W & M SERIES: IDH MAX® & ELECTROMECHANICAL LOCKS
W & M Series
IDH MAX® & Electromechanical Locks
BEST: Setting the Standard for Security
TABLE OF CONTENTS
IDH MAX® introduction ..........................................................2
IDH MAX® features...............................................................2-3
IDH Max® and IDH Max® 1300 comparison chart................3
HM, KM, HW & KW options...................................................3
40HM IDH MAX® specifications, how-to-order...................4
40HM IDH MAX® functions.....................................................5
93KM IDH MAX® specifications, how-to-order....................6
Quick Connect, how-to-order...........................................7, 20
93KM IDH MAX® functions.....................................................7
40HW/8KW/9KW electrified lock introduction....................7
40HW electrified specification................................................7
40HW electrified functions..................................................8-9
40HW electrified how-to-order..............................................8
8KW/9KW electrified specification......................................10
8KW/9KW elec­tri­fied how-to-order ...................................10
8KW/9KW electrified functions............................................10
Trim variations........................................................................11
Electrified accessories.......................................................12,13
Terminology............................................................................13
1W electric switch lock introduction...................................14
Optional boxes.......................................................................14
1W electric switch lock how-to-order ................................14
1W electric switch locks................................................... 15-19
IDH MAX® – Introduction
The IDH MAX® from BEST offers convenience and efficiency for your electrified lock applications. Instead of installing reader devices,
installing electrified strikes, installing door contacts and installing request-to-exit devices, you can now install the IDH MAX® in cylindrical or
mortise lock applications. With IDH MAX® all of the formerly separate equipment needed to control access are self-contained in a single
installation. The complexity of multiple wire runs is drastically reduced.
You can let BEST show you how to MAXimize your access control system with the IDH MAX®! For the name and location of your local
office, visit our web site at www.bestaccess.com. IDH MAX® and W series locks are compatible with BEST's NT500, Mercury and most
other Access Control Systems. The IDH Max® 1300 option will only work with the Mercury system and only on electrically unlocked “EU”
functions.
IDH MAX® – Features
IDH Max® Features
Includes latch status, door status and request to exit features
NOTE: Latch Status not available on Deadbolt functions
• The 1300 option eliminates the need for a PIM
(Panel Interface Module)
• Requires only one 4 conductor wire run
• Reduces number of components installed and visible at the door
(PIR, RQE push buttons and door contacts)
• Installation time is reduced
• The RQE switch senses the inside lever/knob rotation
• All of the door components are housed in one manufacturer’s
hardware
• With the elimination of components, only the lockset is visible at
the door
• The reader is integrated into the lockset escutcheon
• Available in magnetic stripe and proximity readers
• Available in all popular lever/knob styles and finishes
• Operates with BEST interchangeable core as a mechanical
override
• Integrates with many manufacturer’s on-line EAC equipment
Mortise Features
• Lock case meets the requirements as listed in the ANSI/BHMA
A156.13 standard for Series 1000, Grade 1 Operational and
Grade 2 Security locks
• UL listed for GYQS Electrically controlled single point locks or
latches for use on 3 hr, A label doors (4’ x 10’). The listing applies
for both U.S. and Canadian applications
2
W & M Series IDH MAX® & Electromechanical Locks
• Door contact, request-to-exit, and latch status sensors positioned
inside lock case
• The door contact magnet is installed behind the strike and out
of site (except when deadbolt option is ordered)
• All sensors are standard in IDH Max mortise locks
• The heavy duty design of the mortise lock results in less field
maintenance and part failures
• Twist off lever spindle design protect internal lock parts from
damage and failure.
• Oil impregnated stainless steel 3/4” anti-friction latchbolt
reduces door closing force and wear.
Cylindrical Features
• Non-handed levers allow for ease of installation
• Lock chassis meets the requirements as listed in the ANSI/BHMA A156.2, standard for Series 4000 Grade 1 locks
• UL listed for GYQS Electrically controlled single point licks or
latches for use on 3 hr, A label single doors (4’ x 10’) GYJB. The
listing applies for both U.S. and Canadian applications
• Request-to-exit sensor positioned inside lock trim
• The ISC (Intelligent System Controller) is embedded behind the
escutcheon secured and out of site
• Request-to-exit and door contact sensors are standard in IDH
MAX cylindrical locks
Magnetic Stripe Electronic Lock Features
• Durable material has teflon-like characteristics for increased life and wear resistance
• Variable read rate allows for easy usage
Proximity Card Reader Features
• HID and Motorola/Indala proximity cards supported
• Usable in most environmental/exterior applications.
1300 Option Features
• Eliminates need for small panel interface module
• Eliminates reader interface board
• Incorporates 3 modules into a single electronics board inside IDH
Max escutcheon trim
• Connects directly to ACP via 2 wire RS485 connection
IDH MAX® & IDH MAX® 1300 Comparison Chart
IDH MAX®
• Prep door for IDH MAX®
• Run single 4 conductor wire
for IDH MAX®
• Install IDH MAX®
• Install electrified hinge
• Mount PIM
IDH MAX® 1300
• Prep door for IDH MAX®
• Run single 4 conductor wire
for IDH MAX® 1300
• Install IDH MAX® 1300 which
includes Intelligent System
• Install electrified hinge
** Operates with Mercury control
panels only.
* Operates with most control panel
hardware, Mercury control panels.
IDH MAX®
IDH MAX® 1300
HM, KM, HW & KW – Options
AL – Besides complying with a wide variety of accessibility codes and ordinances, lever handles are available with a special abrasive feature. Abrasive strip on the lever im­me­di­ate­ly identifies warnings on doors to hazardous areas for the blind.
BRK – When excessive force (approx. 300 inch lbs.) is applied to #4, #6 keyed knobs, they “breakaway” and spin freely, thus allowing
entrance only by key. Simple part replacement returns lock to func­tion­al usage.
C – The easy to use quick connect system enables efficient installation to the respective BEST Lock electrical options ordered.
IDH – The Integrated Door Hardware groups three components into one hardware package. 1. Door status switch (normally closed)
2. Request-to-Exit switch (normally open) 3. Electrically controlled locking mechanism.
KNL – Knurl feature is available only on #6 knobs. The knurling is machined into the outer edge of the knob. The knurled feature can be
used for blind, safe­ty, or ac­ces­si­bil­i­ty applications.
LL – Lead lined feature can be used to protect against X-rays. Since the majority of lead lined doors contain the lead in the surface of the
door, the knob lockset provide lead lining for the holes cut in the door when preparing the door for the trim.
LM – The Lost Motion feature allows the lever handle to turn freely when it is locked without retracting the latchbolt assembly.
This feature makes over-torque abuse more difficult to achieve.
SH – Security head provided for all exposed screws.
