Analog Multimeter
AM-10
• Pocket Size - Very Economical
• 6 Functions, 10 Ranges
• ±4% Basic DC Accuracy
• 2" Mirrored Scale
• 2KΩ/V AC & DC Input Sensitivity
• Fuse and Diode Protection
• DC Current
• Resistance
• Decibels
• Battery Test
• 90-Day Limited Warranty
Test Leads (ML-10) and Operating Instructions Included
SPECIFICATIONS:
General
Front/Side Controls: Range selector switch,
“0” Ω adjustment
Movement: 90° arc, 200µA full scale
Scales (5): One scale for OHMS, 2 scales for
AC/DC, one scale for dB and Battery test
Scale Length: 2"
Operating Position: Horizontal or vertical
Power: 1.5V AA battery (not included)
Movement and Indicator Protection:
Diode and Fuse (0.5A, 250V)
Dimensions, Weight: 2.4" wide x 3.5" long x
1.1" thick (60mm x 89mm x 29mm),
net weight 4oz. (113g)
DC Voltage
AC Voltage
Decibels
Ranges: 0-15, 150, 500V
Input Impedance: 2kΩ per Volt
Rated Accuracy: ±4% of full scale
Ranges: 0-15, 150, 500V
Input Impedance: 2kΩ per Volt
Rated Accuracy: ±5% of full scale
Ranges:
-20dB to +26dB on 15V AC range
0dB to +46dB on 150V AC range
10dB to +56dB on 500V AC range
DC Current
Resistance
Ranges: 0-150mA
Rated Accuracy: ±4% of full scale
Ranges:
R x 1K 0 - 1MΩ (full scale)
2
Battery Test
Ranges: 1.5V AA
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Analog Multimeter
AM-22
• General Purpose VOM
• 7 Functions, 20 Ranges
• ±4% DC Accuracy FS
• 4" Mirrored Scale
• 20KΩ/VDC, 8KΩ/VAC
Input Sensitivity
• Fuse and Diode Protection
• 10 Amp DC Range
• 1000 Volts AC/DC
• Continuity Buzzer
• Battery Test
• Tilt Stand
• Anti-Skid Pads
• 90-Day Limited Warranty
Test Leads (ML-375), Spare Fuse and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-300) - See Page 24
SPECIFICATIONS:
General
Front Panel Controls: Range selector switch
with power “OFF” position, 0 Ω adjust and
mechanical zero adjuster
Movement: 90° arc, 40µA full scale
Scales (6): One scale for OHMS, 3 scales for
AC/DC, one scale for dB and one scale for
battery test
Scale Length: 4"
Operating Position: Horizontal or vertical;
rubber pads to prevent slipping on moderate
horizontal or vertical slopes
Power: 1.5V AA (2) batteries (not included)
Movement and Indicator Protection:
Diode and Fuse (0.5A/250V)
Dimensions, Weight: 3.8" wide x 5.875" long x
1.5" thick (97 mm x149 mm x 38 mm),
net weight 8.2oz. (231g)
DC Voltage
Resistance
Continuity Test
Ranges: 0-2.5, 10, 50, 250, 1000V
Input Impedance: 20kΩ per Volt
Rated Accuracy: ±4% of full scale
Ranges:
Rx1
0 - 10KΩ
R x 10
0 - 100KΩ
R x 1K
0 - 10MΩ
Rated Accuracy: ±4% of arc
Buzzer Response: <100Ω
Response Time: Instant
DC Current
Ranges: 0-5m, 50m, 500m, 10A
Rated Accuracy: ±4% of full scale
Battery Test
Ranges: 1.5V, 9V
Decibels
Ranges:
-8dB to +22dB on 10V AC range
+6dB to +36dB on 50V AC range
+20dB to +50dB on 250V AC range
+32dB to +62dB on 1000V AC range
AC Voltage
Ranges: 0-10, 50, 250, 1000V
Input Impedance: 8kΩ per Volt
Rated Accuracy: ±5% of full scale
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
3
Analog Multimeter
AM-30
• Our Top Of The Line Analog Meter
• Full Function • Temperature Measurement
• 3% DC Accuracy FS
• 5" Mirrored Scale
• 30KΩ/V DC, 10KΩ/V AC
Input Sensitivity
• Fuse and Diode Protection
• 10 Amp DC Range
• 1000 Volts AC/DC
• Transistor Test
• Battery Test
• Continuity Buzzer
• Tilt Stand/Carrying Handle
• 90-Day Limited Warranty
Test Leads (ML-43), Temperature Probe (TC-30),
Fuse and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-30) - See Page 24
SPECIFICATIONS:
General
Front Panel Controls: Range selector
switch with “OFF” position, 0Ω adjust/
temperature calibration, 0Ω calibration switch
Movement: 90° arc, 25µA movement
Scales (8): One scale for OHMS, three scales
for AC/DC, one scale for dB, two scales for
temperature, one scale for battery test
Scale Length: 5"
Operating Position: Horizontal or vertical;
rubber pads to prevent slipping on moderate
horizontal slopes
Power: 9V (NEDA 1604) and
1.5V AA (2) batteries (not included)
Movement and Indicator Protection:
Fuse (0.5A, 250V)
Operating Temperature: 18°C to 25°C
for rated accuracy
Dimensions, Weight: 4.8" wide x 6.9" long x
1.9" thick (127mm x 175mm x 48mm),
net weight 14oz. (422g)
DC Voltage
AC Voltage
Decibels
Ranges: 0-0.6, 3, 12, 60, 300, 1000V
Input Impedance: 30kΩ per Volt
Rated Accuracy: ±3% of full scale
Ranges: 0-12, 30, 120, 300, 1000V
Input Impedance: 10kΩ per Volt
Rated Accuracy: ±4% of full scale
DC Current
Resistance
Ranges: 120µ, 13m, 30m, 300m, 10A
Rated Accuracy: ±3% of full scale
Ranges:
Rx1
0-5kΩ
R x 100 0-500kΩ
R x 1k
0-5MΩ
R x 10k 0-50MΩ
Rated Accuracy: 3° arc
Ranges:
-10dB to +24dB on 12V AC range
-2dB to +32dB
8dB to +44dB
20dB to +52dB
30dB to +62dB
0dB referenced to 1 milliwatt at 600Ω
Temperature
Ranges: -50°C to +260°C (-60°F to +400°F)
Battery Test
Ranges: 1.5V AA, 9V
4
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Analog Multimeter
FET-43
• Very High Input Impedance
• Excellent Trouble Shooting Tool
• 5 Functions, 43 Ranges
• Polarity Reversing Switch *
• Zero Center Scale
Adjustment
• Low Battery Indicator
• Metal Tilt Stand
• 1-Year Limited Warranty
• 4.5" Meter Scale
• ±2.5% DC accuracy FS
• 10MΩ DC, 1MΩ AC
Input Resistance
• FET Input
• Jeweled Meter Movement
• Overload Protection †
Battery, Test Leads (ML-43) and Operating Instructions Included
SPECIFICATIONS:
General
Front Panel Controls: Range selector switch,
power on-off switch, with operational LED,
polarity reverse switch, "0" Ω ADJ,
Center "0" ADJ
Movement: Jeweled pivots, 90° arc,
44µA full scale
Scales (9): Ω DC V•A, AC RMS, AC peak to peak
(2), ±DC V•A (center null), AC 12 A,
DC 0.1µA, dB
Scale Length: 4.5"
*Polarity Reverse Switch: DC and Ω ranges
(Reverses meter movement only. Does not
reverse test lead polarity.)
