Installation & Maintenance Manual
Digital Pressure Switch
Series ZSE30/ISE30
Safety Instructions
The Digital Pressure Switch and this manual contain essential
information for the protection of users and others from possible
injury and property damage and to ensure correct handling.
Please check that you fully understand the definition of the following
messages (signs) before going on to read the text, and always
follow the instructions.
IMPORTANT MESSAGES
Read this manual and follow its instructions. Signal words such
as WARNING and NOTE, will be followed by important safety
information that must be carefully reviewed.
Indicates a potentially hazardous situation
which could result in death or serious injury
if you do not follow instructions.
Specification
Safety Instructions (continue)
• Insert a noise filter (line noise filter, ferrite element or other element)
between the switching regulator and pressure switch when analog
output is used.
• Do not use with a corrosive or inflammable gas or liquid.
• Do not press the setting buttons with a sharp pointed object.
• Turn power on for 20 to 30 minutes before detecting fine pressure.
Initial drift of about ±1% occurs immediately after turning the power on.
• The direct-current power supply to combine should be a UL
authorization class 2 power supply based on UL1310, or a power
supply using a transformer which is class 2 based on UL1585.
• Only a pressure switch with UL mark on the body is UL approved.
• This pressure sensor is for use with air only. Please contact SMC if
the switch is to be used with other fluids.
Series
ZSE 30 (Vacuum, Low Pressure)
Rated Pressure Range
Set Pressure Range
Withstand Pressure
Minimum Display Unit
Applicable Fluid
Temperature Characteristic
Enclosure
Ambient
Temperature Range
Ambient Humidity
Range
Environmental Resisitance
ZISE##-TFI48GB-A
For one-touch fitting type:
• Do not apply unnecessary forces such as twisting, pulling, moment
loads, etc. on fitting or tubing.
• When using a brand of tubing other than SMC, be careful of the
tolerance of the tube’s O.D.
1) Nylon tube ±0.1mm
2) Soft nylon tube ±0.1m
3) Polyurethane tube +0.15mm, -0.2mm
Withstand Voltage
Insulation
Resistance
Vibration proof
Impact proof
Standards
One-touch Fitting
Strait Type
One-touch Fitting
Elbow Type
Weight
Follow the instructions given below when handling the pressure
switch.
Otherwise, the switch may be damaged or may fail, thereby
resulting in malfunction.
• Do not drop, bring into collision with other objects or apply
excessive shock to the unit (100m/s2 or more).
• Do not pull the lead wire with force or lift the main unit by holding
the lead wire. (Pulling strength less than 35N)
• Do not insert wire or other articles into the pressure port.
• Connect wires and cables correctly.
• Do not perform wiring while power is on.
• Do not wire with power cable or high-voltage cable in the same wire
route.
• Connect Terminal FG to ground when using a switching regulator
obtained on the commercial market.
T1
-
-
-
-
C4H C6H N7H C4L
-
-
4mm
5/32inch
6mm
-
Response Time
Short Circuit Protection
Repeatability
Voltage
Output
(See NOTE 2)
Analog
Output
-
1/4inch
-
-
ZSE
For Vacuum or Low Pressure
-
-
-
Display Method
-
-
-
Display Accuracy (at 25oC)
Indication Light
4mm
5/32inch
6mm
1/4inch
76g
78g
38g
40g
01
R1/8 (M5 female thread)
T1
NPT1/8 (M5 female thread)
One-touch fitting Ø4mm,Ø5/32inch
C6H
One-touch fitting Ø6mm
N7H
One-touch fitting Ø1/4inch
C4L
One-touch fitting Ø4mm, Ø5/32inch
Straight Type
NPN Output
65
PNP Output
26
1-5V Output
28
4-20mA Output
None
Bracket
A
Panel Mount Adapter
Lead Wire with
Connector(Length: 2m)
B
LCD Display
Indication Light
Panel Mount Adapter + Front Protection Cover
C6L
One-touch fitting Ø6mm
N7L
One-touch fitting Ø1/4inch
Units Specification
SI Units Only (Note 1)
M
Elbow Type
Set pressure range and Rated pressure range
Set the sensor pressure with the rated pressure range
"Set pressure range " means the pressure range that can be set.
