AbsoluteCOLOR® • AbsoluteBLACK® • UniDrums • UniRollers • UniParts • UniCoatings
HP 2600N CARTRIDGE REMANUFACTURING INSTRUCTIONS
HP 2600N
COLOR LASER PRINTER
PRELIMINARY
TECHNICAL DETAILS
AND REMANUFACTURING
INSTRUCTIONS FOR
CMYK CARTRIDGES
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
HP 2600N DETAILS
• New Canon engine 8 ppm.
• New AIO Cartridges.
• Miniature ASIC Chip 20% smaller in size than prior chips.
• Smaller and cheaper.
• Size and weight reduction.
• Difficulties to recycle working on options.
• Major challenge to produce compatible chip.
• Below $500,00.00 USD.
ELECTROPHOTOGRAPHIC SYSTEM
• New Canon engine 600 x 600 dpi.
• 780nm ASGl Laser con 4 prisms.
• Single Pass.
• Direct imaging into paper. No transference band.
• New Chemical Toner.
• Fast fusing, accept wide range of media.
CARTRIDGES WITHOUT CHIPS
• Printer Initializes.
• Acts as if cartridge is missing, red light at panel, screen indicates “Install ‘Black’ Cartridge,” etc.
• Immediately shows figure of missing cartridge.
• Without chip in any individual cartridge printer would not work.
• Yellow indicates “10.1003 supply error.”
• Cyan indicates “10.1001 supply error.”
• Magenta indicates “10.1002 supply error.”
• Cannot reset chip and cannot print without chip.
HP 2600N CARTRIDGE
• Gross weight of cartridges are: BLK = 675g. YCM = 642g.
CARTRIDGE DATA
• Black ref. Q6000A yields 2500 A4 pages at 5% coverage.
Hopper with 110g toner.
• Cyan ref. Q6001A yields 2000 A4 pages at 5% coverage.
Hopper with 90 g. toner.
• Magenta ref. Q6003A yields 2000 A4 pages at 5% coverage.
Hopper with 90g toner.
• Yellow ref. Q6002A yields 2000 A4 pages at 5% coverage.
Hopper with 90g toner.
• Optical detection for toner depletion.
• Metal pin left-side acts also as an electrical contact for PCR and Wiper Blade.
• Right-side pin is plastic and hollow, yet it can be extracted to disassemble the cartridge and is
reusable.
• Design of image section is such that it does not allow disassembly of the OPC drum.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CARTRIDGE DISASSEMBLY: METAL PIN REMOVAL
1. Drill a parallel hole 2,5mm x 3mm deep just above the pin at
the front of the cover as shown to allow extraction with needle
pliers.
2. Grip the metal pin to pull it out with pliers. using a pair of
tweezers, move the top metal tab back and forth while pulling
slowly. This will allow disengagement of the pin from the internal
contact without breaking the plate. Do not use apply any undue
force in pulling. See step 15 explaining the consequences.
NOTES
3. Metal pin extracted.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CARTRIDGE DISASSEMBLY: PLASTIC PIN REMOVAL
4. A 2mm (0,078”) conical Boring Tool is used for this procedure.
Alternatively use a 14-13 wood screw.
5. Thread the tool 3 or 4 turns into the plastic pin hole.
6. Once tool is firmly into the pin, start pulling straight out to dislodge the pin from the cartridge.
7. Pin extracted.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
RELEASING THE DRUM SHUTTER FROM THE HOPPER
8. Using a scriber or small screwdriver, push the drum shutter
toner hopper tab out from its housing on one side of the hopper.
9. Repeat the same procedure for the opposite side.
NOTES
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CARTRIDGE SEPARATION PROCEDURE
10. Insert a flat screwdriver in the area shown between the two
sections of the cartridge and pry them apart.
11. Pry the sections out far enough to grasp within your hands.
REMOVING THE TENSION SPRINGS
12. Remove the tension spring on the side of the cartridge as
shown.
13. Repeat the same procedure on the other side of the cartridge.
Note: Spring tabs are very fragile and will recommend caution
when installing or removing them in a difference manner.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
14. With the springs removed, carefully separate the two sections as shown.
ABOUT THE ELECTRICAL CONTACT
15. If undue force is applied during the removal of the metal pin
and without concern for the integrity of the electrical contact
(shown) it can be rendered useless.
