Artesian2 Owners Manual
Energy-Efficient, Self Priming Centrifugal Pumps
Discharge
Inlet
Important Safety Instructions
Please read all instructions completely before you install or operate your new pump.
Save this manual for future reference.
General Specifications
Housing - Corrosion resistant polypropylene with 2” slip fittings.
Seal - Stationary type - Stainless Steel, with Buna trim, for 5/8” shaft.
Motors - NEMA 56Y Frame
WARNINGS
1. This pump and motor unit should be installed by a qualified electrician or serviceman in accordance
with all applicable state and local codes and ordinances, and in accordance with the National
Electrical Code. Improper installation may create a mechanical or electrical hazard which could
cause damage to property and which could result in serious injury or death. Always follow the
schematic on the motor for all electrical connections!
2. In order to avoid serious injury or death, always disconnect power to the motor before servicing
the pump.
3. Always use the schematic on the motor for all electrical connections.
4. Never run the pump dry. You must fill the priming pot with water and secure the lid before starting
the motor.
5. Never start the pump when the motor shaft is turning. To prevent unwanted motor rotation, install
a swing type check valve.
6. If you are not competent to install the pump, get help from a qualified source.
7. Maintain a minimum flow rate of at least two gallons per minute.
8. Visually inspect the pump and motor at least once a month. If there is
any leakage from the shaft seal, replace it at once. The seal faces
wear (just like car tires) and must be replaced periodically. For critical
applications, replace the shaft seal yearly.
5976 SE Alexander Street, Suite F
9. For 3 phase motors insure proper motor rotation.
Hillsboro, OR 97123
See item 7 in electrical for details.
P: 503-356-5888 F:503-356-1660
www.performancepropumps.com
General
Installation
Proper installation of your Artesian2 pump will help insure years of trouble free service.
1. Position the pump as near to the water and as low as is practical. This will help reduce priming time, avoid
cavitation, and maximize your pumps performance.
2. Minimize friction losses by using large diameter pipe, reducing the length of runs, and minimizing the
number of elbows and fittings as much as possible.
3. Protect the motor from excessive heat. It is best to provide shade from direct sun, and insure that it has
proper ventilation. Excessive heat will shorten the life of the motor and void the warranty.
4. Protect the motor against dirt, water and all foreign matter. If the motor has been flooded, do not operate
it until it has been checked by an authorized motor technician and has been found to be safe to operate. If
the motor is damaged by dirt, moisture, or corrosion it voids the warranty.
5. Mount the motor to a stable base where it will not get submerged.
6. The pump ports are 2” slip fit on both the inlet and discharge ports. The fittings used to connect to the
housing should be plastic. All plumbing lines should be self supported and properly aligned. This will
prevent undue stress to the housing. We recommend using a good primer and PVC cement to glue your
pipe to the tailpieces.
7. Installations in which the discharge pipe is elevated above the pump must use a swing type check valve to
prevent back flow and possible reverse rotation.
8. BEFORE STARTING THE PUMP, YOU MUST FILL THE PRIMING POT WITH WATER.
Electrical
1. If you are not competent to wire an electric motor, hire someone who is!
2. Make sure the power is disconnected before wiring the motor.
3. Make sure that the motor is wired internally so that it matches the supply voltage. If they do not match it
will damage your motor and void the warranty (i.e., If you are connecting it to a 115V breaker, make sure
the motor connections match the 115V (low) wiring diagram found on your particular motor.) Always follow
the schematic on the motor for all electrical connections.
NOTE: Baldor motors have sepeate wiring schematics for low (115V) and high (230V) applications. Both
schematics are shown for dual voltage motors.
AO Smith motors use a switch to change between low (115V) and high (230V) on dual voltage
motors. This switch is located under the rear cover on the back of the motor. The wiring
schematic is the same for these motos since the switch determines the voltage selected.
4. Use a supply wire of adequate gauge to prevent electrical line losses. The use of properly sized wire will
allow the motor to run cooler and more efficiently, by eliminating excessive line voltage loss.
5. Make sure all connections are clean and tight. Properly ground the motor. (There is normally a green
ground terminal located inside the motor connection box.) Make sure the ground wire is properly
connected to an electrical service ground.
6. Connect the pump permanently to an adequately sized circuit. It is best to have a dedicated circuit that
will not suffer a voltage drop from other loads.