Operating Position: Horizontal or
vertical, rubber pads to prevent
slipping on moderate slopes
Power: 1.5V AA (2) and
9V (NEDA 1604) batteries
Movement and Indicator Protection: Double
FET protection and fuse (2A/250V)
Operating Temperature: 25°C (75°F) rated
accuracy, less than 4% additional error over the
range of -4°C (25°F) to 50°C (130°F)
Dimensions, Weight: 5" wide x 6.75" long x
2" thick (125mm x 170mm x50mm),
net weight 17oz. (480g)
DC Voltage
AC Voltage
AC Current
Ranges: 0-0.3, 1.2, 3.0, 120, 300, 1200V,
0-±1.5, 0.6, 6, 15, 60, 150, 600V at Center 0
Input Impedance: Approx. 10MΩ, 3MΩ on
300 mV range
Rated Accuracy: ±2.5% DC and ±3.5% AC of
full scale on all ranges
Ranges: RMS 0-3, 12, 30, 120, 300, 1200V,
peak to peak, 0-8.4, 33, 84, 330, 840,
3300RMS, 1200V (peak to peak 3300V) on
separate jack
Input Impedance: Approx. 1MΩ, 800pF;
2.5MΩ on 3V range
Rated Accuracy:
50Hz - 5MHz ±3%
30Hz - 10MHz ±1dB sine wave
30Hz - 1MHz ±1dB rectangular wave at
3V range only
30Hz - 3MHz ±5% sine wave
30Hz - 120MHz ±5% rectangular on all other
ranges except 3V
dB: -10dB - +63dB on AC ranges
Ranges: 0-12A, within ± 3.5% full scale. DC,
AC,12 Amp range on separate jack
DC Current
Ranges: 0-0.1µA, 0.3, 3, 30, 300mA, 12A
Potential Drop: 300mV
Rated Accuracy: Within ±2.5% full scale on
all ranges
Resistance
Ranges:
Rx1
0 - 1KΩ (Center 10)
R x 10
0 - 10KΩ (Center 100Ω)
R x 100 0 - 100KΩ (Center 1KΩ)
R x 1K
0 - 1MΩ (Center 10KΩ)
R x 10K 0 - 10MΩ (Center 100KΩ)
R x 1M
0 - 1000MΩ (Center 10MΩ)
Accuracy: ±2.5° of arc
†
Does not apply to 12 Amp range. Damage to
meter or injury to operator can occur if voltage
or excessive current is applied to 12 Amp. input.
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
5
Pocket Digital Multimeter
DM-15
Use For: • Home • Office • Factory
• Car
• Boat • School
• Autoranging
• Auto Power OFF
• Bar Graph
• 3 1/2 Digit LCD, 0.35" H
• 3200 Count
• 10MΩ Input Z
• Data Hold
• Range Hold
• Diode Test
• Audible Continuity Test
• 32MΩ FS
• Overload Protection
• 1-Year Limited Warranty
Batteries, Test Leads, Carrying Case and Operating Instructions Included
SPECIFICATIONS:
General
Display: 3.5 Digit LCD, 0.35" high, with
polarity indicator
Overrange Indication: “OL” is displayed
Auto Power Off: Approx. 10 min. after mode
or function change
Measurement Rate: 2 times per second
Operating Environment: 0°C to 40°C, <70%
relative humidity
Storage Environment:
-20°C to 60°C,
<80% relative humidity
Power: 1.5V button-type
batteries (2) IEC LR-44, NEDA 1166A
Low Battery Indicator: "B" is displayed.
Dimensions, Weight: 2.2" wide x 4.4" long x
.41" thick (56mm x 111.5mm x 10.5mm),
net weight 3oz. (86g)
DC Voltage
AC Voltage
Resistance
Range
Resolution Accuracy
320mV 100µV
±2% of rdg ±2D
3.2V
1mV
±1% of rdg ±2D
32V
10mV
±2% of rdg ±2D
320V
100mV
±2% of rdg ±2D
450V
1V
±2% of rdg ±2D
Input Impedance: mV = >1000MΩ;
3.2V = 11MΩ. 10MΩ all other ranges
Maximum Input: 450V DC
Range
Resolution Accuracy
3.2V
1mV
±3% of rdg ±5D
32V
10mV
±3% of rdg ±5D
320V
100mV
±3% of rdg ±5D
Input Impedance: 3.2V = 11MΩ, 10MΩ all
other ranges
Maximum Input: 320V AC rms
Frequency Range: 50/60Hz
Range
Resolution Accuracy
320Ω
100mΩ
±2% of rdg ±4D
3.2KΩ
1Ω
±2% of rdg ±2D
32KΩ
10Ω
±2% of rdg ±2D
320KΩ 100Ω
±2% of rdg ±2D
3.2MΩ 1KΩ
±5% of rdg ±5D
32MΩ
10KΩ
±10% of rdg ±2D
Input Protection: 450V DC or 320 AC rms
Continuity Test (Audible)
Resistance Range: 320Ω
Beeper Response: <20Ω
Diode Test
Voltage: 3.2V @ 0.6mA
6
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Multimeter
DM-21
• Low Cost General Purpose
• Low Power Ω
• Overload Protection
• RF Shielded
• Polarity Indicator
• Low Battery Indicator
• Tilt Stand
• 1-Year Limited Warranty
• Transistor hFE
• Diode Test
• LED Test
• Square Wave Generator
• 7 Functions, 11 Ranges
• 0.8% Basic DC Accuracy
• 3 1/2 Digit LCD, 0.55" H
Battery, Test Leads (ML-375) and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-50) - See Page 24
SPECIFICATIONS:
General
Display: 3 1/2 Digit LCD, 0.55" high,
with polarity
Overrange Indication: “1” or “–1” is displayed.
Measurement Rate: 2.5 times per second
Operating Environment: 0°C to 50°C, <70%
relative humidity
Storage Environment: -20°C to 60°C, <80%
relative humidity with battery removed
Power: 9V carbon zinc battery (NEDA 1604)
Battery Life: 150 hours typical
with carbon zinc cells
Low Battery Indicator: Symbol is displayed
Dimensions, Weight: 2.8" wide x 6" long x 1.5"
thick (70mm x 151mm x 38mm),
net weight 7oz. (200g)
DC Voltage
Resistance
LED Test
Range
Resolution Accuracy
2V
1mV
±0.8% of rdg ±1D
20V
10mV
±0.8% of rdg ±1D
200V
100mV
±0.8% of rdg ±1D
600V
1V
±0.8% of rdg ±1D
Input Impedance: 1MΩ on all ranges.
Maximum Input: 600V DC or 500AC rms.
Range
Resolution Accuracy
200Ω
0.1Ω
±1.5% of rdg ±3D
2KΩ
1Ω
±1.5% of rdg ±3D
20KΩ
10Ω
±1.5% of rdg ±3D
200KΩ 100Ω
±1.5% of rdg ±3D
2MΩ
1KΩ
±1.5% of rdg ±3D
Overload Protection: 500V DC or 350AC rms
Voltage: <3.5V @ 10mA ±0.6mA
AC Voltage
Transistor hFE Test (PNP, NPN)
Range
Resolution Accuracy
200V
100mV
± 1.5% of rdg ±4D
500V
1V
± 1.5% of rdg ±4D
Input Impedance: 450KΩ on all ranges.
Maximum Input: 600V DC or 500AC rms.
Frequency Range: 50Hz - 500Hz.
