Report No: L111602301 Date: 11/14/2016 11/9/16 11/10/16

Report No: L111602301
Date: 11/14/2016
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
NVLAP LAB CODE 200927-0
L111602301
Report No:
Report Prepared For:
Model Number:
Test:
Revolution Lighting Technologies
4139 Guardian St. Simi Valley, CA 93063
128010-123
Electrical and Photometric tests
Standards Used: Appropriate part or all test guidelines were used for test performed:
IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products
ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products
ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment
Description of Sample:
Client submitted the sample. Catalog number is 128010-123. Received in working and
undamaged condition. No modifications were necessary.
Testing Condition:
Fixture is tested with no special conditions.
Sample Arrival Date:
11/9/16
Date of Tests:
11/10/16
Seasoning of Sample:
No seasoning was performed in accordance with IESNA LM-79.
-
11/14/16
Equipment List
Equipment Used
Chroma Programmable AC Source
Yokogawa Digital Power Meter
Xitron Power Analyzer
ITECH DC Power Supply
Fluke Digital Thermometer
LLI Type C Goniophotometer System
LLI 2M Sphere
LLI Spectroradiometer
Model No
Stock No
Calibration Due Date
61604
WT210
2503AH
IT6122
52k/J
RMG-C-MKII
2MR97
SPR-3000
PS-AC02
MT-EL06-S1
MT-EL01
PSDC-03-S1
MT-TP02-GC
CD-LL04-GC
CD-SN03-S2
MT-SC01-S2
-11/18/16
11/30/16
11/17/16
11/24/16
--Before Use
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 1 of 4
Report No: L111602301
Date: 11/14/2016
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
NVLAP LAB CODE 200927-0
Test Summary
Manufacturer:
Model Number:
Driver Model Number:
Total Lumens:
Input Voltage (VAC/60Hz):
Input Current (Amp):
Input Power (W):
Input Power Factor:
Current ATHD @ 120V(%):
Current ATHD @ 277V(%):
Efficacy:
Color Rendering Index (CRI):
Correlated Color Temperature (K):
Chromaticity Coordinate x:
Chromaticity Coordinate y:
Ambient Temperature (oC):
Stabilization Time (Hours):
Total Operating Time (Hours):
Off State Power(W):
Revolution Lighting Technologies
128010-123
LETRON LP0240-1450
9343.38
277.00
0.26
65.33
0.91
N/A
19%
143
83
4051
0.3808
0.3852
25.0
0:30
1:00
0.00
FIG. 1 LUMINAIRE
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 2 of 4
Report No: L111602301
Date: 11/14/2016
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
Percent Output
NVLAP LAB CODE 200927-0
Spectral Power
1.0
0.8
0.6
0.4
0.2
0.0
380
Wavelength
W/m2nm
380
390
400
410
420
430
0.0010
0.0011
0.0017
0.0050
0.0241
0.0994
CRI & CCT
x
0.3808
y
0.3852
u'
0.2220
v'
0.5053
CRI
83.40
CCT
4051
Duv
0.00381
R Values
R1
81.37
R2
88.65
R3
94.31
R4
82.00
R5
80.64
R6
83.70
R7
88.38
R8
67.80
R9
15.43
R10
72.82
R11
80.36
R12
56.81
R13
83.06
R14
96.61
430
440
450
460
470
480
490
500
480
530
0.3241
0.9132
0.6758
0.3837
0.2494
0.3114
0.4348
510
520
530
540
550
560
570
580
Wavelength(nm)
0.5464
0.6132
0.6603
0.7074
0.7513
0.7895
0.8217
580
590
600
610
620
630
640
630
680
0.8476
0.8623
0.8575
0.8268
0.7671
0.6842
0.5925
650
660
670
680
690
700
710
730
0.4976
0.4049
0.3196
0.2475
0.1881
0.1415
0.1058
780
720
730
740
750
760
770
780
0.0788
0.0581
0.0431
0.0322
0.0240
0.0180
0.0157
CIE 1931 Chromaticity Diagram
Y 0.9
520
0.8
530
540
510
0.7
550
560
0.6
570
500
0.5
580
590
0.4
600
0.3808, 0.3852
0.3
610
620
630
640
650
700
490
0.2
480
0.1
470
460
0
0
0.1
440
430
380
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
X
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 3 of 4
Report No: L111602301
Date: 11/14/2016
8165 E Kaiser Blvd. Anaheim, CA 92808
p. 714.282.2270
f. 714.676.5558
NVLAP LAB CODE 200927-0
Test Methods
Photometric Measurements - Goniophotometer
A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each
angle of distribution as defined by IESNA for the appropriate fixture type.
Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the
fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins
and longer as necessary for the sample to achieve stabilization.
