This CO detector guide has been produced to help Operatives identify the status of an alarm to ensure the correct action is taken when called to a potential CO activation. Relevant information has been extracted from the user manuals to help assist with the identification of the operating mode of CO detectors that you may encounter so you can establish the correct action to take.

If you encounter an alarm that is not included within this guide then you can check the availability of the instructions with the end user. Where an alarm is sounding and you cannot identify the mode then always take the safest course of action by making the situation safe and advising the consumer to have the appliances checked by a Gas Safe registered installer.

All CO detectors manufactured for the UK market have to meet the requirements of BS EN 50291. This standard sets the minimum requirements for the design and manufacturer of CO detector . More recent detectors have enhanced functionality, such as LCD displays that provide a greater level of information to the homeowner.

Placement Of CO detectors

Correct location of the CO detector is an important to ensure the CO detector is operating in an effective zone and helps to eliminate false activations.

The recommendation for the placement of a CO detector is:

 in every room that contains a fuel burning appliance,

 at least 300 mm from any wall (for ceiling mounted alarms)

 at least 150 mm from the ceiling, above the height of any door or window (for wall mounted alarms)

 between 1 and 3 m (measured horizontally) from the potential source of CO

CO Detectors must not be placed in the following:

 in an enclosed space,

 where it can be obstructed,

 directly above a sink,

Page 1 of 51

 next to a door, window, extractor fan, air vent or similar ventilation opening,

 where the temperature may drop below –5 ºC or exceed 40 ºC.

Where a premises has multiple fuel burning appliances in different rooms, the standard recommends that if there are restrictions in placing an alarm in each room that the priority should be given to putting a detector in rooms containing flueless or open-flued appliances.

CO Detectors are designed to sound a continual audible alarm when the following criteria is met:

CO Concentration Without Alarm Before

30 PPM

50 PPM

100 PPM

300 PPM

120 mins

60 mins

10 mins

-

With Alarm Before

-

90 mins

40 mins

3 mins

Where a detector activates when the above criteria is met then the alarm must continue to sound until the CO PPM readings drop below 50 PPM. When the CO reading drops below this threshold then the alarm should stop alerting within 10 minutes. The CO detection functionality on an alarm is still operating even when the detector is indicating low battery.

Many new detectors contain an LCD display, which indicates the highest PPM reading obtained. This value is displayed even when the alarm stops activating, however it is important to note that the display can be reset therefore removing any information on activation.

Dual Mode CO detectors

It is becoming more common to encounter alarms that have a dual mode, typically these are combined with smoke alarms in a single unit. In some cases they may also contain other functions, such as panic alerts for elderly customers.

Even when you encountered a combined unit the CO element of the alarm must operate independently of any other mode and this must comply with the mimum requirements set out in the CO alarm standard.

Page 2 of 51

FireAngel

CO-9B

CO-9D

CO-9X

CO-9X-10

W2-CO-10X

Kidde

5CO

7CO

7DCO

10LLCO

10LLDCO

10SCO

Honeywell

CO Detector Catalogue

Ei Electronics FirstAlert

XC70

XC100

XC100D

Ei208

Ei261ENRC

SCO5

SCO7

GCO1

CO400

SCO500

CO250

CO600

CO605

CO615

PC900V

CO710

BRK

CO4000EN

CO850

NEST

PROTECT

Page 3 of 51

FireAngel

Contact Details

Telephone

Email

Website

08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/

Main Features

Feature

Power LED (

Green

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Alarm LED flashing

Red

once per second

Function

Indicates that the unit is receiving power and is fully operational

Indicates and emergency situation

Used to test/reset/silence the unit

Sound Emitted

Loud audible signal

What This Means

Dangerous levels of CO has been detected

Off

Power LED flashing

Green

once per minute

Single chirp once per minute

Silent

Low battery/Fault/End of Life

Normal Operating Mode

CO-9B

Required Action

Follow Emergency Procedures

Replace batteries. If warning indicators persist despite having new batteries and the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately

None

Page 4 of 51

FireAngel CO-9D

Page 5 of 51

Contact Details

Telephone

Email

Website

08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/

Main Features

Feature

Power LED [ ] (

Green

)

Alarm LED [ ] (

Red

)

Function

Indicates that the unit is receiving power and is fully operational

Indicates an emergency situation

Test/Mode Button Switch between CO/Temperature view and to test/silence the unit

Operating Features – Part 1 of 2

Digital Screen Light Indicator Sound Emitted What This Means

Alarm [ ] LED flashing

Red

once per second

Loud audible signal

Power [ ] LED flashing

Green

once per minute

Power [ ] LED flashing

Green

once per minute

Power [ ] LED flashing

Green

once per minute

Silent

Silent

Single chirp once per minute

Dangerous levels of CO has been detected

Alarm has been silenced during a recent alarm situation – this can be identified from the presence of a PPM reading on the silence alarm symbol [ ] on the display

The peak level symbol[ ] indicates that CO has been detected in your absence

A fault has been detected in the alarms sensor/circuitry settings

Power [ ] LED flashing

Green

once per minute

Single chirp once per minute

Power Pack Low

Power [ ] LED flashing

Green

once per minute

Power [ ] LED flashing

Green

once per minute

Silent

Silent

The spanner icon [ ] indicates that the alarm is in sensor test mode

Temperature Display View

Required Action

Follow Emergency Procedures

If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately

Perform sensor test or end the test by holding down the Test/Mode button until the spanner icon disappears

