Water Quality Testing Products

Water Quality Testing Products
Innovation for you. Innovation by you.
The Next Revolution in Water Analysis is Here!
1
2
3
Inject Water into the Disk Insert the Disk into the meter Click “Run Test”
Now test up to 10 factors in only 60 seconds. Simply inject 3mL of sample into a
Spin Disk and place it in the Spin Colorimeter. Each test well is filled, reacted, mixed
and analyzed automatically.
Designed by LaMotte for precise colorimetric analyses, this truly innovative Spin
technology eliminates several potential user errors. No more glassware to clean or
special mixing and timing instructions to follow. The Spin Disk contains dried reagents in each test well. A filled diskplaced in the Spin Meter is rotated at high speed
to deliver sample into every well. A unique, magnetic mixing process completes each
reaction andthe multi-wavelength colorimeter rapidly analyzes every well.
The result is exceptionally precise and repeatable data. Initially designed for pool
and spa professionals a new portable version will follow this bench-top model. Visit
the WaterLink Spin web page to see product videos and let us know if your testing
application needs a similar device.
See page 68 for more details or scan code.
TO ORDER - SEE BACK COVER
CAPABILITIES
Capabilities............................................................................................................. Page 4
CUSTOM KIT SERVICES & INTERNATIONAL SALES
Custom Kit Services & International Sales .............................................. Page 5
TEST METHODS
Colorimetric .......................................................................................................... Page 6
Electronic............................................................................................................................7
Titrimetric ..........................................................................................................................7
INSTRUMENTATION
SMART 3 Colorimeter..................................................................................Pages 8-9
2020w Portable Turbidity Meters................................................................... 10-11
LTC-3000w Turbidity & Chlorine Laboratory Meter................................ 12-13
SMART Spectro Spectrophotometer............................................................ 14-15
COD Reagents & Heater Blocks .............................................................................16
Instrument Reagent Listing ............................................................................ 17-18
1200 Single Test Colorimeter Labs .............................................................. 19-21
TRACERS: Total Chlorine, pH, ORP, Options, EC/TDS/Salt.................... 22-24
pH/Conductivity, DO
Dissolved Oxygen Meters..........................................................................................24
PockeTesters: pH, Double Junction ORP, Salt, Thermometer, .......... 25-27
Microprocessor-Based TDS and EC Dual Range
Temperature Measurement.....................................................................................28
LaMotte pH, TDS, Conductivity Meters ...............................................................29
pHPLUS Direct Digital pH/ISE Meter and Electrodes ...................................30
DPD Replacement Reagents...................................................................................31
pH Buffers/Electrode..................................................................................................32
Conductivity Solutions................................................................................................33
INSTA-TEST® TEST STRIPS
Insta-Test® Test Strips ......................................................................... Pages 34-35
MICROBIOLOGICAL TESTING
Microbiological Testing......................................................................... Pages 36-38
INDIVIDUAL TEST KITS
Acidity to Zinc Test Kit Listing ........................................................... Pages 39-55
COMBINATION OUTFITS
Aquaculture & Aquarium Water .................................................................Page 56
Environmental Studies ...................................................................................... 57-60
Food/Laundry......................................................................................................... 61-62
General Water Analysis....................................................................................... 63-64
Industrial Waters.................................................................................................. 65-68
Pool & Spa Waters .............................................................................................. 69-72
Water & Wastewater........................................................................................... 73-74
Water Conditioning......................................................................................................75
REAGENT REFILLS
Numerical Listing .................................................................................. Pages 76-83
APPARATUS
Beakers to Thermometers ...................................................................Page 84-90
CATALOGS & HANDBOOKS
Application Specific Catalogs & Handbooks..................................Page 91-92
STANDARDS
Complete List of Standards .............................................................. Pages 93-94
INDEX
Acidity to Zinc........................................................................................... Pages 95-98
Capabilities
LaMotte Company manufacturers its products
at its 65,000 square foot facility in Chestertown,
Maryland, near Washington DC on the east coast
of the United States.
Now, almost 10 years into its Lean Manufacturing journey, LaMotte’s chemists, engineers, and
technicians continue to optimize a wide variety
of processes to achieve maximum quality and
efficiency.
We offer a wide range of test methods and tools
for the analyst. From multi-factor test strips,
foil-packaged unit dose tablets, unit dose powder vials, and liquid reagents to sonic-welded
color comparators, multi-parameter test kits,
and electronic instruments. LaMotte controls
the manufacturing of all aspects to ensure the
highest quality.
We believe strongly in having a team of technical
experts available by phone and email for customer support. The Research and Development
team works to constantly improve and create
new test methods. Our in-house graphic design
department provides extensive services that are
especially valuable for the many custom designed
product projects that LaMotte welcomes.
All of these varied capabilities enable LaMotte
to excel at helping people solve their analytical
challenges.
4
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Custom Test Kit Services
If your needs go beyond our standard product line,
then our Custom Test Kit Services Department
can design a custom kit to meet your needs.
WE CAN design a kit that
combines any grouping
of parameters you need.
WE CAN develop new
test methods for new
proprietary compounds
or for control of
specialized treatment
programs
WE CAN alter existing
graphics and packaging
or design something
new for private labeling
purposes
How The Custom Test Kit Service Works
1.Contact our Customer Service or International Sales departments by phone,
fax, or email. Tell us how you plan to use the product, the level of accuracy
and range you need, how many kits, and any limitations such as size, weight,
cost, or skill level of the end user (i.e. student, consumer, technician).
2.We will prepare a quote for you. Based on the information you provide, we will
suggest one of our non-catalog test kits or develop a kit to suit your needs.
3.Once you order, we immediately begin the development process, subject to
final approval before beginning production.
International Sales
Worldwide Distributor Network
Available online at www.lamotte.com:
ƒƒEntire Product Listing with Full Descriptions
ƒƒPrintable Test Instructions
ƒƒPrintable MSDSs
ƒƒPrintable Reagents Certificates of Analysis
For Pricing and To Order, contact a distributor near you.
To locate a LaMotte distributor, visit www.lamotte.
com and select “global sales”. For more information
email us at intl@lamotte.com.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
5
Test Methods
Colorimetric
Colorimetric
There are two basic types of colorimetric tests:
1.Tests which determine the concentration of a substance are based on Beer’s Law. Simply stated, this says that the higher the concentration of a
substance, the darker the color developed in the test, so more light is absorbed by the sample.
2.pH tests use an indicator which changes color with changes in the concentration of hydrogen ions, or the acidity of the solution.
Octa-Slide 2
Comparator
6
LRC Comparator
The new Octa-Slide 2 replaces the Octet and original
Octa-Slide comparators. All 8
color standards can be viewed
at once against a precision
matched color bar top-loaded
next to the sample tube. This
comparator system can be
used with existing reagent
system but is not compatible
with color bars from the original Octa-Slide.
This innovative new design
replaces the Axial Reader
with a far more simplistic and
significantly improved optical
system. Simply place one reacted sample in the front and
one un-reacted sample behind it and let the light shine
down into both tubes. Precision matched glass ampoules
are in the slide bar so even the
most sensitive low range colors can be matched one-onone with extraordinary ease
and confidence.
Test Strips
Color Chart Comparator
Test strips are either dipped
or swirled in test solutions.
The resulting color reaction
is compared to a color chart
provided.
Color charts are laminated color
standards. The reacted sample
is held against the panel and
compared to the color standards.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Test Methods
Electronic • Titrimetric
Electronic Methods
Electronic colorimeters measure the amount of light which travels through the reacted sample, and convert the measurement
to a reading as ppm, absorbance or %T. In addition to colorimeters, LaMotte offers instruments to test pH, TDS/conductivity,
dissolved oxygen, and turbidity.
NEW! See page 68 for details
Titrimetric
Titrimetric tests can be used to determine the concentration of a substance in a sample solution. After the sample is treated with an indicator, a standard
titrant is added until a color change indicates a completed reaction. LaMotte offers four separate types of titration methods, allowing a choice of precision and convenience.
Automatic Buret
The self-zeroing automatic
buret is calibrated from 0 to
10 mL in 0.1 mL increments.
It is available with a squeeze
valve (pinchcock), glass stopcock, or Teflon® stopcock.
See page 85 for full line of automatic burets.
Direct Reading Titrator
The Direct Reading Titrator is a 1.0 mL
microburet calibrated to allow direct
reading of the test result. Each Titrator
has a specific range, but may be refilled
to test higher concentrations.
Dropper Pipet
The drop count test uses a pipet to
provide fast, reliable measurements in
the field. The number of drops used to
obtain a color change is multiplied by a
given factor to produce the test result.
Dropper Bottle
The dropper bottle test uses bottle tips which deliver a
consistent standard drop size to add titrant to the sample.
As with the drop count test, the number of drops used to
complete the reaction is multiplied by a given equivalence
factor to determine the concentration. Many dropper bottle
tests use different sample sizes for different equivalences.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
7
Instrumentation
SMART3 Colorimeter
Replaceable cup
protects optics
Backlit
Display
Simple
6-button keypad
Over 80 Pre-Programmed Tests
The user-friendly SMART3 Colorimeter is the ideal direct
reading colorimeter for complete on-site water analyses.
All pre-programmed tests can be run on these compact instruments and
each test features automatic wavelength selection. The entire multi-LED
optical system is embedded in the light chamber and optimized for LaMotte
test reagent systems. The analyst can simply select the test and put in the
sample with reagent. The microprocessor, which selects the wavelength,
also allows the user to load up to 25 tests for analyzing custom reagent
systems. LaMotte stands behind every system we provide.
These portable colorimeters have the user in mind with these advanced
features:
ƒƒ IP67 Waterproof
ƒƒ Simple, menu-driven operation
ƒƒ Alphabetical test selection
ƒƒ User-selected test sequences
ƒƒ Self diagnostics with error/warning messages
ƒƒ Instant readiness without “count down” delays; achieved by active
Code 1910
The user may select any of the wavelengths in each meter to
determine the absorbance or %T of a sample at the desired
wavelength.
Additional advancements include:
ƒƒ Superior narrow band-width interference filters
ƒƒ New Super Twist LCD display for improved readability
ƒƒ USB interface
ƒƒ Optional software for data storage and manipulation
ƒƒ Lithium ion rechargeable battery, USB computer adapter
is included
As well as the incorporated features:
ƒƒ All wavelength filters - 428, 525, 568, 635 nm (SMART3
only)
ƒƒ USB port
ƒƒ and more...
stabilization of lamp intensity
ƒƒ Auto-blank; Auto-off
ƒƒ European CE mark
8
* SMART 3 Turbidity is not the same as EPA Turbidity
SMART Colorimeter® is a registered trademark of LaMotte Company.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
SMART3 Colorimeter & SMARTLink 3
SMART3 • Code 1910
Range:
Resolution:
Accuracy:
0-125%T
1% FS
2% FS
CE Mark:
Light Source:
Yes
LED/Filter setup; 428nm, 525nm, 568nm, 638nm
Detector:
Display:
Sample Cell:
Datalogging:
Keypad:
Calibration:
Power:
Photodiode
160x100 Backlight LCD, 20x4 line graphics display
25 mm round cell, 10 mm square cuvette, 16 mm COD tubes
Up to 500 data points, USB transfer, time and date stamped
6-button mechanical
Factory set - user adjustable
USB computer/power charger or Lithium Ion rechargeable battery,
3.7V, 2.5” x 0.75”, 1.7 oz.
19.05 x 8.84 x 6.35 cm; 7.5 x 3.5 x 2.5 inches
15 ounces
10 mm typical
Dimensions:
Weight:
Bandwidth:
Comes with 6 sample tubes, power charger and manual
Accessories/Replacement Items:
Smartcheck Standards
Replacement Sample
Chamber Cup
COD/UDV adapter
6 sample tubes USB Cable USB Power Plug Car Charger Small Case
Large Case
Code 4148
Code 3-0038
Code 1724
Code 0290-6
Code 1720
Code 1721
Code 5-0132
Code 1910-GCS150
1910GCS-440
SMARTLink 3 Program
Order Code 1901-CD
Interface the SMART Spectro, SMART3, 2020w and LTC-3000w meters with a Windows-based personal computer.
The program can be used to download data stored in the dataloggers of these meters. The program allows the
user to identify, organize, view, manipulate and store data as a database on a PC. Data can also be copied and
pasted or exported to other applications as a CSV file.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
9
Instrumentation
2020w Portable Turbidity Meters
Industry-leading precision, sensitivity, and dependability in one of
the most innovative handheld meters available on the market!
NOW WATERPROOF!
The multi-detector optical configuration assures long term stability and minimizes stray
light and color interferences. All readings are determined by the process of signal averaging
over a 5 second period. This minimizes fluctuations in readings attributed to large particles
and results in rapid, highly repeatable measurements. Ideally suited for both low-level
drinking water applications as well as monitoring high turbidity in the field.
Waterproof to IP67
Lithium rechargeable batteries
USB port
7 languages
Backlit display
EPA and ISO versions
ƒƒ Patent pending optical design features focusing optics for
low range precision and accuracy
ƒƒ Seven user selected languages – English, Spanish, French,
Japanese, Chinese, Italian, and Portuguese
ƒƒ Advanced calibration algorithms
ƒƒ Easy menu driven operation and large LCD display
ƒƒ 500 point data log; stored results can be viewed directly on instrument or downloaded
to a computer via USB cable and SmartLink 3 software (available separately)
2020we version meets US EPA design criteria as specified by EPA 180.1,
Rev. 2.0 (1993) and Standard Methods 2130 B-2001.
2020wi version meets design criteria for quantitative methods of turbidity
using optical turbidimeters as specified by ISO 7027.
Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four
sample tubes, USB cable and wall adapter.
10
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
2020w Portable Turbidity Meter
To Order:
Included:
2020we Kit • Portable turbidity meter complies with by EPA 180.1, Rev. 2.0 (1993) and
Standard Methods 2130 B-2001; Order Code 1970-EPA
2020wi Kit • Portable turbidity meter complies with ISO 7027 Standard; Order Code 1970-ISO
ƒƒ 0 NTU Standard (ISO and
EPA), 60 mL; Code 1480
ƒƒ 1 NTU Standard (ISO),
60 mL; Code 1453
ƒƒ 10 NTU Standard (ISO),
60 mL; Code 1454
Options:
ƒƒ 100 NTU Standard (ISO),
60 mL; Code 1455
ƒƒ 1 NTU Standard (EPA),
60 mL; Code 1450
ƒƒ 10 NTU Standard (EPA),
60 mL; Code 1451
ƒƒ 100 NTU Standard (EPA),
60 mL; Code 1452
ƒƒ Formazin Standard
Solution, 4000 NTU, 60
mL; Code 6195-H
ƒƒ USB Cable, Code 1720
ƒƒ Wall Adapter, Code 1721
ƒƒ SMARTLink 3 Software;
Code 1901-CD
ƒƒ Six-pack of vials;
Code 0290-6
ƒƒ Car Charger;
Code 5-0132
Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four sample tubes, USB cable and wall adapter.
Turbidity Specifications:
Unit of Measure
2020we
Units of Measure
2020wi
Range*
Resolution*
Accuracy*
Detection
Limit
Range
Selection
Reproducibility*
Light Source
NTU, AU, ASBC, EBC
FNU, FAU, ASBC, EBC
0-4000 NTU/FNU, 0-10,500 ASBC, 0-150
EBC
0.01 NTU/FNU 0.00-10.99
0.1 NTU/FNU 11.0-109.9
1 NTU/FNU 110-4000
From 0-2.5 NTU the accuracy is ±0.05 NTU.
From 2.5-100 NTU the accuracy is ±2%.
Above 100 NTU the accuracy is ±3%.
0.05 NTU/FNU
Automatic
Meter Features:
Signal Averaging
Power
AC Power
Data Logging
Auto Shut-Off
Optional Software
Languages
Disabled, 2, 5, 10
USB computer cable, wall adapter or Lithium ion
rechargeable battery, 3.7V, 2.5” x .75”, 1.7 oz
Optional
500 points
Disabled, 5, 10, 30 seconds
SmartLink 3
Response Time
Size
English, French, Spanish, Japanese, Italian,
Portuguese, Chinese
<2 Seconds
7.5 x 3.5 x 2.5 inches; 19.05 x 8.84 x 6.35 cm
Weight
Display
13 ounces
6-line LCD with backlit display
0.02 NTU/FNU or 1%
Tungsten (EPA), complies with EPA 180.1,
Rev. 2.0 (1993) and Standard Methods 2130
B-2001; 860nm LED (ISO), complies with ISO
7027
*Over 600 NTU/FNU units expressed as AU/FAU
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
11
Instrumentation
LTC-3000w Turbidity, Chlorine & Color Laboratory Meter
Industry leading precision, sensitivity and dependability in one of the most innovative meters
available on the market for the measurement of Turbidity, Chlorine & Color.
Code 1972-EPA
Code 1972-ISO
Kits supplied with 0, 1 and 10 NTU standards, 6 sample
tubes, DPD tablets, USB cable and AC adapter.
The LTC-3000we uses a tungsten lamp and
meets the specifications of EPA 180.1.
The NEW LTC3000w is a benchtop turbidity, chlorine and color meter with wide range
and high accuracy. ISO unit also available. The meter meets EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001 for turbidity and Standards Methods 4500-Cl G
for chlorine. The turbidity range is 0-4,000 NTU with a MDL of 0.05 NTU. The free and
total chlorine range is 0-10 ppm with a MDL of 0.03 ppm. The meter can store 500 data
points which can be downloaded to a computer, allows 7 different languages, and runs
on rechargeable batteries or a USB computer/wall adapter.
ƒƒ Ideally suited for both low-level drinking water applications as well as monitoring
high turbidity
ƒƒ Special focusing optics
ƒƒ Supports 7 languages: English, French, Spanish, Chinese, Japanese, Portuguese
Meter Features
Signal Average
Disabled, 2, 5, 10
Power
USB computer cable, wall
adapter or Lithium ion
rechargeable battery, 3.7V,
2.5” x 0.75”, 1.7 oz
Data Logging
500 points
Auto Shut-Off
Disabled, 5, 10, 30
Languages
English, French, Spanish,
Japanese, Italian, Portuguese,
Chinese
Response Time
<2 Seconds
Dimensions
8.75 W x 7.75 D x 3 H inches
22.2 W x 19.7 D x 7.6 H cm
and Italian
ƒƒ Data logging up to 500 points with a date and time stamp – stored tests can be
viewed on the meter or downloaded to a PC
ƒƒ Compatibility with existing SmartLink 3 software
ƒƒ Easy to read graphic LCD display
ƒƒ Easy menu-driven operation
12
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
LTC-3000w, Turbidity, Chlorine & Color
Turbidity
ƒƒ Meets design criteria for quantitative methods of turbidity using
optical turbidimeters as specified by EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001
ƒƒ Two user selected factory calibration modes:
-- Formazin
-- Polystyrene Japanese Turbidity Unit (Japanese Water Works
Regulation)
ƒƒ Supplied with formazin verified styrene divinylbenzene bead
suspensions (AMCO) for easy and accurate field calibration
ƒƒ User selected signal averaging (disabled, 2, 5 or 10
measurements)
ƒƒ Blanking with turbidity-free water allows a zero point calibration
for increased accuracy at very low turbidity levels
Unit of Measure
Range*
Resolution*
Range Selection
Accuracy*
Detection Limit
Reproducibility*
Stray Light
Light Source
Signal Averaging
NTU, FNU, AU, FAU, ASBC, EBC
0-4000, 0-10,500 ASBC, 0-150 EBC
0.01 NTU/FNU 0.00-10.99; 0.1 NTU/FNU 11.0-109.9;
1 NTU/FNU 110-4000
Automatic
From 0-2.5 NTU/FNU the accuracy is ±0.05 NTU/FNU.
From 2.5-100 NTU/FNU the accuracy is ±2%. Above
100 NTU/FNU the accuracy is ±3%.
0.05 NTU/FNU
0.02 NTU/FNU, or 1%
<0.02 NTU FNU
Tungsten (EPA), complies with EPA 180.1, Rev. 2.0
(1993) and Standard Methods 2130 B-2001, 860mm
LED (ISO), complies with ISO 7027
Disabled, 2, 5, 10
*Over 600 NTU/FNU units expressed as AU/FAU
Chlorine
ƒƒ Exceeds design specifications for Standard Methods
4500-Cl G
ƒƒ Liquid and tablet DPD calibrations for Free and Total
Range
Resolution
Accuracy
Chlorine measurement
ƒƒ Wide-range accomplished with same cell and reagent
dosage
ƒƒ Low level detection.
ƒƒ User selected units ppm or mg/L
Detection Limit
Response Time
Light Source
Color
ƒƒ Uses Platinum-Cobalt method from Standard Methods 110.2
ƒƒ Wavelength 428 nm
Range
Detection Limit
Accuracy
Light Source
0-10 ppm, Free and Total Chlorine
0.00-5.00 ppm Range: 0.01 ppm; 5.0-10.0 ppm Range:
0.1 ppm
Tablet:
0-1.0 ppm Range: ±0.03 ppm
1.0-3.0 ppm Range: ±0.06 ppm
3.0-6.0 ppm Range: ±0.3 ppm
6.0-10.0 ppm Range: ±2.5 ppm
Liquid:
0-0.5 ppm Range: ±0.03 ppm
0.6-3.0 ppm Range: ±0.06 ppm
3.0-6.0 ppm Range: ±0.4 ppm
6.0-10.0 ppm Range: ±1.5 ppm
0.03 ppm
<5 Seconds
525 nm LED, complies with Standard Methods 4500-Cl G
0-1000 cu
20 cu
±15 cu
428 LED
Kits & Accessories
LTC-3000we US EPA Compliant, Order Code 1972-EPA, Turbidity (EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001),
Chlorine (Standard Methods 4500-Cl G), Color (based on Standard Methods 2120 C)
LTC-3000wi ISO Compliant, Order Code 1972-ISO, Turbidity (ISO 7027), Chlorine (Standard Methods 4500-Cl G), Color (based on
Standard Methods 2120 C)
0290-6
1480
1450
1451
1452
1453
1454
1455
6903A-J
Six pack of tubes
0 NTU/FNU Standard (EPA and ISO), 60 mL
1 NTU Standard (EPA), 60 mL
10 NTU Standard (EPA), 60 mL
100 NTU Standard (EPA), 60 mL
1 FNU Standard (ISO), 60 mL
10 FNU Standard (ISO), 60 mL
100 FNU Standard (ISO), 60 mL
Chlorine DPD #1 Tablets, 100
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
6197A-J
1901-CD
6195-H
4140-01
3176-02
6973-H
6973-L
3858-H
Chlorine DPD #3 Tablets, 100
SMARTLink3 Software
Formazin standard solution, 4000 NTU, 60 mL
DPD Chlorine secondary standards kit
FAS-DPD Titration kit for chlorine titration
Standard chlorine solution, 250 ppm, 60 mL
Standard chlorine solution, 250 ppm, 475 mL
Permanganate solution, 1000 ppm, 60 mL
13
Instrumentation
tm
SMART Spectro Spectrophotometer
A spectrophotometer that is easy to use and more accurate
than anything in its price range. With automatic wavelength
selection, pre-programmed tests, and superior performance
– this is the best spectrophotometer for the money!
Menu Driven Display
Tests and functions are selected from scrolling menus for ultimate simplicity. Results are displayed
as %T, absorbance, and concentration.
Pre-Programmed Tests, User Tests & Automatic Wavelength
Selection
Over 80 pre-programmed tests. Up to 25 calibrations for additional tests can be entered into the
memory. The user can also customize sequences for frequently run tests. The meter automatically
moves the grating to the required wavelength.
To Order:
Order Code 2000-01 (120V/60Hz and 220V/50Hz)
Includes 6 sample cells (25mm round), 2 sample cell holders (25mm round and COD, 10mm
cuvettes), power supply, battery charger, and diagrammed manual.
Options:
ƒƒ Carrying Case, Order Code 2000-CS
ƒƒ Battery Pack with holder (rechargeable), Order Code 2000-BP
ƒƒ SMARTLink 3 Software with cable, Order Code 1912-CD
ƒƒ Replacement sample cells (round) Order Code 0290-6
ƒƒ Cuvettes • Order Code 29653-10
14
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
tm
SMART Spectro Spectrophotometer
A wider
wavelength
range
The same
accuracy,
every test
Extremely
high
resolution
Better linearity
for higher
concentrations
Better for
higher
absorbance
samples
Better linearity
for higher
concentrations
350-1000 nm
±2 nm continuous
wavelength
accuracy
1 nm resolution
with 5 nm (max)
bandpass over
entire range
Modified Ebert
mounting, 1200
lines/mm grating
-0.1 to 2.5A
photometric range
±0.005A
continuous photometric
accuracy
Wavelength Range:
Wavelength Accuracy:
Wavelength Resolution:
Wavelength Bandwidth:
Photometric Range:
Photometric Accuracy:
Photometric Noise:
UNIQUE OPTICAL
SYSTEM DESIGN
using a 1200 lines/mm grating provides for an excellent
range, greater accuracy, and
high resolution.
Photometric Drift:
Photometric Stray Light:
Dispersive Device:
Optical Mount:
Grating:
Light Source:
Bulb Life:
Sample Chambers:
Detector:
Temperature Range:
Modes:
Pre-Programmed Tests:
Wavelength Selection:
User Tests:
Datalogging:
Diagnostics:
Power:
Weight:
Size (WxDxH:)
350-1000 nm
±2 nm
1 nm
5 nm (max)
0-125%T, -0.1-2.5A
±0.005A
<0.001A at 0A;
<0.002A at 2A
±0.002A/hr @500 nm
<0.5 %T
Grating - based system
Modified Ebert
1200 grooves/mm ruled
grating
Quartz halogen
1000 hours minimum
25 mm round cell, 10 mm
square cuvette UDV, COD
Silicon photodiode
0-40°C
Conc., %T, ABS
Yes
Automatic
Yes, up to 25 can be
entered and edited
Yes, RS-232, datalogs
500 tests
Yes
110/220 volt or battery
pack (rechargeable)
4.65 kgs (10.3 lbs)
35 cm x 28 cm x 17 cm
An
error-free
design
Much easier
to operate
A full function
display screen
Truly
superior
utility
A wider
wavelength
range
Wavelength
selection is fully
automatic
Menu prompting
with six-button
simplicity
Display %T, ABS,
concentration; 4
line, 40 character
Pre-programmed
tests, additional
25 user tests
Optional battery
pack, rugged
optical bench
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
15
Instrumentation
COD Reagents & Heater Blocks
Digestion Tubes for Total Nitrogen and Total
Phosphorus
LaMotte offers low and high Total Phosphorus and a Total Nitrogen test that are reacted
in a heater block and are then tested using a colorimeter or spectrophotometer.
Code
Description
Range
# of Tests
4024-01
Low Total Phosphorus
0-3.5 mg/L
25
4025-01
High Total Phosphorus
0-100 mg/L
25
4026-01
Total Nitrogen
0-25 mg/L
25
Multi-Range COD Reagent Systems
LaMotte-manufactured Chemical Oxygen Demand reagent systems used with our
SMART3 Colorimeter or SMART Spectro Spectrophotometer are an easy and precise way
to measure critical COD levels. Measure low, medium or high levels of COD using your
choice of mercury (US EPA approved method) or non-mercury reagent systems. Each
package contains 25 ready to use vials. All kits ship as R1.
Mercury based systems
Mercury-free systems
Code
Range
Code
Range
0075-SC
0-150 ppm (EPA approved)
0072-SC
0-150 ppm
0076-SC
0-1500 ppm (EPA approved)
0073-SC
0-1500 ppm
0077-SC
0-15,000 ppm
0074-SC
0-15,000 ppm
COD Heater Block
Code 5-0102 (120V), 12-tube capacity
Code 5-0102-EX2 (230V), 12-tube capacity
This COD heater block features digital microprocessor control, programmable time and
temperature settings, and a dual LED display to monitor both temperature and timer.
Perfect for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests requiring digestion.
Temperature:
Timer:
Vial Capacity:
Stability:
Weight:
Dimensions
CE Mark:
Oven Temp Cutoff:
16
30-200°C
0-999 minutes
12 (16 mm tubes)
±0.1°C@100°C
3.6 kg
310 x 250 x 80mm (LxWxH)
Yes
212°C
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
New tests are being developed for the SMART 3.
Please contact our Technical Service Department
for information regarding additions.