RQE – Cylindrical or Mortise locksets can be supplied with a request-to-exit switch. A normally open switch provides momentary switch
closure when the inside lever/knob is rotated.
TAC – Grooves are machined into knobs to improve grip or to be used as a warning in hazardous areas. This option can be used for blind,
safety or ac­ces­si­bil­i­ty applications.
Thick door – Specify thickness if other than 1 3⁄4” .
TL – Tactile levers may be used in areas where improved grip is required or as a warning in hazardous or Safety First areas. Grooves are machined into the back of the hand grasp portion of the lever to improve grip and/or provide a sensory warning. This option can be used
for blind, safety, or accessibility applications.
1300 – Integrated BAS1300/LNL1300 reader electronics board or (ISC) Intelligent System Controller is embedded behind the escutcheon
secured and out of site. Functions with Mercury on-line equipment only.
NOTE: 1300 option not available on any “EL” electrically locked functions.
W & M Series IDH MAX® & Electromechanical Locks
3
40HM IDH Max® – Specifications
Mechanical
Case – Heavy wrought steel, 5 7⁄8” H x 4 1⁄4” D x 1” W steel parts are zinc dichromate plated for cor­ro­sion pro­tec­tion.
Faceplate – Brass or bronze, 8” H x 1 1⁄4” W x 1/16” T . Lock face automatically adjusts to proper bevel during installation.
Strike – Brass, bronze or stainless steel base material, 4 7⁄8” H x 1 1⁄4” W x 3⁄32” T. Fits standard
door frame cut out as specified in ANSI A115.1. Universal (non-handed) strike supplied standard with lock.
Backset – 2 3/4”
Door thickness – For doors 1 3⁄4” – 3” thick. (specify thickness when ordering)
Installation – Lock requires modified door prep to mount the trim. Faceplate di­men­sions fit stan­dard door prep­a­ra­tion
as specified in ANSI A115.1,. Lockset is easily reversible to match door handing without opening the mortise case.
45HM IDH MAX
Latchbolt – Solid stainless steel, 3/4” throw. Latch is oil-impregnated for anti-friction operation. Reversible without
Mortise
opening case.
Deadbolt – Solid stainless steel, 1” throw.
Auxiliary bolt – Stainless steel, non-handed.
Escutcheons – 10 1/2” H x 3 5/16” W x 1” D (1” at the top, sloping down to 3/4” at the bottom)
Knobs – Diameter: 2 1⁄8” Projection on door: 2 7⁄8” #4, #6 knobs: Material machined from brass or bronze.
Lever handle – Brass, bronze or stainless steel. (Lever #3, #14 and #15 conform to California Titles 19 and 24.)
Mounting – Knob and lever attached with hardened set screw on inside knob or inside lever.
Finish –
• 605-bright brass, clear coated
• 612-satin bronze, clear coated
• 625-bright chromium plated
• 630-satin stainless steel
• 606-satin brass, clear coated
• 613-oxidized satin bronze, oil
• 626*-satin chromium plated
• 690**-dark bronze.
rubbed
• 611-bright bronze, clear coated
• 629-bright stainless steel
®
* 613 finish is designed to wear over time, providing an “antique” appearance. ** 690 finish will continue as a dark brown appearance over time.
Antimicrobial Finishes –
• 626AM – Satin Chrome Plated with UltraShield Antimicrobial coating
• 630AM – Satin Stainless Steel with UltraShield Antimicrobial coating
Electronic
Maximum current draw: 1.1 Amp for 50 milliseconds. Typical current draw (hold condition): 650 milliAmps Voltage: 10.2 to 13.2 V (DC only)
Magnetic Stripe Card Reader
Read Rate – 5 inches per second to 50 inches per second.
Card Thickness – ISO standard .030” ± .003 thick. Compliance to FCC, Canadian, and European EMC requirements; for interference
FCC Class A digital apparatus.
Proximity Reader – ANSI/BHMA A156.25 compliant. Compatible with Motorola / Indala and HID proximity cards. ABA and Wiegand
output. Weatherproof bezel and gasket provide protection for outdoor use. (Usable in most environmental/exterior applications)
Card Read Range – 0 – 3 inches. Compliance to US FCC, Canadian FCC, and European EMC requirements
ESD Protection – 15 Kilo Volt
40HM IDH MAX® – How To Order
45HM
7
DEU
Series
Core
Function
Housing
45HM–
IDH
Max™
Mortise
0– Keyless or
less cylinder,
7– 7 pin
IC housing
accepts all
BEST cores
14
MS
626
RH
Lever/Knob Trim Style *
Style
Finishes
Handing Options
DEL– single key latch, fail safe
DEU– single key latch, fail
secure
NXEL– keyless, latch, fail safe
NXEU– keyless, latch, fail secure
TDEL– single key deadbolt,
fail safe
TDEU– single key deadbolt, fail
secure
LEL– keyless, deadbolt, fail safe
LEU– keyless, deadbolt, fail
secure
Levers
14– curved
return
15– curved
angle return
16– curved no
return
17– gullwing
no return
Knobs
4– round
MS–magnetic
stripe
PM–proximity
Motorola
PH– proximity HID
MSA– other cylinder
PHA– other cylinder
PMA– other cylinder
605 606 611 612
613 618 619 625
626 690
Antimicrobial Finishes
626AM – Satin Chrome
Plated with UltraShield
Antimicrobial coating
630AM – Satin Stainless
Steel with UltraShield
Antimicrobial coating
RH
RHRB
LH
LHRB
(page 5)
(page 11)
(page 11)
*Standard readers use BEST concealed cylinder; Adaptation trim can accept other manufacturers cylinders.
**1300 option not available on any “EL” electrically locked functions.
4
W & M Series IDH MAX® & Electromechanical Locks
KNL
C – quick connect
SH – se­cu­ri­ty head
screws
TAC – tactile lever
Thick Door –
specify thick­ness if
other than 1 3/4”
7/8” LTC– flat lip
strike
1300** – Mercury
direct connect
40HM IDH Max® – Functions
Function
DEL–Locked
Fail Safe
DEU–Unlocked
Fail Secure
NXEL–Locked
Fail Safe
Latch
Outside Knob/Lever
Inside Knob/Lever
Operated by
Locked by
Unlocked by
Locked by
Unlocked by
• Outside knob/lever when power is
removed from the solenoid
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Applying power to the
solenoid; remains locked
while power is on.
Removing power from the solenoid
Cannot be locked
Always unlocked
Applying power to the solenoid;
remains unlocked while power is on.
Cannot be locked
Always unlocked
Removing power from the solenoid
Cannot be locked
Always unlocked
Applying power to the solenoid;
remains unlocked while power is on.
Cannot be locked
Always unlocked
Removing power from the solenoid
Deadbolt and Latchbolt retracted
simultaneously by:
• Inside knob/lever
• Outside knob/lever when power
is removed
Cannot be locked
Always unlocked
Applying power to the solenoid;
remains unlocked while power is on.
