1. Before You Begin .......................................................................
What Is Included ...........................................................................................
Unpacking Instructions..................................................................................
Claims ............................................................................................................................
Text Conventions ..........................................................................................
Symbols ........................................................................................................
Disclaimer .....................................................................................................
Safety Notes..................................................................................................
2. Introduction ................................................................................
Product Overview..........................................................................................
Product Dimensions ......................................................................................
3. Setup ...........................................................................................
AC Power ......................................................................................................
Fuse Replacement .........................................................................................................
Mounting .......................................................................................................
Orientation......................................................................................................................
Rigging ...........................................................................................................................
Inverting the Tank ..........................................................................................................
4. Operation ....................................................................................
Control Panel Operation................................................................................
Menu Map .....................................................................................................
Configuration (DMX) .....................................................................................
Starting Address.............................................................................................................
DMX Channel Assignments and Values ........................................................................
Configuration (Standalone) ...........................................................................
Geyser Wireless Remote Control...................................................................................
5. Maintenance and Storage..........................................................
Fog Machine Maintenance............................................................................
Storage..........................................................................................................
6. Technical Specifications ...........................................................
Returns............................................................................................
Contact Us ......................................................................................
1
1
1
1
1
1
1
2
3
3
3
4
4
4
4
4
4
5
6
6
6
7
7
7
8
8
9
9
9
10
11
12
Geyser P7 User Manual Rev. 1
Before You Begin
1. Before You Begin
What Is Included
•
•
•
Geyser P7
Power Cord
Geyser wireless remote control and receiver
•
•
Warranty Card
Quick Reference Guide
Unpacking Instructions
Carefully unpack the product immediately and check the container to make sure all the parts are in the
package and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear damaged from shipping, or show
signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier
immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Chauvet within 7 days of delivery.
Text Conventions
Convention
1–512
50/60
Settings
<ENTER>
ON
Meaning
A range of values
A set of values of which only one can be chosen
A menu option not to be modified
A key to be pressed on the product’s control panel
A value to be entered or selected
Symbols
Symbol
Meaning
Critical installation, configuration, or operation information. Not following these
instructions may make the product not work, cause damage to the product, or cause
harm to the operator.
Important installation or configuration information. The product may not function
correctly if this information is not used.
Useful information.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However,
Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss,
damage or disruption caused by any errors or omissions in this document, whether such errors or
omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the
content of this document without any obligation to notify any person or company of such revision, however,
Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest
version from www.chauvetdj.com.
The works of authorship contained in this manual, including, but not limited to, all design, text and images
are owned by Chauvet.
© Copyright 2017 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America.
CHAUVET, the Chauvet logo, and Geyser P7 are registered trademarks or trademarks of Chauvet & Sons
LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and
product names and logos referred to herein may be trademarks of their respective companies.
Geyser P7 User Manual Rev. 1
Page 1 of 12
Before You Begin
Safety Notes
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Not intended for permanent installations.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect this product from the power source before cleaning it or replacing the
fuse.
Make sure the power cord is not crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Do not mount this product on a flammable surface (e.g., wood, linoleum, carton, plastic, or
carpet).
Make sure there are no flammable materials close to the unit while operating
Do not touch the output nozzle on this product. It is very hot during operation and it may
remain hot for several hours after turning the unit off.
Do not drink the fog fluid. If you do, call your local emergency service (911 in the US) for
help.
Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
Depending on the amount of fog generated, all fog machines may set off smoke detectors.
In certain environments, fog fluid-based machines may leave a slippery residue on floors
and surfaces.
Do not use for space heating purposes.
Use only CHAUVET® DJ water-based fog fluid.
Drain the tank before transporting the product.
Always make sure that the voltage of the outlet to which you are connecting the product is
within the range stated in the decal or rear panel of the product.
This product is for indoor use only! To prevent risk of fire or shock, do not expose this
product to rain or moisture.
Always install this product in a location with adequate ventilation, at least 20 in (50 cm) from
adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Never connect this product to a dimmer or rheostat.
Make sure to replace the fuse with another of the same type and rating.
Never carry the product from the power cord or any moving part. Always use the handle.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate this product at
higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair this product. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Keep this User Manual for future use. If you sell the product to someone else, be sure that
they also receive this document.
