Hybrid Fiber Cable, 12/18 AWG - EFB

Hybrid Fiber Cable,
12/18 AWG
PFC-0112
PFC-0118
H/W Version: 1
LevelOne Composite Copper/Fiber cables incorporate
high bandwidth optical fibers with insulated stranded
copper TFFN or THWN conductors. A wide variety of
design options are available including; conductors
ranging from 12 AWG to 18 AWG. A key application of
these cables is to extend the distance that powered
devices can be installed from the power source
1
in Power over Ethernet (PoE) installations. Proper
conductor size selection can increase this distance
to several thousand feet. The powered device could
be an IP camera, a wireless access point, or other
building automation device located in an area where
an electrical outlet is not readily available.
1. Fiber plug
2. Power plug
2
Related Prodoucts
PFE-1001T
PoE Extender over Hybrid Fiber, Transmitter, 65W
PFE-1101T
PoE Extender over Hybrid Fiber, Transmitter, 120
Fiber/Power Distance / PoE Output Table
Mdoel No
PFE-1001T
PFE-1001T
PFE-1101T
PFE-1101T
2
Hybrid Cable
PFC-0112
PFC-0118
PFC-0112
PFC-0118
Conductor Gauge
12 AWG
18 AWG
12 AWG
18 AWG
450M
50W
40W
60W
50W
700M
45W
20W
55W
28W
1KM
40W
10W
50W
18W
2KM
20W
28W
-
www.level1.com I one world_one brand_one level_
Antenna
Technical Specifications
PFC-0012
CONSTRUCTION CHARACTERISTICS
Fiber optic type: OM1 62.5/125
Type of cable: Tight buffer
Outer sheath: Fire-retardant PVC
Sheath colour: Black
Conductor material: Bare copper
Number of conductors: 2
Connector type: LC Duplex & M8
DIMENSIONAL CHARACTERISTICS
Tube diameter: 2mm
Number of optical fibres: 2
Nominal outer diameter: 0.37in
Nominal outer diameter: 9.4mm
Approximate weight: 93lb/kft
Approximate weight: 138kg/km
Conductor cross-section (AWG): 12
ELECTRICAL CHARACTERISTICS
Max. DC resistance of the conductor at 20°C: 1.65Ohm/kft
Max. DC resistance of the conductor at 20°C: 5.41Ohm/km
TRANSMISSION CHARACTERISTICS
Optical performance: CB (62.5/125 Standard, OM1)
Attenuation, max. 850 nm (cabled): 3.5dB/km
Attenuation, max. 1300 nm (cabled): 1.0dB/km
MECHANICAL CHARACTERISTICS
Maximum installation tension: 300lb
Maximum installation tension: 1335.0N
Max. Load. Long Term (lbs): 90.0lb
Max. Load. Long Term: 400.0N
Impacts per TIA/EIA FOTP-25: 2 at 5.88 N-m
Crush resistance per TIA/EIA FOTP-41: 220N/cm
Cable flexibility per TIA/EIA FOTP-104: 500 cycles
USAGE CHARACTERISTICS
Minimum Bending Radius - Install: 5.6in
Operating temperature, range: -40 .. 85°C
Ambient installation temperature, range: -10 .. 70°C
Storage temperature, range: -40 .. 85°C
Field of application: Indoor, Outdoor
PFC-0018
CONSTRUCTION CHARACTERISTICS
Fiber optic type: OM1 62.5/125
Type of cable: Tight buffer
Outer sheath: Fire-retardant PVC
Sheath colour: Black
Conductor material: Bare copper
Number of conductors: 2
Connector type: LC Duplex & M8
DIMENSIONAL CHARACTERISTICS
Tube diameter: 2mm
Number of optical fibres: 2
Nominal outer diameter: 0.32in
Nominal outer diameter: 8.1mm
Approximate weight: 49lb/kft
Approximate weight: 72kg/km
Conductor cross-section (AWG): 18
ELECTRICAL CHARACTERISTICS
Max. DC resistance of the conductor at 20°C: 6.66Ohm/kft
Max. DC resistance of the conductor at 20°C: 21.9Ohm/km
TRANSMISSION CHARACTERISTICS
Optical performance: CB (62.5/125 Standard, OM1)
Attenuation, max. 850 nm (cabled): 3.5dB/km
Attenuation, max. 1300 nm (cabled): 1.0dB/km
MECHANICAL CHARACTERISTICS
Maximum installation tension: 150lb
Maximum installation tension: 668.0N
Max. Load. Long Term (lbs): 45.0lb
Max. Load. Long Term: 200.0N
Impacts per TIA/EIA FOTP-25: 2 at 5.88 N-m
Crush resistance per TIA/EIA FOTP-41: 220N/cm
Cable flexibility per TIA/EIA FOTP-104: 500 cycles
USAGE CHARACTERISTICS
Minimum Bend Radius - Install: 12.2cm
Operating temperature, range: -40 .. 85°C
Ambient installation temperature, range: -10 .. 70°C
Storage temperature, range: -40 .. 85°C
Field of application: Indoor, Outdoor
Order Information
PFC-0112 / PFC-0118: Hybrid Fiber Cable, 12/18 AWG
Package Contents
PFC-0112 / PFC-0118
All mentioned brand names are registered trademarks and property of their owners. Technical specifications are subject to change without notice.
© Copyright Digital Data Communications GmbH. All Rights Reserved.
3
Download PDF