Mr. Heater MHVFB30TBLP Manual

OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
UNVENTED LP-GAS FIRED ROOM HEATER
Plaque Heaters­
Blue Flame Heaters
MHVFRD20LPBT
MHVFBF20LPBT
(BLOWER INCLUDED)
(BLOWER INCLUDED)
MHVFRD20LPT
MHVFBF20LPT
(BLOWER SOLD SEPARATE)
(BLOWER SOLD SEPARATE)
MHVFRD30LPBT
MHVFBF30LPBT
(BLOWER INCLUDED)
(BLOWER INCLUDED)
MHVFRD30LPT
MHVFBF30TLPT
(BLOWER SOLD SEPARATE)
(BLOWER SOLD SEPARATE)
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.­
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Shut off gas supply
• Do not try to light any appliance
• Do not touch an electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion
and Ventilation section on page 4 of this manual.­
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual for correct installation and operational procedures. For assistance or additional
information consult a qualified installer, service agency, or gas supplier.­
This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with any other gas.­
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 · 800-251-0001
2017 - CB
WARNINGS
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or
service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion,
electrical shock, and carbon monoxide poisoning.­
•
WARNING: This appliance is equipped for propane
gas. Field conversion is not permitted.
•
WARNING: Do not use any accessory not
approved for use with this heater.­
WARNING: Any change to this heater or its
controls can be dangerous.­
•
•
•
•
Do not place clothing or other flammable material on or near the appliance.
Due to high temperatures, heater should be
kept out of traffic and away from furniture and
draperies.­
Surface of heater becomes very hot when
running. Keep children and adults away
from hot surfaces to avoid burns or clothing
ignition. Heater will remain hot for a time
after shutdown. Allow heater surfaces to cool
before handling.­
•
•
Young children should be carefully supervised
when they are in the same room with heater.­
Make sure grille guard is in place before
running heater. If screen or grille guard is
removed for servicing it must be replaced prior
to operating the heater.­
Keep the appliance area clear and free from
combustible materials, gasoline, and other
flammable vapors and liquids.­
Children and adults should be alerted to the
hazard of high surface temperature and should
stay away to avoid burns or clothing ignition.
Any safety screen or guard removed for
servicing an appliance must be replaced prior
to operating the heater
CONTENTS
WARNINGS.........................................................................2
SPECIFICATIONS..................................................................3
PRECAUTIONS.....................................................................3
IGNITION SYSTEM BATTERY INSTALLATION........................4
BLOWER FAN CONTROL SWITCH OPERATION.....................4
DETERMINING THE TYPE OF HEATER LOCATION SPACE......5
INSTALLATION....................................................................6
FASTENING HEATER TO WALL.............................................7
FLOOR MOUNTING AWAY FROM WALL..............................8
CONNECTING TO GAS SUPPLY............................................8
OPERATING YOUR HEATER................................................ 10
CLEANING AND MAINTENANCE........................................11
TROUBLESHOOTING......................................................... 14
EXPLODED-VIEW PARTS DRAWING.................................... 16
PARTS LIST........................................................................ 17
WARRANTY ..................................................................... 20
CAUTION:
Never connect heater directly
to the Propane supply. This heater requires
an external regulator (not supplied). Install
the external regulator between the heater and
Propane/LP supply.­
The installer must supply an external
regulator. The external regulator will reduce
the incoming gas pressure to between 11
and 14 inches of water. If you do not reduce
incoming gas pressure heater regulator
damage could occur. Install external regulator
with the vent pointing down. Pointing the
vent down protects it from freezing rain or
sleet.
SOCIAL MEDIA
In order to provide the best service possible Mr. Heater is now giving you
more ways to get in touch with us:
WEBSITE: Mr. Heater’s full line of product are now at:
WWW.MRHEATER.COM
FACEBOOK: Find us on Facebook
TWITTER: Find us on twitter
YouTube: There are now informational videos on YouTube.
Unvented LP-Gas Vent Free Room Heaters
2
Installation Instructions and Owner’s Manual
SPECIFICATIONS
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**
MODEL
MHVFRD20BT/
MHVFRD20T LP
MHVFRD30TB /
MHVFRD30T LP
MHVFBF20TB /
MHVFBF20T LP
­ HVFBF30TB /
M
MHVFBF30T LP
BTU (Available)­
18,000
30,000­
20,000
30,000­
Type of Gas­
LP-Gas Only­
LP-Gas Only­
LP-Gas Only­
LP-Gas Only­­
Ignition­
Battery ignitor (1-AA)­ Battery ignitor (1-AA)­ Battery ignitor (1-AA)­ Battery ignitor (1-AA)­
Pressure Regulator Setting­
10 Inches of Water­
10 Inches of Water­
10 Inches of Water­
10 Inches of Water­
Inlet Gas Pressure (Maximum)­
14 Inches of Water­
14 Inches of Water­
14 Inches of Water­
14 Inches of Water­
Inlet Gas Pressure (Minimum)­
11 Inches of Water­
11 Inches of Water­
11 Inches of Water­
11 Inches of Water­
Electrical Rating­/Blower
120V, 60Hz­, 1
120V, 60Hz­, 1
120V, 60Hz­, 1
120V, 60Hz­, 1
Thermostatic Control­
Yes
Yes­
Yes
Yes
Clearances: inches (mm)­
Top
36” (915cm)­
36” (915cm)­
36” (915cm)­
36” (915cm)­
Sides
10” (254cm)­
10” (254cm)­
10” (254cm)­
10” (254cm)­
Floor (min to top of carpet) 3” (76cm)­
3” (76cm)­
3” (76cm)­
3” (76cm)­
Fabric / flammable objects
36” (915cm)­
36” (915cm)­
36” (915cm)­
36” (915cm)­
PRECAUTIONS:
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
DANGER: Carbon monoxide poisoning may lead to
death.­
1. 20,000 BTU or 30,000 BTU may not be installed
in a bedroom or bathroom, or any place where a
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS)
safety shutoff system shuts down the heater if not
enough fresh air is available. See Fresh Air for
Combustion and Ventilation, pages 5 through 6.