Deadbolt and Latchbolt retracted
simultaneously by:
• Inside knob/lever
• Outside knob/lever when power is
applied
Cannot be locked
Always unlocked
Cannot be locked
Removing power from the solenoid
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts the deadbolt
and latchbolt simultaneously
• Outside lever when power is removed
Always unlocked
Cannot be locked
Applying power to the solenoid;
remains locked while power is on.
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts the deadbolt
and latchbolt simultaneously
• Outside knob/lever when power is
applied
Always unlocked
Powered by 12V DC. temperature control module is not needed.
Removing power from the
• Outside knob/lever when power is
solenoid
removed from the solenoid
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
Applying power to the
• Outside knob/lever when power is
removed from the solenoid
solenoid; remains locked
while power is on.
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
NXEU–­Unlocked • Outside knob/lever when power is
Removing power from the
solenoid
removed from the solenoid
Fail Secure
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
TDEL–Locked
Fail Safe
Applying power to the
• Outside key
solenoid; remains locked
• Outside knob/lever when while power is on.
power is removed from the solenoid.
Deadbolt operated by:
• Inside knob/lever
• Outside key
Latchbolt is deadlocked by an
• Inside thumb turn
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
TDEU–Unlocked • Outside knob/lever when power is
removed from the solenoid
Fail Secure
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
LEL–Locked
Fail Safe
LEU–­Unlocked
Fail Secure
Removing power from the
solenoid
Deadbolt operated by:
• Outside key
• Inside thumb turn
Powered by 12V DC. temperature control module is not needed.
Applying power to the
• Outside knob/lever when power is
solenoid; remains locked
removed from the solenoid
while power is on.
• Inside knob/lever
Deadbolt extended by:
Latchbolt is deadlocked by an
Inside thumb turn
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
Removing power from the
• Outside knob/lever when power is
solenoid
removed from the solenoid
Deadbolt extended by:
• Outside key
Inside thumb turn
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12V DC. temperature control module is not needed.
Shading indicates a ridged lever/knob in a non-energized state.
W & M Series IDH MAX® & Electromechanical Locks
5
9KM IDH MAX® – Specifications
Mechanical
Materials – Internal parts are brass, zinc or corrosion-treated steel.
Chassis – 2 1⁄16” diameter to fit 2 1⁄8” diameter hole in door.
Strike – Brass, bronze, or stainless steel base material; STK 2 3/4” H standard, S3 4 7/8” H.
Fits standard door frame cut out as specified in ANSI A115.1. Strike box supplied as standard.
Backset – 2 3⁄4” standard, 3 3⁄4” and 5” available.
Door Thickness – Standard lock configuration designed for doors 1 3/4” – 2 1/4” thick.
Installation – Lock dimensions requires modified door prep ANSI A156.2 Series 4000, Grade 1 to mount housing.
Latchbolt – 9⁄16” throw.
9KM IDH MAX®
Escutcheons – 10 1/2” H x 3 5/16” W x 1” D (1” at the top, sloping down to 3/4” at the bottom).
Cylindrical
Knobs – Diameter: 2 1⁄8” Projection on door: 2 7⁄8” #4, #6 knobs: Material machined from brass or bronze.
Lever handle – Made from high-quality zinc alloy. Body is approximately 1 5⁄8” in diameter: Handle is
approximately 4 3⁄4” in length (from center-line of chassis). Lever styles 14 and 15 return to a minimum of 1/2”
of door surface. Lever 16 does not return.
Finish –
• 605-bright brass, clear coated
• 612-satin bronze, clear coated
• 626-satin chromium plated
• 606-satin brass, clear coated
• 613*-oxidized satin bronze, oil rubbed
• 690**-dark bronze
• 611-bright bronze, clear coated
• 625-bright chromium plated
* 613 finish is designed to wear over time, providing an “antique” appearance. ** 690 finish will continue as a dark brown appearance over time.
Antimicrobial Finishes –
• 626AM – Satin Chrome Plated with UltraShield Antimicrobial coating
• 630AM – Satin Stainless Steel with UltraShield Antimicrobial coating
Electronic
Maximum Current Draw – 850 MilliAmps, for 50 milliseconds
Typical Current Draw (hold condition) – 550 milliAmps
Voltage – 10.2 to 13.2 V (DC only)
Magnetic Stripe Card Reader:
Read Rate – 5 inches per second to 50 inches per second.
Card Thickness – ISO standard .030” ± .003 thick. Compliance to FCC, Canadian, and European EMC requirements; for interference
FCC Class A digital ap­pa­ra­tus.
Proximity Reader – ANSI/BHMA A156.25 compliant, Compatible with Motorola / Indala and HID proximity cards, ABA and Wiegand output
Weatherproof bezel and gasket provide protection for outdoor use. (Usable in most environmental/exterior applications).
Card Read Range – 0 – 3 inches. Compliance to US FCC, Canadian FCC, and European EMC requirements
ESD Protection – 15 Kilo Volt
9KM/8KM IDH MAX® – How To Order
9KM3
7
DDEU
14
MS
STK
Trim
Style
Strike
Finishes**
Package
Levers
DDEU–
electrically 14– curved return
unlocked
15– curved angle
DDEL–
return
electrically
16– curved no
locked
return
Knobs
4– round
6– tulip
MS–magnetic
stripe
PM–
proximity
Motorola
PH– proximity
HID
STK– 2 3/4”
ANSI
S3– 4 7/8” ANSI
(page 7)
(page 11)
Series
Core
Function Lever/Knob
Style
Backset Housing
Lever
9KM3–
2 3/4”
9KM4–
3 3/4”
9KM5–
5”
Knob
8KM3–
2 3/4”
8KM4–
3 3/4”
8KM5–
5”
0– keyless
7– 7 pin
housing
accepts all BEST®
cores
(page 11)
626
605 606 611 612
613 618 619 625
626 690
Antimicrobial
Finishes
626AM – Satin
Chrome Plated
with UltraShield
Antimicrobial
coating
630AM – Satin
Stainless Steel
with UltraShield
Antimicrobial
coating
TL
Options*
8KM:
BRK – breakaway knob, KNL – knurled knob,
TAC – tactile knob
9KM:
AL – abrasive lever, LM – lost motion,
TL – tactile lever
Note: specify inside (I), outside (O), or both
(B) for AL, TL,TAC, KNL options
Both 8KM & 9KM:
C – quick connect, SH – security head screws
3/4 – 3/4” throw latch
1300 – Mercury direct connect ***
(page 3)
* Please reference the BEST price list for a complete list of options. ** Handles and trim are made from a zinc alloy, and have been plated to be equivalent in
appearance to the finishes listed. *** 1300 option not available on any “EL” electrically locked functions.
