAN-128 output format.
Field separator code: This feature is only used for
UCC/EAN-128 format. This Field separator code means you
can reassign second or after a FNC1 for your usage. The
default of ASCII code is <GS>(1D16).
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
00-ffH ASCII
00-ffH
code
< # >*
00-ffH ASCII
00-ffH
code
1DH*
Append
UCC/EAN-128
ID setting
Field separator code
Exit
59
Code-93
Read: Format
Data Digits Checksum1 Checksum2
(Variable)
(Optional)
(Optional)
Checksum Verification: The checksum is made as the sum
module 47 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum
will be transmitted.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Disable
00*
Enable
01
Read
Checksum
Transmit/Verify
Datamagic
Exit
60
Code-93
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
00-64
00-64
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
61
00-ffH ASCII
00-ffH
code
< & >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
62
Code-11
Read: Format
Data Digits Checksum1 Checksum2
(Variable)
(Optional)
(Optional)
Checksum Verification: The checksum is presented as the
sum module 11 of all data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00
Disable/One digit
01*
Checksum
Disable/Two digits
02
Transmit/Verify
Enable/One digit
03
Enable/Two digits
04
Read
63
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII code
00-ffH
< O >*
Code ID setting
00-44
00-44
00*
Insert group number
selection
Exit
64
MSI/plessey
Read: Format
Data Digits Checksum1 Checksum2
(Variable)
(Optional)
(Optional)
Checksum Verification: The MSI/Plessey has one or two
optional checksum digits. The checksum is presented using
3 kinds of methods Mod10, Mod10/10 and Mod 11/10. The
checksum1 and checksum2 will be calculated as the sum
module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Read
65
N/disable
00*
N/MOD 10
01
Checksum
N/Mod 10,10
02
Transmit/Verifiy
N/mod 11,10
03
Y/ Mod10
04
Y/ Mod 10,10
05
Y/ Mod 11/10
06
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< @ >*
66
Code ID setting
00-44
00-44
00*
Insert group number
selection
Exit
67
UK/plessey
Read: Format
Data Digits
(Variable)
Checksum1+2
(Optional)
Checksum Verification: The UK/Plessey has one or two
optional checksum digits. The checksum1 and checksum2
will be calculated as the sum module 10 or 11 of the data
digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00
Disable/Enable
01*
Enable/Enable
02
Read
Checksum
Transmit/ Verify
68
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< @ >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
69
Telepen
Read: IATA (International Air Transport Association).
Checksum Verification: The checksum is presented as the
sum module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Disable
00*
Enable
01
Read
Checksum
Transmit/Verify
Datamagic
70
00-64
00-64
00*
Max. code length
00-64
00-64
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< S >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Numeric only
00*
Full ASCII only
01
Format
Exit
71
Standard 2 of 5
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Check-sum verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Check-sum transmission: By setting Enable, checksum
will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable/Disable
00*
Disable/Enable
01
Enable /Enable
02
Read
Check-sum
Transmit/Verifyn
72
Disable
00*
Enable
01
00-64
00-64
Datamagic
00*
Max. code length
00-64
00-64
*JAC
00*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< i >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
73
China Post
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
00-64
00-64
Read
Datamagic
11*
Max. code length
74
00-64
00-64
11*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< t >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Exit
75
Italian Pharmacode (Code 32)
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
Leading “A”: If this function is enabled, each prefix of data
shall be A.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Read
Datamagic
76
00-64
00-64
12*
Max. code length
00-64
00-64
09*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
01-ffH
code
< p >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Disable
00*
Enable
01
Leading “A”
Exit
77
GS1 Databar Omnidirectional
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
UCC/EAN 128 emulation: Refer to Transmission, Code ID
transmission must be set as AIM ID enable. Then ]C1 will be
identified as the prefix of barcode data transmission.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Read
78
Disable
00*
Enable
01
0-15
00-15
Datamagic
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< R4 >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Disable
00*
Enable
01
UCC/EAN128
emulation
Exit
79
GS1 Databar Limited
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation
of RSS-14.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
0-15
00-15
Read
Datamagic
00*
Truncate leading
80
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< RL >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Disable
00*
Enable
01
UCC/EAN128
emulation
Exit
81
GS1 Databar Expanded
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to Insertion group
number selection of UPCA.
UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation
of GS1 Databar Omnidirectional.
Program
Option Bar Code
Option
Alphanumeric
Entry
Disable
00*
Enable
01
00-99
00-99
Read
99*
Max. code length
82
00-99
00-99
01*
Min. code length
0-15
00-15
00*
Truncate leading
0-15
00-15
00*
Truncate ending
00-ffH ASCII
00-ffH
code
< RX >*
00-44
00-44
Code ID setting
00*
Insert group number
selection
Disable
00*
Enable
01
UCC/EAN128
emulation
Exit
83
String setting / Transmission
(Prefix / Suffix)
Prefix / Suffix characters setting: Characters defined as
prefix or suffix characters will be transmitted immediately with
the scanned data for all symbologies. Up to 12 ASCII
characters can be defined as Prefix or Suffix.
Format of barcode data transmission:
Prefix Name Preamble ID
Code Barcode
Length
Data
ID Postamble
Suffix
Insert groups
.
Note Datamagic can help you up to 10
string with 12characters.
84
Program
Option Bar Code
Option
Alphanumeric
Entry
None
00*
1-22 characters
00-ffH ASCII
Prefix characters
code
setting
None
0D*
1-22 characters
00-ffH ASCII
Suffix characters
code
setting
Exit
85
String setting / Transmission
(Preamble/Postamble)
Preamble/ Postamble characters: Preamble or Postamble
characters will be appended to the data automatically for all
symbologies. However, the transmission will not activate
unless Preamble / Postamble transmission is enabled.
Preamble transmission: By setting Enable, Preamble will
be appended before the data transmitted.
Postamble transmission: By setting Enable, Postamble will
be appended after the data is transmitted.
Example:
Add a prefix/suffix or preamble/postamble for all symbologies.
In this example, you are sending a $ symbol as a prefix for all
symbologies.
Steps:
1) Scan Programming and Prefix characters setting barcode.
2) Use the ASCII code table to find the value of $→24.
3) Scan 2 and 4 from the barcode on the fold out back page.
4) Scan Finish from the barcode on the fold out page.
5) Scan Exit barcode.
86
Program
Option Bar Code
Option
Alphanumeric
Entry
None
00*
1-12characters
00-ffH ASCII
Preamble characters
code
setting
None
00*
1-12haracters
00-ffH ASCII
Postamble
code
characters setting
Disable
00*
Enable
01
Disable
00*
Enable
01
Preamble
transmission
Postamble
transmission
Exit
87
String setting / Transmission
(Insert Group Characters)
Insert G1/G2/G3/G4 character setting: The scanner
supports inserting two groups with each group 22 characters
into transmitted data of selected symbologies. The two
groups can be inserted into scanned data of the selected
symbologies or positioned at leading / ending of data. There
are a total four groups for utilization.
Insert data group position: To define the position of a group
to insert into bar code data. Please notice that the inserting
position of a group must not exceed the code length; or the
insertion will be positioned at the ending of data.
Notice: Default value “00” indicates the group to be
positioned at the leading of data. “64” represents for
positioning the group at the ending of data.
Insert data group setting procedure:
i. Define the characters of groups for insertion.
ii. Setup the inserting position of each group in
scanned data.
iii. Select one or two groups to insert into specific
bar codes. Please refer to the setting pages of
each bar code.
Example: Barcode “1 2 3 4 5 6”.
Output- Barcode “1 2 A B 3 4 C D 5 6”.
Steps:
1) Scan Programming and Insert G1 characters setting
barcode.
2) Use the ASCII code table to find the value of A→41,B→ 42.
3) Scan 4, 1 and 4, 2 from the barcode on the fold out back
page.
4) Scan Finish from the barcode on the fold out page.
88
5) Repeat the same procedure in Insert G2 characters
setting.