Test Condition: 10µA Base Current @ <3.5V
hFE Range: 0 - 1000
Generator
Waveform: Square
Frequency: 50Hz approx
Output: ±3 to -0.5V DC, 50% Duty Cycle
Impedance: 120KΩ
Diode Test
Voltage: <3.5V @ 1mA ±0.6mA
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
7
Digital Multimeter
DM-38A
• Multifunction DMM • Heavy Duty
• 3 3/4 Digit, 0.5" H • Peak Data Hold
• Frequency Counter
• Capacitance Test
• Logic Detector
• 20A AC/DC
• 0.5% Basic DC Accuracy
• 40MΩ Full Scale
• Transistor hFE Test
• Diode Test
• Audible Continuity Test
• 20MΩ Input Z
• Overload Protection
• RF Shielded
• Lo Power Ohms
• Tilt Stand
• Polarity Indicator
• Overrange Indicator
• Low Battery Indicator
• 1-Year Limited Warranty
Battery, Test Leads and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-300) - See Page 24
SPECIFICATIONS:
General
Display: 3 3/4 Digit LCD, 0.5" high, with polarity
indicator (4,000 count)
Overrange Indication: “OL” is displayed
Measurement Rate: 3 times per second
Operating Environment: 0°C to 50°C, <70%
relative humidity
Storage Environment: -20°C to 60°C, <80%
relative humidity with battery removed
Power: 9V carbon zinc battery (NEDA 1604)
Battery Life: 150 hours typical with carbon
zinc cells
Low Battery Indicator: Display indicates “B”
Dimensions, Weight: 3.3" wide x 6.3" long x 1"
thick (84mm x 160mm x 25mm),
net weight 9oz. (250g)
Peak Data Hold: When the Peak Hold function is
engaged, the maximum reading is shown on the
display until a higher reading is recorded or
power to the meter is removed
DC Voltage
AC Current
Frequency Measurement
Range
Resolution Accuracy
400mV 100µV
±0.5% of rdg ±1D
4V
1mV
±0.5% of rdg ±1D
40V
10mV
±0.5% of rdg ±1D
400V
100mV
±0.5% of rdg ±1D
1000V
1V
±0.5% of rdg ±1D
Input Impedance: 20MΩ on all ranges
Overload Protection: 500V DC/350V AC for 15
sec. on 400mV range; 1,100V DC/800V AC on
all other ranges
Range
Resolution Accuracy
40mA
10µA
±1.2% of rdg ±4D
400mA 100µA
±1.2% of rdg ±4D
20A
10mA
±2% of rdg ±4D
Overload Protection: mA input, 0.8A/250V fuse;
20A input (unfused), up to 20A for 15 seconds
Range: 4K to 4MHz (Autorange)
Accuracy: ± 1% rdg ± 2D
Input Sensitivity: 50mV rms
Overload Protection: 500V DC/AC
Resistance
Logic Type: TTL
Input Impedance: 120KΩ ±10K
Logic Thresholds
Logic 1: 2.4V, ±0.2V
Logic 0: 0.7V, ±0.2V
Frequency Response: 20MHz
Detestable Pulse Width: 25ns, min.
Overload Protection: 50V DC/AC
DC Current
Range
Resolution Accuracy
40mA
10µA
±1% of rdg ±1D
400mA 100µA
±1% of rdg ±1D
20A
10mA
±2% of rdg ±3D
Overload Protection: mA input 0.8A/250V fuse;
20A input (unfused), up to 20A for 15 seconds
AC Voltage
Range
Resolution Accuracy
400mV 100µV
±1% of rdg ±4D
4V
1mV
±1% of rdg ±4D
40V
10mV
±1% of rdg ±4D
400V
100mV
±1% of rdg ±4D
750V
1V
±1.5% of rdg ±4D
Input Impedance: 20MΩ on all ranges
Overload Protection: 500V DC/350V AC for
15 sec. on 400mV range; 1,100V DC/800V AC
on all other ranges
Frequency Range: 50 - 500Hz
8
Range
Resolution Accuracy
400Ω
0.1Ω
±1% of rdg ±3D
4KΩ
1Ω
±0.8% of rdg ±1D
40KΩ
10Ω
±0.8% of rdg ±1D
400KΩ 100Ω
±0.8% of rdg ±1D
4MΩ
1KΩ
±0.8% of rdg ±1D
40MΩ
10KΩ
±3% of rdg ±3D
400MΩ 1MΩ
±5% of rdg -10D, +4D
Overload Protection: 500V DC/AC, 10 seconds
Capacitance
Range
Resolution
4nF
1pF
40nF
10pF
400nF
100pF
4µF
1nF
40µF
10nF
Test Frequency: 400Hz
Test Voltage: 50mV
Accuracy
±3% of rdg ±10D
±3% of rdg ±10D
±3% of rdg ±10D
±3% of rdg ±10D
±3% of rdg ±10D
Logic Measurement
Continuity Test
Resistance Range: 400Ω
Beeper Response: <50Ω
Response Time: <100mSec
Transistor hFE Test (PNP, NPN)
Test Condition: 10µA Base Current @ 2.8V
hFE Range: 0 - 1000
Diode Test
Voltage: 3.2V @ 1.6mA Max
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Multimeter
DM-50
• Low Cost-Multipurpose
• 9 Functions, 20 Ranges
• Frequency Counter
• Transistor hFE
• Battery Tester
• Diode Test
• 20MΩ FS
• 10A DC
• 0.5% Basic DC Accuracy
• 3 1/2 Digit LCD, 0.55" H
• Audible Continuity Test
• 10MΩ Input Z
• Low Power Ω
• Overload Protection
• RF Shielded
• Tilt Stand
• 1-Year Limited Warranty
Battery, Test Leads (ML-375), Spare Fuse and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-50) - See Page 24
SPECIFICATIONS:
General
Display: 3 1/2 Digit LCD, 0.55" high,
with polarity
Overrange Indication: “OL” is displayed
Measurement Rate: 2.5 times per second
Operating Environment: 0°C to 50°C, <70%
relative humidity
Storage Environment: -20°C to 60°C, <80%
relative humidity with battery removed
Power: 9V carbon zinc battery (NEDA 1604)
Battery Life: 150 hours typical with carbon
zinc cells
Low Battery Indicator: Symbol is displayed.