7. When using 3 phase power the motor leads must be energized in the correct sequence to provide the
correct motor rotation. When viewed from the shaft end, the motor must rotate counterclockwise.
Incorrect rotation will destroy the pump and void the warranty.
If you are unsure of the sequence of your incoming electrical supply lines, remove the volute (front
housing) and diffuser from the pump, then connect the power and check rotation. If rotation is
incorrect, exchange any two of the connected leads and retest. When the rotation is correct, reinstall the
diffuser and volute (front housing).
* Never test rotation by bumping a connected electrical switch. This will destroy the pump
and void the warranty!!!!
2.
Pump Disassembly
All moving parts are located in the
rear sub-assembly of this pump.
Tools required:
Union Assembly
1. 3/32 inch Allen wrench.
2. 7/16 inch open end wrench.
3. 9/16 inch open end wrench.
4. Small and large flat bladed
screwdrivers.
5. Large Phillips screw driver.
Union
Assembly
O-ring
Allen
Screws
Seal
Lid O-ring
Motor
Impeller
Diffuser
Strainer Basket
Drain Plug
with Gasket
Volute
Motor Base
Diffuser O-ring
Disassembly and repair of the motor sub-assembly can be made as follows:
1. At the main panel turn off the circuit breaker for the pump.
2. Close all necessary valves on inlet and discharge lines and drain the pump by removing both drain
plugs.
3. Loosen and remove the six 3/8” P-bolts that hold the volute and the bracket together.
4. Pull the rear sub-assembly away from the volute. (The volute can remain attached to the plumbing.)
5. Loosen and remove the two 3/32” Allen screws that hold the diffuser to the bracket and remove the
diffuser.
6. Remove the set screw (if it has one) from the impeller eye. To do this, hold the impeller stationary, and
turn the set screw clockwise (it has a left-handed thread).
7. Hold the motor shaft stationary (by removing the cap on the opposite end of the motor and inserting a
screw driver in the slot, or a wrench on the flats, depending on the motor design) and unscrew the
impeller by turning it counter clockwise.
8. Loosen and remove the four 3/8” M-bolts that hold the bracket to the motor face.
9. If you wish to remove the shaft seal, place the bracket face down on a flat surface and press out the
carbon/spring seal from the back side. Never pry it out from the front.
10. Carefully remove the ceramic from the back impeller hub with a small straight screw driver.
11. Clean the bracket, seal bore housing, and the motor shaft as necessary.
Pump Assembly
Union Assembly
1. To install a new shaft seal, clean or replace the o-ring in
Nut the bore and apply a
the bore. If there is no o-ring, clean
Clamp
bead of 100% silicon sealant inside the bore and around
the top edge.
Tailpiece
Allen
2. Press the seal into the bore (without touching or putting
Screws
S-nut
O-ring
pressure on the delicate carbon
face) by pushing on the
Assembly
stainless steel collar. (A large socket or a pipe nipple
can be used). Make sure it is uniformly seated all the
way around.
3. Clean as necessary the impeller hub, and press in
the ceramic. Make sure that it is sitting flat. (The white
ceramic face must be showing - Not the rubber boot!)
4. Remount the bracket to the motor. Tighten the four
M-Bolts (3/8” cap screws).
Basket
P-Bolt
Bracket O-ring
Tailpiece
Lid
Bracket
Nut
Quick Clamp
Drain Plug
with Gasket
Volute
3.
Diffuser O-ring
Bracket
P-Bolt
Bracket O-ring
Seal
Motor
Motor Base
Pump Assembly Continued
5. Screw the impeller clockwise onto the motor shaft (while holding the motor shaft stationary) until it makes
firm contact. Screw in the impeller set screw (if it has one), with its gasket in place, (counter-clockwise to
tighten).
6. Mount the diffuser onto the bracket. Make sure the plastic pins fit into the holes in the bracket, then tighten
both Allen head screws.
7. Make sure the diffuser O-ring and bracket gasket are clean and properly seated.
8. Assemble the motor sub-assembly to the volute by using the two P-Bolts (3/8” cap screws) through bolts
with nuts for proper alignment. Do not tighten the through bolts until all six P-bolts are in place and finger
tightened. Tighten all six bolts uniformly and in a cross pattern.
9. Insert both drain plugs with gaskets and tighten. Install strainer basket and fill the pump with water.
10. Reinstall the lid and quick clamp, and turn it clockwise until snug.
Caution
1. The polished and lapped faces of the seal could be damaged if not handled with care.
2. DO NOT RUN THE PUMP DRY. It must be filled with water before it is turned on.
4.
