BEGA
Installation and Technical Information
Floodlight - small scale with mounting canopy
7516
Tools Required:
Phillips medium screw driver
3 mm Hex Key
5 mm Hex Key (for optional knuckle adjustment)
Dimensions
UL listed, suitable for wet locations.
A:
4-1/4 “
B:
8-7/16 “
C:
6-1/2 “
Protection Class: IP 65
Weight: 3.0 lbs.
Notice to Installer for 7516:
1. In conformance with UL Standard 1598, a silicone based sealant
must be used between luminaire and supporting wall.
2. Luminaire mounts directly to a 3 1/2” or 4” standard octagonal
wiring box (by others)
7516 installation:
1. Undo the (2) screws on the front of the luminaire mounting canopy,
and separate the front half (with luminaire attached) and back/bottom
half of the canopy.
2. Attach provided mounting platedirectly to a 3 1/2” or a 4” standard
octagonal wiring box using the (2) screws (provided).
3. Make supply wiring and luminaire wiring connections inside the
wiring box:
MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE
GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE
4. Place a small bead of silicone around the back side of the mounting
canopy (or optional decorative cover if used) that will come in contact
with the finished wall (exterior applications only).
5, Align and position back half of mounting canopy on mounting
surface.
6. Slip decorative cover and mounting canopy over the mounting
plate. Attach the canopy to the center of the plate by using the screw
with lockwasher and nipple provided with the mounting kit. Secure the
canopy tightly.
7. Replace front half of mounting canopy (with attached luminaire)
using provided (2) screws.
8. Undo faceplate screws and remove faceplate with lens and
reflector.
9. Insert lamp (by others). Replace lens, reflector, and faceplate and
tighten screws to secure.
Relamping/Maintenance
Undo faceplate screws and remove casting. Carefully
remove diffuser, gasket and reflector. Clean luminaire
and lens using only solvent-free cleansers. Relamp, and
carefully replace reflector, diffuser , gasket and casting.
Lamp:
(1) 100W T4 DCB
Philips :
100Q/CL/DC ESR
Osram/Sylvania :
100Q/CL/DC
GE :
Q100CL/DC
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
Green color filter
Blue color filter
Yellow color filter
Wide beam diffuser lens
Linear spread lens
180° glare shield
125
126
127
312
313
264
Replacement Parts
Description
Part No
Diffuser
Gasket
Lampholder
140188
830488
US3064
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.