Dimensions, Weight: 2.8" wide x 6" long x 1.5"
thick (70mm x 151mm x 38mm),
net weight 7oz. (200g)
DC Voltage
AC Voltage
Frequency Measurement
Range
Resolution Accuracy
200mV 100µV
±0.5% of rdg ±1D
2V
1mV
±0.5% of rdg ±1D
20V
10mV
±0.5% of rdg ±1D
200V
100mV
±0.5% of rdg ±1D
600V
1V
±0.5% of rdg ±1D
Input Impedance: 10MΩ on all ranges
Maximum Input: 600V DC or AC rms
Range
Resolution Accuracy
200V
100mV
±1.5% of rdg ±4D
600V
1V
±1.5% of rdg ±4D
Input Impedance: 4.5MΩ on all ranges
Maximum Input: 600V DC or AC rms
Frequency Range: 50Hz - 500Hz
Range: 2kHz - 15MHz (Autorange)
Accuracy: ± 0.1% rdg ± 1D
Input Sensitivity: Trig Lo: 1 Vrms; Trig Hi: 2 Vrms
Overload Protection: 500V DC or 500AC rms
DC Current
1.5V (Load Current Approximately 150mA)
9V (Load Current Approximately 6mA)
Range
Resolution Accuracy
2mA
1µA
±1% of rdg ±1D
20mA
10µA
±1% of rdg ±1D
200mA 100mA
±1% of rdg ±1D
10A
10mA
±3% of rdg ±1D
Overload Protection: mA input, 0.5A/250V fuse;
10A input 10/600V fuse
Battery Tester
Resistance
Range
Resolution Accuracy
200Ω
0.1Ω
±0.8% of rdg ±3D
2KΩ
1Ω
±0.8% of rdg ±1D
20KΩ
10Ω
±0.8% of rdg ±1D
200KΩ 100Ω
±0.8% of rdg ±1D
2000KΩ 1KΩ
±0.8% of rdg ±1D
20MΩ
10KΩ
±3% of rdg ±3D
Overload Protection: 500V DC or 350AC rms
Continuity Test (Audible)
Resistance Range: 2KΩ
Beeper Response: <30Ω
Transistor hFE Test (PNP, NPN)
Test Condition: 10µA Base Current @ 3.5V
hFE Range: 0 - 1000
Diode Test
Voltage: 2V @ 1.6mA Max
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
9
Digital Multimeter
DM-59
• Perfect For Workshop and School
• 10 Functions, 30 Ranges
• Frequency Counter
• hFE
• Capacitance
• Diode Test
• 20MΩ FS
• 10A AC/DC
• 0.5% Basic DC Accuracy
• 3 1/2 Digit LCD, 0.55" H
• Audible Continuity Test
• 10MΩ Input Z
• Overload Protection
• RF Shielded
• Tilt Stand
• 1-Year Limited Warranty
Battery, Test Leads (ML-375), Spare Fuse and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-50) - See Page 24
SPECIFICATIONS:
General
Display: 3 1/2 Digit LCD, 0.55" high, with
polarity
Overrange Indication: “OL” is displayed
Measurement Rate: 2.5 times per second
Operating Environment: 0°C to 50°C, <70%
relative humidity
Storage Environment: -20°C to 60°C, <80%
relative humidity with battery removed
Power: 9V carbon zinc battery (NEDA 1604)
Battery Life: 150 hours typical with carbon
zinc cells
Low Battery Indicator: Symbol is displayed
Dimensions, Weight: 2.8" wide x 6" long x 1.5"
thick (70mm x 151mm x 38mm)
net weight 7oz. (200g)
DC Voltage
AC Current
Frequency Measurement
Range
Resolution Accuracy
200mV 100µV
±0.5% of rdg ±1D
2V
1mV
±0.5% of rdg ± 1D
20V
10mV
±0.5% of rdg ±1D
200V
100mV
±0.5% of rdg ±1D
600V
1V
±0.5% of rdg ±1D
Input Impedance: 10MΩ on all ranges
Maximum Input: 600V DC or AC rms
Range
Resolution Accuracy
2mA
1µA
±2.0% of rdg ±4D
20mA
10µA
±2.0% of rdg ±4D
200mA 100mA
±2.0% of rdg ±4D
10A
10mA
±3.5% of rdg ±4D
Overload Protection: mA input, 0.5A/250V fuse;
10A input 10A/250 fuse
Range: 2kHz - 15MHz (Autorange)
Accuracy: ±0.1% rdg ±1D
Input Sensitivity: Trig Lo: 1 Vrms; Trig Hi: 2 Vrms
Overload Protection: 500V DC or AC rms
Resistance Range: 200Ω
Beeper Response: <40Ω
Resistance
DC Current
Range
Resolution Accuracy
2mA
1µA
±1.0% of rdg ±1D
20mA
10µA
±1.0% of rdg ±1D
200mA 100mA
±1.0% of rdg ±1D
10A
10mA
±3.0% of rdg ±1D
Overload Protection: mA input, 0.5A/250V fuse;
10A input 10A/600V fuse
Range
Resolution Accuracy
200Ω
0.1Ω
±0.8% of rdg ±3D
2KΩ
1Ω
±0.8% of rdg ±1D
20KΩ
10Ω
±0.8% of rdg ±1D
200KΩ 100Ω
±0.8% of rdg ±1D
2000KΩ 1KΩ
±0.8% of rdg ±1D
20MΩ
10KΩ
±3% of rdg ±3D
Overload Protection: 500V DC or AC rms
AC Voltage
Capacitance
Range
Resolution Accuracy
200mV 100µV
±1.0% of rdg ±4D
2V
1mV
±1.0% of rdg ±4D
20V
10mV
±1.0% of rdg ±4D
200V
100mV
±1.0% of rdg ±4D
600V
1V
±1.9% of rdg ±4D
Input Impedance: 10MΩ on all ranges
Maximum Input: 600V DC or AC rms
Frequency Range: 50Hz - 500Hz
Range
Resolution
2000pF 1pF
20nF
10pF
200nF
100pF
2µF
1nF
20µF
10nF
Test Frequency: 2.5Hz
Test Voltage: 3V
10
Continuity Test (Audible)
Transistor hFE Test (PNP, NPN)
Test Condition: 10µA Base Current @ <3.5V
hFE Range: 0 - 1000
Diode Test
Voltage: 2V @ 1.6mA Max
Accuracy
±2.0% of rdg ±10D
±2.0% of rdg ±10D
±2.0% of rdg ±10D
±2.0% of rdg ±10D
±2.0% of rdg ±10D
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Multimeter
DM-75
• Low Cost
• Full Function General Purpose
• Rotary Range Switch
• Diode Test
• 0.7% Basic DC Accuracy
• 3 1/2 Digit LCD, 0.5" H
• 10A DC
• 10MΩ Input Impedance, DC
• Overload Protection
• Pocket Size
• 90-Day Limited Warranty
Battery, Test Leads and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-50) - See Page 24
SPECIFICATIONS:
General
Display: 3 1/2 Digit LCD, 0.5" high, with
polarity indicator
Overrange Indication: 3 least significant
digits blanked
Operating Environment: 0°C to 50°C, <80%
relative humidity
Storage Environment: -15°C to 50°C
Power: 9V alkaline or carbon zinc battery
Battery Life: 100 hours typical with
carbon zinc cells, 200 hours typical
with alkaline cells
Dimensions, Weight: 2.8" wide x
5" long x 1" thick (71mm x 127mm x
25.4mm), net weight 6.1oz. (173g)
DC Voltage
AC Voltage
Range
Resolution Accuracy
200mV 0.1mV
±0.7% of rdg ±4D
2000mV 1mV
±0.7% of rdg ±2D
20V
10mV
±0.7% of rdg ±2D
200V
100mV
±0.7% of rdg ±2D
1000V
1V
±0.7% of rdg ±2D
Input Impedance: 10MΩ on all ranges
Range
Resolution Accuracy
200V
100mV
±1.2% of rdg ±10D
750V
1V
±1.2% of rdg ±10D
Overload Protection: 750V rms
Frequency Range: 45Hz - 450Hz
DC Current
Range
200Ω
2000Ω
20KΩ
200KΩ
2000KΩ
Range
Resolution Accuracy
200µA
0.1µA
± 1% of rdg ± 2D
2000µA 1µA
± 1% of rdg ± 2D
20mA
10µA
± 1% of rdg ± 2D
200mA 100µA
± 1.2% of rdg ± 2D
2000mA 1mA
± 1.5% of rdg ± 2D
10A
10mA
± 1.5% of rdg ± 2D
Overload Protection: mA input, 2A/250V fuse;
10A input (unfused) up to 10A for 15 seconds
Resistance
Resolution
0.1Ω
1Ω
10Ω
100Ω
1KΩ
Accuracy
±0.7% of rdg ±2D
±0.7% of rdg ±2D
±0.7% of rdg ±2D
±0.7% of rdg ±2D
±1% of rdg ±2D
Diode Test
Voltage: 2.8V @ 1mA
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
11
Digital Multimeter
DM-78A
• Heavy Duty, Ideal For Plant/
Industrial Maintenance
• Water Resistant (O-Ring Seals)
• Withstands 5' Drop
• Protective Holster (MH-350)
• Large Display Window
• 3200 Count LCD, .55" H
• 65 Segment Analog Bar Graph
• 0.5% Basic DC Accuracy
• Auto Power Off
• 10MΩ Input Z
• “No Hand” Data Hold
• Input Warning Beeper*
• 20A AC/DC Fused
• Diode Test
• Instant Continuity Beeper
• Overload Protection
• 1-Year Limited Warranty
Batteries, Test Leads (ML-375), and Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-300) - See Page 24
SPECIFICATIONS:
General
Display: 3200 count LCD, 65 segment bar
graph, 0.55" high, with polarity
Auto Power Off: Approx. 10 min. after mode or
function change
Overrange Indication: “OL” is displayed
Operating Environment: 0°C to 50°C, <80%
relative humidity
Storage Environment: -20°C to 60°C, <80%
relative humidity with battery removed
Temperature Coefficient: (0°C to 18°C and
28°C to 50°C), less than 0.15 x applicable
accuracy specification per second
Measurement Rate: Digital 2 times
per second, analog 12 times per second
Power: 1.5V AAA (2) alkaline or carbon
zinc batteries
Battery Life: 1000 hours with alkaline cells
Low Battery Indicator: Symbol is displayed
Fuse: 1A 240/250V Fast
Dimensions, Weight: 3.3" wide x 6.9" long x
1.2" thick (84mm x 175mm x 31mm),
net weight 12oz. (340g)
DC Voltage
AC Voltage
Resistance
Range
Resolution Accuracy
300mV 0.1mV
±0.5% of rdg ±2D
3V
1mV
±0.5% of rdg ±2D
30V
10 mV
±0.5% of rdg ±2D
300V
100mV
±0.5% of rdg ±2D
1000V
1V
±0.5% of rdg ±2D
Input Impedance: 10MΩ
Overload Protection: 1100VpK (15 sec.)