NOTES
16. Cartridge sections shown side by side.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
RELEASING THE DRUM SHUTTER FROM THE DRUM UNIT
17. Unhook the drum shutter from its support tab on one side of
the drum unit.
18. Repeat the same procedure on the opposite side.
CUT
19. Drum shutter completely removed.
DRUM REMOVAL PROCEDURE
20. To replace the drum and to reach other components, it is
necessary to actually cut off the non-contact plastic spindle
shown.
Use a scriber or small flathead screwdriver to push the drum
away to avoid damaging the end cap during cutting.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CUTTING THE OPC
21. Using a hacksaw, begin cutting the non-contact spindle
halfway only.
22. Rotate drum 90º counter-clockwise midway the cut to avoid
going too deep and damage components.
23. The drum can now be removed.
24. Drum shown with spindle severed off.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
2
1
REMOVING THE OPC
25. Carefully lift the drum from the right side shown and slide it
out.
26. Push in the sawed-off spindle out through the end cap as
shown.
NOTES
27. Spindle removed.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
REMOVING & CLEANING THE PCR
28. Using a pair of needle-nose pliers, pull the PCR out from one
side as shown.
29. Then slide it out
NOTES
30. Clean with a small amount of water and mild soap in case of
contamination, otherwise use a simple dry pad.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
DISASSEMBLING THE WIPER BLADE
31. Disassemble the blade by removing the two phillips screws
that hold it in place.
32. Be careful not to crease or damage the PCR contact strip
attached.
33. Use a scriber or flathead screwdriver to pry the wiper blade
assembly from its adhesive seal.
34. Lift the wiper blade out from one side and to the next.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CLEANING THE WIPER BLADE ASSEMBLY
35. Clean the wiper blade with a dry, lint-free cotton pad.
CLEANING THE WASTE HOPPER
36. Use a vacuum to clean the waste bin. This will allow you to
re-use the OEM adhesive.
Avoid using compressed air to keep the toner from scattering
and disrupting the purpose of the OEM adhesive seal.
ASSEMBLING THE WIPER BLADE
37. Install the clean wiper blade assembly and tighten with the
two Phillips screws.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
TESTING THE WIPER BLADE CONTACT
38. Check the electrical continuity with a Tester to ensure good
contact of the wiper blade frame against main contact.
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CLEANING THE PCR CONTACT STRIP
39. Remember to clean the PCR contact strip and PCR saddles
where residual toner may still be present.
40. Using a cotton tip swab, clean the edges and underlining of
the PCR blade.
CLEANING THE PCR SADDLES
41. Use a cotton tip swab to clean the PCR saddles to remove
residual toner.
42. Apply a small amount of isopropyl alcohol for best results.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
43. Apply a small amount of conductive grease onto the black
PCR saddles on both sides. Do not over-lubricate.
ASSEMBLING THE PCR
44. Install the PCR by sliding it into the saddle on one side then
lowering it onto the other saddle using a pair of needle-nose pliers.
NOTES
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
INSTALLING THE NEW OPC DRUM
45. A new covered OPC drum with pre-inserted drive/contact
spindle and a separate non-contact spindle (shown) is required
for this procedure.
46. First, lubricate the blue axle housings with a minimum
amount of white bearing grease.
47. Carefully slide the drum with its drive/contact spindle into
the axle housing on the left as shown.
48. Lower the opposite end of the drum into place as shown.
Align flange with the axle attachment.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
Insert the non-contact spindle (shown) into the housing.
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
49. The next step is fitting the pieces together using a phillips
screwdriver.
50. Close-up of axle housing.
51. Rotate the spindle back and forth to align it with the OPC.
52. The final step in assembling the drum unit is to install the
drum shutter. You can choose to unwrap the newly installed
drum now and complete this process, or keep the drum covered
and continue with the disassembly and cleaning of the developer unit.
Once it is aligned, push inward until the spindle locks.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
DISASSEMBLING THE DEVELOPER UNIT
REMOVING THE CONTACT PLATE
53. Unscrew the two phillips screws shown to remove the contact side end-plate.
54. Carefully separate the contact plate assembly from the
developer unit while keeping the contoured contact (shown) from
being distorted, especially at the point of separating it from the
pillar.
