Toyama
Gel Deep Cycle Battery
NPS100-12 [12V100AH]
Specification
Nominal Voltage
12V
Nominal Capacity(10HR)
100AH
Dimensions
Length
Width
Container Height
Total Height (with Terminal)
Approx Weight
Terminal
Approx 30.0kg (67.02lbs)
Container Material
ABS
Rated Capacity
104.0 AH/5.20A
100.0 AH/10.0A
88.0 AH/17.6A
76.2 AH/25.4A
63.8 AH/63.8A
331 2mm (13. 0 inches)
174 2mm (6.81 inches)
214 2mm (8.35 inches)
219 2mm (8.66 inches)
T4 (M8X16) / Torque: 6.6 ~ 8.3Nm
0
0
(20hr ,1.80V/cell,25 C/77 F)
0
0
(10hr,1.80V/cell,25 C/77 F)
0
(5hr,1.75V/cell,25 C/77 0F)
0
0
(3hr,1.75V/cell,25 C/77 F)
0
0
(1hr,1.60V/cell,25 C/77 F)
Applications
Solar or Wind Power System
Stored energy (Photovoltaic)
Uninterruptable Power Supply (UPS)
Max. Discharge Current
1200A (5s)
Internal Resistance
Approx 4.0m Ω
Electric Power System (EPS)
Emergency backup power supply
o
o
Discharge : -15 50C (5 122F)
Charge
: 0 40C (32 104F)
Storage : -15 40C (5 104F)
o
o
Operating Temp.Range
25
Railway signal
o
o
Operating Temp. Range
Emergency light
o
o
3C (77
5F ) but can work in -15
o
50C (5
o
122 F)
Aircraft signal
Initial Charging Current less than 30.0A.Voltage
Cycle Use
0
Standby Use
Alarm and security system
0
14.4V~15.0V at 25 C(77 F)Temp. Coefficient -30mV/0C
Electronic apparatus and equipment
No limit on Initial Charging Current Voltage
Communication power supply
0
0
0
13.5V~13.8V at 25 C(77 F)Temp. Coefficient -20mV/ C
o
DC power supply
o
40 C (104 F)
103%
o
o
100%
25 C ( 77 F)
o
o
86%
0 C
( 32 F)
NP S series of batteries may be stored for up to 6 months
0
0
at 25 C(77 F) and then a freshening charge is required.
For higher temperatures the time interval will be shorter.
Capacity affected by
Temperature
Self Discharge
Germany
tested
ISO9001 ISO14001
o
o
Constant Current Discharge (Amperes) at 25 C (77 F )
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
173.6
146.4
130.2
115.3
87.5
65.2
52.4
31.3
23.5
19.2
16.4
14.4
11.6
9.65
5.13
1.80V/cell
210.0
167.6
143.7
123.5
92.1
68.7
55.1
33.1
24.6
20.2
17.2
15.0
12.0
10.0
5.20
1.75V/cell
237.0
186.3
154.0
130.8
96.5
71.3
57.1
34.4
25.4
20.7
17.6
15.3
12.2
10.1
5.29
1.70V/cell
261.6
199.5
165.1
138.9
101.8
74.6
59.5
35.3
26.0
21.2
17.9
15.6
12.4
10.2
5.34
1.65V/cell
291.7
215.1
178.5
146.6
106.7
77.4
61.9
36.3
26.7
21.7
18.3
15.9
12.6
10.3
5.40
1.60V/cell
330.8
232.5
188.5
154.3
112.3
80.5
63.8
37.5
27.6
22.2
18.6
16.2
12.7
10.5
5.45
o
o
Constant Power Discharge (Watts/cell) at 25 C (77 F )
F.V/Time
5min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
322.5
10min
274.9
247.1
220.5
168.5
126.4
102.2
60.8
45.7
37.5
32.2
28.2
22.9
19.1
10.2
1.80V/cell
386.4
312.2
271.0
235.1
176.8
132.7
107.2
63.8
47.7
39.2
33.6
29.4
23.7
19.8
10.3
1.75V/cell
431.3
344.9
288.7
247.8
184.3
137.3
110.8
66.0
49.1
40.1
34.3
29.9
24.0
19.9
10.4
1.70V/cell
470.9
366.5
307.7
261.8
193.6
143.0
115.0
67.6
50.1
41.0
34.8
30.4
24.3
20.1
10.5
1.65V/cell
519.3
391.4
330.2
274.5
201.9
147.7
119.1
69.2
51.3
41.8
35.3
30.8
24.6
20.3
10.6
1.60V/cell
578.9
418.2
345.1
286.6
211.1
152.9
122.4
71.1
52.7
42.6
35.9
31.3
24.8
20.5
10.7
1
Toyama
Gel Deep Cycle Battery
NPS100-12 [12V100AH]
Dimensions
T 4 Terminal
Unit: mm [inches]
18 [0.7 08 ]
M8 [0.315]
331
Discharge Characteristics
12 V
Battery
V
2
Float Charging Characteristics
0
0
Te mpera ture :25 C(77 F)
13.0
Charging Charging
Current Voltage
Charge
Volume
%
12. 0
temperature250C
0.10CA-2.25V/cell
(V)
(XCA)
0.25
120
110
11.0
0.1C 0.0525C
0.4C
10.0
1C
9.0
100
90
80
0.205C
0.6C
40
30
8.0
2C
2
4
6
8 10
20
40
60
2
6 8 10
4
20
10
0
20
H
Min
Charged Volume
14.0
Charge Voltage
(Constant 2.25v/cell)
0.15
13.0
70
60
50
1
15.0
0.20
0.10
After 50% Discharge
12.0
After 100% Discharge
0.05
11.0
Charging Current
0
0
4
8
Discharge Time
16
12
20
28
24
32
36
40
Charging Time(hours)
Effect of Temperature on Long Term Float Life
Temperature Effects in Relation to Battery Capacity
120
10
8
6
5
4
3
0.1CA
0.17CA
100
0.25CA
80
60
Charging voltage :
2.25V/cell
2
40
1
20
0.5
-20
-10
0
10
20
30
40
50
20
68
60
30
86
40
104
50
122
0
C
F
O
Battery temperature
0
Temperature(C)
Cycle Life in Relation to Depth of Discharge
Self-discharge Characteristics
Te st in g co n di ti on
D i sc ha rg i ng : c urr en t 0 . 1 7 C ( FV 1 . 7 V/ ce l l );
C h ar gi n g : cu rr en t 0 . 25 C ma x, vo lt a g e 2 . 4 5 V /ce l l ;
C h ar gi n g vo l ume: 1 2 5% o f d i sch a rg ed c ap ac i t y.
100
0
10 C
80
A
250 C
120
B
60
100
40
80
300 C
40 0 C
C
20
60
40
100%
DOD
50 %
DOD
A
5 00
100 0
1500
2000
25 00
30 00
B
N umber of C yc les
C
Specifications subject to change without prior notice.
2
4
6
8
10
12
Storage Time(Months)
Ambient Termperature:
o
25oC (77 F)
20
0
0
0
30 %
DOD
No supplementary charge required.
(Carry out supp lementa ry charge before use if 100% capacity is required.)
Supplem entary c harge re quired b efore us e.Optional charging way as below:
1.Charg ed for above 3 days at limted current 0.25CA and constant volatge 2 .25V/cell.
2.Charg ed for above 20 hours at limted current 0.25CA and constant volatge 2 .45V/cell.
3.Charg ed for 8~10 hours at limited current 0.05CA .
Supplem entary charge may often fail to recover the capacity.
The battery sho uld nev er be left standing till this is reached.