Voice Processor 2x
Next generation two channel programmable Voice Processor for today’s broadcast professional.
The microphone is a crucial link to the audience.
Proper management of that link is essential.
Enter the Voice Processor 2x, an outstanding
programmable microphone processor that is flexible,
powerful, and easy to use.
Chief Engineers treasure its programmability and
rich DSP feature set. On-air talent enjoy its simplicity
of operation. Studio managers appreciate how it
independently processes two microphone channels
in one rack space. And, most importantly, everyone
loves the sound – including the listening audience.
The 2x offers a comprehensive set of voice
enhancement tools for any situation. The 2x’s
Windows® software application enables total control
of all essential parameters. Once a desired sound is
dialed in, all settings are saved as named presets for
later recall from the front panel or remotely. Any mic
can be optimized for a diverse air staff with either
male or female voices.
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
Our Voice Processor legacy began with the original
model 528, and has continued through the 601,
528E, 628 and 6200. Now you can maintain quality
assurance throughout your voice talent signal chains
with the Voice Processor 2x, Engineered by Symetrix.
Our name has become synonymous with high quality
audio processing for over 40 years.
Features
• Two (2) independently programmable
channels of ultra-low latency digital
microphone processing in one rack space.
• Two (2) Mic/Line inputs, two (2) Mic/Line
outputs, two (2) AES3 outputs, Word
Clock input.
• Processing modules include Compression,
Equalization, De-Essing, Downward
Expansion, Highpass and Lowpass filters,
and Voice Symmetry.
• Configure named presets for each on-air
personality – up to 50, including factory
presets – using the included Windows®
software over Ethernet.
• Recall presets with convenient front panel
controls, optional hardware remote(s), or
third-party control protocol.
Voice Processor 2x
A&E Specifications
Performance Data
Mechanical Data
The device shall provide two inputs that are selectable as line or mic level
with phantom power and four outputs (two line level analog and two AES3
digital). All signal processing (including input gains) shall be controllable via
software. Audio inputs and outputs shall be accessed via rear panel XLR
connectors.
INPUTS
Space Required:
1U (WDH: 48.02 cm x 23.11 cm x 4.37 cm / 18.91 in
x 9.1 in x 1.72 in), depth is specified from front panel
to back of connectors.
Allow at least 3 inches additional clearance for rear
panel connections. Additional depth may be required
depending upon your specific wiring and connections.
The Graphical User Interface (GUI) software shall be installer programmable
using the Windows® XP or Vista operating system. Computer connection
and control shall be via the device’s rear panel Ethernet connector. The GUI
shall provide display and control of all signal processing and configuration
functions including, but not limited to: Input and Output Gain, Highpass
Filtering, Lowpass Filtering, De-essing, Downward Expansion,
Compression, Parametric Equalization, Signal Routing, Voice
Symmetry and Polarity.
The front panel shall include input and output level indication as well as
indicators for POWER, NETWORK, and REMOTE. Additionally, a front panel
LCD shall display certain system parameters and may be used for preset
recall via the front panel UP, DOWN and MENU buttons.
External control shall include preset selection and/or comprehensive
parameter adjustment, depending upon the particular remote in use, and
shall be via industry-standard CAT5 cable with RJ45 connectors to the front
or rear panel REMOTE ports. All program memory shall be non-volatile and
provide program security should power fail. 3rd party control systems may
interface via Ethernet using a published Control Protocol.
Audio conversion shall be 24-bit, 48 kHz with configurable output sample
rate. The dynamic range of the processor shall not be lower than 113 dB
A-weighted.
The device shall have an IEC power input socket. The device shall meet
UL/CSA and CE safety requirements and comply with CE and FCC Part
15 emissions limits. The device shall be RoHS compliant. The chassis shall
be constructed of cold rolled steel and moulded plastic, and mount into a
standard 19” 1U EIA rack. The device shall be an model Voice Processor
2x, Engineered by Symetrix.
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
Nominal Input Level: +4 dBu or -10 dBV line level, to -50 dBu mic level
(software selectable) with 20 dB of headroom
Maximum Input Level: +23 dBu
Input Impedance: 6.67 kΩ balanced, > 3.3 kΩ unbalanced
CMRR: > 75 dB @ 1 kHz, unity gain
Mic Pre-amp EIN:> -127 dB, 22 Hz - 22 kHz, 100 Ω source impedance
Phantom Power: +48 VDC
A/D Conversion: 24-bit delta/sigma
A/D Dynamic Range: 116 dB (A-Weighted)
A/D THD+Noise: -102 dB (un-weighted); 1 kHz @ -2 dBFS with 0 dB gain
A/D Latency: 0.25 mS
OUTPUTS
Nominal Output Level:
Analog: +4 dBu line level with 20 dB of headroom
Digital: -20 dBFS. For unbalanced analog output, float (do not connect) the
minus output terminal. Unbalanced usage results in 6 dB lower output level.
Maximum Output Level:
Analog: +24 dBu. Digital: 0 dBFS
Output Impedance:
Analog: 200 Ω balanced, 100 Ω unbalanced. Digital: 110 Ω
D/A Conversion: 24-bit delta/sigma
D/A Dynamic Range: 114 dB (A-Weighted)
D/A THD+N: -98 dB (un-weighted); 1 kHz @ -2 dBFS
D/A Latency: 0.2 mS
Mic Level Output Pad (Internal): -42 dB
SYSTEM
Nominal Sampling Rate: 48 kHz
Word Clock Input Range: 22 - 192 KHz
A/D/A Frequency Response: 20 Hz - 20 kHz, +/- 0.25 dB
A/D/A Dynamic Range: 113 dB (A-Weighted)
A/D/A Latency: < 0.7 mS; with all DSP active
Interchannel Crosstalk: > -90 dB @ 1 kHz, typical
Electrical:
100-240 VAC, 50/60 Hz, 25 Watts maximum.
No line voltage switching required.
Ventilation:
Maximum recommended ambient operating
temperature is 30 C / 86 F. Ensure that the left and
right equipment sides are unobstructed (5.08 cm, 2
in minimum clearance). The ventilation should not be
impeded by covering the ventilation openings with
items such as newspapers, tablecloths, curtains, etc.
Certifications: UL 60065, cUL 60065, IEC 60065, EN
55103-1, EN 55103-2, FCC Part 15, RoHS
Weight: 8 lbs. (3.60 kg)