55. Contact plate removed with contoured contact shown intact.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
57. Separate plate carefully.
REMOVING THE GEAR-SIDE END PLATE
56. Unscrew the two phillips screws shown.
Drive Coupling
Main Drive
Hopper Gear
Dev Roller
Feeding Roller
POSITIONING THE GEARS
58. Note the position of all the gears shown.
www.uninetimaging.com
REMOVING THE DEVELOPER SLEEVE
59. After removing the gears, slide out the developer sleeve without damaging the mylar blade -- not the doctor blade beneath.
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
DEVELOPER SLEEVE MAINTENANCE
60. Secure the two bushings and clean the developer roller with
compressed air. Alternate with a lint-free cotton pad. Be sure to
clean the two bushings thoroughly.
REMOVING THE DOCTOR BLADE
61. Remove the blade assembly by unscrewing both phillips
screws on both ends of it.
62. Lift doctor blade carefully.
DOCTOR BLADE MAINTENANCE
63. Clean the working edge with a soft pad. Be aware that the
working edge is made of coated steel which can be damaged by
cleaning with solvents or applying excessive pressure.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
CLEANING THE FEEDING ROLLER & HOPPER
64. Note that the feeding roller cannot be taken out.
65. Vacuum the toner from the roller and from the hopper.
Secure foam seal at each end.
REFILLING THE TONER HOPPER
66. Refilling can be done thru the opening in the mag roller and
the space on top of the feeding roller. Use a 12mm beak in the
bottle and load the proper toner volume.
ASSEMBLING THE DEVELOPER ROLLER
67. Reinsert the bushings on each end of the developer roller
shown and slide into place.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
68. Apply a very small amount of conductive grease in the contacts ends, then install the contact plate with the two phillips
screws.
ASSEMBLING THE DOCTOR BLADE
69. Fit Doctor Blade assembly into place.
NOTES
70. Tighten screws at both ends.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
JOINING BOTH SECTIONS: METAL & PLASTIC PINS
71. Join both sections aligning the pin insertion points.
72. Insert the plastic pin by hand mid way.
Insert the metal pin back into place until a click is heard.
73. Then drive it home with a small hammer.
www.uninetimaging.com
74. Section assembly is complete.
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
OEM CHIP REMOVAL PROCEDURE
75. Locate the OEM chip at the rear of the hopper.
76. Using an X-Acto knife, carefully cut away the melted plastic
tabs above the chip that anchor it into place.
77. Slide the blade beneath the base of chip and begin lifting it
up carefully, sliding it out through the slotted housing as shown.
78. OEM chip removed.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
UNINET IMAGING INC. • HP 2600 CARTRIDGE REMANUFACTURING INSTRUCTIONS
REPLACING THE CHIP
79. Apply a small amount of plastic cement into the slots near
the broken tabs shown. This will seal the sides of the replacement chip into place. NOTE: Be careful not to apply so much glue
that would cover up the contacts rendering the chip useless.
80. Insert the new chip into the slots with the golden contact
position shown.
81. New chip inserted.
82. Allow the cement to dry before testing the cartridge.
RECYCLING TIP: UniNet Mag Roller Coating Solution extends the life of the mag roller sleeve by applying a coating of Teflon and sealants
to the transfer layer of the mag roller sleeves.
This coating fills in surface scratches and provides much-needed lubrication to the sleeve to prevent wear that can lead to mag roller
sleeve failure.
HOW TO APPLY:
• FIRST, pre-clean the mag roller sleeve with a lint free cloth. The cloth should remove toner and surface contaminants from the sleeve.
• SHAKE WELL. Apply a few drops of mag coating solution to a cotton pad. It must be a lint-free pad!
• Apply mag coating solution in a back and forth circular motion along the axis of the mag roller sleeve. Go around the sleeve at least two
times, applying a thin, even coat
• Allow to dry for 3 to 5 minutes. A haze should appear. Remove the haze from the sleeve with a clean cotton pad.
Replace the mag roller sleeve in the cartridge. You have successfully completed the process.
www.uninetimaging.com
USA
Ph: +1 310-280-9620
Fx: +1 310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
JAPAN
+81-3-44-55-2789
+1 310-838-7294
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4571-2388
+54-11-4574-3706
11124 Washington Blvd., Culver City, California U.S.A. 90232 • techsupport2@uninetimaging.com
All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
© 2006 Uninet Imaging Inc.
Download PDF
Similar pages