Page 2 of 12
Geyser P7 User Manual Rev. 1
Introduction
2. Introduction
Product Overview
LED
Penta-color LEDs
Nozzle
Display Zone 2
Zone 1
Power
Menu
Switch
Power
Buttons
In
Controller
Fuse
In
Holder
DMX In/Out
(3- and 5-pin)
Removable Shield
Fluid Tank
Carry
Handle
Safety Fan
Loop
Fluid Level
Indicator
Rubber Feet for
Surface Mounting
(x4)
Product Dimensions
14.2 in
362 mm
15.7 in
400 mm
8.2 in
210 mm
Geyser P7 User Manual Rev. 1
Page 3 of 12
Setup
3. Setup
AC Power
The Geyser P7 has a fixed voltage power supply and it can work with an input voltage of either 120 VAC,
60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.
• Always connect the product to a protected circuit (a circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
1.
2.
3.
4.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
Pry the fuse holder out of the housing.
Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
Insert the fuse holder back in place and reconnect power.
Installed fuse
(held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap
Disconnect the product from the power outlet before replacing the fuse.
While operating the Geyser P7, make sure there is adequate fog fluid in the machine
to prevent pump and heater damage. When the fog fluid level becomes low, simply
add more fog fluid to continue using the Geyser P7.
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
To prevent leaking or spilling, always position the fluid tank with its cap in the
uppermost position, above the fog fluid line.
Rigging
•
•
•
•
•
•
Before deciding on a location, always make sure there is easy access to the product for
maintenance and fluid replenishment.
Make sure adequate ventilation is provided around the product.
Make sure that the structure or surface onto which you are mounting the product can support the
product’s weight. (see the Technical Specifications)
When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, such as an elevated platform or a truss.
When rigging the product onto a truss, you should use a mounting clamp of appropriate weight
capacity. The bracket has 13-mm holes, which are appropriate for this purpose.
The rubber feet also serve as floor supports and allow for surface mounting. When mounting the
product on the floor, make sure that the product and cables are away from people and vehicles.
Page 4 of 12
Geyser P7 User Manual Rev. 1
Setup
Inverting the Tank
To prevent leaking or spilling, always position the fluid tank with its cap in the uppermost position, above
the fog fluid line. When mounting the Geyser P7 overhead, invert the fluid tank by doing the following:
1. Detach the removable shield by removing the thumb-screw.
2. Pull the fluid tank out and set it on a flat surface.
3. Detach the fluid tank plate by removing 4 screws.
4. Secure the fluid tank plate to the opposite side with the 4 screws.
5. Insert the fluid tank.
6. Secure the removable shield by inserting the end without the thumbscrew into the slot, and
screwing in the thumbscrew.
Mounting Diagram
Fluid Tank Plate
Screws (x4)
Upwards Fog Output
Omega Bracket Placement Options
Downwards Fog Output
Mounting Clamp (x2)
Omega Bracket (x2)
Safety Cable
Omega Bracket (x2) Mounting Clamp (x2) Safety Cable
Omega Bracket (x2)
Mounting Clamp (x2)
Surface Mounting
Horizontal Fog Output
To prevent leaking or spilling, always position the fluid tank with its cap in the
uppermost position, above the fog fluid line.
Geyser P7 User Manual Rev. 1
Page 5 of 12
Operation
4. Operation
Control Panel Operation
To access the control panel functions, use the four buttons located underneath the display, and the two
manual control knobs located to the right of the display. Please refer to the Product Overview to see the
button locations on the control panel.