WARNING: An unvented heater having an input
of more than 10,000 Btu/hr (2 931W) shall not be
installed in a bedroom or bathroom.
Carbon Monoxide Poisoning:
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and unplug heater and let cool before
servicing. Only a qualified service person should
service and repair heater.
6. Do not run heater:
Early signs of carbon monoxide poisoning resemble
the flu, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
• Where flammable liquids or vapors are used or stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner
or similar products, turn heater off. If heated the
vapors from these products may create a white
powder residue within burner box or on adjacent
walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to
inspect the room heater and to replace any part of
Unvented LP-Gas Vent Free Room Heaters
3
Installation Instructions and Owner’s Manual
Product Features
Fan Blower
Switch
FRESH AIR FOR COMBUSTION AND
VENTILATION
Ignitor Button
WARNING: This heater shall not be installed in a
room or space unless the required volume of indoor
combustion air is provided by the method described in
the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Read the following instructions to insure proper fresh air
for this and other fuel-burning appliances in your home.­
Control Knob
(located on back
of heater)
Burners
ESTABLISHING ADEQUATE VENTILATION
Grill
The following are excerpts from National Fuel Gas
Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for
Combustion and Ventilation. All spaces in homes fall
into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
This heater must not be installed in a confined space
or unusually tight construction unless provisions are
provided for adequate combustion and ventilation air.
The information on pages 4 through 6 will help you
classify your space and provide adequate ventilation.
Heater
Cabinet
Front Panel
Figure 1
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensor (ODS) safety shut off system. The ODS/pilot shuts
off the heater if there is not enough fresh air.
IGNITION SYSTEM / BATTERY INSTALLATION
– The heater is equipped with an electronic manual
ignitor. This system requires no matches, or other
source to light heater, but does require one AA battery
to operate ignitor. (AA Battery included).
Unusually Tight Construction
If your home meets all of the three following criteria you
must provide additional fresh air. See Ventilation Air
from Outdoors, page 6.
Unusually tight construction is defined as construction
where:
a.Walls and ceilings exposed to the outside
atmosphere have a continuous water vapor retarder
with a rating of one perm (6 x 10-11 kg per pa-sec-m2)
or less with openings gasketed or sealed and
b.Weather stripping has been added on operable
windows and doors, and
c. Caulking or sealants are applied to areas such
as joints around windows and door frames,
between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines,
and at other openings.
If your home does not meet all of the three criteria
above, see Determine the Type of Heater Location
Space, page 5.
To install or replace battery unscrew the ignitor cap
(red button), insert battery positive (+) terminal up
and replace cap.
(AA Battery included)
THERMOSTATIC CONTROL
These heaters have a control valve with a thermostat
sensing bulb. This results in the greatest heater comfort
and may result in lower bills.
BLOWER FAN CONTROL SWITCH OPERATION
These heaters also include an electrical blower. The
blower switch has three positions: MANUAL, OFF and
AUTO. In AUTO, the blower will turn on and off as the
heater cycles on and off. On MANUAL, the blower will run
continuously. To turn blower off, use the OFF position.
LOCAL CODES
Install and use heater with care.
Installation must conform to local codes or in the
absences of local codes, use the latest edition of
National Fuel Gas Code ANSI Z223.1/NFPA 54.
Confined Space and Unconfined Space
The National Fuel Gas Code, NFPA 54/ ANSI Z223.1
defines a confined space as a space whose volume is
less than 50 cubic feet per 1,000 Btu per hour (4.8 m3
per kW) of the aggregate input rating of all appliances
installed in that space, and an unconfined space as a
space whose volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8 m3 per kW) of the aggregate
input rating of all appliances installed in that space.
Rooms communicating directly with the space in which
the appliances are installed*, through openings not
furnished with doors, are considered a part of the
unconfined space.
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged, promptly inform dealer
where you bought heater.
Unvented LP-Gas Vent Free Room Heaters
4
Installation Instructions and Owner’s Manual
*Adjoining rooms are communication only if there
are door less passageways or ventilation grills
between them.
Air From Inside Building (Figure 2).
B.Vent room directly to the outdoors. See Ventilation
Air From Outdoors (Figure 3).
C.Install a lower Btu/hr heater if lower Btu/hr size
makes room unconfined.
If actual Btu/hr used is less than the maximum Btu/
hr the space can support, the space is an unconfined space. You will need no additional fresh air
ventilation.
DETERMINING THE TYPE OF HEATER
LOCATION SPACE:
Use this method to determine if you have a confined or
unconfined space.
Note: the space includes the room in which you
install heater plus any adjoining rooms with doorless
passageways or ventilation grills between the rooms.
1.Find the volume of the space by multiplying room
length x width x height.
Example: Space size 18ft (length) x 18ft. (width) x 8ft. (height) = 2592
If additional ventilation to adjoining room is supplied
with grills or openings, add the volume of these rooms
to the total volume of the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/hr the space can support.
Example: 2592 cu.ft. (volume of space) / 50 cu.ft. = 51.8 or 51,800 (maximum Btu/hr the space can support)
WARNING: If the area in which the heater may be
operated is smaller than defined as an unconfined
space or if the building is of unusually tight
construction, provide adequate combustion and
ventilation air by the methods described in the
National Fuel Gas Code, NFPA 54/ ANSI Z223.1,
Section 5.3 or applicable local codes.­
3.Add the Btu/hr of all the fuel-burning appliances
in the space such as, Vent–free heater, Gas water
heater, Gas furnace, Vented gas heater, Gas fireplace logs, and Other gas appliances*
*Do not include direct-vent gas appliances. Directvent draws combustion air from the outdoors and
vents to the outdoors.
