Environment/Water - Food/Beverage - Petrochemistry - Chemical/Plating
Pharmaceutical/Cosmetics/Biotechnology
Titration
customised to
YOUR
exact application
- when you need to be sure...
The TitraLab®
Concept
Why do we use titration?
It can be essential to know the exact concentration of a
chemical species or molecule in raw materials or products
in order to ensure the efficiency of a manufacturing process
and the quality of the finished goods. Among the many
techniques available, titration is commonly selected because
of its ease of implementation, cost-effectiveness and
accuracy. As it is well suited to a wide range of applications
and concentrations, it has been adopted as a standard
technique in a variety of industries such as water quality,
pharmaceuticals, petrochemicals and food and beverage.
Whatever the application, productivity and traceability are
of paramount importance. Automation of routine titration
increases analysis throughput and secures the consistent
quality of results and integrated documentation functions
ensure compliance with Good Laboratory Practice.
2
Radiometer Analytical’s TitraLab range is designed to satisfy
this demand with systems ranging from simple routine titrators
for basic applications to high-performance customised
set-ups with sample changers and dedicated software.
Contents
The TitraLab Concept
2
A Workstation for Every Application
4
Potentiometric Titration Workstations
- Ready for immediate analysis
- A new user interface
- Technical specifications
6
8
10
Karl Fischer Titration Workstation
12
Dedicated PC Software
14
Sample Changers
16
Burette Extension
21
Accessories
22
This catalogue gives an
overview of how TitraLab
can meet your titration
requirements.
Detailed individual
brochures are available
for each instrument.
To see what TitraLab
provides for your
particular application,
visit us at
www.titration.com
What is TitraLab?
TitraLab is a complete solution providing all
the elements required to build workstations
customised to individual applications: Titration
Managers, sample changers, software, electrodes, solutions and accessories.
Accuracy, traceability, reliability and ease of
use are all key features of our instruments.
Clear-text menus simplify programming and
large displays with real-time curve plotting
allow you to check everything is running
smoothly at a glance. Alphanumeric entries
and detailed printouts make it easy to follow
Good Laboratory Practice.
The TitraLab concept goes beyond the instruments themselves. We have put our 70 years‘
experience in electrochemistry to good use.
TitraLab includes dedicated packages for your
application ready to use straightaway: instrument, electrodes, specific accessories, pH calibration and maintenance solutions and, of
course, methods and application notes. The
only thing you have to supply is the sample!
At Radiometer Analytical,
we put applications first.
TitraLab Resource Centre
TitraLab customers enjoy all-round
support from our world-wide network
of distributors. This includes advice on
the right product for your application,
assistance in installation and training
and comprehensive metrology services.
As a TitraLab user, you can take
advantage of our on-line Resource
Centre. You will find useful literature on
theoretical and practical topics and the
latest applications developed by
our TitraLab applications laboratory. In addition, you can be sure
you have access to the most recent
version of your embedded software
by downloading the regular updates
available.