Electrical measurements are measured using the listed equipment.
Spectral Measurements - Integrating Sphere
A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to
measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each
sample.
Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the
fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins
and longer as necessary for the sample to achieve stabilization.
Electrical measurements are measured using the listed equipment.
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST
or any agency of Federal Government.
Report Prepared by :
Keyur Patel
Test Report Released by:
Test Report Reviewed by:
Jeff Ahn
Engineering Manager
Steve Kang
Quality Assurance
*Attached are photometric data reports. Total number of pages: 9
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 4 of 4
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L111602301.IES
DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-2002
[TEST] L111602301
[TESTLAB] LIGHT LABORATORY, INC.
[ISSUEDATE] 11/14/2016
[MANUFAC] REVOLUTION LIGHTING TECHNOLOGIES
[LUMCAT] 128010-123
[LUMINAIRE] 64W ECO LINEAR HIGH BAY 4000K MEDIUM OPTIC
[BALLASTCAT] LETRON LP0240-1450
[LAMPPOSITION] 0,0
[LAMPCAT] N/A
[OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND
[MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS.
[INPUT] 277VAC, 65.33W
[TEST PROCEDURE] IESNA:LM-79-08
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criterion (0-180)
Spacing Criterion (90-270)
Spacing Criterion (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
N.A. (absolute)
N.A. (absolute)
9343
N.A.
143
65.33
1.00
Direct
1.10
1.06
1.18
Rectangular
1.92 ft
1.06 ft
0.00 ft
LUMINANCE DATA (cd/sq.m)
Angle In
Degrees
Average
0-Deg
Average
45-Deg
Average
90-Deg
45
55
65
75
85
13779
5896
3238
2450
2971
18069
8558
3613
1776
2728
13750
5408
2288
1205
2728
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L111602301.IES
CANDELA TABULATION
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
5797
5898
5968
5831
5363
4722
4033
3352
2627
1844
1130
640
406
259
172
120
79
49
0
22.5
5797
5889
5979
5864
5462
4880
4236
3578
2868
2090
1334
758
443
270
183
121
71
44
0
45.0
5797
5866
5939
5829
5474
4970
4420
3822
3167
2418
1610
929
522
289
168
87
52
45
0
67.5
5797
5858
5879
5696
5244
4675
4091
3497
2849
2088
1298
710
404
221
109
62
52
45
0
90.0
5797
5835
5827
5607
5105
4499
3890
3298
2644
1840
1075
587
355
183
98
59
52
45
0
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L111602301.IES
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-20
0-30
0-40
0-60
0-80
0-90
10-90
20-40
20-50
40-70
60-80
70-80
80-90
90-110
90-120
90-130
90-150
90-180
110-180
0-180
2172.75
4369.99
6582.37
8931.66
9302.36
9343.38
8782.02
4409.62
6029.68
2617.48
370.70
102.51
41.02
0.00
0.00
0.00
0.00
0.00
0.00
9343.38
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
23.30
46.80
70.40
95.60
99.60
100.00
94.00
47.20
64.50
28.00
4.00
1.10
0.40
0.00
0.00
0.00
0.00
0.00
0.00
100.00
Total Luminaire Efficiency = N.A.%
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
561.36
1611.38
2197.25
2212.38
1620.06
729.23
268.19
102.51
41.02
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L111602301.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
0
1
2
3
4
5
6
7
8
9
10
119 119 119 119
112 108 105 103
105 99 93 89
98 90 83 78
91 82 75 70
85 75 68 62
80 69 61 56
75 63 56 51
70 59 52 47
66 55 48 43
62 51 44 39
116 116 116 116
109 106 103 101
102 97 92 88
95 88 82 78
89 81 74 69
83 74 67 62
78 68 61 56
73 63 56 51
69 58 51 46
65 54 47 43
61 50 44 39
111 111 111
102 100 98
93 90 86
85 80 76
78 73 68
72 66 61
66 60 56
61 55 51
57 51 46
53 47 43
49 43 39
106 106 106
98 97 95
90 87 84
83 79 75
76 71 67
70 65 61
65 59 55
60 54 50
56 50 46
52 46 42
49 43 39
102 102 102
95 93 92
87 85 83
80 77 74
74 70 67
68 64 60
63 59 55
59 54 50
55 50 46
51 46 42
48 43 39
100
90
81
72
65
59
53
48
44
41
37
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 4
IES INDOOR REPORT
PHOTOMETRIC FILENAME : L111602301.IES
POLAR GRAPH
5979
4484
2990
2
1495
1
Maximum Candela = 5979 Located At Horizontal Angle = 22.5, Vertical Angle = 10
# 1 - Vertical Plane Through Horizontal Angles (22.5 - 202.5) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (10) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 5
Download PDF
Similar pages