To switch between CO and temperature view, press the Test/Mode button briefly

Page 6 of 51

Contact Details

FireAngel CO-9X

Page 7 of 51

Telephone

Email

Website

08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/

Main Features

Feature

Power LED (

Green

)

Fault LED (

Yellow

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Alarm LED flashing

Red

once per second

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault

Indicates an emergency situation

Used to test/reset/silence the unit

Sound Emitted

Loud audible signal

What This Means

Dangerous levels of CO has been detected

Fault LED

Yellow

flashing once per minute

Power LED flashing

Green

once per minute

Single chirp once per minute

Silent

Low Battery/Fault

Normal Operating Mode

Required Action

Follow Emergency Procedures

If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately

None

Page 8 of 51

FireAngel

Contact Details

Telephone

Email

Website

08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/

Main Features

Feature

Power LED (

Green

)

Fault LED (

Yellow

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Alarm LED flashing

Red

once per second

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/reset/silence the unit

Sound Emitted

Loud audible signal

What This Means

Dangerous levels of CO has been detected

Fault LED flashing

Yellow

once per minute

Power LED flashing

Green

once per minute

Single chirp once per minute

Silent

Low Battery/Fault/End of life

Normal Operating Mode

CO-9X-10

Required Action

Follow Emergency Procedures

If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately

None

Page 9 of 51

FireAngel

Contact Details

Telephone

Email

Website

+44 (0) 8001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/

Main Features

Feature

Power LED (

Green

)

Fault LED (

Yellow

)

Alarm LED (

Red

)

Test/Silence Button

Operating Features

Light Indicator

Alarm LED flashing

Red

once every 5 seconds

Fault LED flashing

Yellow

once per minute

Fault LED flashing Yellow once per minute

Power LED flashing Green once per minute

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/silence the unit

Sound Emitted

Four chirps repeated

Single chirp once per minute (In sync with fault LED flashes)

Single chirp once per minute (nonconcurrent with fault LED flashes)

Silent

What This Means

Dangerous levels of CO has been detected

Low Battery/End of Life

Sensor Fault

Normal Operating Mode

W2-CO-10X

Required Action

Follow Emergency Procedures

If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately

None

Page 10 of 51

Kidde

Contact Details

Telephone

Email

Website

Main Features

Feature

Operate LED (

Green

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Alarm LED flashing

Red

Alarm LED on (

Red

)

Alarm LED flashing

Red

twice every 30 seconds

Alarm LED flashing

Red

once every 30 seconds

Alarm LED flashing

Red

once per minute

Operate LED flashing

Green

once every 30 seconds

08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates an emergency situation/fault/low batteries/end of life

Used to test/reset/silence the unit

Sound Emitted

Loud continual signal (4 beeps – 5 seconds pause – 4 beeps…)

Constant audible signal

Two chirps every 30 seconds

Single chirp every 30 seconds

Single chirp once per minute

Silent

What This Means

Dangerous levels of CO has been detected

Malfunction

End of life

Fault

Low Battery

Normal Operating Mode

5CO

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace Batteries

None

Page 11 of 51

Kidde

Contact Details

Telephone

Email

Website

Main Features

Feature

Operate LED (

Green

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Alarm LED flashing

Red

Alarm LED on (

Red

)

Alarm LED flashing

Red

twice every 30 seconds

Alarm LED flashing

Red

once every 30 seconds

Alarm LED flashing

Red

once per minute

Operate LED flashing

Green

once every 30 seconds

08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates an emergency situation/fault/low batteries/end of life

Used to test/reset/silence the unit

Sound Emitted

Loud continual signal (4 beeps – 5 seconds pause – 4 beeps…)

Constant audible signal

Two chirps every 30 seconds

Single chirp every 30 seconds

Single chirp once per minute

Silent

What This Means

Dangerous levels of CO has been detected

Malfunction

End of life

Fault

Low Battery

Normal Operating Mode

7CO

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace Batteries

None

Page 12 of 51

Kidde

Contact Details

Telephone

Email

Website

Main Features

Feature

Operate LED (

Green

)

Alarm LED (

Red

)

Test/Reset Button

Peak Level Button

Digital Display

+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates an emergency situation/fault/low batteries/end of life

Used to test/reset/silence the unit

Displays the peak CO reading

Visual display of product’s indicators

Operating Features

Digital Screen Light Indicator

Alarm LED flashing

Red

and

CO level on display

Sound Emitted

Full alarm (4 beeps – pause – 4 beeps)(repeating)

Constant audible signal (not full alarm)

Two chirps once every 30 seconds

What This Means

Dangerous levels of CO has been detected

Malfunction Alarm LED on (

Red

)

Alarm LED flashing

Red

twice every 30 seconds

End of Life

Alarm LED flashing

Red

Single chirp once every 30 seconds

Alarm LED flashing

Red

once per minute

Single chirp once per minute

1 beep, then 2 sets of 4 beeps, followed by 1 beep

Alarm LED flashing

Red

Operate LED flashing

Green

once every 30 seconds

Silent

Fault

Low Battery

Successful test or reset sequence in operation

Normal Operating Mode

7DCO

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace Batteries

None

None

Page 13 of 51

Kidde

Contact Details

Telephone

Email

Website

Main Features

Feature

Operate LED (

Green

)