www.titration.com
3
A Workstation for
Every Application
- Dedicated packages
• pH + acidity + free and total SO2 in wine
• pH + acidity + chloride in condiments
• pH + acidity + formol index in fruit juice and soda
• pH and alkalinity in water
• Acid/base determinations in plating baths
• Redox determinations in plating baths
• Peroxide number in edible fats and oils
• Chloride in milk, butter and other dairy products
• Ascorbic acid determination in food and beverages
• Water hardness, calcium and magnesium determination
• T AN and TBN, bromine number and bromine index according to ASTM
• Mercaptans according to ASTM
•M
oisture in cosmetics, chemical, food, pharmaceutical and
petroleum products
4
- Technique-based packages
• Conventional acid/base titration for equivalence point of pH <9
• High-alkalinity acid/base titration for equivalence point of pH >9
• Argentimetric titration (halides and silver)
• Redox titration (zero and imposed current)
• Acid/base titration in non-aqueous media
• Complexometric titration
• pH-Stat titration for standard volumes from 8 to 100 ml
• pH-Stat titration for micro volumes from 0.5 to 9 ml
• Volumetric Karl Fischer titration
- Choose the right workstation for your application
Branch of Activity
Typical Applications
Environment/Water
pH/mV, Alkalinity
Ideal TitraLab workstation
840
+ Hardness, Calcium/Magnesium, Chloride 865
+ Conductivity, Fluoride
870
Food/Beverage
pH/mV, Chloride, Aqueous acid/base titration, Free & total SO2, Formol index
Moisture determination
Pharmaceutical/
Cosmetics/
Biotechnology
pH/mV, Complexometric titrations, pH/mV-Stat
854/856
Moisture determination
580/585/980
Petrochemical
mV, TAN, TBN, Sulphur and 840/845/960/965/980
Mercaptans, Bromine/iodine index
Moisture determination
580/585/980
Chemical/Plating
pH/mV, Acid/base titration, Redox
840/845/960/965
Moisture determination
580/585
840/845
580/585
Redox titration, Aqueous and 960/965/980
non-aqueous acid/base titration
5
- Choose the right workstation for your technique
Workstations: TitraLab 580
Monoburette
585
840
Biburette
845
854
856
865
870
pH/mV End Point determinations
pH/mV Inflection Point determinations
Volumetric Karl Fischer 965
Detachable stand
pH/mV Stat titration
960
Conductivity measurements
ISE measurements 980
Potentiometric
Titration Workstations
- Ready for immediate analysis!
No more wasting time setting up. Order your TitraLab system incorporating a highperformance single or biburette Titration Manager with the appropriate application
package and it will arrive with all you need. Getting started couldn’t be simpler:
Communicate intelligently
Wireless burette stand communication simplifies GLP compliance
The lastest additions to the TitraLab range communicate with their detachable burette stands via wireless
RFID technology. Stand changeover is fast and reliable thanks to instant data recognition which ensures
you use the right reagent with the right data every time.
Save time and energy
Intelligent
design ensures effortless setup and maintenance
Electrodes and tubing slot securely in place in one easy movement thanks to our unique bayonet concept.
For convenient installation and maintenance, the mono-block titrating burette is mounted in no time.
Follow simple instructions
6
Intuitive interface guides you at every step
The Titration Managers prompt you with clear-text messages in a choice of languages, making it so
much easier when you’re doing routine work.
See key data at a glance
A large graphic display gives an instant view of results and analysis status
The titration curve is easy to follow live on the large graphic display together with important data such
as the flow rate, time and dispensed volume. All parameters are displayed in clear text and results can
be seen at a glance. Electrode and titrant status are visualised using easily recognisable icons.
Get measurements right first time
Versatile programming and a high-resolution burette ensure speed and accuracy
Radiometer Analytical’s Titration Managers provide you with flexibility to adapt your methods to
your needs. Automatic sequencing and repetition of measurements are ideal for programming a
direct measurement followed by a titration on the same sample or including a calibration in a series
of analyses. For greater control, QC intervals can be defined. The titrating burettes offer the highest
resolution on the market giving unbeatable accuracy for your potentiometric titrations.
Stay in control
Assistant function and extensive data storage give complete confidence in your results
You can ensure your analysis stays on track thanks to an embedded assistant mode which guides you
through operations such as calibration or reagent installation as well as graphic icons that indicate
calibration status. An extensive non-volatile memory saves your current application methods and lets
you check the last results obtained. When you select a method from the library, the required electrode
and reagents are displayed so there is no risk of error.