"Rated pressure range" means pressure range that satisfies the product
specifications (accuracy, linearity, etc.)
Setting outside of the Rated pressure range could be set if the setting is within the
Withstand pressure range, but the specified performance is not always realized.
Pressure Range
Switch
For
vacuum or
Low
Pressure
For Positive
Pressure
-100kPa
ZSE30
ISE30
0
-100kPa
100kPa
500kPa
1MPa
100kPa
101kPa
-101kPa
0
1MPa
-100kPa
(-0.1MPa)
1MPa
Rated Pressure Range of a Switch
Set Pressure Range of a Switch
NOTE 1: Analog output cannot be selected when switch output is selected.
NOTE 2:Both switch output and current output cannot be selected simultaneously when
voltage output is selected.
NOTE 3:Both switch output and voltage output cannot be selected simultaneously when
current output is selected.
Indication Light : Displays switch operation condition.
(Green Light)
LCD Display : Displays the current status of pressure, setting mode,
selected indication unit and error code. Four display
modes can be selected: display always in red or green
only, or changing from green to red linked to output.
Button : Selects the mode or increases ON/OFF set value.
Press this button to change to the peak display mode.
Button : Selects the mode or decreases ON/OFF set value.
Press this button to change to the bottom display mode.
Button : Press this button to change to either mode and to set a
set value.
Option 2
No Symbol
No
25
3.5 digits 7-segment display, dual-color display
(red/green) Sampling rate: 5 times/ 1s
±2%F.S. ±2 digits
±2%F.S. ±1 digit
Lit when ON (Green)
Main Unit
Symbol
C4H
Variable(From 0)
Names and Functions of Individual Parts
No Lead Wire
Output Specification
No Symbol
ISE 30
12 to 24VDC, ripple (p-p) 10% or less
(Protected against inverse connection)
45mA or less (With no load)
NPN or PNP open collector output. 1 output
80mA
30V (During NPN output)
1V or less (at 80mA load current)
2.5ms or less (anti-chatter function working: 20, 160,
640 or 1280ms selectable)
Provided
±0.2%F.S. ±2 digits or less ±0.2%F.S. ±1 digit or less
Output Voltage:1 to 5V ±2.5%F.S. or less
(within rated pressure range)
Linearity:±1.0%F.S. or less
Output impedance: about 1k
Output Current: 4 to 20mA ±2.5%F.S. or less
(within rated pressure range)
Linearity:±1.0%F.S. or less
Maximum Load Impedance: 300 at power supply
voltage of 12V, 600 at 24V
Minimum Load Impedance: 50
Hyste- Hysteresis Mode
resis Window Comparator Mode
N7L
43g
-
Piping Specification
Current
Output
(See NOTE 3)
C6L
81g
Option 1
Otherwise It can cause failure or malfunction of the system.
NOTE
Current Consumption
Switch Output (See NOTE 1)
Maximum Load Current
Maximum Impressed Voltage
Residual Voltage
Oring:HNBR
Pressure sensing part: silicon, Piping port: C3602(Electroless nickel plated)
O ring: NBR
O ring: NBR, Fitting Part: PBT
Including lead wire
with connector (2m)
Excluding lead wire
with connector
ISE For Positive Pressure
Fire, malfunction or switch damage can result.
Do not use this product in a place where static electricity
is a problem.
30-
Pressure Range
Do not operate outside of the specification range.
Fire, an explosion and corrosion can result.
This pressure switch is not an explosion-proof type.
Power Supply Voltage
Model Indication Method
An injury or failure can result.
Do not operate in atmosphere of inflammable, an
explosive or corrosive gas.
01
R1/8
NPT1/8
M5 0.8 M5 0.8
Port Size
Material for Fluid
Contact
Do not disassemble, modify (including change of printed
circuit board) or repair.
ZSE 30
CE Marked, UL/CSA(E216656)
Piping Type
Gives you helpful information.