Fault LED (

Amber

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features – Part 1 of 2

Light Indicator

Alarm LED on (

Red

)

Off

Alarm LED flashing

Red

twice every 30 seconds and fault LED flashing

Amber

once per second

Fault LED flashing

Amber

once every

30 seconds and operate LED (

Green)

blinks error code every other 30 seconds

Fault LED flashing

Amber

once every

30 seconds

Alarm LED flashing

Red

once per minute

Operate LED flashing

Green

once every

30 seconds

+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/reset/silence the unit

Sound Emitted

Loud continuous signal (four loud alarm sounds, repeated for four minutes, followed by two patterns per minute)

Constant signal

Two chirps every 30 seconds

Single beep every 30 seconds

One beep per minute

Silent

Silent

What This Means

Dangerous levels of CO has been detected

Malfunction

End of Life

Fault

Low Battery

Historical event in last 14 days

Normal Operating Mode

Page 14 of 51

10LLCO

Required Action

Follow Emergency Procedures

Replace the Alarm

If cold allow unit to warm up for a couple of hours then replace if still beeping

Follow Emergency Procedures

None

Kidde 10LLDCO

Page 15 of 51

Contact Details

Telephone

Email

Website

Main Features

Feature

Operate LED (

Green

)

Fault LED (

Amber

)

Alarm LED (

Red

)

Test/Reset Button

Peak Level Button

Operating Features

Digital Screen

08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/reset/silence the unit

Displays the peak CO reading

Light Indicator

Alarm LED flashing

Red

Sound Emitted

Continual audible signal

What This Means

Dangerous levels of CO has been detected

Malfunction

Required Action

Follow Emergency

Procedures

Off

Alarm LED flashing

Red

twice every 30 seconds. Fault LED flashing

Amber

once per second

Fault LED flashing

Amber

once per second and operate LED (

Green

) flashing error code every other 30 seconds

Fault LED flashing

Amber

once per second

Alarm LED flashing

Red.

Operate (

Green

) and Fault (

Amber

) LED on

Operate LED flashing

Green

every 30 seconds

Constant signal

Two chirps every 30 seconds

Single chirp every 30 seconds

Single chirp once per minute

1 beep, then 2 sets of 4 beeps, followed by 1 beep

Silent

End of Life

Replace the Alarm

Fault

Low Battery

Successful test or reset sequence in operation

If cold allow unit to warm up for a couple of hours then replace if still beeping

None

Normal Operating Mode None

Page 16 of 51

Contact Details

Telephone

Email

Website

Main Features

Feature

Green

LED

Red

LED

Test/Reset/Hush

Operating Features

Light Indicator

+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk

Function

Indicates that the unit is receiving power

Indicates an emergency situation

Used to test/reset/silence the unit

Red

LED flashes

Red

LED flashes

Off

Red

LED flashes

Red

LED flashes once every minute

Green

LED flashes every 30 seconds

Sound Emitted

Alarm: Four short beeps followed by the verbal message

Verbal: “WARNING! CARBON

MONOXIDE!” After four minutes the alarm/voice will sound once every minute until the unit is reset

Alarm: Three long beeps followed by the verbal message

Verbal: “FIRE! FIRE!”, repeated until the smoke is eliminated

2 chirps every 30 seconds

Single chirp every 30 seconds

Voice: “LOW BATTERY”, this cycle will occur for the first hour. After the first hour the voice message “LOW

BATTERY” will sound once every 15 minutes.

Silent

Honeywell

What This Means

Dangerous levels of CO has been detected

Dangerous levels of Smoke has been detected

End of Life

Malfunction

Low Battery

Normal Operating Mode

XC70

Page 17 of 51

Required Action

Follow Emergency Procedures

Call Emergency Services

Replace the Alarm

Replace the Alarm

Replace Batteries

None

Contact Details

Telephone

Email

Website

Main Features

01202 645 577 [email protected] www.homesafety.honeywell.com

Feature

Power LED (

Green

)

Fault LED (

Yellow

)

Ventilate LED (

Blue

)

Alarm LED (

Red

)

Test/Hush button

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery or fault

Early warning of CO build-up

Indicates an emergency situation

Used to test/silence the unit

Operating Features – Part 1 of 2

Light Indicator

Alarm LED flashing

Red

Sound Emitted

Continuous 4 chirps for 60 minutes then once every 30 seconds

Off

Alarm LED flashing

Red

once per minute

Continuous 4 chirps

Chirp once per minute

Honeywell

What This Means

Dangerous levels of CO has been detected

Dangerous levels of CO has been detected by another interconnected CO alarm

Dangerous levels of CO was detected whilst user was absent.