Think of tomorrow
Customisable design meets your future needs
All interfaces are standard so you can adapt your system as and when you wish with a sample
changer, standard PC keyboard and/or bar code reader or a PC with TitraMaster 85 Software. You
can add up to 4 burette motors and 4 electrode inputs by connecting two ABUxx Biburettes.
pH
mV
°C
EP
Stat
pH
mV
°C
EP
IP
TitraLab 854/856
TitraLab 840/845
Stat
Titration Workstations
Routine
Titration Workstations
pH
mV
°C
EP
IP
EC
ISE
pH
mV
°C
EP
IP
7
TitraLab 865
TitraLab 870
Combined Conductivity
and Potentiometric
Titration Workstation
Potentiometric
Titration Workstation
pH
mV
°C
EP
IP
KF
pH
mV
°C
EP
IP
TitraLab 960/965
Potentiometric
Titration Workstations
(detachable stands)
TitraLab 980
Volumetric KF
and Potentiometric
Titration Workstation
(detachable stands)
Potentiometric
Titration Workstations
- A new user interface…
The Titration Manager interface has been designed to prompt you
through every step of programming and running an analysis. You will
find that operating your titration unit has never been simpler:
8
n
n
n
n
n
Alphanumeric keypad allows entry of data and parameters.
Large graphic display gives detailed overview of each function.
Animated icons show information on titration status.
Keypad numbers provide shortcuts to functions.
Active on-line help guides operator in setting up the system.
…to guide you every step of the way
1
Select your method.
A058P05A PG
TIMTIM850
850 A
058P0
5A PG
31/10/2
000
2
Enter sample ID and
quantity.
31/10/2000
9
TIM850 A058P05A PG 31/10/2000
3
Prepare your sample.
4
Keep an eye on
the titration in
progress.
5
Archive your result.
6
End or repeat your
analysis.
Potentiometric
Titration Workstations
- Technical specifications
TitraLab 840
845
854
856
865
870
960
965
980
Techniques
pH/mV measurements
End Point titration
Inflection Point titration
pH-Stat titration
Volumetric Karl Fischer Conductivity measurements ISE measurements Titrant addition techniques
Continuous dynamic
Incremental monotonic & dynamic
Burette
Detachable burettes
1
2
1
2
Number of titrating burettes
10
Burette volumes (ml)
Additional titrating burettes Extension/Module
2
2
1
2
2
1 , 5 , 10 , 25 , 50
Up to 4 with 2 x ABU52
Sample changer
Balance
Printer
PC software
Peristaltic pump/TTL connections
PC keyboard and bar code reader
Built-in pump for solvent handling
Up to 4 with 2 x ABU62
Electrode inputs
Indicator electrode
Reference electrode
1
2
1
Polarised electrode
1
Selectable polarised input
±1 mA in 1 µA steps, DC or AC
Additional electrode inputs
Differential measurement
Up to 4 indicator, 2 polarised and 2 reference with 2 ABU52 /2 ABU62
Types of titration
Direct titration
Back titration
Blank determination
Titrant standardisation
pH electrode calibration
Up to 5 points
Method sequencing
Method coupling per sample
Up to 3 methods
2
Up to 10 methods in a series
8
4
6
8
8
TitraLab 840
845
854
856
865
870
960
965
980
Sample list
Number of samples
QC sample definition
Up to 20 samples
Series up to 126 samples with alphanumeric ID
Measuring ranges/Resolution
pH
-9 to 23 pH/0.001 pH
mV
±2000 mV/0.1 mV
°C
-10°C to +100°C/0.1°C
Water content 0.1%
to 100%
Conductivity 4 µS to
400 mS/cm
Results
Auto calculation
User-defined equations
QC check with visual warning
Statistical calculations
On selected result units
2 with user-defined result units
1
Automatic GLP printout
3 levels of detail
Storage capacity
Pre-programmed methods
Global password protection
Non-volatile memory
User-programmable methods
10
50 including pre-programmed methods
Electrode library 15
30 including pre-programmed electrodes
Reagent library
15
Pre-identified electrodes
Pre-identified titrants
Results storage
30 including pre-programmed reagents
A catalogue of up to 30 electrode names and characteristics
A catalogue of up to 20 reagent names
60
Up to 200 sample results, 100 electrode + 100 reagent calibrations
Electrode stand/Stirring
Magnetic stirrer
Propeller stirrer connection
Beaker volume
5 to 400 ml
General specifications
Casing
Splashproof lathene
Keypad
Alphanumeric silicone
Display
Graphic 128x128 dot LCD
Languages
English, French, German, Danish, Spanish, Italian, Swedish
Dimensions (H x W x D)
380 x 230 x 450 mm
Weight (excl. reagent bottles)
5 kg
Power requirements
47.5-63 Hz; 115/230 Vac +15 -18%
11
Karl Fischer
Titration Workstation
- Routine moisture determination…
The determination of water content is essential in many industries in order to
optimise processes and product shelf life. The TitraLab 580 monoburette and
TitraLab 585 biburette Karl Fischer Titration Workstations provide all you need
for fast and reliable moisture determination in both solids
or liquids, whatever your application.
