Carbon Monoxide Alarm Guide
This CO detector guide has been produced to help Operatives identify the status of an alarm to ensure the correct action is taken when called to a potential CO activation. Relevant information has been extracted from the user manuals to help assist with the identification of the operating mode of CO detectors that you may encounter so you can establish the correct action to take.
If you encounter an alarm that is not included within this guide then you can check the availability of the instructions with the end user. Where an alarm is sounding and you cannot identify the mode then always take the safest course of action by making the situation safe and advising the consumer to have the appliances checked by a Gas Safe registered installer.
All CO detectors manufactured for the UK market have to meet the requirements of BS EN 50291. This standard sets the minimum requirements for the design and manufacturer of CO detector . More recent detectors have enhanced functionality, such as LCD displays that provide a greater level of information to the homeowner.
Placement Of CO detectors
Correct location of the CO detector is an important to ensure the CO detector is operating in an effective zone and helps to eliminate false activations.
The recommendation for the placement of a CO detector is:
in every room that contains a fuel burning appliance,
at least 300 mm from any wall (for ceiling mounted alarms)
at least 150 mm from the ceiling, above the height of any door or window (for wall mounted alarms)
between 1 and 3 m (measured horizontally) from the potential source of CO
CO Detectors must not be placed in the following:
in an enclosed space,
where it can be obstructed,
directly above a sink,
Page 1 of 51
next to a door, window, extractor fan, air vent or similar ventilation opening,
where the temperature may drop below –5 ºC or exceed 40 ºC.
Where a premises has multiple fuel burning appliances in different rooms, the standard recommends that if there are restrictions in placing an alarm in each room that the priority should be given to putting a detector in rooms containing flueless or open-flued appliances.
CO Detectors are designed to sound a continual audible alarm when the following criteria is met:
CO Concentration Without Alarm Before
30 PPM
50 PPM
100 PPM
300 PPM
120 mins
60 mins
10 mins
-
With Alarm Before
-
90 mins
40 mins
3 mins
Where a detector activates when the above criteria is met then the alarm must continue to sound until the CO PPM readings drop below 50 PPM. When the CO reading drops below this threshold then the alarm should stop alerting within 10 minutes. The CO detection functionality on an alarm is still operating even when the detector is indicating low battery.
Many new detectors contain an LCD display, which indicates the highest PPM reading obtained. This value is displayed even when the alarm stops activating, however it is important to note that the display can be reset therefore removing any information on activation.
Dual Mode CO detectors
It is becoming more common to encounter alarms that have a dual mode, typically these are combined with smoke alarms in a single unit. In some cases they may also contain other functions, such as panic alerts for elderly customers.
Even when you encountered a combined unit the CO element of the alarm must operate independently of any other mode and this must comply with the mimum requirements set out in the CO alarm standard.
Page 2 of 51
FireAngel
CO-9B
Kidde
10SCO
Honeywell
CO Detector Catalogue
Ei Electronics FirstAlert
Ei208
SCO500
CO605
CO615
PC900V
BRK
NEST
PROTECT
Page 3 of 51
FireAngel
Contact Details
Telephone
Website
08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/
Main Features
Feature
Power LED (
Green
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Alarm LED flashing
Red
once per second
Function
Indicates that the unit is receiving power and is fully operational
Indicates and emergency situation
Used to test/reset/silence the unit
Sound Emitted
Loud audible signal
What This Means
Dangerous levels of CO has been detected
Off
Power LED flashing
Green
once per minute
Single chirp once per minute
Silent
Low battery/Fault/End of Life
Normal Operating Mode
CO-9B
Required Action
Follow Emergency Procedures
Replace batteries. If warning indicators persist despite having new batteries and the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately
None
Page 4 of 51
FireAngel CO-9D
Page 5 of 51
Contact Details
Telephone
Website
08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/
Main Features
Feature
Power LED [ ] (
Green
)
Alarm LED [ ] (
Red
)
Function
Indicates that the unit is receiving power and is fully operational
Indicates an emergency situation
Test/Mode Button Switch between CO/Temperature view and to test/silence the unit
Operating Features – Part 1 of 2
Digital Screen Light Indicator Sound Emitted What This Means
Alarm [ ] LED flashing
Red
once per second
Loud audible signal
Power [ ] LED flashing
Green
once per minute
Power [ ] LED flashing
Green
once per minute
Power [ ] LED flashing
Green
once per minute
Silent
Silent
Single chirp once per minute
Dangerous levels of CO has been detected
Alarm has been silenced during a recent alarm situation – this can be identified from the presence of a PPM reading on the silence alarm symbol [ ] on the display
The peak level symbol[ ] indicates that CO has been detected in your absence
A fault has been detected in the alarms sensor/circuitry settings
Power [ ] LED flashing
Green
once per minute
Single chirp once per minute
Power Pack Low
Power [ ] LED flashing
Green
once per minute