Currently, no dangerous CO level present

XC70

Operating Features – Part 2 of 2

Light Indicator Sound Emitted What This Means

Page 18 of 51

Check Appliances

Page 2 of 2

Required Action

Required Action

Follow Emergency Procedures

Follow Emergency Procedures

Off

Ventilate LED flashing

Blue

1 (2, or

3) times once every 30 seconds, increasing the longer CO is present

Fault LED flashing

Yellow

3 times per minute

Fault LED flashing

Yellow

once per minute

Power LED flashing

Green

once per minute

Continuous 3 chirps

1 (2, or 3) chirps once every 30 seconds, increasing the longer CO is present

3 chirps per minute

Chirp once per minute

Fire detected by an interconnected fire alarm

A dangerous CO condition is building up.

The wireless module is not working correctly

End of Life

Silent Normal Operating Mode

Follow Emergency Procedures

Check Appliances

Refer to the wireless module manual for further details

Replace the Alarm

None

Page 19 of 51

Honeywell XC100

Page 20 of 51

Contact Details

Telephone

Email

Website

Main Features

Feature

01202 645 577 [email protected] www.homesafety.honeywell.com

Function

Power LED (

Green

)

Fault LED (

Yellow

)

Ventilate LED (

Blue

)

Alarm LED (

Red

)

Test/Hush button

Operating Features – Part 1 of 2

Light Indicator

Alarm LED flashing

Red

Indicates that the unit is receiving power and is fully operational

Indicates low battery or fault

Early warning of CO build-up

Indicates an emergency situation

Used to test/silence the unit

Sound Emitted

Continuous 4 chirps for 60 minutes then once every 30 seconds

What This Means

Dangerous levels of CO has been detected

Off

Alarm LED flashing

Red

once per minute

Continuous 4 chirps

Chirp once per minute

Dangerous levels of CO has been detected by another interconnected CO alarm

Dangerous levels of CO was detected whilst user was absent. Currently, no dangerous CO level present

Fire detected by an interconnected fire alarm Off

Ventilate LED flashing

Blue

1 (2, or 3) times once every 30 seconds, increasing the longer CO is present

Continuous 3 chirps

1 (2, or 3) chirps once every 30 seconds, increasing the longer CO is present

A dangerous CO condition is building up.

Fault LED flashing

Yellow

3 times per minute

3 chirps per minute The wireless module is not working correctly

Fault LED flashing

Yellow

per minute

Power LED flashing

Green

once per minute

Chirp once per minute

Silent

End of Life

Normal Operating Mode

Required Action

Follow Emergency

Procedures

Refer to the wireless module manual for further details

Replace the Alarm

None

Page 21 of 51

Honeywell XC100D

Contact Details

Telephone

Email

08009 170 722 [email protected]

Website

www.TenYCO.kiddefyrne0cs.co.uk

Main Features

Feature Function

Power LED (

Green

)

Fault LED (

Yellow

)

Ventilate LED (

Blue

)

Alarm LED (

Red

)

Test/Hush button

Indicates that the unit is receiving power and is fully operational

Indicates low battery or fault

Early warning of CO build-up

Indicates an emergency situation

Used to test/silence the unit

Visual display of product’s indicators Digital Display

Operating Features – Part 1 of 2

Digital Screen Light Indicator Sound Emitted What This Means

Power LED flashing

Green

Continuous 4 chirps for 60 minutes then once every 30 seconds

Dangerous levels of CO has been detected

Off Continuous 4 chirps

Dangerous levels of CO has been detected by another interconnected CO alarm

Page 1 of 2

Required Action

Follow Emergency Procedures

Page 22 of 51

Honeywell

Digital Screen Light Indicator

Alarm LED flashing

Red

once per minute

Alarm LED flashes

Red

once per minute

XC100D Page 2 of 2

Sound Emitted

Chirp once per minute

Chirp once per minute

Off Continuous 3 chirps

Ventilate LED flashing

Blue

1 (2, or 3) times once every 30 seconds, increasing the longer

CO is present

Fault LED flashing

Yellow

3 times every minute

1 (2, or 3) chirps once every 30 seconds, increasing the longer

CO is present

3 chirps per minute

What This Means

Dangerous levels of CO was detected whilst user was absent.

Currently, no dangerous CO level present

Dangerous levels of CO was detected whilst user was absent.

Currently, no dangerous CO level present

Fire detected by an interconnected fire alarm

Required Action

Follow Emergency Procedures

Contact Emergency Services

A dangerous CO condition is building up.

The wireless module is not working correctly

Follow Emergency Procedures

Refer to the wireless module manual for further details

Fault LED flashing

Yellow

once every minute

Chirp once per minute End of Life Replace the Alarm

Power LED flashing

Green

once every minute

Silent Normal Operating Mode None

Page 23 of 51

EI Electronics Ei208

Contact Details

Telephone

Email

Website

+44 (0) 1691 664 100 [email protected] www.aico.co.uk

Main Features

Feature

Power LED (

Green

)

Fault LED (

Amber

)

Alarm LED (

Red

)

Test & Hush Button

Operating Features

Light Indicator

Alarm LED flashing

Red

1, 2 or 4 times every 2 seconds (the higher the CO concentration the more flashes)

Alarm LED flashing

Red

2, 4 or 8 times every 40 seconds (the higher the CO concentration the more flashes)

Fault LED flashing

Amber

3 times every 40 seconds

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/silence the unit

Sound Emitted

Continual audible signal

Silent

3 Beeps every 40 seconds

What This Means

Dangerous levels of CO has been detected

The detector has alarmed previously (within 24 hours)