Enjoy full confidence in your results
The titrating burettes on the TitraLab 580/585 offer unbeatable
accuracy for your Karl Fischer titrations. Innovative use of PID
regulation loop algorithms and dynamic continuous titration
addition allow you to end titrations extremely quickly with no
risk of overshooting.
Save bench space
The burette, pump, titration stand and keyboard are all integrated
in one compact unit about the size of your laboratory notebook.
Ensure safety and convenience
12
An electronically driven pump handles KF reagents. During
operation, direct contact with solvents is totally avoided as the
system controls cell filling and waste removal. An embedded
assistant function guides the operator through calibration
or reagent installation and instantly recognisable graphic
icons indicate status.
Rely on maximum tightness
The Karl Fischer cell is easy to set up with electrodes and
tubing slotting quickly and securely in place. It is specially
designed to keep all atmospheric moisture out and simplify sample injection.
Increase analysis throughput
Preset routines guide the operator, facilitating entry of sample
quantity and alphanumeric ID. Automatic detection of sample
injection together with automatic drift determination and compensation with shortcuts result in speed and efficiency. Moreover, automatic cell conditioning reduces downtime while continuous and intelligent cell
volume monitoring prevents overflowing.
Exploit your results to the full
TitraMaster 85 PC Software allows you to program and run methods on the TIM580
and 585 directly from your PC. Its multitasking function makes it easy to follow
analyses,check results and compile reports while analyses are in progress.
…better than ever before
13
Titration methods
Storage capacity/GLP
Burette
Dimensions (H x W x D)
Weight
Power requirements
Specifications
Volumetric KF titration
Karl Fischer cell
KF reagent standardisation
Blank determination
50 methods including 6
preprogrammed applications with
alphanumeric ID and protection Pneumatic circuit
200 results
Inputs/Outputs
10 blank determinations
Encapsulated glass syringe
UV protection
Titrant exchange procedures
380 x 230 x 450 mm (excluding tubing)
Printouts
5 kg (excluding bottles)
Languages
47.5 - 63 Hz, 115/230 Vac +15 -18%
Minimum volume: 35 ml ±5 ml
Maximum volume: 150 ml ±5 ml
Screw type glass beaker, clear or
brown, standard or thermostated
Easy-dismount pump module
Solvent addition and cell emptying
One electrode input & connections
for Printer/PC and additional titrator
Balance
PC keyboard and/or bar code reader
Sample changer
Condensed and detailed GLP bulletins
English, French, German, Spanish,
Italian, Danish and Swedish
Dedicated
PC Software
- TitraMaster 85, a user-friendly tool…
andling sample throughput efficiently while keeping data securely stored for future access
H
is an essential requirement for all laboratories. With TitraMaster 85 user-friendly titration software,
you can program applications directly from the computer while processing data from as many as 7
titration workstations or high-performance ion analysers.
Secure your system completely
User logins and operator passwords prevent unauthorised access
In TitraMaster 85 an access level is assigned to each operator together with a strictly
personal login and password. Each hierarchical level gives access to specific rights
and functions to protect against unauthorised use and unintentional changes.
Program your applications conveniently
8
14
Computer environment facilitates creation of applications
Applications can be programmed and managed directly from the TitraMaster 85
database application window on your PC. Each application is fully traceable
with a version number and a complete historical record of changes.
You can reuse an existing application or return to a previous version.
