ATS48C41Q
Product data sheet
Characteristics
soft starter for asynchronous motor - ATS48 - 388
A - 230..415 V - 90..315 KW
Range of product
Altistart 48
Product or component type
Soft starter
Product destination
Asynchronous motors
Product specific application
Heavy duty industry and pumps
Device short name
ATS48
[Us] rated supply voltage
230...415 V (- 15...10 %)
Motor power kW
90 kW at 230 V (connection in the motor supply line) for severe applications
110 kW at 230 V (connection in the motor supply line) for standard applications
160 kW at 230 V (connection to the motor delta terminals) for severe applications
160 kW at 400 V (connection in the motor supply line) for severe applications
220 kW at 230 V (connection to the motor delta terminals) for standard applications
220 kW at 400 V (connection in the motor supply line) for standard applications
250 kW at 400 V (connection to the motor delta terminals) for severe applications
315 kW at 400 V (connection to the motor delta terminals) for standard applications
Power dissipation in W
For severe applications 1017 W
For standard applications 1339 W
Utilisation category
AC-53A
Type of start
Start with torque control (current limited to 5 In)
IcL starter rating
320 A (connection in the motor supply line) for severe applications
554 A (connection to the motor delta terminals) for severe applications
710 A (connection to the motor delta terminals) for standard applications
410 A (connection in the motor supply line) for standard applications
IP degree of protection
IP00
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Complementary
Assembly style
With heat sink
Function available
External bypass (optional)
Supply voltage limits
195...456 V
Supply frequency
50...60 Hz (- 5...5 %)
Network frequency
47.5...63 Hz
Device connection
In the motor supply line
To the motor delta terminals
Factory setting current
388 A
[Uc] control circuit voltage
220 - 15 % to 415 + 10 %, 50/60 Hz
Control circuit consumption
80 W
Feb 19, 2018
1
Discrete output number
2
Discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
Output absolute accuracy precision
+/- 5 %
Minimum switching current
Relay outputs 10 mA at 6 V DC
Maximum switching current
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms
Discrete input number
5
Discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
Discrete input voltage
24 V (<= 30 V)
Discrete input logic
Positive logic (Stop, Run, LI3, LI4) state 0 < 5 V and <= 2 mA, state 1 > 11 V and >= 5 mA
Supply inrush current
Adjustable 0.4...1.3 Icl
Analogue output type
(AO) current output 0-20 mA or 4-20 mA <= 500 Ohm
Communication port protocol
Modbus
Connector type
1 RJ45
Communication data link
Serial
Physical interface
RS485 multidrop
Transmission rate
4800, 9600 or 19200 bps
Installed device
31
Protection type
Phase failure (line)
Thermal protection (motor)
Thermal protection (starter)
Marking
CE
Type of cooling
Forced convection
Operating position
Vertical +/- 10 degree
Height
670 mm
Width
400 mm
Depth
300 mm
Product weight
51.4 kg
Power range
55...100 kW at 200...240 V 3 phases
110...220 kW at 380...440 V 3 phases
110...220 kW at 200...240 V 3 phases
250...500 kW at 380...440 V 3 phases
Motor starter type
Soft starter
Environment
Electromagnetic compatibility
Conducted and radiated emissions conforming to IEC 60947-4-2 level A
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Electrostatic discharge conforming to IEC 61000-4-2 level 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3
Voltage/Current impulse conforming to IEC 61000-4-5 level 3
Standards
EN/IEC 60947-4-2
Product certifications
CCC
CSA
C-Tick
DNV
GOST
NOM 117
SEPRO
TCF
UL
Vibration resistance
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
2
Noise level
55 dB
Pollution degree
Level 3 conforming to IEC 60664-1
Relative humidity
0...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient air temperature for operation
-10...40 °C without derating
> 40...60 °C with current derating of 2 % per °C
Ambient air temperature for storage
-25...70 °C
Operating altitude
<= 1000 m without derating
> 1000...2000 m with current derating of 2.2 % per additional 100 m
Contractual warranty
Warranty period
18 months
3
Product data sheet
Dimensions Drawings
Dimensions
(1) Right View
(2) Front View
4
ATS48C41Q
Product data sheet
Mounting and Clearance
ATS48C41Q
Clearance
5
ATS48C41Q
Product data sheet
Motor Starter BOM
Our Proposal: Circuit Breaker + Contactor + Soft starter for Motor Power from 90 to 220 kW and 230 to 400 VAC
Motor power
ICU
(kW)
(kA)
90 kW for 230 V
85
110 kW for 230 V
160 kW for 400 V
220 kW for 400 V
Breaker
Contactor (*)
Instantaneous auxiliary contacts
Motor Starter
LV432748
LC1F330P7
LADN22
ATS48C41Q
LV432948
LC1F400P7
LADN22
ATS48C41Q
LV432748
LC1F330P7
LADN22
ATS48C41Q
LV432948
LC1F400P7
LADN22
ATS48C41Q
85
36
36
Non contractual pictures.
Motor power
Coil voltage
kW
VDC
24
90 kW for 230 V
LC1F330 ..
BD
160 kW for 400 V
LC1F330 ..
110 kW for 230 V
220 kW for 400 V
48
110
125
220
230
Other
ED
FD
GD
MD
MD
Complete
Offer
BD
ED
FD
GD
MD
MD
Complete
Offer
LC1F400 ..
-
ED
FD
GD
MD
-
Complete
Offer
LC1F400 ..
-
ED
FD
GD
MD
-
Complete
Offer
(*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer.
Motor power
Coil voltage
kW
VAC 40...400 Hz
24
48
110
110 kW for 230 V
LC1F400 ..
-
E7
F7
220 kW for 400 V
LC1F400 ..
-
E7
90 kW for 230 V
LC1F330 ..
-
160 kW for 400 V
LC1F330 ..
-
115
120
220
230
240
400
Other
FE7
G7
M7
P7
U7
V7
Complete
Offer
F7
FE7
G7
M7
P7
U7
V7
Complete
Offer
E7
F7
FE7
G7
M7
P7
U7
V7
Complete
Offer
E7
F7
FE7
G7
M7
P7
U7
V7
Complete
Offer
(**) You can select the breaker proposed or variants. Please consider examples hereafter or follow the link to the complete offer.
6
Motor power
ICU (kA)
Breaker with capacity level ICU (kA)
Breaker with capacity level ICU (kA)
Breaker with capacity level Other
kW
F
110 kW for 230 V
85
LV432948
100
LV432950
90
LV432949
Complete Offer
160 kW for 400 V
36
LV432748
70
LV432750
50
LV431752
Complete Offer
220 kW for 400 V
36
LV432948
70
LV432950
50
LV432949
Complete Offer
90 kW for 230 V
85
LV432748
100
LV432750
90
LV431752
Complete Offer
F
H
H
N
N
7