End of Life

Page 1 of 2

Required Action

Follow Emergency Procedures

Check appliances and reset detector memory by holding down the Test & Hush button for 20 seconds

Replace the Alarm

Page 24 of 51

EI Electronics

Operating Features – Part 2 of 2

Light Indicator

Fault LED flashing

Amber

twice every 40 seconds

Fault LED flashing

Amber

once every 40 seconds

Power LED on

Green

Sound Emitted

2 Beeps every 40 seconds

1 Beep every 40 seconds

Silent

Ei208

What This Means

Sensor Fault

Low Battery

Normal Operating Mode

Page 2 of 2

Required Action

Replace the Alarm

Replace the Alarm

None

Page 25 of 51

EI Electronics E261ENRC

Contact Details

Telephone

Email

Website

Main Features

Feature

Power LED (

Green

)

Fault LED (

Amber

)

Alarm LED (

Red

)

Test & Hush Button

Operating Features

Light Indicator

Alarm LED flashing

Red

Alarm LED flashing

Red

2, 4 or 8 times every 40 seconds (the higher the CO concentration the more flashes)

Fault LED flashing

Amber

twice every 40 seconds

Off

Power LED on (

Green

)

+44 (0) 1691 664 100 [email protected] www.aico.co.uk

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/silence the unit

Sound Emitted

Loud continual signal (3 pulses, followed by a pause. Repeated)

Silent

1 Beeps every 40 seconds

1 Beep every 40 seconds

Silent

What This Means

Dangerous levels of CO has been detected

The detector has alarmed previously (within 24 hours)

Sensor Fault

Low Battery

Normal Operating Mode

Required Action

Follow Emergency Procedures

Check appliances and reset detector memory by holding down the Test & Hush button for 20 seconds

Replace the Alarm

Replace the Alarm

None

Page 26 of 51

FirstAlert SCO5

Page 27 of 51

Contact Details

Telephone

Email

Website

Main Features

Feature

Power LED (

Green

)

CO/Smoke LED (

Red

)

Test/Silence

Operating Features

Light Indicator

CO LED flashing

Red

. Power/Smoke

LED off

Power/Smoke LED flashing

Red

. CO

LED off

Off

LED has 3 rapid flashes together with chirps

Power LED flashing

Green

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Function

Indicates that the unit is receiving power

Indicates an emergency CO/Smoke situation

Used to test/silence the unit

Sound Emitted

4 beeps, pause, 4 beeps, pause

3 beeps, pause, 3 beeps, pause

Chirps once per minute

Three chirps per minute

5 chirps per minute

What This Means

Dangerous levels of CO has been detected

Dangerous levels of Smoke has been detected

Low Battery

Fault

End of Life

Required Action

Follow Emergency Procedures

Follow Emergency Procedures

Replace batteries

If product is still under warranty contact ‘technical support’ if not replace alarm

Replace the Alarm

Page 28 of 51

FirstAlert SCO7

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Feature

Power LED (

Green

)

CO/Smoke LED (

Red

)

Test/Silence

Operating Features – Part 1 of 2

Function

Indicates that the unit is receiving power

Indicates an emergency CO/Smoke situation

Used to test/silence the unit

What This Means Light Indicator

CO LED flashing

Red

. Power/Smoke

LED off

Power/Smoke LED flashing

Red

. CO

LED off

Off

Sound Emitted

4 beeps, pause, 4 beeps, voice

(“Warning, evacuate carbon monoxide in ‘location’. Evacuate.”

“___ppm”.)

3 beeps, pause, 3 beeps, voice

(“Warning, evacuate smoke in

‘location’. Evacuate.”)

Chirps once per minute; Voice:

“Replace battery in ‘Location’ every 5 hours”

FirstAlert

Dangerous levels of CO has been detected

Dangerous levels of Smoke has been detected

Low Battery

SCO7

Page 29 of 51

Page 1 of 2

Required Action

Follow Emergency Procedures

Follow Emergency Procedures

Replace batteries

Page 2 of 2

Operating Features – Part 2 of 2

Light Indicator

LED has 3 flashes together with chirps

Power LED flashing

Green

once a minute

Sound Emitted

Three chirps every minute; Voice:

“Detector error in ‘Location’, please see manual” every 5 hours

5 chirps every minute; Voice:

“Detector error in ‘Location’, please see manual.” Repeated every 5 hours.

What This Means

Fault

End of Life

Required Action

If product is still under warranty contact ‘technical support’ if not replace alarm

Replace the Alarm

Page 30 of 51

FirstAlert GCO1

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Feature

Green

LED

Red

LED

Peak Level

Test/Silence

Digital Display

Operating Features – Part 1 of 2

Function

Indicates that the unit is receiving power

Indicates an emergency CO/Gas situation

Recalls highest CO level recorded (within 24 hours)

Used to Test/Silence the unit

Visual display of product’s indicators

Digital Screen Light Indicator Sound Emitted What This Means

Red

LED flashing in sync with alarm

4 beeps, pause. Repeating.