Run your applications instantly
Straightforward interface allows applications
to be set up in no time
Select an application from your database, fill in the sample stack, press
RUN and follow instructions. That’s all there is to it. Automatic prompts
guide you step by step making your analysis simpler and safer.
Check your results at any time
Immediate information on titration curves and results
Curves and records are displayed live with clear result status icons. Data from each
workstation connected can be featured in an individual window to give you an
overview of analyses in progress. While analyses are running, the database can be
searched by user-selectable criteria so you can process the results that matter.
Record all your data securely
Automatic archiving guarantees you never lose data
TitraMaster 85 offers a powerful automatic archiving tool which allows you to
retrieve records fast and efficiently via user-programmed requests. Each record is
stored with a full set of information specifying how, where, when and by whom it
was obtained.
…for secure and efficient data management
Follow your result trends graphically
isual control chart tool makes Quality Control easy
V
For all analysis results defined with acceptation limits - electrode or reagent calibration,
QC sample or sample batch analysis - you can plot a control chart to keep track of
progress. This ensures you obtain a clear view of trends in measuring chain performance
and analytical data.
Exploit your results to the full
Data processing and export functions ensure
you make efficient use of your data
Your results can be recalculated and/or curves reprocessed according to your
requirements with no risk of losing raw data. Data can be exported to LIMS
or Microsoft Office applications in various file formats.
15
Extended FDA 21 CFR Part 11 solution
Radiometer Analytical has developed a special version of TitraMaster 85
Software in order to help your laboratory fulfil its obligations regarding
document submission and legally binding electronic signatures in compliance
with Food and Drug Administration 21 CFR Part 11 requirements.
With the TitraMaster 85 FDA21CFR11 version, you can be sure of:
• Electronic signatures
• User accounts
• System validation
• Audit trail
• Unfalsifiable records
• Data tracking
• Standard-format exporting
• GLP compliance
• Password protection
• Secure backup
• Controlled access
• Application traceability
The audit report of an outside organisation which examined
TitraMaster 85 compliance with FDA 21 CFR Part 11 is available on request.
SAC850 and SAC950
Sample Changers
- Effortless sample handling...
The obvious choice for your laboratory
Radiometer Analytical sample changers are capable of handling
multiple combinations of titrations, direct pH, ion and conductivity measurements fast and efficiently. Connect to a TitraLab
titration workstation or a direct measurement meter with or
without PC software selected from our complete laboratory
product range and your laboratory will virtually run itself!
Compact and Adaptable
The SAC850 and SAC950 are compatible with a wide selection of
removable sample trays, making them remarkably space-efficient. No
special beakers are required; they accept standard glass and disposable
beakers with volumes ranging from 25 to 400 ml.
There is no need to programme the sample changer each time a new type of sample
tray is used as it is instantly identified by a wireless RFID tag containing all relevant
geometrical characteristics. High rotation speed and smooth turntable movements
allow fast and safe navigation between samples.
16
Flexible and Programmable
Sample preparation sequences can be programmed from TitraMaster 85 Titration PC Software with
specific macro commands to fit your requirements. User-defined sample preparation sequences offer
all the benefits of full automation. You can activate the Start/Stop stirring function or the pumps for
a chosen duration, wait or send a TTL command to/from an external device and wait for a specified
temperature to be reached.
Quick and Efficient
The powerful Dynamic Spray Rinse feature and high flow-rate pumps ensure quick and thorough
cleaning with no risk of cross contamination between samples, helping you achieve greater accuracy
and reproducibility, irrespective of the number of samples per cycle. Efficient rinsing is obtained
thanks to repeated vertical movements of the head combined with the mechanical action of the
sprays.
Rinsing liquid is sprayed from all directions over the entire height of the electrodes and tips while the
waste pump empties beakers and evacuates rinse waste. This dynamic rinsing performed directly over
the analysed beaker reduces the total duration of the sample changer cycle multiplying the number
of samples analysed per day.
Safe and Clean
Our unique bayonet concept keeps electrodes and delivery tips securely in place. This ensures reproducible results and allows you to use any combination of electrodes, conductivity cells, temperature
sensors or delivery tubes for your analyses. Tubes and cables can be inserted or removed in no time
and are held in position in a cable carrier for maximum convenience. Reagent addition tubes are
permanently visible for inspection.