Example: Gas water heater
40,000 Btu/hr
Vent Free Heater +
20,000 Btu/hr
Total
=60,000 Btu/hr
4.Compare the maximum Btu/hr the space can support
with the actual amount of Btu/hr used.
Example: 51,800 Btu/hr (maximum Btu/hr the space can support)
60,000 Btu/hr (Actual amount of Btu/hr used)
The space in the above example is a confined
space because the actual Btu/hr used is more than
the maximum Btu/hr the space can support.
You must provide additional fresh air. Your options
are as follows:
A.Rework worksheet, and the space of an adjoining
room. If the extra space provides an unconfined
space, remove door to adjoining room or add
ventilation grills between the rooms. See Ventilation
Unvented LP-Gas Vent Free Room Heaters
VENTILATION AIR
Ventilation from Inside Building
This fresh air would come from an adjoining unconfined
space. When ventilation to an adjoining unconfined
space, you must provide two permanent openings:
one within 12” of the ceiling and one within 12” of
the floor on the wall connecting the two spaces (see
options 1 & 2 of fig. 2). You can also remove door into
adjoining room (see option3, fig 2). Follow the National
Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3,
Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
12”
Ventilation
Gills into
Adjoining
Room Option 1
Or remove
door into
Adjoining
Room Option 3
Ventilation Gills into
Adjoining Room - Option 2
12”
Figure 2.
VENTILATION AIR
OUTLET AIR
VENTILATED
ATTIC
OUTLET
AIR
TO ATTIC
TO CRAWL
SPACE
INLET
AIR
VENTILATION CRAWL SPACE
Figure 3.
5
Installation Instructions and Owner’s Manual
*A CSA/AGA certified equipment shutoff valve with
1/8” NPT tap is an acceptable alternative to test gauge
connection. Purchase a CSA/AGA certified equipment
shutoff valve from your dealer.
WARNING: Rework worksheet, adding the space
of the adjoining unconfined space. The combined
space must have enough fresh air to supply all appliance in both spaces.­
LOCATING HEATER
Ventilation from Outdoors
This heater is designed to be mounted on the wall. The
heater can also be located on a non-combustible floor,
away from a wall by using the floor mounting stands
included with the heater. If installed on combustible
flooring such as carpeting, tile or other combustible
material other than wood flooring, the heater must be
placed on a wood panel the full width and depth of the
appliance.
For convenience and efficiency, install the heater:
If necessary provide extra fresh air by using ventilation
grills or ducts. Connect these items directly to the
outdoors or spaces open to the outdoors. These
include attics* and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3,
Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
*IMPORTANT: Do not provide openings for inlet or
outlet into attic. If attic has a thermostat-controlled
power vent, heated air entering the attic will activate
the power vent.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Fresh Air
for Combustion and Ventilation, pages 5 through 6.­
• Where there is easy access for operation,
inspection, and service
• In the coldest part of the room.
• If planning to use fan, locate heater near an
electrical outlet.
CAUTION: If you install the heater in a home garage:­
Heater pilot and burner must be at least 18 inches
above floor­. Locate heater where moving vehicle will
not hit it.­
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
covering or operating heater where impurities (such
as tobacco smoke, aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) are present in the air may
discolor walls.­
WARNING: Never install the heater:­
• In a bedroom (RD20LPT, RD30LPT, BF20LPT
or BF30LPT)­
• In a recreational vehicle­·.
INSTALLATION
WARNING: Any change to this heater or its
controls can be dangerous.
NOTICE: This appliance is intended for supplemental
heating. Use this heater along with your primary heating
system. Do not install this heater as your primary heat
source. If you have a central heating system, you may
run system’s circulating blower while using heater. This
will help circulate the heat throughout the house. In the
event of a power outage, you can use this heater as
your primary heat source for the duration of the outage.­
WARNING: A qualified service person must install
heater. Follow all local codes.­
CHECK GAS TYPE
• Where curtains, furniture, clothing, or other
Use only LP-gas. If your gas supply is not LP-gas, do
not install heater. Call dealer where you bought heater
for proper type heater.
flammable objects are less than 36 inches from
the front, top, or sides of the heater.­
• As a fireplace insert­
• In high-traffic areas­
• In windy or drafty areas­
WARNING: Heater must be mounted to maintain
the minimum clearances shown in Figure 4. If
possible, provide greater clearances from the floor,
ceiling, and joining walls.­
THIS INSTALLATION REQUIRES:
Before installing heater, make sure you have the items
listed below:
•
•
•
•
•
•
•
•
Piping (check local codes)
Sealant (resistant to LP_Gas)
Equipment shutoff valve*
Ground joint union
Test gauge connection*
Sediment trap
Tee joint
Pipe wrench
Unvented LP-Gas Vent Free Room Heaters
6
Installation Instructions and Owner’s Manual
Attaching to Wall Stud:
This way is the best providing the strongest mounting in
wood frame houses.
10”(254cm)
from sides
Left
Side
Attaching to Wall Anchor:
36” (915cm)
min. from ceiling
This way allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls
(concrete or masonry).
Decide which way best suits your needs. Either method
will provide a secure hold for the mounting bracket.
Right
Side
1. Tape mounting bracket to wall where heater
will be located. Make sure mounting bracket is
level. For wall stud mounting locate one end of
the mounting bracket over a wall stud.
