Benchtop Water hardness meter LBWM-A10_front

BENCHTOP WATER
HARDNESS METER
LBWM-A10
www.labtron.com
info@labtron.com
Benchtop Water hardness meter LBWM-A10
Benchtop Water hardness meter LBWM-A10 is equipped with large backlit LCD display, 2 to
5 points calibration with low to high concentration range. The calibration due reminder
alerts user for calibration of the meter on regular basis. The System menu allows setting the
7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other
elements at mg/L, mmol/ scale which causes hardness water.
Features
Large LCD display
Two to five points calibration with low to high range
System menu with 7 parameters setting
Stability indicator to robotically display current measurements
Automatic electrode diagnosis shows the slope of sensor
Calibration due reminder for regular calibration of the meter
Manual temperature compensation for better measurement accuracy of meter
Auto hold function freezes stable, final readings for better viewing and recording
Automatic temperature compensation for accurate measured value over the entire
range
Reset function
Enlarged memory can store up to 500 sets of data
Built-in real time clock stamps
Operational guide for Quick access to the conductivity meter
Applications
Benchtop water hardness meter is used in testing the hardness level of tap water, drinking
water, filtered water, water used for different experiments and testing across food, textile,
painting & other industries.
Specifications
LBWM-A10
Model no
Water hardness range
0.05mmol/L-0.2mol/L
(CaCO3) 0-19999mg/L, (CaO) 0-11220mg/L,
(boiler) 0-400mmol/L, (Ca) 0-8020mg/L
(German degree) 0-11220dH, (English degree)
0-14040e, (French degree) 0-20000f
Accuracy
±1%F.S.
Calibration points
2 to 5 points
Calibration solution
0.001, 0.01, 0.1mmol/L, 0.001, 0.01, 0.1mol/L
Temperature range
0 to 1050C
Temperature accuracy
±0.50C
Calibration range
Measured value ±100C
Temperature compensation range
0-500C
Compensation mode
Manual or automatic
Data hold function
Manual or automatic endpoint detection
Reset function
Yes
Stability condition
Low or high
Calibration due
0 to 31 days
Memory
Stores up to 500 sets of data
Output
USB communication interface
Connector
BNC
Battery life
Approximately 150 hours
Power
3*1.5V “AA” batteries
Dimension (L*W*H)
210×180×60 mm
Weight
1.5 kg
Standard accessories
• Water hardness electrode
• Temperature probe
• AA batteries
• Carrying case
Optional accessories
• Water hardness electrode range 0.00005 to 0.2M
Download PDF