NEW AQUAREA RANGE 2017 – 2018
HIGH-EFFICIENCY HEAT
PUMP TECHNOLOGY
NEW AQUAREA
TECHNOLOGY
AQUAREA RANGE
NEW 2017 — 2018
Index
THE LAST GENERATION OF AIR CONDITIONING............................................................................................................4
A GLOBALLY TRUSTED AIR CONDITIONING BRAND .......................................................................................................6
100% PANASONIC, THE DNA OF JAPANESE CRAFTSMANSHIP.......................................................................................8
PANASONIC: ECO & SMART IDEAS FOR A SUSTAINABLE LIFESTYLE.............................................................................10
PROJECTS & CASE STUDIES OF PANASONIC HEATING AND COOLING SOLUTIONS.........................................................12
AQUAREA ALL IN ONE H GENERATION HIGH PERFORMANCE BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND
COOLING. 1 ZONE HYDROKIT OR 2 ZONES BUILT-IN HYDROKIT....................................................................................42
AQUAREA ALL IN ONE H GENERATION T‑CAP BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND COOLING.............43
AQUAREA ALL IN ONE HIGH PERFORMANCE BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND COOLING..............44
AQUAREA ALL IN ONE T‑CAP BI‑BLOC SINGLE PHASE. HEATING AND COOLING............................................................45
PRO CLUB. THE PROFESSIONAL WEBSITE OF PANASONIC..........................................................................................14
AQUAREA H GENERATION HIGH PERFORMANCE BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING - SDC...................................................................................................................................46
AQUAREA DESIGNER................................................................................................................................................15
AQUAREA H GENERATION T‑CAP BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND COOLING - SXC......................47
WELCOME TO AQUAREA AIR TO WATER HEAT PUMP...................................................................................................16
HIGHLIGHTED FEATURES..........................................................................................................................................18
AQUAREA H GENERATION T‑CAP BI‑BLOC THREE PHASE. SUPER QUIET OUTDOOR UNIT.
HEATING AND COOLING - SXC...................................................................................................................................48
HOW DO YOU GET HEATING AND DOMESTIC HOT WATER FROM AIR?...........................................................................20
AQUAREA HT BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING ONLY - SHF...............................................................49
AQUAREA HEAT PUMP LINE-UP.................................................................................................................................22
AQUAREA H GENERATION HIGH PERFORMANCE MONO‑BLOC SINGLE PHASE. HEATING AND COOLING - MDC................50
NEW AQUAREA H GENERATION A+++........................................................................................................................24
AQUAREA G GENERATION HIGH PERFORMANCE MONO‑BLOC SINGLE PHASE. HEATING AND COOLING - MDC................51
AQUAREA HIGH PERFORMANCE ...............................................................................................................................26
AQUAREA G GENERATION T‑CAP MONO‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND COOLING - MXC...............52
AQUAREA T-CAP.......................................................................................................................................................28
AQUAREA G GENERATION HT MONO‑BLOC SINGLE PHASE. HEATING ONLY - MHF.........................................................53
AQUAREA HT............................................................................................................................................................30
AQUAREA AIR RADIATORS FAN COILS FOR HEAT PUMP APPLICATION..........................................................................54
AQUAREA COMMERCIAL...........................................................................................................................................32
SANITARY TANKS.....................................................................................................................................................56
NEW AQUAREA SMART CLOUD FOR H GENERATION....................................................................................................34
AQUAREA DHW........................................................................................................................................................58
CONTROL & CONNECTIVITY.......................................................................................................................................35
ACCESSORIES & CONTROL.......................................................................................................................................60
REMOTE CONTROLLER.............................................................................................................................................36
PANASONIC’S AQUAREA OFFERS THE BEST FOR YOU AND YOUR HOME.......................................................................62
HEAT PUMP MANAGER.............................................................................................................................................37
HEATING & COOLING CAPACITY TABLES.....................................................................................................................64
AQUAREA + PV PANELS............................................................................................................................................38
EXAMPLES OF INSTALLATIONS..................................................................................................................................74
AQUAREA HEAT PUMPS LINE-UP...............................................................................................................................40
DIMENSIONS...........................................................................................................................................................75
Quality Management System Certificate
Certified to ISO 14001: 2004
Certified to ISO 9001: 2008
Certified to ISO 14001: 2004
Certified to ISO 9002: 1994
Certified to ISO MS 14001: 1997
Panasonic Appliances Air-Conditioning
Malaysia. Sdn.Bhd.
Cert. No.: MY-AR 1010
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 01209Q20645R5L
2
Environmental Management System Certificate
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(PHAAM) (Fomerly know as Matsushita
Industrial Corp. Sdn. Bhd.)
Registration No.: AR 0866
Panasonic Appliances Air-Conditioning
Malaysia Sdn.Bhd.
Cert. No.: MY-ER0112
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 02110E10562R4L
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(PHAAM) (Fomerly know as Matsushita
Industrial Corp. Sdn. Bhd.)
Cert. No.: M015802127
New Aquarea H Generation A+++.
The beauty of comfort. The new H Generation is being introduced ranging
from 3 to 16kW. The small capacity units are specially designed for low
energy homes and achieve an impressive COP of 5 (on the 3kW).
New All in One H Generation.
The new All in One solution from 3 to 16kW with 200L stainless tank with
free maintenance. The “A” class pump provides a small foot print and
ideal solution for new, retrofit homes.
DHW tank with built-in Heat Pump.
The Heat Pump is one of the most energy efficient and cost effective
methods of water heating. The pump is mounted on the storage tank and
draws energy from the ambient air, using that extra energy source to heat
the water up to 55°C.
New Mono‑Bloc Generation.
The “A” class water pump equipped with the new remote controller
maximises savings while improving the performance and comfort.
New Aquarea Smart Cloud.
The Aquarea Smart Cloud is a powerful and intuitive service for remotely
controlling the full range of heating and hot water functions, including
monitoring energy consumption.
3
THE LAST GENERATION OF
AIR CONDITIONING
NEW PANASONIC
TECHNOLOGY
4
NEW / EDITORIAL
Panasonic is committed to creating a better life and
a better world thanks to its breakthrough technology,
continuously contributing to the evolution of society and to
the happiness of people around the globe.
Constantly Improving
At Panasonic, we know that the best is always yet to come. This is why our air conditioning and heat pump solutions are constantly upgraded. We are
always looking to improve our technology; finding the most efficient solutions that save our customers money.
Our Technology & Design teams anticipate the needs of tomorrow. We look to produce smaller, quieter, efficient solutions - with better technological
features – that can reduce energy consumption while providing suitable temperature conditions for the user.
NEW DOMESTIC
TECHNOLOGY
Look ahead to the “Future,” keep taking on challenges
Starting 1918, Panasonic has constantly added to its guarantee for innovation,
taking tomorrow’s technologies and applying them to today’s needs.
Always making “people” central to our activities, and thereby focusing on
“people’s lives,” we will continue to provide better living for our customers. This
is the unchanging commitment we at Panasonic have had over many years.
We are aiming for now is to expand our contribution to “better living” everywhere.
This means that in the variety of spaces where our customers go about their
lives, ranging from inside the home, the office, the store, the automobile, and the
airplane, as well as the town, we will provide not only single pieces of hardware,
NEW AQUAREA
TECHNOLOGY
NEW PACi
TECHNOLOGY
NEW VRF
TECHNOLOGY
but also total solutions including software and services. We will pursue the
concept of “A Better Life, A Better World,” meeting the needs of each
individual customer.
To that end, we will leverage the strengths that we at Panasonic have long
developed in our consumer electronics business, the strengths of our business
partners who have in-depth expertise in many areas, and will work to combine
these strengths by pursuing “Cross-Value Innovation.” In this way, we will
create new value. This is the new and challenging task we are now
addressing.
5
A GLOBALLY TRUSTED AIR
CONDITIONING BRAND
6
Testing laboratory Panasonic Gunma, Japan (PAPARS).
NEW / EDITORIAL
Panasonic – leading the way in Heating and Cooling.
With more than 30 years of experience, selling to more
than 120 countries around the world, Panasonic is
unquestionably one of the leaders in the heating and
cooling sector.
With a diverse network of production and R&D facilities, Panasonic
delivers innovative products incorporating cutting-edge technologies that
set the standard for air conditioners worldwide.
Expanding globally, Panasonic provides superior international products
transcending borders.
100% Panasonic: we control the process
The company is also a world leader in innovation as it has filed more than
91,539 patents to improve its customers’ lives. Moreover, Panasonic is
determined to remain at the forefront of its market. In all, the company
has produced more than 200 million compressors and its products are
manufactured in 294 plants which are located all over the world. You can
be assured of the extremely high quality of Panasonic’s heat pumps.
This wish to excel has made Panasonic the international leader in heating
and turn-key air conditioning solutions. These offer maximum
effectiveness, comply with the strictest environmental standards and
meet the most avant-garde construction requirements of our time.
History of Air Conditioning Group
Panasonic starts with a desire to create things of value. As hard work and dedication results in one innovative product after another, the new company took
its first steps towards becoming the electronics giant of today.
Heating and Cooling Solutions designed and produced by Panasonic since 1958. See more information on www.aircon.panasonic.eu
1958
1971
1973
1975
1985
First room air conditioner
launched for domestic
installation.
Starts production of
absorption chillers.
Panasonic launches the first
highly efficient air-to-water
heat pump in Japan.
Panasonic becomes the first
Japanese air conditioner
manufacturer in Europe.
Introduces first GHP (gas heat
pump) VRF air conditioner.
1989
2008
2010
2012
Looking ahead
Introduces world’s first
simultaneous 3-Pipe heating/
cooling VRF system.
Etherea new concept of air
conditioning systems: high
efficiency and high
performances with a great
design.
New Aquarea.
Panasonic has created
Aquarea, an innovative new,
low-energy system.
New GHP units. Pansonic’s
gas-driven VRF systems are
ideal for projects where
power restrictions apply.
New VRF Systems ECOi EX
with Extraordinary EnergySaving Performance and
Powerful Operation EER 4,7.
7
100% PANASONIC, THE DNA OF
JAPANESE CRAFTSMANSHIP
JAPAN
QUALITY
8
NEW / EDITORIAL
Applying advanced technologies that truly make life better,
we live by an unparalleled commitment to product quality.
Panasonic is building on the Japanese tradition of
uncompromising quality control worldwide, developing
and manufacturing fine products and delivering them to
customers everywhere.
At Panasonic, we believe that the best air conditioner is one that
works quietly and effectively in the background whilst minimising
its impact on the environment
People who use our products can look forward to long years of highquality performance without the need for constant service. As part of our
rigorous design and development process, Panasonic air conditioners
undergo a variety of stringent tests to ensure their effectiveness and
long-term reliability. Tests for durability, waterproofing, shock resistance,
and noise are conducted on component parts or on the finished products
themselves.
As a result of all of these time consuming efforts, Panasonic air
conditioners meet even the most demanding industrial standards and
regulations in every country where they are sold.
International Standard Quality
To uphold the company’s reputation around the world, Panasonic strives continuously to offer the highest quality with the lowest possible environmental
impact.
Reliable parts that meet or exceed
industrial standards
In every country where they are sold, Panasonic
air conditioners comply with all required
industrial standards and regulations. In
addition, Panasonic conducts stringent testing
to ensure the reliability of parts and materials.
The strength of the resin material used in a
propeller fan is confirmed by a tension test.
RoHS / REACH compliant parts
All Panasonic parts and materials comply with
Europe’s strict RoHS/REACH environmental
regulations. During the development and
production of parts, stringent inspections are
conducted on over 100 materials to ensure
that no hazardous substances are included.
Sophisticated production process
Panasonic’s air conditioner production lines
employ state-of-the-art factory automation
technologies to ensure products are
manufactured efficiently and with uniformly
high levels of quality and reliability.
Durability
At Panasonic we know the importance of a long service life with minimal maintenance. That’s why we subject our air conditioners to a wide range of
stringent durability tests.
Long-term durability test
To ensure durability and stable operation for
many years, we conduct a long-term
continuous operation test under conditions
that are much more severe than actual
operating conditions.
Compressor reliability test
After the continuous operation test, we remove
the compressor from a selected outdoor unit,
disassemble it, and examine the internal
mechanisms and parts for potential failure.
This helps ensure reliable long-term
performance under harsh conditions.
Waterproofing test
The unit - which is subject to rain and
wind - complies with IPX4 waterproof
specifications. Contact sections on printed
circuit boards are resin-potted to prevent
adverse effects caused by exposure to water
(an unlikely occurrence).
9
PANASONIC: ECO & SMART IDEAS FOR
A SUSTAINABLE LIFESTYLE
10
NEW / EDITORIAL
Panasonic Green Innovation Company.
We will make the environment central to all our business
activities and work to realise our vision with innovations for
both every day life and business.
Exemplary sustainable projects
Fujisawa Sustainable Smart Town Goes Into Full-Scale Operation
Near Tokyo.
Fujisawa SST Council is a consortium led by Panasonic Corporation
spearheading the development of the Fujisawa Sustainable Smart Town
(Fujisawa SST). With its core facility supporting sustainable development
of the town and its community now coming into operation, the Fujisawa
SST is moving from the construction stage into a new stage where the
town is nurtured to grow in full-scale into an eco and smart town that
puts a high priority on the residents’ lifestyles.
The Fujisawa SST Management Company is the town management
company located in the SQUARE. Together with partner companies, the
company provides five essential services in the town: energy, security,
mobility, healthcare and community. The company will also collect and
manage information relating to the town’s overall environment, energy,
security and safety to support an eco and smart life in the town.
As a fresh development in the town, the Fujisawa SST has set a detached
housing zone for non car owners for the second phase of sales. By using
the town’s eco-car sharing and rent-a-car services, residents in the zone
Solar Power Generator.
HIT solar cells achieve maximum output even
on smaller roofs. These solar modules are
100% emission free, have no moving parts and
produce no noise.
Home AV.
Panasonic offers a wide range of energy saving
home equipment to fulfil a sustainable and
comfortable lifestyle.
can enjoy their lifestyles without the need to own a car while reducing
economic burden and making effective use of the lot. Preparations are
also underway for a new base to provide environmentally-friendly logistic
services to the residents.
Heat Pump.
The Aquarea Heat Pump is part of a new
generation of heating systems that use a
renewable, free energy source: air, to heat
or cool the home and to produce hot
water.
Fuel Cell.
The Panasonic Fuel Cell is an energy-creating
device, which generates electricity and heat at
the same time with chemical reaction between
hydrogen extracted from natural gas and
oxygen.
Solar Power Generator.
Our mobility space can be connected
to our HIT solar panels – with the help
from our storage batteries.
LED Lamps.
Expertise gathered over years of research and
development has enabled Panasonic to provide
a renaissance in energy saving home LED
lighting – with our LED Nostalgic Clear lamp.
Home Appliances.
Panasonic is globally committed to develop products
which are environmentally friendly. Panasonic delivers
home appliances such as refrigerators and washing
machines that incorporate the latest energy-efficient
technology.
Storage Battery.
The battery stores the energy generated by a
combination of solar power and fuel cells to
ensure a constant supply of electricity on
demand.
11
PROJECTS & CASE STUDIES OF PANASONIC
HEATING AND COOLING SOLUTIONS
New Hotel Monument 5*GL is located in an 1896 palace.
Barcelona, Spain. ECOi and E-Control
12
NEW / EDITORIAL
Panasonic, a partner with the knowledge and experience to
achieve your objectives and green needs.
Integrated technology that permits better work, easy installation, high efficiency performance, and energy saving
Our main targets are the distributed services and B2B-integrated solutions.
Panasonic provides a single point of contact for the design and maintenance of your system, making things easy for you.
Given our experience in processes, technologies and complex business models, we can offer you effective solutions that reduce costs, whilst also being
efficient, user-friendly, reliable and innovative.
Another advantage we offer to our clients is a support service for systems integration projects, which we provide through our wide range of services and
solutions.
As a global company, we have at our disposal the financial, logistical and technical resources to develop complex and wide-ranging solutions, both at
country and international level by implementing them both on-time and on-budget.
The latest glamorous Burger & Lobster
restaurant in Bath. UK. AQUAREA
Brabrand Boligforening has constructed 75
low-energy houses in Hasselager near Århus
AQUAREA
An water tower has been converted into a
stunning family home. Yorkshire, UK.
AQUAREA
21 of the 5-6 bedroom luxury homes in
Straffan Co.Kildare, Ireland. AQUAREA
Duplex in Boves, CN. Italy. AQUAREA
Make the most of RHI. An off-grid, mediumsized property. Fife, Scotland. AQUAREA
77 house project in Latvia. AQUAREA
Passive House. Tychowo Poland. AQUAREA
A new building, housing 84 apartments in
Cornella de Llobregat, Barcelona. AQUAREA
Carluccios Restaurant in Sheffield. UK.
AQUAREA
New Housing in Rossåsen. Norway. AQUAREA
Panasonic Smart Home. A house with zero
emissions. Tokyo. Japan. RAC-AQUAREA
To find out more: www.aircon.panasonic.eu
13
PRO CLUB. THE PROFESSIONAL
WEBSITE OF PANASONIC
Donwload on
www.panasonicproclub.com
or connect simply with your
smartphone to the PRO Club
using this QR
Panasonic PRO Club (www.panasonicproclub.com) is the online tool which
makes your life easier! You just have to register and a lot of
functionalities are freely available to you, where ever you are, from your
computer or smart phone!
· Print catalogues with your logo and your address
· Download the latest Aquarea designer to define your system and select
the good Aquarea Heat pump.
· Calculate the specs of the Aquarea Air fan coil based on the parameters
of your system
· Get Documents of conformity and all other documents you may need
· Download all the service manuals, end user manuals and installation
manuals
· Know what to do with error codes
· Find out about the latest news first
· Register for training
· Catalogues (Commercial documentation)
· Marketing (Images in high resolution, advertisements, deco guidelines)
· Tools (Professional software, sizing tools…)
· Installers customize leaflets in PDF format with their logo & contact
details
· Energy label generator. Download energy labels of any device in PDF
format
· Heating calculator
· Noise calculator for outdoor unit
· Aquarea Radiator calculator
· Error Code Search by error code or unit ref. Compatible with smartphone
and tablet computer
· Revit / CAD Images / Spec texts
· Access to Pananet, online library of technical documentation
· Download Documents of Conformity and other Certifications
· Commissioning online
Highlighted Features:
· Extensive library of resources
· Tools & Apps for end users. Check availability in your country:
- My Home: sizing wizard for domestic and A2W range
- My Project: Contact form to Panasonic team
- iFinder: Lists of installers displayed by postcode
· Special offers & promotions
· Training PRO Academy
Panasonic has an impressive range of support services for
designers, specifiers, engineers and distributors working in
the heating and cooling markets.
Easy download Panasonic service documentation and
brochures
Energy label generator. Download Energy labels of any
device in PDF format
14
Customise leaflets with your logo & contact details. Save
and print the PDF
Panasonic PRO Club is fully compatible with tablet computer and
smartphone.
Error Code on your smartphone and your PC: Search by
error code or model reference. Online version +
downloadable version for offline use
NEW / EDITORIAL
AQUAREA DESIGNER
This program allows HVAC designers, installers and distributors to identify
the correct heat pump for a particular application from Panasonic’s
Aquarea range, calculate the savings compared to other heat sources and
very quickly calculate CO2 emissions.
Using Panasonic’s Aquarea Designer, projects can be developed simply
and easily, by either using the Quick Design or Expert Design options.
Each allows the user to build up the project data in a simple step-by-step
process and choose to output reports (in either Quick or Large formats) as
HTML files or as print-outs. To create these useful reports, project data is
input, including:
· Heated area
· Heating requirement
· Heating flow and return temperatures
· Climate data (from a simple drop-down menu) including outdoor
temperature
· Type of hot water tank, storage capacity and hot water target
temperature
Panasonic provides bespoke software helping system
designers, installers and dealers to very quickly design
and size systems, create wiring diagrams and issue bills of
quantities at the push of a button.
Aquarea Designer also means saving
Aquarea Designer will calculate the project’s energy costs in terms of hot
water, heating and pumping. It will show the equipment running times and
calculate the COP (coefficient of performance). It then allows the designer
to show clients a comparison with other equipment options such as
heating by conventional gas-fired boilers, oil systems, wood, standard
electric heating and electric night storage heaters. This compares running
costs, initial investment costs and maintenance costs. The comparison
can also be made for CO2 emissions and savings.
The Panasonic PRO Academy
Panasonic takes its responsibility to its distributors, specifiers and
installers seriously and has developed a comprehensive Training
Programme. The Panasonic Pro-Academy encompasses the traditional
hands-on approach to teaching.
New training courses cover three levels. Design, installation, and
commissioning & trouble-shooting. Training courses include:
· Domestic applications Air to Air
· Aquarea air source heat pumps
· VRF ECOi
The courses are offered on site at Panasonic’s premises across Europe.
The Training Centres display Panasonic’s latest product range and give
delegates an opportunity to get a hands-on experience with the latest
controllers, indoor and outdoor units from the VRF ECOi, Etherea, GHP and
Aquarea ranges.
Donwload on
www.panasonicproclub.com
or connect simply with your
smartphone to the PRO Club
using this QR
15
WELCOME TO AQUAREA AIR TO
WATER HEAT PUMP
16
NEW AQUAREA
TECHNOLOGY
NEW / AQUAREA
Aquarea’s new Air to Water Heat Pump for residential and commercial applications.
Offering capacities from 3kW all the way through to 16kW, the Aquarea Heat Pump
Range is the widest on the market, ensuring a system is available, whatever your
heating and cooling needs. Suitable for new build and refurbishment projects, the
solutions are cost-effective and environmentally friendly.
17
HIGHLIGHTED FEATURES
18
NEW / AQUAREA
Panasonic’s Aquarea range of Heat Pumps deliver major
energy savings thanks to its incredible efficiency even at
-20°C. The Panasonic Aquarea Heat Pumps are designed
and produced by Panasonic and not by other companies.
The Aquarea Heat Pump is a system that generates the perfect
temperature and produces hot water, in an easy, cheap and
environmentally friendly way, by transferring heat instead of generating it.
It is among the Technologies listed on the International Energy Agency
(IEA) Blue Map, whose goal is to reduce CO2 emissions to half the levels
emitted in 2005, by the year 2050.
Aquarea is part of a new generation of heating solutions that use a
renewable, free energy source (the air) to heat or cool the home and to
produce hot water:
· Extremely high efficiency (COP of 5,08 for new 5kW Mono‑bloc unit)
· Line up developed for low consumption homes (starting at 3kW)
· T -CAP solution is ideal for cold areas, as it maintains the nominal
capacity up to -15°C
· Easy to control with your smart phone (using an optional interface)
· Large range of efficient tanks for domestic hot water storage
Energy saving
A++
ErP 55°C
Better Efficiency & Value. For
medium temperature applications.
Aquarea systems meets ErP
regulation as A++.
A++
ErP 35°C
Better Efficiency & Value. For low
temperature applications.
Aquarea systems meets ErP
regulation as A++.
A CLASS
A
WATER PUMP
DHW 55°C
Better Efficiency & Value. For low
temperature applications.
Aquarea systems meets ErP
regulation as A.
AUTO SPEED
Aquarea are built-in with A class
water pump. H Generation with
auto speed, and F Generation and
normal G Generation with 7
speeds.
The A Inverter+ system provides
energy savings of up to 30%
compared to non Inverter models.
Both you, and nature, wins!
High Performance
5,08
-15°C
65°C
COP
CONSTANT HEATING
OUTPUT WATER
HIGH PERFORMANCE
T-CAP
HIGH TEMP
Aquarea High Performance for low
consumption houses. From 3 to
16kW. For a house with low
temperature radiators or underfloor heating, our high
performance Aquarea HP is a
good solution.
Aquarea T-CAP for extremely low
temperatures. From 9 to 16kW. If
the most important aspect is to
maintain nominal heating
capacities even at temperatures
as low as -7°C or -15°C, select
the Aquarea T-CAP.
STOP
STOP VALVE
Water stop valve included on
H Generation.
FLOW SENSOR
Water Flow Sensor included on
H Generation.
Aquarea HT ideal for retrofit. From 9
to 12kW. For a house with
traditional high-temperature
radiators, the Aquarea HT solution
is the most appropriate, can work in
output water temperatures of 65°C
even at outdoor temperatures as
low as -20°C.
5
-20°C
DHW
DHW. With Aquarea you can also
heat your domestic hot water at a
very low cost with the optional
hot water cylinder.
HEATING MODE
Down to -20°C in heating mode.
The Heat Pumps work in Heat
Pump mode with an outdoor
temperature as low as -20°C.
WATER FILTER
Water filter (easy access & fast
clip technology) for H Generation.
YEARS
COMPRESSOR
WARRANTY
We guarantee the outdoor unit
compressors in the entire range
for five years.
ehpa
SG Ready: Thanks to Aquarea HPM, Aquarea range (Bi‑bloc and Mono‑bloc) is holding the SG Ready Label (Smart Grid
Ready Label), given by Bundesverband Wärmepumpe (German Heat Pump Association). This Label shows the real
capacity of Aquarea to be connected in an intelligent grid control.
MCS Certificate number: MCS HP0086.*
High connectivity
BMS
BOILER CONNECTION
Renovation. Our Aquarea Heat
Pumps can be connected to an
existing or new boiler for
optimum comfort even at very low
outdoor temperatures.
SOLAR KIT
Solar Kit. For even greater
efficiency, our Aquarea Heat
Pumps can be connected to
photovoltaic solar panels with an
optional kit.
ADVANCED CONTROL
New remote controller with full
dotted 3,5’’ wide back light
screen. Menu with 10 available
languages easy to use for
installer and user. Included on
H Generation.
INTERNET CONTROL
Internet Control is a next
generation system providing a
user-friendly remote controller of
air conditioning or Heat Pump
units from everywhere, using a
simple Android or iOS smartphone,
tablet or PC via internet.