Page 1 of 2

Required Action

Dangerous levels of CO has been detected

Follow Emergency Procedures

Red

LED flashing in sync with alarm

FirstAlert

1 beeps per second

Dangerous levels of Gas has been detected

Follow Emergency Procedures

GCO1

Page 2 of 2

Page 31 of 51

Operating Features – Part 2 of 2

Digital Screen Light Indicator

Green

LED flashing 5 times per minute in sync with chirps

Green

LED flashing 3 times per minute in sync with chirps

OFF

Sound Emitted

5 chirps per minute

3 chirps per minute

Single chirp per minute

Green

LED on Silent

What This Means

End of Life

Required Action

Replace the Alarm

Malfunction

Low/Missing Battery

Normal Operating Mode

Replace the Alarm

Replace/Insert batteries

None

Page 32 of 51

FirstAlert

Contact Details

Telephone

Email

Website

Main Features

Feature

Red

LED

Test/Silence button

Operating Features

Light Indicator

Red

LED flashing rapidly

Red

LED flashing 5 times per minute in sync with chirps

Red

led flashing 3 times per minute in sync with chirps

Red

LED flashing once per minute

Red

LED flashing once per minute

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Function

Indicator of different alarm states

Used to test/silence the unit

Sound Emitted

Loud signal (4 beeps, pause, 4 beeps. Repeating)

5 chirps per minute

3 chirps per minute

Single chirp per minute

None

What This Means

Dangerous levels of CO has been detected

End of Life

Malfunction

Low Battery

Normal Operating Mode

CO400

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace the Alarm

Replace Batteries

None

Page 33 of 51

FirstAlert SCO500

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Feature

Power/Smoke LED

(

Green

/

Red

)

CO LED (

Red

)

Test/Silence button

Function

Indicates that the unit is receiving power/Indicates an emergency smoke situation

Indicates an emergency CO

Used to test/silence the unit

Operating Features – Part 1 of 2

What This Means Light Indicator

Power/Smoke LED: Off

CO LED: During Alarm: Flashes

Red

in sync with the alarm.

After Alarm: Flashes

Red

(On for 2 seconds/Off for 2 seconds)

Power Smoke LED: During Alarm:

Flashes

Red

in sync with alarm.

After Alarm: Flashes

Red

(On for 2 seconds/Off for 2 seconds)

CO LED: Off

Sound Emitted

Alarm: 4 beeps, pause, 4 beeps, voice (Repeated)

Voice: “Warning, evacuate carbon monoxide in [Location]. Evacuate,”

“___ ppm.”

Alarm: 3 beeps, pause, 3 beeps, voice

(Repeated)

Voice: “Warning, evacuate smoke in [Location]. Evacuate”

Dangerous levels of CO has been detected

Dangerous levels of Smoke has been detected

Page 34 of 51

Page 1 of 2

Required Action

Follow Emergency Procedures

Follow Emergency Procedures

FirstAlert

Operating Features – Part 2 of 2

Light Indicator

Power/Smoke LED: flashing

Red

5 times per minute

Power/Smoke LED: flashing

Green

3 times once a minute. CO LED: Off

Power/Smoke LED: flashing

Green

(On for 2 seconds/Off for 2 seconds)

CO LED: Off

Power/Smoke LED: Flashing

Green

once per minute

CO LED: Off

Sound Emitted

Horn: 5 chirps every minute

Voice: “Detector error in

[Location], please see manual.”

Repeated every 5 hours

Horn: 3 chirps every minute

Voice: “Detector error in

[Location].” Repeated every 5 hours

Chirps once a minute

Voice: “Replace battery in

[Location].” Repeated every 5 hours

Silent

SCO500

What This Means

End of Life

Malfunction

Low Battery

Normal Operating Mode

Page 2 of 2

Required Action

Replace the Alarm

Replace the Alarm

Replace Batteries

None

Page 35 of 51

FirstAlert

Contact Details

Telephone

Email

Website

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Main Features

Feature

Power/Alarm LED (

Red

)

Function

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit Test/Silence Button

Operating Features

Light Indicator

Power/Alarm LED flashing

Red

rapidly

Power/Alarm LED flashing

Red

rapidly 5 times per minute in sync with chirps

Power/Alarm LED flashing

Red

3 times per minute in sync with chirps

Power/Alarm LED flashing

Red

once per minute

Power/Alarm LED flashing

Red

once per minute

Sound Emitted

Loud signal (4 beeps, pause, 4 beeps. Repeating)

5 chirps per minute

3 chirps per minute

Single chirp per minute

None

What This Means

Dangerous levels of CO has been detected

End of Life

Malfunction

Low Battery

Normal Operating Mode

CO250

Required Action

Replace the Alarm

Replace the Alarm

Replace Batteries

None

Follow Emergency Procedures

Page 36 of 51

FirstAlert

Contact Details

Telephone

Email

Website

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Main Features

Feature

Power/Alarm LED (

Red

)

Function

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit Test/Silence Button

Operating Features

Light Indicator

Power/Alarm LED flashing

Red

rapidly

Power/Alarm LED flashing

Red

rapidly 5 times per minute in sync with chirps

Power/Alarm LED flashing

Red

3 times per minute in sync with chirps

Power/Alarm LED flashing

Red

once per minute

Power/Alarm LED flashing

Red

continuously

Sound Emitted

Loud signal (4 beeps, pause, 4 beeps. Repeating)