6) Scan Exit barcode.
6)
Insert data group 1-4 position. Please refer to ChapterTransmission, page 65 and to the specific barcode that
you want to use.
7)
Insert data group 1-4 position: The scanner offers 4
positions to insert among the symbols. The position
default value is “00” to indicate no character insertion.
In addition, make sure insertion positions are not
greater than the symbols; otherwise the insertion data
is not effective.
Program
Option Bar Code
Option
Alphanumeric
Entry
None
00*
1-12haracters
00-ffH ASCII
Insert G1 characters
code
setting
None
00*
1-12 characters
00-ffH ASCII
Insert G2 characters
code
setting
Exit
89
String setting / Transmission
(Insert Group Characters)
Program
None
00*
1-12 characters
00-ffH ASCII
Insert G3 characters
code
setting
None
00*
1-12 characters
00-ffH ASCII
Insert G4 characters
code
setting
8AI
None
00*
Insert G5 characters
1-12 characters
00-ffH ASCII
setting
code
8AJ
None
00*
Insert G6 characters
1-12 characters
00-ffH ASCII
setting
code
8AK
None
00*
Insert G7 characters
1-12 characters
00-ffH ASCII
setting
code
8AL
None
Insert G8 characters
1-12 characters
00*
00-ffH ASCII
code
None
00*
setting
8AM
90
Insert G9 characters
1-12 characters
00-ffH ASCII
code
None
00*
00-ffH ASCII
code
00-63
00*
setting
8AN
Insert G10 characters
setting
1-12 characters
00-63
(00: no
Insert data group 1
insertion)
position
Insert data group 2
00-63
00-63
(00: no
00*
insertion)
position
Insert data group 3
00-63
00-63
(00: no
00*
insertion)
position
Insert data group 4
00-63
00-63
(00: no
00*
insertion)
position
Exit
91
String setting / Transmission
(Others)
Code ID position: Upon using, the transmitting position of
Code ID can be selected to place Before Code Data or After
Code Data when it is transmitted.
Code ID transmission: If your application is needed to
transmit Code ID, you must set this to Proprietary ID or AIM
ID.
Code length transmission: A number of data digits can be
transmitted before the code data when Enable is selected.
The total length of the barcode is the number of barcode data
except Truncate Leading/Ending Digits. And the length is a
number with two digits.
Code name transmission: This function is to show
unknown barcode symbologies that include all readable
symbologies of the scanner. When Enable is selected,
Code Name will be transmitted before code data, to let you
know what kind of barcode symbology it is.
Case conversion: Setup the scanned data characters to be
transmitted all in upper case or lower case. For example: If
upper case is selected, “12aBcDeF” will be converted and
transmitted to host as “12ABCDEF”.
Program
Option Bar Code
Option
Alphanumeric
Entry
92
Before code data
00*
After code data
01
Disable
00*
Proprietary ID
01
AIM ID
02
Disable
00*
Enable
01
Disable
00*
Enable
01
Disable
00*
Upper case
01
Lower case
02
Code ID position
Code ID
transmission
Code length
transmission
Code name
transmission
Case conversion
*For barcode
data only
Exit
93
Datamagic
DataMagic has eight functions. The Scanner allows a
maximum of 10 Rules. Functions are described below.
Important
Data Magic default is
disabled. To enable Data Magic function, go to
Code Option and find Data Magic column to
enable it.
Each Rule has the following structure:
Leading+RuleNo.+Action+Parameter1+ Parameter2
Leading:
9 indicates DataMagic
RuleNo.:
0~9 indicates Rule No. 0 ~ No.9
RULE1
RULE2
RULE3
RULE4
RULE5
RULE6
94
RULE7
RULE8
RULE9
RULE10
Action:
0~9,
0->Insert Front,
1->Cut Front,
2->Cut Back,
3-> Replace,
4->Keep Front,
95
5->Keep Back,
6-> Find & Cut Front,
7-> Find & Cut Back.
8->Insert Back,
9->Erase
Parameter1: Each function is indicated differently.