WARNING: Maintain minimum clearances shown in
figure 7. If you can, provide greater clearances from
the floor and joining wall.­
2. Mark screw locations on wall (see figure 7).
3. Remove tape and mount bracket from wall.
Floor
3” min. to top surface of carpet, tile
or other combustible material
Figure 4
FASTENING HEATER TO WALL
Mounting Bracket
SEE CLEARANCE
SPECIFICATIONS ON PG. 3
Adjoining Wall
The mounting bracket in located on the back panel of
heater (see figure 5). It has been taped there for shipping. Remove mounting bracket from back panel.
16” (Lg)
12-9/64” (Sm)
18” Min.
Mark mounting hole locations
and drill holes where indicated.
Allow for minimum clearances
Mounting
Bracket
Figure 5
Figure 7
Attaching to Wall Stud:
Removing Front Panel of Heater
1. Remove (4) screws total there are (2) screws
on either side of the heater (Figure 6).
2. Pull the front panel and back panel apart.
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64” drill
bit.
2. Place mounting bracket onto wall. Line up
holes on each end of bracket with hole drilled in
wall.
3. Insert mounting screws through bracket and
into wall studs.
4. Tighten screws until mounting bracket is firmly
fastened to wall studs.
(2) Screws
(2) Screws
Attaching to Wall using Anchor:
Figure 6
For attaching mounting bracket to hollow walls (wall areas
between studs) or solid walls (concrete or masonry)
Note: Wall anchors, mounting screws, and spacer
are in hardware package. The hardware package is
provided with heater.
1. Drill holes at marked locations using 5/16” drill
bit. For solid walls (concrete or masonry), drill
at least 1” deep.
Attaching Mounting Bracket to Wall
Use holes on each end of mounting bracket to attach
bracket to wall. These holes are 16 inches apart. Attach
mounting bracket to wall in one of two following ways.
1. Attach to wall studs
2. Attach to wall anchor
Unvented LP-Gas Vent Free Room Heaters
7
Installation Instructions and Owner’s Manual
2. Fold wall anchor as shown in figure 8 below.
If installing bottom mounting screw into wall
stud, drill holes at marked locations using 9/64”
drill bit.
5. Re-place heater onto mounting bracket.
6. Place spacers between bottom mounting holes
and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With the
other hand, insert mounting screw through
bottom mounting hole and spacer. Place tip of
screw in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly
secured to wall. Do not over tighten.
Note: Do not re-place front panel at this time.
Replace front panel after making gas connections
and checking for leaks.
Figure 8.
3. Insert wall anchor (wings first) into hole. Tap
anchor flush to wall.
4. For thin walls (1/2” or less) insert red key into
wall anchor.
5. Place mounting bracket onto wall. Line up
holes on each end of bracket with wall anchors.
6. Insert mounting screws through bracket and
into wall anchors.
7. Tighten screws until mounting bracket is firmly
fastened to wall.
FLOOR MOUNTING AWAY FROM WALL:
Installing Support Feet (see figure 11)
Placing Heater on Mounting Bracket
1. Locate two horizontal slots on back pane of
heater (see figure 9).
2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting
bracket.
Horizontal Slots
Figure 11
1. Lay heater onto table on its back with bottom
edge overhanging table edge.
2. Securely attach feet to bottom of heater using
2 – self-tapping screws each.
Mounting Bracket
mounted to wall
Note: Feet should have long end going out the
front of heater, and the edge coinciding with side of
heater. If feet overhang side of the heater, switch
leg location.
3. Place heater on non-combustible surface (see
Locating Heater above) before proceeding
with gas connection. If this will be a permanent
location, heater may be locked into position
using anchoring holes in mounting feet.
Note: Use of floor mounting feet will require you to
use a 3/8 NPT street elbow to make gas connection.
Figure 9.
Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These
holes are near bottom on back panel of heater
(see figure 10).
Screw
hole
Screw
hole
CONNECTING TO GAS SUPPLY
Figure 10
WARNING: A qualified service person must connect
heater to gas supply. Follow all local codes.­
2. Mark screws locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screw into hollow
or solid wall, install wall anchors. Follow steps 1
through 4 under Attaching to Wall using Anchor.
Unvented LP-Gas Vent Free Room Heaters
WARNING: This appliance requires a 3/8” NPT
(National Pipe Thread) inlet connection to the
pressure regulator. Use of floor mounting feet will
require you to use a 3/8 NPT street elbow to make
gas connection.­
8
Installation Instructions and Owner’s Manual
CAUTION: Never connect heater directly to the Propane
supply. This heater requires an external regulator (not
supplied). Install the external regulator between the
heater and Propane/LP supply.­
IMPORTANT: The installer must supply an external
regulator. The external regulator will reduce the
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incoming gas
pressure heater regulator damage could occur.
Install external regulator with the vent pointing
down. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of larger
enough diameter to allow proper gas volume to heater.
If pipe is too small, undue loss of pressure will occur.­
IMPORTANT: Hold pressure regulator with wrench
when connecting it to gas piping and/or fittings.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections for
leaks after installing or servicing. Correct all leaks
at once.­
WARNING: Never use an open flame to check for
a gas leak. Apply a mixture of liquid soap and water
to all joints. Bubbles forming show a leak. Correct
all leaks at once.­
PRESSURE TESTING GAS SUPPLY PIPING
SYSTEM
Test pressure in Excess of ½ psig (3.5kPa)
1. Disconnect appliance with its appliance main
gas valve (control valve) and equipment shutoff
valve from gas supply piping system. Pressures
in excess of ½ psig will damage heater
regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either using
compressed air or opening main gas valve on
or near gas meter.
4. Check all connections and joints in gas supply
piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Depressurize and relieve pressure in supply
piping system.