5 chirps per minute

3 chirps per minute

Single chirp per minute

None

What This Means

Dangerous levels of CO has been detected

End of Life

Malfunction

Low Battery

Normal Operating Mode

CO600

Required Action

Replace the Alarm

Replace the Alarm

Replace Batteries

None

Follow Emergency Procedures

Page 37 of 51

FirstAlert CO605

Contact Details

Telephone

Email

Website

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Main Features

Feature

Power/Alarm LED (

Red

)

Test/Silence Button

Function

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit

Operating Features – Part 1 of 2

Light Indicator

Power/Alarm LED flashing

Red

in sync with alarm

Power/Alarm LED flashing

Red

rapidly 5 times per minute in sync with chirps

Power/Alarm LED flashing

Red

3 times per minute in sync with chirps

Power/Alarm LED flashing

Red

once per minute

Power/Alarm LED flashing

Red

continuously

Sound Emitted

Loud signal (4 beeps, pause, 4 beeps. Repeating)

5 chirps per minute

3 chirps per minute

Single chirp per minute

None

What This Means

Dangerous levels of CO has been detected

End of Life

Malfunction

Low Battery

Normal Operating Mode (AC)

Page 38 of 51

Page 1 of 2

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace the Alarm

Replace Batteries

None

FirstAlert

Operating Features – Part 2 of 2

Light Indicator

Power/Alarm LED flashing

Red

continuously

Sound Emitted

None

SCO605

What This Means

Normal Operating Mode (Battery

Back-Up)

Page 2 of 2

Required Action

None

Page 39 of 51

FirstAlert CO615

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Feature

Power/Alarm LED

(

Green

/

Red

)

Test/Silence Button

Peak Level Button

Digital Display

Operating Features

Digital Screen

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit

Peak Level Button

Visual display of product’s indicators

Light Indicator Sound Emitted What This Means

Red

LED flashing in sync with alarm

Dangerous levels of CO has been detected

4 beeps, pause. Repeating.

Green

LED flashing 5 times per minute in sync with chirps

5 chirps per minute End of Life

Green

LED flashing 3 times per minute in sync with chirps

3 chirps per minute Malfunction

Page 1 of 2

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace the Alarm

Page 40 of 51

FirstAlert

Operating Features – Part 2 of 2

Digital Screen Light Indicator

Power/Alarm LED on

Green

(if

AC power is present)

Power/Alarm LED Off (if AC power is not present)

Green

LED on

Sound Emitted

Single chirp per minute

Silent

GCO1

What This Means

Low/Missing Battery

Normal Operating Mode

Page 2 of 2

Required Action

Replace/Insert battery

None

Page 41 of 51

FirstAlert PC900V

Contact Details

Telephone

Email

Website

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Main Features

Feature

Power LED (

Green

/

Red

)

Test/Silence Button

Function

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit

Operating Features – Part 1 of 2

Light Indicator

Power LED: flashing

Red

Power LED: flashes

Red

Power LED: flashing

Green

five times per minute

Sound Emitted

Voice: “Warning, evacuate carbon monoxide in [Location]. Evacuate.”

“___ ppm.”

Horn: 4 beeps, pause, 4 beeps, voice

Voice: “Warning, evacuate smoke in [Location]. Evacuate.”

Horn: 3 beeps, pause, 3 beeps, voice

Voice: “Detector error in

[Location], please see manual.”(repeated every 5 hours)

Horn: 5 chirps every 5 minutes

What This Means

Dangerous levels of CO has been detected

Dangerous levels of Smoke has been detected

End of Life

Page 42 of 51

Page 1 of 2

Required Action

Replace the Alarm

Follow Emergency Procedures

Follow Emergency Procedures

FirstAlert

Operating Features – Part 2 of 2

Light Indicator

Power LED: three

Green

flashes approximately once per minute

Power LED: flashes

Green

approximately once per minute

Power LED: flashes

Green

once a minute

Sound Emitted

Voice: “Detected error in

[Location], please see manual.”

(repeated every 5 hours)

Horn: 3 chirps every minute

Voice: “Replace battery in

[Location].” (repeated every 5 hours)

Horn: chirps once a minute

Silent

PC900V

What This Means

Malfunction

Low Battery

Normal Operating Mode

Page 2 of 2

Required Action

Replace the Alarm

Replace Batteries

None

Page 43 of 51

FirstAlert CO710

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu

Feature

Test Button

Silence Button

Digital Display

Operating Features

Digital Screen Light Indicator

Used to test the unit

Used to silence the unit

Visual display of product’s indicators

Sound Emitted

NA Repeating 4 beeps, pause

What This Means

Dangerous levels of CO has been detected

Required Action

Follow Emergency Procedures

NA 3 chirps every minute Malfunction Replace the Alarm

NA

NA

5 chirps every minute

Silent

End of Life

Normal Operating Mode

(Displaying Temperature)

Replace the Alarm

None

Page 44 of 51

Contact Details

BRK

Page 45 of 51

CO4000EN

Telephone

Email

Website

+44 (0) 1452 877 570 [email protected] www.brkelectronics.eu

Main Features

Feature

Power/Alarm LED (

Red

)