6
W & M Series IDH MAX® & Electromechanical Locks
Cylindrical Lock – Functions
Function
Latch
Operated by
DDEL–Locked
DDEU–Un­locked
Outside Knob/Lever
Locked by
Unlocked by
Applying power to the
• Rotating the inside knob/lever,
• Rotating the outside knob/lever– only when solenoid; remains locked
while power is on.
power is off,
• Turning the key in the outside knob/lever.
Latchbolt is deadlocked
Powered by 12V DC. Temperature control module (TCM) is not needed.
Removing power from the
• Rotating the inside knob/lever,
• Rotating the outside knob/lever– only when solenoid
power is on,
• Turning the key in the outside knob/lever.
Latchbolt is deadlocked
Inside Knob/Lever
Locked by
Unlocked by
Removing power from
the solenoid
Cannot be locked
Always unlocked
Applying power to
the solenoid; remains
unlocked while power
is on.
Cannot be locked
Always unlocked
Powered by 12V DC. Temperature control module (TCM) is not needed.
Shading indicates a ridged lever/knob in a non-energized state.
40HW/8KW/9KW Electrified Lock Introduction
The 40HW, 8KW, and 9KW electromechanical locks provide fail-safe (electrically locked) and fail-secure (electrically unlocked) operation.
They also provide a way to lock and unlock the door from a remote location for safety, security, or convenience through an individual
switch, switch lock, relay, access control system, or other automatic control system. More importantly, these locks exhibit the same features
and meet the same standards and specifications as our mechanical 40H mortise and 8K/9K heavy duty cylindrical locksets.
How To Order BEST Quick Connect Pre-Wired Plug-In Connectors
To order the BEST Quick Connect pre-wired plug-in connectors, include the “C” suffix for the BEST Locks. See page 20 for more details on
how the BEST Quick Connect systems works.
Example:
BEST Locks
45HW 7 DEL 14H 626 RH DSC
BEST Locks
9KW 37 DEU 15CS TK 626 24 VC
40HW Electrified – Specifications
Types:
• 12 volts AC or DC — 0.60 amps
• 24 volts AC or DC — 0.45 amps
• All EU functions: Electrically Unlocked (Fail Secure)
• All EL functions: Electrically Locked (Fail Safe)
Approval Listings:
• UL listed for GYQS Electrically-controlled singlepoint locks or latches.
• This product has been approved by the California State Fire Marshal (CSFM) pursuant to section 13144.1 of the California Health
and Safety Code.
• Approved by the city of New York Board of Stan­dards and Appeals under calendar number 49-88-SA. See CSFM listing
No. 4136-1175:101 for al­low­able values and/or conditions for use concerning material pre­sent­ed in this doc­u­ment. It is subject
to re-examination, revisions and possible cancellation.
NOTE: All w-series locks require the use of a (TCM) Temperature Control Module.
TCM and TCM connector are supplied standard with every order.
W & M Series IDH MAX® & Electromechanical Locks
7
40HW Electrified – How To Order
45HW
7
NXEU
12
J
612
LH
Series
Core
Housing
Function
Lever
Style
Trim
Style
Finishes
Handing Options
45HW– lever
47HW– lever
high security
45HW:
0– keyless or
less cylinder,
7– 7 pin
IC housing
accepts all
BEST cores
47HW:
7– 7 pin
(accepts 5C
cores only)
45HW/47HW:
DEL–single key latch, fail safe
DEU– single key latch, fail secure
WEL– double key latch, fail safe
WEU– double key latch, fail secure
TDEL–single key deadbolt, fail safe
TDEU–single key deadbolt, fail secure
TWEL–double key deadbolt, fail safe
TWEU–double key deadbolt, fail secure
45HW only:
NXEL–keyless, latch, fail safe
NXEU–keyless, latch, fail secure
LEL– keyless, deadbolt, fail safe
LEU– keyless, deadbolt, fail secure
Levers:
3– solid tube/
return
12– solid tube/no
return
14– curved return
15– contour/angle
return
16– curved/no
return
17– gullwing no
return
Knobs:
4– round
45HW:
H– 2 3/4” flat
J– wrought
M– forged
N– forged
con­cealed
cylinder*
S– 3 1/2” flat
R– 2 3/4”
concave
47HW:
M– forged
45HW:
605 606
611 612
613 618
619 625
626 690
RH
RHRB
LH
LHRB
(pages 8–9)
(page 11)
(page 11)
47HW:
626 630
RQE
AL – abrasive lever
C – quick connect
LL – lead lined
LS – latch status
DS – door status
RQE – request
to exit
SH – security head
screws
TL – tactile lever
Thick Door –
specify thickness if
other than 1 3/4”
(1 3/4” min x
4” max)
12V–Specify
12 Volt System
(standard lock
voltage is 24V)
(page 3)
* “N” trim not available on double keyed functions.
40HW Electrified – Functions
Function
DEL–Locked
Fail Safe
DEU–Unlocked
Fail Secure
WEL–Locked
Fail Safe
WEU–Un­locked
Fail Secure
TDEL–Locked
Fail Safe
Latch
Operated by
Locked by
Outside Knob/Lever
Unlocked by
Inside Knob/Lever
Locked by
Unlocked by
Removing power from solenoid
Cannot be locked
Applying power to solenoid;
• Outside knob/lever when
power is removed from the remains locked while power
is on
solenoid
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
Removing power from
Applying power to solenoid; remains Cannot be locked
• Outside knob/lever when
solenoid
unlocked while power is on
power is applied to the solenoid
• Outside key
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
Always unlocked
Removing power
Removing power from solenoid
Applying power to
Applying power to solenoid;
• Inside and Outside knob/
the solenoid; remains from the solenoid
remains locked while power
lever when power is
locked while power
removed from the solenoid is on
is on
• Inside/Outside key
Latchbolt is deadlocked by an
auxiliary latch
Temperature control module (TCM) included.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.
Removing power from
Applying power to solenoid; remains Removing power
Applying power to
• Inside and Outside knob/
unlocked while power is on
from solenoid
lever when power is applied solenoid
solenoid; remains
to the solenoid
unlocked while
power is on
• Inside/Outside key
Latchbolt is deadlocked by an
auxiliary latch
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Removing voltage locks inside & outside knobs/levers simultaneously.
Temperature control module (TCM) included.
• Outside key
• Outside knob/lever when
power is removed from the
solenoid
Latchbolt is deadlocked by an
auxiliary latch
Applying power to solenoid;
remains locked while power
is on
Deadbolt operated by:
• Outside key
• Inside thumb turn
Cannot be locked
Removing power from solenoid
Deadbolt and latchbolt retracted
simultaneously by:
• Inside knob/lever
• Outside knob/lever when power is removed.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
8
Always unlocked
W & M Series IDH MAX® & Electromechanical Locks
Always unlocked
40HW Electrified – Functions (Continued)
Function
TDEU–Unlocked
Fail Secure
Latch
Operated by
• Outside key
• Outside knob/lever when
power is applied to the
solenoid
Latchbolt is deadlocked by an
auxiliary latch
Locked by
Outside Knob/Lever
Unlocked by
Removing power from
solenoid
Deadbolt operated by:
• Outside key
• Inside thumb turn
Applying power to solenoid; remains
unlocked while power is on
Deadbolt and latchbolt retracted
simultaneously by:
• Inside knob/lever
• Outside knob/lever when power
is applied.