CONNECTIVITY
Connectivity. The communication
port is integrated into the indoor
unit and provides easy connection
to, and control of, your Panasonic
Heat Pump to your home or
building management system.
* Not all products certified. As the
certification process is on-going
and the list of certified products
constantly changing, please check
for latest details on the official
websites.
19
HOW DO YOU GET HEATING AND
DOMESTIC HOT WATER FROM AIR?
20
NEW / AQUAREA
New Aquarea Air to Water Heat Pump, the best seasonal
efficiency.
At the forefront of energy innovation, Aquarea is resolutely
positioned as a “green” heating and air conditioning
solution.
Introducing the Panasonic Aquarea – Air Source Heat Pump
An Aquarea air source Heat Pump circulates fresh air and passes it over
refrigerant-filled coils (like a refrigerator). The captured heat is
automatically transferred to water, which is then ready for use in your
heating system and for supplying all of your domestic hot water needs.
Panasonic’s latest technology offers you a sustainable alternative to oil,
LPG and electric heating systems.
Why Air Source Heat Pumps?
· Heating, cooling and domestic hot water produced with a single system
· Best in terms of efficiency: even at extreme outdoor temperatures
· Environmentally friendly: can be connected to solar panels
· Technology that adapts to each home: extreme low temp, high
temperature, whatever the climate
· Wide range of solutions: floor heating, radiators and fan coils
· Reduced heating bills and maintenance costs
· Reduce your carbon footprint
· Simple to integrate into existing heating systems
· Energy efficient alternative to oil, LPG and electric systems
· Ideal for properties without access to mains gas
· Externally positioned saving valuable internal living space
Up to 80% energy savings*
At the forefront of energy innovation, Aquarea is resolutely positioned as a
“green” heating and air-conditioning solution. Aquarea is part of a new
generation of heating and air-conditioning solutions that use a renewable,
free energy source – the air – to heat or cool the home and produce hot
water. The Aquarea Heat Pump is a much more flexible and cost-effective
alternative to a traditional fossil fuel boiler.
“Green” High-efficiency heating with Panasonic’s new Air to Water
Heat Pump Systems
Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating
expenses compared to electrical heaters. For example, the Aquarea 5kW
system has a COP of 5,28. This is 5,28 more than a conventional electrical
heating system which has a maximum COP of 1. This is equivalent to an
80%* saving. Consumption can be further reduced by connecting
photovoltaic solar panels to the Aquarea system.
Aquarea Air to Water Heat Pump: An innovative low energy
solution, designed to create great comfort at home even at
extreme outdoor temperatures. Providing heat to radiators,
underfloor heating, fancoils as well as producing domestic
hot water.
Aquarea up to 80% energy savings*
A++
0,80kW
Gas
Oil
Heat
1,00kW
0,90kW
Power Input /
Energy Consumption
Power Output /
Heating Capacity
Gas boiler
Oil boiler
Power Input /
Free Energy
Electricity
Heat
1,00kW
1,00kW
Renewable
Energy
Electrical
heating
Electricity
0,20kW
Heat
1,00kW
* Up to 80% of the heat produced by a Heat Pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb /
Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30°C Water output temperature: 35°C
21
AQUAREA HEAT PUMP LINE-UP
6
5
2
1b
3
4
1a
1c
22
1a
1b
1c
2
3
4
5
6
Mono‑bloc
system
Bi‑bloc
system
All in One
system
Aquarea Heat
Pump Manager
(optional)
Control through
smart phone,
tablet or
computer
(optional)
Super High
Efficiency
cylinder
(optional)
High efficient
radiators for
heating and
cooling
(optional)
Heat Pump +
HIT Photovoltaic
solar panel
(optional)
NEW / AQUAREA
Panasonic Aquarea offers you solutions, helping to make
the home more efficient and the installation cheaper and
easier.
Aquarea High Performance. For new installations and low
consumption homes
Maximum savings, maximum efficiency, minimum CO2 emissions,
minimum of space. Improved performance with COP’s up to 5,28.
Aquarea HT. For a house with old high-temperature radiators
Ideal for retrofit: green energy source works with existing radiators.
Aquarea HT Solution is the most appropriate, provides output water
temperatures of 65°C even at outdoor temperatures as low as -15°C.
Aquarea T-CAP. For extremely low temperatures, refurbishment
and innovation
Ideal to ensure that the heating capacity is maintained even at very low
temperatures. This line-up is able to maintain the Heat Pump output
capacity until -20°C outdoor temperature without the help of an electrical
booster heater.
Aquarea DHW
DHW tank with built-in Heat Pump.
Aquarea High Performance
Aquarea T-CAP
Aquarea HT
Aquarea DHW
Heating - Cooling - DHW
Single Phase from 3 to 16kW
Three Phase from 9 to 16kW
Heating - Cooling - DHW
Single Phase from 9 to 12kW
Three Phase from 9 to 16kW
Heating - DHW
Single Phase from 9 to 12kW
Three Phase from 9 to 16kW
Only DHW
From 80 to 295L
Connectable to
Radiators - Fancoil - Underfloor heating - DHW Radiators - Fancoil - Underfloor heating - DHW Traditional high-temperature radiators - DHW
Application
Normal installation
For extreme cold ambient
Retrofit for old radiators
Domestic hot water
Only DHW
Energy efficiency
A++
A++
Heating 35°C / 55°C
-28°C
75°C / 55°C
Smart Grid Ready²
Wifi Ready
Bi‑bloc from 3 to 16kW
Mono‑bloc from 5 to 16kW
All in One from 3 to 16kW (185L)
A++
A++
A++
A++
Heating 35°C / 60°C¹
Heating 35°C / 55°C
Outdoor ambient temperature limit. Operation
-28°C
-28°C
Outdoor ambient temperature limit. Constant capacity
-15°C / -20°C¹
-15°C
Supply temperature for heating. Max. / Heat pump only
75°C / 60°C¹
75°C / 65°C
Control and connectivity
Smart Grid Ready²
Smart Grid Ready²
Wifi Ready
Wifi Ready
Range
Bi‑bloc from 9 to 16kW
Bi‑bloc from 9 to 12kW
Mono‑bloc from 9 to 16kW
Mono‑bloc from 9 to 12kW
All in One from 9 to 16kW (185L)
A
DHW 55°C
-7°C
75°C / 55°C
Smart Grid Ready²
Wifi Ready
From 80 to 295L
All data in this chart is applicable in most of models in each line up, check product specs to confirm. 1) H Generation T-CAP. 2) H Generation with CZ-NS4P, F and G Generation with Heat Pump Manager.
23
NEW AQUAREA H GENERATION A+++
24
NEW / AQUAREA
The beauty of comfort. The new H Generation is being
introduced from 3 to 16kW. The small capacities are
specially designed for low energy homes and achieve an
impressive COP of 5 (on the 3kW).
FREE
MAINTENANCE
STAINLESS TANK*
* FOR ALL IN ONE H GENERATION
Better Efficiency & Value A++/A++
· A++ for medium temperature applications (radiators. ErP 55°C)
· A++ for low temperature applications (floor heating. ErP 35°C)
· 3 & 5kW meet Sep’19 ErP regulation as A+++
Aquarea, a new generation of energy efficient heating and hot water
Thanks to the system’s high degree of technology and advanced control, it
is able to maintain a high output capacity and efficiency even at -7°C and
-15°C. The Aquarea’s software can be set for the requirements of low
consumption homes in order to maximise energy efficiency. Whatever the
weather, Aquarea can work even at -20°C. The compact design of the
outdoor unit makes installation very easy.
New Design
New improved square design with white goods finish. Modern remote
controller can be installed up to 50m from the indoor unit.
Installer Friendly:
· Electrical connections is now located on front side
· E asy access to parts and easy to install by having all pipings in a row
· N ew remote controller with full dotted wide screen and new functions
· Can connect additional room temperature sensor, solar kit, 2 zones control,
swimming pool and circulating pump (need optional PCB: CZ-NS4P)
Compact and free space. More value in 1 compact space:
· Line strainer (easy access & fast clip technology)
· Isolation valves
· Electronic flow sensor
· 3 way valve ready (optional CZ-NV1 in internal space)
New All in One with 2 zones control
· 2 heating circuits, with 2 different water temperatures
· 2 water pumps and 2 water filters
· F loor heating water control with mixing valve
2 Zones kit included with control of 2 water temperatures
(underfloor with water at 35°C and radiators with water at 45°C)
NO
BUFFER
TANK
New Aquarea H Generation
Bi‑bloc or All in One system
New All in One, compact and easy to install
Space-saving solution ideal for installations with restricted space. In
addition, Panasonic has developed bivalent and cascade systems that give
the user control of two heating zones.
The Aquarea All in One belongs to the new generation of Panasonic heat
pumps for heating, cooling and providing domestic hot water in the home.
Aquarea T‑CAP is one of the newest heat pumps on the market,
maintaining nominal heating capacities even at temperatures as low as
-20°C*. This ensures the best possible seasonal energy efficiency ratio.
The heat pumps are tested at an outdoor temperature of -28°C to ensure
the most efficient and stable operation.
BEST IN TEST 2016: * Applies to All in One T-CAP 5kW H Generation: The highest measured SCOP (energy efficiency) of all air/
water heat pumps, in the corresponding category, that have been published on the heat pump list of the Danish Energy Agency:
sparenergi.dk/forbruger/vaerktoejer/
New Aquarea Smart Cloud for H Generation
The most advanced heating control for today and for the future:
Easy and powerful energy management. The Aquarea Smart Cloud is much
more than a simple thermostat for switching a heating device on or off.
It is a powerful and intuitive service for remotely controlling the full range
of heating and domestic hot water functions, including monitoring energy
consumption, Malfunction notification, Failure Prediction & Remote
Servicing as some options.
Advanced Control
Ease of use: New remote controller with full dotted 3,5’’ wide back light
screen provides clearer visibility to the user.
Relocation: Remote controller can be installed up to 50m from the
indoor unit.
New Accessory
Optional PCB (CZ-NS4P). With this new PCB you can also manage one or
more functions like below: SG Ready, 0‑10V demand signal, 2-zones control
function (pump + mixing valve), solar and external switch (heat / cool).
25
AQUAREA HIGH PERFORMANCE
26
NEW / AQUAREA
For new installations and low consumption homes.
Maximum savings, maximum efficiency, minimum CO2
emissions, minimum of space.
High Performance helps you to meet strict building requirements and reduce building costs
The heating and production of domestic hot water have a very important impact on the energy consumption of a house. Efficient Panasonic Heat Pumps can
help to significantly reduce the energy consumption of the house.
Standard circulating pumps vs “A”
Class circulating pumps
Comparison of energy consumption of
circulation pumps.
New “A” Class circulating pump with
Dynamic flow control for 5kW Mono‑bloc.
* Based on German market: Assuming Standard pump may vary depending
on consumption and energy cost.
Equivalent to
€/year
saving*
100
75W
Standard
pumps
47W
Aquarea
“A” Class
COP
Heating capacity
6,00
6,00
5,00
5,08
4,00
5,00
5,00
4,50
4,00
4,80
5,00
3,75
At +7°C*
0
At +2°C*
1,00
At -7°C*
0
At +7°C*
1,00
2,00
At +2°C*
2,00
3,00
3,00
2,56
At -15°C*
3,00
At -7°C*
Panasonic has designed the new Aquarea Bi‑bloc and
Mono‑bloc Heat Pumps for homes which have high
performance requirements.
Whatever the weather, Aquarea can work even at -20°C!
The New Aquarea is easy to install on new or existing
installations, in all types of properties.
High Performance Pumps are also Highly Efficient
(take the WH-MDC05F3E5 for example)
At -15°C*
Key points of the line-up
· Improved performance with COP’s up to 5,08
· R educed energy consumption through our “A” Class circulating pump
· R emote controller functions added: Auto mode, holiday mode, power
consumption display
* Heating water at 35°C.
Panasonic created a night mode
to reduce the noise when it’s
needed
Special attention has been given to
noise levels
Noise level dB(A)¹
1. Sound pressure measured at 1m from the outdoor unit and at
1,5m height.
2. At standard condition working at heating capacity at +7°C
(heating water at 35°C) for two fans outdoor units. For one
fan outdoor units, night mode reduction is 3dB(A).
20
50
-5dB(A)²
40
30
10
Normal
mode
Panasonic
Quiet
Mode²
0
Advanced Controller for H Generation
Improved visibility & Easy operation with large
full dot LCD display and large touch panel!
Remote controller can be removed from indoor unit and
installed in living room.
Key Points:
Full large dot LCD screen (3,5 inch): High resolution screen with backlight,
easy set up, check conditions easily, flat, innovative design, temperature
sensor included in controller.
Remote controller
Panasonic has introduced a new remote controller to improve performance, enhance comfort and deliver maximum savings.
New function for installer:
· F loor heating concrete dry mode: Allows for a slow increase in
temperature of underfloor heating via software.
· H eating and Cooling Mode: Authorised PRO Partners can enable the
cooling mode through a special operation via the remote controller on
site
· C irculating pump speed can be selected on the remote controller
· P ump speed is selected automatic based on demand
New function for End User:
· Auto Mode: Automatically changes from heating to cooling depending on
outdoor temperature.
· Energy Consumption Display: Displays the Heat Pump’s energy
consumption, split by heating, cooling and domestic hot water, showing
the total consumption figure.
· Holiday Mode: Enables the system to resume at the preset temperature
after your holiday
27
AQUAREA T-CAP
28
NEW / AQUAREA
For retrofit and new builds, install the T‑CAP heat pump
where the kW output capacity is demanding.
Ensure the heating capacity is maintained even at low
temperatures
The whole T-CAP line-up can replace old gas or oil boilers, and in a new
application with underfloor heating, radiators or even fan-coil heaters, the
whole T-CAP line-up is an ideal replacement for old gas/oil boilers. All
Aquarea heat pumps can also be connected to a solar thermal or PV
system in order to increase efficiency and minimise the impact on the
ecosystem.
Key points of the line-up
· Ability to maintain the heat pump kW¹ output capacity until -20°C
outdoor temperature without the help of an electrical booster heater
· High heating capacity even at low ambient temperatures
· Additional functions: Auto and holiday mode, boost, drying concrete and
power consumption display
· Backup heater capacity can be selected depending on the model (3/6/9kW)
· Cooling mode activation possible via software²
1) At 35°C flow
2) This activation can only be done by service partner or installer
Best efficiency compared to other heating systems
Panasonic Heat Pumps have a maximum COP of 4,85 at +7°C which
makes them much more efficient than others heating systems.
COP
5,00
4,85
4,00
3,00
3,07
2,85
2,00
0,85
0,90
Fuel fired boiler
Gas boiler
T-CAP 9kW at -7°C
Water 55°C
0
Water 35°C
1,00
Water 55°C
Water 35°C
2,11
T-CAP 9kW at +7°C
More Energy saving
T-CAP is also able to provide extremely high efficiencies, whatever the
outside or the water temperature.
With a Panasonic heat pump, there is no need to oversize in order
to reach the required capacity at low temperatures
· Panasonic’s unique software and inverter technology for low consumption
houses, allows the heat pump to produce heating water at 20°C. When
only a little heating is required due to warmer outside air temperature
· All Aquarea heat pump’s have a 10L expansion vessel fitted internally
· Aquarea heat pump’s has an inverter compressor which can regulate the
output capacity depending on demand
· New twin dice system included within the system (Twin fan outdoor unit)
· 3/6/9kW electrical heater is included in the heat pump (depending on unit)
· Panasonic heat pumps can work in outdoor temperatures as low as -28°C
and guarantee the capacity without backup heating down to -15°C¹
· Panasonic heat pumps are very quiet and have a noise reduction setting
for night mode. See noise calculator on www.panasonicproclub.com
1) 35°C flow temperature.
Other Heat Pumps need
electrical heater to cover the
demand of the house
Heating capacity
The capacity of other heat
pumps needs to be higher than
the Panasonic heat pumps
Panasonic Heat Pump does not need
heater as the capacity is maintained. The
capacity is stable even at -15°C, no need
to oversize the heat pump
18,00
16,00
14,00
-20°C
-15°C
-7°C
+2°C
Outdoor temperature (heating water at 35°C)
High Connectivity 16kW
T-CAP 16kW
High Connectivity 16kW
T-CAP 16kW
0
High Connectivity 16kW
2,00
T-CAP 16kW
4,00
T-CAP 16kW
6,00
T-CAP 16kW
8,00
High Connectivity 16kW
10,00
+7°C
Capacity in kW
16kW T-CAP
12,00
-20°C
Capac
ity ne
-15°C
Bad performance
to big capacity
mp
at pu
r he
Othe
-7°C
Outdoor temperature
eded
to he
at the
+2°C
· High flexibility
with Panasonic
Inverter
compressors
· High
Performance
even at part
load
house
+7°C
Applications
For retrofit houses. Easy to
replace expensive gas or oil
boilers for high efficient 16kW
T‑CAP.
For commercial applications.
Wide range of capacities from
9kW to 45kW. Also you are able
to connect up to five Heat Pumps.
For heating and cooling mode. The
16kW is able to heat the water at
60°C and can work when the
temperature is as low as -28°C.
For heating and domestic hot
water. Efficient domestic hot water
tanks allow large storage for high
consumption of hot water.
29
AQUAREA HT
30
NEW / AQUAREA
Aquarea HT can produce a flow temperature of 65°C making
it the ideal high efficiency replacement for oil/gas boilers
connected to high temperature radiators.
Green energy source works with existing radiators
The Aquarea HT (9kW & 12kW) allows you to replace your traditional
heating source (such as oil or gas) while keeping the existing old style
radiators for minimum disruption to the home.
Aquarea HT: High savings and low CO2
The benefit of replacing a traditional heating systems with Aquarea HT are
clear: Reduced CO2 emissions, future proofing running costs.
Panasonic Heat Pumps are much more efficient than fossil fueled boilers
and help you to reach your house energy targets.
Smart Bivalent operation
Using the Aquarea bivalent controller,
it is now possible to combine different
heat sources (boiler with heat pump)
allowing to set up the system to
operate in the most efficient way.
Heat Pump + Boiler with DHW cylinder controlled by the smart
bivalent controller.
Yearly savings with Aquarea HT
Euro/Year
Running Costs*
2.000
1.500
1.000
500
0
Panasonic Heat Pump
Oil
Easy installation
Air source Heat Pumps are simple to install. They do not require a
chimney, gas connection or oil/lpg tank. All that is required is a power
supply connection.
Gas
* For a 170m² house and 40 W/m² energy losses in central Europe Conditions, outside minimum conditions -10°C.
Panasonic Aquarea HT is highly efficient even at low outdoor temperatures
Heating Capacity of a 9kW HT (WH-SHF09F3E5).
COP (Coefficient of Performance) of a 9kW HT (WH-MHF09G3E5).
kW
COP
9,00
5,00
8,00
4,00
7,00
6,00
3,00
5,00
4,00
2,00
-15°C
-2°C
+2°C
Heating capacity of a 9kW HT at 35°C flow
+7°C
-15°C
-2°C
+2°C
Heating capacity of a 9kW HT at 35°C flow
Water 65°C
Water 55°C
Water 35°C
Water 65°C
Water 55°C
Water 35°C
Water 65°C
Water 55°C
Water 35°C
0
Water 65°C
1,00
Water 55°C
Water 65°C
Water 55°C
Water 35°C
Water 65°C
Water 55°C
Water 35°C
Water 65°C
Water 55°C
Water 35°C
Water 65°C
0
Water 55°C
1,00
Water 35°C
2,00
Water 35°C
3,00
+7°C
The Aquarea HT range is easy to install and is available with nominal heat outputs of 9kW or 12kW. These can be either
single or three phase, in both Bi-bloc and Mono‑bloc versions. The HT is also very quiet in operation with minimal noise
inside the house due to no double stage compression cycle.
31
AQUAREA COMMERCIAL
4
1
3
2
7
5
6
7
8
3
1
2
6
32
5
NEW / AQUAREA
Solutions for best savings. Efficient Panasonic Heat Pumps
can help to significantly reduce the energy consumption
of your business. Recent improvements to air source Heat
Pump technology, including compact single unit systems,
can provide an ideal housing and commercial solution.
They offer space saving, energy-efficient heating and can be easily
adapted for installation in flats, houses and commercial premises.
Businesses producing heat, such as restaurants, installing an Aquarea
Heat Pump system can also use this wasted heat to improve energy
efficiency further.
Restaurant with Aquarea
If you are looking for savings for your business, Aquarea is the right
choice! Ideal for heating, cooling and for production of big quantities of
hot water at 65°C, Aquarea have a extremely quick return on investment
and a low CO2 footprint.
Key points:
· Produce hot water efficiency
· Fast return of investment
· Easy control
· Cascade management for higher durability of the system
Aquarea T‑CAP.
Heat Pump 16kW on cascade mode.
5
Super high efficiency Tanks.
From 200L to 500L for domestic hot
water.
Can be integrated in the water system.
Easy connection to existing system
· Fan Coils
· Floor Heating
· 4 way and 2 way convectors
· Domestic hot water tanks
· High efficiency
· Very good part load management
· Cascade management for higher durability of the system
* 1 HPM can control 3 HP, on this case 2 HPM are needed
* 1 HPM can control 3 HP, on this case 2 HPM are needed
1
Supermarket with Aquarea
Heat pump technology is scalable, meaning that it can be installed in
buildings of varying sizes, offering both small- and large-scale heating
solutions. The technology is also environmentally friendly when compared
to existing technologies, offering demonstrable energy-use and emissions
savings and in most cases; will deliver operational cost savings when
compared with fossil fuel alternatives.
2
High Efficiency Aquarea Hydrokit.
6
Buffer Tank of 1.000L.
Case study: Carluccio’s restaurant
On of UK’s leading Italian restaurant, Carluccio’s, wanted to install a
system which would provide the desired volume of hot water, at the
correct temperature while at the same time reduced energy costs.
Previous restaurants in the chain had been fitted with a more traditional
12kW boiler system.
FWP installed a 12kW Aquarea T‑CAP mono bloc unit which would allow
for the free air from the kitchen roof space to be transferred through
3
HPM to control the Heat Pumps on
cascade mode*.
7
Air Curtain with DX Coil.
Designed for smooth operation and
efficient performance.
4
High efficiency Aquarea Air radiators.
32% more efficient than standard
radiators.
8
Convectors.
condensing unit providing hot water at the optimum temperature. With a
high coefficient of performance (COP), the system returns an impressive
4kW of energy, for every kW used. This makes the Aquarea far more cost
effective than a conventional heating system. To heat the water for their
Leeds restaurant cost £3782 whilst at the Meadowhall site the
comparable cost was just £951. These sizeable savings mean the site will
see a return on investment in approximately 2 years.
33
NEW AQUAREA SMART CLOUD
FOR H GENERATION
The most advanced heating control for today and for the future
Easy and powerful energy management.
The Aquarea Smart Cloud is much more than a simple thermostat for
switching a heating device on or off. It is a powerful and intuitive service
for remotely controlling the full range of heating and hot water functions,
including monitoring energy consumption.
New functions for maintenance companies will be added during 1st Half
of 2018 making advanced remote maintenance available to users and
companies using any device.
* User interface image
may change without
notification.
How it works?
Connect Aquarea H Generation system to the cloud using wireless LAN or
a wired LAN Network. User connects to the Cloud portal to remotely
operate all unit functions and can also permit partners to access
customised functions for remote maintenance and monitoring.
See demo: https://aquarea.aircon.panasonic.eu
Requirements:
1. H Generation Aquarea system
2. In-house internet connection with router wireless LAN or wired LAN
3. Get a Panasonic ID in https://aquarea-smart.panasonic.com/
2 step introduction with same hardware: CZ-TAW1
Step 1
Advantages
Energy savings, comfort and control from anywhere. Increase efficiency
and resources management, operating costs savings and owner
satisfaction. Throughout 2018 Panasonic will add new services to the
Aquarea Smart Cloud focused on enabling full remote maintenance of the
Aquarea system. This will allow maintenance specialists to engage in
predictive maintenance and system fine-tuning, as well as fixing
malfunctions when they occur.
Aquarea compatibility
H Generation
Connection point
CN-CNT Aquarea port
Home router connection
Wireless or Wired LAN
Temperature sensor
Can use remote controller sensor
Tablet or PC browser compatibility*
Yes
Operation from remote — On/Off — House Temp setting
mode selection — DHW setting — Error codes ­—
Yes
Scheduling
Heating areas
Up to 2 zones
Power consumption estimation ­— Operation log history Yes — Yes
* Check browsers and version compatibility.
34
Step 2 (during 2018)
Same CZ-TAW1 hardware. Changes
implemented in the cloud server.
End User management and energy control
✔
Visualization & Control
—
✔
Scheduling
—
✔
Energy Statistics
—
✔
Malfunction notification
—
Advanced functions for remote maintenance with professional screens¹
✔
Monitoring
—
✔
Control
—
✔
Statistics (exportable)
—
✔
Remote Service
—
1) Advanced functions not confirmed, final ones might differ from this list.
1
1. LAN
2. Aquarea connection by CN-CNT
2
NEW / AQUAREA
CONTROL & CONNECTIVITY
Home connectivity and Home Managements Systems integration is
becoming more and more popular. These integrations helps to control all
house devices from centralised platform and helps to optimise the
operation and running costs. Panasonic interfaces are made to work with
both Modbus and KNX, the most populars protocols. Also for non
integrated control, Panasonic developed a simple connection to Wireless
LAN, with this End User can control remotely its own heat pump from
wherever.
Internet Control
What’s Internet Control?
Aquarea heat pumps can be connected to Internet thru wireless LAN.
When connection is done unit can be controlled from wherever and
whenever with just Computer or Smartphone. Offering full system
operation and error code messages, CZ-TAW1 offers full scheduling and
powerful consumption stats. This device is ready for future improvements
in the server, bringing advanced new functions for remote maintenance.
This advanced features will bring quicker service to user and time savings
to installers and maintenance companies.
Connectivity. Control by BMS
Great flexibility for integration into your KNX / Modbus projects allows fully bi-directional monitoring and control of all the functioning parameters.