The SAC950 includes 3 external beaker positions (2 for dip rinsing/conditioning and 1 for parking) allowing you to exploit the full beaker capacity of the tray and increase the number of samples
analysed per cycle.
...through total automation
SAC950:
Extended model for automation of large sample series
n Multi-radius sample trays for up to 70 samples.
n External parking position.
n External dip rinsing and electrode conditioning on 1 or 2
positions.
- Dynamic rinsing combined with waste disposal performed
inside the current sample beaker, the external park beaker
or one of the 2 external dip rinse beakers.
n Beaker cover module for sample protection prior to analysis (optional).
17
Functions
SAC950
SAC850
Propeller stirrer 0 - 1200 rpm
l
l
Magnetic stirring (single-radius only) 0 - 1000 rpm
l
l
Beaker detection
l
l
Embedded programmable sample preparation sequences
l
l
2 dip rinsing/conditioning + 1 parking positions, external
l
-
2 dip rinsing/conditioning + 1 parking positions, on sample tray
-
l
Unused electrode and tip storage, 4 positions
l
l
Integrated keyboard for manual sample changer control
l
l
Dynamic rinse/waste disposal pumps, 1 module
O
O
Reagent addition peristaltic pump, 1 module
O
O
Beaker cover module (sample protection prior to analysis)
O
l : Standard O : Optional - : Not available
SAC850:
Basic model for automation of small sample series
n Single-radius sample trays for up to 24 samples.
n Parking position on sample tray.
n Dip rinsing/electrode conditioning performed on 1 or 2
dedicated positions on sample tray.
- Dynamic rinsing combined with waste disposal performed
inside current sample beaker.
SAC950 Key Features
4 dedicated park positions save time as you can
switch between the electrodes and addition tips
required for your applications without having
to remove and reinstall them each time.
18
The co
sures t
into pl
The powerful propeller stirrer ensures perfect
homogeneity of all kinds of sample and enhances
result reproducibility.
Sample changer status is visible from a distance thanks to
a coloured LED: analysis cycle in progress (violet), ready
for new analysis cycle (blue), operating error (red).
An embedded keypad ensures
quick and easy manual control of
movements and pump operation.
SAC950
onvenient cable carrier entubes and cables slot easily
lace for faster setup.
An innovative ultrasonic transducer guarantees both
beaker detection in under a second and safer
operation by eliminating any risk of reagent spillages.
19
The beaker cover option avoids
any risk of interaction between
the samples and the environment
prior to analysis.
Reagent addition via the built-in peristaltic
pump minimises sample preparation time,
simplifies the operator’s task and increases
sample throughput.
Automatic beaker emptying after
analysis disposes of waste reagents
and rinsing liquid making the tray
lighter and easier to remove.
SAC850 and SAC950
Technical Specifications
Trays
Sample tray capacity
SAC850
Single-radius Sample tray capacity
SAC950
Multi-radius
Capacity
Ø x H (mm)
Capacity
Ø x H (mm)
24 samples + 1 park
70 + 2 rinse + 1 park
50 ml low form 42 x 60 22-45 ml & 8-25 ml
44 x 70
21 samples + 1 park
42 + 2 rinse + 1 park
100 ml low form
48 x 80
-
-
19 samples + 1 park
36 + 2 rinse + 1 park
-
-
40-100 ml
60 x 80
19 samples + 1 park
36 + 2 rinse + 1 park
150 ml low form
60 x 80
-
-
19 samples + 1 park
36 + 2 rinse + 1 park
-
-
GOSSELIN 180 ml
54x72/102
17 samples + 1 park
30 + 2 rinse + 1 park
250 ml tall form
60 x 120
-
-
14 samples + 1 park
25 + 2 rinse + 1 park
250 ml low form
70 x 95
-
-
14 samples + 1 park
25 + 2 rinse + 1 park
400 ml tall form
70 x 130
-
Glass beakers*
Polypropylene beakers
*Standard glass beakers specified in accordance with DIN 12331 & ISO 3819.
