TM
PENDANT INSTALLATION INSTRUCTIONS
B
END VIEW
NOTE: THE JUNCTION BOXES MUST BE SOLIDLY FIXED
TO THE CEILING AND ATTACHED TO THE STRUCTURE
INSIDE THE CEILING BEFORE PROCEEDING TO THE
INSTALLATION.
23/4"
PART LIST
A
B
C
D
E
F
G
H
I
Power cord
Ceiling power feed (by others)
Canopy
1/ - 20 threaded stud (by others)
4
Cable mounting nut
Aircraft cable
Cable Grip
Cable Grip security nut
Fixture 1
J
K
L
M
N
O
P
Q
R
Wire ferrule
Setscrew
Plastic clips
Joining wedges
Quick-wire connectors
Fixture 2
Electrical wires
Screws
Wire nuts
knot
UL1598
R
12"
Example of a junction box in a
ceiling (Installation sheets for all
mounting options are available at:
www.axislighting.com).
SIDE VIEW
A
for mounting points
please consult shop drawing
power
1
Ensure that the power to the fixture’s circuit is turned off. Make
a knot on the power cord inside the canopy. Connect the
power cord (A) to the ceiling power feed (B) with wire nuts (R).
L
C
F
A
D
G
H
H
I
J
E
2
3
At all power feed suspension points, place canopy (C)
in position on threaded stud (D) and secure with cable
mounting nut (E).
Insert aircraft cable (F) into cable grip (G). Press on the security
nut (H) of the cable grip to level and adjust the height of the
fixture, while moving the fixture up and down.
Secure power cord (A) to aircraft cable (F) using plastic clips (L).
Page: 1 / 2
FILE NAME:FLOW.PENDANT.INST December 17, 2014
1.800.263.AXIS
[ T ] 514.948.6272
[ F ] 514.948.6271
www.axislighting.com
4
Secure the fixture by screwing the cable grip security nut
(H) after the adjustments. Install a wire ferrule (J) at the
end of the cable to prevent accidents.
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE
INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE
WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES.
DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
!
Product design and development is an ongoing process at
Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
© 2010 Axis Lighting Inc.
TM
PENDANT INSTALLATION INSTRUCTIONS
C
D
K
D
C
E
F
E
5
6
At all suspension points, place canopy (C) in position on
threaded stud (D) and secure with cable mounting nut (E).
7
Leveling the fixture: Unscrew the setscrew (K) until the aircraft
cable (F) can slide inside. DO NOT UNSCREW THE SETSCREW
COMPLETELY, AS THIS WILL CAUSE THE FIXTURE TO FALL.
Adjust the fixture so it is straight.
M
O
N
I
I
K
Q
F
P
8
9
For a continuous row systems: With first fixture (I) in
place, repeat steps 5 to 8 with the second fixture (O).
Connect the electrical wires (P) between the two fixtures
using supplied quick-wire connectors (N).
Tighten the setscrew (K) to prevent the aircraft cable (F)
from sliding.
www.axislighting.com
O
Connect the second fixture (O) to the first fixture (I) using
the joining wedges (M) and secure with screws (Q).
Install the lamps in the fixtures.
Page: 2 / 2
FILE NAME:FLOW.PENDANT.INST December 17, 2014
1.800.263.AXIS
[ T ] 514.948.6272
[ F ] 514.948.6271
10
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE
INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE
WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES.
DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
!
Product design and development is an ongoing process at
Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
© 2010 Axis Lighting Inc.