Interface to connect Aquarea to KNX.
Reference: PAW-AW-KNX-1i / PAW-AW-KNX-H.
These new interfaces allows full monitoring and control, bi-directional, of
all the functioning parameters of Aquarea control from KNX installations.
· Small dimensions. / Quick installation and possibility of hidden
installation
· External power not required
· Direct connection to the unit
· Fully KNX interoperable: Control and monitoring, from sensors or
gateways, of the internal variables of the indoor unit and error codes
and indication
· Aquarea unit can be controlled simultaneously by its remote controller
and by KNX Master devices
Interface to connect Aquarea to Modbus.
Reference: PAW-AW-MBS-1 / PAW-AW-MBS-H.
These new interfaces allows full monitoring and control, bi-directional, of all
the functioning parameters of Aquarea control from Modbus installations.
· Small dimensions. / Quick installation and possibility of hidden
installation
· External power not required
· Direct connection to the unit
· Fully Modbus interoperable: Control and monitoring, from any BMS or
PLC Modbus Master, of internal variables of the indoor unit and error
codes and indication
· Aquarea unit can be controlled simultaneously by its remote controller
and by Modbus Master devices
Model name
PAW-AW-KNX-H
PAW-AW-MBS-H
PAW-AW-KNX-1i
PAW-AW-MBS-1
PA-AW-WIFI-TE1
CZ-TAW1
Interface
KNX interface for H Generation
Modbus interface for H Generation
KNX interface (not compatible with H Generation)
Modbus interface (not compatible with H Generation)
Intenet control Wifi connection (not compatible with
H Generation)
Aquarea Smart Cloud, H Generation Internet control through
Wifi or wired LAN
35
REMOTE CONTROLLER
ADVANCED CONTROL
Advanced controller for H Generation
Improved visibility & easy operation by full dotted LCD panel and
large touch panel!
Remote controller can be removed from indoor unit and installed in living
room.
Key Points:
· Full dot big LCD screen (3,5 inch)
· High resolution screen with backlight
· Easy set up
· Check conditions easily even at the living room
· Flat, innovative design
· Temperature Sensor included in controller
1
10:34am, Mon
2
23 44
˚c
2
1
40 ˚c
˚c 18 ˚c
4
5
6
1. Quick Menu button (For more
details, refer to the separate Quick
Menu Guide)
2. Back button. Returns to the
previous screen
3. LCD Display
4. Main Menu button. For function
setup
5. ON/OFF button. Starts/Stops
operation
6. Operation indicator. Illuminates
during operation, blinks during
alarm
Remote controller for F and G Generation
Panasonic has introduced a new remote controller to improve
performance, enhance comfort and deliver maximum savings.
New function for installer:
· Floor heating concrete dry mode: Allows slow increase in temperature of
floor heating via software
· Heating and Cooling Mode: Authorized service partner or Authorized
installer can enable the cooling mode through a special operation via
the remote controller on site
· Pump with 7 speeds: Pump speed can be selected on the remote controller
New function for end user:
· Auto Mode: Automatically changes from
heating to cooling depending on outdoor
temperature.
· Energy Consumption: Displays the heat pump’s
energy consumption, split by heating, cooling
and domestic hot water, and shows total
consumption figure
· Holiday Mode: Enables the system to resume
at the preset temperature after your holiday
36
New Remote controller
changing point.
Better user interface:
1. Adding Holiday Mode
2. Adding Power Consumption
LCD display:
1. Expand LCD display to show mode on
left and right side
2. Adding AUTO mode and remove
defrost display (using heat blink)
3. Change not available into EXT SW
OFF
4. Adding kWh and Hr
Button:
5. Adding holiday button
6. Change force and error reset position
Temperature
3
1
3
1
2
4
6
5
· 1 stage for 1 day (maximum 99 stages)
· Min 25°C to 55°C
Day
6
NEW / AQUAREA
HEAT PUMP MANAGER
Connected to a router, all information of the heating system controlled by
the HPM is available via the internet. Installers, service companies and
end-users can monitor the installation remotely.
Panasonic has developed a new easy start up mode for the HPM. Start
your bivalent system in just 10 minutes!
Easy Installation & Easy Configuration
Ready: Pre-programmed with up to 610 applications/system diagrams
Steady: At start up - state the number of application/system diagram
Go: The controller starts working according to selected diagram
The next generation of Aquarea Manager
This new generation of smart controllers for eco-efficient heating features
our versatile stand-alone controller for heating and domestic hot water.
Panasonic offers:
Trends. Statistics. Consumption Energy Management-Optimization. Alarm.
Handling + Maintenance. Complete documentation etc.
With or without built-in display
Optional. External touch display with
the Heat Pump Manager
Key points:
· Easy selection with the “ready to go” system
· Up to 610 preconfiguration installations available on
www.panasonicproclub.com
· Cascade system possible for big installations
· Bivalent control in order to also manage gas boilers
· Able to control 2 mixed heated zones
· Smart grid ready
· Solar panel mode in order to produce heat when the PV is generating
electricity
· Online access with control of all parameters
· Easy installation, needing less than 3 minutes to configure a complex
system
Technical Specification:
· New function: Smart Setup
· Control of 2 x Mixed Heating Circuits
· Floor screed dry program
· Cascade/bivalent controller
· Automatic switch from heating to cooling mode
· Night shift: - Internal Energy Manager
· Solar collector control
· Domestic hot water priority
· Easy to startup – easy to operate
· 7 output relays
· 0-10 V In/Output Signal
· 8 Sensor inputs (PT1000)
· USB interface (upload, service, remote controller, trend)
· RS485 interface (com. with additional heat pump)
· RS485 interface (for external display)
· Built-in backlit text display
Easy mounting.
Simple mounting without screws in the cabinet/door or on DIN-rail. Also
possible to mount directly on to the wall.
37
AQUAREA + PV PANELS
Key points:
· Increases the amount of self-consumed electricity from the solar
system up to 120%
· Control the heat pump’s energy consumption according to the output of
electricity from the PV considering the electric energy consumption
requirement of the house
For F and G Generation
Panasonic has developed an innovative algorithm for its HPM (Heat Pump
Manager) which drastically improves the Heat Pump’s use of
selfgenerated electricity from connected Photovoltaic panels. The Heat
Pump will take the electricity generation by the solar system into
consideration for the heating system and the domestic hot water
production, without reducing comfort in the house.
+
PV Panel + Inverter
38
For H Generation
Aquarea H Generation can synchronize with PV panel with simple CZ-NS4P
PCB. A part of converting Aquarea in Smart Grid Ready, there is a new
advantage, this new PCB allows 0-10V control.
With this Aquarea demand is adapting all moment with the PV Panel
production.
+
Heat Pump Manager
=
· Innovative algorithm balancing the heat pump’s consumption and the
in-house comfort, based on the outside temperature and the energy
demand of the building
· Easy configuration of the Heat Pump manager system with the PV
system
Smart Grid Ready
+
Aquarea F/G Generation
PV Panel + Inverter
=
Aquarea H Generation with CZ-NS4P
Smart Grid Ready
and 0-10V control
NEW / AQUAREA
Produce and heat Domestic Hot Water for free.
Comparison on new housing.
Increase usage of self production by: 120%
The Panasonic Aquarea PV Control could increase the energy consumption
of the heat pump coming from the Photovoltaic Panels from 352kWh to
775kWh a year. Results of simulations:
Comparison on old housing.
Increase usage of self production by: 71%
The Panasonic Aquarea PV Control could increase the energy consumption
of the heat pump coming from the Photovoltaic Panels from 526kWh to
898kWh a year. Results of simulations:
New building Frankfurt (non-optimized).
Old building Frankfurt (non-optimized).
New building Frankfurt (optimized-eco).
PV Production (5.630kWh/a)
73% (4.129kWh/a)
27% (1.502kWh/a)
(Energy)
To Grid
(4.129kWh)
(Energy)
To Grid
(3.706kWh)
33% (1,149 kWh)
14% (352 kWh)
33% (1,149 kWh)
67% (2,351 kWh)
86% (2,116 kWh)
67% (2,351 kWh)
Usage of energy in the house
(Energy)
From Grid
(4.467kWh)
PV Production (5.630kWh/a)
66% (3.706kWh/a)
34% (1.924kWh/a)
(Energy)
From Grid
(4.012kWh)
Old building Frankfurt (optimized-eco).
PV Production (5.630kWh/a)
64% (3.583kWh/a)
36% (2.047kWh/a)
(Energy)
To Grid
(3.583kWh)
32% (775 kWh)
33% (1,149 kWh)
12% (526 kWh)
33% (1,149 kWh)
22% (898 kWh)
62% (1,661 kWh)
67% (2,351 kWh)
88% (3,709 kWh)
67% (2,351 kWh)
78% (3,276 kWh)
Usage of energy in the house
Conditions:
Installed PV Capacity: 5,64kWp
Household Consumer Demand: 3.500kWh/a
Hotwater Demand: 200l/day @ 45°C
Insulation Standard (Heat demand): 35kWh/m²
Controller: Non-Intelligent
Consumption of the house
(Energy)
To Grid
(3.955kWh)
PV Production (5.630kWh/a)
70% (3.955kWh/a)
30% (1.675kWh/a)
Conditions:
Installed PV Capacity: 5,64kWp
Household Consumer Demand: 3.500kWh/a
Hotwater Demand: 200l/day @ 40°C
Insulation Standard (Heat demand): 35kWh/m²
Controller: ECO
Usage of energy in the house
From Grid
(6.060kWh)
Conditions:
Installed PV Capacity: 5,64kWp
Household Consumer Demand: 3.500kWh/a
Hotwater Demand: 200l/day @ 45°C
Insulation Standard (Heat demand): 80kWh/m²
Controller: Non-Intelligent
PV: Production of energy
Usage of energy in the house
From Grid
(5.627kWh)
Conditions:
Installed PV Capacity: 5,64kWp
Household Consumer Demand: 3.500kWh/a
Hotwater Demand: 200l/day @ 40°C
Insulation Standard (Heat demand): 80kWh/m²
Controller: ECO
PV: Production of energy
Consumption of the HP
PV + HP control
How to create added value of the combination PV+HP?
· O ptimize the HP considering the PV production
· When
the PV is producing enough to cover the HP consumption, then
Tank mode will be forced to heat up the DHW to 55 or 65 degrees
· If buffer tank on the installation, temperature on the buffer tank will
increase 1-to 5 degrees or up to 55°C.
Photovoltaic
solar panels
Electrical meter
Inverter
Electrical meter
Electrical panel
HPM
Grid
Electrical panel
Home
appliances
and lighting
Heating
and DHW
Standard combination PV+HP. Why the Panasonic Aquarea PV Control can increase by 120% the performance of the combination PV+HP.
Typical Electricity consumption and production profile without Panasonic Aquarea PV Control.
Typical Electricity consumption and production profile optimize by the Panasonic Aquarea PV Control.
Temperature in the house : 21°C +/- 2°C
kW
-4,0
-3,0
-2,0
-1,0
0
1,0
2,0
3,0
4,0
Temperature in the house : 21°C +/- 2°C
kW
-4,0
-3,0
-2,0
-1,0
0
1,0
2,0
3,0
4,0
0:00
Electricity used by
the HP
12:00
Electricity used by
the house and the HP
24:00
No optimization of the consumption of the HP,
production and consumption only match on 13 %
PV production used in the
house and by the HP
PV production send to
the grid
0:00
12:00
By forcing the HP to run when there is production. The
Panasonic Aquarea PV Control increases the consumption
of free electricity coming from the PV by 56%
The HP does not have to work when there is high demand of
electricity during the evening for example
24:00
The house temperature is maintained, to
ensure comfort. A variation of 1 to 2°C
can be programmed in order to increase
the performance of the system
39
AQUAREA HEAT PUMPS LINE-UP
3kW
Aquarea High Performance
for well insulated houses
All in One
Single Phase
Three Phase
Heating, cooling and DHW
Bi‑bloc
Single Phase
Three Phase
Heating and cooling
Mono‑bloc
Single Phase
5kW
WH-ADC0309H3E5
WH-ADC0309H3E5B
WH-UD03HE5-1
WH-ADC0309H3E5
WH-ADC0309H3E5B
WH-UD05HE5-1
WH-SDC03H3E5(-1)
WH-UD03HE5(-1)
WH-SDC05H3E5(-1)
WH-UD05HE5(-1)
Heating and cooling
WH-MDC05H3E5
WH-MDC05F3E5
Aquarea T‑CAP High
Capacity for cold areas
All in One
Single Phase
Three Phase
Heating, cooling and DHW
Bi‑bloc
Single Phase
Three Phase
Heating and cooling
Mono‑bloc
Single Phase
Three Phase
Heating and cooling
Bi‑bloc
Single Phase
Three Phase
Heating only
Mono‑bloc
Single Phase
Heating only
Aquarea HT for retrofit
WH-__E5 Single Phase // WH-__E8 Three Phase. 1) All in One G Generation model. 2) Hydrokit F Generation model.
40
NEW / AQUAREA
7kW
9kW
12kW
16kW
WH-ADC0309H3E5
WH-ADC0309H3E5B
WH-UD07HE5-1
WH-ADC0309H3E5
WH-ADC0309H3E5B
WH-UD09HE5-1
WH-ADC0916H9E8
WH-UD09HE8
WH-ADC1216H6E5
WH-UD12HE5
WH-ADC1216G6E5¹
WH-UD12FE5
WH-ADC0916H9E8
WH-UD12HE8
WH-ADC1216H6E5
WH-UD16HE5
WH-ADC1216G6E5¹
WH-UD16FE5
WH-ADC0916H9E8
WH-UD16HE8
WH-SDC07H3E5(-1)
WH-UD07HE5(-1)
WH-SDC09H3E5(-1)
WH-UD09HE5(-1)
WH-SDC09H3E8
WH-UD09HE8
WH-SDC12H6E5
WH-UD12HE5
WH-SDC12H9E8
WH-UD12HE8
WH-SDC16H6E5
WH-UD16HE5
WH-SDC16H9E8
WH-UD16HE8
WH-MDC07H3E5
WH-MDC06G3E5
(6kW)
WH-MDC09H3E5
WH-MDC09G3E5
WH-MDC12G6E5
WH-MDC16G6E5
WH-ADC1216H6E5
WH-UX09HE5
WH-ADC0916H9E8
WH-UX09HE8
WH-ADC1216H6E5
WH-UX12HE5
WH-ADC0916H9E8
WH-UX12HE8
WH-ADC0916H9E8
WH-UX16HE8
WH-SXC09H3E5
WH-UX09HE5
WH-SXC09H3E8
WH-UX09HE8
WH-SQC09H3E8
WH-UQ09HE8
WH-SXC12H6E5
WH-UX12HE5
WH-SXC12H9E8
WH-UX12HE8
WH-SQC12H9E8
WH-UQ12HE8
WH-SXC16H9E8
WH-UX16HE8
WH-SQC16H9E8
WH-UQ16HE8
WH-MXC09G3E5
WH-MXC09G3E8
WH-MXC12G6E5
WH-MXC12G9E8
WH-MXC16G9E8
WH-SHF09F3E5
WH-UH09FE5
WH-SHF09F3E8
WH-UH09FE8
WH-SHF12F6E5
WH-UH12FE5
WH-SHF12F9E8
WH-UH12FE8
WH-MHF09G3E5
WH-MHF12G6E5
41
NEW
TECHNOLOGY
AQUAREA ALL IN ONE H GENERATION HIGH PERFORMANCE
BI‑BLOC SINGLE PHASE / THREE PHASE. HEATING AND
COOLING. 1 ZONE HYDROKIT OR 2 ZONES BUILT-IN HYDROKIT
FREE
MAINTENANCE
STAINLESS TANK
Panasonic has developed a highly
efficient solution, easy to install.
· Space saving: 1.800 x 598 x 717 (H x W x D)
· Reduced installation costs
· Piping at the bottom of the All in One (easy to
install)
· Reduced installation time and minimised
installation errors
· Easy remote controller to set up
· Reduced installation spaces
· Electrical connections at the front
· Easier installation and maintenance
· New remote controller functions (cooling mode
activation possible by software. This activation
can only be done by service partner)
Aquarea All in One is the new generation of
Panasonic Heat Pumps for Heating, Cooling and
Domestic Hot Water (DHW). This new range
intelligently integrates the best Hydrokit technology
with a premium quality stainless steel tank, which
also comes with a 10 year warranty.
Technical focus
· NEW! Indoor Unit
· NEW! Touch Controller
WH-UD03HE5-1
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1
WH-UD12HE5
WH-UD16HE5
WH-UD09HE8
WH-UD12HE8
WH-UD16HE8
Single Phase (Power to indoor)
Three Phase (Power to indoor)
KIT‑ADC03HE5 KIT‑ADC05HE5 KIT‑ADC07HE5 KIT‑ADC09HE5 KIT‑ADC12HE5¹* KIT‑ADC16HE5¹* KIT‑ADC9HE8² KIT‑ADC12HE8² KIT‑ADC16HE8²
3,20
5,00
7,00
9,00
12,00
16,00
9,00
12,00
16,00
5,00
4,63
4,46
4,13
4,74
4,28
4,84
4,74
4,28
3,20
4,20
6,55
6,70
11,40
13,00
9,00
11,40
13,00
3,56
3,11
3,34
3,13
3,44
3,28
3,59
3,44
3,28
3,20
4,20
5,15
5,90
10,00
11,40
9,00
10,00
11,40
2,69
2,59
2,68
2,52
2,73
2,57
2,85
2,73
2,57
3,20
4,50
6,00
7,00
10,00
12,20
7,00
10,00
12,20
3,08
2,69
2,63
2,43
2,81
2,56
3,17
2,85
2,56
i/i/a i/i/a i/i/a i/i/a i/i/a i/i/a i/i/a i/i/a i/i/a
j/i j/i j/i j/i j/i j/i j/i j/i j/i
WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC1216H6E5 WH-ADC1216H6E5 WH-ADC0916H9E8 WH-ADC0916H9E8 WH-ADC0916H9E8
WH-ADC0309H3E5BWH-ADC0309H3E5BWH-ADC0309H3E5BWH-ADC0309H3E5B
—
—
—
—
—
28 / 28
28 / 28
28 / 28
28 / 28
33 / 33
33 / 33
33 / 33
33 / 33
33 / 33
1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717 1.800 x 598 x 717
mm / kg
/ 124
/ 124
/ 124
/ 124
/—
/—
/ 126
/ 126
/ 126
mm
R1¼
R1¼
R1¼
R1¼
R1¼
R1¼
R1¼
R1¼
R1¼
Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed
W
30 / 120
30 / 120
30 / 120
30 / 120
36 / 152
36 / 152
36 / 152
36 / 152
36 / 152
l/min
9,2
14,3
20,1
25,8
34,4
45,9
25,8
34,4
45,9
kW
3
3
3
3
6
6
9
9
9
A
15 / 15
15 / 15
30 / 15
30 / 15
30 / 30
30 / 30
16 / 16
16 / 16
16 / 16
mm²
3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5 3 x 2,5 / 3 x 1,5 3 x 2,5 / 3 x 1,5 3 x 4,0 / 3 x 4,0 3 x 4,0 / 3 x 4,0 5 x 1,5 / 5 x 1,5 5 x 1,5 / 5 x 1,5 5 x 1,5 / 5 x 1,5
L
185
185
185
185
185
185
185
185
185
°C
65
65
65
65
65
65
65
65
65
Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1 WH-UD12HE5 WH-UD16HE5 WH-UD09HE8 WH-UD12HE8 WH-UD16HE8
dB(A)
48 / 47
49 / 48
50 / 48
51 / 50
52 / 50
55 / 54
51 / 49
52 / 50
55 / 54
dB
64 / 65
65 / 66
68 / 66
69 / 68
67 / 68
70 / 72
68 / 67
69 / 68
72 / 72
622 x 824 x 298 622 x 824 x 298 795 x 900 x 320 795 x 900 x 320 1.340 x 900 x 320 1.340 x 900 x 320 1.340 x 900 x 320 1.340 x 900 x 320 1.340 x 900 x 320
mm / kg
/ 101
/ 107
/ 107
/ 107
/ 39
/ 39
/ 66
/ 66
/ 101
kg / TCO2 Eq.
1,20 / 2,506
1,20 / 2,506
1,45 / 3,028
1,45 / 3,028
2,55 / —
2,55 / —
2,55 / 5,324
2,55 / 5,324
2,55 / 5,324
1/4 (6,35) /
1/4 (6,35) /
1/4 (6,35) /
1/4 (6,35) /
3/8 (9,52) /
3/8 (9,52) /
3/8 (9,52) /
3/8 (9,52) /
3/8 (9,52) /
Inch (mm)
1/2 (12,7)
1/2 (12,7)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
m
3 ~ 15 / 5
3 ~ 15 / 5
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
m / g/m
10 / 20
10 / 20
10 / 30
10 / 30
10 / 50
10 / 50
10 / 50
10 / 50
10 / 50
°C
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
°C
25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20
Kit
Heating capacity at +7°C (heating water at 35°C)
kW
COP at +7°C (heating water at 35°C)
W/W
Heating capacity at +2°C (heating water at 35°C)
kW
COP at +2°C (heating water at 35°C)
W/W
Heating capacity at -7°C (heating water at 35°C)
kW
COP at -7°C (heating water at 35°C)
W/W
Cooling capacity at 35°C (cooling water at 7/12°C)
kW
EER at 35°C (cooling water at 7/12°C)
W/W
Energy Efficiency Class at 35°C / at 55°C / at 55°C for DHW
System label 35°C / 55°C³
Indoor unit 1 zone
Indoor unit 2 zones
Sound pressure
Heating / Cooling
dB(A)
Dimensions* / Net Weight* H x W x D
Water pipe connector
Number of speeds
Input power (Min / Max)*
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Recommended Fuse
Recommended cable size, supply 1 & 2
Water volume
Maximum water temperature
Material inside tank
Outdoor Unit
Sound pressure
Heating / Cooling
Sound power level
Heating / Cooling
A class Pump
Dimensions / Weight
HxWxD
Refrigerant (R410A)
Pipe diameter
Liquid / Gas
Pipe length range / Elevation difference (in/out)
Pipe length for additional gas / Additional gas amount
Operation range
Outdoor ambient
Water outlet
Heating / Cooling
Accessories
PAW-ADC-PREKIT-1
PAW-ADC-CV150
CZ-NS4P
Accessories
Aquarea Smart Cloud, H Generation Internet control through Wifi or wired LAN
CZ-TAW1
PAW-A2W-RTWIRED Room thermostat
Pre installation kit for piping
Decorative magnetic side cover
Additional functions PCB
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
Insulated tested under EN12897. 1) Available in August 2017. 2) Available in March 2017. 3) System label with controller. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
INTERNET CONTROL: Optional.
42
A
DHW 55°C
A CLASS
5,00
AUTO SPEED
HIGH PERFORMANCE
WATER PUMP
-20°C
COP
DHW
HEATING MODE
STOP
WATER FILTER
STOP VALVE
BMS
FLOW SENSOR
BOILER CONNECTION
ADVANCED CONTROL
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
10
YEARS
VESSEL TANK
WARRANTY
NEW / AQUAREA
NEW
TECHNOLOGY
AQUAREA ALL IN ONE H GENERATION T‑CAP
BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING
FREE
MAINTENANCE
STAINLESS TANK
Benefits of the T‑CAP All in One unit!
· Works at temperatures as low as -28°C
· Constant capacity up to -20°C
· Space saving: 1.800 x 598 x 717 (H x W x D)
· Reduced installation costs
· P iping at the bottom of the All in One (easy to install)
· Reduced installation time and minimised
installation errors
· Easy remote controller to set up
· Reduced installation spaces
· Electrical connections at the front
· Easier installation and maintenance
· 1 phase and 3 phase
· New remote controller functions (cooling mode
activation possible by software. This activation
can only be done by service partner)
Aquarea T‑CAP can work in extreme outdoor
conditions as low as -28°C and warranty the capacity
without back up heating down to -20°C. Ready to
work at extreme outdoor conditions the H Generation
T‑CAP can produce water up to 60°C, expanding its
possibilities for retrofit application. On top of All in
One Aquarea unique advantages, the quickest
installation in the market and easy maintenance
including the outstanding inox tank maintenance free.
Technical focus
· NEW! Indoor Unit
· NEW! Touch Controller
Single Phase (Power to indoor)
KIT‑AXC9HE5¹
KIT‑AXC12HE5¹
9,00
12,00
4,84
4,74
9,00
12,00
3,59
3,44
9,00
12,00
2,85
2,72
7,00
10,00
3,17
2,81
i/i/a
i/i/a
j/i
j/i
WH-ADC1216H6E5
WH-ADC1216H6E5
33 / 33
33 / 33
1.800 x 598 x 717 / 137
1.800 x 598 x 717 / 137
R1¼
R1¼
Variable Speed
Variable Speed
36 / 152
36 / 152
25,8
34,4
6
6
30 / 30
30 / 30
3 x 4,0 / 3 x 4,0
3 x 4,0 / 3 x 4,0
185
185
65
65
Stainless steel
Stainless steel
WH-UX09HE5
WH-UX12HE5
51 / 49
52 / 50
Kit
Heating capacity at +7°C (heating water at 35°C)
kW
COP at +7°C (heating water at 35°C)
W/W
Heating capacity at +2°C (heating water at 35°C)
kW
COP at +2°C (heating water at 35°C)
W/W
Heating capacity at -7°C (heating water at 35°C)
kW
COP at -7°C (heating water at 35°C)
W/W
Cooling capacity at 35°C (cooling water at 7/12°C)
kW
EER at 35°C (cooling water at 7/12°C)
W/W
Energy Efficiency Class at 35°C / at 55°C / at 55°C for DHW
System label 35°C / 55°C³
Indoor unit
Sound pressure
Heating / Cooling
dB(A)
Dimensions* / Net Weight* H x W x D
mm / kg
Water pipe connector
mm
Number of speeds
A class pump
Input power (Min / Max)* W
Heating water flow (∆T=5 K. 35°C)
L/min
Capacity of integrated electric heater
kW
Recommended fuse
A
Recommended cable size, supply 1 & 2
mm²
Water volume
L
Maximum water temperature
°C
Material inside tank
Outdoor Unit
Sound pressure
Heating / Cooling
dB(A)
Sound power level
Heating / Cooling
dB
Dimensions / Weight
HxWxD
mm / kg
Refrigerant (R410A)
kg / TCO2 Eq.