Power [ ] LED flashing
Green
once per minute
Silent
Silent
The spanner icon [ ] indicates that the alarm is in sensor test mode
Temperature Display View
Required Action
Follow Emergency Procedures
If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately
Perform sensor test or end the test by holding down the Test/Mode button until the spanner icon disappears
To switch between CO and temperature view, press the Test/Mode button briefly
Page 6 of 51
Contact Details
FireAngel CO-9X
Page 7 of 51
Telephone
Website
08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/
Main Features
Feature
Power LED (
Green
)
Fault LED (
Yellow
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Alarm LED flashing
Red
once per second
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault
Indicates an emergency situation
Used to test/reset/silence the unit
Sound Emitted
Loud audible signal
What This Means
Dangerous levels of CO has been detected
Fault LED
Yellow
flashing once per minute
Power LED flashing
Green
once per minute
Single chirp once per minute
Silent
Low Battery/Fault
Normal Operating Mode
Required Action
Follow Emergency Procedures
If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately
None
Page 8 of 51
FireAngel
Contact Details
Telephone
Website
08001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/
Main Features
Feature
Power LED (
Green
)
Fault LED (
Yellow
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Alarm LED flashing
Red
once per second
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/reset/silence the unit
Sound Emitted
Loud audible signal
What This Means
Dangerous levels of CO has been detected
Fault LED flashing
Yellow
once per minute
Power LED flashing
Green
once per minute
Single chirp once per minute
Silent
Low Battery/Fault/End of life
Normal Operating Mode
CO-9X-10
Required Action
Follow Emergency Procedures
If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately
None
Page 9 of 51
FireAngel
Contact Details
Telephone
Website
+44 (0) 8001 412 561 (support line – Mon-Fri from 09:00 to 17:00) [email protected] www.fireangel.co.uk/product-category/carbon-monoxide-alarms/
Main Features
Feature
Power LED (
Green
)
Fault LED (
Yellow
)
Alarm LED (
Red
)
Test/Silence Button
Operating Features
Light Indicator
Alarm LED flashing
Red
once every 5 seconds
Fault LED flashing
Yellow
once per minute
Fault LED flashing Yellow once per minute
Power LED flashing Green once per minute
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/silence the unit
Sound Emitted
Four chirps repeated
Single chirp once per minute (In sync with fault LED flashes)
Single chirp once per minute (nonconcurrent with fault LED flashes)
Silent
What This Means
Dangerous levels of CO has been detected
Low Battery/End of Life
Sensor Fault
Normal Operating Mode
W2-CO-10X
Required Action
Follow Emergency Procedures
If the product is still under warranty contact technical support for advice. If the product is no longer under warranty replace it immediately
None
Page 10 of 51
Kidde
Contact Details
Telephone
Website
Main Features
Feature
Operate LED (
Green
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Alarm LED flashing
Red
Alarm LED on (
Red
)
Alarm LED flashing
Red
twice every 30 seconds
Alarm LED flashing
Red
once every 30 seconds
Alarm LED flashing
Red
once per minute
Operate LED flashing
Green
once every 30 seconds
08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates an emergency situation/fault/low batteries/end of life
Used to test/reset/silence the unit
Sound Emitted
Loud continual signal (4 beeps – 5 seconds pause – 4 beeps…)
Constant audible signal
Two chirps every 30 seconds
Single chirp every 30 seconds
Single chirp once per minute
Silent
What This Means
Dangerous levels of CO has been detected
Malfunction
End of life
Fault
Low Battery
Normal Operating Mode
5CO
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace Batteries
None
Page 11 of 51
Kidde
Contact Details
Telephone
Website
Main Features
Feature
Operate LED (
Green
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Alarm LED flashing
Red
Alarm LED on (
Red
)
Alarm LED flashing
Red
twice every 30 seconds
Alarm LED flashing
Red
once every 30 seconds
Alarm LED flashing
Red
once per minute
Operate LED flashing
Green
once every 30 seconds
08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates an emergency situation/fault/low batteries/end of life
Used to test/reset/silence the unit
Sound Emitted
Loud continual signal (4 beeps – 5 seconds pause – 4 beeps…)
Constant audible signal
Two chirps every 30 seconds
Single chirp every 30 seconds
Single chirp once per minute
Silent
What This Means
Dangerous levels of CO has been detected
Malfunction
End of life
Fault
Low Battery
Normal Operating Mode
7CO
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace Batteries
None
Page 12 of 51
Kidde
Contact Details
Telephone
Website
Main Features
Feature
Operate LED (
Green
)
Alarm LED (
Red
)
Test/Reset Button
Peak Level Button
Digital Display
+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates an emergency situation/fault/low batteries/end of life
Used to test/reset/silence the unit
Displays the peak CO reading
Visual display of product’s indicators
Operating Features
Digital Screen Light Indicator
Alarm LED flashing
Red
and
CO level on display
Sound Emitted
Full alarm (4 beeps – pause – 4 beeps)(repeating)
Constant audible signal (not full alarm)
Two chirps once every 30 seconds
What This Means
Dangerous levels of CO has been detected
Malfunction Alarm LED on (
Red
)
Alarm LED flashing
Red
twice every 30 seconds
End of Life
Alarm LED flashing
Red
Single chirp once every 30 seconds
