quick reference guide - Universal Security Instruments

QUICK REFERENCE GUIDE
Model MICN109
OPERATIONAL SUMMARY
AUDIBLE & VISUAL SIGNALS
CONDITION / RECOMMENDATION
POWER
GREEN LED
SMOKE
RED LED
GAS
BLUE LED
CO
RED LED
Silent
On and Blinks
Off approx
every 20
seconds
Off
Off
Off
Condition: AC power is present. DC power is present.
Recommendation: None
Silent
Off and Blinks
On approx
every 40
seconds
Off
Off
Off
Condition: Alarm is powered by battery backup. AC Power
is not present.
Recommendation: Check the breaker or fuse box for power.
If the breaker or fuse box looks normal, call a licensed
electrician for assistance.
3 beeps,
2 second pause,
3 beeps,
6 second pause,
4 beeps,
5 second pause,
1 beep
Turns off
when the
3 beeps start
Blinks On during
the cycle of
3 beeps and
turns off
Horn does not
sound when
other alarms
are active
or when
interconnected
alarm’s
test/reset
button is
pressed
*See below
Off
3 Beeps,
2 second pause,
repeat
Turns off
when the
3 beeps start
3 Beeps,
2 second pause,
repeat
HORN
Blinks On in Blinks On in sync Condition: The test/silence button has been pressed. The
sync with
with the cycle of test sequence lasts for approx. 20 seconds.
the 1 beep
4 beeps and
Recommendation: None
turns off
Off
Off
Condition: One or more alarms not responding to
interconnected alarm.
Recommendation: Press and hold the smoke alarm
Test/Silence button for at least 5 seconds. If still no alarm,
turn off AC Power at the circuit breaker or fuse box and
disconnect the alarm from the mounting bracket and make
sure the connector plug is securely attached on units that
did not alarm. If still no alarm, have a licensed electrician
make sure the yellow wire is not mistakenly or accidentally
connected to the white (neutral) wire.
Blinks On
approx. once
every second
Off
Off
Condition: Originating Smoke Alarm.
Recommendation: If hazard is identified, take all
precautions if an alarm sounds by calling an Emergency
Service and getting out of the home.
Turns off
when the
3 beeps start
Off
Off
Off
Condition: Non-originating Smoke Alarm.
Recommendation: Another interconnected smoke alarm
has sensed smoke, causing all interconnected units to
sound. If hazard is identified, take all precautions if an
alarm sounds by calling an Emergency Service and getting
out of the home.
4 Beeps,
5 second pause,
repeat
Turns off
when the
4 beeps start
Off
Off
Blinks On in
sync with
4 beeps
Condition: Originating CO Alarm.
Recommendation: If hazard is identified, take all
precautions if an alarm sounds by calling an Emergency
Service and getting out of the home.
4 Beeps,
5 second pause,
repeat
Turns off
when the
4 beeps start
Off
Off
Off
Condition: Non-originating CO Alarm.
Recommendation: An interconnected CO alarm has
sensed CO, causing all interconnected units to sound.
If hazard is identified, take all precautions if an alarm
sounds by calling an Emergency Service and getting
out of the home.
1 Beep,
2 second pause,
repeat
Turns off
when the
1 beep starts
Off
Blinks On
in sync
with the
1 beep
Off
Condition: Originating GAS Alarm.
Recommendation: If hazard is identified, take all
precautions if an alarm sounds by calling an Emergency
Service and getting out of the home.
1 Beep,
2 second pause,
repeat
Turns off
when the
1 beep starts
Off
Off
Off
Condition: Non-originating GAS Alarm.
Recommendation: An interconnected GAS alarm has
sensed GAS, causing all interconnected units to sound.
If hazard is identified, take all precautions if an alarm
sounds by calling an Emergency Service and getting out
of the home.
Horn sounds
when no
hazard is
present
Turns off
when the
beeps start
Off or Blinks
On approx.
once every
second
Off or Blinks
On in
sync with
the 1 beep
Off or Blinks
On in sync
with 4 beeps
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the
alarm imounted in the correct location (see User’s Manual).
Reset alarm as instructed below.
Blinks On
approx.
once every
second
Off
Off
Condition: Smoke alarm when cause of alarm is known
and poses no threat.
Recommendation: The smoke alarm Silence Feature can
be activated by pressing and releasing the Test/Silence
button on the initiating alarm while in alarm condition. Silence
mode will last for approx. 8-12 minutes (with the red LED
blinking on approx. every 10 seconds).
Off
Off
Blinks
On in sync
with 4 beeps
3 Beeps,
Turns Off when
2 second pause, the 3 beeps
repeat
start
4 Beeps,
5 second pause,
repeat
Turns off
when the
4 beeps start
Page 1
Page 16
Condition: CO alarm when cause of alarm is known and
poses no threat.