Pump characteristics
Function
Pump type
Flow rate
Accuracy
Dynamic spray rinse
~10%
Membrane
600 ml/min max.
Empty beaker
~10%
20
Reagent addition
Peristaltic
200-400 rpm
2.0 to 236 ml/min max.
~1%
Pump model/Material
Pump head: PP
Membrane: PTFE
Valve: FFPM (Kalrez®)
Tubing: Maprene®
General specifications
Ambient temperature
5 to 40°C
Relative humidity
20 to 80%
Altitude
< 2000 m
Casing materials
PETP – PVC/PE - Fully splashproof chemical resistant – For use in a laboratory environment
Level of pollution
2
Power supply
100 - 240 Vac / 50 - 60 Hz / 76 VA
Transitory over voltage
Level II
Dimensions H x W x D (cm)
70 x 58 x 68
Weight (kg)
27
Required operating area (cm) 60 x 80
Compliance
- CE, R&TTE Directive (99/5/EEC), EMC Directive (2004/108/EEC),
LV Directive (2006/95/EEC)
- cETLus certification, UL 61010A-1 and CAN/CSA C22 2 n°1010.1-92
- FCC part 15 rules
Inputs/outputs
Connector type
Connector description
USB-B (Slave)
PC connection
Sub-D9 RS232C
Connection to titration workstation or direct measurement meter
RJ11
0-5 V TTL input/output commands
RJ11
Beaker cover module
RJ11
Propeller stirrer
Cinch
Temperature input (for use in sample preparation sequence only)
Jack, 3.5 mm
Ultrasonic transducer for beaker detection
Burette Extension
-C
ustomise your system
to every application
The ABU52 and ABU62 Biburettes come complete with all
necessary accessories. Extending your system couldn’t be simpler:
ABU62
Add extra capacity
Each ABU52 or ABU62 gives you two motor-driven burettes, two electrode inputs and one temperature input. Two ABU52s and ABU62s can be connected to a TitraLab workstation, providing up
to six titrating burettes and six high-impedance electrode inputs in a single system, meeting every
application need. Use the ABU52/62 as an extra titration sample stand or for electrode storage and
reconditioning.
Automate your system
The required ABU52/62 burette and installed electrode are selected via methods programmed in the
titration workstation, with the system taking charge of precise titrant or reagent dispensing. The large
screen display gives you information about reagent status at a glance.
Ensure fast and accurate dispensing
Choose from five monoblock burette sizes: 1, 5, 10, 25 and 50 ml, all conforming to the
ISO 8655-3 standard. The full volume can be dispensed in less than 20 seconds, with a resolution
as small as 0.1 µl with the 1 ml burette.
Use as a stand-alone dosing unit
The ABU52 can be operated manually by simply connecting a standard PC keyboard. Just fit the right
electrode and the ABU52 becomes a versatile manual titration unit. mV/pH readings are shown on
the large screen for each titrant increment dispensed along with a live titration curve. Graphic tools
enable you to determine the location of your equivalence point(s) manually in order to calculate the
final result.
Burette specifications according to ISO 8655-3
Burette
stand
Type
Fixed
Detachable
B501
B601
B505
B605
B510
B610
B525
B625
25
B550
B650
50
a
Nominal
volume
ml
< 1
Maximum permissible
systematic errors
± %
± µla
0.6
6
5
0.3
10
0.2
Maximum permissible
random errors
± %b
± µlc
0.1
1
15
0.1
5
20
0.07
7
0.2
50
0.07
17.5
0.2
1 00
0.05
25
Expressed as the deviation of the mean of a tenfold measurement from the nominal volume or from the selected volume
(see ISO 8655-6:—, 8.4).
b
Expressed as the coefficient of variation of a tenfold measurement (see ISO 8655-6:—, 8.5).
c
Expressed as the repeatability standard deviation of a tenfold measurement (see ISO 8655-6:—, 8.5).
21