Range
Resolution Accuracy
3V
1mV
±1.3% of rdg ±5D
30V
10mV
±1.3% of rdg ±5D
300V
100mV
±1.3% of rdg ±5D
750V
1V
±1.3% of rdg ±5D
Frequency Range: 3V on 40Hz - 300Hz;
40Hz - 500Hz all others
Input Impedance: 10MΩ on all ranges
Overload Protection: 770V AC RMS or 1100Vpk
(15 sec.)
Range
Resolution Accuracy
(Lo-Power Ω)
300Ω
0.1Ω
±1% of rdg ±4D
3KΩ
1Ω
±0.75% of rdg ±2D
30KΩ
10Ω
±0.75% of rdg ±2D
300KΩ 100Ω
±0.75% of rdg ±2D
3MΩ
1KΩ
±1.5% of rdg ±3D
30MΩ
10KΩ
±2.5% of rdg ±5D
Lo-Power Ω open circuit 1.3V
Overload Protection: 600VDC or 600V AC RMS
(10 sec. )
DC Current
Range
Resolution Accuracy
300µA
0.1µA
±1% of rdg ±2D
3mA
1µA
±1.2% of rdg ±2D
30mA
10µA
±1% of rdg ±2D
300mA 100µA
±1.2% of rdg ±2D
20A
10mA
±2% of rdg ±3D
Overload Protection: µA, mA = 1A 240/250V,
20A = 13A 240/250V (readings over 10A max.,
30 sec.)
Voltage Drop: 200mV on 300µA, 30mA ranges;
2V all others
12
AC Current
Range
Resolution Accuracy
300µA
0.1µA
±1.5% of rdg ±3D
3mA
1µA
±1.5% of rdg ±3D
30mA
10µA
±1.5% of rdg ±3D
300mA 100µA
±2% of rdg ±3D
20A
10mA
±2.5% of rdg ±5D
Frequency Range: 40Hz - 500Hz
Overload Protection: µA, mA = 1A 240/250V,
20A = 13A 240/250V (readings over 10A max.,
30 sec.)
Voltage Drop: 200mV on 300µA, 30mA ranges;
2V all others
Diode Test
Voltage: 3.3V @ 1.5mA max
Continuity Test
Beeper Response: <50Ω
Response Time: Instant
Delay Hold: Allows “No-Hand” data hold
operation
* Input Warning Beeper: Eliminates incorrect
test lead placement and selector switch settings
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Multimeter
DM-80
• Heavy Duty, Ideal For Plant/Industrial Maintenance
• Autoranging • 11 Functions, 39 Ranges
• 0.3% Basic DC Accuracy
• 42 Segment Bar Graph
• 4000 Count LCD
• Min./Max.
• Data Hold
• Memory
• Capacitance
• Frequency
• Temperature
• Diode Test
• Audible Continuity Test
• Overload Protection
• 1-Year Limited Warranty
Battery, Test Leads (ML-375), Thermocouple (TC-50P), Protective Holster and
Operating Instructions Included
OPTIONAL ACCESSORY - Carrying Case (MC-80) - See Page 24
SPECIFICATIONS:
General
Display: 3 3/4 Digit LCD with polarity indicator,
42 segment bar graph, .5" high
Auto Power Off: 30 minutes
Overrange Indication: Most significant
digit blinks
Operating Environment: 0°C to 40°C,
<80% relative humidity
Storage Environment: -20°C to 60°C,
<70% relative humidity
Measurement Rate: Digital 2 times per second,
bargraph 20 times per second, capacitance
1 time per second
Power: 9V alkaline or carbon zinc battery
(NEDA 1604)
Battery Life: 500 hours typical with alkaline cells
Fuse: 2A/250V
Dimensions, Weight: 3.25" wide x 7" long x
1.25" thick (82.6mm x 177.8mm x 31.8mm),
net weight 11.5oz. (326g)
DC Voltage
AC Current
Frequency Measurement
Range
Resolution Accuracy
400mV 0.1mV
±0.3% of rdg ±1D
4V
1mV
±0.3% of rdg ±1D
40V
10mV
±0.3% of rdg ±1D
400V
100mV
±0.3% of rdg ±1D
1000V
1V
±0.3% of rdg ±3D
Overload Protection: 1000V pk (10 sec.)
Range
Resolution Accuracy
4mA
0.001mA
±2% of rdg ±5D
40mA
0.01mA
±2% of rdg ±5D
400mA 0.1mA
±2% of rdg ±5D
2000mA 1mA
±2% of rdg ±5D
10A
0.01A
±2% of rdg ±5D
Frequency Range: 50Hz - 500Hz
Overload Protection: mA = 2A/250V,
10A = Unfused
Range
100Hz
1000Hz
10kHz
100kHz
1000kHz
DC Current
Range
Resolution Accuracy
4mA
0.001mA
±1.5% of rdg ±2D
40mA
0.01mA
±1.5% of rdg ±2D
400mA 0.1mA
±1.5% of rdg ±2D
4000mA 1mA
±1.5% of rdg ±2D
10A
0.01A
±2% of rdg ±2D
Overload Protection: mA = 2A/250V,
10A = Unfused
AC Voltage
Range
Resolution Accuracy
4V
1mV
±1.2% of rdg ±5D
40V
10mV
±1.2% of rdg ±5D
400V
100mV
±1.2% of rdg ±5D
750V
1V
±1.2% of rdg ±5D
Input Impedance: 10MΩ on all ranges
Overload Protection: 1000V pk (10 sec.)
Resistance
Range
Resolution Accuracy
400Ω
0.1Ω
±1% of rdg ±2D
4KΩ
1Ω
±0.7% of rdg ±2D
40KΩ
10Ω
±0.7% of rdg ±2D
400KΩ 100Ω
±0.7% of rdg ±2D
4MΩ
1KΩ
±0.7% of rdg ±2D
40MΩ
10KΩ
±2% of rdg ±5D
Overload Protection: 250V DC or peak AC,10 sec.