Button
<MENU>
<UP>
<DOWN>
<ENTER>
Function
Press to find an operation mode or to back out of the current menu option
Press to scroll up the list of options or to find a higher value
Press to scroll down the list of options or to find a lower value
Press to activate a menu option or a selected value
Menu Map
Main Level
Programming Levels
Addr
1–512
oFF
Co 1
Co 2
Co 3
Co 4
Co 5
Co 6
Co 7
Co 8
Co 9
Co10
Co11
Co12
Co13
Co14
Co15
Co16
Co17
Co18
Co19
Co20
rand
CH 1–4
Page 6 of 12
Description
Sets the DMX starting address
No color output
Red
Green
Blue
Amber
Ultraviolet
Hot pink
Magenta
Yellow
Cyan
White
Zone 1 green, zone 2 red
Zone 1 blue, zone 2 red
Zone 1 red, zone 2 green
Zone 1 blue, zone 2 green
Zone 1 red, zone 2 blue
Zone 1 green, zone 2 blue
Zone 1 amber, zone 2 magenta
Zone 1 blue, zone 2 magenta
Zone 1 magenta, zone 2 amber
Zone 1 hot pink, zone 2 blue
Random color output
Geyser P7 User Manual Rev. 1
Operation
Configuration (DMX)
The Geyser P7 works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer,
which is available from the Chauvet website http://www.chauvetlighting.com/downloads/
DMX_Primer_rev05_WO.pdf.
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels the selected DMX
mode uses. If you choose a starting address that is too high, you could restrict the access to some of the
product’s channels.
The Geyser P7 uses 15 DMX channels, which defines the highest configurable address to 498.
If you are not familiar with the DMX protocol, download the DMX Primer from www.chauvetdj.com.
To select the starting address, do the following:
1. Press <MENU> repeatedly until Addr shows on the display.
2. Use <UP> or <DOWN> to select the starting address, from 1–512.
3. Press <ENTER>.
DMX Channel Assignments and Values
Channel
Function
1
Fog
2
Zone 1 Red
3
Zone 1 Green
4
Zone 1 Blue
5
Zone 1 Amber
6
Zone 1 Ultraviolet
7
Zone 2 Red
8
Zone 2 Green
9
Zone 2 Blue
10
Zone 2 Amber
11
Zone 2 Ultraviolet
12
Color Macro
13
Color Macro Speed
14
Strobe
15
Dimmer
Geyser P7 User Manual Rev. 1
Value
000 009
010 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
000 014
015 255
015 009
010 009
000 009
010 255
000 009
010 255
000 014
015 255
Percent/Setting
No function
Output fog
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
0–100%
No function
Color macros
No function
Color macro speed, slow to fast
No function
Strobe, slow to fast
No function
0–100%
Page 7 of 12
Operation
Configuration (Standalone)
After connecting power, allow 4 to 5 minutes for the Geyser P7 to heat up before
triggering fog output.
Geyser Wireless Remote Control
The included Geyser wireless remote control and receiver allows up to 4 preset colors or programs to be
triggered from up to 100 ft (30 m) away.
To configure which color or program gets triggered by which button on the Geyser wireless remote control
(<1>–<4>), follow the instructions below.
1. Press <MENU> repeatedly to select the button to configure, from CH 1 (<1>), CH 2 (<2>), CH 3
(<3>), or CH 4 (<4>).
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select the output when the selected button is pressed, from oFF (no
color output), Co 1 (red), Co 2 (green), Co 3 (blue), Co 4 (amber), Co 5 (ultraviolet), Co 6 (hot
pink), Co 7 (magenta), Co 8 (yellow), Co 9 (cyan), Co10 (white), Co11 (zone 1 green, zone 2
red), Co12 (zone 1 blue, zone 2 red), Co13 (zone 1 red, zone 2 green), Co14 (zone 1 blue, zone
2 green), Co15 (zone 1 red, zone 2 blue), Co16 (zone 1 green, zone 2 blue), Co17 (zone 1
amber, zone 2 magenta), Co18 (zone 1 blue, zone 2 magenta), Co19 (zone 1 magenta, zone 2
amber), Co20 (zone 1 hot pink, zone 2 blue), or rand (random color output).
4. Press <ENTER>.
Geyser Wireless Remote Control Overview
Ensure the Geyser remote has an unobstructed view of the product for maximum
performance.
Page 8 of 12
Geyser P7 User Manual Rev. 1
Maintenance and Storage
5. Maintenance and Storage
Fog Machine Maintenance
Do not allow the fog machine to become clogged. After every 40 hours of continuous operation, use
CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter
in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run
dry.
6. Refill with fog fluid to continue using the fog machine. Run the machine briefly to clear any
remaining cleaning solution from the pump and heater.
Do Not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your
Geyser P7. Make sure you use FCQ regularly, no longer than 90 days between
cleanings, to increase the life of your product.