7. Reconnect heater and equipment shutoff valve
to gas supply.
8. Reconnected fittings must be checked for leaks
in next section.
Installation must include an equipment shutoff valve,
union and plugged 1/8” NPT tap. Locate NPT tap within
reach of test gauge hookup. NPT tap must be upstream
from heater (see figure 12).
HEATER CABINET
Pressure
Regulator
3/8” NPT Pipe Nipple
Ground Joint Union
Nipple
Shutoff Valve
Nipple
1/8” NPT Plug Tap
Test Gauge
Connection
Tee Joint
Fuel line from
Regulated LP Tank
(11”W.C to 14” WC Pressure)
Nipple
Reducer Bushing
to 1/8” NPT
Tee Joint
3” minimum
Nipple
Sediment
Trap
Cap
Test Pressure Equal To or Less Than ½ psig (3.5 kPa)
FIGURE 12
1. Close equipment shutoff valve (see figure 13).
2. Pressurize supply piping system by either using
compressed air or opening main gas valve on
or near gas meter.
3. Check all joints from the gas meter to
equipment shutoff valve (see figure 14). Apply
mixture of liquid soap and water to gas joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
5. Depressurize and relieve pressure from supply
piping system.
*A CSA/AGA certified equipment shutoff valve with
1/8” NPT tap is an acceptable alternative to test gauge
connection. Purchase the CSA/AGA certified equipment
shutoff valve from your dealer.
IMPORTANT: Install an equipment shutoff valve in an
accessible location. The equipment shutoff valve is for
turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will
prevent excess sealant from going into pipe. Excess
sealant in pipe could result in clogged heater fuel train.
CAUTION: Use pipe joint sealant that is resistant to LP-Gas.­
Install sediment trap in supply line as shown in figure
12. Locate sediment trap where it is within reach
for cleaning. A sediment trap traps moisture and
contaminants. This keeps them from going into heater.
If sediment trap is not installed or is installed improperly,
heater may not run correctly.
Unvented LP-Gas Vent Free Room Heaters
9
Installation Instructions and Owner’s Manual
Pressure Testing Heater Gas Connections:
1. The appliance and its appliance main gas valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of ½
psi (3.5 kPa). The appliance must be isolated
from the gas supply piping system by closing
its equipment shutoff valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
2. Make sure control knob of heater is in OFF
position.
3. Open equipment shutoff valve (see figure 13).
4. Open main gas valve on or near gas meter.
5. Check all joints from equipment shutoff valve
to control valve (see figure 14). Apply mixture
of liquid soap and water to gas joints. Bubbles
forming show a leak.
6. Correct all leaks at once.
7. Light heater (see Operating Your Heater, pages
10 and 11. Check the rest of the internal joints
for leaks.
8. Turn off heater (see To Turn OFF Gas to
Appliance, page 11.
9. Replace lower front panel.
Caution: Label all wires prior to
disconnection when
servicing controls.
Wiring errors can cause
improper and dangerous
operation. Verify proper
operation after servicing.
Figure 15
ELECTRICAL WIRING DIAGRAM:
If any original wiring as supplied with the heater must
be replaced, it must be replaced with type AWG 105oC
wire or its equivalent except as indicated.
WARNING: Electrical Grounding Instructions: This
heater is equipped with a three-prong (grounding)
plug for your protection against shock hazard and
should be plugged into a properly grounded threeprong receptacle.­
OPERATING YOUR HEATER
Open
FOR YOUR SAFETY READ BEFORE LIGHTING
Equipment
Shutoff Valve
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.­
A. This appliance has a pilot which must be lighted
by pushing the ignitor button. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
Closed
Figure 13
Control Valve
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
To regulated propane
source
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
Equipment
Shutoff Valve
• If you can not reach your gas supplier, call the
Figure 14
Unvented LP-Gas Vent Free Room Heaters
10
fire department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If knob will not
push in or turn by hand, don’t try to repair it call
a qualified service technician or gas supplier.
Force or attempted repair may result in a fire or
explosion.
Installation Instructions and Owner’s Manual
THERMOSTAT CONTROL OPERATION
D. Do not use this appliance if any part has been
underwater. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system which
has been underwater.
FOR IR20LPT / IR30LPT: The thermostatic control
used simply turns on and off the burner.
FOR BF20LPT / BF30LPT: The thermostatic control
used modulates the flame size as the temperature gets
closer to set point, then it turns off the burner upon
reaching temperature.
The burner will cycle back on when room temperature
drops below the set temperature. The control knob can
be set to any heat level between 1 and 5. Selecting the
HI setting will cause the burner to remain on.
LIGHTING INSTRUCTIONS
1. STOP! Read the all safety information included
with and on the side of heater.
2. Turn off all electric power to the appliance and
make sure the equipment shutoff valve is fully open.
3. Push in gas control knob and slightly turn
clockwise
to the OFF position (see
figure 16).
4. Wait five (5) minutes to clear out any gas.
Then smell for gas including near the floor. If
you smell gas, STOP! Follow “B” in the safety
information above. If you do not smell gas, go
to the next step.
5. Push in and turn control knob
counterclockwise
to PILOT. Press in
control knob for five (5) seconds.
Note: The first time that the heater is operated after
connecting the gas supply, the control knob should
be depressed for about 30 seconds. This will allow
air to bleed from the gas system. This may take
longer in some installations
Ignitor Button
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF HEATER
1. Turn control knob clockwise
to the OFF
position.
2. Turn off all electrical power to the appliance if
servicing is to be preformed.
3. Turn off equipment shutoff valve.
SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)
1. Turn control knob clockwise
PILOT/IGN position.
to the
INSPECTING BURNER
Check pilot flame pattern and burner flame pattern
often.