Instrument Reagent Listing
Test Factor
Test Method (# of reagents)
SMART 3
Range†
SMART 3
MDL†
Spectro Range†
Spectro
MDL†
#
Tests
Code
Ship
Alkalinity UDV
Unit Dose Vial (1)
0-200
10
0-200
15
100
4318-J
NH
Aluminum
Eriochrome Cyanine R (4)
0.00-0.30
0.01
0.00-0.30
0.01
50
3641-01-SC
NH
Ammonia Nitrogen LR, Fresh
Salicylate (3)
0.0-1.00
0.05
0.0-1.00
0.02
25
3659-01-SC
R2
Ammonia Nitrogen LR, Salt
Salicylate (3)
0.0-1.00
0.10
0.0-1.00
0.10
25
3659-01-SC
R2
Ammonia Nitrogen HR
Nesslerization (2)
0.00-4.00
0.05
0.00-4.00
0.05
50
3642-SC
R1
Barium
Barium Chloride (1)
0-200
—
—
50
3638-SC
NH
Benzotriazole
UV Photolysis (3)
0.0-30.0
1
0.0-30.0
1.0
50
4047-01
R1
Biguanide
Colorimetric (1)
0-70
7
0-70
5
50
4044
NH
Borate UDV
Unit Dose Vial (1)
0.00-80.00
5.0
—
—
100
4322-J
NH
Boron
Azomethine-H (2)
0.00-0.80
0.05
0.00-0.80
0.05
50
4868-01
NH
Bromine LR
DPD Tablets (2)
0.00-9.00
0.10
0.00-9.00
0.04
100
3643-SC
NH
Bromine UDV
Unit Dose Vial DPD (1)
0.0-20.0
0.35
0.0-20.0
0.3
100
4311-J
NH
Cadmium
PAN (4)
0.00-1.00
.025
0.00-1.00
0.02
50
4017-01
R1
Carbohydrazide
Iron Reduction (3)
0.000-0.900
.005
0.000-0.900
0.005
100
4857
R1
Chloride TesTab
Argentometric (1)
0.0-30.0
0.5
0.0-50.0
0.5
50
3693-SC
NH
Chlorine (Free & Total)
DPD Tablets (3)
0.00-4.00
0.05
0.00-4.00
0.02
100
3643-SC
NH
Chlorine - Free UDV
Unit Dose Vial (1)
0.00-10.00
0.15
0.00-10.00
0.10
100
4311-J
NH
Chlorine - Liquid DPD
DPD (3)
0.00-4.00
0.05
0-4
0.025
144
4859
R1
Chlorine - Total UDV
Unit Dose Vial (1)
0.00-10.00
0.15
0.00-10.00
0.10
100
4312-J
NH
Chlorine Dioxide
DPD Tablet/Glycine (2)
0.00-8.00
0.10
0-7.0
0.04
50
3644-SC
NH
Chromium Hexavalent
Diphenylcarbohydrazide (1)
0.00-1.00
0.02
0.00-1.00
0.01
50
3645-SC
HA
Chromium (Total, Hex &
Trivalent)
Diphenylcarbohydrazide (5)
0.00-1.00
0.05
0.00-1.00
0.03
50
3698-SC
HF
Cobalt
PAN (3)
0.00-2.00
0.025
0.00-2.00
0.02
50
4851-01
LQ
COD LR w/ Mercury*
Digestion (1)
0-150 mg/L
5 mg/L
0-150 mg/L
5 mg/L
25
0075-SC
R1
COD LR w/o Mercury*
Digestion (1)
0-150 mg/L
5 mg/L
0-150 mg/L
5 mg/L
25
0072-SC
R1
COD SR w/ Mercury*
Digestion (1)
0-1,500 mg/L
50 mg/L
0-1,500 mg/L
50 mg/L
25
0076-SC
R1
COD SR w/o Mercury*
Digestion (1)
0-1,500 mg/L
50 mg/L
0-1,500 mg/L
50 mg/L
25
0073-SC
R1
COD HR w/ Mercury*
Digestion (1)
0-15,000 mg/L
500 mg/L
0-15,000 mg/L
500 mg/L
25
0077-SC
R1
COD HR w/o Mercury*
Digestion (1)
0-15,000 mg/L
500 mg/L
0-15,000 mg/L
500 mg/L
25
0074-SC
R1
Color
Platinum Cobalt (0)
0-1,000
20
0-1,000
15
∞
NA
NH
Copper BCA
Bicinchoninic Acid (1)
0.00-3.50
0.04
0.00-3.50
0.05
50
3640-SC
NH
Copper Cuprizone
Cuprizone (2)
0.00-2.50
0.03
0.00-2.00
0.01
50
4023
R1
Copper DDC
Diethyldithiocarbamate (1)
0.00-7.00
0.05
0.00-6.00
0.05
50
3646-SC
NH
Copper UDV
Unit Dose Vial, Bicinchoninic
Acid (1)
0.0-4.0
0.5
0.00-4.00
0.20
100
4314-J
NH
Cyanide
Pyridine-Barbituric Acid (5)
0.00-0.50
0.01
0.00-0.50
0.05
50
3660-01-SC
R1
Cyanuric Acid
Melamine (1)
5-200
10
0-200
16
100
3661-01-SC
R1
Cyanuric Acid UDV
Unit Dose Vial Melamine (1)
5-150
6
0-150
5
100
4313-J
NH
DEHA
Iron Reduction (3)
0.00-0.700
0.005
0.00-0.700
0.005
100
4857
NH
Dissolved Oxygen (DO)
Winkler Colorimetric (3)
0.0-10.0
0.25
0.00-12.00
0.25
100
3688-SC
R1
Erythorbic Acid
Iron Reduction (3)
0.00-3.00
0.02
0.00-3.00
0.02
100
4857
R1
Fluoride
SPADNS (2)
0.00-2.00
0.05
0.00-2.00
0.05
50
3647-02-SC
R1
Hardness (Total), UDV
UDV (1)
0-450
15
10-500
10
100
4309-J
NH
0.000-0.750
0.010
50
3656-01-SC
R2
Hydrazine
P-dimethylaminobenzalde0.00-1.00
0.01
hyde (2)
†As ppm except as otherwise indicated *Requires COD Adapter Code 5-0087 and Heater Block
**UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Continue next page...
17
Instrumentation
Instrument Reagent Listing
Test Factor
Test Method (# of reagents)
Smart 3 Range
SMART 3
MDL
Spectro Range
Spectro
MDL
#
Tests
Code
Ship
Hydrogen Peroxide LR
DPD (2)
0.00-1.50
0.03
0.00-1.50
0.02
100
3662-SC
NH
Hydrogen Peroxide HR
DPD (2)
0.0-80.0
4
0-60
1
50
4045-01
NH
Hydrogen Peroxide Shock
DPD (2)
0-300
10
0-225
4
100
4045-01
NH
Hydroquinone
Iron Reduction (3)
0.00-2.00
0.01
0.00-1.80
0.01
100
4857
R1
Iodine
DPD Tablets (2)
0.00-14.00
0.20
0.00-14.00
0.08
100
3643-SC
NH
Iron
Bipyridyl (2)
0.00-6.00
0.06
0.00-6.00
0.06
50
3648-SC
R1
Iron UDV
Unit Dose Vial Bipyridyl (1)
0.00-10.00
0.2
0.00-10.00
0.07
100
4315-J
NH
Iron Phenanthroline
1,10 Phenanthroline (2)
0.00-5.00
0.08
0.00-4.50
0.04
50
3668-SC
R1
Lead
PAR (5)
0.00-5.00
0.10
0.0-5.0
0.1
50
4031-01
R1
Manganese LR
PAN (3)
0.00-0.70
0.02
0.00-0.50
0.02
50
3658-01-SC
HF
Manganese HR
Periodate (2)
0.0-15.0
0.3
0.0-15.0
0.3
50
3669-SC
R1
Mercury
TMK (3)
0.00-1.50
0.02
0.00-1.50
0.02
50
4861-01
LQ
Methylethylketoxime
Iron Reduction (3)
0.00-3.00
0.02
0-3.0
0.02
100
4857
R1
Molybdenum HR
Thioglycolate (3)
0.0-50.0
0.5
0.0-30.0
0.2
50
3699-03-SC
R1
Nickel
Dimethylglyoxime (6)
0.00-8.00
0.1
0.00-8.00
0.06
50
3663-01-SC
LQ
Nitrate Nitrogen LR
Cadmium Reduction (2)
0.00-3.00
0.10
0.00-3.00
0.05
20
3649-SC
R1
Nitrate TesTabs
Zinc Reduction (1)
0-60
5
0-60
2.5
500
3689-SC
NH
Nitrate UDV
Unit Dose Vial Zinc Reduction
0.00-80.00
0.0080.00
—
—
50
4321-J
NH
Nitrite Nitrogen LR
Diazotization (2)
0.00-0.80
0.02
0.00-0.80
0.02
20
3650-SC
NH
Nitrogen, Total*
Chromotropic Acid/Digestion (6)
3-25 mg/L
3 mg/L
0-25 mg/L
2 mg/L
25
4026-01
R1
Ozone
DPD (3)
0.00-3.00
0.03
—
—
100
4881
R1
Ozone LR
Indigo Trisulfonate (3)
0.00-0.40
0.02
0.00-0.40
0.02
100
3651-SC
NH
Ozone HR
Indigo Trisulfonate (3)
0.00-2.50
0.05
0.00-1.50
0.05
20
3651-SC
NH
pH CPR
Chlorophenol Red (3)
5.0-6.8
—
5-7
—
100
3700-01-SC
NH
pH PR
Phenol Red (3)
6.6-8.4
—
6.8-8.4
—
100
3700-01-SC
NH
pH TB
Thymol Blue (3)
8.0-9.6
—
8-9.5
—
100
3700-01-SC
NH
Phenol
Aminoantipyrine (3)
0.00-6.00
0.05
0.00-6.00
0.05
50
3652-01-SC
NH
Phosphate LR
Ascorbic Acid Reduction (2)
0.00-3.00
0.05
0.00-3.00
0.04
50
3653-SC
R2
Phosphate HR
Vanodomolybdophosphoric
Acid (1)
0.0-70.0
1
0.0-70.0
1
50
3655-SC
R1
Phosphate, ppb
Ascorbic Acid/Digestion (2)
0-3000 ppb
50 ppb
—
—
50
3653-SC
R2
Phosphorus, Total - LR*
Ascorbic Acid/Digestion (5)
0.00-3.50
0.10
0.00-3.00
0.07
25
4024-01
R1
Phosphorus, Total - HR*
Molybdovanadate/Digestion (5)
0.0-70.0
5.0
0-70
5.0
25
4025-01
R1
Potassium
Tetraphenylboron (2)
0.0-10.0
0.8
0.0-10.0
0.5
100
3639-SC
R1
Silica LR
Heteropoly Blue (4)
0.0-4.0
0.05
0.00-2.50
0.03
100
3664-SC
R1
Silica HR
Silicomolybdate (3)
0.0-75.0
0.5
0-50
1
50
3687-SC
R1
Sulfate HR
Barium Chloride (1)
0-100
4
5-100
5
100
3665-SC
R1
Sulfide LR
Methylene Blue (3)
0.00-1.50
0.025
0.00-1.00
0.02
50
3654-02-SC
R1
Surfactants
Bromphenol Blue (3)
0.00-8.00
0.75
0.0-8.0
0.5
100
4876-01
LQ
Tannin
Tungsto-Molybdophosphoric
Acid (3)
0.0-10.0
0.1
0.0-10.0
0.2
50
3666-01-SC
R1
Tolyltriazole
UV Oxidation/Dichromate (3)
0.0-30.0
1
0.0-30.0
1.0
50
4047-01
R1
Turbidity
Absorptimetric (0)
0-500 FAU
2 FAU
2-400 FTU
2 FTU
∞
NA
NH
Zinc LR
Zincon (6)
0.00-3.00
0.05
0.00-3.00
0.025
50
3667-01-SC
LQ
† As ppm except as otherwise indicated * Requires COD Adapter Code 5-0087 and Heater Block
** UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
18
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
Model 1200 • Single Test Colorimeter Labs
The 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance reliability,
improve accuracy, and simplify the calibration process, all in a portable, hand-held package.
Instrument Type:
Single wavelength,
direct-reading
colorimeter
Readout:
3½ digit LCD
Photometric Accuracy: ±0.001 Absorbance Unit
Detector:
Sample Chamber:
Light Source:
Interface:
Power:
Options:
RS-232 Cable (Order Code 1772)
AC Adapter 110/220V (Order Code 1754)
Accessories/Replacement Tubes (Order Code 0290-6)
Size (LxWxH):
Silicon Photodiode
Accepts 25mm diameter
flat-bottom, screwcap
tubes (6 included)
LED
RS-232 serial interface
Alkaline 9-volt DC battery,
3.5 mm jack for optional
AC adapter
15 x 8 x 5.5 cm,
6 x 3.25 x 2.5 inches,
152 x 83 x 64 mm
AUTO-ZERO
WATER RESISTANT DESIGN
FIELD & LAB USE
Simply insert the sample blank and press the
zero key. No more dialing in the zero
Designed with excessive exposure to moisture in
mind, the 1200 colorimeters deliver trouble-free
performace in the field and lab.
An optional AC adapter is available to save battery life when in the laboratory.
EPA COMPLIANT
No need to select a low or high range. The 1200
covers the entire critical chlorine range of 0-4
ppm with a 0.05 sensitivity.
HINGED LIGHT COVER
Flip-top lid over sample chamber prevents any
stray light, especially in the field, and avoids misplacing separate light caps.
IMPROVED ACCURACY
The microprocessor enables the factory programmed calibrations to optimally match nonlinear curves.
EUROPEAN CE MARK
The 1200 has been independently tested and
has earned the European CE Mark of compliance
for electromagnetic compatibility and safety.
Employing the proper wavelength and the DPD
test method, the 1200 Chlorine Colorimeter Kit
meets or exceedsEPA design specifications for
NPDWR and NPDES chlorine monitoring programs (EPA 330.5 and Standard Methods 4500Cl G).
0-4 PPM CHLORINE
RS-232 INTERFACE
An RS-232 port is provided to interface with a
datalogger or computer. Optional cable available.
A GREAT VALUE!
LARGE DISPLAY
Complete, economical package! The 1200 Chlorine Colorimeter Kit comes with enough tablets
for 100 tests or liquid reagents for 140 tests,
six sample vials with screw caps, instruction
manual, and sturdy coloring case.
The large 3½ digit display presents measurements in absorbance, and indicates low battery
warnings.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
19
Instrumentation
Model 1200 • Single Test Colorimeter Labs
Test Factor
Code
Model
Range
(ppm)
Detection
Limit
Test Method (# of reagents)
# of
Tests
Ship
Codes
Ammonia Nitrogen
Bromine
Chlorine (Free & Total)
3680-01
3672-01
3670-01
DC1200-NH
DC1200-BR
DC1200-CL
0–5.0
0–7.0
0–4.0
0.05
0.05
0.05
Nessler (2)
DPD Tablets (1)
DPD Tablets (2)
60
100
100
R1
NH
NH
Chlorine (Free & Total)
Chlorine Dioxide
Chlorine Dioxide
Copper
Fluoride
Iron
Manganese
Molybdenum
Nitrate Nitrogen
Ozone
Ozone (Without other oxidizers)
Phosphate
Sulfate
3670-01-LI
3671-01
3671-01-LI
3673-01
3674-01
3681-01
3682-01
3676-01
3677-01
3678-01
3598
3679-01
3683-01
DC1200-CL-LI
DC1200-CLO
DC1200-CLO-LI
DC1200-CO
DC1200-FL
DC1200-FE
DC1200-MN
DC1200-MO
DC1200-NA
DC1200-OZ
DC1200-OZ-DPD
DC1200-PLR
DC1200-SU
0–4.0
0–7.0
0-7.0
0–6.0
0–2.0
0–4.0
0–0.7
0–30
0–3.0
0–0.4
0-3
0–3.0
0–100
0.05
0.05
0.05
0.03
0.028
0.25
0.02
0.5
0.05
0.04
0.03
0.07
1.0
DPD Liquid (3)
DPD with Glycine Solution (2)
DPD Liquid
Diethyldithiocarbamate (1)
Alizarin-Zirconyl (2)
1,10 Phenanthroline (2)
PAN (3)
Thioglycolate (3)
Cadmium Reduction (2)
Indigo Blue (3)
DPD Liquid
Ascorbic Acid (2)
Barium Chloride (1)
140
100
140
100
100
100
100
50
40
100
140
100
100
R1
NH
R1
NH
LQ
R1
R3
R3
R1
NH
R1
R2
R1
Replacement Reagents for 1200 Chlorine
Liquid Reagents
30 mL
(1 oz.)
DPD 1A
DPD 1B
DPD 3
Code
Ship
Code
P-6740-G
P-6741-G
P-6743-G
NH
R2
NH
60 mL
(2 oz.)
DPD 1A
DPD 1B
DPD 3
Code
Ship
Code
P-6740-H
P-6741-H
P-6743-H
NH
R2
NH
Tablet Reagents
Tablet
Chlorine DPD #1 Instrument*
Chlorine DPD #3 Instrument*
Chlorine DPD #4 Instrument*
50
6903A-H
6197A-H
6906A-H
100
1000
6903A-J 6903A-M
6197A-J 6197A-M
6906A-J 6906A-M
Ship
Code
NH
NH
NH
* Instrument DPD featuring new ultra-clear fast dissolving tablets.
DPD Powder Pop® Dispenser
LaMotte now offers the Powder Pop Dispenser – a hand held, single-dose dispenser for 10 mL samples that delivers a
precise pre-measured dose of DPD reagent directly to your sample. Each Powder Pop kit includes enough reagent for
400 tests.
To Order:
Free Chlorine Powder Pop Dispenser (Order Code 3-0032)
Total Chlorine Powder Pop Dispenser (Order Code 3-0033)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
20
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
Model 1200 & 1200 UDV • Absorbance Colorimeters
Model 1200 & 1200 UDV • Absorbance Colorimeters
The versatile 1200 Series of single wavelength colorimeters now comes with the capability to display readings
directly in absorbance units. Six different wavelengths are available, with two sample vial options, to provide
maximum flexibility for your analytical procedures. Microprocessor control and advanced design assure accuracy,
easy operation, and durability.
Absorbance colorimeter kits are supplied with vials or cuvettes, water sample collecting bottle, 3 mL syringe
(1200-UDV only), all in a sturdy carrying case.
Model 1200 Meter
For 25mm vials
Order Codes
Listed by wavelengths:
3627-420
Model 1200-UDV
Meter
For 10mm cuvettes
Order Codes
Listed by wavelengths:
3627-420-UDV
3627-510
3627-460-UDV
3627-530
3627-510-UDV
3627-562
3627-530-UDV
3627-570
3627-562-UDV
3627-605
3627-570-UDV
Instrument Type:
Single wavelength, absorbance
colorimeter
Measurement
420nm, 460nm, 510nm,
Wavelengths:
530nm, 562nm, 570nm, or
605nm
Readable Resolution:
0.01 Absorbance Unit
Photometric Precision: ±0.001 Absorbance Unit
Range:
Display:
Response Time:
Detector:
Sample Chamber:
3627-605-UDV
Light Source:
Interface:
Power:
0-2.00 Absorbance Units
3½ digit LCD
2 seconds
Silicon Photodiode
Meters are available with one
of two chambers to accept
25mm flat-bottomed glass
vials (1200) or 10 mm square
polystyrene cuvettes (1200UDV)
LED
RS-232 serial interface, 8 pin
mDIN, 9600b, 8 data bits, 1
stop bit, no parity
Battery Operation: Alkaline
9-volt DC battery; Line
Operation: 120V/60Hz,
230V/50Hz with adapter
Chlorine Standards for Model 1200
For use with the 1200 series of chlorine colorimeters. Secondary standards provide a fast way to check
calibration without the burden of making primary standards. Based on Standard Methods for the Examination of Water and Wastewater, the operator can calibrate a colorimeter using a permanganate primary
standard or a chlorine primary standard. Once the meter is calibrated using the primary standard, the
operator can insert secondary standards periodically to evaluate the calibration of the instrument.
ƒƒ Secondary standard kit contains a blank and 3 standards for low, mid-range, and high chlorine
calibrations.
ƒƒ Packaged in a small plastic case with Certificate of Analysis stating range of each standard.
To Order:
DPD Chlorine Secondary Standards, Order Code 4140-01
FAS-DPD Titration Kit for Chlorine Titration, Order Code 3176-01
Standard Chlorine Solution, 250 ppm, Order Code 6973-H (60 mL)
Order Code 6973-L (475 mL)
Permanganate Solution, 1000 ppm, Order Code 3858-H (60 mL)
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
21
Instrumentation
TRACER PockeTesters
The world’s first pocket-sized ISE meter for measuring total chlorine.
Use it to test pH and ORP with interchangeable flat surface sensors.
Total Chlorine TRACER
Order Code 1740
ƒƒ Read Total Chlorine from 0.00-10 ppm
ƒƒ Readings are not affected by sample color or turbidity
ƒƒ Automatic self calibration
ƒƒ Extra bold display includes an analog bar graph feature
ƒƒ Memory can store up to 15 readings
ƒƒ Chlorine and pH modes also display sample temperature
ƒƒ Unit identifies which probe is in use and retains calibrations
ƒƒ Automatic shut-off and Low Battery indicator; uses four 3V CR-2032 batteries
ƒƒ Includes 100 reagent tablets at almost half the price of similar Chlorine ISE reagents
ƒƒ Follows EPA protocol for ISE methods
pH TRACER
ORP TRACER
Order Code 1741
Provided with 4, 7, and 10 pH buffer tablets
Order Code 1742
ƒƒ Rugged flat surface electrode will alert user when it’s
time to “RENEW”
ƒƒ A “CAL” indicator shows when to recalibrate and user can
select a 1, 2, or 3 point calibration
ƒƒ Includes Automatic Temperature Compensation and
ƒƒ High resolution to 1 mV
ƒƒ Automatic self calibration
Range:
Resolution:
Accuracy:
-999 to 999 mV
1 mV
±4 mV
displays temperature while showing pH result
Range:
Temp:
Resolution:
Accuracy:
0.00 to 14.00 pH
32° to 149°F (0° to 65°C)
0.01 pH
±0.01 pH
OPTIONS
Additional Probes
Order Code 1733 pH Sensor
Order Code 1734 ORP Sensor
Order Code 1732 Cl2 Sensor
0-14.00/±0.01 pH
±999mV/±4mV
0-10.00/±10% of reading
Chlorine Test Tablets
Order Code 7044A-J
Specially formulated just for the TRACER, these deliver a precise amount of iodide for a 20 mL sample.
Available in packages of 100.
22
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
TRACER PockeTesters
EC/TDS/SALT TRACER
Flouride TRACER
Code 1749
ƒƒ Easy to use
ƒƒ 2% accuracy for EC, TDS, and Salt modules
ƒƒ Automatic temperature compensation
ƒƒ Self calibration
ƒƒ Memory can store up to 25 readings; auto-power off
Code 1756
ƒƒ The first Fluoride meter with built-in
after 10 minutes of no button presses
ƒƒ Automatic shut-off and low battery indicator; uses
four 3V CR-2032 button batteries
ƒƒ Small sample/TISAB volume required for
testing
ƒƒ Complies with EPA Method 340.2
(Potentiometric Ion Selective Electrode)
ƒƒ Automatic electronic 1 or 2 point calibration
with offset adjustment
Options:
ƒƒ Memory stores 25 labeled readings and
EC/TDS/SAL Replacement Electrode*, Order Code 1765
ƒƒ Complete with electrode, 20 TISAB reagent
Sample Cup w/cap, Order Code 1745-1
Conductivity Standard, 84 µS, Order Code 6312-G
Conductivity Standard, 1413 µS, Order Code 6354-J
Conductivity Standard, 12,880 µS, Order Code 6317-G
Conductivity:
*Not interchangeable
with Cl/pH/ORP TRACER
Automatic Temperature Compensation
and fastest response (<1 min)
TDS:
Salinity:
Temperature
Accuracy:
0 to 199.9 µS, 200 to 1999 µS,
2.00 to 19.99 mS
0 to 9,999 ppm
0 to 9,999 ppm
32°F to 149°F (0 to 65°C)
EC, TDS, Salt: ± 2% FS;
Temperature: ± 1°C (1.8°F)
water resistant to IP54
tablets, sensor cap, four 3V button
batteries, and 48” (1.2m) neckstrap
Options:
TISAB Reagent, 100 Tablets, Order Code 7024-J
Replacement Electrode, Order Code 1757
Fluoride Standard, 1 ppm, 1000 mL,
Order Code 2798-M
Fluoride Standard, 1,000 ppm, 60 mL,
Order Code 4154-H
Fluoride Standard, 1,000 ppm, 500 mL,
Order Code 4154-L
Fluoride:
Temperature
pH/TDS/SALT
Accuracy:
0.1 to 10 ppm, max. resolution: 0.1
ppm, accuracy: ±3% rdg
32°F to 140°F (0 to 60°C), max.
resolution: 0.1 °F, accuracy:
±1.8°F/1°C
EC, TDS, Salt: ± 2% FS; Temperature:
± 1°C (1.8°F)
Code 1766
ƒƒ Measures five parameters including Conductivity, TDS, Salinity, pH, and Temperature using one electrode
ƒƒ Units of measure: pH, µS, mS, ppm, ppt, mg/L, g/L, °C, °F
ƒƒ Memory stores up to 25 labeled readings; auto power off and low battery indicator
ƒƒ Adjustable Conductivity to TDS ratio
Options:
pH/EC/TDS/SAL Replacement Electrode*
Order Code 1755
Sample Cups w/cap
Order Code 1745-1
Conductivity Standard, 84 µS
Order Code 6312-G
Conductivity Standard, 1413 µS Order Code 6354-G
Conductivity Standard, 12,880 µS
Order Code 6317-G
Conductivity
TDS/Salinity
pH
Temperature
Range
Resolution
Accuracy
0 to 199.9 µS, 200 to 1999 µS, 2.00 to 19.99 mS
0 to 99.9 ppm (mg/L), 100 to 999 ppm (mg/L), 1.00 to 9.99 ppt
0.00 to 14.00 pH
32° to 149°F (0 to 65°C)
0.1 µS
0.1 ppm (mg/L)
0.01 pH
0.1°F/°C
±1%
±2%
±0.01 pH
±1.8°F/°C
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
23
Instrumentation
Dissolved Oxygen Meters
Dissolved Oxygen Tracer
Order Code 1761
ƒƒ Oxygen level displayed as % Saturation from 0 to 200.0% or Concentration from 0 to 20.00 ppm (mg/L)
ƒƒ Adjustable Altitude Compensation (0-20,000 ft in 1,000 ft increments)
ƒƒ Adjustable Salinity Compensation from 0 to 50 ppt
ƒƒ Memory stores up to 25 data sets with DO and Temperature reading
ƒƒ Self-calibration on power up; Data, Hold, Auto power off, Low battery indicator
ƒƒ Waterproof to IP67
ƒƒ Optional 3 ft (1m) or 16 ft (5m) extension cable
ƒƒ Complete with DO electrode, protective sensor cap, spare membrane cap, electrolyte, four 1.5V CR-2032 batteries,
and 48” (1.2m) neckstrap
Range
DO (sat. mode)
DO (conc. mode)
Temp.
Dimensions
Weight
Resolution
Accuracy
0 to 200.0%
0.1%
0 to 20.00 ppm (mg/L)
0.01 ppm (mg/L)
32 to 122°F (0 to 50°C)
0.1°F/°C
1.4x6.9x1.6” (36x176x41mm)
3.8 oz (110g)
±2% FS
0.4 ppm (mg/L)
±1.8°F (1°C)
Accessories
ƒƒ DO Membrane Kit, 6 screw-on membranes and solution (Order Code 1761M)
ƒƒ DO Sensor Module,(Order Code 1762)
Dissolved Oxygen Meter
Order Code 5-0107-01
ƒƒ No meter warm-up required
ƒƒ Low-maintenance probe
ƒƒ Key in salinity and pressure values manually
ƒƒ Independent 100% and zero adjustment calibrations
ƒƒ Offset adjustment capabilities
ƒƒ Displays electrode diagnostics
ƒƒ Easily toggle from
mg/L (ppm) or
% saturation to
temperature
mode
Range
Resolution
Accuracy
0.00 to 20.00 mg/L
(ppm)
0.0 to 200.0%
-5.0 to 105.0°C
0.0 to 50.0 ppt
0.01 mg/L
(ppm)
0.1%
0.1°C
0.1 ppt
±1.5% FS
Barometric pressure
correction
500 to 1499 mm Hg
1 mm Hg
Temperature
compensation
Operating temperature
Probe
Power
Automatic from 0 to 50°C
mg/L (ppm)
% Saturation
Temp.
Salinity correction
Dimensions
Weight
±1.5% FS
±0.5°F
Method: Key
in manually
or automatic
correction
Method: Key
in manually
or automatic
correction
0 to 50°C
Galvanic, 3 ft. probe cable
Four 1.5 V AAA batteries (included), >700 hrs
continuous use
5.5”L x 2.7”W x 1.3”H
1.0 lb (0.45 kg)
Accessories
ƒƒ Replacement Probe (Order Code 5-0129)
ƒƒ Replacement Membrane Package including electrolyte solution
(Order Code 5-0137)
24
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
PockeTesters
27
PAGE
for complete PockeTester specs
pH PockeTester 10
Order Code 5-0103 (Replacement Electrode, Code 5-0097)
ƒƒ ±0.1 pH accuracy
pH PockeTester 20
Order Code 5-0104 (Replacement Electrode, Code 5-0097)
ƒƒ ±0.01 pH accuracy
Both meters feature automatic temperature compensation, and buffer recognition for three
point calibration based on US (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18) systems. The
sensor is a double junction Ag/AgCl system with polymer gel. The IP67 rated housing features
a 1.0625” (26.99 mm) display, which also displays diagnostic messages. Auto-off after 8.5
minutes to conserve battery life.
Double Junction ORP PockeTester
Order Code 5-0079
ƒƒ –999 mV to +1000 mV
ƒƒ Large surface area platinum band sensor
ƒƒ 1 mV resolution, 2 mV accuracy
ƒƒ HOLD function, Auto-off
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
25
Instrumentation
PockeTesters
Code 5-0078
Code 5-0080
Microprocessor-Based TDS
Dual Range PockeTester
Order Code 5-0080
ƒƒ 0-2000 ppm (10 ppm resolution) ; 0-10.00
ppt (0.10 ppt resolution)
ƒƒ ±1% full-scale accuracy
ƒƒ Automatic temperature compensation (ATC)
ƒƒ Replacement electrode
ƒƒ Push-button calibration
ƒƒ Auto shut-off
ƒƒ Full reading displayed – no need to multiply
26
Salt PockeTester
Order Code 5-0078
ƒƒ 0–10 ppt ( 0.10 ppt resolution)
ƒƒ Carrying Case and calibration standard
included
Code 5-0082
Microprocessor-Based EC
Conductivity Dual Range
PockeTester
Order Code 5-0082
ƒƒ 0-2000 µS (10 µS resolution); 0-20.00 mS
(0.10 mS resolution)
ƒƒ ±1% full-scale accuracy
ƒƒ Automatic temperature compensation (ATC)
ƒƒ Replacement electrode
ƒƒ Push-button calibration
ƒƒ Auto shut-off
ƒƒ Full reading displayed – no need to multiply
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
PockeTester Specifications
Specifications for pH PockeTesters
Model
Code
Range
Specifications for Specialty PockeTesters
pH PockeTester 10
pH PockeTester 20
5-0103
5-0104
–1.0 to 15.0 pH; extended range
Min-Max Thermometer
5-0095
–10 to 200°F,
14 to 392°C
ORP PockeTester
5-0079
–999 mV to +1000 mV
Salt
5-0078
0-10.00 ppt salinity
0.1°F to 199.9°,
1°C above 200°
±1.8°F / ±1.0°C
1 mV
0.10 ppt salinity
±2 mV
Factory calibrated; fine
adjustment through keypad
Offset calibration to ORP
standard or work standard
±10%
full-scale
One-point with
trimpot
32 to 122°F;
0 to 50°C
32 to 122°F;
0 to 50°C
32 to 122°F;
0 to 50°C
Automatic (ATC)
0 to 50°C
—
—
Automatic(ATC)
0 to 50°C
Special
Functions
On/Off or Auto-Off after 8.5 min.; HOLD; CALibrate;
CONfirm
On/Off or Auto-Off after 8.5
min.; CALibrate; CONfirm;
HOLD (HO) and HOLD/
CANCEL (HC)
Power &
Battery Life
Four 1.5V alkaline button cell batteries (supplied),
500 hour use
On/Off or Auto-Off after 8.5
min.; HOLD; °F or °C scale
selectable; factory calibration
maintained when batteries are
replaced
LR-44 button cell. 2 yr life
Resolution
0.1 pH
0.01 pH
Accuracy
±0.1 pH
±0.01 pH
Calibration
Select up to 3 points
(4.0, 7.0, 10.0 or 4.01, 6.86, 9.18)
Operating
Temperature
32 to 122°F;
0 to 50°C
Temperature
Compensation
Dimensions &
Weight
Model
32 to 122°F;
0 to 50°C
Four 1.5V alkaline batteries
(supplied) 500 hrs. use
Four 1.5V alkaline
batteries (supplied)
150 hrs. use
8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed); 6.5” (165 mm) L x 1.5” (38 mm) Dia. (unit only);
4.5 oz/125 gms (boxed); 3.25 oz./90 gms (unit only)
Memory Thermometer Probe: 4.3” (109 mm) x 0.14” (4 mm); top is 1.8” (46 mm); weight 3 oz
Specifications for TDS & EC Waterproof PockeTesters
TDS Dual Range
EC Dual Range
Code
5-0080
5-0082
Replacement Electrode
5-0084
5-0084
0-2000 ppm/ 0-10 ppt
0-2000 µS; 0 to 20 mS
Range
Resolution
10 ppm/0.10 ppt
Accuracy
Calibration
10 µS; 0.10 mS
±1%FS
One-point, push-button calibration using buttons inside battery compartment
Operating Temp.
32 to 122°F; 0 to 50°C
Temperature Comp.
Automatic (ATC) 0 to 50°C
Special Functions
Full reading displayed
Power & Battery Life
Four 1.5V alkaline batteries (supplied); 150 hours
Dimensions & Weight
8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed);
6.5” (165 mm) L x 1.5 (38 mm)” Dia. (unit only);
4.5 oz./125 gms (boxed); 3.25 oz./90 gms (unit only)
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
27
Instrumentation
Temperature Measurement
IR Meter with Color Alert System
Code 5-0133
Convenient non-contact temperature measurements, now with a laser
sighting, plus color and sound alerts!
Features
ƒƒ Fast and accurate measurements at 12” where the two lasers
converge with 12:1 field of view
ƒƒ Measures up to 950°F (510°C)
ƒƒ Blue backlit dual LCD display changes to Red backlit outside set
points
ƒƒ Instantaneous response captures spikes in temperature
ƒƒ Max mode captures and holds rapidly changing temperatures
ƒƒ Lock function for continuous readings
ƒƒ Adjustable emissivity increases measurement accuracy for different
surfaces
ƒƒ Double molded housing
ƒƒ Complete with case and 9V battery
ƒƒ Adjustable High/Low set points with color and audible alarms signal
out of range temperature
Range:
Resolution:
Accuracy:
Blue backlight:
within temperature
range
Red backlight
plus audible
alert: exceeds
temperature
Repeatability:
Response Time:
Emissivity:
Distance-to-Spot Size:
Power:
Dimensions:
Weight:
-4 to 950°F (-20 to 510°C)
1°C/1°F
25 to 260°C (77 to 500°F): ±(1% of rdg
+2°F/1°C)
±0.5% or 1.8°F/1°C
150mSec
0.10 to 1.00 adjustable
12:1
One 9V alkaline battery
5.7 x 4 x 1.6 inches (146 x 104 x 43 mm)
5.74 oz. (163g)
“Min-Max” Memory Thermometer
Order Code 5-0095
ƒƒ Range: 14 – 392°F or -10 – 200°C
ƒƒ °F or °C selectable scale
ƒƒ Recalls minimum and maximum temperature
28
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
Economical Field Meters
LaMotte pH, CON, TDS Meters
ƒƒ Push button operation
ƒƒ Up to five point calibration
ƒƒ Temperature readout
ƒƒ Automatic Temperature Compensation
ƒƒ Auto-off after 17 minutes
ƒƒ Hold function
ƒƒ Buffer recognition (pH 5 meter)
ƒƒ Adjustable conductivity to TDS factor (TDS 6 meter)
Microprocessors have enabled meter manufacturers to combine many features into
smaller designs with better accuracy. The 5 and 6 Series meters are good examples
(see specifications below). All meters include electrodes and temperature probes,
and are available with or without a carrying case.
ƒƒ The pH 5 without case includes pH 4, 7 and 10 buffer tablets.
ƒƒ The pH 5 with case includes pH 4, 7 and 10 buffer liquids.
ƒƒ The TDS 6 and Con 6 with carrying cases include two calibration standards.