Alarm LED flashing
Red
once per minute
Single chirp once per minute
1 beep, then 2 sets of 4 beeps, followed by 1 beep
Alarm LED flashing
Red
Operate LED flashing
Green
once every 30 seconds
Silent
Fault
Low Battery
Successful test or reset sequence in operation
Normal Operating Mode
7DCO
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace Batteries
None
None
Page 13 of 51
Kidde
Contact Details
Telephone
Website
Main Features
Feature
Operate LED (
Green
)
Fault LED (
Amber
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features – Part 1 of 2
Light Indicator
Alarm LED on (
Red
)
Off
Alarm LED flashing
Red
twice every 30 seconds and fault LED flashing
Amber
once per second
Fault LED flashing
Amber
once every
30 seconds and operate LED (
Green)
blinks error code every other 30 seconds
Fault LED flashing
Amber
once every
30 seconds
Alarm LED flashing
Red
once per minute
Operate LED flashing
Green
once every
30 seconds
+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/reset/silence the unit
Sound Emitted
Loud continuous signal (four loud alarm sounds, repeated for four minutes, followed by two patterns per minute)
Constant signal
Two chirps every 30 seconds
Single beep every 30 seconds
One beep per minute
Silent
Silent
What This Means
Dangerous levels of CO has been detected
Malfunction
End of Life
Fault
Low Battery
Historical event in last 14 days
Normal Operating Mode
Page 14 of 51
10LLCO
Required Action
Follow Emergency Procedures
Replace the Alarm
If cold allow unit to warm up for a couple of hours then replace if still beeping
Follow Emergency Procedures
None
Kidde 10LLDCO
Page 15 of 51
Contact Details
Telephone
Website
Main Features
Feature
Operate LED (
Green
)
Fault LED (
Amber
)
Alarm LED (
Red
)
Test/Reset Button
Peak Level Button
Operating Features
Digital Screen
08009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/reset/silence the unit
Displays the peak CO reading
Light Indicator
Alarm LED flashing
Red
Sound Emitted
Continual audible signal
What This Means
Dangerous levels of CO has been detected
Malfunction
Required Action
Follow Emergency
Procedures
Off
Alarm LED flashing
Red
twice every 30 seconds. Fault LED flashing
Amber
once per second
Fault LED flashing
Amber
once per second and operate LED (
Green
) flashing error code every other 30 seconds
Fault LED flashing
Amber
once per second
Alarm LED flashing
Red.
Operate (
Green
) and Fault (
Amber
) LED on
Operate LED flashing
Green
every 30 seconds
Constant signal
Two chirps every 30 seconds
Single chirp every 30 seconds
Single chirp once per minute
1 beep, then 2 sets of 4 beeps, followed by 1 beep
Silent
End of Life
Replace the Alarm
Fault
Low Battery
Successful test or reset sequence in operation
If cold allow unit to warm up for a couple of hours then replace if still beeping
None
Normal Operating Mode None
Page 16 of 51
Contact Details
Telephone
Website
Main Features
Feature
Green
LED
Red
LED
Test/Reset/Hush
Operating Features
Light Indicator
+44 (0) 8009 170 722 [email protected] www.TenYCO.kiddefyrne0cs.co.uk
Function
Indicates that the unit is receiving power
Indicates an emergency situation
Used to test/reset/silence the unit
Red
LED flashes
Red
LED flashes
Off
Red
LED flashes
Red
LED flashes once every minute
Green
LED flashes every 30 seconds
Sound Emitted
Alarm: Four short beeps followed by the verbal message
Verbal: “WARNING! CARBON
MONOXIDE!” After four minutes the alarm/voice will sound once every minute until the unit is reset
Alarm: Three long beeps followed by the verbal message
Verbal: “FIRE! FIRE!”, repeated until the smoke is eliminated
2 chirps every 30 seconds
Single chirp every 30 seconds
Voice: “LOW BATTERY”, this cycle will occur for the first hour. After the first hour the voice message “LOW
BATTERY” will sound once every 15 minutes.
Silent
Honeywell
What This Means
Dangerous levels of CO has been detected
Dangerous levels of Smoke has been detected
End of Life
Malfunction
Low Battery
Normal Operating Mode
XC70
Page 17 of 51
Required Action
Follow Emergency Procedures
Call Emergency Services
Replace the Alarm
Replace the Alarm
Replace Batteries
None
Contact Details
Telephone
Website
Main Features
01202 645 577 [email protected] www.homesafety.honeywell.com
Feature
Power LED (
Green
)
Fault LED (
Yellow
)
Ventilate LED (
Blue
)
Alarm LED (
Red
)
Test/Hush button
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery or fault
Early warning of CO build-up
Indicates an emergency situation
Used to test/silence the unit
Operating Features – Part 1 of 2
Light Indicator
Alarm LED flashing
Red
Sound Emitted
Continuous 4 chirps for 60 minutes then once every 30 seconds
Off
Alarm LED flashing
Red
once per minute
Continuous 4 chirps
Chirp once per minute
Honeywell
What This Means
Dangerous levels of CO has been detected
Dangerous levels of CO has been detected by another interconnected CO alarm
Dangerous levels of CO was detected whilst user was absent.
Currently, no dangerous CO level present
XC70
Operating Features – Part 2 of 2
Light Indicator Sound Emitted What This Means
Page 18 of 51
Check Appliances
Page 2 of 2
Required Action
Required Action
Follow Emergency Procedures
Follow Emergency Procedures
Off
Ventilate LED flashing
Blue
1 (2, or
3) times once every 30 seconds, increasing the longer CO is present
Fault LED flashing
Yellow
3 times per minute
Fault LED flashing
Yellow
once per minute
Power LED flashing
Green
once per minute
Continuous 3 chirps
1 (2, or 3) chirps once every 30 seconds, increasing the longer CO is present
3 chirps per minute
Chirp once per minute
Fire detected by an interconnected fire alarm
A dangerous CO condition is building up.