Pipe diameter
Liquid / Gas
Inch (mm)
Pipe length range / Elevation difference (in/out)
m
Pipe length for additional gas / Additional gas amount m / g/m
Operation range
Outdoor ambient
°C
Water outlet
Heating / Cooling
°C
Accessories
PAW-ADC-PREKIT-1
PAW-ADC-CV150
CZ-NS4P
1.340 x 900 x 320 / 101
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 ~ 60 / 5 ~ 20
KIT‑AXC9HE8²
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i/i/a
j/i
WH-ADC0916H9E8
33 / 33
1.800 x 598 x 717 / 126
R1¼
Variable Speed
36 / 152
25,8
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UX09HE8
51 / 49
68 / 67
1.340 x 900 x 320 / 108
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 ~ 60 / 5 ~ 20
1.340 x 900 x 320 / 101
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 ~ 60 / 5 ~ 20
WH-UX09HE5
WH-UX12HE5
WH-UX09HE8
WH-UX12HE8
WH-UX16HE8
Three Phase (Power to indoor)
KIT‑AXC12HE8²
12,00
4,74
12,00
3,44
12,00
2,72
10,00
2,81
i/i/a
j/i
WH-ADC0916H9E8
33 / 33
1.800 x 598 x 717 / 126
R1¼
Variable Speed
36 / 152
34,4
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UX12HE8
52 / 50
69 / 68
1.340 x 900 x 320 / 108
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 ~ 60 / 5 ~ 20
KIT‑AXC16HE8²
16,00
4,28
16,00
3,10
16,00
2,49
12,20
2,57
i/i/a
j/i
WH-ADC0916H9E8
33 / 33
1.800 x 598 x 717 / 126
R1¼
Variable Speed
36 / 152
45,9
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UX16HE8
55 / 54
72 / 71
1.340 x 900 x 320 / 118
2,90 / 6,055
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 ~ 60 / 5 ~ 20
Accessories
Aquarea Smart Cloud, H Generation Internet control through Wifi or wired LAN
CZ-TAW1
PAW-A2W-RTWIRED Room thermostat
Pre installation kit for piping
Decorative magnetic side cover
Additional functions PCB
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
Insulated tested under EN12897. 1) Available in July 2017. 2) Available in March 2017. 3) System label with controller. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
A
DHW 55°C
A CLASS
-20°C
WATER PUMP
CONSTANT HEATING
AUTO SPEED
T-CAP
WATER AT
-28°C
60°C
FLOW TEMPERATURE
DHW
HEATING MODE
STOP
WATER FILTER
STOP VALVE
BMS
FLOW SENSOR
BOILER CONNECTION ADVANCED CONTROL
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
10
YEARS
VESSEL TANK
WARRANTY
INTERNET CONTROL: Optional.
43
AQUAREA ALL IN ONE HIGH PERFORMANCE
BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING
Panasonic has developed a highly
efficient solution, easy to install.
installation errors
· Easy remote controller to set up
· Electrical connections at the front
· Reduced installation spaces
· All piping connections at bottom of the indoor
unit
· Easier installation and maintenance
· New remote controller functions (cooling mode
activation possible by software. This activation
can only be done by service partner)
Panasonic combines the finest product design with
performance to achieve a market-leading COP.
Technical focus
· Space saving: 1.800 x 598 x 717 (H x W x D)
· Reduced installation costs
· Piping at the bottom of the All in One (easy to
install)
· Reduced installation time and minimised
WH-UD12FE5
WH-UD16FE5
WH-UD09FE8
Kit
Heating capacity at +7°C (heating water at 35°C)
kW
COP at +7°C (heating water at 35°C)
W/W
Heating capacity at +2°C (heating water at 35°C)
kW
COP at +2°C (heating water at 35°C)
W/W
Heating capacity at -7°C (heating water at 35°C)
kW
COP at -7°C (heating water at 35°C)
W/W
Cooling capacity at 35°C (cooling water at 7/12°C)
kW
EER at 35°C (cooling water at 7/12°C)
W/W
Energy Efficiency Class at 35°C / at 55°C / at 55°C for DHW
Indoor Unit
Sound pressure
Heating / Cooling
dB(A)
Dimensions / Net Weight H x W x D
mm / kg
Water pipe connector
mm
Number of speeds
A class Pump
Input power (Min / Max)
W
Heating water flow (∆T=5 K. 35°C)
l/min
Capacity of integrated electric heater
kW
Recommended Fuse
A
Recommended cable size, supply 1 & 2
mm²
Water volume
L
Maximum water temperature
°C
Material inside tank
Outdoor Unit
Sound pressure
Heating / Cooling
dB(A)
Dimensions / Weight
HxWxD
mm / kg
Refrigerant (R410A)
kg / TCO2 Eq.
Pipe diameter
Liquid / Gas
Inch (mm)
Pipe length range / Elevation difference (in/out)
m
Pipe length for additional gas / Additional gas amount m / g/m
Operation range
Outdoor ambient
°C
Water outlet
Heating / Cooling
°C
Accessories
PAW-ADC-PREKIT
PAW-ADC-CV150
PAW-BTANK50L
PA-AW-WIFI-1TE
Single Phase (Power to indoor)
KIT‑ADC12GE5
KIT‑ADC16GE5
12,00
16,00
4,74
4,28
11,40
13,00
3,44
3,28
10,00
11,40
2,73
2,68
10,00
12,20
2,81
2,56
i/i/a
i/i/a
WH-ADC1216G6E5
WH-ADC1216G6E5
33 / 33
33 / 33
1.800 x 598 x 717 / —
1.800 x 598 x 717 / —
R1¼
R1¼
7
7
36 / 152
36 / 152
34,4
45,9
6
6
30 / 30
30 / 30
3 x 4,0 / 3 x 4,0
3 x 4,0 / 3 x 4,0
185
185
65
65
Stainless steel
Stainless steel
WH-UD12FE5
WH-UD16FE5
52 / 50
55 / 54
1.340 x 900 x 320 / 101
1.340 x 900 x 320 / 101
2,55 / 5,324
2,55 / 5,324
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
3 ~ 30 / 20
10 / 50
10 / 50
-20 ~ +35
-20 ~ +35
25 ~ 55 / 5 ~ 20
25 ~ 55 / 5 ~ 20
KIT‑ADC9GE8
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i/i/a
WH-ADC0916G9E8
33 / 33
1.800 x 598 x 717 / 139
R1¼
7
36 / 152
25,8
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UD09FE8
51 / 49
1.340 x 900 x 320 / 108
2,55 / 5,324
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-20 ~ +35
25 ~ 55 / 5 ~ 20
WH-UD12FE8
WH-UD16FE8
Three Phase (Power to indoor)
KIT‑ADC12GE8
12,00
4,74
11,40
3,44
10,00
2,73
10,00
2,85
i/i/a
WH-ADC0916G9E8
33 / 33
1.800 x 598 x 717 / 139
R1¼
7
36 / 152
34,4
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UD12FE8
52 / 50
1.340 x 900 x 320 / 108
2,55 / 5,324
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-20 ~ +35
25 ~ 55 / 5 ~ 20
KIT‑ADC16GE8
16,00
4,28
13,00
3,28
11,40
2,57
12,20
2,56
i/i/a
WH-ADC0916G9E8
33 / 33
1.800 x 598 x 717 / 139
R1¼
7
36 / 152
45,9
9
16 / 16
5 x 1,5 / 5 x 1,5
185
65
Stainless steel
WH-UD16FE8
55 / 54
1.340 x 900 x 320 / 108
2,55 / 5,324
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-20 ~ +35
25 ~ 55 / 5 ~ 20
Accessories
Bivalent control
PAW-A2W-BIV
Filter
PAW-FILTER
PAW-A2W-RTWIRED Room thermostat
Pre installation kit for piping
Decorative magnetic side cover
Buffer tank 50L
Wifi interface
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
1) Insulated tested under EN12897.
A++
ErP 55°C
A++
ErP 35°C
INTERNET CONTROL: Optional.
44
A
DHW 55°C
A CLASS
5,00
7 SPEEDS
HIGH PERFORMANCE
WATER PUMP
-20°C
COP
DHW
HEATING MODE
BMS
BOILER CONNECTION
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
10
YEARS
VESSEL TANK
WARRANTY
NEW / AQUAREA
AQUAREA ALL IN ONE T‑CAP
BI‑BLOC SINGLE PHASE.
HEATING AND COOLING
All the benefits of the T‑CAP All in One
unit!
Panasonic has developed a highly efficient
solution, easy to install. Ideal for installation in
new homes, Aquarea All in One is also particularly
suited for retrofit projects, saving installation time
and space.
Technical focus
· Space saving: 1.800 x 598 x 717 (H x W x D)
· Reduced installation costs
· Piping at the bottom of the All in One (easy to
install)
· Reduced installation time and minimised
installation errors
· Easy remote controller to set up
· Electrical connections at the front
· Reduced installation spaces
· All piping connections at bottom of the indoor
unit
· Easier installation and maintenance
· New remote controller functions
WH-UX09FE5
WH-UX12FE5
Single Phase (Power to indoor)
Kit
Heating capacity at +7°C (heating water at 35°C)
kW
COP at +7°C (heating water at 35°C)
W/W
Heating capacity at +2°C (heating water at 35°C)
kW
COP at +2°C (heating water at 35°C)
W/W
Heating capacity at -7°C (heating water at 35°C)
kW
COP at -7°C (heating water at 35°C)
W/W
Cooling capacity at 35°C (cooling water at 7/12°C)
kW
EER at 35°C (cooling water at 7/12°C)
W/W
Energy Efficiency Class at 35°C / at 55°C / at 55°C for DHW
Indoor Unit
Sound pressure
Heating / Cooling
dB(A)
Dimensions / Net Weight H x W x D
mm / kg
Water pipe connector
Number of speeds
A class Pump
Input power (Min / Max)
W
Heating water flow (∆T=5 K. 35°C)
l/min
Capacity of integrated electric heater
kW
Recommended Fuse
A
Recommended cable size, supply 1 & 2
mm²
Water volume
L
Maximum water temperature
°C
Material inside tank
Outdoor Unit
Sound pressure
Heating / Cooling
dB(A)
Dimensions / Weight
HxWxD
mm / kg
Refrigerant (R410A)
kg / TCO2 Eq.
Pipe diameter
Liquid / Gas
Inch (mm)
Pipe length range / Elevation difference (in/out)
m
Pipe length for additional gas / Additional gas amount m / g/m
Operation range
Outdoor ambient
°C
Water outlet
Heating / Cooling
°C
Accessories
PAW-ADC-PREKIT
PAW-ADC-CV150
PAW-BTANK50L
PA-AW-WIFI-1TE
KIT‑AXC9GE5
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i/i/a
WH-ADC1216G6E5
33 / 33
1.800 x 598 x 717 / 137
R1¼
7
36 / 152
25,8
6
30 / 30
3 x 4,0 / 3 x 4,0
185
65
Stainless steel
WH-UX09FE5
51 / 49
1.340 x 900 x 320 / 101
2,85 / —
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-20 ~ +35
25 ~ 55 / 5 ~ 20
KIT‑AXC12GE5
12,00
4,74
12,00
3,44
12,00
2,72
10,00
2,81
i/i/a
WH-ADC1216G6E5
33 / 33
1.800 x 598 x 717 / 137
R1¼
7
36 / 152
34,4
6
30 / 30
3 x 4,0 / 3 x 4,0
185
65
Stainless steel
WH-UX12FE5
52 / 50
1.340 x 900 x 320 / 101
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-20 ~ +35
25 ~ 55 / 5 ~ 20
Accessories
Bivalent control
PAW-A2W-BIV
Filter
PAW-FILTER
PAW-A2W-RTWIRED Room thermostat
Pre installation kit for piping
Decorative magnetic side cover
Buffer tank 50L
Wifi interface
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
1) Insulated tested under EN12897.
A++
ErP 55°C
A++
ErP 35°C
A
DHW 55°C
A CLASS
-15°C
WATER PUMP
CONSTANT HEATING
7 SPEEDS
T-CAP
-20°C
DHW
HEATING MODE
BMS
BOILER CONNECTION
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
10
YEARS
VESSEL TANK
WARRANTY
INTERNET CONTROL: Optional.
45
NEW
TECHNOLOGY
AQUAREA H GENERATION HIGH PERFORMANCE
BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING - SDC
The new H Generation are specially
designed for low energy homes and
achieve an impressive COP of 5 (on the
3,2kW).
Thanks to the system’s high degree of technology
and advanced control, it is able to maintain a high
capacity and efficiency even at -7°C and -15°C.
The Aquarea’s software is optimised to the
requirements of low consumption homes in order
to maximise energy efficiency. Whatever the
weather, Aquarea can work even at -20°C. The
compact design of the outdoor unit makes
installation very easy.
Kit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7/12°C)
EER at 35°C (cooling water at 7/12°C)
Energy Efficiency Class at 35°C / 55°C
System label 35°C / 55°C²
Indoor Unit³
Sound pressure
Heating / Cooling
Dimensions / Weight
HxWxD
Water pipe connector
Number of speeds
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Recommended fuse
Recommended cable size, supply 1 & 2
Outdoor Unit³
Sound pressure
Heating / Cooling
A class pump
Dimensions / Weight
HxWxD
Refrigerant (R410A)
Pipe diameter
Liquid / Gas
Pipe length range / Elevation difference (in/out)
Pipe length for additional gas / Additional gas amount
Operation range
Outdoor ambient
Water outlet
Heating / Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
Technical focus
· NEW! Touch Controller
· NEW! Indoor Unit
· Super efficient: COP of 5 in the 3,2kW!
· Very high energy savings A+++ (*)
· Simple installation & maintenance
· Special software for low consumption homes
with minimum output temperature: 20°C
· Works at temperatures as low as -20°C
· Automatic Air purge valve
· Display of the compressor frequency
WH-UD03HE5 (-1)
WH-UD05HE5 (-1)
Single Phase Heating and Cooling
KIT‑WC03H3E5 KIT‑WC05H3E5 KIT‑WC07H3E5 KIT‑WC09H3E5 KIT‑WC012H6E5¹ KIT‑WC016H6E5¹
kW
3,20
5,00
7,00
9,00
12,00
16,00
W/W
5,00
4,63
4,46
4,13
4,74
4,28
kW
3,20
4,20
6,55
6,70
11,40
13,00
W/W
3,56
3,11
3,34
3,13
3,44
3,28
kW
3,20
4,20
5,15
5,90
10,00
11,40
W/W
2,69
2,59
2,68
2,52
2,73
2,57
kW
3,20
4,50
6,00
7,00
10,00
12,20
W/W
3,08
2,69
2,63
2,43
2,81
2,56
i* / i i* / i i* / i i* / i i* / i i* / i
j/i j/i j/i j/i j/i j/i
WH-SDC03H3E5 (-1) WH-SDC05H3E5 (-1) WH-SDC07H3E5 (-1) WH-SDC09H3E5 (-1) WH-SDC12H6E5 WH-SDC16H6E5
dB(A)
28 / 28
28 / 28
30 / 30
30 / 30
33 / 33
33 / 33
892 x 500 x 340 / 892 x 500 x 340 / 892 x 500 x 340 / 892 x 500 x 340 / 892 x 500 x 340 / 892 x 500 x 340 /
mm / kg
44
44
44
44
44
45
mm
R1¼
R1¼
R1¼
R1¼
R1¼
R1¼
Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed
W
30 / 100
33 / 106
34 / 114
40 / 120
34 / 110
30 / 105
L/min
9,2
14,3
20,1
25,8
34,4
45,9
kW
3
3
3
3
6
6
A
15 / 30
15 / 30
15 / 30
15 / 30
30 / 30
30 / 30
mm²
3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5 3 x 4,0 or 6,0 / 3 x 4,0 3 x 4,0 or 6,0 / 3 x 4,0
WH-UD03HE5 (-1) WH-UD05HE5 (-1) WH-UD07HE5 (-1) WH-UD09HE5 (-1) WH-UD12HE5 WH-UD16HE5
dB(A)
47 / 47
48 / 48
50 / 48
51 / 50
52 / 50
55 / 54
622 x 824 x 298 / 622 x 824 x 298 / 795 x 900 x 320 / 795 x 900 x 320 / 1.340 x 900 x 320 1.340 x 900 x 320
mm / kg
39
39
66
66
/ 101
/ 101
1,20 / —
1,20 / —
1,45 / —
1,45 / —
2,55 / —
2,55 / —
kg / TCO2 Eq.
1/4 (6,35) / 1/2 1/4 (6,35) / 1/2 1/4 (6,35) / 5/8 1/4 (6,35) / 5/8 3/8 (9,52) / 5/8 3/8 (9,52) / 5/8
Inch (mm)
(12,7)
(12,7)
(15,88)
(15,88)
(15,88)
(15,88)
m
3 ~ 15 / 5
3 ~ 15 / 5
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
m / g/m
10 / 20
10 / 20
10 / 30
10 / 30
10 / 50
10 / 50
°C
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
°C
20 ~ 55 / 5 ~ 20 20 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20
Accessories
CZ-NV1
CZ-NS4P
PAW-BTANK50L
CZ-TAW1
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
WH-UD07HE5 (-1)
WH-UD09HE5 (-1)
WH-UD12HE5
WH-UD16HE5
WH-UD09HE8
WH-UD12HE8
WH-UD16HE8
Three Phase (Power to indoor)
KIT‑WC09H3E8¹ KIT‑WC12H9E8¹ KIT‑WC16H9E8¹
9,00
12,00
16,00
4,84
4,74
4,28
9,00
11,40
13,00
3,59
3,44
3,28
9,00
10,00
11,40
2,85
2,73
2,57
7,00
10,00
12,20
3,17
2,81
2,56
i
i
i
i
i
i
WH-SDC09H3E8 WH-SDC12H9E8 WH-SDC16H9E8
33 / 33
33 / 33
33 / 33
892 x 500 x 340 / 892 x 500 x 340 / 892 x 500 x 340 /
44
45
45
R1¼
R1¼
R1¼
Variable Speed Variable Speed Variable Speed
32 / 102
34 / 110
30 / 105
25,8
34,4
45,9
3
9
9
15 / 30
15 / 30
15 / 30
3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5 3 x 1,5 / 3 x 1,5
WH-UD09HE8 WH-UD12HE8 WH-UD16HE8
51 / 49
52 / 50
55 / 54
1.340 x 900 x 320 1.340 x 900 x 320 1.340 x 900 x 320
/ 107
/ 107
/ 107
2,55 / —
2,55 / —
2,55 / —
3/8 (9,52) / 5/8 3/8 (9,52) / 5/8 3/8 (9,52) / 5/8
(15,88)
(15,88)
(15,88)
3 ~ 30 / 20
3 ~ 30 / 20
3 ~ 30 / 20
10 / 50
10 / 50
10 / 50
-20 ~ +35
-20 ~ +35
-20 ~ +35
25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20 25 ~ 55 / 5 ~ 20
3 way valve Kit for inside of hydrokit
Additional functions PCB
Buffer tank 50L
Aquarea Smart Cloud, H Generation Internet control through Wifi or wired LAN
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Performance in agreement with EN14511.
Remark to energy efficiency class: These indications are based on the official ErP regulations (EU regulations N° 811/2013, EN 14511 and EN 14825) for heat pumps, which is officially binding from September 2015. Efficiency classes marked with * would meet the new
regulations from September 2019 to a classification as A+++. 1) Available in May 2017. 2) System label with controller. 3) New references from March 2017: WH-SDC_ _H3E5-1 and WH-UD_ _HE5-1. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
A CLASS
5,00
AUTO SPEED
HIGH PERFORMANCE
WATER PUMP
INTERNET CONTROL: Optional.
46
Stainless steel
-20°C
COP
Enamelled
DHW
HEATING MODE
STOP
WATER FILTER
STOP VALVE
BMS
FLOW SENSOR
BOILER CONNECTION
SOLAR KIT
ADVANCED CONTROL
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
NEW / AQUAREA
NEW
TECHNOLOGY
AQUAREA H GENERATION T‑CAP
BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING - SXC
The best for extreme outdoor conditions.
Constant capacity at -20°C.
Technical focus
· NEW! Touch Controller
· NEW! Indoor Unit
· Very high energy savings A++
· Simple installation & maintenance
· Constant capacity up to -20°C
· Water temperature up to 60°C
· Special software for low consumption homes
with minimum output temperature: 20°C
· Works at temperatures as low as -28°C
· Automatic Air purge valve
· Display of the compressor frequency
Aquarea T‑CAP can work in extreme outdoor
conditions as low as -28°C and warranty the
capacity without back up heating down to 20°C.
Ready to work at extreme outdoor conditions the
H Generation T‑CAP can produce water up to 60°C,
expanding its possibilities for retrofit application.
H Generation is the quickest to install and easiest
maintenance.
WH-UX09HE5
WH-UX12HE5
WH-UX09HE8
Kit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Indoor Unit
Sound pressure
Heating / Cooling
Dimensions / Weight*
HxWxD
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Recommended Fuse
Recommended cable size, supply 1 & 2
Outdoor Unit
Sound pressure
Heating / Cooling
Dimensions / Weight
HxWxD
Refrigerant (R410A)
Pipe diameter
Liquid / Gas
Pipe length range / Elevation difference (in/out)
Pipe length for additional gas / Additional gas amount
Operation range
Outdoor ambient
Water outlet
Heating / Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
mm / kg
W
l/min
kW
A
mm²
dB(A)
mm / kg
kg / TCO2 Eq.
Inch (mm)
m
m / g/m
°C
°C
Single Phase (Power to indoor)
KIT‑WXC09H3E5¹
KIT‑WXC12H6E5¹
9,00
12,00
4,84
4,74
9,00
12,00
3,59
3,44
9,00
12,00
2,85
2,72
7,00
10,00
3,17
2,81
i
i
i
i
WH-SXC09H3E5
WH-SXC12H6E5
33 / 33
33 / 33
892 x 500 x 340 / 43
892 x 500 x 340 / 43
R1¼
R1¼
Variable Speed
Variable Speed
32 / 102
34 / 110
25,8
34,4
3
6
30 / 30
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
3 x 4,0 or 6,0 / 3 x 4,0
WH-UX09HE5
WH-UX12HE5
51 / 49
52 / 50
1.340 x 900 x 320 / 101
1.340 x 900 x 320 / 101
2,85 / 5,951
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
3 ~ 30 / 20
10 / 50
10 / 50
-28 ~ +35
-28 ~ +35
25 - 60 / 5 - 20
25 - 60 / 5 - 20
KIT‑WXC09H3E8
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i
i
WH-SXC09H3E8
33 / 33
892 x 500 x 340 / 43
R1¼
Variable Speed
32 / 102
25,8
3
16 / 16
5 x 1,5 / 3 x 1,5
WH-UX09HE8
51 / 49
1.340 x 900 x 320 / 108
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
Accessories
CZ-NV1
CZ-NS4P
PAW-BTANK50L
CZ-TAW1
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
WH-UX12HE8
WH-UX16HE8
Three Phase (Power to indoor)
KIT‑WXC12H9E8
12,00
4,74
12,00
3,44
12,00
2,72
10,00
2,81
i
i
WH-SXC12H9E8
33 / 33
892 x 500 x 340 / 44
R1¼
Variable Speed
34 / 110
34,4
9
16 / 16
5 x 1,5 / 5 x 1,5
WH-UX12HE8
52 / 50
1.340 x 900 x 320 / 108
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
KIT‑WXC16H9E8
16,00
4,28
16,00
3,10
16,00
2,49
12,20
2,57
i
i
WH-SXC16H9E8
33 / 33
892 x 500 x 340 / 45
R1¼
Variable Speed
30 / 105
45,9
9
16 / 16
5 x 1,5 / 5 x 1,5
WH-UX16HE8
55 / 54
1.340 x 900 x 320 / 118
2,90 / 6,055
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
3 way valve Kit for inside of hydrokit
Additional functions PCB
Buffer tank 50L
Aquarea Smart Cloud, H Generation Internet control through Wifi or wired LAN
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
1) Available in April 2017. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
A CLASS
-20°C
WATER PUMP
CONSTANT HEATING
AUTO SPEED
T-CAP
-28°C
DHW
HEATING MODE
STOP
WATER FILTER
STOP VALVE
BMS
FLOW SENSOR
BOILER CONNECTION
SOLAR KIT
ADVANCED CONTROL
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
INTERNET CONTROL: Optional.
47
NEW
TECHNOLOGY
AQUAREA H GENERATION T‑CAP
BI‑BLOC THREE PHASE. SUPER QUIET OUTDOOR UNIT.
HEATING AND COOLING - SQC
The best for extreme outdoor conditions.
Constant capacity at -20°C.
Aquarea T‑CAP can work in extreme outdoor
conditions as low as -28°C and warranty the
capacity without back up heating down to 20°C.
Ready to work at extreme outdoor conditions the
H Generation T‑CAP can produce water up to 60°C,
expanding its possibilities for retrofit application.
H Generation is the quickest to install and easiest
maintenance.