ISE 30 (Positive Pressure)
-100.0 to 100.0kPa
0.000 to 1.000MPa
-101.0 to 101.0kPa
-0.100 to 1.000MPa
500kPa
1.5MPa
0.001MPa
0.2kPa
Air, inert gases and Non-flammable gases
±2%F.S. or less (25ÞC reference)
IP40 (IEC60529)
Operation: 0 to 50ÞC, Storage:-10 to 60ÞC
(No condensation or freezing)
Operation·and Storage:35 to 85%RH
(No condensation)
1000VAC ,1 minute
(between live parts and case)
50M or more (at 500VDC M)
(between live parts and case)
10 to 150Hz, 1.5mm or 20m/s2 double amplitude,
2 hours each indirections of X, Y and Z
100m/s2, 3 times each in directions of
X, Y and Z respectively
Button
Button
Button
D
With Unit Selection Function (Note 2)
Note 1) Fixed Unit
For Vacuum, Low Pressure: kPa
For Positive Pressure: MPa
Note 2) Product with unit selection function cannot be
used in Japan due to new Measure Law issued.
Use the following product codes when optional items are needed as
separate products.
A
ZS-27-C
Length: 2m
Mounting Screw (M3x5L, 2 pcs)
M3x8L, 2 pcs attached
ZS-27-D
M3x8L, 2 pcs attached
D
Lead Wire with Connector
Bracket
Panel Mount Adapter
Panel mount Adapter + Front Protection Cover
Front Protection Cover
ZS-27-01
ZS-27-A
ZS-27-B
-
L
B
-
Outline with Dimensions (in mm)
Outline with Dimensions (continue)
ZISE##-TFI48GB-A
Dimensions of Main Unit
25
8 9.5
Lead wire with
3.6
30
20 0.1
10
01:R1/8
T1:NPT1/8
Details of Pipe Fitting Part
2-M3 0.5
Depth 4
Pipe Port
1.5
Panel mounting of adjacent switches
20 0.1
connector
n : The number of switches
Horizontal
31 n+3.5 ( n-1)
20
C4L Type
Ø4. Ø5/32[inch]
One-touch fitting
Ø4. Ø5/32[inch]
One-touch fitting
elbow type
11.2
0
31 -0.4
Refer to the above
pipe fitting part
10.4
C6L Type
14.4
0
31 -0.4
22.4
Ø6
One-touch fitting
elbow type
11.2
Ø6
One-touch fitting
12.8
14.4
22.8
N7L Type
Ø1/4[inch]
One-touch fitting
elbow type
11.2
Ø1/4[inch]
One-touch fitting
• The Digital pressure switch with panel mount adapter
can be removed from panel by releasing the hooks at
the switch sides
as illustrated.
more than 24
Pressure switch
and Panel mount
adapter may be
damaged if not
released correctly.
• Make connection after turning the power off.
• Install the lead wire separately from the route for power cable or
high-voltage cable. Otherwise, malfunction may potentially result
due to noise.
• Be sure to ground Terminal FG when using a switching regulator
obtained on the commercial market. If the analog output is
connected to a switching regulator obtained on the market, switching
noise will be superimposed and product specification can no longer
be met. This can be prevented by inserting a noise filter, such as a
line noise filter and a ferrite element, between the switching regulator
and the pressure switch, or by using a seriespower supply instead of
a switching regulator.
Connector Connecting/Disconnecting
• When connecting the connector, insert it straight onto the pins and
lock the connector into the square groove in the housing unit
connector clicks.
• When disconnecting the connector, press the connector lever to
disengage the lever claw from the square groove. Then pull the
connector straight out.
Housing
Square Groove
Pin
Lever
DC Polarity Mark
Lead Wire (Brown)
Hook
20.5
N7H Type
Notice when removing the switch
Vertical
20
C6H Type
Connection
Panel Mount Adapter plus Front Protection Cover
(Article No.ZS-27-D)
31 n+3.5 ( n-1)
C4H Type
T1 Type
NPT/8
14.4
Panel
Front Protection Cover
(ZS-27-01)
M5 0.8
18
R1/8
Protection Cover
more than 24
Refer to the above
pipe fitting part
• Mounting with Panel Mount Adapter and Front
Pipe Port
Refer to the following diagrams for pipe fitting part.