Accuracy
±1% of rdg ±10D
±1% of rdg ±10D
±1% of rdg ±10D
±1% of rdg ±10D
Not Specified
Temperature Measurement
Range: 0°F to 2000°F
Resolution: 1°F
Accuracy: 0°F to 225°F (±5° ±2D)
225°F to 2000°F (±3% of rdg)
Diode Test: 3.2V
Continuity Test (Audible)
Beeper Response: <40Ω
Response Time: Instantly
Capacitance
Range
4nF
40nF
400nF
4µF
40µF
Resolution
0.001nF
0.01nF
0.1nF
1nF
10nF
Accuracy
±5% of rdg ±2D
±5% of rdg ±2D
±5% of rdg ±2D
±5% of rdg ±2D
±5% of rdg ±2D
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Resolution
0.001Hz
0.1Hz
1Hz
10Hz
100Hz
13
Digital Multimeter
DM-500
• Our Top Of The Line DMM
• High Accuracy & Resolution - Affordable Price
• Perfect For Lab Use or Plant Maintenance
• Auto Ranging/True RMS
• Dual Display
• Analog Bar Graph
• 3 3/4 Digit LCD, 1.8" H
• 10 Location Memory
• Time Mode
• MIN, MAX, AVG and REL
• Capacitance/Inductance
• Temperature (C & F)
• Logic Detector
• Continuity/Diode Test
• Fused 20A Input
• Data Hold
• 2-Year Limited Warranty
Battery, Test Leads (ML-375), Thermocouple (TC-50P), Adapter (MA-500),
Carrying Case, Spare Fuse and Operating Instructions Included
OPTIONAL ACCESSORIES - Safety Holster with Probe Holders (MH-500),
Soft Carrying Case (MC-500) - See Page 24
SPECIFICATIONS:
General
Display: 3 3/4 Digit LCD, 1.8" high, 21 segment
bar graph
Overrange Indication: “OL” is displayed.
Operating Environment: 0°C to 50°C,
<80% relative humidity
Storage Environment: -40°C to 70°C,
<95%relative humidity with battery removed
Auto Power OFF: After 30 min. ±1 min. with no
key operation except for Hz, C or L
Power: 9V alkaline or carbon zinc battery
Battery Life: 60 hours typical with carbon zinc
cells, 120 hours typical with alkaline cells
Low Battery Indication: Below 6.9V ±0.5V
Dimensions, Weight: 3.46" wide x 7.83" long x
1.45" thick (88mm x 199mm x 37mm),
Net weight 14.5oz. (410g)
DC Voltage
AC Voltage
Resistance
Range
Resolution Accuracy
400mV 0.1mV
±0.3% of rdg ±2D
4V
0.001V
±0.5% of rdg ±2D
40V
0.01V
±0.5% of rdg ±2D
400V
0.1V
±0.5% of rdg ±2D
1000V
1V
±0.5% of rdg ±2D
Overload Protection: 250V rms, PTC on 400mV
range, 1000V rms on all other ranges
Input Impedance: 71GΩ on 400mV range,
10MΩ on all other ranges
Range
Resolution Accuracy
400mV 0.1mV
±1% of rdg ±3D
4V
0.001V
±1.5% of rdg ±5D
40V
0.01V
±1.5% of rdg ±5D
400V
0.1V
±1.5% of rdg ±5D
750V
1V
±1.5% of rdg ±5D
Input Impedance: >1GΩ on 400mV range,
10MΩ on all other ranges
Overload Protection: 250V rms, PTC on the
400mV range, 100V rms on all other ranges
Frequency Range: 50Hz to 1KHz on 400mV
range, 50Hz to 100Hz on the 4V range, 50Hz to
500Hz on all other ranges
Range
Resolution Accuracy
400Ω
0.1Ω
±0.5% of rdg ±2D
4KΩ
0.001KΩ
±0.5% of rdg ±2D
40KΩ
0.01KΩ
±0.5% of rdg ±2D
400KΩ 0.1KΩ
±0.5% of rdg ±2D
4MΩ
0.001MΩ ±1% of rdg ±2D
40MΩ
0.01MΩ
±1% of rdg ±2D
Overload Protection: 250V rms, PTC
DC Current
Range
Resolution Accuracy
400µA
0.1µA
± 1% of rdg ± 2D
400mA 0.1mA
± 1% of rdg ± 2D
20A
0.1A
± 1% of rdg ± 2D
Overload Protection: 250V rms, PTC on 400µA
range, 0.5A/250V fuse on 400µA range,
20A/250V fuse on 20A range
14
AC Current
Range
Resolution
400µA
0.1µA
400mA 0.1mA
20A
0.01A
Accuracy: ±1.5% of rdg ±3D @ 50Hz to
100Hz, ±3% of rdg ± 5D @ 100Hz to 1kHz
Overload Protection: Use DC current values
Frequency Measurement
Range
10kHz
100kHz
1MHz
10MHz
Continued on next page.
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Resolution
1Hz
10Hz
100Hz
1kHz
Accuracy
±0.01% of rdg ±1D
±0.01% of rdg ±1D
±0.01% of rdg ±1D
±0.01% of rdg ±1D
Digital Multimeter
DM-500
continued
SPECIFICATIONS:
Decibel
Frequency
Range dBm Range
4V
-25.74 to 14.25 30 to 200Hz
40V -5.74 to 8.24 20 to 1kHz
40V -5.74 to 8.24 1k to 2kHz
40V -5.74 to 8.24 2k to 5kHz
40V 8.24 to 34.25 30 to 5kHz
40V 8.24 to 34.25 5k to 10kHz
40V 8.24 to 34.25 10k to 20kHz
400V 31.76 to 54.25 30 to 20kHz
750V 51.76 to 59.71 30 to 20kHz
Input Impedance: 10MΩ
Resolution: 0.01dBm
Accuracy
±0.5dB
±0.5dB
±1dB
±2dB
±0.5dB
±1dB
±2dB
±0.5dB
±0.5dB
Logic Measurement
Logic Type: TTL
Range: Lo = <0.8V, Hi = >2V, Mid = 0.8V to 2V
Capacitance
Time
Range: 0 - 100µF
Resolution: 0.01µF
Accuracy: ±3% of rdg ±5D
Range: 1 sec. to 10 hours (presettable)
Resolution: 1 sec
Accuracy: ±0.2% of rdg ±1D
Diode
Temperature
Open Circuit Voltage: 3.3V max.
Test Current: 1mA
Range: -17°C to 1200°C (0°F to 2000°F)
Resolution 1°C (1°F)
Accuracy:
±3% of rdg ±5D from -20°C to 10°C
(0°F to 50°F)
±3 of rdg ±3D from 10°C to 350°C
(50°F to 662°F)
±5% of rdg ±3D from 350°C to 1200°C (662°F
to 2000°F)
Inductance
Range: 0 to 100H
Resolution: 0.01H
Accuracy: ±3% of rdg ±5D up to 20H
±5% of rdg ±5D up to 50H
±10% of rdg ±5D up to 100H
Signal Out
Frequency: 2048Hz, 4096Hz,
8192Hz Square Wave
Output Level: 4V p-p min.
Accuracy: ±0.01%
Output Impedance: 1.5kΩ
Continuity
Beeper Response: <100Ω
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
15
AC Clamp-On Current Adapter
CM-100
• Ideal For Plant/Industrial Maintenance
• Adds AC Clamp-On Current Measurement
Capability To Standard DMMs*
• 0-1000 Amps AC
• ±2.5% Basic Accuracy
0-800 A; 3.5% 800-1000A
• 1mV/1A Resolution
• 0-1V RMS AC Output
with ≥1mΩ Meters
• 2.1" Jaw Opening
• Works with Most DMMs
(Full Scale ≤1-2V AC)
• Small Size
• Light Weight
• Durable, High Impact
Plastic Case
• 90-Day Limited Warranty
Test Leads, Wrist Strap and Operating Instructions Included
SPECIFICATIONS:
General
Input: 0-1000A AC max.
Output: 0-1V AC RMS with ≥1MΩ meters
Resolution: 1mV/1A
Accuracy (50 Hz - 60 Hz):
0-800A
±2.5% of rdg ±4D
800-1000A
±3.0% of rdg ±4D
Operating Temperature: 0°C to +50°C
Storage Temperature: -20°C to +60°C
Dimensions, Weight: 3.4" wide x
7.25" long x 1" thick (86mm x 184mm x
25mm), net weight 7oz. (198g)
Output Jacks: Standard banana type
The ECG model CM-100 Adapter Jaw enables
clamp-on AC current measurements of up to
1000 amperes to be made with a conventional
digital multimeter.