Kit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Indoor Unit
Sound pressure
Heating / Cooling
Dimensions / Weight*
HxWxD
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Recommended Fuse
Recommended cable size, supply 1 & 2
Outdoor Unit
Sound pressure
Heating / Cooling
Dimensions / Weight
HxWxD
Refrigerant (R410A)
Pipe diameter
Liquid / Gas
Pipe length range / Elevation difference (in/out)
Pipe length for additional gas / Additional gas amount
Operation range
Outdoor ambient
Water outlet
Heating / Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
Technical focus
· NEW! Touch Controller
· NEW! Indoor Unit
· Very high energy savings A++
· Noise reduction of 7dB is based on power level
when heating mode
· With Quite mode we can reach 10 ~ 12dB(A)
· Simple installation & maintenance
· Constant capacity up to -20°C
· Water temperature up to 60°C
· Special software for low consumption homes
with minimum output temperature: 20°C
· Works at temperatures as low as -28°C
· Automatic Air purge valve
· Display of the compressor frequency
dB(A)
mm / kg
W
l/min
kW
A
mm²
dB(A)
mm / kg
kg / TCO2 Eq.
Inch (mm)
m
m / g/m
°C
°C
SUPER QUIET
OUTDOOR UNIT
WH-UQ09HE8
WH-UQ12HE8
WH-UQ16HE8
Three Phase. New Super Quiet outdoor unit
KIT‑WQC12H9E8
12,00
4,74
12,00
3,44
10,00
2,73
10,00
2,81
i
i
WH-SQC12H9E8
33 / 33
892 x 500 x 340 / 44
R1¼
Variable Speed
34 / 110
34,4
9
15 / 30
3 x 1,5 / 3 x 1,5
WH-UQ12HE8
48 / 49
1.410 x 1.283 x 320 / 151
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
KIT‑WQC09H3E8
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i
i
WH-SQC09H3E8
33 / 33
892 x 500 x 340 / 43
R1¼
Variable Speed
32 / 102
25,8
3
15 / 30
3 x 1,5 / 3 x 1,5
WH-UQ09HE8
47 / 48
1.410 x 1.283 x 320 / 151
2,85 / 5,951
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
kW
W/W
kW
W/W
kW
W/W
kW
W/W
NEW
Accessories
CZ-NV1
CZ-NS4P
PAW-BTANK50L
CZ-TAW1
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
KIT‑WQC16H9E8
16,00
4,28
16,00
3,10
11,40
2,68
12,20
2,57
i
i
WH-SQC16H9E8
33 / 33
892 x 500 x 340 / 45
R1¼
Variable Speed
30 / 105
45,9
9
15 / 30
3 x 1,5 / 3 x 1,5
WH-UQ16HE8
51 / 53
1.410 x 1.283 x 320 / 161
2,99 / 6,243
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
10 / 50
-28 ~ +35
25 - 60 / 5 - 20
3 way valve Kit for inside of hydrokit
Additional functions PCB
Buffer tank 50L
Aquarea Smart Cloud, H Generation Internet control through Wifi or wired LAN
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
1) Available in April 2017. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
INTERNET CONTROL: Optional.
48
A CLASS
-20°C
WATER PUMP
CONSTANT HEATING
AUTO SPEED
T-CAP
-28°C
DHW
HEATING MODE
STOP
WATER FILTER
STOP VALVE
BMS
FLOW SENSOR
BOILER CONNECTION
SOLAR KIT
ADVANCED CONTROL
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
NEW / AQUAREA
AQUAREA HT
BI‑BLOC SINGLE PHASE / THREE PHASE.
HEATING ONLY - SHF
Aquarea HT is able to deliver water
heated to 65°C with the Heat Pump
alone.
Technical focus
· New remote controller functions
· Efficient control of room temperature based on
the outdoor temperature, indoor temperature
using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 12kW, Single and Three Phase
· Maximum hydraulic module output temperature:
65°C
· Works at temperatures as low as -20°C
· Maximum 20m rise between the outdoor unit and
the hydraulic module
For a house with high temperature radiators (for
example, cast iron radiators), the Aquarea High
Temperature Solution is the most suited as it
provides output water temperatures of 65°C even
at -20°C.
WH-UH09FE5
WH-UH12FE5
Kit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Heating capacity at +7°C (heating water at 65°C)
COP at +7°C (heating water at 65°C)
Heating capacity at +2°C (heating water at 65°C)
COP at +2°C (heating water at 65°C)
Heating capacity at -7°C (heating water at 65°C)
COP at -7°C (heating water at 65°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Indoor Unit
Sound pressure
Dimensions / Weight
HxWxD
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Recommended Fuse
Recommended cable size, supply 1 & 2
Outdoor Unit
Sound pressure
Dimensions / Weight
HxWxD
Refrigerant (R407C)
Pipe diameter
Liquid / Gas
Pipe length range / Elevation difference (in/out)
Pipe length for additional gas / Additional gas amount
Operation range
Outdoor ambient
Water outlet
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
PAW-3WYVLV-SI
Single Phase (Power to indoor)
KIT‑WHF09F3E5
KIT‑WHF12F6E5
9,00
12,00
4,64
4,46
9,00
12,00
3,45
3,26
9,00
12,00
2,74
2,52
9,00
12,00
2,27
2,22
9,00
10,30
1,89
1,84
8,90
9,60
1,63
1,62
i
i
i
i
WH-SHF09F3E5
WH-SHF12F6E5
33
33
892 x 502 x 353 / 46
892 x 502 x 353 / 47
R1¼
R1¼
7
7
38 / 100
40 / 106
25,8
34,4
3
6
30 / 30
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
3 x 4,0 or 6,0 / 3 x 4,0
WH-UH09FE5
WH-UH12FE5
51
52
1.340 x 900 x 320 / 104
1.340 x 900 x 320 / 104
2,90 / 5,145
2,90 / 5,145
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
3 ~ 30 / 20
10 / 70
10 / 70
-20 ~ +35
-20 ~ +35
25 ~ 65
25 ~ 65
kW
W/W
kW
W/W
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
mm / kg
W
l/min
kW
A
mm²
dB(A)
mm / kg
kg / TCO2 Eq.
Inch (mm)
m
m / g/m
°C
°C
Accessories
PAW-BTANK50L
PA-AW-WIFI-1TE
PAW-A2W-BIV
PAW-FILTER
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
3 way valve
WH-UH09FE8
WH-UH12FE8
Three Phase (Power to indoor)
KIT‑WHF09F3E8
KIT‑WHF12F9E8
9,00
12,00
4,64
4,46
9,00
12,00
3,45
3,26
9,00
12,00
2,74
2,52
9,00
12,00
2,29
2,22
9,00
10,30
1,89
1,84
8,90
9,60
1,63
1,62
i
i
i
i
WH-SHF09F3E8
WH-SHF12F9E8
33
33
892 x 502 x 353 / 47
892 x 502 x 353 / 48
R1¼
R1¼
7
7
38 / 100
40 / 106
25,8
34,4
3
9
30 / 16
30 / 16
5 x 1,5 / 3 x 1,5
5 x 1,5 / 5 x 1,5
WH-UH09FE8
WH-UH12FE8
51
52
1.340 x 900 x 320 / 110
1.340 x 900 x 320 / 110
2,90 / 5,145
2,90 / 5,145
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3 ~ 30 / 20
3 ~ 30 / 20
10 / 70
10 / 70
-20 ~ +35
-20 ~ +35
25 ~ 65
25 ~ 65
Buffer tank 50L
Wifi interface
Bivalent control
Filter
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
A++
ErP 55°C
A++
ErP 35°C
A CLASS
65°C
WATER PUMP
OUTPUT WATER
7 SPEEDS
HIGH TEMP
-20°C
DHW
HEATING MODE
BMS
BOILER CONNECTION
SOLAR KIT
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
INTERNET CONTROL: Optional.
49
NEW
TECHNOLOGY
AQUAREA H GENERATION HIGH PERFORMANCE
MONO‑BLOC SINGLE PHASE.
HEATING AND COOLING - MDC
The Aquarea MDC range adapts well in
an existing installation with a boiler
backup, and in a new application with
underfloor heating, low temperature
radiators or even fan-coil heaters.
This range can also be connected to a solar kit in
order to increase efficiency and minimise the
impact on the ecosystem. Finally, it is possible to
connect a thermostat for even better heating and
cooling control and management.
Whatever the weather, Aquarea can work even at
-20°C. The Mono‑bloc is easy to install in new and
existing residential properties.
Outdoor Unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Sound pressure
Heating / Cooling
Sound power level
Heating / Cooling
Dimensions
HxWxD
Weight
Refrigerant (R410A)²
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Heating
Input Power
Cooling
Heating
Running and Starting
current
Cooling
Current 1
Current 2
Recommended Fuse
Recommended cable size, supply 1 & 2
Operation range
Outdoor ambient
Heating
Water outlet
Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
PAW-3WYVLV-SI
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
dB
mm
kg
Technical focus
· NEW! Touch Controller
· Optional Smartphone control
· Range from 5 to 9kW, Single Phase
· Maximum hydraulic module output temperature:
55°C
· Works at temperatures as low as -20°C
· Cooling temperature range 5 ~ 20°C
WH-MDC05H3E5¹
5,00
5,08
4,80
3,75
4,50
2,98
4,50
3,33
i
i
49 / 47
65 / 65
865 x 1.283 x 320
107
Single Phase Heating and Cooling
WH-MDC07H3E5¹
7,00
4,46
5,00
3,45
5,15
2,68
5,50
2,74
i
i
49 / 47
65 / 65
865 x 1.283 x 320
112
WH-MDC09H3E5¹
9,00
4,15
7,45
3,14
7,70
2,12
7,00
2,44
i
i
51 / 49
69 / 67
865 x 1.283 x 320
112
1,42 / —
1,45 / —
1,45 / —
R1¼
7
34 / 96
14,3
3
0,985
1,35
4,5
6,1
19,5
13,0
30 / 15
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
R1¼
7
36 / 100
17,2
3
1,34
2,01
6,1
9,3
20,5
13,0
30 / 15
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
R1¼
7
39 / 108
25,8
3
2,17
2,87
9,9
13,0
22,9
13,0
30 / 16
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
kg / TCO2 Eq.
W
l/min
kW
kW
kW
A
A
A
A
A
mm²
°C
°C
°C
Accessories
PAW-BTANK50L
PA-AW-WIFI-1TE
PAW-A2W-BIV
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
3 way valve
Buffer tank 50L
Wifi interface
Bivalent control
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
Authorized service partner or Authorized installer can enable the cooling mode through a special operation via the remote controller on site. 1) Available in October 2017. 2) WH-MDC models are hermetically sealed. * Tentative data.
A++
ErP 55°C
A++
ErP 35°C
INTERNET CONTROL: Optional.
50
A CLASS
5,08
7 SPEEDS
HIGH PERFORMANCE
WATER PUMP
-20°C
COP
DHW
HEATING MODE
BMS
BOILER CONNECTION
SOLAR KIT
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
NEW / AQUAREA
AQUAREA G GENERATION HIGH PERFORMANCE
MONO‑BLOC SINGLE PHASE.
HEATING AND COOLING - MDC
The Aquarea MDC range adapts well in
an existing installation with a boiler
backup, and in a new application with
underfloor heating, low temperature
radiators or even fan-coil heaters.
Technical focus
· Efficient control of room temperature based on
the outdoor temperature, indoor temperature
using the Aquarea Manager.
· Optional Smartphone control
· Range from 5 to 16kW, Single Phase
· Maximum hydraulic module output temperature:
55°C
· Works at temperatures as low as -20°C
· Cooling temperature range 5 ~ 20°C
· Plug and play system (WH-MDC05F3E5)
This range can also be connected to a solar kit in
order to increase efficiency and minimise the
impact on the ecosystem. Finally, it is possible to
connect a thermostat for even better heating and
cooling control and management.
Whatever the weather, Aquarea can work even at
-20°C. The Mono‑bloc is easy to install in new and
existing residential properties.
Outdoor Unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Sound pressure
Heating / Cooling
Sound power level
Heating / Cooling
Dimensions
HxWxD
Weight
Refrigerant (R410A)¹
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Heating
Input Power
Cooling
Heating
Running and Starting
current
Cooling
Current 1
Current 2
Recommended Fuse
Recommended cable size, supply 1 & 2
Operation range
Outdoor ambient
Heating
Water outlet
Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
PAW-3WYVLV-SI
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
dB
mm
kg
kg / TCO2 Eq.
W
l/min
kW
kW
kW
A
A
A
A
A
mm²
°C
°C
°C
WH-MDC05F3E5
5,00
5,08
4,80
3,75
4,50
2,98
4,50
3,33
i
i
49 / 47
65 / 65
865 x 1.283 x 320
107
1,42 / 2,965
R1¼
7
34 / 96
14,3
3
0,985
1,35
4,5
6,1
19,5
13,0
30 / 15
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
WH-MDC06G3E5
6,00
4,46
5,00
3,45
5,15
2,68
5,50
2,74
i
i
49 / 47
65 / 65
865 x 1.283 x 320
112
1,45 / 3,028
R1¼
7
36 / 100
17,2
3
1,34
2,01
6,1
9,3
20,5
13,0
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
Single Phase Heating and Cooling
WH-MDC09G3E5
9,00
4,15
7,45
3,14
7,70
2,12
7,00
2,44
i
i
51 / 49
69 / 67
865 x 1.283 x 320
112
1,45 / 3,028
R1¼
7
39 / 108
25,8
3
2,17
2,87
9,9
13,0
22,9
13,0
30 / 16
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
20 ~ 55
5 ~ 20
Accessories
PAW-BTANK50L
PA-AW-WIFI-1TE
PAW-A2W-BIV
PAW-FILTER
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
3 way valve
WH-MDC12G6E5
12,00
4,74
11,40
3,44
10,00
2,73
10,00
2,81
i
i
52 / 50
69 / 68
1.410 x 1.283 x 320
147
2,10 / 4,385
R1¼
7
34 / 110
34,4
6
2,53
3,56
11,7
16,5
24,0
26,0
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
25 ~ 55
5 ~ 20
WH-MDC16G6E5
16,00
4,28
13,00
3,28
11,40
2,68
12,20
2,56
i
i
55 / 54
72 / 72
1.410 x 1.283 x 320
147
2,10 / 4,385
R1¼
7
38 / 120
45,9
6
3,74
4,76
17,3
22,0
26,0
26,0
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
25 ~ 55
5 ~ 20
Buffer tank 50L
Wifi interface
Bivalent control
Filter
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
Authorized service partner or Authorized installer can enable the cooling mode through a special operation via the remote controller on site. 1) WH-MDC models are hermetically sealed.
A++
ErP 55°C
A++
ErP 35°C
A CLASS
5,08
7 SPEEDS
HIGH PERFORMANCE
WATER PUMP
-20°C
COP
DHW
HEATING MODE
BMS
BOILER CONNECTION
SOLAR KIT
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
INTERNET CONTROL: Optional.
51
AQUAREA G GENERATION T‑CAP
MONO‑BLOC SINGLE PHASE / THREE PHASE.
HEATING AND COOLING - MXC
The MXC is ideal for residential
properties which don’t have an external
boiler and require a maintained capacity
level.
solar kit in order to increase efficiency and
minimise the impact on the ecosystem. Finally, it
is possible to connect a thermostat for even better
heating or cooling control and management.
T‑CAP stands for Total Capacity. This line-up is
able to maintain the same nominal capacity even
at -15°C without the help of an electrical booster
heater. T‑CAP is also able to provide extremely
high efficiency, regardless of the outside
temperature or the water temperature. The MXC
adapts well in an existing installation with a boiler
backup, and in a new application with underfloor
heating, low temperature radiators or even fan-coil
heaters. This range can also be connected to a
Technical focus
· Efficient control of room temperature based on
the outdoor temperature, indoor temperature
using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 16 kW, Single and Three Phase
· Maximum hydraulic module output temperature: 55°C
· Works at temperatures as low as -20°C
· Cooling temperature range 5 ~ 20°C
Outdoor Unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Sound pressure
Heating / Cooling
Sound power level
Heating / Cooling
Dimensions
HxWxD
Weight
Refrigerant (R410A)¹
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Heating
Input Power
Cooling
Heating
Running and Starting
current
Cooling
Current 1
Current 2
Recommended Fuse
Recommended cable size, supply 1 & 2
Operation range
Outdoor ambient
Heating
Water outlet
Cooling
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
PAW-3WYVLV-SI
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
dB
mm
kg
kg / TCO2 Eq.
W
l/min
kW
kW
kW
A
A
A
A
A
mm²
°C
°C
°C
Single Phase
WH-MXC09G3E5
WH-MXC12G6E5
9,00
12,00
4,84
4,74
9,00
12,00
3,59
3,44
9,00
12,00
2,85
2,72
7,00
10,00
3,17
2,81
i
i
i
i
51 / 49
52 / 50
68 / 67
69 / 68
1.410 x 1.283 x 320
1.410 x 1.283 x 320
148
148
2,30 / 4,802
2,30 / 4,802
R1¼
R1¼
7
7
32 / 102
34 / 110
25,8
34,4
3
6
1,86
2,53
2,21
3,56
8,6
11,7
10,2
16,5
25,0
29,0
13,0
26,0
30 / 30
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
-20 ~ +35
25 ~ 55
25 ~ 55
5 ~ 20
5 ~ 20
WH-MXC09G3E8
9,00
4,84
9,00
3,59
9,00
2,85
7,00
3,17
i
i
51 / 49
68 / 67
1.410 x 1.283 x 320
155
2,30 / 4,802
R1¼
7
32 / 102
25,8
3
1,86
2,21
2,8
3,4
14,7
13,0
16 / 16
5 x 1,5 / 3 x 1,5
-20 ~ +35
25 ~ 55
5 ~ 20
Accessories
PAW-BTANK50L
PA-AW-WIFI-1TE
PAW-A2W-BIV
PAW-FILTER
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
3 way valve
Three Phase
WH-MXC12G9E8
12,00
4,74
12,00
3,44
12,00
2,72
10,00
2,81
i
i
52 / 50
69 / 68
1.410 x 1.283 x 320
155
2,30 / 4,802
R1¼
7
34 / 110
34,4
9
2,53
3,56
3,8
5,3
11,9
13,0
16 / 16
5 x 1,5 / 5 x 1,5
-20 ~ +35
25 ~ 55
5 ~ 20
WH-MXC16G9E8
16,00
4,28
16,00
3,10
16,00
2,49
12,20
2,56
i
i
55 / 54
72 / 72
1.410 x 1.283 x 320
168
2,35 / 4,907
R1¼
7
38 / 120
45,9
9
3,74
4,76
5,7
7,2
15,5
13,0
16 / 16
5 x 1,5 / 5 x 1,5
-20 ~ +35
25 ~ 55
5 ~ 20
Buffer tank 50L
Wifi interface
Bivalent control
Filter
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C). Performance in agreement with EN14511.
1) WH-MXC models are hermetically sealed.
A++
ErP 55°C
A++
ErP 35°C
INTERNET CONTROL: Optional.
52
A CLASS
-15°C
WATER PUMP
CONSTANT HEATING
7 SPEEDS
T-CAP
-20°C
DHW
HEATING MODE
BMS
BOILER CONNECTION
SOLAR KIT
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
NEW / AQUAREA
AQUAREA G GENERATION HT
MONO‑BLOC SINGLE PHASE.
HEATING ONLY - MHF
Aquarea HT is able to deliver 65°C with
the Heat Pump alone.
For a house with high temperature radiators (for
example, cast iron radiators), the Aquarea High
Temperature Solution is most suited as it provides
output water temperatures of 65°C even at -20°C.
Technical focus
· Efficient control of room temperature based on
the outdoor temperature, indoor temperature
using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 12kW, Single and Three Phase
· Maximum hydraulic module output temperature:
65°C
· Works at temperatures as low as -20°C
Single Phase
Outdoor Unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Heating capacity at +7°C (heating water at 65°C)
COP at +7°C (heating water at 65°C)
Heating capacity at +2°C (heating water at 65°C)
COP at +2°C (heating water at 65°C)
Heating capacity at -7°C (heating water at 65°C)
COP at -7°C (heating water at 65°C)
Energy Efficiency Class at 35°C
Energy Efficiency Class at 55°C
Sound pressure
Sound power level
Dimensions
HxWxD
Weight
Refrigerant (R407C)¹
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Running and Starting current
Current 1
Current 2
Recommended Fuse
Recommended cable size, supply 1 & 2
Operation range
Outdoor ambient
Water outlet
Accessories
PAW-TD20C1E5
PAW-TD30C1E5
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
CZ-TK1
PAW-3WYVLV-SI
WH-MHF09G3E5
9,00
4,64
9,00
3,45
9,00
2,74
9,00
2,27
9,00
1,89
8,90
1,63
i
i
51
68
1.410 x 1.283 x 320
151
1,92 / 3,406
R1¼
7
—
25,8
3
1,94
9,3
28,5
13,0
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
25 ~ 65
kW
W/W
kW
W/W
kW
W/W
kW
W/W
kW
W/W
kW
W/W
dB(A)
dB
mm
kg
kg / TCO2 Eq.
W
l/min
kW
kW
A
A
A
A
mm²
°C
°C
WH-MHF12G6E5
12,00
4,46
12,00
3,26
12,00
2,52
12,00
2,22
10,30
1,84
9,60
1,62
i
i
52
69
1.410 x 1.283 x 320
151
1,92 / 3,406
R1¼
7
—
34,4
6
2,69
12,8
29,0
26,0
30 / 30
3 x 4,0 or 6,0 / 3 x 4,0
-20 ~ +35
25 ~ 65
Accessories
PAW-BTANK50L
PA-AW-WIFI-1TE
PAW-A2W-BIV
PAW-FILTER
PAW-A2W-RTWIRED
Tank 200L - Stainless steel
Tank 300L - Stainless steel
Tank 200L - Enamelled
Tank 300L - Enamelled
Temperature sensor for 3rd party tank
3 way valve
Buffer tank 50L
Wifi interface
Bivalent control
Filter
Room thermostat
COP classification is at 230V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1m from the outdoor unit and at 1,5m height. Heating sound pressure measured at +7°C (heating water at 55°C).Performance in agreement with EN14511.
1) WH-MHF models are hermetically sealed.
A++
ErP 55°C
A++
ErP 35°C
A CLASS
65°C
WATER PUMP
OUTPUT WATER
7 SPEEDS
HIGH TEMP
-20°C
DHW
HEATING MODE
BMS
BOILER CONNECTION
SOLAR KIT
INTERNET CONTROL
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
INTERNET CONTROL: Optional.
53
AQUAREA AIR RADIATORS
FAN COILS FOR HEAT PUMP APPLICATION
New line up of Super low temperature radiators for Heat Pump
application: Aquarea Air 200/700/900 with radiating effect
The slimline Panasonic Aquarea Air radiators deliver high efficiency
climate control. With a depth of just under 13 cm they are at the cutting
edge of the market. Blending easily into the home, Aquarea Air’s elegant
design and product refinements are clear to see in every detail.
The Aquarea Air’s slimline profile has been achieved thanks to the
innovative layout of the ventilation unit and the heat exchanger. The fan is
tangential with asymmetric blades and the large surface heat exchanger
enables high airflows to be achieved with low pressure loss and low noise
levels. Exceptional ventilation efficiency means the motor uses
considerably less energy (low wattage). The fan speed is continuously
modulated by the temperature controller with proportional integral logic,
with undoubted advantages for regulating the temperature and humidity in
summer mode.
With standard cast radiators.
2,0kW
Water at 65°C needed.
54
Line up of super low temperature radiators for Heat Pump
application
During winter, the operating principle is based on micro fans with very low
power consumption and minimum noise, that send hot air coming from
the heat exchanger, to the inside of the front panel of the device and
therefore heat it effectively. With this principle, the terminal also provides
significant power while heating, without running the main fan. Comfort
temperatures are therefore maintained, without air movements and in
silence. In summer mode, the airflow generated by the micro fans is
stopped to avoid any dew formation on the terminal’s front surface.
With Aquarea Air.
2,0kW
Water at 35°C needed.
Technical focus:
· Front panel heating with radiant effect
· High heating capacity (without main fan running)
· 4 fan speeds and capacities
· Exclusive design
· Extremely compact (only 12,9 cm deep)
· Cooling and dehumidification functions possible (drain is needed)
· 3-way valve included (no overflow valve needed on the installation if
more than 3 radiators installed)
· Touch screen thermostat
All temperature curves and capacity are available on
www.panasonicproclub.com
NEW / AQUAREA
During winter, the operating principle is based on micro fans with very low
power consumption and minimum noise, that send hot air coming from
the heat exchanger, to the inside of the front panel of the device and
therefore heat it effectively.
With this principle, the terminal also provides significant power while
heating, without running the main fan. Comfort temperatures are therefore
maintained, without air movements and in silence. In summer mode, the
airflow generated by the micro fans is stopped to avoid any dew formation
on the terminal’s front surface.
Operating on heating mode with radiator using only radiant effect.
Fan Coils for Heat Pump application
Total heating capacity
W
Water flow
kg/h
Water pressure drop
kPa
m³/min
Air flow
Speed
Maximum input power
W
Sound pressure
dB(A)
Inlet water temperature
°C
Outlet water temperature
°C
Inlet air temperature
°C
Outlet air temperature
°C
Dimensions (H x W x D)
mm
Weight
kg
3-ways valve included
Touch screen thermostat
470
80,8
2,0
1,9
Med
9
33,2
35
30
19
32,0
570
98,0
2,9
2,7
Max
13
39,4
35
30
19
30,0
PAW‑AAIR-700-1
223
360
708
38,4
61,9
121,8
0,1
0,1
0,3
0,7
1,4
2,6
Main Fan Off Super Min
Min
3
9
14
18,4
19,6
25,8
35
35
35
30
30
30
19
19
19
34,9
32,4
33,3
579 x 935 x 129
20
Yes
Yes
Operating on cooling mode with fan.
1.032
177,5
0,8
4,2
Med
18
34,1
35
30
19
31,8
1.188
204,3
1,0
5,3
Max
22
40,2
35
30
19
30,6
PAW‑AAIR-900-1
273
475
886
47,0
81,7
152,4
0,1
0,2
0,5
0,9
1,8
4,1
Main Fan Off Super Min
Min
3
11
16
18,4
22,3
26,2
35
35
35
30
30
30
19
19
19
34,8
32,5
30,2
579 x 1.135 x 129
23
Yes
Yes
1.420
244,2
1,6
6,1
Med
20
34,4
35
30
19
31,1
1.703
292,9
2,2
7,7
Max
24
42,2
35
30
19
30,6
129
579
659
Operating on heating mode with radiant effect and fan mode.