01 Type
Installation(continue)
Connector
Lead Wire (Blue)
13.2
Installation
7.2 17.8 8 9.5
34.5
Brown DC (+)
Panel Cut Dimensions for
Panel Mounting
Bracket
(Article No. ZS-27-B)
0
31 -0.4
M3x5L
8.75
Panel Thickness
0.5 to 6mm
• Mounting with Panel Mount Adapter
11
17.8 8
Tube
-25
NPN Open Collector Output
Max. 30V, 80mA
Residual Voltage not exceeding
1V
9.5
Load
12
to
- 24VDC
+
Black OUT
Blue DC (-)
One-touch Fitting
Brown DC (+)
-26
Analog Output Type
1 to 5V (±2.5% F.S.)
Load Impedance : Approx. 1k
Black OUT
(Analog Output)
+
-
Load
12
to
24VDC
Blue DC (-)
-28
Analog Output Type
4 to 20mA (±2.5% F.S.)
Maximum Load Impedance :
300 at 12V power supply voltage
600 at 24V power supply voltage
Minimum Load Impedance : 50
Panel mount adapter and Front protection cover
42.4
34.5
When the Lead wire with connector provided by SMC
CORPORATION is used, the colors of wire (Brown, Black, Blue) will
apply as shown on circuit diagram.
Main Circuit
22
Output Specification
Brown DC (+)
Black OUT
(Analog Output)
+
-
Load
12
to
24VDC
Blue DC (-)
Brown DC (+)
Panel Thickness: 0.5 to 6 mm
Panel Mount Adapter
(Article No. ZS-27-C)
Panel mount
adapter can be
rotated 90 degrees
to be attached.
-65
PNP Open Collector
Max. 80mA
Main Circuit
Panel mount adapter
1.Cut the tube perpendicularly.
2.Hold the tube, slowly push it into the one-touch fitting until it
comes to a stop.
Mount the bracket on the main unit using the two mounting screws
M3 5L and install on
the facility using
hexagon socket head
M3x5L
cap screws.
3
35
Caution :Tighten the pipe port to a torque of 7 to 9N·m.
Fasten the bracket mounting screws to a torque of 0.5
to 0.7N·m.
Pipe Connection (One-touch Fitting Type)
Internal Circuit and Wiring
Main Circuit
40
42.5
10
15
4.2
30
45
1.8
• Mounting with Bracket
View from Top
30
20
20
Bracket
Main Circuit
Mounting hardware
12
to
- 24VDC
+
Black OUT
Load
Blue DC (-)
Setting
Pressure Setting
ZISE##-TFI48GB-A
Setting Procedures
If set to Manual Setting
3.Output Mode Setting
Measurement Mode
The desired output mode can be set for switch output.
The output mode currently selected will be displayed.
Press the
or
button to switch to normal output “no” or
reverse output “nC”.
Initialize
no
(Normally open)
Set output mode, response time and display color change.
Pressure Setting
Press the
nC
(Normally closed)
button to set and move to response time setting.
4.Response Time Setting
Detects pressure, displays values and performs switching.
Other functions such as zero clear can also be set if necessary.
Initialize
Press and hold the
button for more than two
seconds. The display shown at the lower right will
allow the setting of the display color.
When the units specification of model indication is M, the SI units will be fixed. If no symbol is supplied,
see “Selecting Indication Unit”.
20
160
flashing
Press the SET button while in Measurement mode to display set
values. “P_1” or “n_1” and the current set value will display
alternately. Press the
button to move to the next set value, or
Press the
or
button to enter into the Value Change mode.
(See “Value Setting” )
640
1280
If the operating mode is set to Hysteresis, press
button to set
and move on to setting Auto Preset mode.
If the operating mode is set to Window comparator, press
button to set and return to Measurement mode.
If the Hysteresis mode is set, “H” and the set value of Hysteresis will be
displayed alternately (after the setting for “P1” or “n1”).
Press the
button to return to Measurement mode, or
Press the
or
button to enter into the Value Change mode.
(See “Value Setting” )
If set to Normally Open Mode
Switch Output
ON
Set value of Hysteresis (H)
OFF
If set to Normally Closed Mode
Switch Output
ON
Set value of Hysteresis (H)
OFF
P1
High pressure
n1
High pressure
1.Display Color Setting
Select a color for the LCD display.
When changing the display color, press the
or
button to select a display color.