ƒƒ All meters have two-year warranties.
pH 5
(Temperature)
CON 6 Meter
(Conductivity)
TDS 6 Meter
(TDS)
w/out case 5-0034
with case 5-0035
0.00 to 14.00 pH
0.0 to 100.0°C
w/out case 5-0038-01
with case 5-0039-01
0.0 to 20.00,
200, 2,000.0 µS
0 to 20.00, 200.0 mS
Resolution:
0.01 pH
0.1°C
Accuracy:
±0.01 pH
±0.5°C
w/out case 5-0036-01
with case 5-0037-01
0.0 to 10.00,
100.0, 1000 ppm
1.0 to 10.00,
100.0, 200 ppt
0.01, 0.1, 1.0 ppm
0.01, 0.1 ppt
±1% full scale
Model
Order Code
Range:
Calibration:
Temperature
Compensation:
Power:
Display:
Auto shut-off:
Operating
Temperature:
pH 5
(pH)
Up to 5 Buffer Values
Offset 0.1°C
increments
Automatic Temperature Compensation
(ATC)
Four AAA alkaline batteries (supplied);
>70 hours continuous use
Single Custom LCD
After 17 minutes
32 to 122°F; 0 to 50°C
0.01, 0.1, 1 µS
0.01, 0.1 mS
±1% full scale
or ±1 digit
up to 5 points (1 per range) for multi-point calibration; or 1
point for single point for entire range
Automatic Temperature Compensation (ATC)
fixed 2% per °C factor, adjustable 73%
Four AA alkaline batteries (supplied)
>100 hours continuous use
Single Custom LCD
After 17 minutes
32 to 122°F; 0 to 50°C
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
CON 6 & TDS 6
Meters
(Temperature)
-10.0 to 110.0°C
0.1°C
±0.5°C
Offset 0.1°C
increments
29
Instrumentation
pHPLUS Direct Digital pH/ISE Meter
pHPLUS DIRECT Meter
Laboratory precision in a water-resistant design!
Read pH, mV/R.mV, temperature, and concentration
with accuracy – ISEs read concentration in ppm. Easyto-use in any test mode. Includes pH probe, temperature
probe, buffers and rubber boot with stand.
Specifications
pH
Range:
Resolution:
Accuracy:
Calibration:
Electrode:
Temperature
0.00 to 14.00
0.01
0.01
Up to 5 points
Epoxy, Ag/AgCl
Range:
Resolution:
Accuracy:
Concentration
0 to 100°C
0.1°C
±0.1°C
Range:
Resolution:
Accuracy:
mV/R.mV
0.00 to 100
± LSD
±0.5% or ±1 LSD
Range:
Accuracy:
Resolution:
Calibration:
Inputs:
±500mV
±1 mV
1 mV
Up to 5 points
1 BNC, Temp probe, power, ref. pin
Power:
Size (LxWxH):
4 AAA batteries
2.75W x 5.75H x 1.375D in.
pHPLUS DIRECT Meter
Code
Description
5-1936
pHPLUS DIRECT Meter, liquid buffers
(4, 7, 10) w/case
pH Electrode, gel-filled
Temperature Probe
1904
1909
30
Optional ISE Electrodes
Although the pHPLUS Direct reads directly in ppm, an initial calibration is
required. The standard solution, replacement electrolyte, ionic strength adjustor and pipet are included in the Accessory Kit. The ammonia accesory kit
also contains replacement membranes.
Accessory Kits
Ion Selective Electrodes
Code
Description
Code
Description
5-0098
5-0099
5-0100
Ammonia
Fluoride
Nitrate
5-0043
5-0048
5-0052
Ammonia
Fluoride
Nitrate
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
DPD Reagents
Quantity/Order Code
DPD TesTabs Instrument Grade
®
Tablet
LaMotte has developed a rapid dissolve instrument grade
DPD tablet system. Instrumental analyses require a clear,
particle-free testing solution. In the past, it was necessary to
use a crusher to dissolve the instrument grade tablets. Now,
free and total chlorine samples can be done with instrument
grade tablets that dissolve without crushing.
50
100
1000
Chlorine DPD #1 Rapid
6999A-H
6999A-J 6999A-M
Chlorine DPD #1
6903A-H
6903A-J 6903A-M
Instrument*
Chlorine DPD #3 Rapid
6905A-H
6905A-J 6905A-M
Chlorine DPD #3
6197A-H
6197A-J 6197A-M
Instrument*
Chlorine DPD #4 Rapid
6899A-H
6899A-J 6899A-M
Chlorine DPD #4
6906A-H
6906A-J 6906A-M
Instrument*
pH (Phenol Red)
6915A-H
6915A-J 6915A-M
Alk Test
3920A-H
3920A-J 3920A-M
Cyanuric Acid
6994A-H
6994A-J 6994A-M
Calcium Hardness
6846A-H
6846A-J 6846A-M
MPS-OUT
6911A-H
6911A-J
N/A
(Monopersulfate
Eliminator)
* Instrument DPD featuring ultra-clear fast dissolving tablets.
Ship
Code
NH
NH
NH
NH
NH
NH
NH
NH
NH
NH
NH
DPD Liquid Reagents
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators or
colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available Chlorine.
DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents are also available
to measure pH, Hardness, Alkalinity, and Copper.
30 mL (1 oz.)
Code
DPD 1A
DPD 1B
DPD 3
P-6740-G
P-6741-G
P-6743-G
Ship Code
NH
R2
NH
60 mL (2 oz.)
Code
DPD 1A
DPD 1B
DPD 3
P-6740-H
P-6741-H
P-6743-H
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Ship Code
NH
R2
NH
31
Instrumentation
pH Buffers/Electrode Soaker
Standardized
pH Buffer Solutions
Color-Coded
pH Buffer Solutions
For use in calibration of pH meters. Ordering information for all buffers is
listed below.
Minute amount of color permits immediate visual distinction of
different buffer values.
pH
Value
4.01
6.86
Code
Size
2866-J
2866-L
2808-L
120 mL
500 mL
500 mL
Note: Other pH values available
pH
Value
7.00
9.18
10.00
Code
Size
2881-J
2881-L
2809-L
120 mL
500 mL
120 mL
2896-J
2896-L
120 mL
500 mL
Buffer Tablets
Add one tablet to 20 mL of Deionized Water to produce buffers. Available in 50
and 100 tablet packs. In foil strips of 10 tablets each.
32
pH Value
Code
4.0
4.0
7.0
7.0
10.0
10.0
3983A-J-100
3983A-H-50
3984A-J-100
3984A-H-50
3985A-J-100
3985A-H-50
pH Value
Code
Color
Size
4.01
7.00
10.0
3771-L
3772-L
3773-L
Red
Yellow
Blue
500 mL
500 mL
500 mL
Electrode Soaker
Bottle
Order Code 0668
Continuously soaks pH electrode in a storage solution to
prevent probe dry out. Twist
top “O” ring seal prevents
leaks.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Instrumentation
Conductivity Solutions
Conductivity/TDS Solutions
The following potassium chloride solutions can be used to standardize
conductivity meters. TDS values are based on a 0.7 conversion from
conductivity.
Code
Description
Size
6416-L
6312-L
6417-L
6354-L
6418-L
6317-L
6419-L
74 µS/cm, 52 ppm
84 µS/cm, 59 ppm
718 µS/cm, 503 ppm
1,413 µS/cm,989 ppm
6,668 µS/cm, 4668 ppm
12,880 µS/cm, 9016 ppm
58,640 µS/cm, 41,048 ppm
500 mL
500 mL
500 mL
500 mL
500 mL
500 mL
500 mL
Conductivity Neutralizing Solutions
Used to neutralize hydroxl ion in boiler water, thus enabling accurate determinaion of ionic conductivity.
Code
Description
6483-H (60 mL)
6483-L (500 mL)
6483-N (3800 mL)
Conductivity
Neutralizing
Solution
Contains citric acid and phenolphthalein.
Add liquid until sample changes color.
Available in 60 mL, pint, and gallon sizes.
6479
Gallic Acid
Powder
Organic acid powder; indicator must be
purchased and added separately. Add raw
powder to sample containing indicator
until color changes. Available in 100 g.
3705
Acid Indicator
Contains acetic acid and phenolphthalein.
Add liquid until sample changes color.
Available in 500 mL (pint).
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
33
Insta-TEST® Test Strips
Convenient, economical
LaMotte offers a convenient, economical way to perform spot checks for several water quality factors. LaMotte test strips are a great way to monitor
water without having to use reagents or field kits. Strips are available for the factors below…and we’re working on more!
Single Factor Test Strips
Test Factor
Code
Range (ppm)
Water Testing Application*
# of Tests Per
Factor/Per Vial
Alkalinity
2997
0-180
Drinking, Food/Beverage
50
0, 40, 80, 120, 180
Borate
3017-G
0-80
Pool
25
0, 15, 30, 50, 80
Chlorine Dioxide
2999LR
0-10
Drinking, Food/Beverage
50
0, 0.25, 0.5, 1, 3, 10
Chlorine Dioxide
3002
0-500
Medical, Food/Beverage
50
0, 10, 25, 50, 100, 250, 500
Chlorine, Free, Low Range
2964-G
0-10
Drinking, Food/Beverage, Medical
25
0, 0.5, 1, 3, 5, 10
Chlorine, Total, Low Range
2963LR-G
0-10
Drinking, Food/Beverage, Medical
25
0, 0.25, 0.5, 1, 3, 10
Chlorine, High Range
3031
0-800
Drinking, Food/Beverage, Medical
50
0, 50, 100, 250, 500, 800
Chlorine, Total
2979
0-5
Drinking, Food/Beverage
50
0, 0.5, 1, 3, 5
Copper
2991-G
0-3.0
Drinking, Pool
25
0, 0.3, 0.6, 1, 3
Hardness, Low Range
2981
0-180
Drinking, Food/Beverage
50
0, 30, 60, 120, 180
Molybdenum Kit*
3628
0-5
Industrial
50
0, 0.5, 1, 2, 5
Nitrate
3012-G
0-200
Pool
25
0, 10, 30, 60, 120, 200
pH, Wide Range
2974
4-10 (pH)
Drinking, Food/Beverage
50
4, 5, 6, 7, 8, 9, 10
Peracetic Acid
3000
Values (ppm)
0-160
Food/Beverage
50
0, 10, 20, 50, 85, 160
Peracetic Acid, Low Range 3000LR
0-50
Food/Beverage
50
0, 5, 10, 20, 30, 50
Hydrogen Peroxide HR
2984
0-90
Pool
25
0, 15, 30, 50, 90
Hydrogen Peroxide
2984LR
0-50
Drinking, Food/Beverage
25/50
0, 1, 3, 10, 30, 30, 50
Phosphate, Low Range
3021
0-2500 ppb
Pool
25/50
0, 100, 200, 300, 500, 1000, 2500
ppb
Phosphate, High Range
3040-H
300012000 ppb
Pool
50
Sodium Chloride
2998
1500-5000
Pool
10, 50
3000, 6000, 12000 ppb
1500, 2000, 2500, 3000, 3500,
4000, 5000
* Kit includes a pre-treatment reagent.
34
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Insta-TEST® Test Strips
Accurate and Reliable
ACCURATE & RELIABLE Easiest test strips to read.
CONNECTED CAP Can’t fall into the water or be lost.
HINGE GUARANTEE Rated for 1000+ openings.
LEAKPROOF Airtight seal meets USDA and FDA requirements.
DESICCANT WALL Can’t fall onto wet hands.
6 GRAMS (NOT 3) Desiccant liner is double the industry standard for moisture protection.
DOUBLE DUTY High-density outer shell, combined with desiccant liner, ensure less moisture and light.
HDPP PROTECTION High density polypropylene plastic protects better than common HDPE bottles.
Multi-Factor Test Strips
Test Factor
Code
Copper, pH, & Alkalinity
3001-G
Range
0-3 (Copper)
6.2-8.4 (pH)
0-240 (Alkalinity)
Water Testing
Application*
# of Tests
Per Factor/
Per Vial
Values (ppm)
Pool
25
25
25
0, 0.3, 0.6, 1, 3
6.2, 6.8, 7.2, 7.6, 8.0, 8.4
0, 40, 80, 120, 180, 240
Iron & Copper
2994
0-5 (Iron)
0-3 (Copper)
Drinking, Pool
25
25
0, 0.3, 0.5, 1, 3, 5
0, 0.3, 0.6, 1, 3
Iron, pH, & Hardness
2980
0-5 (Iron)
4-10 (pH)
0-400 (Hard)
Drinking
25
25
25
0, 0.3, 0.5, 1, 3, 5
4, 5, 6, 7, 8, 9, 10,
0, 50, 100, 200, 400
Wide Range
(pH & Total Chlorine)
2987
4-10 (pH)
0-50 (TCl)
Drinking, Pool,
Food/Beverage
25, 50
25, 50
Nitrate & Nitrite
2996
0-50 (Nitrate)
0-10 (Nitrite)
Drinking
50
50
4, 5, 6, 7, 8, 9, 10
0, 1, 5, 10, 20, 50
0, 5, 10, 25, 50 (NO3-N)
0, 0.5, 1, 5, 10 (NO2-N)
*Strips shown have been evaluated for use in these applications. Use in other applications is subject to potential interferences.
Contact LaMotte Technical Services for more information.
Sanitizer Test Papers
Chemically treated paper strips change to indicate sanitizer level.
Strips and color chart are packaged in a waterproof plastic vial.
2951 is specifically formulated to read all types of QAC.
Factor
Chlorine
Chlorine, Free,
High Range
Iodine
Order Code
4250-BJ
3031
2948-BJ
Range
10, 50, 100, 200 ppm
(200 papers)
0, 50, 100, 250, 500, 800 ppm
(50 strips)
12, 25, 50, 100 ppm
(200 papers)
QAC
2951
50, 100, 200, 400 ppm
(100 strips)
QAC
3072-J
0, 100, 200, 300, 400, 500 ppm
(100 strips)
High Range
QAC
2951HR
200, 400, 600, 1000, 1500 ppm
(50 strips)
For PERACETIC ACID Test Strips, see page 34.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
35
Microbiological Testing
Micro Testing Simplified!
BioPaddles™
ƒƒ Ready to use. Saves time!
ƒƒ Longer shelf-life than traditional Petri dishes
ƒƒ No refrigeration required
ƒƒ Simple incubation requirements
BioPaddles™ are flexible dual-agar paddles each containing microbe-specific media enclosed in a
sterile vial. Identify and quantify microbes in air, soil, water, or any surface! BioPaddles do not require
any other testing equipment – only a magnifier and warm place (35°C or incubator) are needed.
Liquid Sampling: Remove the paddle from the vial and fill the vial (approximately 40ml) with the
sample. Insert the paddle, swirl for 15 seconds. Pour out the liquid, replace the paddle in the vial,
and incubate.
Surface Sampling: Remove the paddle from the vial and gently touch each paddle media surface
to the sample surface twice per side. Replace paddle in the vial and incubate.
Air Sampling: Remove the paddle from the vial. Invert and mount the circular cap into the vial, exposing the agar covered paddle. Expose for 15 minutes. Replace the paddle in the vial and incubate.
All BioPaddles™ products come with a free
app! LaMotte BioPaddles Colony ID™ App lets
users compare colony examples on BioPaddle
agar types from 5 microhabitats (air, water, soil,
surface and food). Also contains information regarding organisms, microbiological techniques,
and more!
BioPaddles™ Products – all packaged 10 paddles per box. Includes general instructions and
provides access to detailed Technical Documents for each paddle type.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1, r1) Small Qty. Hazardous Material - No Fees • (Lq, LQ, R2, r2, R3, r3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
36
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Microbiological Testing
Bacteria & Coliform Testing Kit
Type Of Agar(s)
Description
Code
R2A/MacConkey
For the cultivation and enumeration of bacteria from potable water, total coliform testing (TCC).
R2A selects for slow growing bacteria in stressed and chlorine treated water in potable water post-treatment
conditions. Tests for E. coli, Staphylococcus aureus, Pseudomonas aeruginosa, and B. cereus.
MAC is for the detection and enumeration of coliform organisms. Medium gives improved differentiation between
coliforms and non-lactose fermenting organisms. Gram (+) cocci are usually inhibited.
5540
NUT-TTC/EMB
For the cultivation and enumeration of Coliform bacteria including TCC (Total Colony Counts). Non-selective,
supports growth of a wide variety of organisms.
TTC for the cultivation and enumeration of coliform bacteria. Non-selective, supports the growth of a wide variety of
organisms. Aerobic bacteria reduce 2,4,5 - triphenyltetrazolium chloride dye to a red colored formazan dye. Gram (-)
bacterial colonies appear as red dots. Gram (+) bacteria are generally inhibited.
EMB (Eosin-Methylene Blue) is slightly selective for Gram (-) enteric microorganisms and inhibitive to Gram (+)
bacteria. Differentiates coliforms. E. coli grows metallic green, Salmonella and Shigella grow amber to colorless, and
other coliforms are blue-black.
5541
LIS/EMB
For enumeration and selective isolation of Listeria spp. and total coliform (TCC)
LIS for selective isolation of Listeria spp. Selectivity is increased by adding various antimicrobial agents to inhibit
most Gram (+) and (-) organisms after 24 hours of incubation.
EMB (Eosin-Methylene Blue) is slightly selective for Gram (-) enteric microorganisms and inhibitive to Gram (+)
bacteria. Differentiates coliforms. E. coli grows metallic green, Salmonella and Shigella grow amber to colorless, and
other coliforms are blue-black.
5542
HEK/SS
For enumeration and selective isolation of pathogenic intestinal bacteria.
HEK isolates and differentiates Salmonella spp. Inhibits Gram (+) organisms. Salmonella colonies appear black and
Shigella produces translucent green colonies.
SS isolates Salmonella spp. and some strains of Shigella spp. Inhibits Gram (+) bacteria, most coliform bacteria and
swarming Proteus spp., while allowing Salmonella spp. to grow.
5543
MacConkey/EMB
Isolation and differentiation of Gram (-) cocci enteric bacilli, coliform, and recovery of stressed coliforms.
MAC is for the detection and enumeration of coliform organisms. Medium gives improved differentiation between
coliforms and non-lactose fermenting organisms. Gram (+) cocci are usually inhibited.
EMB (Eosin-Methylene Blue) is slightly selective for Gram (-) enteric microorganisms and inhibitive to Gram (+)
bacteria. Differentiates coliforms. E. coli grows metallic green, Salmonella and Shigella grow amber to colorless, and
other coliforms are blue-black.
5544
Nutrient
For routine culture of non-fastidious bacteria.
5550
Sabouraud
Dextrose
For selective cultivation of fungi (yeasts and molds)
5551
Tryptic Soy (TSA)/ For cultivation of a wide variety of microorganisms (TSA) and selective isolation of yeasts and molds (RB).
Rose Bengal (RB)
Nutrient TTC/
MacConkey
5552
TTC. For field sampling cultivation and enumeration of coliform bacteria total coliform count (TCC). Gram (-) bacterial 5553
colonies appear as red dots. Gram (+) bacteria are usually inhibited.
MAC. Medium gives improved differentiation between coliforms and non-lactose fermenting organisms. Gram (+)
cocci are usually inhibited.
Coliform
The 4-3616 is an easy-to-use, disposable 5-tube method to indicate the presence
of Total Coliform Bacteria in a water supply. The water sample is placed in test vials
containing the special coliform indicating tablets and stored at room temperature for
a predetermined time period. After the required storage period, the vials are examined
to determine the presence of coliform bacteria. The test method and results closely
parallel the standard Total Coliform Multiple-Tube Presumptive Test (MPN) as outlined
in Standard Methods for the Examination of Water and Wastewater.
Code
Test System
Range/
Sensitivity
# of Tests
(# of Reagents)
Shipping Code
(Wgt./lbs)
4-3616
Tableted nutrient
based on 5 tube MPN
Presence/
Absence
1 (1)
NH (1)
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
37
Microbiological Testing
Biological Activity Reaction Test
A simple yet effective method for
monitoring the population size and/or
activity of specific groups of bacteria.
BART Biodetector
Easy to Use
With BART, you can monitor for Iron Related Bacteria (IRB), Sulfate Reducing Bacteria (SRB) and
Heterotrophic Aerobic Bacteria (HAB) – the three
most important agents involved in biofouling. Other
BART systems are described below. These bacteria
can cause corrosion, clogging, fouling of the water,
and increased hygiene risks, so it is important to
have an easy and accurate method of determining
their presence and level of activity.
The BART Biodetector requires no microscope, no laboratory, and
no incubator! The test is done at room temperature in your office
or treatment room, on a desk, shelf, or in a cupboard, and is viewed
daily. Different microorganisms like to grow at different heights
in a column of water to which nutrients have been added. BART
biodetectors contain nutrients in the base of a column and a ball.
The ball restricts the amount of oxygen entering the water column,
so that aerobic organisms grow around the ball and anaerobic
organisms grow deep down in the water column. By changing
the nutrients in the base of the column, different organisms are
encouraged to grow. BART determines presence and activity levels.
The screw-cap should
be tightened on the
BART tube so that
casual leakage, such
as from tipping the
tube over, can be
prevented.
Easy to Analyze
The time taken for a color change (reaction) to occur gives a measure of the population size and activity. A color change occurs in the BART tube as a result of the oxygen gradient diffusing from the bottom upward. The change of color indicates a
presence of bacteria within that sample. Interpretation is provided with the kit.
The Test
Full instructions for the use of BART biodetectors are included with your purchase. Each
individual test consists of:
Aerobic growth of
bacteria will occur at
the surface of the
sample between the
BART-BALL and the wall
of the BART tube.
15 mL of water sample is
used to bring the BARTBALL up to the correct
level. Nutrients will
gradually diffuse up the
water column to support
this bacteria growth.
Once the oxygen has
been used by the
aerobes, this zone
becomes free of oxygen
and anaerobic growth
will dominate.
Nutrient medium for
growth is provided as a
sterile dried pellet on the
floor of the tube.
38
ƒƒ Test vial with media and BART ball
ƒƒ Outer tube for spill containment, odor control, disinfection, and disposal
To Order
Each kit number below includes nine (9) BARTs, except the 5-0031 which contains seven
(7) BARTs and reaction caps. Each BART test is color-coded for quick and easy recognition.
BART Color
Test
Order
Red
Black
Iron Related Bacteria - IRB-BART
Sulfate Reducing Bacteria - SRB-BART
5-0024
5-0025
Lime green
Combo
Blue
Slime Forming Bacteria - SLYM-BART*
Three each of IRB-, SRB-, and SLYM-BART
Heterotrophic Aerobic Bacteria - HAB-BART
5-0026
5-0032
5-0027
*The SLYM-BART requires the use of a fluorescent lamp (Order Code 5-0033)
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Acidity - Aluminum
In cleaning
applications,
P alkalinity is
sometimes
referred to as
active alkalinity.
The difference
between the
P reading and
the T reading
is “inactive”
alkalinity.
Code 3569-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
ACIDITY A standard base titrates acidity to the phenolphthalein endpoint. The 7182 uses different sample sizes and a 1:10 dilution to test
hydrochloric, sulfuric and phosphoric acids with either a 1 drop = 0.1% or 1 drop = 1.0 % equivalence.
7182-01
HCl, H2SO4, H3PO4
Dropper Bottle
1 drop = 0.1 or 1.0%
(as the particular acid)
50 at 10% (2)
R1 (1)
ALKALINITY Kits use titrations with standard acid to the phenolphthalein(P) and/or total(T) alkalinity endpoint. The mixed indicator, BCG-MR, is
used for total alkalinity determinations. Where hydroxyl(OH) alkalinity is determined directly, as with kit #7515, the sample is pre-treated with
barium to precipitate carbonate alkalinity. All results are expressed as CaCO3. To convert results to Na2O, multiply the answer by 0.62.
4491-DR-01
Total Alkalinity
Direct Reading Titrator
0–200 ppm/4ppm as CaCO3CaCO3
50 at 200 ppm (2)
NH (1)
4533-DR-01
P & T Alkalinity
Direct Reading Titrator
0–200 ppm/4 ppm as CaCO3
50 at 200 ppm (3)
NH (1)
4533
P & T Alkalinity
Dropper Pipet
1 drop = 10 ppm as CaCO3
50 at 200 ppm (3)
NH (1)
7240-02
P & T Alkalinity
Dropper Bottle
1 drop = 10, 25, or 50 ppm as CaCO3
100 at 500 ppm (3)
R1 (2)
3467-01*†
P & T Alkalinity
Direct Reading Titrator
0–200 ppm/4 ppm as CaCO3
50 at 200 ppm (3)
R1 (1)
7515-01
P, T, & OH Alkalinity
Dropper Pipet
1 drop = 10 ppm as CaCO3
50 at 200 ppm (4)
R1 (1)
50 (2)
NH (1)
ALUMINUM A pink to red color will form when aluminum reacts with Eriochrome Cyanine R at pH 6.
3569-01
Octa-Slide 2 Comparator
0, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.5 ppm Al3+
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
39
Individual Test Kits
Ammonia Nitrogen - Bromine
Code 3304-01
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
AMMONIA NITROGEN Two colorimetric methods are available. Nessler’s reagent reacts with ammonia to form a yellow to brown color; salicylate
reacts to form a blue color, which in combination with the yellow reagent color produces colors from yellow to blue. The salicylate method is
preferred for salt water analysis and does not contain mercury salts as does the Nessler method.
3304-01
Salicylate,
Octa-Slide 2 Comparator
0.0, 0.05, 0.1, 0.25, 0.5, 1.0, 2.0 ppm NH3–N
50 (3)
R2 (1)
5864-01
Salicylate
ColoRuler
0.1, 0.25, 0.50, 1.0, 2.0, 4.0 ppm NH3–N
50 (2)
R1 (1)
3315
Nessler,
Octa-Slide 2 Comparator
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 ppm NH3–N
50 (2)
R1 (1)
3680-01
Nessler Colorimeter
0–5 ppm/0.05 ppm NH3–N
100 (2)
R1 (1)
ARSENIC The procedure requires about 15 minutes and employs a test strip. Inorganic As+3 and As+5 are converted to arsine gas. This reacts
with the test strip in a closed container and produces yellow to brown colors on the strip. The strip color is compared to a color chart to determine
concentration in ppb.
4053-02
Test Strip
<4, 4, 8, 10, 12, 14, 16, 20, 25, 30, 50, 85, 100, 150, 175,
200, 300, 400 ppb
50
R1 (8)
BACTERIA See Microbiological Testing section pages 36-38.
BIOCHEMICAL OXYGEN DEMAND (BOD) This is a determination of the amount of organic material in wastewater by measuring and comparing the
dissolved oxygen content before and after incubating the sample for 5 days at 20°C. All reagents, including seed capsules and glassware needed
to perform this test, are included in the kit. Incubator and DO meter are not included. See pages 84-85 for BOD accessories.
7420
Buret Titration
1 mL = 0.2 mg O2, 0–1000 mg/L
100 (10)
LQ (12)
BLEACH (See Chlorine Bleach)
BROMINE Bromine may be tested using color development with DPD, or by a ferrous ammonium sulfate titration in the presence of DPD
indicator. The 6824 kit uses glycine to enable the user to separate bromine and chlorine. The 3624 titration kit uses one sample size to test
chlorine and one to test bromine. It includes a 1:10 dilution for determination of concentrations of 100 ppm or higher.
40
6955-01
DPD Tablet,
Octa-Slide 2 Comparator
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br
50 (1)
NH (1)
6824-01
DPD Tablet, Bromine in
Chlorine,
Octa-Slide 2 Comparator
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br
50 (3)
NH (1)
3672-01
DPD Tablet, Colorimeter
0–7.0 ppm/0.05 ppm Br
100 (1)
NH (5)
3624-01
FAS Chlorine or Bromine,
Direct Reading Titrator
0–10 ppm/0.2 ppm Cl or Br
0-100 ppm/2 ppm Cl or Br
50 at 10 ppm
(3)
NH (1)
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Cadmium - Chloride
To measure sodium
chloride levels in pools see
test strips on page 34.
Code 7297-DR-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
Shipping Code
20 (4)
HF (1)
50 at 50 ppm (2)
R1 (1)
(# Reagents)
(Weight/Lbs)
CADMIUM A dithizone extraction of cadmium produces a pink to red color.
7839-02
Octa-Slide 2 Comparator
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd
CALCIUM (See Hardness)
CARBON DIOXIDE A standard alkali is used to titrate samples to the phenolphthalein endpoint.
7297-DR-01
Direct Reading Titrator
0–50 ppm/1.0 ppm CO2
CAUSTIC A sample is reacted with barium to precipitate any carbonates, then is titrated with a standard acid to the phenolphthalein endpoint.
The 7181 includes a 1:10 dilution, resulting in a 1 drop = 0.1% or 1 drop = 1% equivalence.
7516-DR-02
Direct Reading Titrator
0–10%/0.2% NaOH
50 at 10% (4)
R1 (1)
7181-01
Dropper Bottle
1 drop = 0.1 or 1% NaOH
50 at 10% (3)
R1 (1)
CHELANT Free chelant is determined by using the back titration of a hardness test, with magnesium as the titrant. Since bismuth will displace
other metals from chelants, it is used for total chelant determinations. Both tests use different sample sizes to determine NTA or EDTA.
7144-01
Free Chelant
Dropper Bottle
1 drop = 2 ppm EDTA
1 drop = 2 ppm NTA
100 (3)
R1 (1)
7143-01
Total Chelant
Dropper Bottle
1 drop = 5 ppm EDTA
1 drop = 5 ppm NTA
100 (3)
HF (1)
CHLORIDE The argentometric method is used with all kits. This employs a chromate indicator and silver nitrate titrant. Hydrogen peroxide is
included with kits 7172 and 7247 to eliminate sulfite interference.
Direct Reading Titrator
0–50 ppm/1 ppm Cl–
50 (2)
NH (1)
4503-DR-02
Direct Reading Titrator
0–200 ppm/4 ppm Cl–
0–20,000 ppm/400 ppm
50 at 200 ppm (4)
R1 (1)
7459-02
Salinity
Direct Reading Titrator
0-20 ppt/0.4 ppt Salinity
50 at 20 ppt (2)
R1 (1)
7172-02
Dropper Bottle
1 drop = 10, 25, or 50 ppm Cl–
120 at 100 ppm (5)
R1 (2)
7247-01
Dropper Bottle
1 drop = 2, 5, or 10 ppm Cl–
120 at 10 ppm (5)
R1 (1)
3468-01*†
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
41
Individual Test Kits
Chlorine - Chlorine
Code 3670-01
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
CHLORINE Free, Combined and Total Chlorine may be determined using DPD with either colorimetric or titrimetric methods. These
determinations are generally limited to concentrations of 0–10 ppm, although the FAS titration can test higher concentrations by dilution or with
the addition of more DPD indicator. Higher concentrations require the iodometric titration, whereby the sample is acidified and iodide is added,
which is oxidized by chlorine to iodine and is titrated with a standard thiosulfate solution. Iodometric determinations will only test total chlorine.
FREE & TOTAL
3308-01*
DPD Tablet
Octa-Slide 2 Comparator
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl
50 (2)
NH (1)
3312-01*
DPD Tablet
Octa-Slide 2 Comparator
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cl
50 (2)
NH (1)
3313-01*
DPD Tablet
Octa-Slide 2 Comparator
1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 ppm Cl
50 (2)
NH (1)
3314-01*
DPD Tablet
Octa-Slide 2 Comparator
Low: 0.1–1.0 ppm Cl
High: 1.0–6.0 ppm Cl
100 (2)
NH (1)
3328-01
DPD Tablet
Octa-Slide 2 Comparator
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm Cl
50 (2)
NH (1)
3670-01
DC1200-CL
DPD Tablet
Colorimeter
0–4.0 ppm/0.05 ppm Cl
100 (2)
NH (4)
3670-01-LI
DC1200-CL-LI
DPD Liquid
Colorimeter
0–4.0 ppm/0.05 ppm Cl
144 (3)
R1 (5)
50 (4)
NH (1)
200 (5)
NH (7)
DPD FREE CHLORINE, MONOCHLORAMINE, DICHLORAMINE, & TOTAL CHLORINE
3316-01
DPD Tablet
Octa-Slide 2 Comparator
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl
DPD FREE, MONO & DICHLORAMINES, TOTAL CHLORINE, pH
6980
DPD Tablet/
Phenol Red Tablet
Octa-Slide 2 Comparator
Low: 0.1–1.0 ppm Cl
High: 1.0–6.0 ppm Cl
pH: 6.8–8.2
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
42
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Chlorine - Chlorine Test Papers
Clean sample cells
used in DPD test
reactions as soon
as possible. DPD
can stain!