PAW‑AAIR-200-1
138
160
217
23,7
27,5
37,3
0,1
0,2
0,4
0,5
0,6
0,9
Main Fan Off Super Min
Min
2
5
7
17,6
18,8
24,7
35
35
35
30
30
30
19
19
19
34,5
32,6
38,9
579 x 735 x 129
17
Yes
Yes
A
Technical focus
· Front panel heating with radiant effect
· High heating capacity (without main fan running)
· 4 fan speeds and capacities
· Exclusive design
· Extremely compact (only 12,9cm deep)
· Cooling and dehumidification functions possible (drain is needed)
· 3-way valve included (no overflow valve needed on the installation if
more than 3 radiators installed)
· Touch screen thermostat
A
A
200 700 900
A 735 935 1.135
A
126
A Supports cover
55
SANITARY TANKS
A wide range of tanks adapted to every need.
Panasonic offers best combination of Aquarea with DHW. Wide range of
tanks to adapt to any specific need with high quality standards.
The wide range is covered with 1 Tank with buffer tank, 2 Stainless Tanks
with “A” Class and 5 Enamelled tanks from 150 to 400L.
Aquarea Tank. DHW tank with buffer tank.
Designed for retrofit applications, the DHW 200l tank with a 80l buffer
tank is particularly suitable for fast integration on an existing installation.
Panasonic has developed a tank with 80l Buffer tank and 200l sanitary
hot water cylinder. This tank includes a 3-way valve and an “A” Class
pump. Easy to install, nice looking, high efficiency for DHW production
and for heating.
Aquarea Tank. Tanks and buffer tank in one!
Water volume
Maximum water temperature
Dimension / Weight
HxWxD
Electric heater
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C¹
Number of speed
A class pump
Pressure drop (Min / Max)
Input power (Min / Max)
3 Way valve included
Safety thermostat with contact for failure part of E-Heating
Location of the electrical heater
Electrical backup heater on the buffer tank
56
L
°C
mm / kg
kW
V
m²
kWh/24h
kPa
W
PAW-TD20B8E3-NDS
185 (for DHW tank) / 80 (for buffer tank)
100
1.810 x 600 x 632 / 150
3
230 - 2p
Stainless steel
2,3
1,3
Stepless (800-4250 rpm)
5/6
3 / 45
Yes
Yes
Mid
Optional
NEW / AQUAREA
Stainless Steel Tank.
The best heat pump in market needs to be complemented with best
efficiency tank. Panasonic “A” Class Stainless Tank consist in 2 capacities
200 and 300L. These 2 models are anode free does not require any
maintenance.
Tanks
Stainless Steel Tank
Model
Water volume
L
Maximum water temperature
°C
Dimensions
Hight / Diameter mm
Weight / filled with water
kg
Electric heater
kW
Power supply
V
Material inside tank
Exchange surface
m²
Energy loss at 65°C¹
kWh/24h
3 Way valve accessory PAW-3WYVLV-SI or CZ-NV1
20m temperature sensor cable included
Heat up time
Valuation
Energy losses
Valuation
Energy Efficiency Class
Warranty
Maintenance required
Enamelled Tank.
With our enamelled tanks wide range, we can satisfy any size needs.
Consisting on 4 different size: 150, 200, 300 and 400L. The 300L is also
available in with 2 coils version.
Water volume
L
Maximum water temperature
°C
Dimensions
Hight / Diameter mm
Weight / filled with water
kg
Electric heater
kW
Power supply
V
Material inside tank
Exchange surface
m²
Energy loss at 65°C¹
kWh/24h
3 Way valve accessory PAW-3WYVLV-SI or CZ-NV1
20m temperature sensor cable included
Heat up time
Valuation
Energy losses
Valuation
Energy Efficiency Class
Warranty
Maintenance required
PAW-TD30C1E5
192
75
1.265 / 595
53 / —
1,5
230
Stainless steel
1,8
0,99
Optional
Yes
★★★★
★★★★
a
2 years
No
280
75
1.745 / 595
65 / —
1,5
230
Stainless steel
1,8
1,13
Optional
Yes
★★★★
★★★★
a
2 years
No
1) Insulated tested under EN12897. * Includes proportional control thermostat.
PAW-TG15C1EZ**
PAW-TG20C1E3STD-1
PAW-TG30C1E3STD-1
PAW-TG40C1E3STD-1
Enamelled 2 coils Tank (for
bivalent Solar + HP)
PAW-TG30C2E3STD-1
150
185
95
1.507 / 580
97 / 282
3
230
Enamelled
2,0
1,6
Optional
Yes
★★★★
★★★★
c
2 years
Yearly
285
95
1.565 / 680
140 / 425
3
230
Enamelled
2,5
2,1
Optional
Yes
★★★★
★★★★
c
2 years
Yearly
396
95
1.888 / 760
171 / 567
3
230
Enamelled
6,1
1,7
Optional
Yes
★★★★
★★★★
b
2 years
Yearly
284
95
1.417 / 760
134 / 418
3
230
Enamelled
2,4 (for HP) +1,0 (for solar or boiler)
1,6
Optional
Yes
★★★★
★★★★
b
2 years
Yearly
Tanks
Model
PAW-TD20C1E5
Enamelled Tank
500 x 1.345
230
Steel enamelled
1,4
Optional
c
2 years
Yearly
1) Insulated tested under EN12897. * Includes proportional control thermostat. ** Tentative image.
57
AQUAREA DHW
DHW tank with built-in Heat Pump
The Heat Pump is one of the most energy efficient and cost effective
methods of water heating. The pump is mounted on the storage tank and
draws energy from the ambient air, using that extra energy source to heat
the water up to 55°C.
All new DHW HP will be delivered with a plug, because:
1. IP protection
2. Pull forces
3. No junction box – we want to avoid to have disassembling though
installation
4. Bench mark analysis
Wall mounted Aquarea DHW. Mid Capacity: 80/100/120L
Designed for maximum energy savings, Aquarea DHW’s medium tank
volume has been designed as a perfect replacement for the electric water
heater. The conventional medium tank volume has been boosted with a
heat pump generator, which delivers superior energy performance. The airto-water heat pump design with air ducts enables the selection of inlet
and outlet points for the air, which allows it to be used in various parts of
the home (kitchen, bathroom, sunrooms, etc.).
5 years warranty for the tank himself,
all other parts have two years warranty.
58
Aquarea DHW Advantages
· High-technology rotational compressor ensures higher energy efficiency
and a higher coefficient of performance, which means major energy
savings – up to 75%.
· Wrapped around the inside of the outer cover of the tank, it prevents the
build-up of limescale, extends the useful life of the equipment and
improves safety.
· The dimensions and heating capability of a medium volume Aquarea
DHW tank can easily replace an existing electric water heater. Its small
size allows it to be installed in spaces where previously a conventional
electric water heater would be installed.
· Impressive tank protection is provided through the use of superior
super-clean enamel and a large magnesium element. These ensure
durability even in the harshest operating conditions, without harmful
additives in the water.
Floor standing at -7°C Aquarea DHW. High capacity: 200/295L
The DHW is ready to achieve levels of high efficiency even at
temperatures as low as -7°C. With this range it is possible to connect an
additional heat source, such as solar energy. In PAW‑DHWM300AE, the
heat pump cools and de-humidifies the air pumped either from outdoors
or from within the building. By choosing the point of air capture and
exhaust, you can ventilate and de-humidify some rooms, while extracting
the cooled air either into the environment or into another room that you
wish to cool.
NEW / AQUAREA
Floor standing at -7°C Aquarea DHW. High capacity: 200/295L.
Wall mounted Aquarea DHW. Mid Capacity: 80/100/120L.
Technical focus
· Energy efficiency A class
· 119,1 % Energy efficiency ηwh¹
· 1 .204,2kWh AEC annual electricity consumption¹
· 6 ,57kWh Daily electricity consumption Qelec²
· 55°C Thermostat temperature settings
· 0 Value of smart
Technical focus
· Capacity: 80, 100 and 120L
· Vertical wall mounting
· Operating range between -7°C to +35°C
· LCD touch screen display
1) EU Regulation 812/2013 ; EN 16147:2010. 2) EN 16147:2010.
Model
Reference
Volume
Dimensions of Connections
Height / with air ducts
Connections to the water supply network
Dimensions of air ducts
Net weight / with water
Heat Pump
Nominal electrical power
Reference tapping cycle
Energy consumption by chosen cycle A7 / W10-55 ¹
Energy consumption by chosen cycle A15 / W10-55 ²
COP DHW (A7 / W10-55) EN 16147 ¹
COP DHW (A15 / W10-55) EN 16147 ²
Energy Efficiency Class
Standby power input according to EN16147
Sound power / Sound Pressure on 1m
Refrigerant
Quantity of refrigerant
Operating range - air temperature
Nominal air flow rate (Maximum)
Maximum pressure drop (volumetric flow rate at 5,5m³/min (60%)
Pressure drop by 2,5m³/min (60%/80%) (Maximum) 3
Storage Tank
Enamelled steel tank / Protective magnesium anode
Average insulation thickness
External source exchanger (m² surface / connection)
Electrical Specifications
Maximum power consumption without heater / with heater
Number of electrical heaters x power
Voltage / Frequency
Electric protection
Moisture protection
Working pressure (Storage tank / Heat Exchanger)
Maximum Temperature
Heating with heat pump Min / Max
Heating with electrical heater
Refrigerant information
Refrigerant (R134a) 4
L
mm
mm / m
kg
W
kWh
kWh
W
dB / dB(A)
g
°C
m³/min
Pa
Pa
mm
W
W
V / Hz
A
Mpa (bar)
°C
°C
kg / TCO2 Eq.
PAW-DHWM200A
208
Floor standing at -7°C*
PAW-DHWM300A
295
PAW-DHWM300AE
276
PAW-DHWM80ZNT
80
Wall mounted
PAW-DHWM100ZNT
100
PAW-DHWM120ZNT
120
1.540 x 670 x 690
G1
Ø160 / —
149 / 365
1.960 x 670 x 690
G1
Ø160 / —
164 / 459
1.960 x 670 x 690
G1
Ø160 / —
207 /480
1.197 x 506 x 533
G 1/2
Ø125 (150 x 70) / 10
58 / 138
1.342 x 506 x 533
G 1/2
Ø125 (150 x 70) / 10
62 / 162
1.497 x 506 x 533
G 1/2
Ø125 (150 x 70) / 10
68 / 188
490
L
4,05
3,95
3,00
3,07
a
28
— / 58
R134a
1.100
-7 / +35
7,5
100
—
490
XL
5,77
5,65
3,33
3,39
a
18
— / 58
R134a
1.100
-7 / +35
7,5
100
—
490
XL
5,96
5,75
3,30
3,38
a
20
— / 58
R134a
1.100
-7 / +35
7,5
100
—
250
M
2,45
2,04
2,65
3,10
a
19
51,0 / 39,5
R134a
540
-7 / +35
1,7 - 3,8
—
70 (90)
250
M
2,35
2,05
2,63
3,10
a
20
51,0 / 39,5
R134a
540
-7 / +35
1,7 - 3,8
—
70 (90)
250
M
2,51
2,08
2,61
3,10
a
27
51,0 / 39,5
R134a
540
-7 / +35
1,7 - 3,8
—
70 (90)
+/+
—
—
+/+
—
—
+/+
—
2,7 / G1
+/+
40 - 85
—
+/+
40 - 85
—
+/+
40 - 85
—
490 / 2.490
2 x 1.000
230 / 50
16
IP24
0,6 (6) / 0,9 (9)
490 / 2.490
2 x 1.000
230 / 50
16
IP24
0,6 (6) / 0,9 (9)
490 / 2.490
2 x 1.000
230 / 50
16
IP24
1,0 (10)
— / 2.350
2 x 1.000
230 / 50
16
IP24
1,0 (10)
— / 2.350
2 x 1.000
230 / 50
16
IP24
1,0 (10)
— / 2.350
2 x 1.000
230 / 50
16
IP24
1,0 (10)
55 / 65
75
55 / 65
75
55 / 65
75
55 / —
75
55 / —
75
55 / —
75
1,100 / 1,573
1,100 / 1,573
1,100 / 1,573
0,540 / 0,772
0,540 / 0,772
0,540 / 0,772
1) Heating of sanitary water up to 55°C with inlet air temperature at 7°C, humidity at 89% and inlet water temperature at 10°C. According to EN16147. 2) Heating of sanitary water up to 55°C with inlet air temperature at 15°C, humidity at 74% and inlet water
temperature at 10°C. According to EN16147. 3) Normal fan speed 60%, higher fan speed - special setting on 80%. 4) Aquarea DHW units are hermetically sealed.
* When connected as pressurised, use of safety valve is mandatory.
Pressurised
High-Quality insulation
Fast heating
Air ducts
Additional heating source
Electronic regulation with
touch screen
Indirect tubular air heating
element
Vertical floor mounting
Vertical wall mounting
External exchanger
Magnezium anode corrosion
protection
59
ACCESSORIES & CONTROL
Optional PCB’s for additional
functions
CZ-NS2P
PCB for solar connection kit for Mono‑bloc systems.
CZ-NS3P
PCB for solar connection kit for Mono‑bloc systems 6kW
and 9kW.
CZ-NS4P
PCB for advanced functions in H Generation.
Hydraulic accessories
CZ-NS3P // CZ-NS2P
Deice accessories
CZ-NE1P
Base pan heater (for all old Bi‑bloc and Mono‑bloc, not for the 3 and 5kW).
CZ-NE2P
Base pan heater (for 3kW and 5kW).
CZ-NE3P
Base pan heater (for all new F Generation products: F3, F6, F9).
CZ-NS4P
CZ-NE1P
PAW-ADC-PREKIT
PAW-ADC-CV150
Accessories for Aquarea Air
PAW-AAIR-LEGS-1
Kits of 2 legs to support the Aquarea Air on the floor and to protect the water pipings.
Sanitary tank accessories
PAW-TS1
Tank sensor with 6m cable length.
PAW-TS2
Tank sensor with 20m cable length.
PAW-TS4
Tank sensor with 6m cable length and only 6mm diameter.
CZ-TK1
Temperature sensor kit for third party tank (with copper pocket and 6m length sensor cable).
PAW-HPM12ZONE-U
HPM with room sensor and setpoint adaption for
Bi‑bloc + sensors.
PAW-HPM12ZONE-M
HPM with room sensor and setpoint adaption for
Mono‑bloc + sensors.
PAW-HPM12ZONE-UF
HPM with room sensor and setpoint adaption for
F Generation Bi‑bloc and Mono‑bloc.
PAW-HPM12ZONE-MF
HPM with room sensor and setpoint adaption for
F Generation Bi‑bloc and Mono‑bloc.
PAW-HPM12ZONELCD-U
HPM with LCD wireless room thermostat for Bi‑bloc
+ sensors.
PAW-HPM12ZONELCD-M
HPM with LCD wireless room thermostat for
Mono‑bloc + sensors.
PAW-HPM12ZONELCD-UF
HPM with LCD wireless room thermostat for
F Generation Bi‑bloc and Mono‑bloc.
PAW-HPM12ZONELCD-M
HPM with LCD wireless room thermostat for
F Generation Bi‑bloc and Mono‑bloc.
Aquarea Manager accessories*
PAW-DHWE2C
2kW optional electrical heater for floor standing.
PAW-DHWE3C
3kW optional electrical heater for floor standing.
PAW-TS1 / PAW-TS2
CZ-TK1
Special outdoor supports
PAW-WTRAY
PAW-GRDSTD40
PAW-GRDBSE20
60
CZ-NV1
* Not compatible with H Generation.
Accessories for Aquarea DHW
PAW-WTRAY
Tray for condenser water compatible with base ground support.
PAW-GRDSTD40
Outdoor elevation platform.
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
(600 x 95 x 130mm, 500kg).
PAW-BTANK50L
Aquarea Manager Kits*
Accessories for All in One
PAW-ADC-PREKIT-1
Flexible pipings and wall mounting plate for All in One
H Generation.
PAW-ADC-PREKIT
Flexible pipings and wall mounting plate for All in One
G Generation.
PAW-ADC-CV150
Decorative magnetic side cover.
PAW-2PMP2ZONE
2 zone kit, hydraulic switch, manifold, 2 A-class pumps, 1 mixture valve.
PAW-A2W-2ZONECVR
2 zone kit box cover.
PAW-A2W-2ZONEKIT
2 zone kit.
PAW-A2W-2ZONEKIT
PAW-FILTER*
2 check valves + filter with 1” (no needed for H Generation).
PAW-FILTER-ONLY*
Filter with 1” (no needed for H Generation).
PAW-A2WFILTERFLOW*
Filter and water flow meter (no needed for H Generation).
PAW-BTANK50L
Buffer tank 50L
CZ-NV1
3 way valve ready for All in One H Generation (optional in internal space).
PAW-3WYVLV-SI
3 way valve.
PAW-HPM1
Aquarea Manager with LCD.
PAW-HPM2
Aquarea Manager without LCD.
PAW-HPMINT-U
Interface to connect Aquarea Manager to Heat pump Aquarea Bi‑bloc (HPM can
control all parameters from HP).
PAW-HPMINT-M
Interface to connect Aquarea Manager to Heat pump Aquarea Mono‑bloc (HPM can
control all parameters from HP).
PAW-HPMINT-F
Interface to connect Aquarea Manager to Heat pump Aquarea Mono‑bloc and
Bi‑bloc F type (HPM can control all parameters from HP).
PAW-HPMB1
Buffer tank sensor.
PAW-HPMDHW
Buffer tank sensor with well.
PAW-HPMSOL1
Buffer tank sensor solar (with higher temperature range).
PAW-HPMAH1
Water flow pipe sensor for heating circuit.
PAW-HPMR4
Room sensor + set point adaptation.
PAW-HPMED
Touch screen.
PAW-HPMLCD
LCD Display HPM Manager.
PAW-LANCABLE
Network cable.
PAW-A2WSWITCH
Network switch.
PAW-DEWPOINTSENSOR
Dew point sensor.
PAW-HPMUH
Outdoor temperature sensor.
* Not compatible with H Generation.
PAW-HPM1
PAW-HPM2
PAW-HPMED / PAW-HPMLCD
NEW / AQUAREA
Room thermostats
H Generation sensors
PAW-A2W-RTWIRED
Wired LCD room thermostat with weekly timer.
PAW-A2W-RTWIRELESS
Wireless LCD room thermostat with weekly timer.
PAW-A2W-TSOD
Outdoor ambient sensor.
PAW-A2W-TSRT
Zone room sensor.
PAW-A2W-TSBU
Buffer tank sensor.
PAW-A2W-TSHC
Zone water sensor.
PAW-A2W-TSSO
Solar sensor.
PAW-A2W-RTWIRED
PAW-A2W-RTWIRELESS
Controller*
PAW-A2W-BIV
Bivalent controller.
* Not compatible with H Generation.
Connectivity solutions
CZ-TAW1
Aquarea Smart Cloud, H Generation Internet control
through Wifi or wired LAN.
PAW-AW-KNX-H
KNX interface for H Generation.
PAW-AW-MBS-H
Modbus interface for H Generation.
PAW-AW-KNX-1i*
KNX interface.
PAW-AW-MBS-1*
Modbus interface.
PA-AW-WIFI-1TE*
IntesisHome interface with temperature sensor accessory.
PAW-A2W-TSOD
PAW-A2W-TSRT
PAW-A2W-TSHC
PAW-A2W-TSSO
PAW-A2WLOGGER
PAW-A2WCHECKER
H Generation tools
CZ-TAW1
PAW-AW-KNX-1i
PAW-AW-MBS-1
PAW-A2WLOGGER
Data Logger: With this tool we can log data
during a long period.
PAW-A2WCHECKER
Service checker: With this tool we will have a life
monitoring at our PC.
* Not compatible with H Generation.
61
PANASONIC’S AQUAREA OFFERS THE BEST
FOR YOU AND YOUR HOME
Panasonic will supply the energy label and a product fiche
for all delivered products affected by these regulations,
which sales partners, traders and contractors must use
when labelling our products.
Energy Label ErP
Fridges, dishwashers, washing machines, ovens – it all started with white
goods in the 1990s. Today, other energy-consuming appliances also carry
the European ErP energy efficiency label, such as TV sets, lighting and –
since September 2014 – even vacuum cleaners. Since 2013 the
regulations already apply to air conditioners and pumps. As of September
2015, it will also apply to room heaters, water heaters and storage water
heaters. “ErP” stands for Energy related Products.
Now, minimum energy efficiency requirements for energy efficient
solutions (the Ecodesign Directive) are also specified for manufacturers of
system and combi boilers, water heaters and DHW cylinders.
This directive, valid throughout the European Union, and the label associated
with it are intended to assist consumers in their purchasing decisions and to
help reduce private energy demand, as well as combat climate change.
Panasonic helps you to calculate the system label.
From 26th September 2015, installers can be assured that all products
manufactured after this date will be sold with the required ErP labels
which will aid installers with their paperwork. While it is the
manufacturer’s responsibility to issue their products with the required
labels, the installers will need to calculate and issue an efficiency label
for the entire heating system. Whether installing a new heating system or
installing new boilers, controls or renewables into an existing system, it
is, and will continue to be, the installer’s responsibility to calculate and
issue efficiency labels. Calculators which assist installers with this
process are available on www.panasonicproclub.com.
Manufacturer or brand
Product identifier
Symbol for space heating
DHW heating symbol with details of tapping profile
Energy efficiency scale for DHW heating
Efficiency scale for space heating
Optional symbol where operation is possible only in off-peak periods
Temperature map of Europe with three climate zones and the rated
heat output of each
Sound power level outdoors and (where relevant) indoors
62
Information on the energy label.
The rating system for heating Heat Pumps classifies them into nine
efficiency categories. The best energy efficiency category is A++. Category
G identifies appliances with significantly poorer values. The ErP label for
system boilers shows its efficiency category on a scale from A++ to G (to
D for Heat Pumps, from A to G for hot water cylinders). In August 2019, a
more rigorous scale will be introduced from A+++ to D, and from A+ to G
for hot water cylinders.
Panasonic helps you to calculate the system label
www.panasonicproclub.com
or connect simply with your smartphone to the PRO Club
using this QR
NEW / AQUAREA
A typical example of savings and performances that
Aquarea can offer to you.
A 125m² house in Reims
The example below shows a typical 3 bedroom French home and
highlights the potential savings that can be achieved with Panasonic’s
Aquarea heat pump*.
* Calculations were carried using Panasonic’s Aquarea Designer software, available from the PRO Club website
(www.panasonicproclub.com).
Calculation results
Monthly heat consumption in kWh.
Annual energy costs
Caused by heat producers
Heat pump
Hot water heating rod
Caused by heat consumers
Space heating
Service hot water
Heat circulation pump(s)
Total
1.600 €
0€
kWh
Service hot water
Type of service
Tank volume
Average daily need
Cold water inlet temperature
Target tank temperature
Exchange loss
Electrical auxiliary heating necessary
5.000
Hot water with heat pump
300 Litre
200 Litre
10°C
50°C
5K
No
4.000
3.000
2.000
1.000
0
Used Panasonic heat pump
Description
Sanitary tank
Heat pump type
Capacity / consumption at 2°C (heating water at 35°C)
Recommended flow-through of air
Maximum flow temperature
Mode of operation
Design
Number of heat pumps used
Wattage of fan (included in heat pump performance data: yes)
Power consumption of heat circulation pump(s)
Building data
Address
Building area
Standard heating requirement
Internal gains
Solar gains (windows)
Indoor design temperature
Outdoor temperature limit for heating 'ON'
Heat distribution
Maximum flow water temperature
Maximum return water temperature
Solar collector area
Rate data
Description
Shut off times total
Weekends with shut off times
Daytime rate of heat pump
Nighttime rate of heat pump
Heat circulation pump(s)
Heating element for monoenergetic operation
Heating element for post heating of hot water
Climatic data
Climatic location
Monthly average temperatures in°C
1.220 €
225 €
155 €
1.600 €
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating
T-CAP 12kW
Stainless steel 300L
Air / Water
Heat: 11,7kW, Electric: 3,4kW
80,0m³/min
55°C
Monovalent
-5,0°C
1
60W
180W
Reims (French)
125m²
11,3kW
5.625kWh/year
4.500kWh/year
20°C
15°C
Underfloor heating by 100 %
Radiator heating by -- %
Wall heating by -- %
55°C
50°C
-- m²
Hot water
Aquarea energy coverage.
kW
12,00
10,00
8,00
Environment energy
6,00
4,00
Drive energy
2,00
0
-5
-1
3
Outdoor temperature (°C). Additional energy
7
11
Comparison of running costs.
Operational costs
Type of heating
Heat pump
Oil
Gas
Wood heating
Electric night storage heater
Electric heating element
Price in pence /kWh
6,5
4,0
5,0
12,0
14,0
Efficiency (%)
85
90
80
100
100
Additional costs in €/year
0
0
0
0
0
0
Total costs in €/year
1.600
3.050
1.868
2.539
4.455
5.197
kW
5.000
4.000
3.000
French (Panasonic)
0,0 h/day
Yes
Time for daytime rate
5-19 o’clock
Time for nighttime rate
19-5 o’clock
Like heat pump: yes
Like heat pump: yes
Like heat pump: yes
2.000
1.000
0
Aquarea
Heat Pump
14,0 pence/kWh
14,0 pence/kWh
-- pence/kWh
-- pence/kWh
-- pence/kWh
Reims (FR)
Jan3,4 Apr8,0 Jul16,0 Oct10,4
Feb3,6 May11,2 Aug15,9 Nov6,7
Mar5,7 Jun14,1 Sep13,7 Dec4,6
Oil
Gas
Wood heating
Night heater
Electric direct
Comparison of CO2 emissions.
