EJS/EJD - Global Industrial

Catalog Number
Notes
FEATURES & SPECIFICATIONS
INTENDED USE
For mounting heights up to 20’ requiring low to medium light levels. Ideal for
light duty task lighting, aisles, cold ambient spaces, warehousing and storage.
CONSTRUCTION
Channel constructed of die-formed cold rolled steel with longitudinal Vgrooves in channel for strength. Sturdy combination reflector and channel
cover secured by quarter-turn latch for easy access to wireway. Screwon endplates. Available in 4’, or 8’ tandem-wired lengths. Accepts plug-in
option for 1, 2 or 3 primary circuits.
FINISH
Five-stage iron phosphate pretreatment ensuring superior paint adhesion
and corrosion-resistance. Reflector and channel finished with a high-gloss
baked white enamel. Reflector is painted after fabrication.
OPTICAL SYSTEM
Solid-top or apertured uplight reflectors available. Both are painted after
fabrication.
ELECTRICAL SYSTEM
Thermally-protected, resetting, Class P, HPF, non-PCB, UL Listed and CSA Certified ballast is standard. Sound rating depends on lamp/ballast combination.
AWM, TFN, THHN wire throughout, rated for required temperatures.
INSTALLATION
For unit or row installations or suspended mounting. Channel connector
furnished standard.
LISTING
120V and 277V are UL Listed and CSA Certified (standard). 347V is CSA Certified (see Options). NOM Certified (see Options). Suitable for damp locations.
WARRANTY
Guaranteed for one year against mechanical defects in manufacture.
Type
General Purpose Industrial
EJS/EJD
High Output and
Very High Output
2', 4', 6' or 8' Length
1 or 2 Lamps
Specifications
Length:
Width:
Height:
24" (610), 48" (1219), 72" (1829) or
96" (2438)
12" (305)
T8 & T5 4-1/4" (108)
T12 4-15/16" (125)
All dimensions are inches (millimeters).
Specifications subject to change without
notice.
ORDERING INFORMATION
H
W
Example: EJD 2 96HO 120 CW20
Choose the boldface catalog nomenclature that best suits your needs and
write it on the appropriate line. Order accessories as separate catalog number.
Series
EJD General purpose
industrial, no
uplight, T12 lamps
EJS General purpose
industrial, no
uplight, T5 or T8
lamps
EJDA General purpose
industrial, with
uplight, T12 lamps
EJSA General purpose
industrial, with
uplight, T5 or T8
lamps
Number of
lamps
Lamp Type
Voltage
Options
24HO 35W T12 800 mA (24")
120
ES
1, 2, 31
48HO 60W T12 800 mA (48")
277
CW20
Not included
48VHO 110W T12 1500 mA (48")
347
EL14
Emergency battery pack (nominal 1400 lumens). See Life Safety Section
EL55
Emergency battery pack for T5 lamps (nominal
390-700 lumens; see Fluorescent Battery
Packs Section)
48T8HO 44W T8 380 mA (48")
MVOLT1
54T5HO 54W T5 HO (46")
Others
available
72HO 85W T12 800 mA (72")
72T8HO 65W T8 380 mA (72")
96HO 110W T12 800 mA (96")
96VHO 215W T12 1500 mA (96")
96T8HO 86W T8 380mA (96")
For tandem double-length
unit, add prefix T. Example:
TEJS
GEB
Energy-saving ballasts
Cold-weather T12 ballasts, -20°F starting
Electronic T8 or T12 ballasts, <20% THD
GEB10PS
Electronic T5 ballast, <10% THD, Program Start
GEB10RS
Electronic T8 ballasts, <10% THD, Rapid Start
GLR
Internal fast-blow fuse
GMF
Internal slow-blow fuse
PLF_
Plug-in wiring. Specify 1, 2 or 3 branch circuits
& hot wires (A=black, B=red, C=blue, AB or AC)
TILW
Tandem in-line wiring
CSA
NOM
CSA Certified (347V only)
NOM Certified
Accessories
Order as separate catalog numbers.
NOTES:
1 54T5HO only.
2 Order two for 8' fixtures.
Fluorescent
SQ_
1B
HC36
THUN
HRUND1
HRUNS1
WGL
Swivel-stem hanger (specify length in 2" increments)
Ceiling spacer 1-1/2" to 2-1/2" from ceiling
Chain hangers (1 pair, 36" long)
Tong hanger
Hooker® T-bar hanger (1-1/2" from ceiling) for use with EJD
Hooker® T-bar hanger (1-1/2" from ceiling) for use with EJS
Wireguard for EJ reflector, 4' white2
Sheet # EJS-EJD-HO-VHO
INFL-140
EJS/EJD High Output and Very High Output
MOUNTING DATA
DIMENSIONS
For unit or row installation, surface or suspended mounting. Use hanger appropriate for
fixture width.