Code 4497-DR-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
Shipping Code
(# Reagents)
(Weight/Lbs)
CHLORINE ...Continued
DPD-FAS TITRATION FOR FREE AND TOTAL CHLORINE
3176-02*†
Direct Reading Titrator
0–10 ppm/0.2 ppm Cl
50 at 10 ppm (4)
R1 (2)
3624-01
Chlorine or Bromine
Direct Reading Titrator
0–10 ppm/0.2 ppm Cl or Br
0–100 ppm/2 ppm Cl or Br
50 at 10 ppm (3)
NH (1)
7514-01
FAS
Dropper Bottle Titration
1 drop = 0.2 or 0.5 ppm Cl
50 (3)
NH (1)
IODOMETRIC TITRATION (For higher total chlorine levels)
4497-DR-01
Direct Reading Titrator
0–200 ppm/4 ppm Cl
50 at 200 ppm (3)
R2 (1)
4497-01
Dropper Pipet
1 drop = 10 ppm Cl
50 at 200 ppm (3)
R2 (1)
4501-01
Dropper Pipet
1 drop = 1 ppm Cl
50 (3)
R2 (1)
50 at 10% (3)
R1 (2)
50 at 0.1, 1.0, or 10% (3)
R1 (1)
NH (1)
CHLORINE BLEACH, IODOMETRIC TITRATION
7105-03
Direct Reading Titrator
0–10%/0.2% Cl
7894-01
Dropper Pipet
1 drop = 0.005%, 0.05%, or 0.5% Cl
CHLORINE TEST PAPERS/STRIPS See other Chlorine test strips on page 34.
4250-BJ
Chlorine Test Papers
10, 50, 100, 200 ppm, Cl
200 (1)
2964-G
Chlorine Test Strips
0, 0.5, 1, 3, 5, 10 ppm, Free Cl
25 (1)
2963LR-G
Chlorine Test Strips
0, 0.1, 0.25, 0.5, 1, 3, 10 ppm, Total Cl
25 (1)
3031
Chlorine Test Strips
0, 50, 100, 250, 500, 800 ppm Cl
50 (1)
2979
Chlorine Test Strips
0, 0.5, 1, 3, 5 ppm Total Cl
50 (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
43
INDIVIDUAL TEST KITS
Chlorine Dioxide - Copper
Reagent Tip: Determine when your
reagent was made and bottled. The first 3
numbers of a lot number signify the week
and the year the reagent was made.
The last 3-4 numbers signify the month
and day of the month it was bottled.
Thus 501219 was made in the 50th
week of 2011 and bottled on Dec 19th.
Code 6616-01
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
CHLORINE DIOXIDE The colorimetric kits use DPD to determine chlorine dioxide. Glycine is added in the method to remove free chlorine
interferences. Chlorite up to 1,000 ppm and chlorine up to 2 ppm will not interfere with the test strip determinations.
3622-01
Octa-Slide 2 Comparator
0.0, 0.2, 0.6, 0.8, 1.0, 2.0, 3.0, 5.0 ppm ClO2 (0–10 by
dilution)
50 (2)
NH (1)
3671-01
DC1200-CLO
Colorimeter
0–7 ppm/0.05 ppm ClO2
100 (2)
NH (3)
2999LR
Test Strip
0, 0.25, 0.50, 1.0, 3.0, 10 ppm
50
NH (1)
3002
Test Strip
0, 10, 25, 50, 100, 250, 500 ppm
50
NH (1)
CHROMATE Diphenylcarbazide reacts with chromate (hexavalent chromium) to form a red to violet color in an acid solution.
4430-01
Diphenylcarbazide
Octa-Slide 2 Comparator
5, 10, 15, 20, 25, 30, 35, 40 ppm Na2CrO4
(lower or higher ranges by dilution)
50 (1)
R1 (1)
CHROMIUM Total, hexavalent and trivalent chromium are determined by this method. First, the hexavalent chromium is determined by reaction
with diphenylcarbazide, as above. A second sample is heated in the presence of an oxidizer, to determine total chromium. The difference between
total and hexavalent is trivalent. The heat source is not included.
7678-01
Octa-Slide 2 Comparator
0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5 ppm Cr
20 (5)
LQ (2)
COLIFORM See also Microbiological Testing section pages 36-38.
COLOR The color of water is measured by comparing the water to platinum cobalt color standards representing APHA Standard Color Units. See
also TC-3000, pages 8-9.
3528-01
LRC Comparator
0, 20, 50, 80, 110, 140, 170, 200 APHA color units
Unlimited (0)
NH (2)
COPPER A yellow color is formed when copper reacts with diethyldithiocarbamate (DDC). A blue color is formed when copper reacts with
cuprizone.
6616-01
LRC Comparator
0, 0.05, 0.10, 0.15, 0.20, 0.30, 0.40, 0.50 ppm Cu
50 (1)
NH (1)
3619
Cuprizone
Color Chart
0.05, 0.10, 0.15, 0.20, 0.30, 0.50, 0.70, 1.0 ppm Cu
50 (2)
R1 (1)
3673-01
DC1200-CO
DDC
Colorimeter
0–8 ppm/0.03 ppm Cu
100 (1)
NH (7)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
44
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
INDIVIDUAL TEST KITS
Cyanide - Glutaraldehyde
TWO CHOICES
FOR REFILLS:
1. For a complete set,
add “R-” to the kit
number.
2. For individual
reagents, order by the
code on the reagent.
See pages 76-83 for
a list of kit reagents.
Code 6701-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
CYANIDE The cyanide is first reacted with a chlorine donor to form cyanogen chloride, which then reacts with pyridine-barbituric acid to form a
red-blue color. The test is also applicable as a screening test for concentrations up to 250 ppm.
7387-02
Octa-Slide 2 Comparator
0.0, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40 ppm Free CN–
50 (5)
R1 (3)
DEHA Diethylhydroxylamine reacts with ferric iron to form ferrous iron, which is then measured by a standard iron test.
4790-01
Octa-Slide 2 Comparator
0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5 ppm DEHA
100 (3)
R1 (1)
DETERGENTS Anionic surfactants are extracted with toluene and break up an ion pair, releasing bromphenol blue into a water layer.
A standard color reagent is then used to determine the concentration.
4507-02
Dropper Pipet
1 drop = 1.0 ppm Detergent
60 at 5.0 ppm (3)
R1 (2)
4515-01
Dropper Pipet
1 drop = 0.1 ppm Detergent
30 (4)
LQ (2)
FLUORIDE A red zirconium lake reacts with fluoride to form a colorless solution, which decreases the red color of the solution in proportion to
concentration.
3674-01
DC1200-FL
Colorimeter
0–2.0 ppm/0.03 ppm Fl–
100 (2)
LQ (7+5)
FORMALDEHYDE The colorimetric analysis uses a modified Schiff reaction in which an acidified pararosaniline and dichlorosulfitomercurate II
complex form a violet color.
6701-01
Octa-Slide 2 Comparator
0.0, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm Formaldehyde
100 (3)
LQ (2+5)
GLUTARALDEHYDE High concentrations are determined by a titration with sulfuric acid after reaction with sulfite.
7064-01
Direct Reading Titrator
1 mL = 250 ppm Glutaraldehyde
25 (5)
R2 (3)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
45
Individual Test Kits
Hardness - Hydrazine
Hardness originally referred
to the ability of water to
lather with soap. The more
calcium and magnesium
ions present, the “harder” it
was to produce a lather.
Code 4482-LI-02
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
HARDNESS EDTA titration is used for all hardness determinations, with a red to blue endpoint. Both total and calcium hardness buffers include
inhibitors to eliminate metal interferences. All results are as CaCO3; some kits also express results as gpg. The 3609, which is recommended for
salt water analysis, includes a conversion factor for Ca++. The -LI suffix indicates an all liquid kit; -LT indicates a liquid buffer and tablet indicator.
3609-01
Fresh & Salt Water Calcium
Hardness
Direct Reading Titrator
0–200 ppm/4 ppm CaCO3
0-2,500 ppm by dilution
50 (3)
R1 (1)
4482-DR-LI-01
Total Hardness
Direct Reading Titrator
0–200 ppm/4ppm CaCO3
Liquid indicator
50 at 200 ppm (3)
R1 (1)
4482-LI-02
Total Hardness
Dropper Bottle
1 drop = 10 ppm or 1 gpg CaCO3
Liquid indicator
50 at 200 ppm
or 20 gpg (3)
R1 (1)
4482-DR-LT-01
Total Hardness
Direct Reading Titrator
0–200 ppm/4 ppm CaCO3
Tablet indicator
50 at 200 ppm (3)
R1 (1)
4824-LT-02
Calcium, Magnesium, Total
Hardness
Dropper Bottle
1 drop = 10 ppm or 1 gpg CaCO3
Tablet indicator
50 at 200 ppm
or 20 gpg (5)
R1 (1)
4824-DR-LT-01
Calcium, Magnesium, Total
Hardness
Direct Reading Titrator
0–200 ppm/4 ppm CaCO3
Tablet indicator
50 at 200 ppm (5)
R1 (1)
3037-DR-01
Low Range Total Hardness
Direct Reading Titrator
0–10 ppm/0.2 ppm CaCO3
50 at 10 ppm (3)
R1 (1)
7171-02
Total Hardness
Dropper Bottle
1 drop = 10, 25, or 50 ppm CaCO3
100 (3)
R1 (1)
7246-02
Total Hardness
Dropper Bottle
1 drop = 2, 5, or 10 ppm CaCO3
100 (3)
R1 (1)
50 (2)
R2 (1)
HYDRAZINE A yellow color is formed in the reaction of hydrazine and paradimethylaminobenzaldehyde.
4850
Octa-Slide 2 Comparator
0.00, 0.01, 0.05, 0.10, 0.20, 0.30, 0.40,
0.50 ppm N2H4
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
46
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Hydrogen Peroxide - Lead
Code 3347-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
HYDROGEN PEROXIDE Although peroxide may be tested colorimetrically with DPD, the most common method is iodometric titration using a
standard thiosulfate solution. Both methods are offered.
3188
DPD Tablet
Octa-Slide 2 Comparator
Low: 0.1, 0.3, 0.5, 0.75, 1.0, 1.25, 1.5, 2.0 ppm H2O2
High: 2, 6, 10, 15, 20, 25, 30, 40 ppm H2O2
50 (2)
NH (1)
7138-DB-01
Iodometric
Dropper Bottle
1 drop = 5 ppm H2O2
50 (4)
LQ (2)
7150-01
Iodometric
Dropper Bottle
1 drop = 0.5% H2O2
50 (4)
LQ (2)
2984LR-H
Test Strips
0, 1, 3, 10, 30, 50
50 (1)
NH (1)
IODINE As with many other oxidizers, iodine may be titrated with a standard thiosulfate solution, hence the name iodometric titration.
7253-DR-01
Direct Reading Titrator
0–50 ppm/1 ppm I2
50 at 50 ppm (3)
R1 (1)
7253-01
Dropper Pipet
1 drop = 2.5 ppm I2
100 at 25 ppm (3)
R1 (1)
2948-BJ
Test Papers
12, 25, 50, 100 ppm I2
200
NH (1)
IRON Bipyridyl is a ferrous iron indicator that tests total iron after any ferric iron is reduced to ferrous in the sample. Ferrous and ferric may
be tested separately by eliminating the reduction step. A similar ferrous indicator, 1,10 phenanthroline, is used in the DC1200 kit.
7787-01
Total Iron
LRC Comparator
0.05, 0.10, 0.20, 0.30, 0.40, 0.60, 0.80, 1.0 ppm Fe
30 (2)
R1 (1)
3318
Total Iron
Octa-Slide
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe
90 (2)
R1 (1)
3347-01
Ferrous/Ferric Iron
Octa-Slide 2 Comparator
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe
100 (2)
R1 (1)
3681-01
DC1200-FE
Total Iron
1, 10 Phenanthroline
Colorimeter
0–4.0 ppm/0.25 ppm Fe
100 (2)
R1 (1)
LEAD The presence of lead in solder is detected by the reaction of a solder sample with acid and sodium rhodizonate.
3582
Spot Plate
Plumbing Inspector Kit
Yes/No
100 (3)
R1 (2)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
47
Individual Test Kits
Manganese - Nickel
Molybdenum x 1.6 = Molybdate
Sodium Molybdate Dihydrate x 0.4 = Molybdenum
Molybdate x 0.63 = Molybdenum
Order Code
Test System
(Detailed On Pages 6-7)
Code 6628-01
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
MANGANESE The 1-(2-pyridylazo)-2-naphthol(PAN) method forms an orange complex with manganese. Metal interferences with the PAN
method can be eliminated using the #7104 Cyanide Inhibitor Package, sold separately.
3588-02
PAN
Octa-Slide 2 Comparator
0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0 ppm Mn
50 (4)
LQ (2)
3682-01
DC1200-MN
PAN
Colorimeter
0–0.7 ppm/0.01 ppm Mn
100 (3)
R3 (7+5)
METHYLENE BIS THIOCYANATE MBT is used as a microbiocide in water systems and wood treatment products. The method uses a titration of
excess silver ions after their reaction with the thiocyanate.
7148-01
Dropper Bottle
0-30 ppm/2 ppm MBT
50 at 25 ppm(5)
R1 (1)
MICROBIOLOGICAL TESTING See section pages 36-38.
MOLYBDATE/MOLYBDENUM There are three colorimetric methods and one titration method available. The 6628 uses Xanthogonate to form a
pink color with molybdate. Thioglycolate forms a yellow color for low to high determinations. The 3628 uses a new test strip technology that
reads 0, 0.5, 1, 2 and 5 ppm. Results are available in about 1 minute. The 3632 titration employs citric acid with a red to yellow color change. The
sample size may be changed to vary the equivalence.
3628-01
Test Strip
0, 0.5, 1.0, 2.0, 5.0 ppm
50 (1)
R1 (1)
6628-01
Xanthate, Sodium Molybdate
Octa-Slide 2 Comparator
1, 2, 3, 4, 5, 6, 8, 10 ppm Sodium Molybdate
100 (2)
R1 (1)
3346-01
Thioglycolate, Molybdate
Octa-Slide 2 Comparator
30, 60, 90, 120, 150, 180, 240, 300 ppm
Molybdate
50 (2)
NH (1)
3160
Thioglycolate, Molybdenum
Octa-Slide 2 Comparator
2, 5, 8, 10, 12, 15, 18, 20 ppm Molybdenum
50 (3)
R3 (2)
3632-01
Molybdenum
Dropper Pipet
1 drop = 2 or 20 ppm Molybdenum
50 (3)
LQ (2+5)
3676-01
DC1200-MO
Thioglycolate
Colorimeter
0-30 ppm/0.1 ppm Molybdenum
50 (3)
R3 (7)
20 (7)
LQ (9)
NICKEL Under acidic conditions, nickel reacts with dimethylglyoxime to form an orange-red complex.
7802
Octa-Slide 2 Comparator
0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 7.5, 10.0 ppm Ni
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
48
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Nitrate Nitrogen - Nitrite, Sodium
The current EPA limit
for nitrate is 10 ppm
as nitrogen. Multiply
nitrogen readings by
4.4 to convert reading
to nitrate.
Code 3354-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
NITRATE NITROGEN The nitrate is reduced to nitrite by cadmium or zinc and this undergoes diazotization/coupling to form a pinkish color. All kits
below use cadmium except #3354, which uses zinc and which also contains a reagent that eliminates nitrite interference. Kit #3519 tests both
nitrate and nitrite. The kit #3119 uses one comparator that contains both nitrate and phosphate standards. The phosphate method in kit #3119
is an ascorbic acid reduction. See page 16 for Total Nitrogen Digestion Tube Test.
3319-01
Cadmium Reduction
Octa-Slide 2 Comparator
0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3––N
3119-01
Cadmium Reduction
Nitrate/Phosphate
LRC Comparator
0.2, 0.4, 0.6, 1.0 ppm NO3––N;
0.2, 0.4, 0.6, 1.0 ppm PO43–
3615-01
Cadmium Reduction
LRC Comparator
3519-01
40 (2)
R1 (2)
Nitrate: 40 (2)
Phosphate: 50 (2)
R1 (2)
0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3––N
50 (2)
R1 (2)
Cadmium Reduction
Octa-Slide 2 Comparator
0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3––N
40 (3)
R1 (1)
3354-01
Zinc Reduction
Octa-Slide 2 Comparator
0.0, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0, 15.0 ppm NO3––N
50 (2)
NH (2)
3677-01
DC1200-NA
Cadmium Reduction
Colorimeter
0–3.0 ppm/0.05 ppm NO3––N
50 (2)
R1 (7)
NITRITE NITROGEN As with nitrate, above, the diazotization/coupling reaction is used to form a pink color with nitrite.
3352-01
Octa-Slide 2 Comparator
0.05, 0.10, 0.20, 0.30, 0.40, 0.50, 0.60, 0.80 ppm
NO2––N
50 (3)
NH (2)
NITRITE, SODIUM Sodium nitrite is titrated using one of two methods. After acidifying the sample, permanganate will oxidize nitrite. When all of
the nitrite is oxidized, the permanganate turns the sample pink. Ceric Ammonium Nitrate (CAN) also oxidizes the nitrite in the presence of ferroin
indicator. The endpoint is orange to blue. The CAN method is preferred if glycol is present.
7101-DR-01
Permanganate
Direct Reading Titrator
0–1000 ppm/20 ppm NaNO2
7101-01
Permanganate
Dropper Pipet
1 drop = 50 or 100 ppm NaNO2
3036-DR-02
CAN
Direct Reading Titrator
7183-02
CAN
Dropper Bottle
50 at 1000 ppm (2)
R1 (1)
50 at 1000 or
2000 ppm (2)
R1 (1)
0–1000 ppm/20 ppm NaNO2
50 at 1000 ppm (2)
R1 (1)
1 drop = 50 ppm NaNO2
50 at 1000 ppm (2)
R1 (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
49
Individual Test Kits
Oxygen, Dissolved - Phenols
It is important in all drop titrations to hold the
titrant vertically. This ensures proper drop size.
Code 5860-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
OXYGEN, DISSOLVED The azide modification of the Winkler method is a modified iodometric titration whereby oxygen, in the presence of a strong
alkali, oxidizes manganese, which in turn reacts with iodide to form iodine. This is titrated with a standard thiosulfate solution in the presence of a
starch indicator to enhance the endpoint. Azide eliminates nitrite interference.
5860-01
All liquid reagents
Direct Reading Titrator
0–10 ppm/0.2 ppm O2
50 at
10 ppm (5)
R1 (2)
OZONE DPD reacts with ozone, but any other oxidizers will interfere. The Indigo Trisulfonate method includes a step to eliminate chlorine
interference, but bromine will interfere. It is preferred for the analysis of salt water samples.
3526
DPD Tablet
LRC Comparator
0.01, 0.03, 0.07, 0.11, 0.2, 0.4, 0.7,
1.0 ppm O3
50 (2)
NH (1)
3678-01
DC1200-OZ
Indigo Trisulfonate
Colorimeter
0–0.4 ppm/0.04 ppm O3
100 (3)
NH (7)
PERACETIC ACID/HYDROGEN PEROXIDE This test is a combination of two separate titrations. The first is a cerium titration of peroxide. The
second is an iodometric titration of peracetic acid.
7191-02
Dropper Bottle
1 drop = 50 ppm Peroxide
1 drop = 15 ppm Peracetic Acid
50 (5)
R1 (2)
PERACETIC ACID TEST STRIP
3000
Test Strips
0, 10, 20, 40, 60, 85, 160 ppm
50
NH (1)
3000LR
Test Strips
0, 5, 10, 20, 30, 50 ppm
50
NH (1)
3000HR
Test Strips
0, 50, 100, 250, 500, 1000
50
NH (1)
pH TEST PAPERS
2907
Test Papers
6.8-8.4 pH/0.4 pH
1 Roll
NH (1)
2912
Test Papers
3.0-10.0 pH/1 pH
200 Strips
NH (1)
2953
Test Papers
4.5-7.5 pH/0.5 pH
1 Roll
NH (1)
2954
Test Papers
0-13 pH/1 pH
1 Roll
NH (1)
2955
Test Papers
9-14 pH/0.5 pH
1 Roll
NH (1)
2956
Test Papers
1-11 pH/1 pH
1 Roll
NH (1)
2959
Test Papers
8-12 pH/0.5 pH
2 Rolls
NH (1)
3-2950
pH Indicator Sticks
0–14/1 pH
100 Strips
NH (1)
PHENOLS 4-aminoantipyrine is oxidized in the presence of ortho and meta substituted phenols to form a reddish colored complex.
7824
LRC Comparator
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Phenol
50 (3)
N (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
50
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
pH
pH indicators work in a
specific range. Samples
with a pH above the range
of an indicator may match
the highest standard on the
comparator; samples below
the range may match the
lowest standard.
Code 5858-01
pH must be controlled and monitored because it plays an essential role in
almost all chemical and biological processes.
LaMotte pH Test Kits
The “Precision Wide Range” pH kit includes the Octa-Slide comparator and reagents to provide
100 tests. Other pH test kits consist of an Octa-Slide Comparator, and a reagent for 50 tests.
LaMotte Company has been supplying laboratory quality pH indicator tests to professional analysts for more than
eighty years; these are the most reliable, economical pH test kits available. Simply fill the tube to the mark with
the sample water, add several drops of indicator, and compare the resulting color against the eight permanent
color standards in the comparator.
How To Select The Right pH Kit:
Single or Wide Range?
Single range kits cover a range of 1.4 pH units in 0.2 unit increments (0.1 unit sensitivity). Wide range kits cover
pH units in increments of 0.5.
Which Range?
Choose a kit in which the midpoint of the range covered is as close to the average or optimum pH value of the
sample water. If this value is unknown, choose the Precision Wide Range Kit.
See Instrument
Section, pages 22-30
for pH meters.
Indicators specific to a particular pH range allow colorimetric determination of pH. If the water to be tested is
cloudy, one may wish to use a pH meter.
Order Code
pH
2109-01
2110-01
2111-01
2112-01
Octa-Slide Comparator Color
Standard Values In pH Units
pH Indicator
Bromthymol Blue
Phenol Red
Cresol Red
Thymol Blue
5858-01
Precision Wide Range
2124-01
3353-01
Alkaline Wide Range
Precision Wide Range
6.0
6.8
7.2
8.0
3.0
7.0
8.5
5.0
6.2
7.0
7.4
8.2
3.5
7.5
9.0
6.0
6.4
7.2
7.6
8.4
4.0
8.0
9.5
6.5
6.6
7.4
7.8
8.6
4.5
8.5
10.0
7.0
6.8
7.6
8.0
8.8
5.0
9.0
10.5
7.5
7.0
7.8
8.2
9.0
5.5
9.5
11.0
8.0
Hazard
(Shipping Weight/Lbs)
7.2
8.0
8.4
9.2
6.0
10.0
11.5
9.0
7.4
8.2
8.6
9.4
6.5
10.5
12.0
10.0
NH (1)
NH (1)
NH (1)
NH (1)
R1 (1)
R1 (1)
R1
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
51
Individual Test Kits
Phosphate - Phosphate
Code 3114-02
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
PHOSPHATE There are 3 colorimetric test methods. In two, a phosphomolybdate complex is reduced by stannous chloride or ascorbic acid to
produce a blue color. In a third, phosphate forms a yellow complex with vanadomolybdate.
3679-01
DC1200-PLR
Ascorbic Acid
Colorimeter
0–3.0 ppm/0.07 ppm PO43–
100 (2)
R2 (7)
3121-02
Ascorbic Acid
LRC Comparator
0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43–
50 (2)
R1 (1)
3114-02
Ascorbic Acid
Octa-Slide 2 Comparator
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm and 5.0, 10.0, 20.0,
30.0, 40.0, 60.0, 80.0, 100.0 ppm PO43–
50 (2)
R1 (1)
7416-02
Stannous Chloride
LRC Comparator
0.05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm PO43–
50 (2)
R1 (1)
3320-01
Stannous Chloride
Octa-Slide 2 Comparator
Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO43–
High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO43–
50 (2)
R1 (1)
4408-01
Stannous Chloride
Octa-Slide 2 Comparator
Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO43–
High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO43–
50 (2)
LQ (1)
7068-01
Stannous Chloride
Octa-Slide 2 Comparator
Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO43–
High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO43–
50 (2)
LQ (1)
4401-02
Vanadate Molybdate
Octa-Slide 2 Comparator
10, 20, 30, 40, 50, 60, 70, 80 ppm PO43–
50 (1)
R1 (1)
PHOSPHATE (TOTAL) Polyphosphates (acid-hydrolyzable or condensed) and phosphonates (organic phosphates) are reverted
using the reagents and apparatus in the 7884 Auxiliary Phosphate kit. The polyphosphates require boiling or microwaving with
acid and subsequent neutralization; the phosphonates require the same, but with the addition of an oxidizer in the boiling/
microwaving step. Once reverted to orthophosphate, any of the tests in the orthophosphate section above may be used for
analysis. See page 16 for Total Phosphorus Digestion Tube Tests.
HF (2)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
52
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Phosphonate - Potassium
Code 7625-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code
(Weight/Lbs)
PHOSPHONATE The Chromazurol S method may be used for Dequest, Bayhibit, Belcor 575 and Belsperse 161 phosphonates. The indicator
changes from yellow to pink at the pH ideal for the reaction, then thorium nitrate is added until the solution turns purple. The Xylenol Orange
method titrates all Dequest products and Belcor 575. The pH is adjusted to 2.5-3.0, then thorium nitrate is added until the color changes from
yellow to red.The 4068 uses a masked xylenol orange indicator, which produces a green to blue endpoint. It also employs a tablet to adjust the pH
to the required 2.5-3.0. An additional liquid acid is included for very high alkalinity samples. It also includes a fluoride inhibitor reagent.
The 7611 sulfate interference suppressor kit uses barium precipitation and filtration to eliminate sulfate from the phosphonate test.
7625-DR-01
CAS
Direct Reading Titrator
0–20 ppm/0.4 ppm HEDP/PBTC
50 at 20 ppm (5)
R1 (1)
7625-01
CAS
Dropper Pipet
1 drop = 1.25 ppm HEDP
1 drop = 1.4 ppm PBTC
50 at 20 ppm (5)
R1 (1)
7530-DR-01
XO
Direct Reading Titrator
0–20 ppm/0.4 ppm NaAMP
50 at 20 ppm (5)
R1 (2)
7530-WT-01
XO
Dropper Bottle
1 drop = 1 ppm NaAMP
50 at 20 ppm (5)
R1 (2)
4068-01
Masked XO
Direct Reading Titrator
0-20 ppm/0.4 ppm HEDP
50 at 20 ppm (4)
R1 (2)
POLYPHOSPHATES A colorimetric method is available for waters where metal interference is unlikely. An excess of iron is added to the solution
containing polyphosphate. The iron is complexed and the remaining iron is determined. The polyphosphate concentration is derived from the iron
concentration.
7340-R-01
LRC Comparator
0, 3, 6, 9, 12, 15 ppm Polyphosphate
50 (3)
R2 (1)
POLYQUAT The test is based on the reaction of the cationic polyquat with an anionic polyelectrolyte using Toluidine Blue O as the indicator. The
color change is blue to purple.
7056-01
Dropper Bottle
1 drop = 1 ppm Polyquat
100+ (5)
R1 (1)
POTASSIUM Sodium tetraphenylboron reacts with potassium to form a white precipitate. The turbidity of the solution is proportional to
potassium concentration which is measured in a calibrated tube.
3138-01
Turbidity Reading Tube
6, 8, 10, 20, 30, 40, 50 ppm K+
100 (2)
R1 (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
53
Individual Test Kits
QAC - Sulfate
Many wood treating
companies use QAC
kits to monitor their
products because the
wood preservatives
react similarly to QAC.
Code 3043-DR-01
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
QAC Two methods are available. A masked bromphenol blue indicator is added to the sample and turns green. Sodium tetraphenylboron is added to complex the QAC and the color changes to red. This method is best suited to higher QAC concentrations. A poly-electrolytic
titration, like the one used for polyquat, is used for low to high concentrations.
3043-DR-01
BPB
Direct Reading Titrator
0–500 ppm/10 ppm
Alkyl dimethyl benzyl ammonium chloride
50 at 500 ppm (2)
NH (1)
3042-01
BPB
Direct Reading Titrator
0-1,000 ppm/20 ppm
0-5,000 ppm/100 ppm with dilution
50 at 1,000 ppm (2)
NH (1)
7057-01
Polyelectrolytic
Dropper Bottle
1 drop = 2, 5, or 10 ppm
Alkyl dimethyl benzyl ammonium chloride
100+ (5)
R1 (2)
2951
Test Papers
50, 100, 200, 400 ppm
100
NH (1)
2951HR
Test Strips
50, 100, 200, 400 ppm
100
NH (1)
SALINITY Salinity is based on the concentration of chloride. An argentometric titration with silver nitrate is used to determine the chloride
concentration.
7459-02
Direct Reading Titrator
0–40 ppt/0.4 ppt Salinity
50 at 20 ppt (2)
R1 (1)
SILICA The heteropoly blue method tests for “molybdate-reactive” silica. The 4463 uses a 1:10 dilution to expand the range of the kit to 100
ppm.
4463-01
Octa-Slide 2 Comparator
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm or
5, 10, 20, 30, 40, 60, 80, 100 ppm SiO2
50 (4)
R1 (1)
3321
Octa-Slide 2 Comparator
0.5, 1,0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm SiO2
50 (4)
R1 (1)
SODIUM NITRITE (See Nitrite, Sodium)
SULFATE Barium forms a precipitate with sulfate. The turbidity formed is measured using comparator standards or a meter.
7778-01
Tablet
Octa-Slide 2 Comparator
20, 40, 60, 80, 100, 120, 160, 200 ppm SO42–
50 (1)
R1 (1)
3683-01
Colorimeter
0–100 ppm/1.0 ppm SO42–
100 (1)
R1 (6)
The 7611 sulfate interference suppressor kit uses barium precipitation and filtration to eliminate sulfate from the phosphonate test.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
54
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Individual Test Kits
Sulfide - Zinc
Code 7391-02
Order Code
Test System
(Detailed On Pages 6-7)
# of Tests
(# Reagents)
Range/Sensitivity
Shipping Code
(Weight/Lbs)
SULFIDE Both kits use the Pomeroy methylene blue method for analysis. The colorimetric method uses color standards to read total sulfide.
Total, dissolved and hydrogen sulfide can be separated in the titration test. The total sulfide is determined using a color dye which is added to
an unreacted sample until it matches a reacted sample. The same procedure is used for dissolved sulfide, after insoluble matter is removed by
aluminum floc. Hydrogen sulfide is determined by measuring pH and multiplying the dissolved sulfide concentration by a pH correction factor.
50 (3)
R1 (1)
3322-01†
Total Sulfide
0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0, 20.0 ppm S2–
Octa-Slide 2 Comparator
4456-01
Total Sulfide
0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0, 20.0 ppm S2–
50 (3)
R1 (1)
Octa-Slide 2 Comparator
4630†*
Total, Dissolved &
1 drop = 1.0 or 0.1 ppm S2– or H2S
70 at 10 ppm (8)
LQ (10)
Hydrogen Sulfide
Dropper Pipet
SULFITE An iodide-iodate titrant oxidizes sulfite to sulfate under acid conditions, until all of the sulfite is reacted. The titrant then reacts with
starch to form a blue color signifying the endpoint.
7175-DR-01
7175-01
7132-01
Direct Reading Titrator
Dropper Pipet
Dropper Bottle
0–100 ppm/2 ppm SO32–
1 drop = 5 ppm
SO32–
1 drop = 2, 5, or 10 ppm
SO32–
50 at 100 ppm (3)
R1 (1)
50 at 100 ppm (3)
R1 (1)
100+ (3)
R1 (1)
TANNIN/LIGNIN Tungstophosphoric and molybdophosphoric acids are reduced by tannins and lignins to form a blue color.
7831-01
Octa-Slide 2 Comparator
1, 2, 3, 4, 5, 6, 8, 10 ppm Tannin or lignin like
substances
50 (2)
R1 (1)
TOLCIDE PS BIOCIDE This kit was developed in cooperation with Rhodia, formerly Albright & Wilson, for the determination of tetrakishydroxymethyl phosphonium sulfate (THPS). The iodometric titration may be used for fresh or salt water in oilfields, towers, pulp and paper, etc.
4-8776
Direct Reading Titrator
0-100/2 ppm THPS
60 (5)
NH (1)
ZINC In a solution buffered to pH 9, zincon reacts with zinc to form a blue color.
7391-02
Octa-Slide 2 Comparator
0, 1, 2, 3, 4, 6, 8, 10 ppm Zn
50 (2)
NH (1)
7417-02
Octa-Slide 2 Comparator
0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4 ppm Zn
50 (2)
NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
55
Aquaculture & Aquarium Waters
Fish Farms, Hatcheries, Research, Hobbyists, Retailers, Ornamental Fish Culturists...
Fresh Water Outfit
Model AQ-2, Order Code 3633-04 (Ship Code R3; 16 lbs.)
Reagent Refill, Order Code R-3633-03 (Ship Code R3)
A complete outfit for pond fish culture, ideal for fresh water analysis. Nine critical test
factors can be determined on-site, efficiently and accurately. Designed with field analysis
as a priority; all reagents, components, and accessories are arranged in pre-drilled foam.