PerformancePro Pumps
Artesian2 Series
Limited Warranty
This Artesian2 series product is warranted to the Purchaser (defined herein as the original end user) to be free of defects in construction and
workmanship at the time of purchase. In the event this product malfunctions within three years (for fresh water use) or one year (for use with salt water
or other suitable fluids) from the date of purchase the sole obligation of PerformancePro Pumps will be to replace or make this product capable of being
operated according to the original product description without charges for labor or parts to the Purchaser, and are subject to the following conditions:
1. The malfunction is proved attributable to a defect in construction or workmanship, including repairs performed under this warranty. Malfunction for
any other reason - including but not limited to misuse, abuse, negligence, accident, corrosion or salt build up, incorrect wiring or electrical supply,
tampering with parts, or improper installation - will not be remedied under this warranty. Problems or damage from failure to comply with instructions in
the owner’s manual, improper plumbing and positioning, flooding, incompatibility with fluid chemistry and running unit dry are not covered under this
warranty.
2. PerformancePro Pumps must perform all warranty repairs. Purchaser must retain the purchase receipt and present it with this certificate as proof of
ownership and entitlement to warranty repairs. The cost of unauthorized repairs will not be reimbursed to Purchaser by PerformancePro Pumps, and
are not the responsibility of PerformancePro Pumps. If repairs by Purchaser or a third party damage the product, such damage is not remediable under
this warranty.
3. Purchaser shall bear all shipping, packing, and insurance costs and all other costs, excluding labor and parts necessary to effectuate repairs under
this warranty. Purchaser will pay for return freight.
4. For applications that involve fluids other than water, the Purchaser shall retain and present to PerformancePro Pumps evidence of purchaser’s
compatibility tests under actual operating conditions. Any problems caused by a chemical incompatibility of the fluid with the pump materials, are
expressly not covered by this warranty.
5. Periodic check-ups and/or maintenance are not covered by this warranty.
6. For all sales in the State of Oregon this is the sole and exclusive manufacturer’s warranty. There are no warranties which
extend beyond the warranty set forth herein, and in accord with Oregon Revised Statutes ORS 72.3160 any and all implied
warranties, including any warranties of merchantability and fitness for particular purpose, are disclaimed and excluded. Some
States do not allow disclaimers/exclusions of, or limitations on how long an implied warranty lasts, so in such States, and
except as is otherwise provided by applicable law of said States, no action on a warranty implied at law shall be commenced
more than one year following the date of purchase. No action shall be brought for breach of any express warranty subsequent
to the expiration of the express written warranty.
7. Incidental and consequential damages (specifically including, but not limited to, damages for loss of profits or damages
relating to down time of personnel, equipment, or facilities) caused by malfunction, defect, or otherwise, whether alleged to
be the result of breach of any express or implied warranty, or the negligence, willful misconduct or other act of
PerformancePro Pumps are not the responsibility of PerformancePro Pumps, and to the extent permitted by law, are hereby
excluded, including, but not limited to property damage, and to the extent not prohibited by applicable law, personal injury or
death and Purchaser hereby agrees to expressly waive any claim for all such damages. If a final determination is made in a
court of competent jurisdiction that any one or more of the damages which are disclaimed, excluded and/or waived under this
paragraph are not allowed under public policy or applicable law, then the disclaimer, exclusion and waiver of all of the other
damages not prohibited by public policy or applicable law shall continue to apply.
8. This warranty does not apply to any malfunction arising out of any application of this product other than in a use compatible with the manufacturer’s
product description, unless such application is, upon request, specifically approved in writing by PerformancePro Pumps.
9. The provisions of this warranty are severable and if any provision shall be deemed invalid, the remaining provisions shall remain in full force and
effect.
10. This limited warranty extends only to the original Purchaser (end user) and does not extend to transferee or purchaser from the original Purchaser.
Any purported assignment without the consent of PerformancePro Pumps shall be null and void.
11. No warranty whatsoever of chemical compatibility or application suitability is given. It is the sole responsibility of the Purchaser to determine if the
merchandise purchased is suitable for Purchaser’s specific application. PerformancePro Pumps strongly advises that the customer perform any and all
tests necessary to determine material compatibility and product suitability for customer’s specific conditions and needs.