The wireless module is not working correctly
End of Life
Silent Normal Operating Mode
Follow Emergency Procedures
Check Appliances
Refer to the wireless module manual for further details
Replace the Alarm
None
Page 19 of 51
Honeywell XC100
Page 20 of 51
Contact Details
Telephone
Website
Main Features
Feature
01202 645 577 [email protected] www.homesafety.honeywell.com
Function
Power LED (
Green
)
Fault LED (
Yellow
)
Ventilate LED (
Blue
)
Alarm LED (
Red
)
Test/Hush button
Operating Features – Part 1 of 2
Light Indicator
Alarm LED flashing
Red
Indicates that the unit is receiving power and is fully operational
Indicates low battery or fault
Early warning of CO build-up
Indicates an emergency situation
Used to test/silence the unit
Sound Emitted
Continuous 4 chirps for 60 minutes then once every 30 seconds
What This Means
Dangerous levels of CO has been detected
Off
Alarm LED flashing
Red
once per minute
Continuous 4 chirps
Chirp once per minute
Dangerous levels of CO has been detected by another interconnected CO alarm
Dangerous levels of CO was detected whilst user was absent. Currently, no dangerous CO level present
Fire detected by an interconnected fire alarm Off
Ventilate LED flashing
Blue
1 (2, or 3) times once every 30 seconds, increasing the longer CO is present
Continuous 3 chirps
1 (2, or 3) chirps once every 30 seconds, increasing the longer CO is present
A dangerous CO condition is building up.
Fault LED flashing
Yellow
3 times per minute
3 chirps per minute The wireless module is not working correctly
Fault LED flashing
Yellow
per minute
Power LED flashing
Green
once per minute
Chirp once per minute
Silent
End of Life
Normal Operating Mode
Required Action
Follow Emergency
Procedures
Refer to the wireless module manual for further details
Replace the Alarm
None
Page 21 of 51
Honeywell XC100D
Contact Details
Telephone
08009 170 722 [email protected]
Website
www.TenYCO.kiddefyrne0cs.co.uk
Main Features
Feature Function
Power LED (
Green
)
Fault LED (
Yellow
)
Ventilate LED (
Blue
)
Alarm LED (
Red
)
Test/Hush button
Indicates that the unit is receiving power and is fully operational
Indicates low battery or fault
Early warning of CO build-up
Indicates an emergency situation
Used to test/silence the unit
Visual display of product’s indicators Digital Display
Operating Features – Part 1 of 2
Digital Screen Light Indicator Sound Emitted What This Means
Power LED flashing
Green
Continuous 4 chirps for 60 minutes then once every 30 seconds
Dangerous levels of CO has been detected
Off Continuous 4 chirps
Dangerous levels of CO has been detected by another interconnected CO alarm
Page 1 of 2
Required Action
Follow Emergency Procedures
Page 22 of 51
Honeywell
Digital Screen Light Indicator
Alarm LED flashing
Red
once per minute
Alarm LED flashes
Red
once per minute
XC100D Page 2 of 2
Sound Emitted
Chirp once per minute
Chirp once per minute
Off Continuous 3 chirps
Ventilate LED flashing
Blue
1 (2, or 3) times once every 30 seconds, increasing the longer
CO is present
Fault LED flashing
Yellow
3 times every minute
1 (2, or 3) chirps once every 30 seconds, increasing the longer
CO is present
3 chirps per minute
What This Means
Dangerous levels of CO was detected whilst user was absent.
Currently, no dangerous CO level present
Dangerous levels of CO was detected whilst user was absent.
Currently, no dangerous CO level present
Fire detected by an interconnected fire alarm
Required Action
Follow Emergency Procedures
Contact Emergency Services
A dangerous CO condition is building up.