Short form instructions are provided in a handy adhesive lid label for easy access. Long
form instruction booklet provides detailed instructions and test kit diagram. Unit is supplied complete with labware, accessories, sampling bottle, and reagents.
Factor
Method
Ammonia Nitrogen
Nitrite Nitrogen
Nessler
Diazotization/
Coupling
Wide Range
pH
Range
(# of Tests)
Factor
Method
Range (# Tests)
Alkalinity, Total
Carbon Dioxide
Chloride
Dissolved Oxygen
Neutralization
Neutralization
Argentometric
Azide Modification
of Winkler Method
Complexometric
0–200 ppm (50)
0–50 ppm (50)
0–200 ppm (50)
0–10 ppm (50)
Hardness (Total)
0.2–3.0 (50)
0.05–0.8 (50)
0–200 ppm (50)
Temperature
Armored Thermometer
5.0–10.0 (50)
–5° to 45°C
Salt Water Outfit
Model AQ-4, Order Code 3635-04 (Ship Code R2; 16 lbs.)
Reagent Refill, Order Code R-3635-03 (Ship Code R2)
Provides equipment to monitor nine parameters most critical for the salt water aquaculturalist.
Reagents, labware, and accessories are mounted in foam for convenient test selection and portability. Short form lid label instructions are always available for quick reference, and a long form
booklet provides detailed instructions with kit diagram. Unit is supplied complete with labware,
accessories, sampling bottles, and reagents.
Factor
Method
Alkalinity*
Carbon Dioxide
Neutralization
Neutralization
0–200 ppm (50)
0–50 ppm (50)
Dissolved Oxygen
Azide Modification
of Winkler Method
Argentometric
0–10 ppm (50)
Salinity
Range (# of Tests)
0–20 ppt (50)
*Often referred to as carbonate hardness in aquarium industry.
Factor
Range
Armored
Thermometer
–5° to 45°C
Factor
Method
Ammonia Nitrogen
Nitrate Nitrogen
Nitrite Nitrogen
pH
Salicylate
Cadmium Reduction
Diazotization/Coupling
Wide Range
Range (# of Tests)
0.05–2.0 ppm (50)
0.25–10.0 pm (40)
0.05–0.8 ppm (50)
5.0–10.0 (50)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
56
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Environmental Studies
Elementary, Secondary, Vocational, Outdoor, & College Science
Water Quality Educator
Monitoring Outfit
Order Code 5870-01 (Ship Code R1; 14 lbs.)
Always the first kit recommended for beginning a
water quality monitoring study. The Water Quality
Educator and Monitoring Outfit provides kits for
seven basic water quality test factors and exceptional support material, all housed in a rugged field
carrying case.
The Monitor’s Handbook, a 71-page reference guide,
includes all the information needed to set up a water
quality monitoring program. The handbook covers
test procedures and means to interpret results.
The Water Quality Educator CD-ROM, now for PC
and Macintosh computers, incorporates Quick
TimeTM animations, still photos, written and audio
information to provide step-by-step instructions
for the tests included. Students receive both visual
and verbal instructions and can repeat material as
often as necessary. This effective “pre-lab” activity
helps prepare students for water quality testing in
the field or in the classroom.
The CD also provides benchmark data for each
test factor for comparison of results obtained using LaMotte test kits in the field. Students enter
their results and receive information on what type
of water quality is indicated by their data as well as
typical causes and effects of higher and lower levels.
Factor
Range (# Tests)
pH
Nitrate-Nitrogen
Phosphate
Dissolved Oxygen
Alkalinity, Total
Turbidity
Temperature
pH 3.0–10.5 (100)
0–15 ppm (50)
0–2.0 ppm (50)
0–10.0 ppm (50)
0-200 ppm (50)
0-200 JTU (50)
–5° to 45°C
Leaf Pack Experiments Stream Ecology Kit
Order Code 5882 (Ship Code NH; 10 lbs.)
Students performing the Leaf Pack Experiments learn to
design, implement, and analyze a scientific investigation
by discovering how aquatic macroinvertebrates indicate
the overall health of a stream ecosystem. The Leaf Pack
Experiments Kit is totally reusable and flexible. Adaptable
to varying time constraints, number of students, and
grade levels, it is geographically friendly and complete.
All the apparatus and guides necessary for collecting,
sorting and identifying are included. The kit includes a
comprehensive Instructor’s Manual - featuring background material on stream ecology, a glossary, diagramed
instructions, experiment ideas, and full color macroinvertebrate flash cards. Developed by the Stroud Water
Research Center in cooperation with LaMotte Company.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
57
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
Plankton Net
Kick-Net
15” (38.1 cm) tall,
5” (12.7 cm) dia. mouth
Kick-Net, complete with poles
Order Code 1063; (2 lbs.)
Cone-shaped net of 10 mesh,
153 micron nylon cloth. Minute
plankton are collected and can
be observed in the removable,
clear conical graduated tube.
Two tubes provided. Net mouth
is braced by a sturdy stainless
steel ring and harness.
Order Code 0021-P (8 lbs.)
Kick-Net only Order Code 0021 (4 lbs.)
This 1x1 meter square, 500 micron, tan mesh net is
designed to meet the requirements of groups performing US EPA Rapid Bioassessment Protocols for benthic
invertebrates.
Secchi Disk
Disk with black & white quadrants & calibrated line
Order Code 0171-CL (3 lbs.)
Weighted 20 cm diameter disk has a braided stretch-resistant
line marked every half meter and at every meter up to 20 meters.
Limnology Outfit
Code 5902-02
(Ship Code R1; 13 lbs.)
Reagent Refill
Code R-5902-01
(Ship Code LQ; 4 lbs.)
A popular outfit for the testing and
study of freshwater systems such
as ponds, lakes, wetlands, rivers,
streams, etc. This field-friendly
outfit contains individual test modules, water sampling bottles, three
supplemental handbooks, and data
sheets.
Marine Science Outfit
Comparator Tests
Factor
Range (# Tests)
NitrateNitrogen
Phosphate
pH
Silica
0.2–1.0 ppm (40)
0.2–1.0 ppm (50)
3.0–10.0 pH (50)
0.5–10 ppm (50)
Direct Reading Titrator Tests
Factor
Range (# Tests)
Carbon
Dioxide
Dissolved
Oxygen
Hardness
0–50 ppm (50)
0–10 ppm (50)
0–200 ppm (50)
Code 5903-03
(Ship Code R1; 13 lbs.)
Reagent Refill
Code R-5903-02
(Ship Code R1; 4 lbs)
For testing and study of saline
systems – oceans, bays, salt
marshes, etc. Includes the Lab
Manual for Marine Science,
Investigating Water Problems
and data sheets.
Colorimetric Tests
Factor
Range (# Tests)
pH
pH
3–10 (50)
7.7–8.4 (50)
Titration Tests
Factor
Range (# Tests)
Dissolved
Oxygen
Hardness
Carbon
Dioxide
Alkalinity
Salinity
0–10.0 ppm (50)
0–200 ppm (50)
0–50 ppm (50)
0–200 ppm (50)
0–20 ppm (50)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
58
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Environmental Studies
Elementary, Secondary, Vocational, Outdoor, & College Science
The Tour Series
Each Tour is a complete, hands-on, science curriculum with safe, simple TesTabs® tablet tests. Each Tour includes lecture materials, illustrated handouts, teacher tips, test procedures, TesTab reagents, data sheets, and games to reinforce key concepts. The Tour Series is designed for grades 4 through
8 environmental science education. The Goal of the Tour series is for students to discover, examine, measure, and compare physical and chemical
properties. Students learn basic analytical methods while performing a scientific investigation.
Shore Tour
Shore Tour, Order Code 5939 (Ship Code NH; 5 lbs.)
Reagent Refill, Order Code R-5939 (Ship Code NH; 1 lb.)
Five units teach students through classroom lectures and activities how their everyday actions affect the
ocean. Topics include an introduction to coastal ecosystems, oil spills, shoreline development and marine
debris. Includes teacher tested activities from EPA, NOAA, and The Marine Mammal Center, links to activities
and information from ocean experts, CD with printable handouts, data sheets, and more. Materials for 40
students working in groups.
Watershed Tour
Watershed Tour, Order Code 5419 (Ship Code NH; 4 lbs.)
Reagent Refill, Order Code R-5419 (Ship Code NH; 1 lb.)
A classroom-based tour of a virtual watershed, designed for teachers who are unable to visit a stream with
their students. Students will “test” four stations along a river continuum to study how the river changes and
how human activities can influence water quality. Developed by the Stroud Water Research Center in cooperation with LaMotte Company. Materials for 30 students working in groups.
Topsoil Tour
Topsoil Tour, Order Code5425-01 (Ship Code NH; 4 lbs.)
Reagent Refill, Order Code R-5425-01 (Ship Code NH; 1 lb.)
Investigate the physical and chemical properties of soil. Each student on the Topsoil Tour completes seven
units while conducting his/her own soil tests for soil texture, pH, nitrogen, phosphorus, and potassium. Tablets
and sample test bags for 50 students.
Pondwater Tour
Pondwater Tour, Order Code 5418 (Ship Code R1; 4 lbs.)
Reagent Refill, Order Code R-5418 (Ship Code R1; 1 lb.)
A great introduction to the study and measurement of changes in the water quality of a lake, stream, pond,
aquarium, or even a fish bowl. Tests are included for pH, dissolved oxygen, nitrate, and ammonia. Students
test variables and investigate natural processes that create changes in water quality. Tablets and sample
test bags for 50 students.
Tapwater Tour
Tapwater Tour, Order Code 3608 (Ship Code NH; 4 lbs.)
Regent Refill, Order Code R-3608 (Ship Code NH; 1 lb.)
An exciting investigation of water quality examining the chemical properties of water directly from the tap.
Students learn the relationships between good and poor water quality while examining the pH, chlorine, hardness, copper, and iron of tapwater from their homes. Tablets and sample test bags for 50 students. Ideal for
educational outreach for public health/utilities.
Call For Our Science Education Products Catalog
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
59
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
AP® Water Quality Assessment Package
Order Code 5845-PKG (Ship Code NH (1)
The AP® Environmental Science WATER QUALITY ASSESSMENT PACKAGE is
an extensive curriculum that uses the exploration of the Water Quality
Index to teach students STEM-based skills that they will apply through
classroom and field activities to satisfy Section VI (Water Pollution)
of the AP® Environmental Topics Outline.
In a culminating field activity, students utilize appropriate
techniques and instrumentation to identify their watershed and perform chemical and biological analyses to
determine the water quality index of a local waterway.
In four classroom activities, students
use actual data from the Kansas River
watershed to:
ƒƒ Perform independent research
ƒƒ Analyze data
ƒƒ Create spreadsheets
ƒƒ Calculate the water quality index
ƒƒ Generate graphs
ƒƒ Collect data
ƒƒ Perform statistical analysis
ƒƒ Access real-time hydrological data
ƒƒ Locate local watersheds
ƒƒ Observe environmental systems
ƒƒ Communicate accurately
The
following environmental concepts are covered: watersheds, Water Quality Index, physical, chemical and biological water quality
parameters, nutrient loading, hydrological variables, watershed ecology, remediation measures, and
point, non-point pollution sources.
The Teacher Resource CD-ROM (included with the Water Quality Index Module) contains:
ƒƒ Teacher/Student guide
ƒƒ Water Quality Test Procedures
ƒƒ STEM Extension Activities
ƒƒ Chemical Reactions
ƒƒ Data Spreadsheets
ƒƒ Glossary
ƒƒ Graphics Files
ƒƒ PowerPoint Presentations and Quick Time iPad/iPod Videos
Also includes a Free LaMotte BioPaddle Colony Identification App which lets users capture the BioPaddle image to compare the “unknown” microbe growth on the BioPaddle to a library of photos of
“known” microbe colonies.
Water Quality Assessment Curriculum Module, Code 5845
(separately)
ƒƒ Nutrient – TTC/MacConkey BioPaddles (Code 5553) for coliform
testing
ƒƒ Salt/TDS/Temp Tracer (Code 1749-01) for temperature and TDS
determination
ƒƒ Teacher Resource CD-ROM
Water Quality Educator, Code 5870-01 (See page 57)
ƒƒ Thermometer, Armored, Code 1066
ƒƒ Dissolved Oxygen Kit, Code 5860-01
ƒƒ pH Kit, Code 5858-01
ƒƒ Nitrate-Nitrogen Kit, Code 3354-01
ƒƒ Phosphate Kit, Code 3121-02
ƒƒ Turbidity Kit, Code 7519-01
ƒƒ Alkalinity Kit (Code 4491- DR -01)
GREEN Low-Cost Water Monitoring Kit
Order Code 3-5886 (Ship Code NH; 1 lb.)
A popular, economical tool for learning the basics of water quality.
Students will have fun analyzing sample water for pH, Dissolved Oxygen, Biochemical Oxygen Demand, Temperature, Turbidity, Nitrate,
Phosphate, and Coliform Bacteria. Includes a manual with step-by-step
diagramed instructions and easy-to-use laminated color chart. All the
necessary apparatus and non-hazardous TesTabs to test ten water
samples (three samples for Coliform). Ideal for educational outreach.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
60
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Food/Laundry
Dairy Producers, Food Processors, Commercial Launderers
Food Sanitizer Kits
For Caustic Soda
Model TK-10, Order Code 8225-01 (Ship Code R2; 2 lbs.)
Reagent Refill, Order Code 8225-H (Ship Code R2; 2 lbs.)
This simple, single-reagent dropper pipet kit measures caustic soda for
cleaning dairy bottles, cans, storage tanks, etc. Reagents for 50 tests. Kit uses
neutralization test method. Dilution step permits measurement of two ranges:
ƒƒ 0.25%/drop caustic soda by weight
ƒƒ 0.01%/drop sodium oxide
Also Available...
Factor
Order Code
Method
Range (# Test)
Sulfuric Acid
Chlorine
Chlorinated Cleaner
8205
4497-01
8226
Neutralization
Iodometric
Neutralization
0.05 oz. per gal/drop (50)
10 ppm/drop (50)
0.01% NaOH/drop (50)
Ship Codes
R2
R2
R2
Standard pH Test Papers
Order Code
pH Range
Order Code
pH Range
2907
2912
3-2950
2953
6.8–8.4
3.0–10.0
0-14
4.5–7.5
2954
2955
2956
2959
0–13
9–14
1–11
8–12
Sanitizer Test Papers and Strips
Chemically treated paper strips change to indicate sanitizer level. Strips and color chart are packaged in a
waterproof plastic vial. 2951 is specifically formulated to read all types of QAC.
Test Papers
Test Strips (50 test per vial)
Factor
Code
Range
Factor
Chlorine
4250-BJ
Iodine
2948-BJ
Peracetic Acid
3000
Peracetic Acid, Low Range 3000LR
QAC
2951
High Range
QAC
High Range
Chlorine
2951-HR
10, 50, 100, 200 ppm
(200 papers)
12, 25, 50, 100 ppm
(200 papers)
50, 100, 200, 400 ppm
(100 strips)
200, 400, 600, 1000, 1500 ppm
(50 strips)
0, 50, 100, 250, 500, 800 ppm
(50 strips)
3031
Code
Range
0, 10, 20, 40, 60, 85, 160
0, 5, 10, 20, 30, 50
Look for additional chlorine, iodine, & QAC kits in
the Individual Test Kit section
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
61
Food/Laundry
Dairy Producers, Food Processors, Commercial Launderers
Laundry Outfit
For control of water supplies, cleaning
operations, and rinses
Model LDR, Order Code 3095-02
(Shipping Code LQ)
Reagent Refill, Order Code R-3095-02
(Shipping Code LQ)
Seven important factors for monitoring incoming
water supplies, break, suds and bleach operations;
also rinse and sour operations. The pH (alkaline)
test uses a LaMotte Octet Comparator. The alkalinity tests, chlorine bleach and hardness test
utilize dropper pipet test methods. Reagents are
supplied for 50 tests of each factor.
Factor
Range
Application
Factor
Range
Application
pH (Alkaline)
pH (Sour)
Alkalinity
(Suds)
Alkalinity
(Rinse)
pH 10.0–11.4
pH 1.5–8.5
100 ppm/drop
Break-suds-bleach solutions
Sour rinse solutions
Free/total alkalinity in
break-suds-bleach solutions
Total alkalinity in rinses
Chlorine Bleach
0.5%/drop
Hardness
10 ppm or
1 gpg/drop
Yes/No (Soil)
Available chlorine in bleach
solutions
Water Supply
10 ppm/drop
Turbidity
Presence of soil in solution
Also Available...
Code
Description
7250-01 P Alkalinity 1 drop = 10 ppm or 100 ppm
Total Hardness 1 drop = 1 gpg
Chlorine Strips 10, 50, 100, 200 ppm
7196-01 Chlorine 1 drop = 10 ppm
Oxygenated Bleach 1 drop = 10 ppm
3541-01 Spot test for presence/absence of Chlorine
and Iron. Wide Range pH
7894-01 High Range–1 dr = 0.5% Cl2
Mid Range–1 dr = 0.05% Cl2
Low Range–1 dr = 0.005% Cl2
Ship Codes
R2
R2
R1
R1
7250-01
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
62
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
General Water Analysis
Laboratories, Government Agencies
SMART Water Analysis Laboratory
MODEL SCL-05, Order Code 1951-02 (Shipping Code LQ; 37 lbs.)
Reagent Refill, Order Code R-1951 (Shipping Code LQ; 10 lbs.)
This portable lab measures 24 water quality parameters for pollution detection, environmental studies, and industrial water and wastes. The SMART3 digital
colorimeter analyzes test sample color reactions and provides direct readouts for 15 factors. Titration tests performed with LaMotte’s Direct Reading Titrators provide results directly in ppm for 6 additional factors. Digital meters measure pH and conductivity.
See specifications on next page.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
63
General Water Analysis
Laboratories, Government Agencies
Colorimeter Tests
Titration Tests
Factor
Method
Ammonia
Chlorine
Bromine
Iodine
Chromium
(Hexavalent)
Copper
Fluoride
Iron
Nitrate
Nitrite
Phosphate
Silica
Sulfate
Sulfide
Turbidity
Nesslerization
DPD
DPD
DPD
Diphenylcarbazide
0–4.0 ppm (50)
0–4.0 ppm (100)
0–9 ppm (100)
0–16 ppm (100)
0–1.0 ppm (100)
Range (# Test)
Diethyldithiocarbamate
SPADNS
Bipyridyl
Cadmium Reduction
Diazotization/Coupling
Ascorbic Acid Reduction
Heteropoly Blue
Barium Chloride
Methylene Blue
Absorption (No Reagents)
0–6.0 ppm (100)
0–2.0 ppm (50)
0–6.0 ppm (50)
0–3.0 ppm (20)
0–0.8 ppm (20)
0–3.0 ppm (50)
0–4.0 ppm (50)
0–100 ppm (50)
0–1.5 ppm (50)
0–400 NTU (¥)
Factor
Method
Alkalinity
Neutralization
Carbon Dioxide
Neutralization
Chloride/Salinity
Argentometric
Dissolved Oxygen
Azide Modification
of Winkler Method
Complexometric
Hardness (Calcium,
Magnesium, & Total)
Range (# Test)
0–200 ppm
(50 at 200 ppm)
0–50 ppm
(50 at 50 ppm)
0–200 ppm
50 at 200 ppm)
0–10 ppm
(50 at 10 ppm)
0–200 ppm
(50 at 200 ppm)
pH/Conductivity Instruments
Factor
Code
Model
Range # Test)
pH
Conductivity
5-0034-01
5-0038-02
pH5
CON5
pH 0–14
0.0–19.99 mS
Also Available...
Model
Ship Code
(Wgt.)
Description
Code
Model SMART 3 Colorimeter,
without pH & Conductivity Lab
Meters
Reagent Refill
1991-01 SCL-04
LQ (34 lbs.)
R-1991
LQ (10 lbs.)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
64
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Industrial Waters
Water Treatment Companies, Engineers, Consultants
Combination Buret Outfits
In addition to our other standard products, LaMotte also packages combination buret style outfits. These outfits are packaged in cases made of
rugged ABS plastic in sizes to fit three to five burets and accessories. The automatic burets and accessories are mounted in plastic clips over a white
plastic workshelf in one half of the cabinet. The other half of the case is equipped with foam-lined shelves to hold additional tests or accessories.
Colorimetric and titrimetric tests may be added to the buret titrations.
To order, simply choose the desired test reagents from the list on page 66 and select any additional tests from the A - Z section (pages 39-55) or the
instrumentation section (pages 8-33). Squeeze valve (pinchcock) style burets are standard equipment with these kits, but glass or Teflon® stopcock
burets may be ordered for an additional charge.
Model AB-152
Model AB-153
Order Code 7643 (Ship Code LQ)
Order Code 7644-01 (Ship Code LQ)
Factor
Method
Equivalence (# Tests)
Factor
Method
Equivalence (# Tests)
pH
Alkaline Wide
Range
Stannous
Chloride
pH 8.5–12 (50+)
Molybdenum
pH
pH
Phosphate
Xanthate
Phenol Red
Alkaline Wide Range
Stannous Chloride
1–10 ppm Sodium Molybdate (50+)
pH 6.8 – 8.2 (50+)
pH 8.5 – 12 (50+)
0–10 / 0–100 ppm (50+)
Phosphate
0–10 / 0–100 ppm (50+)
Factor
Method
Equivalence (# Tests)
Factor
Method
Equivalence (# Tests)
Alkalinity
Chloride
Hardness
Sulfite
Neutralization
Argentometric
Complexometric
Iodometric
1 mL = 1.0 mg (50+)
1 mL = 0.5 mg (50+)
1 mL =6 0.25 mg (50+)
1 mL = 1.0 mg (50+)
Alkalinity
Chloride
Phosphonate
Sulfite
Neutralization
Argentometric
Complexometric
Iodometric
1 mL = 1.0 mg (50+)
1 mL = 0.5 mg (50+)
1 mL = 0.2 mg (50+)
1 mL = 1.0 mg (50+)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
65
Industrial Waters
Water Treatment Companies, Engineers, Consultants
Industrial Titration Reagents
Factor
Order Code
Reagent
Alkalinity
2246
2786
6068
6111
4069
8848
6346
6168
4259
T-5250
4483
4484
6261
6385
7329
6106
4556
8667
Phenolphthalein
Total Alkalinity Indicator
Sulfuric Acid, 0.02N
Sulfuric Acid, 0.1N
Chromate Indicator, 5%
Silver Nitrate, 0.0282N
Silver Nitrate, 0.0141N
Silver Nitrate, 0.0171N
Ca Buffer (w/ metal inhibitors)
Ca Indicator Tablets
Total Buffer (w/ inhibitor)
Total Indicator Tablets
EDTA, 0.01M
Starch Acid Indicator Powder
Iodide Iodate, N/40
Iodide Iodate, N/80
Iodide Iodate, N/63
Iodide Iodate, N/126
Chloride
Hardness
Sulfite
Available in a wide variety of sizes.
Call Customer Service for assistance.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
66
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Industrial Waters
Water Treatment Companies, Engineers, Consultants
For additional customer convenience, LaMotte has packaged a variety of combination kits. There are two choices of kit style, depending on the titration
method desired - Direct Reading Titration (DRT) or Dropper Bottle (WT).
If the combination needed is not listed, LaMotte offers a unique custom combination kit program. Simply choose the desired tests from the A - Z listing (pages 39-55) or the instrument section (pages 8-33). If you need a test equivalence or method different from what we offer, please contact us
with the specific requirement.
*When ordering the combinations below, please designate whether you wish the Direct Reading Titrator (-DRT) or Dropper Bottle (-WT) version.
Combination #2
DRT Version
WT Version
Reagent Refill Order Code 7178-DRT (Ship Code LQ; 7 lbs.)
Order Code 7178-WT (Ship Code LQ; 7 lbs.)
Order Code R-7178-WT (Ship Code LQ)
Factor
DRT
P/T Alkalinity
Chloride
Total Hardness
Sulfite
Phosphate
pH
0–200 ppm
1 drop = 10, 25, 50 ppm
0–200 ppm
1 drop = 10, 25, 50 ppm
0–200 ppm
1 drop = 2, 5, 10 ppm
0–100 ppm
1 drop = 2, 5, 10 ppm
2, 4, 6, 8 (20, 40, 60, 80) ppm Octet Comparator
4, 6, 8, 10 Octet Comparator
WT
Combination #3
DRT Version, Order Code 7179-DRT, (Ship Code R2; 7 lbs.)
WT Version, Order Code 7179-WT, (Ship Code R1; 7 lbs.)
Reagent Refill, Order Code R-7179-WT, (Ship Code R1)
Factor
DRT
P/T Alkalinity
Chloride
Total Hardness
Sulfite
Wide Range pH
Iron
0–200 ppm
1 drop = 10, 25, 50 ppm
0–200 ppm
1 drop = 2, 5, 10 ppm
0–200 ppm
1 drop = 2, 5, 10 ppm
0–100 ppm
1 drop = 2, 5, 10 ppm
3–10 ppm Octet
0.5–10 ppm Octet
WT
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
67
Pool & Spa Waters
Professionals, Public Operators, Private Owners
WaterLink® Spin Lab
ƒƒ So simple, anyone can use it!
ƒƒ Just fill disk with sample and Spin
ƒƒ All test results in 60 seconds
ƒƒ Precise wet chemistry
ƒƒ Pre-measured reagents and sample amounts
Code 3576
A revolutionary new in-store lab is here! Now let the innovative WaterLink® Spin photometer do all
your pool and spa water testing for you. Just fill one unique Spin reagent disk with water and vital
tests are done automatically.
In just 60 seconds all the test results are transferred into the DataMate 10 software on your computer and analyzed to display results and recommend precise treatment instructions. Remove the
disk and you’re ready for the next customer.
For more information scan
the code shown here or go to
www.lamotte.com/spin for
videos and more information.
This ground-breaking analysis system is so simple anyone can use it. Each sealed reagent disk
contains the precise amount of reagent needed to run a complete series of tests. No measuring
water, no mixing, no prep time or cleanup.
Chlorine Disk, Order Code 4330-H (50/pk)
Range
Free Chlorine
(ppm)
Total Chlorine
(ppm)
Bromine
(ppm)
pH
(pH)
Calcium Hardness
(ppm)
Total Alkalinity
(ppm)
Cyanuric Acid
(ppm)
Copper
(ppm)
Iron
(ppm)
0 to 15
0 to 15
0 to 33.0
6.3 to 8.6
0 to 1200
0 to 250
0 to 150
0 to 3.0
0 to 3.0
Borate
(ppm)
0 to 60
Biguanide Disk, Order Code 4331-H (50/pk)
Range
Biguanide
(ppm)
Biguanide Shock
(ppm)
pH
(pH)
Calcium Hardness
(ppm)
Total Alkalinity
(ppm)
Copper
(ppm)
Iron
(ppm)
0 to 15
0 to 15
6.3 to 8.6
0 to 1200
0 to 250
0 to 3.0
0 to 3.0
Borate
(ppm)
0 to 60
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
68
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Insta-TEST® Plus Strips
PopTop bottles make
Insta-TEST® strips
even easier!
The Insta-TEST 3, PRO400, and 5-way pool and spa test strips are the
only strips of their kind that do not require any specific waiting period.
Just dip the strip in the pool or spa for accurate and reliable results.
The 3-way test strip measures for Free Chlorine or Bromine, Alkalinity
and pH all on one strip. The 5-way test strip measures Free Chlorine
or Bromine, Total Chlorine, Alkalinity, pH and Total Hardness. Both are
sold in vials containing 50 strips. The PRO400 provides 100 strips
and measures the Free Chlorine or Bromine, Total Chlorine, pH and
Alkalinity. The PopTop bottle features a patented desiccant liner covering its base and sides, which provides substantially better moisture
protection and eliminates the need for a loose desiccant bag. Another
feature is the hinged cap, which eliminates the problem of loose caps
getting wet. Each bottle has a 30 month shelf life. Individual units are
available through local retailers, which can be found on our website
www.lamotte.com/insta.
®
The Sodium Chloride Insta-TEST® strip is an easy one step procedure
for measuring Sodium Chloride in salt-water pools. Just dip and read
to get results in only 20 seconds. The strip measures salt water pool
samples over the range of 1,500 to 5,000 ppm. Each bottle contains
50 strips in a convenient, black PopTop bottle. A desiccant liner inside
the bottle protects the strips from moisture intrusion and UV light.
The Wide Range pH and Total Chlorine Insta-TEST® strip identifies
how far out of range a pool or spa sample may be, before a variety
of treatment chemicals and test reagents are consumed. The Wide
Range strip provides quick and reliable results in just 15 seconds. The
strips are designed to measure Total Chlorine from 0 to 50 ppm and
pH from 4 to 10.
See pages 34-35 for additional test strips.
Code
Model
Free
Chlorine
Bromine
Total
Chlorine
Alkalinity
pH
Total
Hardness
2976
2977
2978
2998-H
Insta-TEST 3 Plus
Insta-TEST 5 Plus
Insta-TEST PRO 400 Plus
Insta-TEST Salt
0 to 10
0 to 10
0 to 10
—
0 to 20
0 to 20
0 to 20
—
—
0 to 10
0 to 10
—
0 to 240
0 to 240
0 to 240
—
6.2 to 9.0
6.2 to 9.0
6.2 to 9.0
—
—
50 to 800
—
—
2987-G
Insta-TEST Wide Range pH
—
—
0 to 50
—
4 to 10
—
Salt
—
—
—
1500 to
5000
—
Case
Pack Size
Ship
Code
12, 24 or 100
12 or 100
12 or 100
12 or 100
NH
NH
NH
NH
12
NH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
69
Pool & Spa Waters
Professionals, Public Operators, Private Owners
DipCell Series
The LaMotte DipCell color comparator is available in a competitive lineup of
kits for the pool operator and service pro.The DipCell comparator is simple to
use. Just dip the comparator into the water to get a sample, add reagents, cap,
mix, and read chlorine and pH immediately. Six color standards are provided
for wide-range chlorine from 0.5-10.0 ppm. The six standards included for pH
range from 6.8 - 8.2.
ƒƒ A wide range chlorine DipCell measures Chlorine from 0.5 - 10 ppm
ƒƒ Removable wall dividers inside the carrying case permit an easy upgrade
to larger 60 mL reagent sizes
ƒƒ “Handle-Top” carrying case is compact and rugged (7½” x 4½”)
ƒƒ Liquid DPD and Phenol Red offered in large volumes to do 144 or 288 tests
ƒƒ Color-coded instructions and reagents simplify analysis
ƒƒ Separate titration tube for Alkalinity and Hardness avoids cleaning pH cell before each test
ƒƒ Handbook included
Free
Chlorine
Total
Chlorine
pH
7011-01/
DT-3
0.5-10.0
0.5-10.0
6.8-8.2
# of Tests
50
0.5-10.0
144
0.5-10.0
288
50
0.5-10.0
144
0.5-10.0
288
144
6.8-8.2
144
6.8-8.2
288
Code/Model
7013/DL-51
# of Tests
7014/DL-60
# of Tests
Calcium
Hardness
Calcium Alkalinity
Acid Demand
Base
Demand
(This kit includes 50 DPD tablets for each Chlorine test)
—
1 drop = 10 ppm
70±
1 drop = 10 ppm
140±
—
1 drop = 20 ppm
70±
1 drop = 20 ppm
140±
—
Drop count
70±
Drop count
140±
—
Drop count
70±
Drop count
140±
Cya
Ship
Code
—
NH
—
0-100
50
—
—
R1
R2
Pool MGR. Series
All Tablet • Octa-Slide
Our rugged all tablet kit for the public pool operator. The precise Octa-Slide Comparator system is used to comply with regulatory standards. The Pool MGR. Series
includes diagramed instructions, saturation index calculator, water quality handbook, and the eight-standard Octa-Slide Comparator system for chlorine and pH,
all in a tough, blow molded carrying case. The Pool MGR. tablet series is supplied
with sufficient tablet reagents for 50 tests for Free Chlorine, Total Chlorine, and pH.
Tablet reagents for 20 tests are provided for Alkalinity, Hardness, and Cyanuric Acid.
Code/Model
Free
Chlorine
Total
Chlorine
pH
Total
Alkalinity
Calcium
Hardness
Acid Demand
Cyanuric
Acid
Ship
Code
3366-BR
3366/PM-41
3366-NJ/PM-41-NJ
3368/PM-51
3368-NJ/PM-51-NJ
3368-ABC/PM-51-NJ
Bromine
0.2-3.0
0.5-10.0
0.2-3.0
0.5-10.0
0.5-10.0
0-10.0
0.2-3.0
0.5-10.0
0.2-3.0
0.5-10.0
0.5-10.0
6.8-8.2
6.8-8.2
6.8-8.2
6.8-8.2
6.8-8.2
6.8-8.2
60-400
60-400
60-400
60-400
60-400
60-400
60-400
60-400
60-400
60-400
60-400
60-400
Calc.
