GENERAL INSTRUCTIONS FOR CERAMIC DISC CARTRIDGE

NF
24-4-2015
GENERAL INSTRUCTIONS FOR CERAMIC DISC CARTRIDGE REPLACEMENT
Metal Lever Handle
2 Grub Screw
1
3 Dress Ring
Red & Blue
Water Indicator 2. Insert the allen key supplied into
4 Lock Nut
5 Ceramic Disc Cartridge
Main Body & Outer Casing
6
Teflon Washer
Rubber
O Rings
NOTE: Please turn off water supply
at the stop taps or water meter.
1. To replace the cartridge, follow
the step by step instructions.
Remove the blue/red indicator (1).
the grub screw (2) and turn it anticlockwise. Once the screw is
loose, the handle can then be
pulled in the up-ward direction.
3. Remove the chrome Dress Ring (3)
by hand in the anti-clockwise
direction.
4. Use an appropriate spanner to
undo the brass lock nut (4) in the
anti-clockwise direction.
Rubber
Washer
Spout
Aerator
5. Pull the square post upwards to
remove the cartridge (5).
6. Use a dry cloth to dry up any
water inside the tap body (6)
Teflon Washer
Base Dress Ring
Project sink mixer is illustrated
7. Insert the new cartridge making
sure the two locators at the
bottom of the cartridge seat inside
the tap body (6)
8. Replace brass lock nut (4) and
tighten until it is firm not overtight.
9. Replace Dress Ring (3) and hand
tighten.
10. Replace Handle and tighten
grub screw (2) then push the
blue/red indicator (1) back into
the hole.
Now you have finished. Turn back on
the water supply and observe for
any leaking.
Water pressure must not exceed 500kpa or warranty is void.