Storage
Before storing the fog machine, run FCQ through the system as described in the cleaning procedure
above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the Geyser
P7. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump
or heater while not in use.
Test-run your Geyser P7 on a monthly basis to achieve the best performance.
Geyser P7 User Manual Rev. 1
Page 9 of 12
Technical Specifications
6. Technical Specifications
Dimensions and Weight
Length
15.7 in (400 mm)
Width
14.2 in (362 mm)
Height
8.2 in (210 mm)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Model-specific
120 VAC, 60 Hz, or 230 VAC, 50 Hz
Weight
18.16 lb (8.5 kg)
Voltage Selection
Fixed
Parameter
Consumption
Operating Current
Fuse
120 V, 60 Hz
1290 W
11.3 A
F 15 A, 250 V
230 V, 50 Hz
1290 W
5.6 A
F 15 A, 250 V
Power I/O
Power input connector
Power Cord plug
U.S./Worldwide
IEC
Edison (U.S.)
UK/Europe
IEC
Local Plug
Tank Capacity
0.7 gal (2.5 l)
Fluid Consumption
90 ml/min
Operation
Heat-Up Time
4 min
Fog Output
Output
17,000 cfm
Light Source
Type
LED
Color
Penta-color
RGBA+UV
Photometrics
Illuminance @ 2 m (Zone 1)
506 lux
Thermal
Maximum External Temperature
104 °F (40 °C)
Quantity
Power
Current
Lifespan
7
9W
3A
50,000 hours
Illuminance @ 2 m (Zone 2)
390 lux
Strobe Rate
0 to 20 Hz
Cooling System
Fan-assisted convection
Ordering
Product Name
Geyser P7 (120 V)
Geyser P7 (230 V)
Page 10 of 12
Item Code
05071331
05071332
UPC Number
781462216795
781462216801
Geyser P7 User Manual Rev. 1
Returns
Returns
In case you need to get support or return a product:
•
If you are located in the U.S., contact Chauvet World Headquarters.
•
If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
•
If you are located in Mexico, contact Chauvet Mexico.
•
If you are located in Benelux, contact Chauvet Europe BVBA.
•
If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local
distributor. See www.chauvetdj.com for distributors outside the U.S., UK, Ireland, Mexico, or
Benelux.
If you are located outside the U.S., UK, Ireland, Mexico, or Benelux, contact your
distributor of record and follow their instructions on how to return Chauvet products to
them. Visit our website www.chauvetdj.com for contact details.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization
(RMA) number before shipping the product. Be prepared to provide the model number, serial number, and
a brief description of the cause for the return.
To submit a service request online, go to www.chauvetdj.com/service-request.
Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet
will not issue call tags.
Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA
number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number
directly on the box.
Before sending the product, clearly write the following information on a piece of paper and place it inside
the box:
•
Your name
•
Your address
•
Your phone number
•
RMA number
•
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be
your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned
product(s).
Geyser P7 User Manual Rev. 1
Page 11 of 12
Contact Us
Contact Us
World Headquarters
General Information
Technical Support
Address: 5200 NW 108th Ave.
Voice: (844) 393-7575
Sunrise, FL 33351
Fax: (954) 756-8015
Voice: (954) 577-4455
Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084
Website
www.chauvetlighting.com
EUROPE
General Information
Technical Support
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Email: eutech@chauvetlighting.eu
Website
www.chauvetlighting.eu
Voice: +32 9 388 93 97
General Information
Address: Unit 1C
Technical Support
Email: uktech@chauvetlighting.com
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Website
www.chauvetlighting.co.uk
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110
MEXICO
General Information
Address: Av. de las Partidas 34 - 3B
(Entrance by Calle 2)
Technical Support
Email: servicio@chauvet.com.mx
Zona Industrial Lerma
Lerma, Edo. de México, CP 52000
Voice: +52 (728) 690-2010
Website
www.chauvet.com.mx
Outside the U.S., United Kingdom, Ireland, Mexico or Benelux, contact the dealer of record. Follow the
instructions to request support or to return a product. Visit our website for contact details.
Page 12 of 12
Geyser P7 User Manual Rev. 1
Download PDF
Similar pages