The wireless module is not working correctly
Follow Emergency Procedures
Refer to the wireless module manual for further details
Fault LED flashing
Yellow
once every minute
Chirp once per minute End of Life Replace the Alarm
Power LED flashing
Green
once every minute
Silent Normal Operating Mode None
Page 23 of 51
EI Electronics Ei208
Contact Details
Telephone
Website
+44 (0) 1691 664 100 [email protected] www.aico.co.uk
Main Features
Feature
Power LED (
Green
)
Fault LED (
Amber
)
Alarm LED (
Red
)
Test & Hush Button
Operating Features
Light Indicator
Alarm LED flashing
Red
1, 2 or 4 times every 2 seconds (the higher the CO concentration the more flashes)
Alarm LED flashing
Red
2, 4 or 8 times every 40 seconds (the higher the CO concentration the more flashes)
Fault LED flashing
Amber
3 times every 40 seconds
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/silence the unit
Sound Emitted
Continual audible signal
Silent
3 Beeps every 40 seconds
What This Means
Dangerous levels of CO has been detected
The detector has alarmed previously (within 24 hours)
End of Life
Page 1 of 2
Required Action
Follow Emergency Procedures
Check appliances and reset detector memory by holding down the Test & Hush button for 20 seconds
Replace the Alarm
Page 24 of 51
EI Electronics
Operating Features – Part 2 of 2
Light Indicator
Fault LED flashing
Amber
twice every 40 seconds
Fault LED flashing
Amber
once every 40 seconds
Power LED on
Green
Sound Emitted
2 Beeps every 40 seconds
1 Beep every 40 seconds
Silent
Ei208
What This Means
Sensor Fault
Low Battery
Normal Operating Mode
Page 2 of 2
Required Action
Replace the Alarm
Replace the Alarm
None
Page 25 of 51
EI Electronics E261ENRC
Contact Details
Telephone
Website
Main Features
Feature
Power LED (
Green
)
Fault LED (
Amber
)
Alarm LED (
Red
)
Test & Hush Button
Operating Features
Light Indicator
Alarm LED flashing
Red
Alarm LED flashing
Red
2, 4 or 8 times every 40 seconds (the higher the CO concentration the more flashes)
Fault LED flashing
Amber
twice every 40 seconds
Off
Power LED on (
Green
)
+44 (0) 1691 664 100 [email protected] www.aico.co.uk
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/silence the unit
Sound Emitted
Loud continual signal (3 pulses, followed by a pause. Repeated)
Silent
1 Beeps every 40 seconds
1 Beep every 40 seconds
Silent
What This Means
Dangerous levels of CO has been detected
The detector has alarmed previously (within 24 hours)
Sensor Fault
Low Battery
Normal Operating Mode
Required Action
Follow Emergency Procedures
Check appliances and reset detector memory by holding down the Test & Hush button for 20 seconds
Replace the Alarm
Replace the Alarm
None
Page 26 of 51
FirstAlert SCO5
Page 27 of 51
Contact Details
Telephone
Website
Main Features
Feature
Power LED (
Green
)
CO/Smoke LED (
Red
)
Test/Silence
Operating Features
Light Indicator
CO LED flashing
Red
. Power/Smoke
LED off
Power/Smoke LED flashing
Red
. CO
LED off
Off
LED has 3 rapid flashes together with chirps
Power LED flashing
Green
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Function
Indicates that the unit is receiving power
Indicates an emergency CO/Smoke situation
Used to test/silence the unit
Sound Emitted
4 beeps, pause, 4 beeps, pause
3 beeps, pause, 3 beeps, pause
Chirps once per minute
Three chirps per minute
5 chirps per minute
What This Means
Dangerous levels of CO has been detected
Dangerous levels of Smoke has been detected
Low Battery
Fault
End of Life
Required Action
Follow Emergency Procedures
Follow Emergency Procedures
Replace batteries
If product is still under warranty contact ‘technical support’ if not replace alarm
Replace the Alarm
Page 28 of 51
FirstAlert SCO7
Contact Details
Telephone
Website
Main Features
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Feature
Power LED (
Green
)
CO/Smoke LED (
Red
)
Test/Silence
Operating Features – Part 1 of 2
Function
Indicates that the unit is receiving power
Indicates an emergency CO/Smoke situation
Used to test/silence the unit
What This Means Light Indicator
CO LED flashing
Red
. Power/Smoke
LED off
Power/Smoke LED flashing
Red
. CO
LED off
Off
Sound Emitted
4 beeps, pause, 4 beeps, voice
(“Warning, evacuate carbon monoxide in ‘location’. Evacuate.”
“___ppm”.)
3 beeps, pause, 3 beeps, voice
(“Warning, evacuate smoke in
‘location’. Evacuate.”)
Chirps once per minute; Voice:
“Replace battery in ‘Location’ every 5 hours”
FirstAlert
Dangerous levels of CO has been detected
Dangerous levels of Smoke has been detected
Low Battery
SCO7
Page 29 of 51
Page 1 of 2
Required Action
Follow Emergency Procedures
Follow Emergency Procedures
Replace batteries
Page 2 of 2
Operating Features – Part 2 of 2
Light Indicator
LED has 3 flashes together with chirps
Power LED flashing
Green
once a minute
Sound Emitted
Three chirps every minute; Voice:
“Detector error in ‘Location’, please see manual” every 5 hours
5 chirps every minute; Voice:
“Detector error in ‘Location’, please see manual.” Repeated every 5 hours.
What This Means
Fault
End of Life
Required Action
If product is still under warranty contact ‘technical support’ if not replace alarm
Replace the Alarm
Page 30 of 51
FirstAlert GCO1
Contact Details
Telephone
Website
Main Features
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Feature
Green
LED
Red
LED
Peak Level
Test/Silence
Digital Display
Operating Features – Part 1 of 2
Function
Indicates that the unit is receiving power
Indicates an emergency CO/Gas situation
Recalls highest CO level recorded (within 24 hours)
Used to Test/Silence the unit
Visual display of product’s indicators
Digital Screen Light Indicator Sound Emitted What This Means
Red
LED flashing in sync with alarm
4 beeps, pause. Repeating.