* The CM-100 works with most popular brands
and models of DMMs. It requires a meter with
an AC voltage range ≤1-2V AC full scale and an
input impedance of 1.0mΩ or greater.
16
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Capacitance Meter
CX-920A
• A “Must” For Trouble Shooting and Circuit Design
• Measures To 20mF (20,000µF)
• Portable, Battery Operated
• 0.1pF to 20mF
(20,000µF), 9 Ranges
• 0.5% Basic Accuracy
• 3 1/2 Digit LCD, 0.55" H
• Zero Adjustment
• Input Protected
• Low Battery Indicator
• Overrange Indicator
• Rotary Range Switch
• Rugged Construction
• Tilt Stand
• 1-Year Limited Warranty
Battery, Test Leads (ML-920A), Spare Fuse and Operating Instructions Included
SPECIFICATIONS:
General
Display: 3 1/2 Digit LCD, 0.55" high
Overrange Indication: A "1" is displayed with
the 3 least significant digits blanked
Operating Environment: 0°C to 50°C,
<70% relative humidity
Storage Environment: -20°C to 60°C,
<80% relative humidity with battery removed
Temperature Coefficient: 0.1 x specified
accuracy per °C, which is only applicable for the
temperature range of <18°C or >28°C
Power: 9V alkaline or carbon zinc battery
(NEDA 1604)
Battery Life: 150 hours typical with carbon
zinc cells
Low Battery Indicator: Symbol is displayed
Dimensions, Weight: 2.8" wide x 6" long x 1.5"
thick (70mm x 151mm x 38mm),
net weight 7oz. (200g)
Capacitance
Test Voltage
Range
Resolution
Accuracy
200pF
0.1pF
±0.5% of rdg ±1D ±0.5pF
2000pF
1pF
±0.5% of rdg ±1D
20nF (.02µF)
10pF
±0.5% of rdg ±1D
200nF (.2µF)
100pF
±0.5% of rdg ±1D
2µF
1nF
±0.5% of rdg ±1D
20µF
10nF
±0.5% of rdg ±1D
200µF
0.1µF
±0.5% of rdg ±1D
2000µF
1µF
±2% of rdg ±1D
20mF (20,000µF) 10µF
±4% of rdg ±1D
Accuracy is based on an operating temperature of 23°C (73°F) at
relative humidity up to 75%
3.5V peak max., “+” input terminal voltage is always higher than
“–” input terminal
Overload Protection
100mA/250V, fast blow fuse
Zero Capacitance Adjustment Range
Approx. ±20pF
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
17
Battery Tester
BAT-15
Ideal For: • Home • Office • Workshop
• Very Economical
• 15 Measuring Ranges
• Pocket Size
• Moving Coil -90° Arc, 200µA FS Movement
• Easy To Read Scales
• Self Storing Test Leads
• High Impact ABS Plastic Case
Battery, Test Leads and Operating Instructions Included
SPECIFICATIONS:
General
Front Panel Controls: Function selector switch,
mechanical zero adjuster
Movement: Moving coil -90° arc, 200µA
full scale
Scales (3): Silver, mercury, all other batteries
Operating Position: Horizontal or vertical
Dimensions, Weight: 4.12" long x
2.5" wide x 1.2" thick (105mm x 64mm x
32mm), net weight 4.1oz. (116g)
Total Load
Ohm
Working Fine
Current (mA)
Max. Replace
Volts
Max. Good
Volts
1.5V Button
All Chemistries* 1.5V “AAA”
All Chemistries* 1.5V “AA”
All Chemistries* 1.5V “C”
All Chemistries* 1.5V “D”
750
75
37.5
10
5
2
20
40
150
300
1.05
1.05
1.05
1.05
1.05
1.65
1.65
1.65
1.65
1.65
3V Lithium
22.5V
12V
9V
6V Lantern
3,000
2,250
60
500
15
1
10
200
18
400
2.1
15.7
8.4
6.3
4.2
3.3
24.7
13.2
9.9
6.6
5.6-6.0V
4.0-4.5V
2.7-3.0V
1.6-1.7V
1.35-1.4V
1,200
900
600
1,500
292
5
5
5
1
5
3.8
2.86
1.91
1.08
1.05
6.0
4.5
3.0
1.7
1.65
Battery
1. Working Fine Currents (mA) are based on nominal battery voltage
2. Max. Replace Volts are 70% of nominal battery voltage
3. Max. Good Volts are 110% of nominal battery voltage
*
NOTICE
1.5V AAA, AA all chemistries: General purpose (carbon zinc)
1.5V C, all chemistries: Heavy-duty (zinc chloride)
1.5V D, all chemistries: Alkaline (alkaline manganese)
18
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Digital Infrared Thermometer
DIT-205
• Pen-style IR thermometer fits easily in a pocket or purse for
quick and easy surface temperature measurements
• Temperature Range: -27° to 428°F (-33° to 220°C)
• Accuracy: ±2% of reading or ±2°C
• 0.1° resolution for accurate readings
• Selectable temperature units F/C
• 1:1 Optics (distance-to-spot size ratio)
• Emissivity preset to 0.95
• LCD display
• Non-contact
• Does not use a laser beam
• Metal alloy case
• Lithium batteries (2 LR44 included
typically provide for 180 hours of
continuous operation)
• Low battery indication
• Automatic power OFF
after 15 seconds
• RoHS Compliant
• 1 Year Warranty
• Durable pocket clip
SPECIFICATIONS:
General
Measurement Range: -27° to 428°F
(-33° to 220°C)
Ambient Operating Range: 32° to 122°F
(0° to 50°C)
Storage Temperature Range: -4° to 149°F
(-20° to 65°C)
Where can I use
an infrared thermometer?
Kitchen:
• Temperatures of all cooking surfaces
• Microwaved foods
• Dishes in microwave heat differently
• Baby formula bottles
• Baby foods
• Teflon fry pans actually become
toxic at high temperatures
• Appliance performance:
freezer and oven temperature
• Dishwasher water temperatures
• Hot oil temperatures in deep fryers
• Cookie sheet temperature
• Crock pot accuracy
• Melting chocolate
• Candle making
• Home beer brewing
• Fondues: cheese, oil, chocolate
• Serving temperatures of beer and wine
• Pizza ovens
Safety:
• Child car seats
• Bath water: especially children and infants
• Check playground equipment:
slides and swings
• Beach sand
• Benches and chair temperatures
Accuracy: ±2% of reading or ±2°C
Resolution at -9.9°~199.9°C: 0.1° F or °C
Response Time (90%): 1 second
D:S: 1:1
Emissivity: Fixed 0.95
Update Frequency: 1.4Hz
Dimensions: 3.25 x 0.5 inches
Wave Length Response: 5-14um
Weight (with battery): 2 oz
Batteries: 2 LR44 (included)
Battery Life: 180hr (typical)
Health:
• Foot temperatures for diabetics
• Muscle tears and sprains
• Arthritic areas
• Horses: bad shoe, muscle tear, scar tissue
• Livestock breeding area temperatures
• Food serving quality at buffets
• Damp spots where mold and mildew grow
Outdoor uses:
• Verify BBQ surface temperatures
• Water temperatures in pools, spas
and hot tubs
• Lawns for heat stress and areas
sprinkler missed
• Outdoor fire pits and tool temperatures
• Small stoke engines: mowers, snow blowers
• Driveway temperature before
recoating surfaces
Around the home:
• Doors and windows for drafts
• Air conditioner air temperature
• Furnace registers
• Flue temperature in heating systems
• Ballasts in florescent lighting
• Dimmer switches for overheating
• Lightbulb before unscrewing
• Wood stoves flue temperature and ducts
• Fireplace logs (gas burn)
• Fuses and breakers for possible shorts
• Room temperatures
(scan walls for heat layers)
• Reptile cages and environment
• Aquarium water temperatures
• Air conditioning: supply and return registers
• Surface temperature before painting
Automotive, Hobby, Racing:
• Engine check - spark plugs - manifold
• Air conditioning and heating
• Radiator blockages
• Brake temperatures overheating
• Catalytic converters blockage
• Tire temperatures - under/over inflated
• Track temperatures match correct tires
• Engine temperatures in remote control
vehicles
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
19
Handheld Digital Thermometer
DT-205
• Perfect For - HVAC/Industrial Maintenance - Techs - Hobbyist
• Pocket Size - Light Weight • Built-In Retractable 3.5" Probe
• °C or °F Switchable
• ±1°C, ±2°F Accuracy
• Up to 0.1° Resolution
• 3.5 Digit LCD, 0.55" H
• Rugged Construction
• Low Battery Indicator
• Overrange Indicator
• 90 Day Limited Warranty
Battery, Carrying Case and Operating Instructions Included
DESCRIPTION:
The DT-205 is a pocket-sized Digital Thermometer with a built-in
thermocouple probe that retracts into the case. It possesses features of
more costly instruments such as switchable Fahrenheit and Celsius
scales, up to 0.1° resolution and a large easy-to-read 3 1/2 digit display.