Sor (Red/ON)
SoG (Green/ON)
rEd (Red)
Grn (Green)
Press the
button to set the desired display color and to move on to setting a
desired operation mode.
If the mode is set to analog output, press the
or
button,
to select a desired display color from
“Grn” (Green)
“rEd” (Red), then press the
button to set.
The display will move to operation mode setting.
2.Operation Mode Setting
The desired switch operation mode can be selected.
The operation mode currently selected will be displayed. Select
the desired operation mode by pressing the
or
button.
Hysteresis Mode
wnd
(Window Comparator)
Window Comparator Mode
ON
ON
ON
ON
OFF
OFF
OFF
OFF
P1
(Whe the product
is shipped)
Press the
n1
(Reverse)
P1
P2
(Whe the product
is shipped)
flashing
Press the
or
button to enter into the Value Change mode.
(See “Value Setting” )
Next, “H” and the set value of Hysteresis will be displayed
alternately. Press the
button to return to the normal
Measurement mode, or Press the
or
button to enter into the
Value Change mode. (See “Value Setting” )
If the initialize setting is Normally Open mode, “P_1” will be
displayed. “n_1” will be displayed if it is Normally Closed mode.
The set pressure value can be checked without holding or stopping
switch output operation.
If set to Normally Open Mode
Switch Output
ON
When the Hysteresis is set at less than or equal to 2 digits, the
switch output may chatter if input pressure fluctuates near the
set point.
HyS
(Hysteresis)
If the Window comparator mode is set, “P2” or “n2” and the current
set value will be displayed alternately (after the setting for “P1” or
“n1”). Press the
button to move to the next set value.
(Hysteresis : H)
flashing
The response time for switch output can be set.
Setting of the response time prevents chattering of
the output.
The response time currently set will be displayed. Select the
desired response time by pressing the
or
button.
2.5
flicker
Hysteresis mode setting
Input a set value for pressure to perform switch output.
Measurement Mode
Window comparator mode setting
n1
n2
5.Auto Preset Setting
This function is used to memorise a measurement
pressure as a reference value when Auto Preset input is set.
The settings currently set will be displayed. Press the
or
button to set to Auto Preset mode.
mAn
(Manual Setting)
Press the
button to set and return to Measurement mode.
Selecting Indication Unit
If the unit specification of the model indication
is without “-M”
The indication unit can be selected freely.
Pressing the
or
button will change the unit and will
automatically convert set values.
The units will change in the following order :
PA
GF
bAr
PSi
inH
mmH
Pa
(Reverse)
button to set and move to output mode setting.
AUt
(Auto Preset)
MPa
For Vacuum and Low Pressure
kgf/cm2
bar
psi
inchHg
For Positive Pressure
kgf/cm2
bar
mmHg
psi
Press the
button to set and to move on to setting the
display color.
Pressure Setting (continue)
Fine Adjustment Mode
(Fine Adjustment Function of Display Value)
Press the
button and
buttons
simultaneously for longer than two seconds while in
Measurement mode. “FSt” and the current pressure
Measurement value will be displayed. Press the
or
button to change the set value. If no operation is made for
longer than two seconds or the
button is pressed, the
display will return to the current pressure Measurement value
which will then display alternately with “FSt”.
Press the
button to display the adjusted amount
(percentage), which will then display flicker alternately with
“FSC”.
Press the
button to set and return to the Measurement
mode.
If set to Normally Closed Mode
Set value of Hysteresis (H)
Switch Output
ON
OFF
Set value of Hysteresis (H)
OFF
P1
P2
High pressure
n1
n2
High pressure
Auto Preset Mode setting
Press the
button while in Measurement mode to
select the Auto Preset mode. “AP1” will be displayed. Prepare a
switch unit for which pressure is to be set. Press the
and
buttons simultaneously while “AP1” is displayed to return to the
Measurement mode.
To execute Auto Preset, press the
button and “A1L” will be
displayed. Perform adsorption and desorption operations.
Detection will be made and a set value will be stored in the memory
automatically. Press the
button while “A1L” is displayed to
finish setting and to return to the normal Measurement mode.
Value Setting
To input a value for pressure setting or other
purposes:
1. Press the
or
button to enter the Set Value
Change mode. The first digit will flash.