Page 1 of 2
Required Action
Dangerous levels of CO has been detected
Follow Emergency Procedures
Red
LED flashing in sync with alarm
FirstAlert
1 beeps per second
Dangerous levels of Gas has been detected
Follow Emergency Procedures
GCO1
Page 2 of 2
Page 31 of 51
Operating Features – Part 2 of 2
Digital Screen Light Indicator
Green
LED flashing 5 times per minute in sync with chirps
Green
LED flashing 3 times per minute in sync with chirps
OFF
Sound Emitted
5 chirps per minute
3 chirps per minute
Single chirp per minute
Green
LED on Silent
What This Means
End of Life
Required Action
Replace the Alarm
Malfunction
Low/Missing Battery
Normal Operating Mode
Replace the Alarm
Replace/Insert batteries
None
Page 32 of 51
FirstAlert
Contact Details
Telephone
Website
Main Features
Feature
Red
LED
Test/Silence button
Operating Features
Light Indicator
Red
LED flashing rapidly
Red
LED flashing 5 times per minute in sync with chirps
Red
led flashing 3 times per minute in sync with chirps
Red
LED flashing once per minute
Red
LED flashing once per minute
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Function
Indicator of different alarm states
Used to test/silence the unit
Sound Emitted
Loud signal (4 beeps, pause, 4 beeps. Repeating)
5 chirps per minute
3 chirps per minute
Single chirp per minute
None
What This Means
Dangerous levels of CO has been detected
End of Life
Malfunction
Low Battery
Normal Operating Mode
CO400
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace the Alarm
Replace Batteries
None
Page 33 of 51
FirstAlert SCO500
Contact Details
Telephone
Website
Main Features
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Feature
Power/Smoke LED
(
Green
/
Red
)
CO LED (
Red
)
Test/Silence button
Function
Indicates that the unit is receiving power/Indicates an emergency smoke situation
Indicates an emergency CO
Used to test/silence the unit
Operating Features – Part 1 of 2
What This Means Light Indicator
Power/Smoke LED: Off
CO LED: During Alarm: Flashes
Red
in sync with the alarm.
After Alarm: Flashes
Red
(On for 2 seconds/Off for 2 seconds)
Power Smoke LED: During Alarm:
Flashes
Red
in sync with alarm.
After Alarm: Flashes
Red
(On for 2 seconds/Off for 2 seconds)
CO LED: Off
Sound Emitted
Alarm: 4 beeps, pause, 4 beeps, voice (Repeated)
Voice: “Warning, evacuate carbon monoxide in [Location]. Evacuate,”
“___ ppm.”
Alarm: 3 beeps, pause, 3 beeps, voice
(Repeated)
Voice: “Warning, evacuate smoke in [Location]. Evacuate”
Dangerous levels of CO has been detected
Dangerous levels of Smoke has been detected
Page 34 of 51
Page 1 of 2
Required Action
Follow Emergency Procedures
Follow Emergency Procedures
FirstAlert
Operating Features – Part 2 of 2
Light Indicator
Power/Smoke LED: flashing
Red
5 times per minute
Power/Smoke LED: flashing
Green
3 times once a minute. CO LED: Off
Power/Smoke LED: flashing
Green
(On for 2 seconds/Off for 2 seconds)
CO LED: Off
Power/Smoke LED: Flashing
Green
once per minute
CO LED: Off
Sound Emitted
Horn: 5 chirps every minute
Voice: “Detector error in
[Location], please see manual.”
Repeated every 5 hours
Horn: 3 chirps every minute
Voice: “Detector error in
[Location].” Repeated every 5 hours
Chirps once a minute
Voice: “Replace battery in
[Location].” Repeated every 5 hours
Silent
SCO500
What This Means
End of Life
Malfunction
Low Battery
Normal Operating Mode
Page 2 of 2
Required Action
Replace the Alarm
Replace the Alarm
Replace Batteries
None
Page 35 of 51
FirstAlert
Contact Details
Telephone
Website
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Main Features
Feature
Power/Alarm LED (
Red
)
Function
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit Test/Silence Button
Operating Features
Light Indicator
Power/Alarm LED flashing
Red
rapidly
Power/Alarm LED flashing
Red
rapidly 5 times per minute in sync with chirps
Power/Alarm LED flashing
Red
3 times per minute in sync with chirps
Power/Alarm LED flashing
Red
once per minute
Power/Alarm LED flashing
Red
once per minute
Sound Emitted
Loud signal (4 beeps, pause, 4 beeps. Repeating)
5 chirps per minute
3 chirps per minute
Single chirp per minute
None
What This Means
Dangerous levels of CO has been detected
End of Life
Malfunction
Low Battery
Normal Operating Mode
CO250
Required Action
Replace the Alarm
Replace the Alarm
Replace Batteries
None
Follow Emergency Procedures
Page 36 of 51
FirstAlert
Contact Details
Telephone