Function

Indicates that the unit is receiving power/Indicates an emergency CO situation

Used to test/silence the unit Test/Silence Button

Operating Features

Light Indicator

Power/Alarm LED flashes

Red

rapidly

Red

LED flashes

Power/Alarm LED flashes

Red

once every minute

Power/Alarm LED flashes

Red

once every minute

Sound Emitted

Repeating 4 beeps, pause

3 chirps every minute

1 chirp every minute

Silent

What This Means

Dangerous levels of CO has been detected

Malfunction/End of Life

Low Battery

Normal Operating Mode

Required Action

Follow Emergency Procedures

Replace the Alarm

Replace Batteries

None

Page 46 of 51

BRK

Contact Details

Telephone

Email

Website

Main Features

Feature

Power LED (

Green

)

Fault LED (

Yellow

)

Alarm LED (

Red

)

Test/Reset Button

Operating Features

Light Indicator

Power LED flashes

Red

Off

Off

Fault LED is on

Yellow

Fault LED flashes

Yellow

Power LED is on

Green

+44 (0) 1452 877 570 [email protected] www.brkelectronics.eu

Function

Indicates that the unit is receiving power and is fully operational

Indicates low battery/fault/end of life

Indicates an emergency situation

Used to test/reset/silence the unit

Sound Emitted

Repeating 4 beeps, pause

Repeating 4 beeps, pause

3 short beeps every minute

2 short beeps every minute

Single beep every minute

Silent

What This Means

Dangerous levels of CO has been detected

Dangerous levels of CO has been detected at an interconnected alarm

End of Life

Fault

Low Battery

Normal Operating Mode

CO850

Required Action

Follow Emergency Procedures

Follow Emergency Procedures

Replace the Alarm

Replace the Alarm

Replace the Alarm

None

Page 47 of 51

NEST PROTECT

Contact Details

Telephone

Email

Website

Main Features

+44 (0) 8081 692 307 (Support line – Mon-Fri from 07:00 to 19:00 –

Sat-Sun from 09:00 to 17:00) https://nest.com/uk/support/email-us/ https://nest.com/uk/support/smoke-co-alarm/

Feature

Green Light Indicator

Light Ring (

Blue

)

Light Ring (

Yellow

)

Light Ring (

Red

)

White

Light

Nest Button

Function

Indicates that the unit is receiving AC power and is fully operational

Indicates that the unit is in testing mode

Indicates a build-up of CO/Smoke, low battery and that the alarm has been hushed

Indicates an emergency CO/Smoke situation and that the alarm has been hushed

Pathlight in darkness

Used to test/silence the unit

Operating Features – Part 1 of 3

Light Indicator

Light pulses

Red

Light pulses

Red

Sound Emitted

“Emergency, there’s carbon monoxide in (room name). Move to fresh air now.”

“Emergency, there’s smoke in

(room name).”

What This Means

The carbon monoxide in the room has reached emergency levels

The smoke in the room has reached emergency levels

Page 1 of 2

Follow Emergency Procedures

Required Action

Follow Emergency Procedures

Page 48 of 51

NEST

Operating Features – Part 2 of 3

Light Indicator

Light pulses

Red

Light pulses

Red

Light pulses

Yellow

Light pulses

Yellow

Light pulses

Yellow

or

Red

None

None

Sound Emitted

“Emergency, there’s carbon monoxide in (room name). Move to fresh air now.”

“Emergency, there’s smoke in

(room name).”

“Heads-up, there’s carbon monoxide in the (room name). The alarm may sound.”

“Heads-up, there’s smoke in the

(room name). The alarm may sound.”

“Smoke Alarm has been hushed,” or “Carbon Monoxide Alarm has been hushed.”

Voice: “Nest product has expired.

Replace it now.”

Horn: Two chirps every 60 seconds

Voice: “The sensors have failed in the (room name), replace nest protect now.”

Horn: Single chirp every 60 seconds

PROTECT

What This Means

The carbon monoxide in the room has reached emergency levels

The smoke in the room has reached emergency levels

Carbon monoxide levels are rising.

This heads-up will occur if carbon monoxide levels stay at 70ppm for

60-240 minutes.”

Smoke levels are rising

You’ve hushed an alert

End of Life

Malfunction

Page 2 of 2

Required Action

Follow Emergency Procedures

Call the Emergency Services

Follow Emergency Procedures

Follow Emergency Procedures

Follow Emergency Procedures

Replace the Alarm

Clean with compressed air. If the problem persists, replace it

Page 49 of 51

NEST

Operating Features – Part 3 of 3

Light Indicator

Light pulses

Yellow

Sound Emitted

Voice: “The battery is very low in the (room name). Replace the battery now.”

Horn: Single chirp every 60 seconds

PROTECT

What This Means

Batteries have been depleted

Page 3 of 3

Required Action

Replace Batteries

Page 50 of 51

Light pulses

Blue

light rotating

White Light

Green

Yellow

Light is on

Green

Light pulses once after lights have been switched off at night

“The battery is low in the (room name). Replace the battery soon.”

“Ready, press to test.”

Silent

Silent

Silent

Low battery

To setup or run a manual test

Pathway lights your way as you pass under it

The unit has tested its sensors and batteries to confirm they are working correctly

The product is connected to AC power and is fully operational

Replace Batteries

Press the Nest button. Nest Protect will walk you through next steps.

None

None

None

Page 51 of 51