Inside Knob/Lever
Locked by
Unlocked by
Cannot be locked
Always unlocked
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
TWEL–Locked
Fail Safe
• Outside & inside key
• Outside & Inside knob/ lever
when power is removed
from the solenoid
Latchbolt is deadlocked by an
auxiliary latch
Applying power to solenoid;
remains locked while power
is on
Deadbolt operated by:
• Outside or inside key
• Outside & Inside knob/lever
when power is removed
from the solenoid
Removing power from solenoid
Applying power to
solenoid; remains
locked while power is
on
Removing power
from solenoid
Temperature control module (TCM) included.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.
TWEU–Un­locked • Outside & inside key
Fail Secure
• Outside & Inside knob/lever
when power is applied to
the solenoid
Latchbolt is deadlocked by an
auxiliary latch
Applying power to solenoid; remains
Removing power from
unlocked while power is on
solenoid
Deadbolt operated by:
• Outside or inside key
• Outside & Inside knob/lever when power is applied to
the solenoid
Removing power
from solenoid
Applying power to
solenoid; remains
unlocked while
power is on
Temperature control module (TCM) included.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Removing voltage locks inside & outside knobs/levers simultaneously.
NXEL–Locked
Fail Safe
•Outside knob/lever when
power is applied to the
solenoid
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Applying power to
solenoid; remains locked while
power is on
Removing power from solenoid
Cannot be locked
Always unlocked
Temperature control module (TCM) included.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
NXEU–Unlocked
Fail Secure
• Outside knob/lever when
power is applied to the
solenoid
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Removing power from
solenoid
Applying power to solenoid; remains
unlocked while power is on
Cannot be locked
Always unlocked
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
LEL–Locked
Fail Safe
• Outside knob/lever when
power is removed from the
solenoid
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Applying power to the
solenoid; remains locked while
power is on
Deadbolt extended by:
Inside thumb turn
Removing power from the solenoid
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts
the deadbolt and latchbolt
simultaneously
• Outside knob/lever when power is
removed
Cannot be locked
Always unlocked
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
LEU–­Unlocked
Fail Secure
• Outside knob/lever when
power is applied to the
solenoid
• Inside knob/lever
Latchbolt is deadlocked by an
auxiliary latch
Removing power from the
solenoid
Deadbolt extended by: Inside
thumb turn
Applying power to the solenoid;
remains unlocked while power is on
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts
the deadbolt and latchbolt
simultaneously
• Outside knob/lever when power
is applied
Cannot be locked
Always unlocked
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
ATTENTION: Locksets that secure both sides of the door are controlled by building codes and the Life Safety Code®.
In an emergency exit situation, failure to quickly unlock the inside lever could be hazardous or even fatal.
W & M Series IDH MAX® & Electromechanical Locks
9
8KW & 9KW Electrified Locks – Specifications
Types:
• 12 volts AC/DC when used with supplied TCM — 0.50 amps
• 24 volts AC/DC when used with supplied TCM — 0.18 amps
• All EU functions: Electrically Unlocked (Fail Secure)
• All EL functions: Electrically Locked (Fail Safe)
Approval Listings:
• UL listed for GYQS Elec­tri­cal­ly-controlled singlepoint locks or latches.
• This product has been approved by the California State Fire Marshal (CSFM)
pur­su­ant to section 13144.1 of the California Health and Safety Code.
• Approved by the city of New York Board of Standards and Appeals under
calendar number 730-89-SA. See CSFM listing No. 4136-1175:103. It is
subject to re-examination, revision and possible cancellation.
Door thickness:
• Standard lock configuration designed for doors 1 3/4” – 2 1/4” thick.
9KW Cylindrical
Electrically-Operated Lockset
NOTE: All W-series locks require the use of a (TCM) Temperature Control Module.
A TCM and TCM connector are supplied standard with every order.
8KW & 9KW Electrified Locks – How To Order
9KW3
7
Series
8KW:
8KW3– 2 3/4”
8KW4– 3 3/4”
8KW5– 5”
DEU
14
K
STK
626
Core
Function
Housing
Lever
Style
Trim
Style
Srike
Package
Finishes* Options
0– keyless
7– 7 pin
housing
accepts all
BEST® cores
DEU–
electricallyunlocked
DEL–electricallylocked
8KW:
4–round
6–tulip
9KW:
14– curved
return
15– contour angle return
16– curved no return
C– 3” convex
D– 3 1/2”
convex
K– 3” convex
–no ring
L– 3 1/2”
convex –no
ring
STK –
2 3/4” ANSI
S3 –
4 7/8”ANSI
605
611
613
619
626
(See Below)
(page 11)
(page 11)
9KW:
9KW3– 2 3/4”
9KW4– 3 3/4”
9KW5– 5”
TL
606
612
618
625
690
8KW only:
BRK– breakaway knob
KNL– knurled knob
TAC– tactile knob
9KW only:
AL– abrasive lever
LM– lost motion
RQE– request-to-exit
TL– tactile lever
Note: specify inside (I), outside (O), or both (B) for AL, TL, TAC, KNL options
8KW & 9KW:
C – quick connect
LL– lead lined
SH– security head screws
3/4– 3/4” throw latch
12V– Specify 12 Volt System (standard lock
voltage is 24V)
(page 3)
* Handles are made from a zinc alloy, and have been plated to be equivalent in appearance to the finishes listed.
8KW & 9KW Electrified Locks – Functions
Function
DEL-Locked
DEU-Un­locked
Latch
Operated by
Outside Knob/Lever
Locked by
Unlocked by
Removing power from
Cannot be locked
Applying power to the
• Rotating the inside
the solenoid
solenoid; remains locked
knob/lever
• Rotating the outside knob/lever—only while power is on.
when power is off
• Turning the key in the outside knob/lever.
Locks are powered by 12 or 24 volts AC/DC at 0.50 amps or 0.18 amps. Temperature control module (TCM) included
Cannot be locked
Removing power from the
Applying power to the
• Rotating the inside knob/lever,
solenoid
solenoid; remains
• Rotating the outside knob/lever—only
unlocked while power
when power is on,
is on.
•Turning the key in the outside knob/lever.
Locks are powered by 12 or 24 volts AC/DC at 0.50 amps. or 0.18 amps. Temperature control module (TCM) included
Shading indicates a ridged lever/ knob in a non-energized state.