Website
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Main Features
Feature
Power/Alarm LED (
Red
)
Function
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit Test/Silence Button
Operating Features
Light Indicator
Power/Alarm LED flashing
Red
rapidly
Power/Alarm LED flashing
Red
rapidly 5 times per minute in sync with chirps
Power/Alarm LED flashing
Red
3 times per minute in sync with chirps
Power/Alarm LED flashing
Red
once per minute
Power/Alarm LED flashing
Red
continuously
Sound Emitted
Loud signal (4 beeps, pause, 4 beeps. Repeating)
5 chirps per minute
3 chirps per minute
Single chirp per minute
None
What This Means
Dangerous levels of CO has been detected
End of Life
Malfunction
Low Battery
Normal Operating Mode
CO600
Required Action
Replace the Alarm
Replace the Alarm
Replace Batteries
None
Follow Emergency Procedures
Page 37 of 51
FirstAlert CO605
Contact Details
Telephone
Website
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Main Features
Feature
Power/Alarm LED (
Red
)
Test/Silence Button
Function
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit
Operating Features – Part 1 of 2
Light Indicator
Power/Alarm LED flashing
Red
in sync with alarm
Power/Alarm LED flashing
Red
rapidly 5 times per minute in sync with chirps
Power/Alarm LED flashing
Red
3 times per minute in sync with chirps
Power/Alarm LED flashing
Red
once per minute
Power/Alarm LED flashing
Red
continuously
Sound Emitted
Loud signal (4 beeps, pause, 4 beeps. Repeating)
5 chirps per minute
3 chirps per minute
Single chirp per minute
None
What This Means
Dangerous levels of CO has been detected
End of Life
Malfunction
Low Battery
Normal Operating Mode (AC)
Page 38 of 51
Page 1 of 2
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace the Alarm
Replace Batteries
None
FirstAlert
Operating Features – Part 2 of 2
Light Indicator
Power/Alarm LED flashing
Red
continuously
Sound Emitted
None
SCO605
What This Means
Normal Operating Mode (Battery
Back-Up)
Page 2 of 2
Required Action
None
Page 39 of 51
FirstAlert CO615
Contact Details
Telephone
Website
Main Features
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Feature
Power/Alarm LED
(
Green
/
Red
)
Test/Silence Button
Peak Level Button
Digital Display
Operating Features
Digital Screen
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit
Peak Level Button
Visual display of product’s indicators
Light Indicator Sound Emitted What This Means
Red
LED flashing in sync with alarm
Dangerous levels of CO has been detected
4 beeps, pause. Repeating.
Green
LED flashing 5 times per minute in sync with chirps
5 chirps per minute End of Life
Green
LED flashing 3 times per minute in sync with chirps
3 chirps per minute Malfunction
Page 1 of 2
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace the Alarm
Page 40 of 51
FirstAlert
Operating Features – Part 2 of 2
Digital Screen Light Indicator
Power/Alarm LED on
Green
(if
AC power is present)
Power/Alarm LED Off (if AC power is not present)
Green
LED on
Sound Emitted
Single chirp per minute
Silent
GCO1
What This Means
Low/Missing Battery
Normal Operating Mode
Page 2 of 2
Required Action
Replace/Insert battery
None
Page 41 of 51
FirstAlert PC900V
Contact Details
Telephone
Website
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Main Features
Feature
Power LED (
Green
/
Red
)
Test/Silence Button
Function
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit
Operating Features – Part 1 of 2
Light Indicator
Power LED: flashing
Red
Power LED: flashes
Red
Power LED: flashing
Green
five times per minute
Sound Emitted
Voice: “Warning, evacuate carbon monoxide in [Location]. Evacuate.”
“___ ppm.”
Horn: 4 beeps, pause, 4 beeps, voice
Voice: “Warning, evacuate smoke in [Location]. Evacuate.”
Horn: 3 beeps, pause, 3 beeps, voice
Voice: “Detector error in
[Location], please see manual.”(repeated every 5 hours)
Horn: 5 chirps every 5 minutes
What This Means
Dangerous levels of CO has been detected
Dangerous levels of Smoke has been detected
End of Life
Page 42 of 51
Page 1 of 2
Required Action
Replace the Alarm
Follow Emergency Procedures
Follow Emergency Procedures
FirstAlert
Operating Features – Part 2 of 2
Light Indicator
Power LED: three
Green
flashes approximately once per minute
Power LED: flashes
Green
approximately once per minute
Power LED: flashes
Green
once a minute
Sound Emitted
Voice: “Detected error in
[Location], please see manual.”
