Cancer Alert System (CAS) Requirements
Below is a listing of the items you will need to host the Cancer Alert System (CAS) automated casefinding system
at your facility to send potential cases into CNEXT. The Cancer Alert System (CAS) can currently receive HL7
message feeds of BAR, ADT, or ORU messages from multiple departments such as pathology, hospital
admit/discharge (BAR preferred), radiation oncology and radiology imaging.
CAS Listener Workstation
•
Intel Dual Core (i3, etc.) or Xeon CPU or better, 1.2GHz or better, 1 GB RAM or more *
* (equivalent processors, such as those from AMD, may also work, but have not been
tested)
•
200 mb available hard drive space
•
Windows 7, Windows 8, Windows 8.1
Windows Server 2003 R2, Windows Server 2008, Windows Server 2008 R2, Windows Server
2012, Windows Server 2012 R2
•
DVD or CD drive (optional installation media)
•
Backup hardware and software (recommended daily backups of CAS database)
•
Fixed IP address for HL7 router
•
Video card and monitor capable of displaying 800 x 600 or better
•
Physical location recommended in IT or in the Cancer Registry office
Note: Must be on 24/7 to receive and queue messages. User does not have to be logged on. A dedicated
workstation or server is not required and may be virtualized.
CAS MessageQ Database
•
MS SQL Server 2005, SQL Server 2008, SQL Server 2008 R2, SQL Server 2012, (SQL Server
2014 *not yet tested)
•
Server need not be dedicated to CAS
•
15 GB available hard drive space for database and log files
•
SQL Server need not contain the CNExT databases also, but it can
•
SQL Server need not be on the CAS Workstation, but it can be
•
Backup hardware and software (recommended daily backups of CAS databases)
Note: Must be on 24/7 to record messages. Server may be virtualized. The CAS Workstation must be able to
access the SQL Server machine for CAS (MessageQ) database and the SQL Server machine for the CNExT
databases (if a different SQL Server).
Revised: May 18, 2017
BAR or ADT Message Requirements
•
Messages in HL7 format 2.1 or higher
•
BAR^P01 or ADT^A08 message type/trigger event (BAR preferred)
•
Messages must contain a facility wide unique identifier (called Medical Record in the CNExT
case database) for matching messages to the CNExT database
•
MSH-9.1, MSH-9.2, MessageType and TriggerEvent fields must be filled with legitimate values
•
MSH-10, MessageControlID fields must be filled with legitimate values
•
At least one DG1-3.1, DiagnosisCode, field MUST be present and filled with a valid ICD-9 or
ICD-10 diagnosis code for determining if the message is or is not cancer related; (multiple DG1
segments, therefore multiple diagnosis codes, are allowed)
•
A DG1 field must be filled with values to indicate ICD coding system (ICD-9 or ICD-10)
ORU Message Requirements
•
Messages in HL7 format 2.1 or higher
•
ORU^R01 message type
•
Messages must contain a facility wide unique identifier (called Medical Record in the CNExT
case database) for matching messages to the CNExT database
•
MSH-9.1, MSH-9.2, MessageType and TriggerEvent fields must be filled with legitimate values
•
MSH-10, MessageControlID fields must be filled with legitimate values
•
At least one OBX-5, ObservationValue, field MUST be present and contain legitimate text that
the software can evaluate for cancer; (multiple OBX segments are allowed)
Revised: May 18, 2017