Recommendation: The CO alarm Silence Feature can be
activated by pressing and releasing the Test/CO Silence
button on the initiating alarm while in alarm condition. The
alarm will remain silent for approx. 5 minutes (with the red
LED blinking on approx. every 10 seconds), depending on
the level of CO detected. If CO levels drop below alarm
levels, the alarm will remain silent and return to normal
operation. If CO levels remain constant or increase, this
indicates a potentially dangerous situation and the horn
will sound again. Ventilate area.
OPERATIONAL SUMMARY (continued)
AUDIBLE & VISUAL SIGNALS
CONDITION / RECOMMENDATION
POWER
GREEN LED
SMOKE
RED LED
GAS
BLUE LED
CO
RED LED
Silent
(alarmed
previously)
On and Blinks
Off approx
every 20
seconds
Off or Blinks
On approx
every 5
seconds
until reset
Off or
Blinks On
approx.
every 5
seconds
until reset
Off or Blinks
On approx.
every 5
seconds until
reset
Condition: Previous alarm condition at unidentified source.
Recommendation: QUICK FIND® Alarm Origination - In an
interconnected system, it is difficult to determine which alarm
initiated the alarms to sound. The QUICK FIND® feature will
immediately allow you to locate the originating alarm (once
the alarms have stopped sounding). To initiate QUICK FIND®,
press and hold the test/silence button on any alarm until the test
sequence on this alarm begins. Release the test button. The
specific horn pattern/sequence is designated by the alarm type.
Once this test sequence ends, the originating alarm continues
to sound for approximately 60 seconds. In a non-interconnected
installation, it is necessary to test each alarm to determine the
originating alarm. Reset the originating alarm.
Horn has
stopped
sounding
On and Blinks
Off approx
every 20
seconds
Off and Blinks
On approx
every 5
seconds
until reset
Off
Off
Condition: Latching smoke LED indicator. The alarm has
previously detected smoke and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Horn has
stopped
sounding
On and Blinks
Off approx
every 20
seconds
Off
Off
Off and Blinks
On approx
every 5
seconds
until reset
Condition: Latching CO LED indicator. The alarm has
previously detected CO and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Horn has
stopped
sounding
On and Blinks
Off approx
every 20
seconds
Off
Off and Blinks
On approx
every 5
seconds
until reset
Off
Condition: Latching GAS LED indicator. The alarm has
previously detected GAS and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Silent
(alarmed
previously)
On and Blinks
Off approx
every 20
seconds
Off or Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset
Condition: Alarm needs to be reset due to abnormal
operation/previous alarms.
Recommendation: To reset the alarm, hold the Test/Silence
button for 10 seconds or until the blue LED turns on. This
will clear the alarm origination and latching LEDs. Reset
after each alarm event.
1 Chirp
approx.
every 40
seconds
On and Blinks
Off approx
every 20
seconds
Off
Off
Off
Condition: Low battery.
Recommendation: Check to make sure a battery is present
in the drawer, the battery activation pull tab has been
completely removed, battery polarity is correct and the battery
terminals are making contact with the smoke alarm contacts
in the battery drawer. If chirp continues, replace the 9V battery
(see User’s Manual for recommended battery types).
3 Chirps
approx.
every 20
seconds
On and Blinks
Off approx
every 20
seconds
Off
Off
Off
Condition: Sensor Trouble/Sensor End-of-Life Alarm.
Recommendation: Reset the alarm. If this does not clear
the problem, replace alarm.
2 Chirps
approx.
every 20
seconds
On and Blinks
Off approx
every 20
seconds
Off
Off
Off
Condition: Product End-of-Service Life Notification.
Recommendation: Replace the alarm immediately. The
product end-of-service life notification can be temporarily
silenced for a 10 hour period for up to 20 days. After 20
days, the warning cannot be silenced. The alarm should be
replaced immediately.
HORN
RESET INSTRUCTIONS: Press the Test/Silence button for 10 seconds, or until the blue LED turns on, and then release. This will clear the alarm
latching LED’s and clear the alarm origination. Be sure to RESET alarms after each alarm event.
QUICK FIND® Alarm Origination/Location Feature: The QUICK FIND® feature will allow you to immediately locate the originating alarm (the alarm
that triggered the other alarms), once the alarms have stopped sounding.
1.Press and hold the test/silence button on any alarm until the test sequence on this alarm begins. Release the test button. The specific horn pattern/
sequence is designated by the alarm type.
2.Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to locate the
originating alarm.
3.Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation.
NOTE: If you have any additional questions about the operation of your alarm, please contact our Customer Service Department at 1-800-390-4321,
and we will gladly assist you.
* During 120 volt operation On and Blinks Off approx. every 20 seconds.
During 9 volt (DC backup) operation, blinks On approx. every 40 seconds.
USI ELECTRIC. INC.
www.SmokeAlarms.com
1.800.390.4521
288-3482-11 (QRG)
(c)2013 Universal Security Instruments, Inc. 06/2016