Calc.
Calc.
Calc.
Calc.
Acid/Base drop titration
–
–
–
0-100
0-100
0-100
NH
NH
NH
NH
NH
NH
50
50
50
20
20
Calc. From Alk test result
20
NH
# of Tests
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
70
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Pool & Spa Waters
Professionals, Public Operators, Private Owners
PRO250
Our professional water analysis kits are supplied in durable, cases for years
of dependable service. Each unit features liquid reagent systems for chlorine and pH (capable of 280+ tests each). The liquid DPD reagent system is
provided to monitor chlorine, while pH is tested with a single liquid indicator.
Total Alkalinity, Calcium Hardness, Acid and Base Demand are analyzed with
drop count titrations. Cyanuric Acid is measured by turbidity. The PRO250
PLUS outfit includes all of the above plus Copper and Iron tests.
Every PRO250 SERIES kit includes color-coded caps to prevent mixups and
diagramed instructions to make testing a breeze. The Pool MGR. Water Quality
handbook and saturation index calculator are also included.
See the chart below for specifications.
Code/Model
7001-NJ/
PRO250-NJ
7002-NJ/
PRO250 PLUS-NJ
# of Tests
Free
Chlorine
Total
Chlorine
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0
288
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0
288
pH
6.8-8.2
6.8-8.2
288
Total
Alkalinity
Calcium
Hardness
Acid & Base
Demand
Cya
Copper
Iron
Ship
Code
1 drop =
10 ppm
1 drop =1
0 ppm
140+
1 drop =
20 ppm
1 drop =
20 ppm
140+
Drop count
0-100
–
–
R2
Drop count
0-100
0.1-1.0
0.1-1.0
R2
70 each
100
50
50
ColorQ PRO 7
Model PRO 7, Order Code 2056 (Ship Code R1; 2 lbs.)
The unique, multi-test ColorQ hand-held photometer reads SEVEN pool and spa test factors directly on a digital display. Featuring an innovative dualoptic design, the ColorQ provides more accuracy and more test factors. The ColorQ eliminates the need to visually determine slight color variations or
use look-up tables, thus taking the guesswork out of poolside water analysis.
Test Factor
Free Chlorine (DPD)
Total Chlorine (DPD)
Bromine (DPD)
pH
Calcium Hardness
Total Alkalinity
Cyanuric Acid
Range
Method
0-10.0 ppm
0-10.0 ppm
0-22.0 ppm
6.5-8.5 pH
0-700 ppm
0-250 ppm
0-125 ppm
Colorimeter
Colorimeter
Colorimeter
Colorimeter
Colorimeter
Colorimeter
Colorimeter
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
71
Pool & Spa Waters
Professionals, Public Operators, Private Owners
DPD TesTabs® - All new packaging for easier use!
As the only North American manufacturer of DPD tablets, LaMotte has replaced traditional foil-on-foil strip packaging with blister-style foil packaging. The
user can dispense each tablet into a small vial by pressing the tablet through the foil. This eliminates the need to manually tear open a foil packet and
carefully dispense the tablet. The package carries the customary 10 tablets per strip in a compact 3.35” x 1.35” size. In addition to the convenient package, the DPD #1R rapid dissolving formula for measuring Free Chlorine has been enhanced for faster dissolution. Listed below are visual grade tablets.
Quantity/Order Code
Tablet
Chlorine DPD #1 Rapid
Chlorine DPD #1 Instrument*
Chlorine DPD #3 Rapid
Chlorine DPD #3 Instrument*
Chlorine DPD #4 Rapid
Chlorine DPD #4 Instrument*
pH (Phenol Red)
Alk Test
Cyanuric Acid
Calcium Hardness
MPS-OUT
(Monopersulfate Eliminator)
50
100
1000
Ship
Code
6999A-H
6903A-H
6905A-H
6197A-H
6899A-H
6906A-H
6915A-H
3920A-H
6994A-H
6846A-H
6911A-H
6999A-J
6903A-J
6905A-J
6197A-J
6899A-J
6906A-J
6915A-J
3920A-J
6994A-J
6846A-J
6911A-J
6999A-M
6903A-M
6905A-M
6197A-M
6899A-M
6906A-M
6915A-M
3920A-M
6994A-M
6846A-M
N/A
NH
NH
NH
NH
NH
NH
NH
NH
NH
NH
NH
* Instrument DPD featuring ultra clear fast dissolving tablets.
DPD Liquid Reagents
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators
or colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available
Chlorine. DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents
are also available to measure pH, Hardness, Alkalinity, and Copper.
30 mL(1 oz.)
Code
DPD 1A
DPD 1B
DPD 3
P-6740-G
P-6741-G
P-6743-G
Ship Code
NH
R2
NH
60 mL (2 oz.)
Code
DPD 1A
DPD 1B
DPD 3
P-6740-H
P-6741-H
P-6743-H
Ship Code
NH
R2
NH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
72
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Water & Wastewater
Municipal & Industrial Water & Wastewater Systems
Wastewater Lab
Model SW-04
Order Code 7946-04 (Ship Code R3; 25 lbs.)
This self-contained laboratory includes a one liter plastic Imhoff
Cone with support stand and polycarbonate settleometer for
measuring settleability. Critical pH measurements are performed
with the pH 5, digital pH meter. A maintenance free, gel-filled
combination electrode, and three pH buffers (4.00, 7.00, 10.00)
are provided. The Wastewater Lab also includes the Dissolved
Oxygen (Code 5860-01) and Chlorine (Code 3176-01) test kits.
Factor
Free & Total Chlorine
Dissolved Oxygen
Settleable Solids
Settleability
Temperature
Meters
pH 5 meter
Method
Range (# Tests)
DPD-FAS
Winkler
Gravimetric
Gravimetric
——
0–10 ppm (50)
0–10 ppm (50)
0–1000 mL/L(Unlimited)
0–100% (Unlimited)
–5° to 50°C (Unlimited)
Range
0–14 pH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
73
Water & Wastewater
Municipal & Industrial Water & Wastewater Systems
Storm Drain Monitoring Kit
Model SSDK, Order Code 7446 (Ship Code LQ; 8 lbs.)
Reagent Refill, Order Code R-7446 (Ship Code LQ)
The Model SSDK Detection Kit was specifically designed and manufactured to meet
US EPA requirements for field test procedures approved in the November 16, 1990
Federal Register to monitor illicit storm drain connections. Each unit includes tests
for pH, Total Chlorine, Total Copper, Phenols, Detergent surfactants, and Turbidity.
The Model SSDK is packaged in a rugged portable carrying case for on-site use.
Reagents are provided for 100 tests of each parameter (30 tests for Detergent).
Factor
Method
Phenols
4-Aminoantipyrine Slide
Copper
Thiocarbamate Slide
Detergents
Titration
Chlorine
DPD Slide
Turbidity
Formazin Equivalent
Range (# Tests)
0-5.0 ppm
0-4.0 ppm
0.1 ppm sensitivity
0.2-3.0 ppm
L-M-H
Meters
Range
Waterproof pH 1 PockeTester
0–14 pH, 0.2 pH
See pages 10-13 for information on Turbidity Meters
Corrosion Control Kit
Model CCK, Order Code 7436-01 (Ship Code R1; 7 lbs.)
Reagent Refill, Order Code R-7436-01 (Ship Code R1)
By determining corrosive conditions in water supplies, this test kit supports a
water supplier’s lead in drinking water abatement program. Each unit includes
tests for P and T alkalinity, calcium hardness, temperature, pH, phosphates,
and total dissolved solids. Calculate saturation index by the Langelier method
to indicate the corrosive conditions in water supplies. The Model CCK Corrosion Control kit is packaged in a portable carrying case for on-site use.
Factor
Method
Range (# Tests)
Calcium Hardness
P & T Alkalinity
Orthophosphate
Temperature
Complexometric
Neutralization
Ascorbic Acid
———
Corrosion Index
———
0–200 ppm(50)
0–200 ppm (50)
0.5–10 ppm (50)
–5° to +45°C
(Unlimited)
By calculation
via chart (50)
Meters
Range
Waterproof pH 1 PockeTester
Waterproof TDS 1 PockeTester
0–14 pH
10–1990 ppm
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
74
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Water Conditioning
Residential & Commercial Water Treatment Specialists
Customize Your Water Quality Sales Demonstrations
LaMotte Model AT-Q Digital and AT Visual series outfits are the most popular and effective sales tools for on-site demonstrations. The tests
clearly demonstrate the benefits between untreated and treated water. For order codes see our website www.lamotte.com.
AT Visual Kit (5 tests)
Factor
Range
Hardness
pH
Iron
Precipitation
Soap Consumption
1 drop = 10 ppm / gpg
5.0 - 10.0 pH
0.5-10.0 ppm*
Before/After
Before/After
# Tests
100
50
50
100
100
Kits come
with your
choice of
softeners
listed below.
AT-Q Digital Kit (8 tests)
Factor
Range
Resolution
# Tests
Hardness
pH
Iron
Nitrate
Chlorine
Sulfide
Precipitation
Soap Consumption
1-41 gpg*
5-9 pH
0.0-3.0ppm*
0-25 ppm
0-10 ppm
0-3.0 ppm*
Before/After
Before/After
1 gpg
0.2 pH
0.1 ppm
1 ppm
0.1 ppm
0.1 ppm
—
—
140
70
50
50
50
120
100
100
*Higher Concentrations by dilution, instructions included.
Demonstration Softener Units
Model S
Duo-SoftTM
DirectFlo
DirectFlo DuoSoft
Order Code 1002
ƒƒ Single chamber
ƒƒ Filled with resin
Order Code 1022
ƒƒ Dual chamber
ƒƒ Shipped empty
Order Code 1022-FLD
ƒƒ Dual chamber
ƒƒ Filled with carbon
Order Code 1026
ƒƒ Hose Free
ƒƒ Single chamber
ƒƒ Filled with resin
Order Code 1028
ƒƒ Hose Free
ƒƒ Dual chamber
ƒƒ Filled with
carbon and resin
and resin
Please visit www.lamotte.com for details
Water Quality Outfit
Model AR-42, Order Code 3590-03 (Ship Code R1, 7 lbs.)
The simplest, most economical way to measure several water quality factors
with a single, portable outfit. Ideal for service applications. Easily customized
for your particular analytical needs.
Offers tests for pH, hardness, iron, and sulfide. Includes reagents for 50 tests
each for pH, hardness, and sulfide; 100 tests for iron.
Factor
Method
pH
Iron
Hardness
Sulfide
Wide Range
Bipyridyl
Titration
Pomeroy
Range (# Tests)
pH 5.0–10.0 (50)
0.5–10.0 ppm (100)
1 drop = 10 ppm/1 gpg (50)
0.2-20.0 ppm (50)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
75
Reagent Refills
How to use this section:
The reagent code number is followed by a letter which indicates the container size supplied for that reagent. The following table shows how those
letters correspond to container sizes - milliliters for liquids and grams
fo powder. When ordering a reagent, please include the appropriate letter suffix with the reagent code number to indicate the container size.
EXAMPLE: To order a 60 mL bottle of Phenol Red Solution (Reagent Code
Number 2211), use the letter “-H”, and order by code number “2211-H”.
NOTE: A reagent is available only in the sizes indicated under the kit’s
listing in this section.
How to Determine Reagent Manufacture and
Expiration Dates
On the lower, left corner of the label of each LaMotte reagent is a six
(sometimes seven), digit number. This is not a code number, but the lot
number of that reagent. A lot number records the date of manufacture
and identifies the reagent as part of a specific batch of reagent produced
on that date. The first two digits of the lot number identify the week, and
the third digit identifies the year of manufacture.
If the shelf-life of your reagent is unknown, one year from the date of
manufacture is still a good rule of thumb.
Code#
Suffix (Indicating Size)
Size
Kit Code
2036
2081-02
2107-01
2108
2109-01
2110-01
2111-01
2112-01
2114
2117
2118
2119
2120
2121
2123
2124-01
3036
3036-DR-02
3037-DR-01
3043-DR-01
3095-02
6483-H
FIRST AID EYE OR SKIN
Immediately flush with water
for 15 minutes.
INTERNAL- Drink plenty
of water. Call a doctor.
WARNING: This product
contains Phenolphthalein,
a chemical known to the
State of California to cause
cancer.
Conductivity
Neutralizing
Solution
60 mL
Read MSDS
39% Isopropanol, CAS
67-63-5; 5% Citric acid,
CAS 77-92-9; <0.1%
Phenolphthalein, CAS
77-.09-8. Harmful if
swallowed or inhaled.
Do NOT use near heat
or flame. Avoid contact
with eyes. Keep
container tightly closed
and out of reach of
children.
WARNING! FLAMMABLE
Read side panel before use.
LOT 521109
802 Washington Ave., Chestertown, MD 21620 USA • 410-778-3100 • MSDS: lamotte.com/msds
Lot# (Including Week, Year, & Batch Information)
3110-01
3114-02
76
-A
1
1mL
1 gram
-B
2
2 mL
2 grams
-C
5
5 mL
5 grams
-D
10
10 mL
10 grams
-E
15
15 mL
15 grams
-F
20
20 mL
20 grams
-G
30
30mL
30 grams
-H
60
60mL
60 grams
-J
120
120mL
120 grams
-K
250
250-285mL
1200-500 grams
-L
500
470-525mL
450-500 grams
-M
1000
950-1000mL
—-
-N
—-
3800mL
—-
3119-01
3121-02
3133
3138-01
3152-01
Reagent #
2220-H
2218-G
2212-G
2208-G
2209-G
2210-G
2211-G
2212-G
2213-G
2214-G
2215-G
2218-G
2218-G
2218-G
2218-G
2218-G
2302-G
2303-G
6410-E
6411PS-H
6410-E
6411DR-G
4483-E
4257-H
6522-E
6413-E
6412-H
6434-H
7941PS-H
2301-G
4483-E
4485-E
4487PS-H
2246-E
2230-E
6130PS-H
6323-H
6432-H
V-6278-H
V-6279-C
V-6282-G
V-6283-C
V-6278-J
V-6279-C
V-6282-H
V-6283-C
V-6282-G
V-6283-C
4509-D
4170-H
6377-D
6155-E
6378-E
6364-C
7745-E
6155-E
6165-D
6025-E
6158PS-H
Description
Range Finding Indicator
Wide Range
Cresol Red
Bromcresol Purple
Chlorophenol Red
Bromthymol Blue
Phenol Red
Cresol Red
Thymol Blue
Oleo Red B
LaMotte Purple
Wide Range
Wide Range
Wide Range
Wide Range
Wide Range
Acid Wide Range
Alkaline Wide Range
Ferroin
Nitrite DRT
Ferroin
Nitrite
Hardness 5
Hardness Titration
CM Indicator
QAC Indicator
Titration Reagent
Hypochlorite Indicator
Hypochlorite Reagent C
Nitro Green Indicator
Hardness Reagent 5
Hardness Reagent 6
Hardness Reagent 7
Phenolphthalein
Methyl Orange Indicator
Hydrochloric Acid 1N
Hydrochloric Acid 0.1N
Sour Indicator
Mixed Acid
Nitrate Reducing
Phosphate Acid
Phosphate Reducing
Mixed Acid
Nitrate Reducing
Phosphate Acid
Phosphate Reducing
Phosphate Acid
Phosphate Reducing
pH Adjustment
Starch Indicator
Iodine
Sodium Thiosulfate
Morpholine Indicator
Tetraphenylboron
Sodium Hydroxide
Sodium Thiosulfate
Xylenol Orange
Hydrochloric Acid
Thorium Nitrate
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Reagent Refills
Kit Code
3160
3176-02
3188
3195
3300
3304-01
3308-01
3312-01
3313-01
3314-01
3315
3316-01
3318
3319
3320-01
3321
3322-01
3328-01
3346-01
3347-01
3352-01
Reagent #
6484-H
6485-H
6486-S
6807-C
6905-H
6815-G
6495-E
6452-G
6454-H
6999-H
2218-G
2217-G
4450-G
4451-S
4566-E
6414-J
4498-E
4499-E
4500PS-H
4483-E
4485-E
4487PS-H
6267-H
3978LWT-H
3979WT-G
3982WT-G
6999-H
6905-H
6999-H
6905-H
6999-H
6905-H
6999-J
6905-J
4797WT-G
4798WT-G
6905-6999
6904-6906
4450-G
4451-S
V-6278-H
V-6279-C
4410-G
6405-G
4571-G
4467-E
4468-E
6405-C
4458-G
4459-E
4460-H
6999-H
6905-H
3962-H
3963-H
4450-G
4451-S
4453-S
V-6278-J
V-6281-C
Description
Molybdenum Buffer
Molybdenum Oxidizing
Molybdenum Indicator
DPD 1
DPD 3R
Ferrous Ammon. Sulfate
Control Reagent
Hydrogen Peroxide 1
Hydrogen Peroxide LR
DPD 1R
Wide Range
LaMotte Violet
Iron 1
Iron 2
QTC Cond
QAC Test
Chlorine 1
Chlorine 2
Chlorine 3
Hardness 5
Hardness 6
Hardness 7
Dechlorinating
Salicylate Ammonia #1
Salicylate Ammonia #2
Salicylate Ammonia #3
DPD 1R
DPD 3R
DPD 1R
DPD 3R
DPD 1R
DPD 3R
DPD 1R
DPD 3R
Ammonia Nitro. 1
Ammonia Nitro. 2
DPD 1, DPD 3
DPD 2, DPD 4
Iron 1
Iron 2
Mixed Acid
Nitrate Reducing
VM Phosphate
Reducing Reagent
Silica 1
Silica 2
Silica 3
Reducing Reagent
Sulfide A
Sulfide B
Sulfide C
DPD 1R
DPD 3R
Molybdate 1 HR
Molybdate 2 HR
Iron Reagent 1
Iron Reagent 2 Powder
Ferrous Iron Reagent
Mixed Acid Reagent
Color Developing Reagent
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Kit Code
3354-01
3363
3363-NJ
3366
3366-BR
3368
3467-01
3468-01
3509-01
3509-02
3519-01
3526
3541-01
3569-01
3582-01
3588-02
3592-01
3609
Reagent #
2799-H
NN-3703-H
6915-H
6905-6999
6915-H
6905-6999
6905-6999
6915-3box
6999-J
6915-3box
6905-6999
3920-4box
3870-E
3869-E
4493DR-H
4069-E
4070-H
WL-T-2311-J
WL-4450-H
WL-4451-D
WL-4493-H
WL-4487-H
WL-6460-H
WL-4259-E
WL-T-5250-J
WL-3808-H
P-6740-G
P-6741-G
P-6743-G
WL-7027-H
WL-4856-K
4483-E
4484-J
4487WT-H
4450-E
4451-S
2218
V-6278-J
V-6279-C
V-6281-C
6903-H
6197-H
6381-G
4100-G
5116WT-G
9078WT-G
3943-H
3944-H
3951-E
3945-E
3946-J
4255-H
3956-G
6203-J
2785-E
6903-H
6811-E
4259-E
T-5250-H
4487DR-H
Description
Nitrate 1
Nitrate 2
Phenol Red
DPD 1, DPD 3
Phenol Red
DPD 1, DPD 3
DPD 1, DPD 3
pH, Alk, Hard
DPD 1R
pH, Alk, Hard
DPD 1, DPD 3
pH, Alk, Hard, CYA
Alkalinity Indicator 1
Alkalinity Indicator 2
Alkalinity B
Chloride A
Chloride B
Alk 1
Iron 1
Iron 2
Alk Titrant
Hardness Titrant
Base
Hardness 1
Hardness 2
Copper
DPD 1A
DPD 1B
DPD 3
pH Indicator
Cyanuric Acid Rgt.
Hardness Reagent 5
Hardness Reagent 6 Tablets
Hardness Reagent 7
Iron Reagent 1
Iron Reagent 2 Powder
Wide Range Indicator
Mixed Acid
Nitrate Reducing
Color Developing
DPD 1
DPD 3
Hydrochloric Acid
O-Tolidine
Ferric Iron Test
Sour Indicator
Aluminum 1
Aluminum 2
Lead A
Lead C
Lead Indicator
Hardness Buffer
Manganese
Chloroform
Metal Inhibitor
DPD 1
Glycine
Sodium Hydroxide
Calcium Hardness
Hardness 7
77
Reagent Refills
Kit Code
3615-01
3619
3622-01
3624-01
3628-01
3632-01
3633-04
3634-04
Reagent #
V-6278-K
V-6279-D
P-6367-E
P-6368-E
6903-H
6811-E
6807-C
6905-H
3992DR-H
7646-G
3997-J
3998-H
3999-H
4001-S
4797WT-G
4798WT-G
2218-G
V-6278-H
V-6281-D
2311-Eg-E
4493DR-H
2246-E
4504-E
4505DR-H
6090-E
4483-E
4485-E
4487DR-H
4169-H
4167-G
7166-G
6141WT-G
4170PS-G
4253DR-H
4797WT-G
V-6278-H
V-6281-D
2311-Eg-E
4493DR-H
2246-E
4504-E
4505DR-H
6090-E
4483-E
4485-E
4487DR-H
4253DR-H
4798WT-G
Description
Mixed Acid
Nitrate Reducing
Copper A
Copper B
DPD #1 Tablets
Glycine Solution
DPD 1
DPD 3R
Chlorine/Bromine
Molybdenum Buffer
MO Buffer
Denatured Alcohol
MO Titrant
Carbazone
Ammonia Nitro. 1
Ammonia Nitro. 2
Wide Range, pH 3
Mixed Acid
Color Developing
BCG-MR Indicator
Alkalinity B
Phenolphthalein
Chloride 1
Chloride 2
Sulfuric Acid
Hardness 5
Hardness 6
Hardness 7
Sodium Thiosulfate
Mang. Sulfate
Alk. Pot. Iodide-Azide
Sulfuric Acid
Starch Indicator
Carbon Dioxide B
Ammonia Nitrogen 1
Mixed Acid
Color Developing
BCG-MR Indicator
Alkalinity B
Phenolphthalein
Chloride 1
Chloride 2
Sulfuric Acid
Hardness 5
Hardness 6
Hardness 7
Carbon Dioxide B
Ammonia Nitro. 2
Kit Code
3635-04
3639-SC
3640-SC
3641-01-SC
3642-SC
3643-SC
3644-SC
3645-SC
3646-SC
3647-02-SC
3648-SC
3649-SC
3650-SC
3651-SC
3653-SC
3654-02-SC
3655-SC
3656-01-SC
3658-01-SC
3659-01-SC
78
Reagent #
2218-G
3978LWT-H
3979WT-G
3982WT-G
V-6278-J
V-6281-C
V-6279-C
2311-Eg-E
4493DR-H
2246-E
4253DR-H
7460-E
7461-H
4169-H
4167-G
7166-G
6141WT-G
4170PS-G
4004WT-G
6364-C
T-3808-H
7865-C
7866-J
7867-J
7868-E
V-4797-G
V-4798-G
6903-J
6197-J
6811-E
6903-J
6811-E
V-6276-D
6446-E
3875-G
4128-G
V-4450-G
V-4451-C
V-6278-H
V-6279-C
V-6278-H
V-6281-C
3989-G
3990-E
3991-K
V-6282-H
V-6283-C
V-4458-G
V-4459-E
4460-H
4410-H
4842-D
4841-H
3956-G
4255-G
6565-E
3978-H
7457-D
7458-C
Description
Wide Range pH 3
Salicylate Ammon. 1
Salicylate Ammon. 2
Salicylate Ammon. 3
Mixed Acid
Color Developing
Nitrate Reducing
BCG-MR Indicator
Alkalinity Titration B
Phenolphthalein
Carbon Dioxide B
Salinity Indicator A
Salinity Titration B
Sodium Thiosulfate
Mang. Sulfate
Alkaline Pot. Iodide-Azide
Sulfuric Acid
Starch Indicator
Sodium Hydroxide
Tetraphenylboron
Copper Tablets
Aluminum Inhibitor
Aluminum Buffer
Aluminum Indicator
Aluminum Complex.
Ammonia Nitro. 1
Ammonia Nitro. 2
DPD 1
DPD 3
Glycine
DPD 1
Glycine
Chromium Rgt.
Copper 1
Acid Zirconyl Spadns
Sodium Arsenite
Iron 1
Iron 2
Mixed Acid
Nitrate Reducing
Mixed Acid
Color Developing
Indigo Blue Solution
Chlorine Inhibitor
Ozone Buffer
Phosphate Acid
Phosphate Reducing
Sulfide A
Sulfide B
Sulfide C
Phosphate Rgt.
Reagent B
Hydrazine A
Manganese Indicator
Hardness Buffer
Sodium Cyanide
Salicylate Ammon. 1
Salicylate 2
Salicylate 3
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Reagent Refills
Kit Code
3660-01-SC
3661-01-SC
3662-SC
3663-01-SC
3664-SC
3665-SC
3666-01-SC
3667-01-SC
3668-SC
3669-SC
3670-01
3670-LI-01
3671-01
3672-01
3673-01
3674-01
3676-01
3677-01
3678-01
3679-01
3680-01
3681-01
3682-01
3683-01
Reagent #
6130-E
4004-E
2850PS-H
2794DS-C
2793DS-C
4856-K
6452-G
6454
6251PS-H
6253-K
6254-H
6537-H
6566-G
6346WT-G
V-4466-G
V-4467-G
V-4468-G
V-6284-D
V-6277-D
7833-G
7834-H
6314-G
6315-G
6565-E
6316-D
5128-G
6319-J
2776-E
2777-C
6310-D
6311-E
6903-J
6197-J
P-6740-G
P-6741-G
P-6743-G
6903-J
6811-E
6903-J
6446-G
3875-J
4128-H
6485-G
3997-H
6486-S
V-6278-J
V-6279-D
3989-G
3990-E
3991-K
V-6282-H
V-6283-D
V-4797-G
V-4798-G
2776-E
2777-C
4255-J
3956-G
6565-E
V-6277-D
Description
Hydrochloric Acid
Sodium Hydroxide
Cyanide Buffer
Cyanide CL
Cyanide Indicator
Cyanuric Acid Rgt.
Hydrogen Peroxide 1
Hydrogen Peroxide Tabs
Hydrochloric Acid
Sodium Citrate
Dimethylglyoxime
Ammonium Hydroxide
Ammonium Pers
Silver Nitrate
Silica 1
Silica 2
Silica 3
Silica 4
Sulfate Rgt.
Tannin 1
Tannin 2
Zinc Indicator
Zinc Buffer
Sodium Cyanide
Sodium Ascorbate
Formaldehyde
Methyl Alcohol
Acid Phenanthroline
Iron Reducing
Manganese Buffer
Manganese Periodate
DPD 1
DPD 3
DPD 1A
DPD 1B
DPD 3
DPD 1
Glycine
DPD 1
Copper 1
Acid Zirconyl SPADNS
Sodium Arsenite
Molybden. Oxidizing
MO Buffer
Molybdenum Indicator
Mixed Acid
Nitrate Reducing
Indigo Blue Solution
Chlorine Inhibitor
Ozone Buffer
Phosphate Acid
Phosphate Reducing
Ammonia Nitrogen 1
Ammonia Nitrogen 2
Acid Phenanthroline
Iron Reducing
Hardness Buffer
Manganese Indicator
Sodium Cyanide
Sulfate Rgt.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Kit Code
3687-SC
3688-SC
3698-SC
3699-03-SC
3700-01-SC
4-3003-01
4-8776
4031-01
4053-02
4068-01
4401-02
4408-01
4430-01
4447-01
4456-01
4463-01
4482-DR-LI-01
Reagent #
V-4466-G
V-4467-G
4468-E
4167-G
7166-G
6141WT-G
7681-H
V-6276-D
7683-E
7682-G
5115PT-H
3997-G
6485-G
6486-S
V-2209-H
V-2304-H
V-2213-H
4450-G
4451-S
2218-G
4767-H
4542-H
4543-H
4483WT-H
4484-J
4487WT-H
4133
4135
4134
4170
6377
3843
4032
6565
4033
4022
4054-L
4055-G
4056-G
4057-H
3965DR-H
4067A-J
6130-E
3929-E
4410-G
6405-G
4410-H
4431-G
4450-G
4451-S
4458-G
4459-E
4460-H
4571-G
4467-E
4468-E
6405-C
4483-E
4485-E
4487DR-H
Description
Silica 1
Silica 2
Silica 3
Manganous Sulfate
Alkaline Pot. Iodide-Azide
Sulfuric Acid
Sulfuric Acid
Chromium Rgt.
Sodium Azide
Potassium Permanganate
Deionized Water
MO Buffer
Molybdenum Oxidizing
Molybdenum Indicator
TRL Chlorphenol Red
TRL Phenol Red
TRL Thymol Blue
Iron 1
Iron 2
Wide Range Indicator
Soap 4
Precip A
Precip B
Hardness 5
Hardness 6
Hardness 7
DSP Reagent 10%
Borate Buffer
PSSA Reagent 5%
Starch Indicator
Iodine Solution 0.025N
Zinc Acetate 2.0N
Ammonia Chloride Buffer
Sodium Cyanide 10%
PAR Indicator
Stabilizing Reagent
Arsenic Reagent 1
Arsenic Reagent 2
Arsenic Reagent 3
Arsenic Test Strips
Thorium Nitrate 0.00132M
Phosphonate Tablet
Hydrochloric Acid 1N
Fluoride Inhibitor
VM Phosphate
Reducing Rgt.
VM Phosphate
Chromate Indicator
Iron 1
Iron 2
Sulfide A
Sulfide B
Sulfide C
Silica 1
Silica 2
Silica 3
Reducing Rgt.
Hardness 5
Hardness 6
Hardness 7
79
Reagent Refills
Kit Code
4482-DR-LT-01
4482-LI-02
4482-LT-02
4491-DR-01
4497-01
4497-DR-01
4501-01
4503-DR-02
4507-02
4515-01
4533-01
4533-DR-01
4630
4783-03
4790-01
4801
4801-DR-01
80
Reagent #
4483-E
4484-J
4487DR-H
4483-E
4485-E
4487WT-H
4483-E
4484-J
4487WT-H
T-2311-H
4493DR-H
4498WT-H
4499WT-H
4500PA-H
4498WT-H
4499WT-H
4500DR-H
4498-E
4499-E
3819-H
4504-E
2246-E
6090-E
4505DR-G
4508-G
4509-H
4513-E
7444-H
6037-J
7445-J
T-2246-J
T-2311-J
4493PS-H
T-2246-J
T-2311-J
4493DR-H
4633-H
4634-H
4635-H
4636-H
4636-J
4637-S
4638-S
4639-H
4640-H
4483-E
4484-J
4487WT-H
4450-G
4451-S
2218-G
4791-E
4792-E
4793-E
4802PS-H
4803PS-H
2299-E
4802DR-H
4803DR-H
2299-E
Description
Hardness 5
Hardness 6
Hardness 7
Hardness 5
Hardness 6
Hardness 7
Hardness 5
Hardness 6
Hardness 7
BCG-MR Indicator
Alkalinity Titration B
Chlorine 1
Chlorine 2
Chlorine 3
Chlorine 1
Chlorine 2
Chlorine 3
Chlorine 1
Chlorine 2
Sodium Thiosulfate
Chloride 1
Phenolphthalein
Sulfuric Acid
Chloride 2
DS Indicator
pH Adjustment
DS Reference
Detergent Reagent 1
Detergent Reagent 2
Detergent Reagent 3
Phenolphthalein
BCG-MR Indicator
Alkalinity Titration B
Phenolphthalein
BCG-MR Indicator
Alkalinity Titration B
Sulfide Test 1
Sulfide Test 2
Sulfide Test 3
Sulfide Test 4
Sulfide Test 4
Sulfide Test 5
Sulfide Test 6
Sulfide Test 7
Sulfide Test 8
Hardness 5
Hardness 6
Hardness 7
Iron 1
Iron 2
Wide Range
DEHA 1
DEHA 2
DEHA 3
TDS A
TDS B
Methyl Orange
TDS A
TDS B
Methyl Orange
Kit Code
4824-DR-LT-01
4824-LT-02
4850
5858-01
5864-01
6616-01
6628-01
6662-01
6680
6701-01
6806
6817
6819
6824-01
6896-01
6955-01
6980
Reagent #
4259-E
T-5250-H
4483-E
4484-J
4487DR-H
4483-E
4484-J
4487WT-H
4259-E
T-5250-H
4841-H
4842-D
2218-G
3968A-H
3969A-H
6446-E
6630-D
6381-G
6319-H
1157
6155-E
6165-D
6025-E
6158PS-H
6697-J
6698-C
6699-J
6807-J
6382-F
6383WT-H
6809-H
6810-G
6811-J
6520-H
6813-K
4128-H
6815-J
5115PS-K
5115PT-K
6999-H
6905-H
6999-H
6905-H
6811-E
6905-H
6977-J
6999-J
6915-H
6977-H
6999
6904
6905
6899
6915
Description
Sod. Hydroxide
Calcium Hardness
Hardness 5
Hardness 6
Hardness 7
Hardness 5
Hardness 6
Hardness 7
Sod. Hydroxide
Calcium Hardness
Hydrazine A
Hydrazine B
Wide Range Indicator
Ammonia #1 Tab
Ammonia #2 Tab
Copper 1
Molybdenum Rgt.