Comparison of CO2 savings.
kg/year
kg/year
18.000
12.000
12.000
8.000
6.000
4.000
0
Aquarea
Heat Pump
Oil
Gas
Night
heater
Electric
direct
0
Oil
Gas
Night
heater
Electric
direct
63
HEATING & COOLING
CAPACITY TABLES
Based on outlet temperature and outside temperature.
Heating capacity table
Aquarea H Generation High Performance Bi‑bloc Single Phase. Heating and Cooling
WH-UD03HE5-1 / WH-UD03HE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
3,20
1,26
2,54
3,20
1,39
2,30
-15
3,20
1,08
2,96
3,20
1,19
2,69
-7
3,20
0,82
3,90
3,20
0,90
3,56
2
3,20
0,58
5,52
3,20
0,64
5,00
7
3,20
0,50
6,40
3,20
0,55
5,82
16
3,20
0,42
7,62
3,20
0,46
6,96
25
WH-UD05HE5-1 / WH-UD05HE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
4,20
1,75
2,40
4,20
1,94
2,16
-15
4,20
1,46
2,88
4,20
1,62
2,59
-7
4,20
1,22
3,44
4,20
1,35
3,11
2
5,00
0,97
5,15
5,00
1,08
4,63
7
5,00
0,83
6,02
5,00
0,92
5,43
16
5,00
0,74
6,76
5,00
0,82
6,10
25
WH-UD07HE5-1 / WH-UD07HE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
—
—
—
4,60
1,98
2,32
-15
—
—
—
5,15
1,92
2,68
-7
—
—
—
6,55
1,96
3,34
2
—
—
—
7,00
1,57
4,46
7
—
—
—
7,00
0,97
7,22
25
WH-UD09HE5-1 / WH-UD09HE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
—
—
—
5,90
2,66
2,22
-15
—
—
—
5,90
2,34
2,52
-7
—
—
—
6,70
2,14
3,13
2
—
—
—
9,00
2,18
4,13
7
—
—
—
9,00
1,26
7,14
25
HC
40
3,10
3,20
3,20
3,20
3,20
3,20
IP
40
1,52
1,34
1,03
0,77
0,64
0,55
COP
40
2,04
2,39
3,11
4,16
5,00
5,82
HC
45
3,00
3,20
3,20
3,20
3,20
3,20
IP
45
1,64
1,48
1,16
0,89
0,72
0,63
COP
45
1,83
2,16
2,76
3,60
4,44
5,08
HC
50
2,80
3,20
3,20
3,20
3,20
3,20
IP
50
1,78
1,67
1,33
1,05
0,86
0,73
COP
50
1,57
1,92
2,41
3,05
3,72
4,38
HC
55
2,75
3,20
3,20
3,20
3,20
3,20
IP
55
1,92
1,86
1,49
1,20
0,99
0,82
COP
55
1,43
1,72
2,15
2,67
3,23
3,90
HC
40
3,80
4,00
4,20
5,00
5,00
5,00
IP
40
1,96
1,72
1,50
1,28
1,15
1,02
COP
40
1,94
2,33
2,80
3,91
4,35
4,90
HC
45
3,40
3,80
4,20
5,00
5,00
5,00
IP
45
1,98
1,82
1,65
1,48
1,38
1,22
COP
45
1,72
2,09
2,55
3,38
3,62
4,10
HC
50
3,20
3,70
4,15
5,00
5,00
5,00
IP
50
2,05
1,95
1,86
1,68
1,53
1,35
COP
50
1,56
1,90
2,23
2,98
3,27
3,70
HC
55
3,00
3,55
4,10
5,00
5,00
5,00
IP
55
2,12
2,08
2,07
1,89
1,68
1,49
COP
55
1,42
1,71
1,98
2,65
2,98
3,36
HC
40
4,60
5,08
6,58
7,00
6,74
IP
40
2,19
2,14
2,29
1,84
1,14
COP
40
2,10
2,37
2,87
3,80
5,91
HC
45
4,60
5,00
6,60
7,00
6,48
IP
45
2,40
2,36
2,62
2,10
1,31
COP
45
1,92
2,12
2,52
3,33
4,95
HC
50
4,55
4,90
6,30
6,90
6,24
IP
50
2,63
2,45
2,82
2,35
1,43
COP
50
1,73
2,00
2,23
2,94
4,36
HC
55
4,50
4,80
6,00
6,80
6,00
IP
55
2,86
2,54
3,01
2,59
1,55
COP
55
1,57
1,89
1,99
2,63
3,87
HC
40
5,65
5,85
6,65
9,00
8,66
IP
40
2,82
2,61
2,38
2,49
1,48
COP
40
2,00
2,24
2,79
3,61
5,85
HC
45
5,40
5,80
6,60
9,00
8,32
IP
45
2,98
2,88
2,62
2,79
1,69
COP
45
1,81
2,01
2,52
3,23
4,92
HC
50
5,20
5,80
6,30
8,95
8,03
IP
50
3,08
2,98
2,82
3,25
1,85
COP
50
1,69
1,95
2,23
2,75
4,34
HC
55
5,00
5,80
6,00
8,90
7,74
IP
55
3,18
3,08
3,01
3,70
2,01
COP
55
1,57
1,88
1,99
2,41
3,85
Cooling capacity table
Aquarea H Generation High Performance Bi‑bloc Single Phase. Heating and Cooling
WH-UD03HE5-1 / WH-UD03HE5
Tamb
CC
IP
EER
LWC
7
7
7
2,40
0,42
5,71
18
3,20
0,73
4,38
25
3,20
1,04
3,08
35
2,90
1,20
2,42
43
WH-UD05HE5-1 / WH-UD05HE5
Tamb
CC
IP
EER
LWC
7
7
7
4,50
0,89
5,06
18
5,00
1,43
3,50
25
4,50
1,67
2,69
35
3,30
1,53
2,16
43
WH-UD07HE5-1 / WH-UD07HE5
Tamb
CC
IP
EER
LWC
7
7
7
4,80
0,80
6,00
18
7,00
1,90
3,68
25
6,00
2,28
2,63
35
4,85
2,65
1,83
43
WH-UD09HE5-1 / WH-UD09HE5
Tamb
CC
IP
EER
LWC
7
7
7
5,40
1,00
5,40
18
7,85
2,40
3,27
25
7,00
2,88
2,43
35
5,20
2,85
1,82
43
CC
14
4,40
4,10
3,90
3,50
IP
14
0,73
0,86
1,07
1,20
EER
14
6,03
4,77
3,64
2,92
CC
18
3,70
3,50
3,30
3,00
IP
18
0,49
0,59
0,74
0,88
EER
18
7,55
5,93
4,46
3,41
CC
14
5,00
6,30
5,50
4,10
IP
14
0,90
1,50
1,68
1,52
EER
14
5,56
4,20
3,27
2,70
CC
18
5,70
5,40
5,00
4,40
IP
18
0,90
1,06
1,33
1,53
EER
18
6,33
5,09
3,76
2,88
CC
14
7,20
8,47
6,60
6,00
IP
14
1,16
1,78
2,48
2,82
EER
14
6,21
4,76
2,66
2,13
CC
18
6,00
6,00
6,00
4,80
IP
18
1,13
1,27
1,68
1,98
EER
18
5,31
4,72
3,57
2,42
CC
14
8,40
10,20
7,60
6,99
IP
14
1,62
2,46
3,20
3,84
EER
14
5,19
4,15
2,38
1,82
CC
18
7,00
7,00
7,00
5,60
IP
18
1,61
1,77
2,15
2,55
EER
18
4,35
3,95
3,26
2,20
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
64
NEW / AQUAREA
Heating capacity table
Aquarea H Generation High Performance Bi‑bloc Three Phase. Heating and Cooling
WH-UD09HE8
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
8,65
3,06
2,83
8,30
3,21
2,59
-15
9,35
2,91
3,21
9,00
3,16
2,85
-7
9,31
2,35
3,96
9,00
2,51
3,59
2
9,00
1,54
5,84
9,00
1,86
4,84
7
9,00
1,05
8,57
9,00
1,24
7,26
25
WH-UD12HE8
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
9,30
3,46
2,69
8,90
3,62
2,46
-15
10,40
3,37
3,09
10,00
3,66
2,73
-7
11,80
3,10
3,81
11,40
3,31
3,44
2
12,00
2,10
5,71
12,00
2,53
4,74
7
12,00
1,38
8,70
12,00
1,66
7,23
25
WH-UD16HE8
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
10,60
4,09
2,59
10,30
4,38
2,35
-15
11,90
4,03
2,95
11,40
4,43
2,57
-7
13,50
3,74
3,61
13,00
3,96
3,28
2
16,00
3,21
4,98
16,00
3,74
4,28
7
16,00
2,31
6,93
16,00
2,69
5,95
25
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,41
3,54
2,78
2,16
1,44
COP
40
2,33
2,50
3,24
4,17
6,06
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,61
3,92
3,05
2,46
1,64
COP
45
2,11
2,22
2,95
3,66
5,16
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,71
3,89
3,49
2,76
1,82
COP
50
1,93
2,13
2,55
3,26
4,55
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,81
3,86
3,94
3,06
2,00
COP
55
1,76
2,05
2,23
2,94
4,05
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,79
3,95
3,53
2,96
1,94
COP
40
2,24
2,43
3,12
4,05
6,08
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,95
4,24
3,74
3,39
2,23
COP
45
2,05
2,17
2,83
3,54
5,25
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,05
4,26
3,94
3,78
2,49
COP
50
1,85
2,04
2,49
3,17
4,62
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,16
4,27
4,14
4,16
2,74
COP
55
1,68
1,92
2,20
2,88
4,16
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,67
4,83
4,18
4,27
3,07
COP
40
2,14
2,24
2,97
3,75
5,21
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
4,96
5,22
4,40
4,80
3,45
COP
45
1,96
1,97
2,70
3,33
4,64
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,94
5,09
4,46
5,11
3,67
COP
50
1,78
1,89
2,42
2,97
4,36
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,91
4,95
4,51
5,41
3,89
COP
55
1,61
1,82
2,17
2,68
4,09
Cooling capacity table
Aquarea H Generation High Performance Bi‑bloc Three Phase. Heating and Cooling
WH-UD09HE8
Tamb
CC
IP
EER
LWC
7
7
7
7,50
1,15
6,52
16
8,35
1,77
4,72
25
7,00
2,23
3,14
35
5,52
2,54
2,17
43
WH-UD12HE8
Tamb
CC
IP
EER
LWC
7
7
7
7,86
1,18
6,66
16
12,08
2,90
4,17
25
10,00
2,56
3,91
35
7,80
3,80
2,05
43
WH-UD16HE8
Tamb
CC
IP
EER
LWC
7
7
7
9,20
1,62
5,68
16
14,40
3,92
3,67
25
12,20
4,76
2,56
35
7,75
3,40
2,28
43
CC
14
9,10
10,90
8,30
7,69
IP
14
1,20
1,78
2,32
2,77
EER
14
7,58
6,12
3,58
2,78
CC
18
7,00
7,00
7,00
5,60
IP
18
1,13
1,24
1,52
1,80
EER
18
6,19
5,65
4,61
3,11
CC
14
13,15
15,70
12,00
11,10
IP
14
1,40
2,05
2,67
3,19
EER
14
9,39
7,66
4,49
3,48
CC
18
10,00
10,00
10,00
8,00
IP
18
1,73
1,97
2,40
2,85
EER
18
5,78
5,08
4,17
2,81
CC
14
16,40
19,20
15,00
13,80
IP
14
2,58
3,83
4,98
5,95
EER
14
6,36
5,01
3,01
2,32
CC
18
12,20
12,20
12,20
9,70
IP
18
2,45
2,79
2,96
4,00
EER
18
4,98
4,37
4,12
2,43
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
65
HEATING & COOLING
CAPACITY TABLES
Based on outlet temperature and outside temperature.
Heating capacity table
Aquarea All in One H Generation T-CAP Bi‑bloc Three Phase. Heating and Cooling
WH-UX09HE8
Tamb
LWC
-15
-7
2
7
25
WH-UX12HE8
Tamb
LWC
-15
-7
2
7
25
WH-UX16HE8
Tamb
LWC
-15
-7
2
7
16
25
HC
30
9,00
9,00
9,00
9,00
13,60
IP
30
3,24
2,71
2,36
1,64
1,50
COP
30
2,78
3,32
3,81
5,49
9,07
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,51
3,16
2,51
1,86
1,71
COP
35
2,56
2,85
3,59
4,84
7,95
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,91
3,62
2,78
2,16
1,93
COP
40
2,30
2,49
3,24
4,17
6,84
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,30
4,07
3,05
2,46
2,14
COP
45
2,09
2,21
2,95
3,66
5,98
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,73
4,27
3,56
2,76
2,41
COP
50
1,90
2,11
2,53
3,26
4,98
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,16
4,46
4,07
3,06
2,67
COP
55
1,74
2,02
2,21
2,94
4,19
HC
30
12,00
12,00
12,00
12,00
13,60
IP
30
4,75
3,85
3,19
2,18
1,55
COP
30
2,53
3,12
3,76
5,50
8,77
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
4,96
4,41
3,49
2,53
1,76
COP
35
2,42
2,72
3,44
4,74
7,73
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,41
4,98
3,87
2,96
2,10
COP
40
2,22
2,41
3,10
4,05
6,38
HC
45
12,00
12,00
12,00
12,00
13,20
IP
45
5,86
5,54
4,25
3,39
2,43
COP
45
2,05
2,17
2,82
3,54
5,43
HC
50
11,80
12,00
12,00
12,00
12,60
IP
50
6,24
5,90
4,86
3,78
2,66
COP
50
1,89
2,03
2,47
3,17
4,74
HC
55
11,60
12,00
12,00
12,00
12,00
IP
55
6,62
6,26
5,47
4,16
2,89
COP
55
1,75
1,92
2,19
2,88
4,15
HC
30
16,00
16,00
16,00
16,00
16,00
16,00
IP
30
6,30
5,85
4,67
3,35
2,59
2,02
COP
30
2,54
2,74
3,43
4,78
6,18
7,92
HC
35
16,00
16,00
16,00
16,00
16,00
16,00
IP
35
6,89
6,42
5,21
3,74
3,18
2,58
COP
35
2,32
2,49
3,07
4,28
5,03
6,20
HC
40
16,00
16,00
16,00
16,00
16,00
16,00
IP
40
7,45
7,00
5,74
4,30
3,71
2,91
COP
40
2,15
2,29
2,79
3,72
4,31
5,50
HC
45
16,00
16,00
16,00
16,00
16,00
16,00
IP
45
8,10
7,57
6,31
4,80
4,27
3,36
COP
45
1,98
2,11
2,54
3,33
3,75
4,76
HC
50
16,00
16,00
16,00
16,00
16,00
16,00
IP
50
8,48
8,10
6,90
5,43
4,86
3,74
COP
50
1,89
1,98
2,32
2,95
3,29
4,28
HC
55
15,20
16,00
16,00
16,00
16,00
16,00
IP
55
8,96
8,62
7,50
5,91
5,22
4,00
COP
55
1,70
1,86
2,13
2,71
3,07
4,00
Cooling capacity table
Aquarea All in One H Generation T-CAP Bi‑bloc Three Phase. Heating and Cooling
WH-UX09HE8
Tamb
LWC
18
25
35
43
WH-UX12HE8
Tamb
LWC
18
25
35
43
WH-UX16HE8
Tamb
LWC
18
25
35
43
CC
7
7,00
7,65
7,00
6,25
IP
7
1,36
1,91
2,21
2,66
EER
7
5,15
4,01
3,17
2,35
CC
18
—
—
—
—
IP
18
—
—
—
—
EER
18
—
—
—
—
CC
7
7,50
8,90
10,00
8,00
IP
7
1,41
2,16
3,56
3,01
EER
7
5,32
4,12
2,81
2,66
CC
18
—
—
—
—
IP
18
—
—
—
—
EER
18
—
—
—
—
CC
7
8,50
14,00
12,20
7,10
IP
7
1,70
4,00
4,76
3,31
EER
7
5,00
3,50
2,56
2,15
CC
18
10,00
14,00
12,20
9,80
IP
18
1,70
2,94
3,50
3,31
EER
18
5,88
4,76
3,49
2,96
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
66
NEW / AQUAREA
Heating capacity table
Aquarea High Performance Bi‑bloc Single Phase / Three Phase. Heating and Cooling
WH-UD09FE8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
8,65
3,06
2,83
8,30
3,21
2,59
7,95
-15
9,35
2,91
3,21
9,00
3,16
2,85
8,85
-7
9,31
2,35
3,96
9,00
2,51
3,59
9,00
2
9,00
1,54
5,84
9,00
1,86
4,84
9,00
7
9,00
1,05
8,57
9,00
1,24
7,26
8,73
25
WH-UD12FE5 / WH-UD12FE8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
9,30
3,46
2,69
8,90
3,62
2,46
8,50
-15
10,40
3,37
3,09
10,00
3,66
2,73
9,60
-7
11,80
3,10
3,81
11,40
3,31
3,44
11,00
2
12,00
2,10
5,71
12,00
2,53
4,74
12,00
7
12,00
1,38
8,70
12,00
1,66
7,23
11,80
25
WH-UD16FE5 / WH-UD12FE8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
10,60
4,09
2,59
10,30
4,38
2,35
10,00
-15
11,90
4,03
2,95
11,40
4,43
2,57
10,80
-7
13,50
3,74
3,61
13,00
3,96
3,28
12,40
2
16,00
3,21
4,98
16,00
3,74
4,28
16,00
7
16,00
2,31
6,93
16,00
2,69
5,95
16,00
25
IP
40
3,41
3,54
2,78
2,16
1,44
COP
40
2,33
2,50
3,24
4,17
6,06
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,61
3,92
3,05
2,46
1,64
COP
45
2,11
2,21
2,95
3,66
5,16
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,71
3,89
3,49
2,76
1,82
COP
50
1,93
2,13
2,55
3,26
4,55
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,81
3,86
3,94
3,06
2,00
COP
55
1,76
2,05
2,23
2,94
4,05
IP
40
3,79
3,95
3,53
2,96
1,94
COP
40
2,24
2,43
3,12
4,05
6,08
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,95
4,24
3,74
3,39
2,23
COP
45
2,05
2,17
2,83
3,54
5,25
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,05
4,26
3,94
3,78
2,49
COP
50
1,85
2,04
2,49
3,17
4,62
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,16
4,27
4,14
4,16
2,74
COP
55
1,68
1,92
2,20
2,88
4,16
IP
40
4,67
4,83
4,18
4,27
3,07
COP
40
2,14
2,24
2,97
3,75
5,21
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
4,96
5,22
4,40
4,80
3,45
COP
45
1,96
1,97
2,70
3,33
4,64
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,94
5,09
4,46
5,11
3,67
COP
50
1,78
1,89
2,42
2,97
4,36
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,91
4,95
4,51
5,41
3,89
COP
55
1,61
1,82
2,17
2,68
4,09
IP
18
1,13
1,24
1,52
1,80
EER
18
6,19
5,65
4,61
3,11
CC
7
7,86
12,08
10,00
7,80
IP
7
1,18
2,90
2,56
3,80
EER
7
6,66
4,17
3,91
2,05
WH-UD12FE5 / WH-UD12FE8
CC
IP
EER
14
14
14
13,15
1,40
9,39
15,70
2,05
7,66
12,00
2,67
4,49
11,10
3,19
3,48
CC
18
10,00
10,00
10,00
8,00
IP
18
1,73
1,97
2,40
2,85
EER
18
5,78
5,08
4,17
2,81
IP
18
2,45
2,79
2,96
4,00
EER
18
4,98
4,37
4,12
2,43
Cooling capacity table
Aquarea High Performance Bi‑bloc Single Phase / Three Phase. Heating and Cooling
Models
WH-UD09FE8
Tamb
CC
IP
EER
CC
IP
EER
CC
LWC
7
7
7
14
14
14
18
7,50
1,15
6,52
9,10
1,20
7,58
7,00
18
8,35
1,77
4,72
10,90
1,78
6,12
7,00
25
7,00
2,23
3,14
8,30
2,32
3,58
7,00
35
5,52
2,54
2,17
7,69
2,77
2,78
5,60
43
Models
WH-UD16FE5 / WH-UD12FE8
Tamb
CC
IP
EER
CC
IP
EER
CC
LWC
7
7
7
14
14
14
18
9,20
1,62
5,68
16,40
2,58
6,36
12,20
18
14,40
3,92
3,67
19,20
3,83
5,01
12,20
25
12,20
4,76
2,56
15,00
4,98
3,01
12,20
35
7,75
3,40
2,28
13,80
5,95
2,32
9,70
43
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
Hydraulic Pump Performance of the F type Heat Pumps: A class pump F (5kW and 16kW).
Hydraulic Pump Performance of the F type Heat Pumps: A class pump F (5kW and 16kW).
External Static Pressure (kPa)
Power consumption (W)
120
200
100
80
60
160
6
5
4
120
80
2
1
20
0
7
6
3
40
0
7
4
40
10
20
30
40
50
0
1
0
10
20
Water Flow Rate (L/min)
Min
5
3
Pump Speed 1
Pump Speed 2
30
2
40
50
60
70
Water Flow Rate (L/min)
Pump Speed 3
Pump Speed 4
Pump Speed 5
Pump Speed 6
Max
67
HEATING & COOLING
CAPACITY TABLES
Based on outlet temperature and outside temperature.