PILOT FLAME PATTERN
Control Knob
Figure 17 shows a correct pilot flame pattern and
incorrect pilot flame pattern. The incorrect pilot flame
pattern is not touching thermocouple. This will cause
the thermocouple to cool. When the thermocouple
cools, the heater will shut down. If pilot flame pattern is
incorrect, as shown in Figure 17:
• Turn heater off (see To Turn OFF Gas to
Appliance, above.
Figure 16.
6. With control knob pressed in, push down and
release the ignition button. This will light pilot. If
needed keep pressing igniter button until pilot
lights.
7. Keep control knob pressed in for (30) seconds
after lighting pilot. After 30 seconds, release
control knob.
• See Troubleshooting, pages 14-15.
• If pilot does not stay lit, refer to Troubleshooting, pages 14 & 15. Also, contact a qualified
service person of gas supplier for repairs.
Correct pilot position.
Incorrect pilot position.
Figure 17
• If control knob does not pop up when released,
contact a qualified service person or gas
supplier for repairs.
8. When the pilot is lit, turn control knob
counterclockwise
to heating level. The
main burner should light.
9. To select the desired heat level, turn the
temperature setting knob counterclockwise
to between 1 & 5.
Unvented LP-Gas Vent Free Room Heaters
11
Installation Instructions and Owner’s Manual
CLEANING AND MAINTENANCE
CLEANING HEATER CABINET
WARNING: Turn off heater and let cool before
servicing.­
CAUTION: You must keep control areas, burner
and circulation air passageways of heater clean.
Inspect these areas of heater before use. Have
the heater inspected yearly by a qualified service
person. Heater may need more frequent cleaning
due to excess lent from carpeting, bedding material,
pet hair, etc.­
Make sure grille guard is in place before running
heater. If screen or grille guard is removed for
servicing it must be replaced prior to operating the
heater.­
WARNING: Failure to keep the primary air
opening(s) of the burner(s) clean may result in
sooting and property damage.­
Air passageways
• Use a vacuum cleaner or pressurized air to
clean
Exterior
• Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to remove
dust.
CLEANING ODS/PILOT AND BURNER
• Use as vacuum cleaner, pressurized air or
small soft bristled brush to clean.
CLEANING BURNER PILOT AIR HOLE INLET
We recommend that you clean the unit ever 2,500
hours of operation or every three months. We also
recommend that you keep the burner tube and pilot
assembly clean and free of dust and dirt. To clean these
parts we recommend using compressed air no greater
than 30 psig.
This can be done by using a vacuum cleaner in the
blow position, using compressed air in a can, please
follow the directions on the can. If you don’t follow
directions on the can you could damage the burner or
pilot assembly. In addition, the directions that follow
should also be followed.
1. Shut off the unit, including the pilot. Allow the
unit to cool for at least thirty minutes.
2. Inspect burner and pilot for dust and dirt.
3. Blow air through the port/slots and holes in the
burner.
A yellow tip on the pilot flame indicates dust and dirt in
the pilot assembly. To clean the pilot assembly find the
small pilot air inlet hole about two inches from where
the pilot flame comes out of the pilot assembly (see
figure 18). With the unit off, lightly blow air through the
air inlet hole. You may blow through a drinking straw if
compressed air is not available.
Pilot Air Inlet Hole
Pilot Assembly
Figure 18
Unvented LP-Gas Vent Free Room Heaters
12
Installation Instructions and Owner’s Manual
TROUBLESHOOTING
NOTE: All troubleshooting items are listed in order of operation and likely occurrence.
WARNING: Only a qualified service person should service and repair heater.­
CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.­
Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be
replaced prior to operating the heater.­
WARNING: If you smell gas:­
­
•
•
•
•
•
Shut off gas supply­
Do not try to light any appliance­
Do not touch any electrical switch; do not use any phone in your building­
Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.­
If you cannot reach your gas supplier, call the fire department.­
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint
remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with
combustion air and create odors and possible discoloration of walls and ceilings.
OBSERVED SYMPTOM­
POSSIBLE CAUSE
REMEDY­
When ignitor button is pressed in, there is 1. Ignitor electrode positioned wrong.
no spark at pilot
2. Ignitor electrode is broken.
ODS/pilot lights but flame goes out when
control knob is released
1. Reposition electrode
2. Replace electrode
3. Ignitor electrode not connected to
ignitor.
4. Ignitor cable pinched or wet.
5. Broken ignitor cable.
6. Bad ignitor.
7. Low Battery.
3. Reconnect ignitor cable
1. Gas supply turned off or equipment
shutoff valve closed.
2. Control knob not fully pressed in while
pressing ignition button.
3. Air in gas line when installed.
4. ODS/pilot is clogged.
5. Gas regulator setting is not correct
6. Control knob not in pilot position
7. Thermocouple connection loose at
control valve
8. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This
problem could be caused by one or
both of the following:
a. Low gas pressure
b. Dirty or partially clogged ODS/pilot
1. Turn on gas supply turn off or open
equipment shutoff valve closed
When ignitor button is pressed in, there is 1. Control knob not fully pressed in.
a spark at the ODS/pilot but no ignition
2. Control knob not pressed in long
enough
3. Equipment shutoff valve not fully open
4. Thermocouple damaged
5. Control valve damaged
Unvented LP-Gas Vent Free Room Heaters
13
4. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry.
5. Replace ignitor cable
6. Replace igniter assembly
7. Replace battery
2. Fully press in control knob while pressing ignition button
3. Continue holding down control knob.
Repeat ignition operation until air is
removed.
4. Clean ODS/pilot (see Cleaning and
Maintenance pages 11 and12).