Hydrochloric Acid
Methyl Alcohol
Filter Paper
Sodium Thiosulfate
Xylenol Orange
Hydrochloric Acid
Thorium Nitrate
Formaldehyde 1
Formaldehyde 2
Formaldehyde 3
DPD 1
EDTA Disodium Salt
Steadifac
Potassium Iodide
Potassium Iodide
Glycine
Sulfuric Acid
Sodium Bicarbonate
Sodium Arsenite
Ferrous Amm. Sulf.
Deionized Water
Deionized Water
DPD 1R
DPD 3R
DPD 1R
DPD 3R
Glycine
DPD 3R
Bromine Tablets
DPD 1R
Phenol Red
Bromine Tablets
DPD 1R
DPD 2R
DPD 3R
DPD 4R
Phenol Red
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Reagent Refills
Kit Code
7001-NJ
7148-01
7611
7002-NJ
7011-01
7013
7014
Reagent #
P-6740-H
P-6741-H
P-6743-H
P-7026-H
6994-J
P-7028-G
P-6111-H
P-4259-H
P-7030-G
P-7031-H
P-6068-E
P-6460-E
7886WT-E
4593WT-E
7184PS-G
6147WT-E
7185WT-G
6117-G
P-6740-H
P-6741-H
P-6743-H
P-7026-H
6994-J
P-7028-G
P-6111-H
P-4259-H
P-7030-G
P-7031-H
P-6068-E
P-6460-E
P-4450-E
T-4451-H
P-6446-E
6905-6999
P-7026-G
P-6740-G
P-6741-G
P-6743-G
P-7026-G
6994-HRB
P-6068-E
P-6460-E
P-7028-G
P-6111-G
P-4259-G
P-7030-G
P-7031-G
P-6740-H
P-6741-H
P-6743-H
P-7026-H
P-6068-G
P-6460-G
P-7028-G
P-6111-H
P-4259-H
P-7030-G
P-7031-H
Description
DPD 1A
DPD 1B
DPD 3
Phenol Red
Cyanuric Acid
Alk 1 Indicator
Alk Titrant
Hard 1
Hard 2
CaHard Titrant
Acid Demand
Base Demand
Sodium Hydroxide 15%
Nitric Acid 1:1
Silver Nitrate 0.011N
Ferric Ammonium Sulfate
Ammonium Thiocyanate Titrant
Barium Chloride 10%
DPD 1A
DPD 1B
DPD 3
Phenol Red
Cyanuric Acid
Alk 1 Indicator
Alk Titrant
Hard 1
Hard 2
CaHard Titrant
Acid Demand
Base Demand
Iron 1
Iron 2
Copper 1
DPD 1, DPD 3
Phenol Red
DPD 1A
DPD 1B
DPD 3
Phenol Red
Cyanuric Acid
Acid Demand
Base Demand
Alk 1 Indicator
Alk Titrant
Hard 1
Hard 2
CaHard Titrant
DPD 1A
DPD 1B
DPD 3
Phenol Red
Acid Demand
Base Demand
Alk 1 Indicator
Alk Titrant
Hard 1
Hard 2
CaHard Titrant
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Kit Code
7056-01
7057-01
7064-01
7068-01
7101-01
7101-DR-01
7105-03
7115
7132-01
7138-DB-01
7143-01
7144-01
7150-01
7171-02
7172-02
7175-01
Reagent #
7125-H
2258-E
6090-E
3995-G
7117-H
3996-H
3995-G
7117-H
2258-E
6090-E
6289-H
6289WT-H
5168-J
2246-E
7114-H
5175PT-K
4606-H
4607-J
7102-G
7103PS-H
7102-G
7103DR-H
7939PS-G
2790-H
6809-D
7118-J
7119-J
7121-H
7120-H
7122-H
7123-G
4804-J
2258-E
6385-D
2779WT-H
6809-D
4170WT-G
7139-H
7140-H
2780-D
6025-H
2781WT-H
4483-G
4485-E
2782WT-H
6809-D
4170WT-G
7456WT-H
7140-H
4483WT-G
4485-G
2783WT-H
6091WT-G
4069WT-G
6090WT-G
2258-E
3824WT-G
7327-E
7328-E
7329PS-H
Description
Polyquat Titrating
Phenolphthalein
Sulfuric Acid
Toluidine Blue O
EDTA
Quat Titrating
Toluidine Blue O
EDTA
Phenolphthalein
Sulfuric Acid
Sulfuric Acid
Sulfuric Acid
Sodium Hydroxide
Phenolphthalein
Glut. Test Powder
Distilled Water
Phosphate A
Phosphate B/C
Nitrite 1
Nitrite 2
Nitrite 1
Nitrite 2
Hypochlorite A
Hypochlorite D
Potassium Iodide
Barium Chloride
EDTA
Complex Solution
Sulfate Solution
Buffer
Indicator
Cation Exchange
Phenolphthalein
Starch Acid
Iodide Iodate
Potassium Iodide
Starch Indicator
Peroxide Titrant
Acidified Catalyst
T.C. Indicator
Hydrochloric Acid
T.C. Titrant
Hardness 5
Hardness 6
Free Chelant Titrant
Potassium Iodide
Starch Indicator
Peroxide Titrant
Acidified Catalyst
Hardness 5
Hardness 6
Hardness 10
Hydrogen Peroxide
Chloride A
Sulfuric Acid
Phenolphthalein
Silver Nitrate
Sulfite A
Sulfite B
Sulfite C
81
Reagent Refills
Kit Code
7175-DR-01
7181-01
7182-01
7183-02
7191-02
7196-01
7240-02
7246-02
7247-01
7250-01
7253-01
7253-DR-01
7282
7297-DR-01
7307
7340-R-01
7387-02
82
Reagent #
7327-E
7328-E
7329DR-H
5649WT-G
2258-E
6117-G
5648-G
2258-E
6410-E
2789WT-G
6141WT-G
6410-E
5650LWT-G
6521-G
S-6155-H
6434WT-G
4500WT-H
6452-G
2258-E
2786-E
7748WT-G
2788WT-G
4483WT-G
4485-G
6091WT-G
4069WT-G
6090WT-G
2258-E
6421WT-H
2246-G
4250-BJ
4483-G
4485-G
2783WT-H
6323WT-H
6130WT-H
7254-E
7255-E
6406PS-H
7254-E
7255-E
6406DR-H
7283-K
7284-J
7285-E
7287-C
7286-E
7288-J
0463
2246-E
4253DR-H
6456-H
7342-H
7343-H
7344-H
6130-E
4004-E
2850PS-H
2794DS-C
2793DS-C
2955
Description
Sulfite A
Sulfite B
Sulfite C
Hydrochloric Acid
Phenolphthalein
Barium Chloride
Sodium Hydroxide
Phenolphthalein
Ferroin
Can Solution
Sulfuric Acid
Ferroin
Hydrogen Peroxide
Potassium Iodide
Peracetic Acid Titrant
Hypochlorite
Chlorine 3
Hydrogen Peroxide 1
Phenolphthalein
Total Alkalinity
Sulfuric Acid
Hardness 2
Hardness 5
Hardness 6
Hydrogen Peroxide
Chloride A
Sulfuric Acid
Phenolphthalein
Silver Nitrate
Phenolphthalein
Chlorine Test Papers
Hardness 5
Hardness 6
Hardness 10
Hydrochloric Acid
Hydrochloric Acid
Iodine 1
Iodine 2
Iodine 3
Iodine 1
Iodine 2
Iodine 3
Reagent 1
Reagent 2
Reagent 3
Reagent 4
Reagent 5
Reagent 6
Filter Paper
Phenolphthalein
Carbon Dioxide B
Sulfate Turb
PPK A
PPK B
PPK C
Hydrochloric Acid
Sodium Hydroxide
Cyanide Buffer
Cyanide CL
Cyanide Indicator
pH Test Paper
Kit Code
7391-02
7414
7416-02
7417-02
7418-02
7419
7420
7421
7436-01
7443
7446
Reagent #
7393-G
7361-E
4167-G
7166-G
6286-H
4169-H
4170WT-G
4410-G
6405-G
7393-G
7361-E
4797WT-G
4798PS-H
4167-H
7166-H
6286-J
4169-J
4170-H
2843-H
3761-H
3760-H
3756-H
4167-H
7166-H
5172-H
4169-L
4170-J
2843-K
3760-K
3761-K
3756-K
3-0002
7423-G
7424-G
7797-D
3870-E
3869-E
4493DR-H
4259-E
T-5250-H
4487DR-H
V-6282-H
V-6283-C
2881-H
6899-H
7825-C
7826-G
7827-H
7444-J
6037-K
7445-J
6446-E
2881-H
6446-G
6899-J
7825-D
7826-H
7827-J
7444-H
6037-J
7445-J
Description
Zinc Rgt.
Zinc Conditioning
Manganous Sulfate
Alkaline Pot Iodide-Azide
Sulfamic Acid
Sodium Thiosulfate
Starch Indicator
VM Phosphate
Reducing Rgt.
Zinc Rgt.
Zinc Conditioning
Ammonia Nitrog. 1
Ammonia Nitrog. 2
Manganous Sulfate
Alkaline Pot Iod-Azide
Sulfamic Acid
Sodium Thiosulfate
Starch Indicator
Phosphate Buffer
Magnesium Sulfate
Ferric Chloride
Calcium Chloride
Manganous Sulfate
Alkaline Pot. Iod-Azide
Sulfuric Acid
Sodium Thiosulfate
Starch Indicator
Phosphate Buffer
Ferric Chloride
Magnesium Sulfate
Calcium Chloride
Polyseed BOD
Nitrite Nitrogen A
Nitrite Nitrogen B
Nitrite-Nitrogen CR
Alkalinity 1
Alkalinity 2
Alkalinity Titration B
Sod. Hydroxide
Calcium Hardness
Hardness 7
Phosphate Acid
Phosphate Reducing
pH 7.00 Buffer
Chlorine DPD #4R
Aminoantipyrine
Ammonium Hydroxide
Pot. Ferricyanide
Detergent 1
Detergent 2
Detergent 3
Copper 1
pH 7.00 Buffer
Copper 1
DPD 4R
Aminoantipyrine
Ammonium Hydroxide
Pot. Ferricyanide
Detergent 1
Detergent 2
Detergent 3
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Reagent Refills
Kit Code
7459-02
7514-01
7515-01
7516-DR-02
7518
7519-01
7523
7525
7530-DC
7530-DR-01
7530-WT-01
7605
7625-01
7625-DR-01
7634-DC-01
7634-DR-01
7658
Reagent #
7460-E
7461DR-G
6807-C
6905-H
3992WT-H
T-2246-J
T-2311-J
6117-G
6102PS-H
5115PT-H
6073-G
2246-E
6251DR-G
7217-H
7218-G
5115PT-J
7520-H
6058-H
2246-E
4253PS-H
6130-E
6155-E
6165-D
6158PS-H
3929-E
6130-E
6155-E
6165-D
6158PS-H
3929-E
6130-E
6155-E
6165-D
6158WT-H
3929-E
7607-J
6290-E
6203-J
6155-E
6323-E
3964-E
3965-H
6130-E
6155-E
6323-E
3965-H
6130-E
3964-E
6130-E
6155-E
6158PS-H
2202-G
6165-D
2202-G
6130-E
6155-E
6165-D
6158PS-H
7659-G
7660-G
7661-HS
Description
Salinity A
Salinity B
DPD 1
DPD 3R
Chlorine/Bromine
Phenolphthalein
BCG-MR Indicator
Barium Chloride
Alkalinity Titrant
Deionized Water
Barium Chloride
Phenolphthalein
Hydrochloric Acid
Manganese A
Manganese B
Deionized Water
Standard Turbidity
STD Color
Phenolphthalein
Carbon Dioxide B
Hydrochloric Acid
Sodium Thiosulfate
Xylenol Orange
Thorium Nitrate
Fluoride Inhibitor
Hydrochloric Acid
Sodium Thiosulfate
Xylenol Orange
Thorium Nitrate
Fluoride Inhibitor
Hydrochloric Acid
Sodium Thiosulfate
Xylenol Orange
Thorium Nitrate
Fluoride Inhibitor
Amine Indicator
Sulfuric Acid
Chloroform
Sodium Thiosulfate
Hydrochloric Acid
Chrome Azurol S
Thorium Nitrate
Hydrochloric Acid
Sodium Thiosulfate
Hydrochloric Acid
Thorium Nitrate
Hydrochloric Acid
Chrome Azurol S
Hydrochloric Acid
Sodium Thiosulfate
Thorium Nitrate
Meta Cresol Purple
Xylenol Orange
Meta Cresol Purple
Hydrochloric Acid
Sodium Thiosulfate
Xylenol Orange
Thorium Nitrate
Sulfuric Acid
Ferroin
Ceric Ammon. Nit.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Kit Code
7674-01
7678-01
7759
7778-01
7787-01
7791-DR-02
7802
7824
7831-01
7839-02
7857
7884
7894-01
7894-DR
8205
8225-01
8226-01
Reagent #
7423-G
7424-G
7797-D
7681-H
7683-E
7682-G
V-6276-D
5115PS-H
7756-J
7757-S
7758-J
6456-H
4450-G
4451-S
2786-E
6111DR-H
6248DR-H
4483-E
4484-J
4487DR-H
6251PS-H
6537-H
6253-J
6254-H
6566-G
6346-G
5115PT-J
7826-G
7827-H
7825-C
7833-E
7834-H
4427-J
6565-E
7841-E
7886PS-G
7837-E
6376-H
3016-E
7885-H
7886-J
2246-E
6566-G
5115PT-J
7888-D
7939PS-G
7940-G
7941PS-H
7939PS-G
7940-G
7941DR-H
8215-H
2786-E
8228-H
8230PA-H
8233PA-H
8234PA-H
Description
Nitrite Nitrogen A
Nitrite Nitrogen B
Nitrite-Nitrogen CR
Sulfuric Acid
Sodium Azide
Potassium Perman.
Chromium Reagent
Deionized Water
Silver 1
Silver 2
Silver 3
Sulfate Turb
Iron 1
Iron 2
Total Alkalinity
Sulfuric Acid
Sodium Hydroxide
Hardness 5
Hardness 6
Hardness 7
Hydrochloric Acid
Ammonium Hydroxide
Sodium Citrate
Dimethylglyoxime
Ammon. Persulfate
Silver Nitrate
Deionized Water
Ammon. Hydroxide
Pot. Ferricyanide
Aminoantipyrine
Tannin 1
Tannin 2
Lead Dithizone
Sodium Cyanide
Potassium Sodium
Sodium Hydroxide
SDMBT 1
SDMBT 2R
Formaldehyde
Sulfuric Acid
Sodium Hydroxide
Phenolphthalein
Ammon. Persulfate
Deionized Water
Boiling Stones
Hypochlorite A
Hypochlorite B
Hypochlorite C
Hypochlorite A
Hypochlorite B
Hypochlorite C
Acid Titration
Total Alkalinity
TK-10 Rgt.
Chl. Cleaner 1
Chl. Cleaner 2
Chl. Cleaner 3
83
Apparatus
Beakers - BOD
Beakers
Glass beakers have thick, slightly flared top, with spout designed for excellent pouring. Designed from ASTM specifications E960, type I requirements. All sizes have marking area and white graduated volume scale.
Thomas® Polypropylene Beakers are polypropylene with superior chemical resistance. Ribbed for easy stacking. Meets ISO/DIS 7056 Standards
for Lab Plastic Accuracy. Autoclavable.
BOD Bottle, Disposable
300 mL
Disposable BOD bottles provide huge labor
savings and improved quality in any environmental laboratory. Lightweight, unbreakable
and recyclable disposable bottles offer safer
as well as convenience. Bottles are formed
from PET resin, the most easily recycled
plastic available. Simply use once and toss
in the recycling bin.
Order Code
Description
1230Z17
Disposable BOD Bottle, 300 mL (stopper not included)
1230Z99
Stoppers for BOD Bottles
BOD Polyseed
84
Glass Order Code
0410
Plastic Order Code
0944
Description
Beaker, 50 mL
0415
0896
Beaker, 100 mL
0414
2-2011
Beaker, 150 mL
0596
—
Beaker, 200 mL
0411
0609
Beaker, 250 mL
2-2024
2-2013
Beaker, 400 mL
0412
2-2014
Beaker, 600 mL
2-2027
—
Beaker, 1,000 mL
Polybac Corporation Polyseed®
For producing acclimated seed for fast, economical BOD5 analyses
with consistent results. Each capsule contains 100 mg for specialized,
lyophilized bacterial cultures. Contents of capsule are added to 500 mL
of APHA standard nutrient water at 20°C and stirred for 60 minutes.
Resultant mixtureprovides enough acclimated seed for up to 250 BOD
tests. EPA accepted.
Order Code
Description
3-0002
Polyseed®, Pk 50
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Apparatus
Bod - Cleaners
N-CON BOD-Cubator
Burets
No modifications to refrigerator necessary; your refrigerator can be
temporarily converted to meet peak loads. Thermostat control alternates
operation of its heater’s and the refrigerator’s cooling system to maintain
temperature over range 5° to 40 °C.
Twelve inch high, self-leveling, glass burets
are graduated from 0–10 mL in 0.1 mL
increments. Available with rubber squeeze
valve, glass stopcock, or Teflon® stopcock.
Buret-24 assembly includes empty 250
mL bottle of natural, low density polyethylene which attaches to 24 mm screwcap
on buret stem. Buret-28 assembly has
250 mL bottle of amber polyethylene and
28 mm cap. Bottle serves as titrant reservoir; a gentle squeeze forces titrant into
buret, where it automatically levels on 0
mL mark at top of scale.
Order Code
6124-N10
Description
BOD-Cubator
Flask/BOD Bottle Brush
Allows access to entire inside surface of flasks or BOD bottles. Black
hog bristle brush 4¼ in. long mounted on a flat steel shank attached
to a pivoting shaft.
Buret Type
Rubber Squeeze
Order Code
With Poly
Bottle
0847-24
Order Code
With Amber
Bottle
0847-28
Order Code
Buret & Caps
Only
0427
Glass Stopcock
0827-24
0827-28
0826
Teflon Stopcock
0996-24
0996-28
0997
Cleaners
Order Code
Description
1929-R35
Brush, 16 in, Pk 3
Imhoff Cone Brush
Conical shape with tufted bristle and sturdy twisted wire handle. Black
bristles combine with stiff fibers, shaped to fit into cone tip. Bristle part
9 in. long, 4 in. top diameter, 1½ in. bottom diameter, tip 3 in. long, length
including handle 30 in.
Alconox® Biodegradable
Cleaning Compound
Mild, odorless, non-toxic powdered wetting agent and detergent for cleaning
glassware, porcelain, metal, plastic, or
rubber. Suitable for use in ultrasonic
cleaners. Usual dilution 1 tablespoon to
1 gallon water.
Order Code
2902-G05
Order Code
1930-D10
Description
Alconox, 4 lb Box
Description
Brush, Imhoff cone
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
85
Apparatus
Cleaners - Coliform
Cleaners (Continued)
Coliform
Kimberly-Clark Kimwipe® Absorbent
Light-Duty Wiper
Thomas® Coliform Water Sample Bag
Single-ply premium lab wiper for extra low-lint performance. Won’t scratch delicate surfaces. LINTGUARD® polyshield reduces lint and electrostatic
discharge when dispensing. Gently absorbent for
light liquid pickup.
Order Code
2-2069
Description
4½ x 8½ single-ply in dispensing box, Bx 280
Twist tie top seals with a 5
mm wide metal strip. Large
textured label area. Meets
EPA requirements for microbiological samples for
potable water according to
Standard Methods (Method 9060 A) or for NPDES
compliance monitoring.
Sterilized, with thiosulfate dechlorination tablet
included. 100 mL fill line
marked for easy reference.
Order Code
Description
1303-R90
Sample Bag, 100/bag
Coliform Bottles
COD Heater
120V and 230V, 12-tube capacity. This COD heater block features digital
microprocessor control, programmable time and temperature settings,
and a dual LED display to monitor both temperature and timer. Perfect
for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests
requiring digestion. See page 14 for additional specifications.
ƒƒ Screw cap reduces leakage
ƒƒ High quality polystyrene
Quality bottle and cap configuration has been designed to reduce
leakage from the sample site to
the laboratory. Vial is marked indicating the 100 mL line to aid
in taking samples. Bottes will not
fluoresce under black light. Available pre-preserved with sodium
thiosulfate and sterilized.
Order Code
9853-Q70
Description
Coliform Bottle, Non-sterile
9856-Q72
Coliform Bottle, Sterile
9856-Q74
Coliform Bottle, Sterile, Sodium Thiosulfate
Thomas® Coliform
Water Sampling Vial
Order Code
5-0102
Description
COD Heater Block, 120 V
5-0102-EX2
COD Heater Block, 230 V
Improved sample container for
microbiological testing. Ideal when
filtration or the Colilert® method is
used. Improved latching mechanism, won’t open or leak in transit. Pre-sterilized, with thiosulfate
tablet included. 120 mL fill line.
Order Code
9853-Q41
86
Description
Vial with tablet, Bg 100
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Apparatus
Cylinders - Flasks
Cylinders
Filter/Syringe Assembly
Glass cylinders have pouring spout and
permanent fused white graduations.
Plastic cylinders meet ASTM Class B,
E1272 standards and have excellent
heat and chemical resistance.
For on-site collection of filtrates or filtered material from natural or
industrial waters. Consists of 60 mL plastic syringe, dual check-valve,
Delrin® filter holder with Luer slip outlet and clear flexible PVC tubing,
3 ft. long x 5/8 in. i.d. Tubing attaches to check-valve outlet. Syringe is
calibrated to 0 to 60 mL and 0 to 2 oz.
Order Code
1050
0943
Description
Complete filter/syringe
assembly
Syringe, 60 mL
1175
Tubing, 36 in.
1174
Check-valve
0598
Filter Holder
Plastic
2-2076
Volume (Ml)
10
Graduation
Intervals (Ml)
0.2
Glass
Order Code
0416
2-2077
25
0.5
0417
2-2078
50
1.0
0418
2-2079
100
1.0
0419
2-2080
250
2.0
—
2-2081
500
5.0
0994
0947
Paper, 2.5 cm
2-2082
1,000
10.0
—
1157
Glass Fiber, 24 mm
Code 0598 holder acccepts the following
filters (furnished in packages of 100, unless
otherwise specified):
Membrane, 25 mm
Filter Paper
All papers listed are sold 100 to a package.
Diameter
(Cm)
1103
0.45 micron, pkg. 100
1180
0.2 micron, pkg. 100
Order Code
Alhstrom
Description
Speed
0463
No. 642-27, Qual.
11
Slow
0465
No. 642, Qual.
9
Medium
Whatman
0947
Nalge® Erlenmeyer
Flasks
No. 2, Qual.
2.5
Medium
0471
No. 2, Qual.
9
Medium
2-2098
No. 42, Ashless, Quan.
9
Slow
2-2100
No. 42, Ashless, Quan.
12.5
Slow
1157
Glass Fiber
2.4
—
Glass flasks have thick-walled
body with tapered contour to
minimize chipping. Approximate volumes are indicated.
Plastic flasks are polycarbonate with polypropylene screw
closures; use for preparation
and storage of culture media
and culturing techniques.
Flasks
Whatman® Quantitative
Ashless Filter Papers
Suitable for precipitates that are ordinarily
difficult to filter (2.5 mm particle retension).
Acid Wash, Ash Content 0.007%. Highly retentive for very fine analytical precipitates.
Recommended for use with vacuum.
Order Code
2-2098
Description
Filter Paper, 9 cm, Pk 100
4716-Q25
Filter Paper, 11 cm, Pk 100
2-2100
Filter Paper, 12.5 cm, Pk 100
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Plastic Order Code
2-2115
Description
Flask, 50 mL
Glass Order Code
0438
2-2116
Flask, 125 mL
0431
2-2117
Flask, 250 mL
0433
87
Apparatus
Flasks - Hydrometers
Flasks, Corning
Volumetric
Pyrex® Brand Class A. Heavy beaded,
heavy tubing neck with snap cap.
White block letters for easy readability.
Hydrometers
Specific Gravity 1 To 2
For liquids heavier than water. Approximate total length 305 mm, approximate length of graduate scale 135 mm, excepting range 1.000
to 2.000, which has scale approximately 150 mm long, and is made
without conventional enlarged bulb at bottom. Tolerance ±1 scale division. Require a cylinder 340x38 mm and approximately 250 mL of liquid.
Order Code
2-2150
Description
Hydrometer, 1.000-1.220: 0.002 interval
2-2151
Hydrometer, 1.200-1.420: 0.002 interval
2-2155
Hydrometer, 1.000-1.600: 0.005 interval
Corning Pyrex® Brand
Hydrometer Cylinder
Heavy wall construction. Large, hexagonal
base, sealed to the cylinder body, increases
stability.
Order Code
2-2127
Description
Flask, Volumetric, 50 mL
2-2128
Flask, Volumetric, 100 mL
2-2129
Flask, Volumetric, 500 mL
Order Code
2-2149
Description
Hydrometer Cylinder,
38 x 340 mm
Funnels, Plastic
Reinforced rim. Ridges outside and inside permit air passage and improve filtering efficiency. Withstand continuous use at temperatures
up to 130°C.
Order Code
2-2134
2-2135
Description
Funnel, 9 mL
Funnel, 20 mL
0459
Funnel, 37 mL
2-2137
Funnel, 95 mL
Magnifier
MacroLens
MacroLens with 5X magnification covers the entire petri dish. 4” diameter.
88
Order Code
5508
Description
MacroLens
5508-10
MacroLens 10 Pack
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Apparatus
Pipets - Stirrers & Accessories
Pipets: Bel-Art® Safety Bulb
Tapered silicone seal provides airtight fit in all pipet sizes. 2-2164 comes
complete with an elastic cord for dedicating pipettor to a specific reagent bottle.
Order Code
2-2164
Description
Safety Bulb
0395
Safety Bulb
Stirrer, Double
Magnetic
Designed for effecient sideby-side titrations. A lighted
On/Off switch indicates
power usage and individual
controls allow the operator
to regulate the rotation of
the stir bars. Includes two
stir bars. The ABS plastic
housing, 6.25”L x 3.25”W
x 2.5”H, has rubber feet
and a white plastic stirring
surface for clear determinations of end-point colors.
Order Code
1776
Description
Double Magnetic Stirrer without AC adapter
1744
AC Adapter only
Stirring Bars
Pipets: Corning Transfer Pipets
Octagon-shaped with rounded ends and
molded pivot ring.
Pyrex® Class A. Tapered at both ends. Calibrated to
deliver rated volume at 20°C.
Order Code
2-2170
Description
Transfer Pipet, 1 mL
2-2174
Transfer Pipet, 5 mL
2-2175
Transfer Pipet, 10 mL
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Magnetic Stirring Bar Retriever
For insertion or removal of magnetic stirring bars. Overall length 11½ in.
Order Code
2-2185
Description
Stirring Bar, x 1 in.
2-2186
Stirring Bar, x 1 in.
2-2187
Magnetic Pick Up Rod
89
Apparatus
Stirrers & Accessories - Thermometers
Stopcock Grease
Thermometer, Armored
Lubriseal® Stopcock Grease
A precision, NON-MERCURY thermometer encased
in a protective, plastic jacket. Window opening
views engraved graduation on white tubing which
increases readability. Full range of -5° to 45° in
0.5° increments.
For lubricating ground glass joints, glass, and metal stopcocks and
valves, and for sealing desiccators, anaerobic culture jars, and similar
utensils. Prevents the freezing of stopcocks, ground joints, etc. Low vapor
pressure, and resists attack by acidic and alkaline solutions. Smooth
textured, stable, free from vegetable or animal oil or silicone, and practically insoluble in water.
Order Code
2-2158-H
Order Code
1066
Full Range
-5° to 45°C in 0.5­° increments
Description
Lubriseal, 75g tube
Thermometer, Thomas® Switchable, °C/°F
8 in. thermometer with a wide range and digital display. Fits into cuvettes, test tubes, flasks, and beakers. Stainless steel probe is resistant
to acids, bases, solvents, and most laboratory chemicals. Dual range of
-58° to 302°F or -50° to 150°C. Digital resolution of 0.1° from -20° to
200°. Accuracy is ±1°C between -20° to 100°C. Readings updated every
second. Operates continuously for over a year on a single replaceable
silver-oxide battery (included). Supplied with protective case that can
be used as a holder.
Order Code
9329-H01
90
Description
Switchable Thermometer with Digital Display
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Free Catalogs
Aquaculture Testing Products
Code 1612
Test kits and instrumentation for critical water quality control of
aquarium systems. Designed for the hobbyist, retailer, and ornamental fish culturist. Test kits, instrumentation, and combination outfits
designed for fish farms, hatcheries, and research institutions. Equipment designed for monitoring water quality conditions on-site and
at benchtop locations.
Science Education Products
Code 1590
Practical, “hands-on” test equipment for air, soil and water chemistry
students in elementary, secondary, vocational, outdoor and college
science programs.
Pool & Spa Water Test Equipment
Code 1634
A complete line of test kits, combination outfits and labs for pool professionals, public pool or spa operators, and private pool or spa owners.
Product Price List
Code 1645
This “component price list” gives price and ordering information on
all standard LaMotte reagents, labware, apparatus and accessories.
Reagents are listed in kit-size and bulk containers.
Soil Testing Products
Code 1652
Field and laboratory test equipment for measurement of soil nutrients
and soil pH. For agricultural soils, greenhouses, gardens, dairy sanitation, aquaculture and hydroculture.
Water Conditioning Testing Products
Code 1650
Softener sales demonstration outfits and other specialized test equipment for the point-of-use water treatment industry.
Sanitation Testing Products
Code 1658
A comprehensive collection of test kits, test strips, and instruments
for use in Industrial and Food/Beverage applications.
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
91
Water & Soil Handbooks
A Study of Water Quality
Dr. Charles E. Renn;
46 pages
Examines the “life cycle” of water
from its occurrence in nature to its
treatment for domestic and industrial use, with emphasis on such
water quality problems as scaling,
corrosiveness, taste, and turbidity.
Order Code 1532
A Laboratory Manual for
Marine Science Studies
Staff, LaMotte Company;
32 pages
Test procedures and background
information on sampling and analysis in salt water environments oceans, bays, marine estuaries, and
salt marshes.
Order Code 1587
Investigating Water
Problems
Monitor’s Handbook
Pool Mgr. Handbook
Staff, LaMotte Co.; 71 pages
Dr. Charles E. Renn;
72 pages
A complete guide covering the importance of water quality of all types
of natural waters. Gives guidance for
watershed surveys, site location,
sample collection, and choosing appropriate methods and equipment.
Describes physical, chemical, and
biological factors of water quality,
and the analytical procedures for
their measurement. Provides the
basic program planning, data analysis, and reporting with conversion
factors, glossary, and resource list.
For individuals or groups starting a
water quality monitoring program.
Staff, LaMotte Company;
60 pages
Discusses 25 chemical factors of
water quality analytical procedures
for their measurement and interpretation of test results.
Order Code 1589
Limnology: An
Introduction to the Fresh
Water Environment
William A. Amos;
40 pages
Discusses biological, chemical,
and physical processes in ponds,
lakes, swamps, streams, and rivers
- stream dynamics, plant zonation,
the succession of ponds, the energy
cycle of ponds, etc.
Order Code 1593
Chemistry & Control of
Modern Chlorination
Dr. A.T. Palin; 64 pages
The process of chlorination and
principal methods of chlorine testing. Written by a leading international authority on chlorine measurement.
Order Code 1597
Marine Aquarium
Handbook
Staff, LaMotte Co.; 20 pages
Test procedures and background
information on chemical testing
for successful management of
aquarium water.
Order Code 1585
Order Code 1507
Our Environment
Battles Water Pollution
Dr. Charles E. Renn;
32 pages
Traces a theoretical river from its
origin as a mountain brook to its
discharge into a marine estuary, examining the chemical and biological
changes that occur as the stream
reacts to impurities from natural
and industrial sources.
Order Code 1592
A 60 page text for entry level lifeguards or aquatic supervisors. Discussions on water balance, sanitation, analysis, and problem solving.
Water treatment charts are provided.
Order Code 1505
A Study of Soil Science
Dr. Henry D. Foth;
44 pages
An introduction to soil formation,
soil pH, mineral elements and plant
nutrition, the life cycle of growing
plants, and soil fertility management.