2. Press the
or
button to set the desired
value.
(No operation within ten seconds after the Set
Value Change mode was selected results in
automatic setting of the value appearing in the
display window and in charging of the mode to Set
Value Change mode to Set Value Indication mode.)
3. Press the
button to make the next digit flash.
(If the highest digit is zero, “ ” or “ ” will flash.
“ ” means “+zero”, “ ” means “-zero”.)
(When the
button is pressed at the third digit, the first
digit will flash).
4. Press the
button continuously for longer than
one second to return to displaying set values.
Other Functions
ZISE##-TFI48GB-A
Peak and Bottom Hold Display Function
Maximum and minimum values are always detected and updated
during measurement. Displayed values can be held. For peak hold,
Press and hold the
button for longer than one second to hold the
maximum pressure value. The display will flash.
To reset holding, press and hold the
button for more than one
second. The display will return to measurement mode. For buttom
hold, press and hold the
button for longer than one second to
hold the minimum pressure value. To display will flash
To reset holding, pressure and hold the
button for more than
one second. The display will return to measurement mode.
Key Lock Function
This function prevents malfunction such as a set value being
changed by mistake. Press and hold the
button for longer than
four seconds to display which of “Loc” or “UnL” is currently set.
Select by pressing the
or
button and set by presing the
button. If button operation is
not desired, set to “Loc” to set the Lock mode. To release key lock,
Press and hold the
button for longer than four seconds to
display the current setting and set to “UnL”.
Zero Clear Function
The displayed value can be adjusted to zero when pressure to be
measured is within ±70digits of the atmospheric pressure.
(The range of ±10% F.S.setting is different depending on the
individual product difference)
This function is useful because it enables the detection of pressure
fluctuations larger than a certain value without being influenced by
fluctuations of source pressure. Press continuously the
and
buttons simultaneously to reset to “0” on the display. and
return to the Measurement mode automatically.
Error Display Function
This function displays error location and nature when a problem or
an error occurs.
Error Name Error Display
Overcurrent
Error
Residual
Pressure
Error
Pressurizing
Error
Error Nature
Troubleshooting
Method
A load current is flowig to
the switch output of 80mA
or more.
Turn the power off and
remove the cause of the
output oovercurrent.
Then turn the power on.
Pressure more than ±0.071MPa
for 1MPa or more than ±7.1kPa
for vacuum compared with the
atmospheric pressure is applied
during zero clear operation.
In three seconds, the mode will
reset to the Measurement mode.
±10% F.S. of the setting range
changes with individual product
differences.
Perform zero-clear
operation again after
restoring the applied
pressure to an
atmospheric pressure
condition.
Pressure outside of the high
limit of the set pressure
range is applied.
Pressure outside of the low
limit of the set pressure
range is applied.
Reset applied
pressure to a level
within the set
pressure range.
Displayed in the case of an
internal data error.
System
Error
Displayed in the case of an
internal data error.
Displayed in the case of an
internal data error.
Displayed in the case of an
internal data error.
Turn the power off
and turn it on again.
If resetting fails, an
investigation by SMC
Corporation will be
required.
Contact
AUSTRIA
BELGIUM
CZECH REP.
DENMARK
FINLAND
FRANCE
GERMANY
GREECE
HUNGARY
IRELAND
ITALY
(43) 2262 62280
(32) 3 355 1464
(420) 541 424 611
(45) 7025 2900
(358) 207 513513
(33) 1 6476 1000
(49) 6103 4020
(30) 210 271 7265
(36) 23 511 390
(353) 1 403 9000
(39) 02 92711
NETHERLANDS
NORWAY
POLAND
PORTUGAL
SLOVAKIA
SLOVENIA
SPAIN
SWEDEN
SWITZERLAND
UNITED KINGDOM
(31) 20 531 8888
(47) 67 12 90 20
(48) 22 211 9600
(351) 21 471 1880
(421) 2 444 56725
(386) 73 885 412
(34) 945 184 100
(46) 8 603 1200
(41) 52 396 3131
(44) 1908 563888
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
The descriptions of products in this document may be used by other companies.
© SMC Corporation All Rights Reserved.