Inches (millimeters). Subject to change without notice.
Unit installation — Minimum of two hangers required.
Row installation — One hanger per channel plus one per row
required.
Hooker® (HRUND1 or HRUNS1), HC36 and THUN Hangers —
Minimum two per channel (unit and row).
A = 11/16 (18) Dia. K.O.
B = 7/8 (22) Dia. K.O.
C = 2 (51) Dia. K.O.
4-3/8
(111)
See ACCESSORIES below for hanging devices.
4-3/8
(111)
B
C
C
B
4-15/16
(125)
4-1/4
(108)
2-1/2
(64)
12
(305)
2-1/2
(64)
12
(305)
48
24
HRUNS1
A
19
5-1/2
4-1/4
3-1/4
19
5-1/2
4-1/4
3-1/4
B
C
A
A
3-1/4
4-1/4
B
6
A
B
24
43
A
C
B
B
B
B
A
A
A
B
43
48
A
B
A
B
24
4-3/8
4-3/8
3-1/4
4-1/4
5-1/2
96
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on
these and other configurations available upon request.
Coefficients of Utilization
20%
80%
50%
30%
70% 50% 30% 50% 30% 10% 50% 30% 10%
89 89 89
104 104 104 95 95 95
76 74 72
81 78 76
94 90 85
66 62 58
70 65 61
85 77 70
57 52 48
61 55 50
77 67 59
50 45 40
54 47 42
70 59 50
45 39 34
48 41 36
64 52 44
40 34 30
43 36 31
59 46 38
37 31 26
39 32 27
54 42 34
33 27 23
35 29 24
50 38 30
31 25 21
32 26 21
47 35 27
28 23 19
30 23 19
44 32 25
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0˚ - 30˚
3026
18.1
20.3
0˚ - 40˚
5104
30.6
34.2
0˚ - 60˚
9777
58.5
65.5
0˚ - 90˚
13543
81.1
90.7
90˚ - 180˚ 1381
8.3
9.3
0˚ - 180˚ 14924
89.4
100.0
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
Coefficients of Utilization
20%
80%
50%
30%
70% 50% 30% 50% 30% 10% 50% 30% 10%
89 89 89
104 104 104 95 95 95
76 74 72
81 78 76
94 90 85
66 62 58
70 65 61
85 77 70
57 52 48
61 55 50
77 67 59
50 45 40
54 47 42
70 59 50
45 39 34
48 41 36
64 52 44
40 34 30
43 36 31
59 46 38
37 31 26
39 32 27
54 42 34
33 27 23
35 29 24
50 38 30
31 25 21
32 26 21
47 35 27
28 23 19
30 23 19
44 32 25
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0˚ - 30˚
1540
18.1
20.3
0˚ - 40˚
2598
30.6
34.2
0˚ - 60˚
4976
58.5
65.5
0˚ - 90˚
6893
81.1
90.7
90˚ - 180˚ 703
8.3
9.3
0˚ - 180˚
7596
89.4
100.0
EJD 2 96VHO
Report: LTL12693
LUMENS PER LAMP:14000
Luminaire Efficiency: 85.4%
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
RCR
RCR
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
EJDA 2 48HO
Report: LTL12704
LUMENS PER LAMP:4250
Luminaire Efficiency: 89.4%
RCR
EJDA 2 96HO
Report: LTL12705
LUMENS PER LAMP:8350
Luminaire Efficiency: 89.4%
Coefficients of Utilization
20%
80%
50%
30%
70% 50% 30% 50% 30% 10% 50% 30% 10%
91 91 91
102 102 102 95 95 95
79 76 74
82 79 76
92 88 84
68 64 60
71 66 61
83 75 69
59 54 50
61 55 51
75 65 58
52 46 42
54 48 42
68 58 50
46 41 36
48 41 36
63 51 43
42 36 31
43 37 31
58 46 38
38 32 27
39 32 28
53 41 33
35 29 24
36 29 24
50 38 30
32 26 22
33 26 22
46 34 27
29 24 20
30 24 20
43 32 25
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0˚ - 30˚
5555
19.8
23.2
0˚ - 40˚
9331
33.3
39.0
0˚ - 60˚
17593
62.8
73.6
0˚ - 90˚
23914
85.4
100.0
90˚ - 180˚
0
0.0
0.0
0˚ - 180˚ 23914
85.4
100.0
Lithonia Lighting
Sheet #: EJS-EJD-HO-VHO
©2004 Acuity Lighting Group, Inc. 5/06
Fluorescent
One Lithonia Way, Conyers, GA 30012
Phone: 800-858-7763, Fax: 770-929-8789
www.lithonia.com
Download PDF