Order Code 1530
The LaMotte Soil
Handbook
Staff, LaMotte Company;
60 pages
This “growers manual” discusses
major and minor nutrients, trace
elements, soil pH, organic matter,
soil texture, etc. Includes lime and
fertilizer recommendations for a
variety of crops and plants.
pH, Buffers & Acid/Base
Titrations
Order Code 1504
Staff, LaMotte Company;
20 pages
Plant Nutrition Studies
The theoretical and practical applications of acids and bases in
chemical testing.
Order Code 1595
Dr. Robert Stegner;
76 pages
Discusses the study and practice
of hydroponics - plant culture in
soilless solutions - and includes a
series of laboratory investigations.
Order Code 1596
92
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Standards
LaMotte has available a large variety of standards to be used in many applications.
Primary
Standards
Concentration
Order
Code
Quantity
(mL)
Shelf Life
Primary
Standards
Concentration
Order
Code
Quantity
(mL)
Shelf Life
Ammonia
Nitrogen
100 ppm
3871-H
60
2 yrs.
pH
2.0
2856-L
500
1.5 yrs.
Chlorine
250 ppm
6973-H
60
6 mo.
pH Buffer
Tablets
4.0
3983A-H
50 Tabs
3 yrs.
Chlorine
250 ppm
6973-L
475
6 mo.
4.0
3983A-J
100 Tabs
3 yrs.
Chlorine
Equivalent
1000 ppm
3858-H
60
6 mo.
pH Buffer
Tablets
pH
4.01
2866-J
120
1.5 yrs.
COD
Equivalent
500 ppm
7589-L
475
2 yrs.
pH
4.01
2866-L
500
1.5 yrs.
Color
500 cu
6058-H
60
3 yrs.
pH
4.01
2866-N
3800
1.5 yrs.
Color
500 cu
6058-L
500
3 yrs.
pH Color
Coded Red
4.01
3771-L
500
1.5 yrs.
Conductivity/
TDS
74 µS/52 ppm
6416-L
500
1.5 yrs.
Conductivity/
TDS
84 µS/59 ppm
6312-L
500
1.5 yrs.
Conductivity/
TDS
718 µS/
503 ppm
6417-J
120
1.5 yrs.
Conductivity/
TDS
718 µS/
503 ppm
6417-L
500
1.5 yrs.
Conductivity/
TDS
718 µS/
503 ppm
6417-N
3800
1.5 yrs.
Conductivity/
TDS
1413 µS/
989 ppm
6354-J
120
Conductivity/
TDS
1413 µS/
989 ppm
6354-L
Conductivity/
TDS
1413 µS/
989 ppm
Conductivity/
TDS
pH
6.0
2876-L
500
1.5 yrs.
pH
6.86
2808-L
500
1.5 yrs.
pH Buffer
Tablets
7.0
3984A-H
50 Tabs
3 yrs.
pH Buffer
Tablets
7.0
3984A-J
100 Tabs
3 yrs.
pH
7.00
2881-H
60
1.5 yrs.
pH
7.00
2881-J
120
1.5 yrs.
pH
7.00
2881-L
500
1.5 yrs.
1.5 yrs.
pH
7.00
2881-N
3800
1.5 yrs.
500
1.5 yrs.
pH Color
Coded Yellow
7.00
3772-L
500
1.5 yrs.
6354-N
3800
1.5 yrs.
pH
8.0
2886-L
500
1.5 yrs.
pH
9.0
2891-L
500
1.5 yrs.
6668 µS/
4668 ppm
6418-J
100
1.5 yrs.
pH
9.18
2809-L
500
1.5 yrs.
10.0
3985A-H
50 Tabs
3 yrs.
Conductivity/
TDS
6668 µS/
4668 ppm
6418-L
500
1.5 yrs.
pH Buffer
Tablets
10.0
3985A-J
100 Tabs
3 yrs.
Conductivity/
TDS
12880 µS/
9016 ppm
6317-G
30
1.5 yrs.
pH Buffer
Tablets
pH
10.0
2896-J
120
1.5 yrs.
Conductivity/
TDS
12880 µS/
9016 ppm
6317-J
120
1.5 yrs.
pH
10.0
2896-L
500
1.5 yrs.
10.0
3773-L
500
1.5 yrs.
Conductivity/
TDS
12880 µS/
9016 ppm
6317-L
500
1.5 yrs.
pH Color
Coded Blue
pH
11.0
2897-L
500
1.5 yrs.
Conductivity/
TDS
58640 µS/
41048 ppm
6419-L
500
1.5 yrs.
pH
12.0
2898-L
500
1.5 yrs.
Copper
100 ppm
6181-L
475
2 yrs.
1000 ppm
6184-L
475
1 yr.
Fluoride
1000 ppm
4154-H
60
1 yr.
Phosphate
PO4
5393-H
60
2 yrs.
1000 ppm
4154-L
500
1 yr.
Phosphate
PO4
3080 ppm
Fluoride
Fluoride
1 ppm
2798-M
1000
2 yrs.
3080 ppm
5393-L
475
2 yrs.
Hard Water
120 ppm
5617-L
500
3 yrs.
Phosphate
PO4
Ferric Iron
200 ppm
3860-H
60
1.5 yrs.
1000 ppm
5393-H
60
2 yrs.
Magnesium
1000 ppm
6190-H
60
1 yr.
Phosphorus
(Total)
Nickel
1000 ppm
6196-H
60
2 yrs.
Phosphorus
(Total)
1000 ppm
5393-L
475
2 yrs.
Nitrate
Nitrogen
1000 ppm
5392-H
60
2 yrs.
Potassium
1000 ppm
6187-L
475
2 yrs.
continued next page...
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
93
Standards
Primary
Standards
Sodium
Chloride
94
Concentration
Order
Code
Quantity
(mL)
Shelf Life
4.0 ppt
6004-J
120
1.5 yrs.
Sulfate
2000 ppm
7120-H
60
2 yrs.
Turbidity
2020we
0 NTU
1480
60
1 yr.
Turbidity
2020we
1 NTU
1450
60
1 yr.
Turbidity
2020we
10 NTU
1451
60
1 yr.
Turbidity
2020we
100 NTU
1452
60
1 yr.
Turbidity
2020wi
0 NTU
1480
60
1 yr.
Turbidity
2020wi
1 NTU
1453
60
1 yr.
Turbidity
2020wi
10 NTU
1454
60
1 yr.
Turbidity
2020wi
100 NTU
1455
60
1 yr.
Turbidity
2020e
0 NTU
1480
60
1 yr.
Turbidity
2020e
1 NTU
1484
60
1 yr.
Turbidity
2020e
10 NTU
1485
60
1 yr.
Turbidity
2020e
100 NTU
1486
60
1 yr.
Turbidity
2020i
0 NTU
1480
60
1 yr.
Turbidity
2020i
1 NTU
1481
60
1 yr.
Turbidity
2020i
10 NTU
1482
60
1 yr.
Turbidity
2020i
100 NTU
1483
60
1 yr.
Turbidity
2020
1 NTU
1476
60
1 yr.
Turbidity
2020
10 NTU
1477
60
1 yr.
Turbidity
2020
100 NTU
1478
60
1 yr.
Turbidity
2020
250 NTU
1479
60
1 yr.
Primary
Standards
Concentration
Order
Code
Quantity
(mL)
Shelf Life
Turbidity
Formazin
4000 NTU
6195-H
60
1 yr.
Turbidity
ClearTrace
0 NTU
5-0116
1000
1 yr.
Turbidity
ClearTrace
1 NTU
5-0118
1000
1 yr.
Turbidity
ClearTrace
1 NTU
5-0119
3800
1 yr.
Turbidity
ClearTrace
10 NTU
5-0120
1000
1 yr.
Turbidity
ClearTrace
10 NTU
5-0121
3800
1 yr.
Turbidity
ClearTrace
20 NTU
5-0122
1000
1 yr.
Turbidity
ClearTrace
20 NTU
5-0123
3800
1 yr.
Zinc
100 ppm
5394-L
475
2 yrs.
Secondary
Standards
Concentration
Order
Code
Chlorine DPD
0, 0.2, 1.0,
2.5 ppm
4140-01
Smartcheck
Various
Absorbance
Units
4141
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Index
A
Absorbance Colorimeters. . . . . . . . . . . . . . . 21
Acidity
Individual Test Kits. . . . . . . . . . . . . . . . . 39, 61
Adapters,- AC
AC Power: 1200 Series. . . . . . . . . . . . . . . . . 19
AC Power: Battery Pack for
SMART Spectro. . . . . . . . . . . . . . . . . . . . . . 15
AC Power: pHPLUS Direct . . . . . . . . . . . . . . 30
Adapter, Vial
COD vial adapter. . . . . . . . . . . . . . . . . . . . . . . . 9
UDV vial adapter. . . . . . . . . . . . . . . . . . . . . . . . 9
Alkalinity
Buret Reagents. . . . . . . . . . . . . . . . . . . . . . . . 66
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 39
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
TesTabs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
UDV SMART Reagent. . . . . . . . . . . . . . . . . . . 17
Aluminum
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 39
SMART Reagent System. . . . . . . . . . . . . . . 17
AMCO Turbidity Standards . . . . . . . . . . 11, 13
Ammonia
ISE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ISE Accessory Kit. . . . . . . . . . . . . . . . . . . . . . 30
Ammonia Nitrogen
Colorimeter Kit, 1200. . . . . . . . . . . . . . 19, 40
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 40
SMART Reagent System. . . . . . . . . . . 17, 18
Apparatus
Alphabetical Listing. . . . . . . . . . . . . . . . 84-90
Aquaculture & Aquarium
Testing Products Catalog. . . . . . . . . . . . 91
Aquaculture Combination Outfits
Fresh Water. . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Salt Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Arsenic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Automatic Buret Reagents. . . . . . . . . . . . . . 66
B
BART Biodetectors. . . . . . . . . . . . . . . . . . . . . . 38
Battery Pack for SMART Spectro. . . . . . . . 15
Beakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Benzotriazole
SMART Reagent System. . . . . . . . . . . 17, 18
Biopaddles . . . . . . . . . . . . . . . . . . . . . . . . . 36-37
Biochemical Oxygen Demand (BOD)
BOD-Cubator. . . . . . . . . . . . . . . . . . . . . . . . . . 85
Bottle, cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Brush. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 40
PolySeed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Bleach
Individual Test Kits. . . . . . . . . . . . . . . . . 43, 62
Boron
SMART Reagent System. . . . . . . . . . . 17, 18
Bromine
Colorimeter Kit, 1200. . . . . . . . . . . . . . 19, 40
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 40
SMART Reagent System. . . . . . . . . . . 17, 18
Brushes
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Flask/BOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Imhoff Cone. . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Buffers
pH, Standardized. . . . . . . . . . . . . . . . . . . . . . 32
Color Coded Solutions . . . . . . . . . . . . . . . . . 32
Tablets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Buret Combination Kits. . . . . . . . . . . . . . . . . 65
Buret Reagents. . . . . . . . . . . . . . . . . . . . . . . . . 66
Burets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
C
Cadmium
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 41
SMART Reagent System. . . . . . . . . . . 17 ,18
Calcium Hardness
See Hardness
Carbon Dioxide
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 41
Carbohydrazide
SMART Reagent System. . . . . . . . . . . 17, 18
Cases
SMART Spectro. . . . . . . . . . . . . . . . . . . . . . . . 15
Catalogs, Market Specific. . . . . . . . . . . . . . . 91
Caustic
Individual Test Kits. . . . . . . . . . . . . . . . . 41, 61
Chelant
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 41
Chemistry and Control of Modern
Chlorination Handbook. . . . . . . . . . . . . . . . 92
Chloride
Buret Reagents. . . . . . . . . . . . . . . . . . . . . . . . 66
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 41
SMART Reagent System. . . . . . . . . . . 17, 18
Chlorine
Colorimeter Kit, Liquid, 1200. . . . . . . 20, 42
Colorimeter Kit, Tablet, 1200. . . . . . . 20, 42
Individual Test Kits. . . . . . . . . . . . . . . . . 42, 61
Secondary Standards Kit. . . . . . . . . . . . . . . 21
Primary Standards. . . . . . . . . . . . . . . . . . . . . 21
Reagents. . . . . . . . . . . . . . . . . . . . . . . . . . 17, 72
SMART Reagent System. . . . . . . . . . . 17, 18
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Tracer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .43, 61
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . 34, 61
TesTabs for Tracer. . . . . . . . . . . . . . . . . . . . . 22
Tri-Meters. . . . . . . . . . . . . . . . . . . . . . . . . 12, 13
Chlorine Dioxide
Colorimeter Kit, 1200. . . . . . . . . . . . . . 19, 20
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 44
SMART Reagent System. . . . . . . . . . . 17, 18
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Chromate
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 44
Chromium
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 44
SMART Reagent System. . . . . . . . . . . 17, 18
Cleaners
Alconox®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Kimwipes®. . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Cobalt
SMART Reagent Systems. . . . . . . . . . 17, 18
COD
Adapter for SMART Colorimeter. . . . . . . . . . 9
Heater Blocks . . . . . . . . . . . . . . . . . . . . . 16, 86
SMART Reagent System. . . . . . . . . . . 17, 18
Reagents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Coliform
Filter Flasks. . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Filter Paper. . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 38
Sample Bags. . . . . . . . . . . . . . . . . . . . . . . . . . 86
Sample Vials . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Color
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 44
SMART Reagent System. . . . . . . . . . . 17, 18
LTC-3000. . . . . . . . . . . . . . . . . . . . . . . . . 12, 13
Tri-Meters. . . . . . . . . . . . . . . . . . . . . . . . . 12, 13
ColorQ Colorimeter . . . . . . . . . . . . . . . . . . . . . 71
ColorQ Pro-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Colorimeter
Single Test. . . . . . . . . . . . . . . . . . . . . . . . 19, 20
Single Test Accessories. . . . . . . . . . . . 19, 20
Single Wavelength Absorbance. . . . . . . . . 21
SMART3 Colorimeter. . . . . . . . . . . . . . . . . . 8, 9
UDV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Colorimeter Series, DC1200. . . . . . . . 19, 20
Colorimetric Test Method. . . . . . . . . . . . . 6
Combination Buret Outfits. . . . . . . . . . . . . . 65
Conductivity
5 and 6 Series Meters. . . . . . . . . . . . . . . . . . 29
PockeTesters. . . . . . . . . . . . . . . . . . . . . . 23, 26
Standards. . . . . . . . . . . . . . . . . . . . . . . . . 23, 33
Neutralizing Solutions . . . . . . . . . . . . . . . . . 33
Tracer Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . 23
95
Index
Copper
Colorimeter Kit, DC1200 . . . . . . . . . . . 20, 45
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 45
SMART Reagent System. . . . . . . . . . . 17, 18
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . 34-35
Corrosion Control Kit. . . . . . . . . . . . . . . . . . . . 74
Custom Test Kit Services. . . . . . . . . . . . . . . . . 5
Cyanide
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 45
SMART Reagent System. . . . . . . . . . . 17, 18
Cyanuric Acid
SMART Reagent System. . . . . . . . . . . 17, 18
Tablets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Cylinders. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
D
DC1200
Colorimeter Series. . . . . . . . . . . . . . . . . 19, 20
DEHA
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 45
SMART Reagent System. . . . . . . . . . . 17, 18
DO Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Detergents
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 45
DipCell Series. . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Direct Reading Titrator
Combination Outfits. . . . . . . . . . . . . . . 67-68
Test Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dissolved Oxygen
See Oxygen
Duo-Soft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
DPD Reagents
Liquids. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 72
Powder-Pop Dispensers . . . . . . . . . . . . . . . 20
TesTabs. . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 72
Dropper Bottle. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combination Outfits. . . . . . . . . . . . . . . 67-68
Test Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dropper Pipet
Test Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
E
Electrode Soaker Bottle. . . . . . . . . . . . . . . . . 32
Electrodes for PockeTesters. . . . . . . . 22-27
Environmental Science
Education Catalog. . . . . . . . . . . . . . . . . . . . . 91
Environmental Science Education
Combination Outfits. . . . . . . . . . . . . . . 57-60
Erythorbic Acid
SMART Reagent System. . . . . . . . . . . 17, 18
96
F
Filter Papers
General Lab . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Filter/Syringe Assembly. . . . . . . . . . . . . . . . . 87
5 and 6 Series Meters. . . . . . . . . . . . . . . . . . . 29
Flasks
Brush. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Erlenmeyer. . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Filter Flasks. . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Volumetric . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Fluoride
Colorimeter Kit, DC1200 . . . . . . . . . . . 20, 45
ISE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ISE Accessory Kit. . . . . . . . . . . . . . . . . . . . . . 30
SMART Reagent System. . . . . . . . . . . 17, 18
Food Sanitizer Kits. . . . . . . . . . . . . . . . . . . . . . 61
Formaldehyde
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 45
Fresh Water Aquaculture
Combination Outfits. . . . . . . . . . . . . . . . . . 56
Funnels, Plastic. . . . . . . . . . . . . . . . . . . . . . . . . 88
G
General Water Analysis
Combination Outfit. . . . . . . . . . . . . . . 63-64
Gluteraldehyde
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 45
Graduated Cylinders. . . . . . . . . . . . . . . . . . . . 87
GREEN
Low-Cost Water
Monitoring Kit. . . . . . . . . . . . . . . . . . . . . . . . 60
H
Handbooks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Hardness
Buret Reagents. . . . . . . . . . . . . . . . . . . . . . . . 66
Calcium Hardness TesTabs. . . . . . . . . . . . . 72
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 46
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . 34-35
Hydrazine
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 46
SMART Reagent System. . . . . . . . . . . 17, 18
Hydrogen Peroxide
Individual Test Kits. . . . . . . . . . . . . . . . . 47, 50
SMART Reagent System. . . . . . . . . . . 17, 18
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Hydrometers
Cylinder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Specific Gravity. . . . . . . . . . . . . . . . . . . . . . . . 88
Hydroquinone
SMART Reagent System. . . . . . . . . . . 17, 18
I
International Sales. . . . . . . . . . . . . . . . . . . . . . . 5
Iodine
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 47
SMART Reagent System. . . . . . . . . . . 17, 18
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .47, 61
Ion Specific Electrode
Accessory Kits. . . . . . . . . . . . . . . . . . . . . . . . . 30
pH Plus Direct Meter. . . . . . . . . . . . . . . . . . . 30
Probes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Tracer Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Individual Test Kits
By Test Factor. . . . . . . . . . . . . . . . . . . . . 39-55
Industrial Titration Reagents. . . . . . . . . . . . 66
Industrial Water
Combination Outfits. . . . . . . . . . . . . . . 65-68
Insta-Test® Strips . . . . . . . . . . . . . . 34, 35, 69
Instrumentation. . . . . . . . . . . . . . . . . . . . . 8-33
Investigating Water Problems
Handbook. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Iron
Colorimeter Kit, DC1200 . . . . . . . . . . . . . . . 20
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 47
SMART Reagent System. . . . . . . . . . . 17 ,18
K
Kick-Net. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Kimwipes®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
L
A Laboratory Manual for Marine
Science Studies Handbook. . . . . . . . . . . . 92
The LaMotte Soil Handbook. . . . . . . . . . . . . 92
Laundry Combination Outfits . . . . . . . . . . . 62
Laundry Spot Tests. . . . . . . . . . . . . . . . . . . . . 62
Lead
SMART Reagent System. . . . . . . . . . . 17, 18
Lead in Solder
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 47
Leaf Pack Stream Ecology Kit. . . . . . . . . . . 57
Limnology: An Introduction to the
Fresh Water Environment Handbook. . . 92
Limnology Combination Outfit. . . . . . . . . . 58
Lignin
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 55
LTC-3000we/wi. . . . . . . . . . . . . . . . . . . . . 12, 13
Lubriseal®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Index
M
Manganese
Colorimeter Kit, DC1200 . . . . . . . . . . . 19, 20
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 48
SMART Reagent System. . . . . . . . . . . 17, 18
Magnetic Stirrers. . . . . . . . . . . . . . . . . . . . . . . 89
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Marine Aquarium Handbook. . . . . . . . . . . . 92
Marine Science Outfit. . . . . . . . . . . . . . . . . . . 58
Mercury
SMART Reagent System. . . . . . . . . . . 17, 18
Methods, Test. . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Methylene Bisthiocyanate. . . . . . . . . . . . . . . 48
Methylethylketoxime
SMART Reagent System. . . . . . . . . . . 17, 18
Microbiological Tests . . . . . . . . . . . . . . . 36-38
Min/Max Thermometer . . . . . . . . . . . . . . . . . 25
Molybdate/Molybdenum
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 48
Colorimeter Kit, DC1200 . . . . . . . . . . . 19, 48
SMART Reagent System. . . . . . . . . . . 17, 18
Monitor’s Handbook. . . . . . . . . . . . . . . . . . . . 92
MPS-OUT TesTabs. . . . . . . . . . . . . . . . . . . . . . 72
N
Nickel
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 48
SMART Reagent System. . . . . . . . . . . 17, 18
Nitrate Nitrogen
Colorimeter Kit, DC1200 . . . . . . . . . . . 19, 49
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 49
ISE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ISE Accessory Kit. . . . . . . . . . . . . . . . . . . . . . 30
SMART Reagent System. . . . . . . . . . . 17, 18
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Nitrite Nitrogen
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 49
SMART Reagent System. . . . . . . . . . . 17, 18
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Nitrite, Sodium
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 49
Nitrogen, Total Digestion Tubes. . . . . 16, 18
O
ORP PockeTester . . . . . . . . . . . . . . . . . . . . . . . 25
ORP Tracer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Our Environment Battles Water
Pollution Handbook. . . . . . . . . . . . . . . . . . 92
Oxygen, Dissolved
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 50
SMART Reagent System. . . . . . . . . . . 17, 18
Tracer Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Oxygen Scavenger
SMART Reagent Systems. . . . . . . . . . 17, 18
Ozone
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 50
SMART Reagent System. . . . . . . . . . . 17, 18
Colorimeter Kit, DC1200 . . . . . . . . . . . 19, 50
P
Peracetic Acid
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 50
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . 34, 50
Peroxide
See Hydrogen Peroxide
pH
5 Series pH Meter. . . . . . . . . . . . . . . . . . . . . . 29
Buffers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Electrodes for pHPLUS Meter . . . . . . . . . . 30
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 51
Electrode Soaker Bottle. . . . . . . . . . . . . . . . 32
Meters. . . . . . . . . . . . . . . . . 22, 23, 25, 29, 30
pHPLUS Direct Meter. . . . . . . . . . . . . . . . . . 30
PockeTesters. . . . . . . . . . . . . . . . . . 22, 23, 25
SMART Reagent System. . . . . . . . . . . 17, 18
Tablets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .50, 61
Test Strips. . . . . . . . . . . . . . . . . . . . . 34, 35, 69
Tracer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
pH/Conductivity
Tracer Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . 23
pH, Buffers & Acid/Base Titrations
Handbook. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Phenols
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 50
SMART Reagent System. . . . . . . . . . . 17, 18
Phosphate
Colorimeter Kit, DC1200 . . . . . . . . . . . 19, 52
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 52
SMART Reagent System. . . . . . . . . . . 17, 18
Phosphonate
Individual Test Kits. . . . . . . . . . . . . . . . . 52-53
Phosphorus, Digestion Tubes. . . . . . . 16, 18
Pipets
Safety Bulb. . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Plankton Net . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Plant Nutrition Studies Handbook. . . . . . . 92
PockeTesters. . . . . . . . . . . . . . . . . . . . . . . 22-27
Electrodes. . . . . . . . . . . . . . . . . . . . . . . . . 22-27
Polyphosphates
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 53
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Polyquat
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 53
Pool & Spa Combination Outfits. . . . . 70-72
Pool & Spa Testing
Equipment Catalog. . . . . . . . . . . . . . . . . . . . 91
Pool MGR. Handbook. . . . . . . . . . . . . . . . . . . . 92
Pool MGR. Series Kits. . . . . . . . . . . . . . . . . . . 70
Potassium
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 53
SMART Reagent System. . . . . . . . . . . 17, 18
Powder Pop DPD Dispensers
For Free & Total Chlorine. . . . . . . . . . . . . . . 20
PRO250 Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Product Price List. . . . . . . . . . . . . . . . . . . . . . . 91
Q
QAC
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 53
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .53, 61
R
Reagent Refills . . . . . . . . . . . . . . . . . . . . . 76-83
RS-232 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . 19
S
Safety Bulb
Pipet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Salinity
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 53
Salt Water Aquaculture
Combination Outfit. . . . . . . . . . . . . . . . . . . 56
Salt Water PockeTesters. . . . . . . . . . . . 23, 26
Salt Water Test Strips. . . . . . . . . . . . . . . 34, 69
Sample Bags
Coliform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Secchi Disk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Silica
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 54
SMART Reagent System. . . . . . . . . . . 17, 18
Single Test Colorimeters. . . . . . . . . . . . 19, 20
SMART3 Colorimeter
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8, 9
SMART Reagent Systems. . . . . . . . . . 17, 18
Water Analysis Lab. . . . . . . . . . . . . . . . . 63-64
SMART Spectro Spectrophotometer
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Instrument. . . . . . . . . . . . . . . . . . . . . . . . 14, 15
Reagent Systems. . . . . . . . . . . . . . . . . . 17, 18
SMARTLink 3 Software and cable. . . . . . . . 9
®
97
Index
Sodium Chloride
Test Strips. . . . . . . . . . . . . . . . . . . . . . . . . 34, 69
PockeTesters. . . . . . . . . . . . . . . . . . . . . . 23-27
Sodium Nitrite
See Nitrite
Softeners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Softener Sales Demo Kits. . . . . . . . . . . . . . . 75
Soil Testing Products Catalog. . . . . . . . . . . 91
Spa/Pool Combination Outfits . . . . . . 70-71
Standards
Full Listing . . . . . . . . . . . . . . . . . . . . . . . . 93, 94
Chlorine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Turbidity. . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 13
TDS/Conductivity. . . . . . . . . . . . . . . . . . 23, 33
Stir Bars. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Retrievers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Stirrers
Magnetic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Stopcock Grease
Lubriseal®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Storm Drain Kit. . . . . . . . . . . . . . . . . . . . . . . . . 74
A Study of Soil Science
Handbook. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
A Study of Water Quality
Handbook. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Sulfate
Colorimeter Kit, DC1200 . . . . . . . . . . . . . . . 19
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 54
Sulfate Interference Suppresor Kit. . . . . . 52
Sulfate
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 54
SMART Reagent System. . . . . . . . . . . 17, 18
Sulfide
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 54
SMART Reagent System. . . . . . . . . . . 17, 18
Sulfite
Buret Reagents. . . . . . . . . . . . . . . . . . . . . . . . 66
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 55
Surfactants
SMART Reagent System. . . . . . . . . . . 17, 18
T
Tannin
Individual Test Kit. . . . . . . . . . . . . . . . . . . . . . 55
SMART Reagent System. . . . . . . . . . . 17, 18
Temperature
Min/Max PockeTester. . . . . . . . . . . . . . . . . . 25
Probe, pHPLUS Direct. . . . . . . . . . . . . . . . . . 30
Temptestr IR . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Test Methods. . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
98
Test Papers
pH, Chlorine, Iodine, QAC. . . . . . . . . . . . . . . 61
Test Strips
Alkalinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Hardness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Insta-Test Pool/Spa Series. . . . . . . . . . . . . 69
pH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Hydrogen Peroxide. . . . . . . . . . . . . . . . . . . . 34
Multi-factor. . . . . . . . . . . . . . . . . . . . . . . 35, 69
Single Factor. . . . . . . . . . . . . . . . . . . . . . . . . . 34
Sodium Chloride. . . . . . . . . . . . . . . . . . . 34, 69
TesTabs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 72
Thermometers
Armoured Thermometer. . . . . . . . . . . . . . . 90
Dual Scale. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Min/Max PockeTester. . . . . . . . . . . . . . . . . . 25
Switchable. . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Temptestr IR . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Titrimetric Methods. . . . . . . . . . . . . . . . . . . . . . 7
Tolcide PS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Tolyltriazole
SMART Reagent System. . . . . . . . . . . 17, 18
Total Dissolved Solids (TDS)
6 Series Meters. . . . . . . . . . . . . . . . . . . . . . . . 29
PockeTesters. . . . . . . . . . . . . . . . . . . . . . 22, 27
Standards. . . . . . . . . . . . . . . . . . . . . . . . . 23, 33
Tracer Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Tour Series
Pondwater Tour. . . . . . . . . . . . . . . . . . . . . . . . 59
Shore Tour . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Tapwater Tour. . . . . . . . . . . . . . . . . . . . . . . . . 59
Topsoil Tour . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Watershed Tour. . . . . . . . . . . . . . . . . . . . . . . . 59
Tracer Meter Series. . . . . . . . . . . . . . . . . 22-24
Accessories. . . . . . . . . . . . . . . . . . . . . . . 22-24
Chlorine, pH, ORP. . . . . . . . . . . . . . . . . . . . . . 22
Dissolved Oxygen. . . . . . . . . . . . . . . . . . . . . . 24
pH/Conductivity. . . . . . . . . . . . . . . . . . . . . . . 23
TDS/Salt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Transfer Pipets. . . . . . . . . . . . . . . . . . . . . . . . . 89
Turbidity
Turbidity Accessories . . . . . . . . . . . . . . 11, 13
Turbidity Standards. . . . . . . . . . . . . . . . 11, 13
Turbidity Meters
2020we. . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 11
2020wi. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 11
LTC-3000we/wi. . . . . . . . . . . . . . . . . . . . 12, 13
Turbidity: Its Meaning &
Measurement Handbook. . . . . . . . . . . . . . 92
U
UDV
Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Colorimeters . . . . . . . . . . . . . . . . . . . . . . . . . . 21
V
Vials
Sampling, Coliform . . . . . . . . . . . . . . . . . . . . 86
W
Wastewater Lab. . . . . . . . . . . . . . . . . . . . . . . . 73
Water & Wastewater
Combination Outfits. . . . . . . . . . . . . . . . . . . 74
Water Conditioning
Combination Outfits. . . . . . . . . . . . . . . . . . . 75
Water Conditioning
Testing Equipment Catalog. . . . . . . . . . . . 91
Water Quality Educator
Monitoring Outfit. . . . . . . . . . . . . . . . . . . . . . 57
Water Quality Combination Outfits. . . . . . 75
WaterLink® Spin. . . . . . . . . . . . . . . . . . . . . . . . 68
Weighted Stand for Tracer. . . . . . . . . . . . . . 22
Wide Range pH. . . . . . . . . . . . . . . . . 34, 35, 50
Z
Zinc
Individual Test Kits. . . . . . . . . . . . . . . . . . . . . 55
SMART Reagent System. . . . . . . . . . . 17, 18
LaMOTTE COMPANY 800.344.3100 or 410.778.3100 www.lamotte.com
Order Form
How To Order
By Mail: LaMotte Company
PO Box 329
Chestertown, Maryland 21620 USA
Bill To
Name
Title
Company
Department
City
State/Zip
Phone
Account #
By Phone: 800 344 3100
410 778 3100
By Fax: 410 778 6394
Website:www.lamotte.com
Ship To
Name
Title
Company
Department
City
State/Zip
Phone
Ship Via.
Special Instructions:
Payment Method
Payment Terms are net 30 days to accounts with established credit. New accounts should provide credit references or enclose payment with order. MasterCard, VISA, and American Express are also accepted.
‰‰ Check
Credit Card Account #
‰‰ Purchase Order
Expiration Date
‰‰ MasterCard
Purchase Order #
‰‰ VISA
‰‰ American Express
Name as it appears on card
Order
Please include the product code number for each item ordered to insure that your order is speedily and correctly processed.
Prices are f.o.b., Chestertown, Maryland. Prices are subject to change without prior notice. A $7.50 handling fee and a $7.50
shipping fee are applied to all orders totaling less than $35.00. On orders to which handling fee is not applicable, freight
charges at cost will be added to invoice total.
Quantity
Code
Model/Description
Unit Price
Extension
Net Total
$15.00 Shipping and Handling Fee (If Net Total is Less Than $35.00)
Sales Tax, If Applicable (Maryland Only)
Invoice Total
PHONE
1-800-344-3100
(001) 1-410-778-3100
FAX
(001) 1-410-778-6394
INTERNET
www.lamotte.com
http://lamotte.com/contact_us.html
MAIL
PO Box 329
802 Washington Avenue
Chestertown, Maryland 21620 USA
EASY PAYMENT
Order with a purchase order or use VISA, American Express,
MasterCard or enclose payment with purchase order if
you don’t have an account. To open a new account, please
provide credit references.
COURTEOUS SERVICE and an interest in every customer’s satisfaction have given
LaMotte Company a reputation of distinction in the chemical testing field. Please
give us the opportunity to meet your chemical testing requirements today.
Download PDF
Similar pages