TFC Coaxial Cable Product Information Sheet
Type: T11FEPQ60/60-D(CMP) NATURAL
Series 11 Coaxial Cable
Copper Clad Steel Conductor
Foamed FEP Dielectric
Bonded Overlap APA Laminate Shield
60% Aluminum Braid
APA Laminate Shield
60% Aluminum Braid
Natural PVDF Jacket, Plenum
NEC / CEC 800 CMP Listed
NFPA 262
Cable Ordering Information
Part Number
011Q66D02NA5010000R1
Description
NEC / CSA Listing
T11FEPQ60/60-D(CMP)
NATURAL
NEC / CEC 800 CMP
Detail
inches
Copper Clad Steel
---
0.0641
0.280
0.288
0.312
0.316
0.341
--0.372
-----
(less reel)
1.5
68 lbs /kft
Characteristics
Material
Inner Conductor
Dielectric
st
1 Outer Conductor
nd
2 Outer Conductor
rd
3 Outer Conductor
th
4 Outer Conductor
Floodant
Jacket
Twisted Pairs
Messenger
Foamed FEP
Sealed at Overlap APA Tape
60% Aluminum Braid
APA Tape
60% Aluminum Braid
--PVDF, Flame Retardant, Natural
---
mm
1.63
7.11
7.32
7.92
8.03
8.66
--9.45
-----
Mechanical Specifications
Minimum Bend Radius, in. (mm)
Product Weight
Customers are reminded that they are SOLELY responsible for confirming that all
products are properly installed and used in accordance with all applicable codes and
regulations.
Document:
Revision:
Page:
t11fepq6060-d[cmp] natural_1ghz15.docx
4.27.2015
1 of 2
uncontrolled copy
All Rights Reserved,
Specifications subject to change without notice
(38.10)
Times Fiber Communications, Inc.
358 Hall Avenue
Wallingford, CT 06492
Toll Free +1-800-677-2288
Toll
+1-434-432-1800
Fax
+1-434-432-1821
www.timesfiber.com
TFC Coaxial Cable Product Information Sheet
Type: T11FEPQ60/60-D(CMP) NATURAL
Electrical Specifications
Impedance, Ω
75 ± 3
Velocity of Propagation, %
Notes:
82
Capacitance, Nominal
DC Resistance
16.0 pF/ft
52.4 pF/m
Ω / kft
Ω / km
Inner Conductor
12.3
40
Outer Conductor
3.16
10
Loop
15.5
50
Attenuation, Maximum @ 68 °F (20 °C)
Frequency, MHz
dB / 100 ft
dB / 100 m
5
0.33
1.08
55
1.16
3.81
211
2.49
8.17
250
2.71
8.89
270
2.81
9.22
300
2.96
9.71
330
3.11
10.20
350
3.20
10.50
400
3.52
11.55
450
3.85
12.63
500
4.06
13.32
550
4.26
13.98
600
4.48
14.70
750
5.21
17.09
870
5.61
18.41
1000
6.19
20.31
Customers are reminded that they are SOLELY responsible for confirming that all
products are properly installed and used in accordance with all applicable codes and
regulations.
Document:
Revision:
Page:
t11fepq6060-d[cmp] natural_1ghz15.docx
4.27.2015
2 of 2
uncontrolled copy
All Rights Reserved,
Specifications subject to change without notice
Times Fiber Communications, Inc.
358 Hall Avenue
Wallingford, CT 06492
Toll Free +1-800-677-2288
Toll
+1-434-432-1800
Fax
+1-434-432-1821
www.timesfiber.com
Download PDF