5. Replace gas regulator
6. Turn Control knob to pilot position
1. Press in control knob fully
2. After ODS/pilot lights, keep control
knob pressed in for 30 seconds
3. Fully open equipment shutoff valve
4. Hand tighten thermocouple nut until
snug, and then tighten 1/4 turn more.
5. a. Contact local gas company
b. Clean ODS/pilot (see Cleaning and
Maintenance, pages 11 and 12).
6. Replace thermocouple
7. Replace Control valve.
Installation Instructions and Owner’s Manual
Burner does not light after ODS/pilot is lit
1. Burner orifice is clogged
2. Burner orifice diameter to small
3. Inlet gas pressure is too low
1. Clean burner orifice (see Cleaning and
Maintenance on page 11), or replace
burner orifice
2. Replace burner orifice
3. Contact local gas company
Delayed ignition of burner
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Contact local gas company
2. Clean burner orifice (see Cleaning and
Maintenance on page 11), or replace
burner orifice
Burner backfiring during operation
1. Burner orifice is clogged or damaged
2. Burner damaged
3. Gas regulator defective
1. Clean burner orifice (see Cleaning and
Maintenance on pages 11 and 12), or
replace burner orifice
2. Replace burner
3. Replace gas regulator
Burner plaque(s) does not glow [Infrared
Only]
1. Plaque damaged
2. Control knob set between locked
positions.
3. Inlet gas pressure is too low
1. Replace burner
2. Turn control knob until it locks at desired setting.
3. Replace gas regulator
Slight smoke or odor during initial
operation
1. Residues from manufacturing process
1. Problem will stop after a few hours of
operation
Heater produces a whistling noise when
burner is lit
1. Turning control knob to HI position
when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice.
1. Turn control knob to LO position and
let warm up for a minute.
2. Operate burner until air is removed
from line have gas line checked by
local gas company.
3. Observe minimum installation
clearances (see Figure 4 page 7)
4. Clean burner orifice (see Cleaning and
Maintenance on pages 11 and 12), or
replace burner orifice.
White powder residue forming within
burner box or on adjacent walls or furniture
1. When heated, vapors from furniture
polish, wax, carpet cleaners, etc., turn
into white powder residue
1. Turn heater off when using furniture
polish, wax, carpet cleaner or similar
products.
Heater produces unwanted odors.­
1. Heater burning vapors from paint, hair
spray, glues, etc. See IMPORTANT
statement on page 14.
2. Gas leak. See WARNING statement at
top of page 14.­­
1. Ventilate room. Stop using odor-causing
products while heater is running.­
2. Locate and correct all leaks (see
Checking Gas Connections, page 10)­
Heater shuts off in use (ODS operates)­
1. Not enough fresh air is available­
2. Low line pressure­
3. ODS/pilot is partially clogged­­
1. Open window and/or door for
ventilation­
2. Contact local gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, pages 11 and 12)­­
Gas odor even when control knob is in
OFF position­
1. Gas leak. See WARNING statement at
top of page­14.
2. Control valve is defective­­
1. Locate and correct all leaks (see
Checking Gas Connections, page 10)­
2. Replace control valve­­
Gas odor during combustion
1. Foreign matter between control valve
and burner­
2. Gas leak. See WARNING statement at
top of page­­14.
1. Take apart gas tubing and remove
foreign matter­
2. Locate and correct all leaks (see
Checking Gas Connections, page 10)­
Heater produces a clicking/ticking noise
just after burner is lit or shut off
1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If
noise is excessive, contact qualified
service person
Moisture/condensation noticed on windows
1. Not enough combustion/ventilation air
1. Refer to Fresh Air for Combustion and
Ventilation page 3 through 5.
Unvented LP-Gas Vent Free Room Heaters
14
Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
15
Installation Instructions and Owner’s Manual
PARTS LIST AND DIAGRAM
MODEL: MHVFBF20LPBT / MHVFBF20LPT
ITEM
P/N
PART DESCRIPTION
QTY
ITEM
P/N
PART DESCRIPTION
QTY
1
80094
Wire Guard
1
16
80081
Thermostat Valve
1
2
80096
Front Panel
1
17
N/A
Thermostat Mounting Bracket
1
3
80086
Reflector
1
18
N/A
Back Heat Shield
1
4
80088
Front Heat Shield
1
19
80059
Floor Mount Feet
1
5
80093
Glass
1
20
80097
Back Panel
1
6
80091
Glass Bracket
1
21
N/A
Wall Mounting Bracket
1
7
80085
Burner Assembly
1
22
N/A
Reflector Back Panel
1
8
80056
ODS Pilot Assembly w/ Thermocouple
1
23
80110
Fan Assembly
1
9
80009
Orifice
1
24
80049
Fan Switch
1
10
80073
Orifice Adapter
1
25
80011
Ignitor Module Mounting Bracket
1
11
N/A
Regulator Mounting Bracket
1
26
80019
Ignitor Module
1
12
N/A
Regulator Connection
1
27
80014
Ignitor Wire
1
13
80106
Regulator
1
28
N/A
Burner Left Bracket
1
14
70597
3/8” FTP x 3/8” MPT Elbow
1
29
80013
High Limit Switch (FAN)
1
15
N/A
Burner Right Bracket
1
**
70342
Hardware Kit (not shown)
1
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater
may result in property damage or personal injury.
