D1000GT
Brew Count Total
Brew Count Total
Press  to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to 15º)
Press  to select, < > to select desired setting (CBL 5, 15 or OFF), to set.
Cold Brew Lock
Master Reset
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is
within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew mes‑
sage, however it will brew at any temperature.
Master Reset
Press  to display Are You Sure?
Then < for Yes, > for No.
Brewer factory defaults are then reset.
Service Call
Service Call (Phone number Factory set to [800] 995-0417)
Press  to display number and change number or < to move place and EX to exit when complete This number will be displayed dur‑
ing a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
Access Code (Factory set to 1‑2‑3‑4)
Press  to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete.
Banner Name
Banner Name (Factory set to Curtis)
Press  to display letters and change letters or < to move place and EX to exit when complete. This feature allows up to 14 letters to
be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner Name is
displayed every 5 sec. on and off.
P-Maintenance
P-Maintenance (Factory set to OFF)
Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press  to exit.
Beeper On/Off
Pulse Brew
On/Off
Beeper On/Off (Factory set to ON)
Press  to display ON or OFF. Pressing either < > toggles between on and off. to set.
Pulse Brew (Factory set to OFF)
Press  to select. Display will now show Select Button. Select desired Brew button to program. The next screen will promt you to
press < > to select OFF or one of four pulse patterns (A to E) .
Guidelines for Pulse Brew:
This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind
profile and water conditions, the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically
extract better with the A and B pulse setting. Decaffienated coffees typically extract better with the B pulse setting. High-Yield coffees
typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste profile. There are
two additional settings (D and E) that alow you to manually set the ON TIME pulses and OFF TIME.
Display Brew
Time
Drip-Out
Mode
Exit
If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point. Cold Brew Lock and Pre-infusion disappears
from the list of program selections. When Pulse Brew is ON, Pre-Infusion disappears from the list of program selections.
Display Brew Time (Factory set to ON)
Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set. When on, the Display Brew Time feature
allows you to see the remaining time in the brewcyle counting down.
Drip-Out Mode (Factory set to 2 min) Press  to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease
the time and turn OFF. Time counts up in 5 second increments. Press  to set.
Exit
Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
Brew Volume – Easy Access
To access the brew volume without entering the program mode.
The UCM must be on. To adjust the D1000GT brewer, press and hold down the center, Select button 2 . The screen will read
Vol. Adj. < -0
> Oz.
pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.
- Select +
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water
Temperature will be displayed (temperature in heating tank).
3
D500GT
Model Select
Exit
Model Select
Press  to select, < or >. Be sure that Airpot Brewer is selected. Screen choices are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer
and Thermo-Alpha. Press  to set. All menu settings will default to factory standards whenever a new model is selected.
Exit
Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
Brew Volume – Easy Access
Units produced beginning January 2008 can be easily adjusted from the front panel. Written into the software on the D500GT
UCM, is a feature to access the brew volume without entering the program mode.
The UCM must be on. To adjust the D500GT brewer, press and hold down the center, Select button 2 . The screen will read Vol. Adj. < -0
> Oz.
pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.
- Select +
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 6) for 5 seconds. Water
Temperature will be displayed (temperature in heating tank).
Parts List
D500GT
Item
Nº
1
1A
2
3
4
5
5A
6
7
7A
8
9
10
11
12
12A
13
8
Part Nº
WC-2977-101
WC-2962
WC-37064*
WC-39346
WC-37252
WC-3621-101
WC-3316
WC-5310
WC-5450
WC-58117**
WC- 889*
WC-29025*
WC- 102*
WC-6221
WC-3503
WC-3518
WC- 826L*
Description
FITTING ASSY, SPRAYHEAD
FITTING, SPRAYHEAD ASSY PLTD
KIT, LABEL & UCM D500GT CURTIS
LABEL, CNTRL PNL (CURTIS LOGO)
KIT, HOT WATER FAUCET RPLCMNT
BREWCONE, UNIV7 1/8” BLK PLASTIC
BREWCONE, ASSY S.S. (OPTIONAL)
TUBING, SILICONE, 5/16” I.D. ( 1 FT.)
COVER, TOP (OLDER MODELS)
COVER, TOP D500GT
VALVE, DUMP LEFT 120V
SPRAYHEAD, PURPLE ADVANCE FLOW
SWITCH, TOGGLE 125/250 VAC RESISTIVE
GRID, DRIP TRAY AIRPOT (OPTIONAL)
LEG, SCREW BUMPER 3/8-16 STD
LEG, GLIDE 3/8”-16 STUD SCREW
VALVE, INLET 1 GPM 120V 10W
Item
Nº
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
29A
Part Nº
WC-8591
WC-3763*
WC-3765L*
WC- 830
WC-5853-102
WC-6277
WC-37278*
WC- 917-04
WC-4394
WC- 523
WC-43062
WC-43058
WC-1438-101*
WC-5231*
WC-1806
WC-62049
WC-6217
Description
CAPACITOR, X2
KIT, VALVE REPAIR USE ON WC-889
KIT, VALVE REPAIR USE ON WC-826
WASHER, FLW ½” 1.0 GPM USE W/WC-826
COVER, TOP HEATING TANK GEN USE
TANK COMPLETE, D500GT 120V
KIT, LIQUID LEVEL PROBE GT
HEATING ELMNT 1450W 120V W/NUTS
GUARD, SHOCK HEATING ELEMENT
THERMOSTAT, MANUAL RESET
GASKET, HEATING TANK
PLUG, TANK DRAIN, PP RED
SENSOR, HEATING TANK
COMPOUND, SILICONE 5 OZ TUBE
SEAT CUP, SILICONE (USE ON WC-1809)
COVER, FRONT SS D500GT SHORT
COVER, FRONT (UNITS PRIOR TO 12/1/08)