FEATURES & SPECIFICATIONS
INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of
AC power. Ideal for applications requiring attractive unit equipment with quick installation.
CONSTRUCTION — White, compact, low-profile contemporary design. Engineering-grade thermoplastic
housing is impact-resistant, scratch-resistant and corrosion-proof. UL94V-0 flame rating. UV-stable resin
resists discoloration from natural and man-made light sources.
OPTICS — Two 5.4W wedge-based krypton lamps offer 32 percent more light output than standard
incandescent lamps.
Patented, MR24, multi-faceted reflector significantly improves photometric performance – 60 to 100 percent
more light delivered to path of egress.
U.S. Patent No. D484,272
Low-profile, integrated test switch/pilot light. Easily visible bright red status indicator.
ELECTRICAL — Current-limiting charger maximizes battery life and minimizes energy consumption.
Provides low operating costs.
Short-circuit protection – current-limiting charger circuitry protects printed circuit board from shorts.
Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term
durability.
Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and
charger failure.
Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient
temperature.
Battery: Sealed, maintenance-free lead acid (SLA) provides 12W rated capacity. Automatic 48-hour recharge
after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection.
Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents
over/under charging that shortens battery life and reduces capacity.
Filtered charger input minimizes charge voltage ripple and extends battery life.
AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from
deep discharge
Brownout protection is automatically switched to emergency mode when supply voltage drops below
80 percent of nominal.
INSTALLATION — Unique track-and-swivel arrangement permits full range of direction of lamp head
adjustment. Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry
provision on top of the unit. Ceiling mount standard. US Patent No. D473,627.
LISTINGS — Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards.
Meets all applicable FCC requirements.
WARRANTY — 3-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Actual performance may differ as a result of end-user environment and application.
Specifications subject to change without notice.
ORDERING INFORMATION
Notes
Type
Thermoplastic Emergency Light
ELM2
Lead-acid (SLA) Battery
Example: ELM2
For shortest lead times, configure product using standard options (shown in bold).
ELM2
Family
ELM2
Accessories2: Order as separate item.
ELA VS
Thermoplastic vandal shield1
ELA WG1
Wireguard, 15”W x 13-1/2”H x 6”D2
EMERGENCY
Notes
1 See spec sheet ELA-RTLP-MS-VS2.
2 See spec sheet ELA-WG.
ELM2
ELM2 Quantum® Thermoplastic Emergency Light
SPECIFICATIONS
MOUNTING
All dimensions are inches (centimeters).
Shipping weight: 4.0 lbs. (1.8 kgs.).
ELECTRICAL
Primary Circuit
Type
Input
Amps
.11
.12
Volts
120
277
ELM2
Output
volts
Watts
1.2
1.5
6
12-1/2
(31.8)
Watts output
1-1/2 hrs.
2hrs.
12
9
5
(12.7)
BATTERY
Sealed Lead Acid (SLA)
3-3/4
(9.5)
*with lead calcium alloy grids
Voltage
Typical
Shelf life1
Typical
life1
Maintenance2
6
12 months
5 - 7 years
none
Optimum
temperature3
60°– 90°F
(16°– 32°C)
1 At 77°F (25°C).
2 All life safety equipment, including emergency lighting for path of egress, must be maintained, serviced and
tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the
required maintenance, service or testing could jeopardize the safety of occupants and will void all warranties.
3 Optimum ambient temperature range where unit will provide capacity for 30 to 90 minutes. Higher and lower
temperatures affect life and capacity.
Mounting Plate
1-7/8 2-1/2
(4.8) (6.4)
5
(12.7)
3-7/8
(9.9)
11-1/2
(29.2)
5-5/8
(14.3)
3-1/2
(8.9)
3-3/4
(9.5)
12-1/2
(31.7)
LAMP PHOTOMETRICS
FIXTURE PERFORMANCE
LTL10586
MR24 K0606
6-volts, 5.4-watts krypton
Center-to-Center
Spacing*
yields 20'
HORIZONTAL
6
4
Single-Unit
Coverage*
yields 18'
2
1
0
0.5
0.3
2
0.1 FC min.
4
1 FC average
6
VERTICAL
6
4
18 ft.
2
1
0
0.5
0.3
6-Foot Path of Egress
2
6 ft.
4
6
10
20
Ft.
Center-to-Center
Spacing*
yields 25'
SPACING/COVERAGE GUIDE
Path of Egress
MR24 K0606
Lamp
3'-wide
0.1 FC min.
6'-wide
Center-to-Center Spacing
25’
20’
Single-Unit Coverage
24’
18’
Single-Unit
Coverage*
yields 24'
1 FC average
24 ft.
3-Foot Path of Egress
3 ft.
* Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open
space with no obstructions, mounting height: 7.5’, ceiling height: 9’, and reflectances: 80/50/20. Analysis based on
independently tested photometrics.
ELM2
EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800.334.8694 www.lithonia.com
©1991-2017 Acuity Brands Lighting, Inc.
All rights reserved. Rev. 06/28/17