12. This contract shall be governed by and in accordance with the laws of the State of Oregon. Purchaser agrees that proper jurisdiction and venue for
any claim brought hereunder is in Washington County, Oregon.
13. This limited warranty is incorporated by reference into the contract of purchase for the products supplied by PerformancePro Pumps to Purchaser
under said contract.
ARTESIAN2 PUMP PLACEMENT CHART
When determining the placement of your Artesian2 pump, two factors will be influenced by its height
above water level. First, is its ability to self-prime. To insure a reasonable prime time without the use
of a swing type check valve (do not use spring loaded check valves), position the pump no higher than
the height shown in the “maximum recommended suction lift” column. Second, is its ability to maintain
a prime and minimize cavitation. Even with a swing type check valve, we do not recommend a pump be
installed more than 9 feet above the water level.
MODEL
MAXIMUM RECOMMENDED
SUCTION LIFT
APPROXIMATE TIME
TO PRIME
A2-1/8-39
2 FEET
15 MINUTES
A2-1/4-47
3 FEET
15 MINUTES
A2-1/4-58
3 FEET
15 MINUTES
A2-1/3-63
4 FEET
15 MINUTES
A2-1/2-76
5 FEET
15 MINUTES
A2-1/2-HH
3 FEET
10 MINUTES
A2-3/4-HF/HH
4 FEET
10 MINUTES
A2-1-HF/HH
5 FEET
10 MINUTES
A2-1 1/2-HF/HH
6 FEET
10 MINUTES
A2-2-HF/HH
7 FEET
10 MINUTES
A2-3-HF/HH
8 FEET
10 MINUTES
Notes:
1. The data in this chart was compiled using 2” pipe, 10’ in length. If you use larger pipe or have longer
runs, it will increase the time required to prime.
2. All PerformancePro self-priming pumps have been tested to operate up to a height of 9’ above the
surface of the water. Do not install your pump higher than 9’.
3. If you use small pipe, more fittings, have longer runs, use strainers, or in any other way make it harder
for water to flow easily to the pump - it will reduce your maximum recommended height and may increase
the time to prime.
PerformancePro Pumps Inc.
5976 S.E. Alexander St., Suite F, Hillsboro, OR 97123
Phone:503/356-5888 Fax: 503/356-1660
www.performancepropumps.com
WIRING INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Please read all instructions completely before you
install or operate your new pump.
Save these instructions for future reference.
The motors used with the PerformancePro pumps are high quality, industrial duty motors. Some are dual
voltage motors, which can be operated at either 115 volt (low) or 230 volt (high). They have been tested at
the factory before being shipped.
It is vitally important to supply proper voltage and amperage to the motor. Set the internal connections on
your motor to match your supply line voltage. If these do not match, you will damage the motor and void the
warranty. DO NOT ATTEMPT TO WIRE THE MOTOR IF YOU DON’T KNOW WHAT YOU ARE DOING!!!
Have a qualified electrician do the work.
The following example shows how to wire a typical Baldor 1/4HP, Single Phase, 1725 RPM motor
(with the following diagram)
LOW VOLTAGE (115V)
HIGH VOLTAGE (230V)
LINE A
LINE B
TOGETHER
1, 3
4
2, J
LINE A
LINE B
TOGETHER
1
4
2, 3
TAPE
J
CONNECTIONS ABOVE GIVE CLOCKWISE ROTATION FACING LEAD END.
For low voltage:
1. Connect your incoming hot lead (normally the black wire) to the wires marked #1 and #3.
2. Connect your incoming neutral lead (normally the white wire) to the #4 wire.
3. Twist wires #2 and #J together.
4. Use appropriately sized wire nuts to insure all connections are secure and insulated.
5. Connect your incoming ground (normally green) to the green screw in the connection box.
For high voltage:
1. Connect your incoming hot lead (normally the black wire) to wire #1.
2. Connect your other hot lead (normally the white wire) to wire #4.
3. Connect wire #2 and #3 together.
4. Tape off the wire marked J.
5. Use appropriately sized wire nuts to insure all connections are secure and insulated.
6. Connect your ground lead (normally green) to the green screw in the connection box.
Note: Your motor may have a different wiring diagram.
Follow it’s instructions for line placement.
PerformancePro Pumps Inc.
5976 S.E. Alexander St., Suite F, Hillsboro, OR 97123
Phone:503-356-5888 Fax: 503-356-1660
www.performancepropumps.com