10
Inside Knob/Lever
Locked by
Unlocked by
W & M Series IDH MAX® & Electromechanical Locks
Always unlocked
Always unlocked
Knob Styles
#4 knob
#6 knob
Lever Styles
#3 lever
#12 lever
#14 lever
#15 lever
#16 lever
#17 lever
Mortise Rose Trims
Cylindrical Rose Trims
H rose
C rose
R rose
S rose
D rose
L rose
K rose
Escutcheon Trim Variations
J escutcheon
M escutcheon
N escutcheon
MS escutcheon
Prox escutcheon
W & M Series IDH MAX® & Electromechanical Locks
11
ELECTRIFIED ACCESSORIES
8W599 Features:
• Offers exceptionally high power for its
compact size
• UL listed
• Thermally fused
• Convenient 4 point mounting provision
allows rapid installation in a standard 1/2”
knockout
• Foot-mounts for surface installation
• Pre-stripped pigtails provided for quick
primary connection
• Secondary connection by screw terminals
• Sturdy nylon bobbin construction
• Cadmium plated finish
Transformer
Specifications:
Primary voltage – 120 VAC (Wire Leads)
Secondary voltage – 124 VAC (Screw Terminals)
Secondary VA – 140 volts-amperes
Dimensions – 12 1/4” x 2 1/8” x 2 15/16”
To order specify: 18W599
8WCON Features:
• 400 Ampere surge capability
• Electrically isolated base
Function/Application:
Transforms 120 volts AC to 24 volts AC.
(To get 24 volts DC, use with 8WCON,
AC to DC converter.) Typ­i­cal­ly used as a
power supply for electrically-op­er­at­ed locks.
• UL recognized
• Single-phase, full wave bridge
Specifications:
Average forward current – 25 amps
AC to DC Converter
Case – Plastic case with an electrically isolated aluminum base
Full wave bridge rectifier
Polarity – Terminal designation embossed on case: +DC output, -DC output, AC not marked
Mounting position – Bolt down. Gain the highest heat transfer ef­fi­cien­cy through the surface op­po­site the terminals.
Use silicone heat sink compound on mounting surface for max­i­mum heat transfer.
Terminals – Suitable for “fast-on” connections. Readily solderable and corrosion resistant. Soldering is recommended for applications
greater than15 amperes.
Mounting torque – 20 inch-pounds maximum
Case size – 1.030 x 1.030 inches
Temperature range – -85° to 347°F (-65­° to + 175°C)
To order specify: 8WCON
Function/Application:
Converts AC (alternating current) to DC (direct current) for locking circuit applications. (Typ­i­cal­ly used with 8W599 transformer.)
8WBU-1-A / 8WBU-1-N Features:
• Positive “snap” feedback
• Industrial-grade switch designed for rugged control applications
• Factory assembled with trimplate
Specifications:
Electrical rating – 28VDC or 115 VAC, 10A resistive, 5A
in­duc­tive, 3A lamp load (see ter­mi­nol­o­gy on the back cover)
Switch type – SPST-NO-DB, FORM-X contacts, 25,000 cycles
at full load, 50,000 cycles me­chan­i­cal life
Mounting hole – 5/8” (.625) dia.
Switch dim. – 1.187 dia.x 1.528 overall length
Standard wall plate – 2 3/4” x 4 1/2”
Narrow wall plate – 1 1/2” x 4 1/2”
Material/finish –
Satin stainless steel
12
W & M Series IDH MAX® & Electromechanical Locks
• Standard or narrow plate available
• 1 3/16” dia. mushroom head—
red in color
Wire leads –
Two 6” long 20 AWG insulated wire leads
To order specify – 8WBU-1-A stan­dard
plate 8WBU-1-N narrow plate
To order specify: 8WCON
Function/Application:
Converts AC (alternating current)
to DC (direct current) for locking circuit
applications. (Typ­i­cal­ly used with
8W599 transformer.)
8WBU-1-A
Standard plate
8WBU-1-N
Narrow plate
ELECTRIFIED ACCESSORIES
Temperature control module Features
• All circuitry completely sealed
Specifications
• Wire leads: Input – 24 AWG – Stranded wire with PVC insulation (approx. 44” in length)
• Output – 24 AWG – Stranded wire with Teflon insulation (approx. 2.6” in length)
• Input Voltage: 12 or 24 volts AC or DC
• Output Voltage: Full voltage out @ 1 amp maximum for 0.5 seconds then 30% of
voltage out for 5 seconds
• Output protection: Short circuit current limiting set at one (1) amp.
• Operating temp: -4 to 158°F (-20 to 70°C)
• Size: 1/2” x 2 1/4” x 1/2”
Temperature
control module
Function/Application
A temperature control module (TCM) reduces the amount of current flow to a lockset one second after energizing, thereby lowering the tem­per­a­ture of the lockset
trim. A (TCM) also converts AC power to DC power and should be used on all electrified
mortise and cylindrical locksets.
NOTE: The TCM is not used with any IDH-Max function.
TERMINOLOGY
Closed – A state in which a connection exists between the common terminal and another terminal on the switch.
See Open also.
Common terminal – A terminal on a switch whose contact can be connected to one or more terminals on the switch.
Door status – A switch that monitors whether the door is open or closed. This switch is used to detect a forced entry, or a door that is
propped open.
Inductive load – An electrical device such as a motor, relay, or solenoid.
NOTE: this type of load can cause arcing across switch con­tacts and may burn the contacts. See Resistive load and Lamp load also.
Latchbolt status – A switch that monitors whether the latch is engaged or retracted. This switch is used to detect a forced entry, or a
latch that has been taped open.
Lamp load – An electrical device that produces light using a tungsten filament, such as an incandescent light bulb.
Note: this type of load can cause surges of current upon contact closure. This may cause the contacts to weld together. See Inductive load and Resistive load also.
Maintained – Remaining in a given state until the switch lever or button is actuated. Actuating the switch lever or button causes the
switch to change to another maintained state.
Momentary – Remaining in a given state only as long as an external force is applied to the switch lever or button.
NC – (Normally Closed) Switch contacts that are closed as long as no external force is applied to the switch lever or button.
NO – (Normally Open) Switch contacts that are open as long as no external force is applied to the switch lever or button.
Open – A state in which no connection exists between the common terminal or any other terminal on the switch.
Pole – The number of independent circuits in a switch. For example, a double-pole, single-throw switch can control two separately
powered motors.
See Throw also.
Resistive load – An electrical device, such as a heater, having none of the char­ac­ter­is­tics of an inductive or lamp load. This type of load is
the least severe on the switch because only a small amount of arcing occurs when the switch contacts open and close.
See Inductive load and Lamp load also.
RQE – Request-to-exit. A switch that allows the user to exit without setting off an alarm. Turning the inside knob or lever actuates the
switch and, when wired to an alarm system, sends a signal to disable or sound an alarm, start a timer, etc.