Heating capacity table
Aquarea T‑CAP Bi‑bloc Single Phase. Heating and Cooling
WH-UX09FE5
Tamb
HC
IP
COP
HC
LWC
30
30
30
35
9,00
3,24
2,78
9,00
-15
9,00
2,71
3,32
9,00
-7
9,00
2,36
3,81
9,00
2
9,00
1,64
5,49
9,00
7
13,60
1,50
9,07
13,60
25
WH-UX12FE5
Tamb
HC
IP
COP
HC
LWC
30
30
30
35
12,00
4,75
2,53
12,00
-15
12,00
3,85
3,12
12,00
-7
12,00
3,19
3,76
12,00
2
12,00
2,18
5,50
12,00
7
13,60
1,55
8,77
13,60
25
IP
35
3,51
3,16
2,51
1,86
1,71
COP
35
2,56
2,85
3,59
4,84
7,95
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,91
3,62
2,78
2,16
1,93
COP
40
2,30
2,49
3,24
4,17
6,84
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,30
4,07
3,05
2,46
2,14
COP
45
2,09
2,21
2,95
3,66
5,98
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,73
4,27
3,56
2,76
2,41
COP
50
1,90
2,11
2,53
3,26
4,98
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,16
4,46
4,07
3,06
2,67
COP
55
1,74
2,02
2,21
2,94
4,19
IP
35
4,96
4,41
3,49
2,53
1,76
COP
35
2,42
2,72
3,44
4,74
7,73
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,17
4,98
3,87
2,96
2,10
COP
40
2,22
2,41
3,10
4,05
6,38
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,38
5,54
4,25
3,39
2,43
COP
45
2,04
2,17
2,82
3,54
5,43
HC
50
10,80
12,00
12,00
12,00
12,60
IP
50
5,82
5,90
4,86
3,78
2,66
COP
50
1,86
2,03
2,47
3,17
4,74
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,26
6,26
5,47
4,16
2,89
COP
55
1,68
1,92
2,19
2,88
4,15
Cooling capacity table
Aquarea T‑CAP Bi‑bloc Single Phase. Heating and Cooling
WH-UX09FE5
Tamb
CC
IP
LWC
7
7
7,00
1,36
18
7,65
1,91
25
7,00
2,21
35
6,25
2,66
43
WH-UX12FE5
Tamb
CC
IP
LWC
7
7
10,00
1,75
18
11,20
2,67
25
10,00
3,56
35
8,00
3,35
43
EER
7
5,15
4,01
3,17
2,35
CC
14
8,55
11,10
9,23
8,55
IP
14
1,41
1,98
2,37
2,71
EER
14
6,06
5,61
3,89
3,15
CC
18
7,00
7,00
7,00
5,60
IP
18
1,00
1,10
1,35
1,60
EER
18
7,00
6,36
5,19
3,50
EER
7
5,71
4,19
2,81
2,39
CC
14
13,20
16,50
12,55
10,00
IP
14
1,96
3,01
3,63
3,46
EER
14
6,73
5,48
3,46
2,89
CC
18
10,00
10,00
10,00
8,00
IP
18
1,40
1,60
1,95
2,30
EER
18
7,14
6,25
5,13
3,48
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
68
NEW / AQUAREA
Heating capacity table
Aquarea HT Bi‑bloc Single Phase / Three Phase. Heating Only
WH-UH09FE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
9,00
3,46
2,60
9,00
3,71
2,43
-15
9,00
3,06
2,94
9,00
3,29
2,74
-7
9,00
2,43
3,70
9,00
2,61
3,45
2
9,00
1,82
4,95
9,00
1,94
4,64
7
9,00
1,46
6,16
9,00
1,56
5,77
16
12,00
1,66
7,23
12,00
1,76
6,82
25
WH-UH12FE5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
12,00
5,16
2,33
12,00
5,53
2,17
-15
12,00
4,43
2,71
12,00
4,76
2,52
-7
12,00
3,42
3,51
12,00
3,68
3,26
2
12,00
2,52
4,76
12,00
2,69
4,46
7
12,00
2,03
5,91
12,00
2,17
5,53
16
12,00
1,66
7,23
12,00
1,76
6,82
25
WH-UH09FE8
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
9,00
3,46
2,60
9,00
3,71
2,43
-15
9,00
3,06
2,94
9,00
3,29
2,74
-7
9,00
2,43
3,70
9,00
2,61
3,45
2
9,00
1,82
4,95
9,00
1,94
4,64
7
9,00
1,46
6,16
9,00
1,56
5,77
16
12,00
1,66
7,23
12,00
1,76
6,82
25
WH-UH12FE8
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
12,00
5,16
2,33
12,00
5,53
2,17
-15
12,00
4,43
2,71
12,00
4,76
2,52
-7
12,00
3,42
3,51
12,00
3,68
3,26
2
12,00
2,52
4,76
12,00
2,69
4,46
7
12,00
2,03
5,91
12,00
2,17
5,53
16
12,00
1,66
7,23
12,00
1,76
6,82
25
HC
40
9,00
9,00
9,00
9,00
9,00
12,00
IP
40
4,01
3,56
2,91
2,21
1,81
2,01
COP
40
2,24
2,53
3,09
4,07
4,97
5,97
HC
45
8,80
8,90
9,00
9,00
8,90
10,80
IP
45
4,26
3,83
3,21
2,46
2,02
2,14
COP
45
2,07
2,32
2,80
3,66
4,41
5,05
HC
50
8,60
8,90
9,00
9,00
8,80
10,60
IP
50
4,61
4,11
3,55
2,76
2,31
2,46
COP
50
1,87
2,17
2,54
3,26
3,81
4,31
HC
55
8,50
8,90
9,00
9,00
8,60
10,20
IP
55
4,91
4,46
3,88
3,06
2,52
2,66
COP
55
1,73
2,00
2,32
2,94
3,41
3,83
HC
60
8,00
8,90
9,00
9,00
8,20
9,80
IP
60
5,06
4,96
4,35
3,46
2,77
2,89
COP
60
1,58
1,79
2,07
2,60
2,96
3,39
HC
65
7,80
8,90
9,00
9,00
8,20
9,60
IP
65
5,86
5,46
4,76
3,96
3,18
3,31
COP
65
1,33
1,63
1,89
2,27
2,58
2,90
HC
40
11,00
11,50
11,50
12,00
12,00
12,00
IP
40
5,51
4,91
3,86
3,06
2,52
2,01
COP
40
2,00
2,34
2,98
3,92
4,76
5,97
HC
45
10,60
11,20
11,30
12,00
12,00
11,80
IP
45
5,53
5,06
4,14
3,44
2,86
2,41
COP
45
1,92
2,21
2,73
3,49
4,20
4,90
HC
50
10,30
10,80
11,00
12,00
11,50
11,20
IP
50
5,63
5,16
4,51
3,81
3,19
2,64
COP
50
1,83
2,09
2,44
3,15
3,61
4,24
HC
55
9,70
10,10
10,80
12,00
11,50
10,80
IP
55
5,76
5,28
4,86
4,28
3,48
2,86
COP
55
1,68
1,91
2,22
2,80
3,30
3,78
HC
60
9,00
10,00
10,65
12,00
11,00
10,50
IP
60
6,01
5,66
5,31
4,76
3,82
3,11
COP
60
1,50
1,77
2,01
2,52
2,88
3,38
HC
65
8,00
9,60
10,30
12,00
11,00
10,30
IP
65
6,11
5,91
5,59
5,41
4,37
3,62
COP
65
1,31
1,62
1,84
2,22
2,52
2,85
HC
40
9,00
9,00
9,00
9,00
9,00
12,00
IP
40
4,01
3,56
2,91
2,21
1,81
2,01
COP
40
2,24
2,53
3,09
4,07
4,97
5,97
HC
45
8,80
8,90
9,00
9,00
8,90
10,80
IP
45
4,26
3,83
3,21
2,46
2,02
2,14
COP
45
2,07
2,32
2,80
3,66
4,41
5,05
HC
50
8,60
8,90
9,00
9,00
8,80
10,60
IP
50
4,61
4,11
3,55
2,76
2,31
2,46
COP
50
1,87
2,17
2,54
3,26
3,81
4,31
HC
55
8,50
8,90
9,00
9,00
8,60
10,20
IP
55
4,91
4,46
3,88
3,06
2,52
2,66
COP
55
1,73
2,00
2,32
2,94
3,41
3,83
HC
60
8,00
8,90
9,00
9,00
8,20
9,80
IP
60
5,06
4,96
4,35
3,46
2,77
2,89
COP
60
1,58
1,79
2,07
2,60
2,96
3,39
HC
65
7,80
8,90
9,00
9,00
8,20
9,60
IP
65
5,86
5,46
4,76
3,96
3,18
3,31
COP
65
1,33
1,63
1,89
2,27
2,58
2,90
HC
40
11,00
11,50
11,50
12,00
12,00
12,00
IP
40
5,51
4,91
3,86
3,06
2,52
2,01
COP
40
2,00
2,34
2,98
3,92
4,76
5,97
HC
45
10,60
11,20
11,30
12,00
12,00
11,80
IP
45
5,53
5,06
4,14
3,44
2,86
2,41
COP
45
1,92
2,21
2,73
3,49
4,20
4,90
HC
50
10,30
10,80
11,00
12,00
11,50
11,20
IP
50
5,63
5,16
4,51
3,81
3,19
2,64
COP
50
1,83
2,09
2,44
3,15
3,61
4,24
HC
55
9,70
10,10
10,80
12,00
11,50
10,80
IP
55
5,76
5,28
4,86
4,28
3,48
2,86
COP
55
1,68
1,91
2,22
2,80
3,30
3,78
HC
60
9,00
10,00
10,65
12,00
11,00
10,50
IP
60
6,01
5,66
5,31
4,76
3,82
3,11
COP
60
1,50
1,77
2,01
2,52
2,88
3,38
HC
65
8,00
9,60
10,30
12,00
11,00
10,30
IP
65
6,11
5,91
5,59
5,41
4,37
3,62
COP
65
1,31
1,62
1,84
2,22
2,52
2,85
Hydraulic Pump Performance of the F type Heat Pumps: A class pump F (5kW and 16kW).
Hydraulic Pump Performance of the F type Heat Pumps: A class pump F (5kW and 16kW).
External Static Pressure (kPa)
Power consumption (W)
120
200
100
80
60
160
6
5
4
120
80
2
1
20
0
7
6
3
40
0
7
4
40
10
20
30
40
50
0
1
0
10
20
Water Flow Rate (L/min)
Min
5
3
Pump Speed 1
Pump Speed 2
30
2
40
50
60
70
Water Flow Rate (L/min)
Pump Speed 3
Pump Speed 4
Pump Speed 5
Pump Speed 6
Max
69
HEATING & COOLING
CAPACITY TABLES
Based on outlet temperature and outside temperature.
Heating capacity table
Aquarea G Generation High Performance Mono‑bloc Single Phase. Heating and Cooling - MDC
WH-MDC05F3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
5,00
1,82
2,75
5,00
1,95
2,56
5,00
-15
4,50
1,44
3,13
4,50
1,51
2,98
4,50
-7
4,80
1,22
3,93
4,80
1,28
3,75
4,65
2
5,00
0,91
5,49
5,00
0,98
5,10
5,00
7
5,00
0,67
7,46
5,00
0,71
7,04
5,00
25
WH-MDC06G3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
6,15
2,50
2,46
5,90
2,66
2,22
5,65
-15
5,18
1,68
3,08
5,15
1,92
2,68
5,13
-7
5,00
1,23
4,07
5,00
1,45
3,45
5,00
2
6,00
1,13
5,31
6,00
1,35
4,44
6,00
7
7,30
0,78
9,36
7,10
0,93
7,63
6,90
25
WH-MDC09G3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
7,90
3,62
2,19
7,60
3,77
2,02
7,30
-15
7,80
3,38
2,31
7,70
3,63
2,12
7,60
-7
7,00
2,01
3,48
7,45
2,37
3,14
7,00
2
9,00
1,87
4,81
9,00
2,17
4,16
9,00
7
9,00
0,99
9,09
9,00
1,31
6,87
9,00
25
WH-MDC12G6E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
9,30
3,46
2,69
8,90
3,62
2,46
8,50
-15
10,40
3,37
3,09
10,00
3,66
2,73
9,60
-7
11,80
3,10
3,81
11,40
3,31
3,44
11,00
2
12,00
2,10
5,71
12,00
2,53
4,74
12,00
7
12,00
1,38
8,70
12,00
1,66
7,23
11,80
25
WH-MDC16G6E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
10,60
4,09
2,59
10,30
4,38
2,35
10,00
-15
11,90
4,03
2,95
11,40
4,43
2,57
10,80
-7
13,50
3,74
3,61
13,00
3,96
3,28
12,40
2
16,00
3,21
4,98
16,00
3,74
4,28
16,00
7
16,00
2,31
6,93
16,00
2,69
5,95
16,00
25
IP
40
2,20
1,64
1,40
1,13
0,78
COP
40
2,27
2,74
3,32
4,42
6,41
HC
45
5,00
4,50
4,50
5,00
5,00
IP
45
2,45
1,78
1,52
1,26
0,86
COP
45
2,04
2,53
2,96
3,97
5,81
HC
50
5,00
4,40
4,25
5,00
5,00
IP
50
1,68
1,94
1,62
1,44
0,98
COP
50
2,99
2,27
2,62
3,47
5,10
HC
55
5,00
4,30
4,00
5,00
5,00
IP
55
2,90
2,10
1,72
1,63
1,10
COP
55
1,72
2,05
2,33
3,07
4,55
IP
40
2,82
2,17
1,68
1,58
1,09
COP
40
2,00
2,36
2,98
3,80
6,33
HC
45
5,40
5,10
5,00
6,00
6,70
IP
45
2,98
2,41
1,90
1,80
1,24
COP
45
1,81
2,12
2,63
3,33
5,40
HC
50
5,20
5,45
5,00
6,00
6,50
IP
50
3,15
2,81
2,19
2,09
1,41
COP
50
1,65
1,94
2,28
2,87
4,61
HC
55
5,00
5,80
5,00
6,00
6,30
IP
55
3,32
3,20
2,48
2,38
1,58
COP
55
1,51
1,81
2,02
2,52
3,99
IP
40
3,93
3,88
2,60
2,48
1,63
COP
40
1,86
1,96
2,69
3,63
5,52
HC
45
7,00
7,50
7,00
9,00
9,00
IP
45
4,08
4,13
2,89
2,78
1,95
COP
45
1,72
1,82
2,42
3,24
4,62
HC
50
6,45
7,55
7,00
8,95
9,00
IP
50
4,06
4,59
3,37
3,31
2,20
COP
50
1,59
1,64
2,08
2,70
4,09
HC
55
5,90
7,60
7,00
8,90
9,00
IP
55
4,03
5,05
3,85
3,84
2,45
COP
55
1,46
1,50
1,82
2,32
3,67
IP
40
3,79
3,95
3,53
2,96
1,94
COP
40
2,24
2,43
3,12
4,05
6,08
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,95
4,24
3,74
3,39
2,23
COP
45
2,05
2,17
2,83
3,54
5,25
HC
50
—
—
—
—
—
IP
50
—
—
—
—
—
COP
50
—
—
—
—
—
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,10
4,21
4,08
4,10
2,74
COP
55
1,71
1,95
2,23
2,93
4,16
IP
40
4,67
4,83
4,18
4,27
3,07
COP
40
2,14
2,24
2,97
3,75
5,21
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
4,96
5,22
4,40
4,80
3,45
COP
45
1,96
1,97
2,70
3,33
4,64
HC
50
—
—
—
—
—
IP
50
—
—
—
—
—
COP
50
—
—
—
—
—
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,84
4,88
4,44
5,33
3,89
COP
55
1,63
1,84
2,21
2,72
4,09
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
70
NEW / AQUAREA
Cooling capacity table
Aquarea G Generation High Performance Mono‑bloc Single Phase. Heating and Cooling - MDC
WH-MDC05F3E5
Tamb
CC
IP
EER
LWC
7
7
7
1,95
0,45
4,33
18
5,00
1,25
4,00
25
4,50
1,35
3,33
35
3,75
1,75
2,14
43
WH-MDC06G3E5
Tamb
CC
IP
EER
LWC
7
7
7
4,64
0,91
5,10
18
5,85
1,43
4,09
25
5,50
2,03
2,71
35
4,56
2,34
1,95
43
WH-MDC09G3E5
Tamb
CC
IP
EER
LWC
7
7
7
5,36
1,05
5,10
18
6,44
1,85
3,48
25
7,00
2,90
2,41
35
5,32
3,18
1,67
43
WH-MDC12G6E5
Tamb
CC
IP
EER
LWC
7
7
7
7,86
1,18
6,66
18
12,08
2,90
4,17
25
10,00
3,56
2,81
35
7,80
3,80
2,05
43
WH-MDC16G6E5
Tamb
CC
IP
EER
LWC
7
7
7
9,20
1,62
5,68
18
14,40
3,92
3,67
25
12,20
4,76
2,56
35
7,75
3,40
2,28
43
CC
14
2,20
6,30
5,10
4,50
IP
14
0,45
1,20
1,50
1,80
EER
14
4,89
5,25
3,40
2,50
CC
18
2,45
6,30
5,00
4,25
IP
18
0,50
0,80
1,00
1,20
EER
18
4,90
7,88
5,00
3,54
CC
14
5,83
9,55
6,70
6,31
IP
14
0,99
1,73
2,06
2,47
EER
14
5,89
5,52
3,25
2,55
CC
18
6,74
9,81
7,30
7,14
IP
18
0,94
1,68
2,05
2,45
EER
18
7,17
5,84
3,56
2,91
CC
14
6,12
10,50
8,40
6,34
IP
14
1,08
2,51
2,95
2,48
EER
14
5,67
4,18
2,85
2,56
CC
18
7,02
11,16
9,00
6,78
IP
18
1,08
2,52
3,00
2,46
EER
18
6,50
4,43
3,00
2,76
CC
14
13,15
15,70
12,00
11,10
IP
14
2,05
3,05
3,67
3,19
EER
14
6,41
5,15
3,27
3,48
CC
18
10,00
10,00
10,00
8,00
IP
18
1,73
1,97
2,15
2,85
EER
18
5,78
5,08
4,65
2,81
CC
14
16,40
19,20
15,00
13,80
IP
14
2,58
3,83
4,98
5,95
EER
14
6,36
5,01
3,01
2,32
CC
18
12,20
12,20
12,20
9,70
IP
18
2,45
2,79
2,96
4,00
EER
18
4,98
4,37
4,12
2,43
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
71
HEATING & COOLING
CAPACITY TABLES
Based on outlet temperature and outside temperature.
Heating capacity table
Aquarea G Generation T‑CAP Mono‑bloc Single Phase / Three Phase. Heating and Cooling - MXC
WH-MXC09G3E5 / WH-MXC09G3E8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
9,00
3,24
2,78
9,00
3,51
2,56
9,00
-15
9,00
2,71
3,32
9,00
3,16
2,85
9,00
-7
9,00
2,36
3,81
9,00
2,51
3,59
9,00
2
9,00
1,64
5,49
9,00
1,86
4,84
9,00
7
13,60
1,50
9,07
13,60
1,71
7,95
13,20
25
WH-MXC12G6E5 / WH-MXC12G9E8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
12,00
4,75
2,53
12,00
4,96
2,42
12,00
-15
12,00
3,85
3,12
12,00
4,41
2,72
12,00
-7
12,00
3,19
3,76
12,00
3,49
3,44
12,00
2
12,00
2,18
5,50
12,00
2,53
4,74
12,00
7
13,60
1,55
8,77
13,60
1,76
7,73
13,40
25
WH-MXC16G9E8
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
16,00
6,30
2,54
16,00
6,89
2,32
16,00
-15
16,00
5,85
2,74
16,00
6,42
2,49
16,00
-7
16,00
4,67
3,43
16,00
5,21
3,07
16,00
2
16,00
3,35
4,78
16,00
3,74
4,28
16,00
7
16,00
2,02
7,92
16,00
2,58
6,20
16,00
25
IP
40
3,91
3,62
2,78
2,16
1,93
COP
40
2,30
2,49
3,24
4,17
6,84
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,30
4,07
3,05
2,46
2,14
COP
45
2,09
2,21
2,95
3,66
5,98
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,73
4,27
3,56
2,76
2,41
COP
50
1,90
2,11
2,53
3,26
4,98
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,16
4,46
4,07
3,06
2,67
COP
55
1,74
2,02
2,21
2,94
4,19
IP
40
5,41
4,98
3,87
2,96
2,10
COP
40
2,22
2,41
3,10
4,05
6,38
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,38
5,54
4,25
3,39
2,43
COP
45
2,04
2,17
2,82
3,54
5,43
HC
50
10,80
12,00
12,00
12,00
12,60
IP
50
5,82
5,90
4,86
3,78
2,66
COP
50
1,86
2,03
2,47
3,17
4,74
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,26
6,26
5,47
4,16
2,89
COP
55
1,68
1,92
2,19
2,88
4,15
IP
40
7,45
7,00
5,74
4,30
2,91
COP
40
2,15
2,29
2,79
3,72
5,49
HC
45
16,00
16,00
16,00
16,00
16,00
IP
45
8,10
7,57
6,31
4,80
3,36
COP
45
1,98
2,11
2,54
3,33
4,76
HC
50
16,00
16,00
16,00
16,00
16,00
IP
50
8,48
8,10
6,90
5,43
3,74
COP
50
1,89
1,98
2,32
2,95
4,28
HC
55
15,20
16,00
16,00
16,00
16,00
IP
55
8,96
8,62
7,50
5,91
4,00
COP
55
1,70
1,86
2,13
2,71
4,00
Cooling capacity table
Aquarea G Generation T‑CAP Mono‑bloc Single Phase / Three Phase. Heating and Cooling - MXC
WH-MXC09G3E5 / WH-MXC09G3E8
Tamb
CC
IP
EER
LWC
7
7
7
7,00
1,36
5,15
18
7,65
1,91
4,01
25
7,00
2,21
3,17
35
6,25
2,66
2,35
43
WH-MXC12G6E5 / WH-MXC12G9E8
Tamb
CC
IP
EER
LWC
7
7
7
10,00
1,75
5,71
18
11,20
2,67
4,19
25
10,00
3,56
2,81
35
8,00
3,35
2,39
43
WH-MXC16G9E8
Tamb
CC
IP
EER
LWC
7
7
7
8,50
1,70
5,00
18
14,00
4,00
3,50
25
12,20
4,76
2,56
35
7,10
3,31
2,15
43
CC
14
8,55
11,10
9,23
8,55
IP
14
1,41
1,98
2,37
2,71
EER
14
6,06
5,61
3,89
3,15
CC
18
7,00
7,00
7,00
5,60
IP
18
1,00
1,10
1,35
1,60
EER
18
7,00
6,36
5,19
3,50
CC
14
13,20
16,50
12,55
10,00
IP
14
1,96
3,01
3,63
3,46
EER
14
6,73
5,48
3,46
2,89
CC
18
10,00
10,00
10,00
8,00
IP
18
1,40
1,60
1,95
2,30
EER
18
7,14
6,25
5,13
3,48
CC
14
—
—
—
—
IP
14
—
—
—
—
EER
14
—
—
—
—
CC
18
10,00
14,00
12,20
9,80
IP
18
1,70
2,94
3,50
3,31
EER
18
5,88
4,76
3,49
2,96
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
72
NEW / AQUAREA
Heating capacity table
Aquarea G Generation HT Mono‑bloc Single Phase / Three Phase. Heating Only - MHF
WH-MHF09G3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
9,00
3,46
2,60
9,00
3,71
2,43
9,00
-15
9,00
3,06
2,94
9,00
3,29
2,74
9,00
-7
9,00
2,43
3,70
9,00
2,61
3,45
9,00
2
9,00
1,82
4,95
9,00
1,94
4,64
9,00
7
9,00
1,52
5,92
9,00
1,70
5,29
9,00
25
WH-MHF12G6E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
12,00
5,16
2,33
12,00
5,53
2,17
11,00
-15
12,00
4,43
2,71
12,00
4,76
2,52
11,50
-7
12,00
3,42
3,51
12,00
3,68
3,26
11,50
2
12,00
2,52
4,76
12,00
2,69
4,46
12,00
7
12,00
2,03
5,91
12,00
2,36
5,08
12,00
25
IP
40
4,01
3,56
2,91
2,21
1,88
COP
40
2,24
2,53
3,09
4,07
4,79
HC
45
8,80
8,90
9,00
9,00
9,00
IP
45
4,26
3,83
3,21
2,46
2,16
COP
45
2,07
2,32
2,80
3,66
4,17
HC
50
8,50
8,90
9,00
9,00
9,00
IP
50
4,71
4,28
3,72
2,99
2,63
COP
50
1,80
2,08
2,42
3,01
3,42
HC
55
7,80
9,00
9,00
9,00
9,00
IP
55
5,38
5,02
4,37
3,64
3,20
COP
55
1,45
1,79
2,06
2,47
2,81
IP
40
5,51
4,91
3,86
3,06
2,69
COP
40
2,00
2,34
2,98
3,92
4,46
HC
45
10,80
11,20
11,30
12,00
12,00
IP
45
5,49
5,06
4,14
3,44
3,02
COP
45
1,97
2,21
2,73
3,49
3,97
HC
50
9,70
10,10
10,80
12,00
12,00
IP
50
5,52
5,06
4,66
4,10
3,61
COP
50
1,76
2,00
2,32
2,93
3,32
HC
55
8,00
9,60
10,30
12,00
12,00
IP
55
5,61
5,43
5,13
4,97
4,37
COP
55
1,43
1,77
2,01
2,41
2,75
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
73
EXAMPLES OF INSTALLATIONS
Aquarea H Generation: Bivalent with buffer tank and mixing valve.
Aquarea H Generation: Buffer tank with solar and mixing valve.
Aquarea H Generation: 2 zones with external kit without buffer tank.
Aquarea H Generation: 2 zones with external kit, buffer tank and swimming pool.
Aquarea All in One H Generation: 2 zones with external kit, without buffer tank.
Aquarea All in One 2 zones H Generation: 2 zones built-in, without buffer tank.
74
NEW / AQUAREA
DIMENSIONS
All in One H Generation
Front view
Side view
Top view
717
1.800
598
Bottom View
478
60
36
612
70
60
Unit: mm
All in One G Generation
Side view
717
Top view
295
319
Front view
1.800
Bottom View
60
60
598
156
427
29
36
562
612
1.329
70
478
Unit: mm
75
DIMENSIONS
Hydraulic Module H Generation
Side View
Front View
Bottom View
Top View
424,5
500
51,5
340
339,3
56,1
45
404,1
54,6
180
980
892
360
69,5
More than 375
5
Wall
437,3
476
More than 375
5
Wall
156
Indoor
Unit body
756
88,3
49
30,6
129,5
≥1.556 from ground
250
Installation
plate
58,9
141,9
326,9
Bolt size M8
100
Installation plate
Unit: mm
Hydraulic Module F Generation
Front View
Bottom View
496
116
97,5
Relative position between the indoor unit
and the installation plate Front View
502
490
963
5,6
4,0
52,5
41,4
140,7
364
3-Ø15-hole
213,5
63
2,6
110
74,9
213,5
63
484
892
120
97,5
241
228,5
360
353
38
Top View
271
205,5
98,5
17
Side View
140,7
157
57
171
306,4
31
35
98
115
107
Indoor unit external
dimensions line
70
97
20
28
Installation plate
155
6
76
6
Unit: mm
NEW / AQUAREA
Bi‑bloc outdoor unit 3 and 5kW
Top View
Space necessary for installation
21,9
823,4
540
160
68,5
53,4
32
(124)
167
97
10cm
10cm
330
100cm
Anchor bolt pitch 355 x 260
Side View
37
298
Front View
69
(23)
61
622
Side View
Unit: mm
Bi‑bloc outdoor unit 7 and 9kW
391
20
40
355
320
400
(15)
Top View
Side View
Front View
Side View
900
110
(30)
Back View
DD
24
176
410
795
(30)
(10)
(10)
318,5
320
(140)
620
300
175
140
Unit: mm
77
DIMENSIONS
Bi‑bloc outdoor unit from 9 to 16kW
Side View
40
Front View
900
620
(140)
320
140
(20)
40
320
355
400
Side View
Top View
1340
Space necessary for installation
10cm
10cm
100cm
Anchor bolt pitch 355 x 260
Unit: mm
Mono‑bloc outdoor unit from 5 to 9kW
Top View
(579)
320
355
400
(10)
152
Side View
980
Front View
1.283
152
Side View
(20)
70
480
865
(10)
(10)
319
Unit: mm
78
NEW / AQUAREA
Bi‑bloc Super Quiet outdoor unit and Mono‑bloc outdoor unit from 9 to 16kW
Top View
320
356
400
(579)
152
Side View
Front View
Side View
1.283
Back View
(30)
c
70
275
175
413
426,5
45 45 45
1.410
615
30
318,5
50
83,5
Aquarea DHW Floor standing
Aquarea DHW Wall mounted
Air inlet
589
170
Air inlet
190
Air outlet
285
157
ø160
Air outlet
Unit: mm
324
Hot water outlet
Inlet PT
A
I
264
350
21
294
Outlet
PT
144
C
Cold water inlet
D
670
690
170
Air inlet
ø160
ø160
120
Air outlet
533
A
B
C
F
H
I
PAW-DHWM200A PAW-DHWM300A PAW-DHWM300AE
1.170
1.560
1.560
580
690
690
/
/
1.020
975
1.375
1.375
1.540
1.930
1.930
615
840
840
506
251
B
C
F
J2 Sensor pipe
J1 Sensor pipe
Circulation
pipeline
B
H
A
350
A
B
C
D
PAW-DHWM80ZNT 1.197 345 100 100
PAW-DHWM100ZNT 1.342 490 100 100
PAW-DHWM120ZNT 1.497 645 100 100
Unit: mm
79
Notes
80
NEW / AQUAREA
81
82
NEW / AQUAREA
www.aircon.panasonic.eu
83
www.eggeassociats.net
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without
prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic Marketing Europe GmbH.
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the
damage and deterioration in safety due to usage of the other refrigerant.
The outdoor units in this catalogue contains fluorinated greenhouse gases with a GWP higher than 150.
To find out how Panasonic cares for you,
log on to: www.aircon.panasonic.eu
Panasonic Marketing Europe GmbH
Panasonic Air Conditioning
Hagenauer Strasse 43, 65203 Wiesbaden, Germany
Download PDF