LED Flood EX 21 User Manual

LED Flood EX 21
User Manual
1
LED Flood EX 21
www.showtech.com.au
Table of Contents
1. Safety instructions…………………………………………………………3
1.1 Power Connection ………………………………….……………….4
1.2 Overhead Rigging …………………………………………………...4
1.3 DMX Connection ……………………………………………………..6
1.4 Cleaning and Maintenance ………………………………………6
2. Menu Navigation .…………………………………………………………7
3. DMX Allocation….………………………………………………………….9
4. Technical Specifications ……………………….……………………….12
2
LED Flood EX 21
1. Safety Instructions
FOR SAFE AND EFFICIENT OPERATION
Be careful with heat and extreme temperature.
Avoid exposing it to direct to rays of sun.
Operate only between 41°F/5°C and 95°F/35°C.
Keep away from humidity, water and dust.
Do not place the use in a location with high humidity or lots of dust.
It is ideal to use the Hercules away from such equipment:
Transformer motor, tuner, TV set and amplifier.
Avoid placing on un-stable location
Select a level and stable location to avoid vibration.
Do not use chemicals or volatile liquids for cleaning
Use a dry cloth to wipe off dust, or a wet soft cloth for stubborn dirt.
NO USER SERVICABLE PARTS INSIDE.
If unit is out of service, please contact your point of purchase.
If any troubles arise, remove the power plug and contact your ShowPro
representative for repair. Do not open the machine by yourself, it might result a
danger of electric shock.
Take care with the power cable. Never pull the power cable to remove the plug from
the receptacle, be sure to hold the plug.
3
LED Flood EX 21
When not using the unit for an extended period of time be sure to disconnect the
plug form the receptacle.
1.1 Power Connection
AC Power This product has an auto-ranging power supply that can work with an
input voltage range of 100–240 VAC
AC Plug
Connection
AC Live
AC Neutral
AC Ground
Wire
Brown
Blue
Green/Yellow
1.2 Overhead Rigging
This item must be built in a way that it can hold 10 times more of its weight for 1
hour without causing any damage. The installation must be secured with a secondary
safety attachment. The Safety attachment has to be constructed in a way that no
part of the installation can fall. When rigging, de-rigging or servicing the fixture
ensure that the area below is secure. Before putting the device into operation, the
installation must be approved by an expert. The operator has to make sure that
safety-relating and machine-technical installations are approved by a skilled person
once a year.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE.
Including (but not limited to) calculating working load limits, installation material
being used, and periodic safety inspection of all installation material and the
projector. If you lack these qualifications, do not attempt the installations yourself,
but instead use a professional structural rigger. Improper installation can result in
bodily injury and/or damage to property.
4
LED Flood EX 21
Use only professional trussing system if the item is to be lowered from the ceiling or
high joists. Never let the device swing freely in a room.
CAUTION: Overhead Items may cause serious injuries when not installed correctly!! If
there is concern about the safety DO NOT INSTALL the device.
DANGER OF FIRE!
When installing the device, make sure there is no highly-flammable material
(decoration articles, etc.) within a distance of min. 0.5m.
Mount the projector with the mounting bracket to your trussing system using an
appropriate clamp.
For overhead use, always install a rated safety - wire that can hold at least 10 times
the weight of the fixture. You must only use rated safety – wire with quick links with
screw cap. Pull the rated safety - wire through the hole in the mounting bracket and
over the trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw. The maximum drop distance must never exceed 20cm
A safety - wire which has already held the strain of a fall or which is defective must
not be used again.
IMPORTANT!
Before taking into operation for the first time, the installation has to be approved by
an expert.
5
LED Flood EX 21
1.3 DMX Connection
DMX Linking the LED Flood EX 21 will work with a DMX controller using a 5-pin DMX serial
connection.
DMX Connection the LED Flood EX 21 uses IP Rated 5-pin DMX data connections for its DMX
personalities:
4 Ch, 6 Ch, 10Ch. See the User Manual for information about connecting and configuring the
product for DMX operation.
1.4 Cleaning and Maintenance
Please make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
1.
2.
3.
Make sure before installing that all screws are tightly connected and not corroded.
There must be no deformations on the housings, fixations and installations spots
Any defects on the electronics, power cables or housing must be repaired for safe
use.
If the exterior of the unit is going to be cleaned, please use moist, lint free cloths. Never use
alcohol or solvents.
The Cooling fan must be cleaned monthly and check to ensure it is free of obstructions.
To clean the interior of the device please use a vacuum cleaner or an air jet, however we
recommend cleaning the lenses weekly to ensure the best output from your unit.
6
LED Flood EX 21
6
S
-
-
S
Program Speed
U
-
-
S
1
1
0
0
r
Custom Color Mixing
0
2
5
5
g
0
2
7
5
5
b
0
2
5
I
Dimmer Speed Mode
8
9
10
t
P
e
A
M
S
0
2
5
5
O
F
F
d
I
M
1
d
I
M
2
d
I
M
3
M
(Default:
R/G/B/W=255)
5
W
d
(Default:S100)
Dimmer speed OFF: (
Default:OFF)
Dimmer
speed
Mode1(Fast)
Dimmer
speed
Mode1(Middle)
Dimmer
speed
Mode1(Slow)
P
S
O
n
O
F
To unlocking, please
press”
UP-DOWN-UPDOWN-ENTER” step by
step; If the password
input is wrong, please
press ”ENTER” to input
again.
F
8
LED Flood EX 21
8
9
10
Auto
programs
Auto speed
Dimmer
speed
mode
091-110
111-130
131-150
151-170
171-200
201-205
206-210
211-215
216-220
221-225
226-230
231-235
236-240
241-245
246-250
251-255
000-051
052-101
102-152
153-203
204-254
255
000-255
R 0~100% G 0
B 100%
R 100% G 0
B 100%~0
R 100% G 0~100% B 0~100%
R 100%~0 G 100%~0 B 100%
R 100% G 100% B 100% W:100%
White1
White 2
White 3
White 4
White 5
White 6
White 7
White 8
White 9
White 10
White 11
No Function
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5
Auto programs speed slow to fast
000-051
Preset dimmer speed from display menu
052-101
102-152
153-203
204-255
Dimmer speed mode off
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
10
LED Flood EX 21
4.0 Technical Specifications
OPTICS
LED Specification
LED quantity
Field Angle
Beam Angle
Output
8W RGBW 4 in 1 LEDs
21
76.6°
39.84 °
Control
Control method
WDMX Compatibility
DMX Channels
Dimming Curves
Dimming Resolution
Data Connections
Menu
DMX
N/A
4,6 and 10
4 Modes
16 bit
5 Pin IP Rated connectors
Touch Screen
Electrical
Power
Battery Specifications
Working Hours
Charging hours
Charging
Charging during use
Input Voltage AC
Power Consumption
Fuse
240V IP Rated connectors
N/A
N/A
N/A
N/A
N/A
100V-240V AC 50/60 Hz auto-ranging
144W
N/A
11
LED Flood EX 21
Physical
Weight
Size
Cooling System
IP Rating
9.18Kg
482 x 266.5 x 175.6 cm
Fan-free convection cooled
IP65
12
Download PDF
Similar pages