Parameter2: Each function is indicated differently.
To erase all of the DataMagic setting values, just scan the
barcode below.
96
To display all of the current related setting results, scan:
Program
OR
(DataMagic settings)
(Inserted Group settings)
97
Example Data
Original Barcode Data: ARGOX89121121
Insert Group 1: ARGOX
Insert Group 2: argox
Insert Group 3: GOX
Insert Group 4: Tel:
Insert Front: In the original data, insert a group at a specified
position from the front. Para1 specifies the insert position
(starting from position 0). Para2 specifies the group to insert.
Example:
Program
RuleNo
Action
Para1
Para2
RULE1
Insert
0
0
5
Exit
4
Front
RULE1 (Rule No.) Insert Front (Action) -- at the 5th position
from the front (Para1) insert Group 4 (Para2).
Data : ARGOX89121121
Result: ARGOXTel:89121121
98
Programming for the example above:
Program
RULE1
Insert Front
Para1 (Two digits)
Para2 (Two digits)
Finish
Exit
99
Test Chart (Bar code samples marked with
symbol “*” are enabled initially.)
CODABAR
CODE-11
CODE-128 *
CODE-39 *
CODE-93
EAN-13 *
100
STANDRAD-25
EAN-8 *
INDUSTRIAL-25
UPCE *
INTERLEAVED-25 *
101
MATRIX 25
MSI/PLESSEY
UPCA *
UK/PLESSEY
GS1 dat bar
102
ASCII Code Table Note:
L
H
0
0
For keyboard wedge only.
1
Null
0
1
NUL
DLE
1
Up
F1
SOH
DC1
2
Down
F2
STX
DC2
3
Left
F3
ETX
DC3
4
Right
F4
EOT
DC4
5
PgUp
F5
ENQ
NAK
6
PgDn
F6
ACK
SYN
F7
BEL
ETB
F8
BS
CAN
7
8
Bs
9
Tab
A
F9
HT
EM
F10
LF
SUB
ESC
B
Home
Esc
VT
C
End
F11
FF
FS
D
Enter
F12
CR
GS
E
Insert
Ctrl+
SO
RS
F
Delete
Alt+
SI
US
L
H
2
3
4
0
SP
0
@
1
!
1
A
2
“
2
B
R
b
r
3
#
3
C
S
c
s
4
$
4
D
T
d
t
5
%
5
E
U
e
u
6
&
6
F
V
f
v
7
‘
7
G
W
g
w
8
(
8
H
X
h
x
9
)
9
I
Y
i
y
A
★
:
J
Z
j
z
B
+
;
K
[
k
﹛
C
,
<
L
\
l
︱
D
-
=
M
]
m
﹜
E
.
>
N
^
n
〜
F
/
?
O
_
o
DEL
103
5
6
7
P
`
p
Q
a
q
Parameter Setting List
Program
Barcode standard parameter setting list
If you wish to display the current configuration of your
AS-8150/ 8250 (REV.B) , scanner over the host
terminal/computer, scan the Barcode standard parameter
setting list bar code.
Unique parameter list
If you wish to display the unique parameter setting list, scan
the unique parameter list bar code
System parameter setting list
If you wish to display the product information and revision
number for your AS-8110/8120/8150/8250/8310/8312
scanner over the host terminal/computer, scan the System
parameter setting list bar code.
String setting list
If you wish to display the string
format list, scan the String setting list bar code.
104
Exit
Query Datamagic Setting
Program
Firmware version list
If you wish to display the Datamagic setting , scan
the “Query Datamagic Setting ” barcode.
Exit
Query present scanner firmware version
Program
Firmware version list
If you wish to display the firmware version, scan
the “Firmware version list” barcode.
Exit
105
Reset scanner to factory default settings
Program
WARNING: Default value initialization
If you wish to return the AS-8150/ 8250 (REV.B) to all the
factory default settings, scan the Default value initialization
bar code.
106
0
A
1
B
2
C
3
D
4
E
5
F
6
7
8
Finish
9
107