Throw – The number of circuits, or contacts controlled by each pole. For example, a single-pole, double-throw switch can control a motor
with two contacts—a forward contact, and a reverse contact.
See Pole also.
1300 – Integrated BAS1300/LNL1300 reader electronics board or (ISC) Intelligent System Controller is embedded behind the escutcheon
secured and out of site. Functions with Mercury on-line equipment only.
W & M Series IDH MAX® & Electromechanical Locks
13
Electric Switch Lock – Introduction
BEST offers a line of electric switch locks available in various “on-off” and “mo­men­tary” keyed switch func­tions.
Circuitry vari­at­ions are available in single, double and triple pole with varied voltage and amperage ratings. Units may be keyed into any BEST®
system. The BEST in­ter­change­able core offers ver­sa­til­i­ty and adapt­abil­i­ty for new and existing electrical controls, panels, machines, etc.
Features
• Double D lock cylinder prevents slipping and turning
• Screw terminals on all switch locks (except the 1W7A1) provides ease of installation
• All switches are UL recognized or listed
Note on functionality: Switch lock keys can only be removed in the 12 o’clock position.
How to select a switch lock
1. Determine the electrical requirements for the device being controlled:
A. Voltage (for example: 115 VAC or 24 VDC)
B. Current or horsepower (for example: 6 amps or 1/2 horsepower)
C. Type of load
• Resistive (for example, heat­er elements)
• Inductive (for example, mo­tors, large transformers)
• Lamp (for example, in­can­des­cent lights)
2. Determine the switch configuration (poles and throws) and key re­mov­al condition:
A. Poles To determine the number of poles, find how many wires from the power source need to be switched on and off
by the switch lock.
B. Throws To determine the number of throws, find how many wires to the device the switch needs to control. For example, if a switch
needs two different “on” conditions (low and high speed), two throws are needed. Or if the device is simply an “on-off” type (only
one wire), you need one throw.
NOTE: A switch throw may be left unwired and used as an “off” condition.
C. Key removal To determine the key removal condition, ask the question, “When the key is removed, should the switch be “off”, or could the switch be either “on” or “off” ?” Although the key can only be removed in the 12 o’clock position, the switch itself may
be left in two or three positions. Check each switch lock for key removal switch positions.
3. Use the information collected and find the switch lock that best meets the requirements. Refer to the following catalog pages for a
de­scrip­tion of each switch lock. If en­vi­ron­men­tal conditions make it necessary that the switch lock be housed in an electrical box, see the Optional boxes below for the box that best suits the switch lock and your application.
Optional Boxes
OC1
Standard octagon
3 1/2” x 3 1/2” x 1 5/8”
OC2
Deep octagon
3 1/2” x 3 1/2” x 3 1/4”
INT
Interior box
4” x 2 1/8” x 1 7/8”
How To Order – 1W Electric Switch Lock
1W
7
B1
626
SWR
Series
Core Housing
Func­tion
Finishes
Box
1W
7–7 pin housing accepts all
BEST® cores
see pages 15–19
605
611
613
622
626
OC1
OC2
INT
SWR
14
606
612
619
625
690
W & M Series IDH MAX® & Electromechanical Locks
SWR
Standard weather
resistant box
4 5/8” x 2 7/8” x 3”
1W Electric Switch Locks
1W7A1
Contacts – Silver or gold flash
Contact rating –
28 VDC, 10 amps resistive
28 VDC, 3 amps inductive, lamp
125 VAC, 10.1 amps resistive
250 VAC, 10.1 amps resistive
Horsepower rating – 125 VAC, 1/4 HP
Operating temperature – -85°F to +257°F
(-65° to +125°C)
Switch type – SPDT (Single pole-double throw)
Switch lock action – Maintained
Number of switches per assembly – One
1W7A1
7/8”
15/32”
Hole cutout
Back view
Key & switch positions
Side view
Remove key
Optional box­es
SWR
INT
OCT
Key pos.1– Swt. pos.1
Key pos.2– Swt. pos.2
Key pos. 1 only - Swt. pos. 1
1W7B1 & 1W7J1
Contact rating –
30 VDC, 15 amps, resistive
125 VDC, 0.6 amps, resistive
250 VDC, 0.3 amps, resistive
125 VAC, 15 amps, resistive
25 VAC, 5 amps, lamp
250 VAC, 15 amps, resistive
Horsepower rating – 125–250 VAC, 1/2 HP
Operating temperature – -up to +176°F (+80°C)
Switch type – SPDT (Single pole-double throw)
Switch lock action – Maintained
Number of switches per assembly –
1W7B1: One, 1W7J1: Two
1W7B1—One switch
7/8”
1 5/32”
Hole cutout
Back view
Side view
1W7J1—Two switches
The shaded area shows the additional 1W7J1 switch and cam length.
Key & switch positions
Remove key
Optional box­es
OC1 (1W7B1 only)
OC2
INT
SWR
Key pos.1– Swt. pos.1
Key pos.2– Swt. pos.2
Key pos. 1 only - Swt. pos. 1
W & M Series IDH MAX® & Electromechanical Locks
15
1W Electric Switch Locks (Continued)
1W7B2 & 1W7J2
Contact rating –
0 VDC, 15 amps, resistive
125 VDC, 0.6 amps, resistive
250 VDC, 0.3 amps, resistive
125 VAC, 15 amps, resistive
125 VAC, 5 amps, lamp
250 VAC, 15 amps, resisti
Horsepower rating – 125–250 VAC, 1/2 HP
Operating temperature – up to +176°F
(+80°C)
Switch type – SPDT (Single pole-double throw)
Switch lock action – Maintained
Number of switches per assembly –
1W7B2: One, 1W7J2: Two
1W7B2—One switch
7/8”
1 5/32”
Hole cutout
Back view
Side view
The shaded area shows the additional 1W7J2 switch and cam length.
Key & switch positions
Remove key
1W7J2—Two switches
Optional box­es
OC1 (1W7B2 only)
OC2
INT
SWR
Key pos.1– Swt. pos.1
Key pos.2– Swt. pos.2
(360°CCW)
Key pos. 1 only - Swt. pos. 1
Swt. pos. 1 and 2
1W7B3 & 1W7J3
Contact rating –
30 VDC, 15 amps, resistive
125 VDC, 0.6 amps, resistive
250 VDC, 0.3 amps, resistive
125 VAC, 15 amps, resistive
125 VAC, 5 amps, lamp
250 VAC, 15 amps, resistive
Horsepower rating – 125–250 VAC, 1/2 HP
Operating temperature – up to +176°F (+80°C)
Switch type – SPDT (Single pole-double throw)
Switch lock action – Momentary
Number of switches per assembly –
1W7B3: One, 1W7J3: Two
1W7B3—One switch
7/8”
1 5/32”
Hole cutout
Back view
1W7J3—Two switches
Side view
The shaded area shows the additional 1W7J3 switch and cam length.