23
21
24
22
Blower not
included on all
units
25
26
29
20
27
17
28
10
7
6
18
16
8
11
15
9
12
13
5
14
4
3
2
1
Unvented LP-Gas Vent Free Room Heaters
16
Installation Instructions and Owner’s Manual
19
PARTS LIST AND DIAGRAM
MODEL: MHVFBF30LPBT / MHVFBF30LPT
ITEM
P/N
PART DESCRIPTION
QTY
ITEM
P/N
PART DESCRIPTION
QTY
1
80041
Wire Guard
1
16
80081
Thermostat Valve
1
2
80065
Front Panel
1
17
N/A
Thermostat Mounting Bracket
1
3
80025
Reflector
1
18
N/A
Back Heat Shield
1
4
80029
Heat Shield
1
19
80058
Floor Mount Feet
1
5
80039
Glass
1
20
80066
Back Panel
1
6
80035
Glass Bracket
1
21
80037
Wall Mounting Bracket
1
7
80018
Burner Assembly
1
22
N/A
Reflector Back Panel
1
8
80059
ODS Pilot Assembly w/ Thermocouple
1
23
80110
Fan Assembly
1
9
80009
Orifice
1
24
80049
Fan Switch
1
10
80073
Orifice Adapter
1
25
80011
Ignitor Module Mounting Bracket
1
11
N/A
Regulator Mounting Bracket
1
26
80019
Ignitor Pulse
1
12
N/A
Regulator Connection
1
27
80014
Ignitor Wire
1
13
80082
Regulator
1
28
N/A
Burner Left Bracket
1
14
70597
3/8” FTP x 3/8” MPT Elbow
1
29
80013
High Limit Switch (FAN)
1
15
N/A
Burner Right Bracket
1
**
70342
Hardware Kit (not shown)
1
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater
may result in property damage or personal injury.
23
BF30TB NG
BF30T NG
21
24
22
Blower not
included on all
units
25
26
29
20
27
17
28
10
7
6
18
16
8
11
15
9
12
13
5
14
4
3
2
1
Unvented LP-Gas Vent Free Room Heaters
17
Installation Instructions and Owner’s Manual
19
PARTS LIST AND DIAGRAM
MODEL: MHVFRD20LPBT / MHVFRD20LPT
ITEM
P/N
PART DESCRIPTION
QTY
ITEM
P/N
PART DESCRIPTION
QTY
1
80094
Wire Guard
1
14
N/A
Thermostat Mounting Bracket
1
2
80096
Front Panel
1
15
N/A
Back Heat Shield
1
3
80086
Reflector
1
16
80058
Floor Mounting Feet
1
4
80057
ODS Assembly w/ Thermocouple (NG)
1
17
80097
Back Panel
1
5
N/A
ODS Bottom Bracket
1
18
80037
Wall Mounting Bracket
1
6
80108
Burner Assembly
1
19
N/A
Heat Shield Reflector
1
7
70597
3/8” FTP x 3/8” MPT Elbow
1
20
80110
Fan Assembly
1
8
80107
Regulator
1
21
80011
Ignitor Module Mounting Bracket
1
9
N/A
Regulator Connection
1
22
80019
Ignitor Pulse
1
10
N/A
Regulator Mounting Bracket
1
23
80014
Ignitor Wire
1
11
80009
Orifice
1
24
80013
High Limit Switch (Fan)
1
12
N/A
Bracket Plenum Assembly
1
25
80049
Fan Switch
1
13
80081
Thermostat Valve
1
**
70342
Hardware Kit (not shown)
1
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater
may result in property damage or personal injury.
25
18
20
19
Blower not
included on all
units
21
22
17
24
23
14
15
13
12
11
10
9
6
8
7
5
4
3
2
1
Unvented LP-Gas Vent Free Room Heaters
18
Installation Instructions and Owner’s Manual
16
PARTS LIST AND DIAGRAM
MODEL: MHVFRD30LPBT / MHVFRD30LPT
ITEM
P/N
PART DESCRIPTION
QTY
ITEM
P/N
PART DESCRIPTION
QTY
1
80041
Wire Guard
1
14
N/A
Thermostat Mounting Bracket
1
2
80065
Front Panel
1
15
N/A
Back Heat Shield
1
3
80023
Reflector
1
16
80058
Floor Mounting Feet
1
4
80057
ODS Assembly w/ Thermocouple (NG)
1
17
80066
Back Panel
1
5
N/A
ODS Bottom Bracket
1
18
80037
Wall Mounting Bracket
1
6
80109
Burner Assembly
1
19
N/A
Heat Shield Reflector
1
7
70597
3/8” FTP x 3/8” MPT Elbow
1
20
80110
Fan Assembly
1
8
80083
Regulator
1
21
80011
Ignitor Module Mounting Bracket
1
9
N/A
Regulator Connection
1
22
80019
Ignitor Pulse
1
10
N/A
Regulator Mounting Bracket
1
23
80014
Ignitor Wire
1
11
80009
Orifice
1
24
80013
High Limit Switch (Fan)
1
12
N/A
Bracket Plenum Assembly
1
25
80049
Fan Switch
1
13
80081
Thermostat Valve
1
**
70342
Hardware Kit (not shown)
1
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater
may result in property damage or personal injury.
25
18
20
19
Blower not
included on all
units
21
22
17
24
23
14
15
13
12
11
10
9
6
8
7
5
4
3
2
1
Unvented LP-Gas Vent Free Room Heaters
19
Installation Instructions and Owner’s Manual
16
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY.
REPLACEMENT PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or
direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001
www.mrheater.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in
all communication.
LIMITED WARRANTY
Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in
material and workmanship for a period of 1 year from date of purchase. Mr. Heater,
Inc. will repair or replace this product free of charge if it has been proven to be
defective within the 1-year period, and is returned at customer expense with proof
of purchase to Mr. Heater, Inc. within the warranty period.
Mr. Heater, Inc. reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademarks of Mr. Heater, Inc.
© 2017, Mr. Heater. All rights reserved
ANSI Z21.11.2 - 2013
Unvented LP-Gas Vent Free Room Heaters
20
Installation Instructions and Owner’s Manual
Download PDF