(repeated every 5 hours)
Horn: 3 chirps every minute
Voice: “Replace battery in
[Location].” (repeated every 5 hours)
Horn: chirps once a minute
Silent
PC900V
What This Means
Malfunction
Low Battery
Normal Operating Mode
Page 2 of 2
Required Action
Replace the Alarm
Replace Batteries
None
Page 43 of 51
FirstAlert CO710
Contact Details
Telephone
Website
Main Features
+44 (0) 8001 412 561 / +44 (0) 2477 717 570 [email protected] www.firstalert.eu
Feature
Test Button
Silence Button
Digital Display
Operating Features
Digital Screen Light Indicator
Used to test the unit
Used to silence the unit
Visual display of product’s indicators
Sound Emitted
NA Repeating 4 beeps, pause
What This Means
Dangerous levels of CO has been detected
Required Action
Follow Emergency Procedures
NA 3 chirps every minute Malfunction Replace the Alarm
NA
NA
5 chirps every minute
Silent
End of Life
Normal Operating Mode
(Displaying Temperature)
Replace the Alarm
None
Page 44 of 51
Contact Details
BRK
Page 45 of 51
CO4000EN
Telephone
Website
+44 (0) 1452 877 570 [email protected] www.brkelectronics.eu
Main Features
Feature
Power/Alarm LED (
Red
)
Function
Indicates that the unit is receiving power/Indicates an emergency CO situation
Used to test/silence the unit Test/Silence Button
Operating Features
Light Indicator
Power/Alarm LED flashes
Red
rapidly
Red
LED flashes
Power/Alarm LED flashes
Red
once every minute
Power/Alarm LED flashes
Red
once every minute
Sound Emitted
Repeating 4 beeps, pause
3 chirps every minute
1 chirp every minute
Silent
What This Means
Dangerous levels of CO has been detected
Malfunction/End of Life
Low Battery
Normal Operating Mode
Required Action
Follow Emergency Procedures
Replace the Alarm
Replace Batteries
None
Page 46 of 51
BRK
Contact Details
Telephone
Website
Main Features
Feature
Power LED (
Green
)
Fault LED (
Yellow
)
Alarm LED (
Red
)
Test/Reset Button
Operating Features
Light Indicator
Power LED flashes
Red
Off
Off
Fault LED is on
Yellow
Fault LED flashes
Yellow
Power LED is on
Green
+44 (0) 1452 877 570 [email protected] www.brkelectronics.eu
Function
Indicates that the unit is receiving power and is fully operational
Indicates low battery/fault/end of life
Indicates an emergency situation
Used to test/reset/silence the unit
Sound Emitted
Repeating 4 beeps, pause
Repeating 4 beeps, pause
3 short beeps every minute
2 short beeps every minute
Single beep every minute
Silent
What This Means
Dangerous levels of CO has been detected
Dangerous levels of CO has been detected at an interconnected alarm
End of Life
Fault
Low Battery
Normal Operating Mode
CO850
Required Action
Follow Emergency Procedures
Follow Emergency Procedures
Replace the Alarm
Replace the Alarm
Replace the Alarm
None
Page 47 of 51
NEST PROTECT
Contact Details
Telephone
Website
Main Features
+44 (0) 8081 692 307 (Support line – Mon-Fri from 07:00 to 19:00 –
Sat-Sun from 09:00 to 17:00) https://nest.com/uk/support/email-us/ https://nest.com/uk/support/smoke-co-alarm/
Feature
Green Light Indicator
Light Ring (
Blue
)
Light Ring (
Yellow
)
Light Ring (
Red
)
White
Light
Nest Button
Function
Indicates that the unit is receiving AC power and is fully operational
Indicates that the unit is in testing mode
Indicates a build-up of CO/Smoke, low battery and that the alarm has been hushed
Indicates an emergency CO/Smoke situation and that the alarm has been hushed
Pathlight in darkness
Used to test/silence the unit
Operating Features – Part 1 of 3
Light Indicator
Light pulses
Red
Light pulses
Red
Sound Emitted
“Emergency, there’s carbon monoxide in (room name). Move to fresh air now.”
“Emergency, there’s smoke in
(room name).”
What This Means
The carbon monoxide in the room has reached emergency levels
The smoke in the room has reached emergency levels
Page 1 of 2
Follow Emergency Procedures
Required Action
Follow Emergency Procedures
Page 48 of 51
NEST
Operating Features – Part 2 of 3
Light Indicator
Light pulses
Red
Light pulses
Red
Light pulses
Yellow
Light pulses
Yellow
Light pulses
Yellow
or
Red
None
None
Sound Emitted
“Emergency, there’s carbon monoxide in (room name). Move to fresh air now.”
“Emergency, there’s smoke in
(room name).”
“Heads-up, there’s carbon monoxide in the (room name). The alarm may sound.”
“Heads-up, there’s smoke in the
(room name). The alarm may sound.”
“Smoke Alarm has been hushed,” or “Carbon Monoxide Alarm has been hushed.”
Voice: “Nest product has expired.
Replace it now.”
Horn: Two chirps every 60 seconds
Voice: “The sensors have failed in the (room name), replace nest protect now.”
Horn: Single chirp every 60 seconds
PROTECT
What This Means
The carbon monoxide in the room has reached emergency levels
The smoke in the room has reached emergency levels
Carbon monoxide levels are rising.
This heads-up will occur if carbon monoxide levels stay at 70ppm for
60-240 minutes.”
Smoke levels are rising
You’ve hushed an alert
End of Life
Malfunction
Page 2 of 2
Required Action
Follow Emergency Procedures
Call the Emergency Services
Follow Emergency Procedures
Follow Emergency Procedures
Follow Emergency Procedures
Replace the Alarm
Clean with compressed air. If the problem persists, replace it
Page 49 of 51
NEST
Operating Features – Part 3 of 3
Light Indicator
Light pulses
Yellow
Sound Emitted
Voice: “The battery is very low in the (room name). Replace the battery now.”
Horn: Single chirp every 60 seconds
PROTECT
What This Means
Batteries have been depleted
Page 3 of 3
Required Action
Replace Batteries
Page 50 of 51
Light pulses
Blue
light rotating
White Light
Green
Yellow
Light is on
Green
Light pulses once after lights have been switched off at night
“The battery is low in the (room name). Replace the battery soon.”
“Ready, press to test.”
Silent
Silent
Silent
Low battery
To setup or run a manual test
Pathway lights your way as you pass under it
The unit has tested its sensors and batteries to confirm they are working correctly
The product is connected to AC power and is fully operational
Replace Batteries
Press the Nest button. Nest Protect will walk you through next steps.
None
None
None
Page 51 of 51