Key & switch positions
Remove key
Optional box­es
OC1 (1W7B3 only)
OC2
INT
SWR
Key pos.1– Swt. pos.1
16
Key pos.2– Swt. pos.2
Key pos. 1 only - Swt. pos. 1
W & M Series IDH MAX® & Electromechanical Locks
1W7D2
Contact rating –
110 VAC or VDC, 16 amps, resistive
220 VAC or VDC, 8 amps, resistive
Horsepower rating – 1 HP @ 125–250
VAC or VDC
Operating temperature – 0°F to +150°F
(-18°C to +66°C)
Switch type – DPST (Double pole-single throw)
Switch lock action – Maintained
Number of switches per assembly – One
7/8”
1W7D2
1 5/32”
Hole cutout
Limiting plate†
Front view
Side view
Key & switch positions
Remove key
Optional box­es
SWR
Key pos.1– Swt. pos.1
Key pos.2– Swt. pos.2
Key pos. 1 only - Swt. pos. 1
†Installing the limiting plate limits key removal to switch position 1 or 2. The key is always removed in the vertical position (key position 1).
1W7B2 & 1W7J2
Contact rating –
110 VAC or VDC, 10 amps, lamp
220 VAC or VDC, 5 amps, resistive
Operating temperature – -40°F to +150°F
(-40° to +65°C)
Switch type – SPST (Single pole-single throw)
Switch lock action – Maintained
Number of switches per assembly – One
1W7C2
Front (inside) view
Key & switch positions
Side (inside) view
Remove key
Optional box­es
OC1
Key pos.1– Swt. pos.1
Key pos.2– Swt. pos.2
Key pos. 3 only
Swt. pos. 1 and 2
W & M Series IDH MAX® & Electromechanical Locks
17
1W Electric Switch Locks (Continued)
1W7E2
Contact rating –
110 VAC, 15 amps, resistive
220 VAC, 10 amps, resistive
Horsepower rating – 125–250 VAC or VDC, 3/4
HP; 1, 2, or 3 phase
Operating temperature – 0 to +150°F
(-18°C to 66°C)
Switch type – TPDT (Triple pole-double throw)
Switch lock action – Maintained
Number of switches per assembly – One
7/8”
1W7E2
1 5/32”
Hole cutout
Limiting plate*
Side view
Front view
Key & switch positions
Remove key
Optional box­es
SWR
Key pos.1
Swt. pos.1
Key pos.2
Swt. pos.2
Key pos. 1 only
Swt. pos. 1
Key pos. 1 only
Swt. pos. 1, 2, and 3*†
*Installing the limiting plate limits key removal to switch position 2, or 3. The key is always removed in the vertical position (key position 1).
1W7E2
Contact rating –
110 VAC, 15 amps, resistive
220 VAC, 10 amps, resistive
Horsepower rating – 250 VAC, 1/2 HP
Operating temperature – up to +221°F
(+105°C)
Switch type – DPDT (Double pole-double throw)
Switch lock action – Momentary
Number of switches per assembly – One
1W7K4
7/8”
1 5/32”
Hole cutout
Side view
Back view
Key & switch positions
Remove key
Optional box­es
SWR
Key pos.1
Swt. pos.1
18
Key pos.2
Swt. pos.2
Key pos. 1 only
Swt. pos. 1
W & M Series IDH MAX® & Electromechanical Locks
Key pos. 1 only
Swt. pos. 1, 2, and 3*†
1W7L2
Contact rating –
110 VAC or VDC, 12 amps, resistive
220 VAC or VDC, 6 amps, resistive
Operating temperature – up to +221°F
(+105°C)
Switch type – SPDT (Single pole-double throw)
Switch lock action – Maintained
Number of switches per assembly – One
7/8”
1W7L2
1 5/32”
Hole cutout
Limiting plate†
Side view
Front view
Key & switch positions
Remove key
Optional box­es
SWR
Key pos.1
Swt. pos.1
Key pos.2
Swt. pos.2
Key pos. 1 only
Swt. pos. 1
Key pos. 1 only
Swt. pos. 1, 2, and 3*†
†Installing the limiting plate limits key removal to switch position 1 or 2. The key is always removed in the vertical position (key position 1).
1W7P4 & 1W7R4
Contact rating –
30 VDC, 15 amps, resistive
125 VDC, 0.6 amps, resistive
250 VDC, 0.3 amps, resistive
125 VAC, 15 amps, resistive
125 VAC, 5 amps, lamp
250 VAC, 15 amps, resistive
Horsepower rating – 125–250 VAC, 1/2 HP
Operating temperature – up to +176°F (+80°C
Switch type – SPDT (Single pole-double throw)
Switch lock action – Momentary
Number of switches per assembly –
1W7P4: Two, 1W7R4: Four
1 1 /2"
2 5 /16"
1 29 /32"
1W7P4—two switches
7/8”
1 5/32”
2 7 /8"
Hole cutout
Back view
The shaded area shows the additional 1W7R4 switches and cam length.
Key & switch positions
1W7R4—four switches
Side view
Remove key
Optional box­es
SWR
INT (1W7P4 only)
Key pos.1
Swt. pos.1
Key pos.2
Swt. pos.2
Key pos. 1 only
Swt. pos. 1
Key pos. 1 only
Swt. pos. 1, 2, and 3*†
W & M Series IDH MAX® & Electromechanical Locks
19
BEST Quick Connect System
BEST Quick Connect plug-in connectors must be used with the
following components to work as a complete plug-and-play system:
1. Specify appropriate PRECISION or BEST electrified products
2. Specify correct wire harness length from door hardware to electric
power transfer device or electrified hinge
3. Specify either the NEW electric power transfer (EPT-12C) or the NEW
electrified hinge (CECB179-12C)
4. Specify correct wire harness length from power transfer or electrified
hinge to wire extension (WH-6E)
5. Choose wire harness extension to connect to power source
Wire harness
extension WH-6E
to power source 5
Pre-wired plug-in connectors
works with varying wire lengths
2
4
Wire harness
Ex. WH-192
1
Quick Connect-compatible
door hardware
3
Power transfer device
EPT-12C or electrified hinge
CECB179-12C
How To Order
To order the BEST Quick Connect pre-wired plug-in connectors, include the “C” suffix for the BEST electrified locks. See example below.
Example:
BEST Locks
45HW 7 DEL 14H 626 RH DSC
BEST Locks
9KW 37 DEU 15CS TK 626 24 VC
6161 East 75th Street
Indianapolis, IN 46250 USA
Phone 855-365-2407
bestaccess.com
BA-0002 Rev 11/5/2017
© 2017 dormakaba Holding. All rights reserved.