Measurement range is -50°C to 150°C and -58°F to 302°F. Ruggedly
constructed and fast acting, the DT-205 is ideally suited for set up,
adjustment and monitoring heating and cooling systems plus checking
for heat loss.
SPECIFICATIONS:
General
Celsius
Display: 3 1/2 Digit LCD, 0.5" high.
Overrange Indication: A “1” or “–1” is displayed with the 3 least
significant digits blanked
Measurement Rate: 3 times per second
Operating Environment: 0°C to 35°C, <90% relative humidity,
35°C to 50°C <70% relative humidity
Storage Environment: -40°C to 60°C, with battery removed
Power: 9V alkaline or carbon zinc battery (NEDA 1604)
Battery Life: 300 hours typical with carbon zinc cells
Low Battery Indicator: Display indicates "Bat"
Dimensions, Weight: 1.8" wide x 5.6" long x 1.1" thick
(46mm x 142mm x 28mm) Net weight 5.6oz. (142g) with battery
Range
-50°C to 150°C
20
Resolution
0.1°C
Accuracy
±3° @ -50° to 0°
±1° @ 0° to 100°
±3° @ 100° to 150°
Temperature Coefficient: <0.1 x the applicable accuracy specification
per °C, from 0°C to 18°C and 28°C to 50°C
Fahrenheit
Range
-58°F to 302°F
Resolution
1°F
Accuracy
±6° @ -58° to 32°
±2° @ 32° to 212°
±6° @ 212° to 302°
Temperature Coefficient: <0.1 x the applicable accuracy specification
per °F, from 32°F to 64.4°F to 122°F
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Logic Circuit Test Probes
PR21 Logic Probe
• Perfect Trouble Shooting Tool
• 20MHz Pulse Detector
• Switch Selectable
- Pulse Detection or Memory
- TTL/CMOS
• Audible Logic State Tones
• Input Impedance 1MΩ
• Detects 30ns Pulses
• Operates to 20MHz
• Color Coded LEDs
• Circuit Powered
• 90-Day Limited Warranty
DESCRIPTION:
The PR21 is a versatile instrument for troubleshooting and analyzing logic
circuits. Features include visual indication of pulse level and pulse
presence, pulse memory, plus an audible, two-tone, logic state indicator.
The probe responds to pulses as narrow as 30ns and pulse trains up to
20MHz, and is compatible with TTL, DTL, RTL, HTL, CMOS and MOS. It is
also compact and light weight. Three color-coded LEDs indicate pulse
presence and high/low logic states. Visual indication is complemented by
audible tones of two distinctly different frequencies to distinguish the
logic states easily. The PR21 Logic Probe is a valuable servicing aid,
especially when used in conjunction with the PR31 Logic Pulsar.
SPECIFICATIONS:
Input Signal Frequency: 20MHz Max
Minimum Detectable Pulse Width: 30ns
Input Impedance: 1MΩ
Operating Supply Range (Vcc): 4V DC Min., 18V DC Max.
TTL Logic “1” (Hi LED) >2.3 ±0.2V DC
Logic “0” (Lo LED)
<0.8 ±0.2V DC
CMOS Logic “1” (Hi LED) >70% Vcc ±10%
Logic “0” (Lo LED)
<30% Vcc ±10%
Maximum Allowable Supply Voltage (Vcc): ± 20V DC
Power Supply Protection: ±20V DC Max. (15 sec.)
Signal Input Protection: ±220V AC/DC Max. (15 sec.)
Pulse Indicator Flash Time: 500ms
Operating Environment: 0°C to 50°C, <80% relative humidity
Storage Environment: -20°C to 65°C, <75% relative humidity
Dimensions, Weight: 8.2" long x 0.7" dia. (21cm x 1.8cm)
net weight 1.6 oz. (45g)
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
21
Logic Circuit Test Probes
PR31 Logic Probe
• Trouble Shooting/Design Tool
• Pulse Generator
• Use with Companion Logic Probe
PR21 or Scope
• Compatible with Most Logic Families
• Signal Injector (Square Wave)
• Switchable 0.5/400Hz Pulse Rate
• Sources/Sinks 100mA Pulses
• External Sync Input
• Circuit Powered
• 90-Day Limited Warranty
DESCRIPTION:
The PR31 Pulse Generator is used to inject a signal into a logic circuit
without having to remove the IC or open the circuit. Using the companion
PR21 Logic Probe you can detect component failures or wiring errors. The
average power of the injected signal is limited by supply voltage (Vcc) of
the circuit under test, and with its short duration pulses, will not damage
circuit components.
The PR31 Logic Pulsar produces a 10µs signal at a 100 mA load and can
be switched to either 0.5Hz or 400Hz. It is also capable of generating a
square wave equal to approximately 90% of the supply voltage (Vcc) at
the square wave output terminal so that an oscilloscope can be used to
observe and trace signals. The PR31 Logic Pulsar also has an external
sync input, which enables the user to synchronize the pulse output with
an external signal, such as a computer clock circuit.
SPECIFICATIONS:
Input Signal Frequency: 20MHz Max
Minimum Detectable Pulse Width: 30ns
Input Impedance: 1MΩ
Operating Supply Range (Vcc): 4V DC Min., 18V DC Max.
TTL Logic “1” (Hi LED) >2.3 ±0.2V DC
Logic “0” (Lo LED)
<0.8 ±0.2V DC
CMOS Logic “1” (Hi LED) >70% Vcc ±10%
Logic “0” (Lo LED)
<30% Vcc ±10%
Maximum Allowable Supply Voltage (Vcc): ± 20V DC
Power Supply Protection: ±20V DC Max. (15 sec.)
Signal Input Protection: ±220V AC/DC Max. (15 sec.)
Pulse Indicator Flash Time: 500ms
Operating Environment: 0°C to 50°C, <80% relative humidity
Storage Environment: -20°C to 65°C, <75% relative humidity
Dimensions, Weight: 8.2" long x 0.7" dia. (21cm x 1.8cm)
net weight 1.6 oz. (45g)
22
Output Pulse Rate: 0.5/400Hz
Output Pulse Width: 10-15µs
Output Pulse Amplitude: Approx. 90% Vcc
Output Current: 100mA Sink/Source
Square Wave Output Current: 5mA Sink/Source
Sync Input Impedance: 1MΩ
Power Supply Range (Vcc): 5-15V DC
Overload Protection:
Power Supply
20V DC Max. (30 sec.)
Sync Input
120V DC Max. (30 sec.)
Test Point
35V DC Max. (30 sec.)
Operating Environment: 0°C to 50°C, <80% relative humidity
Storage Environment: -20°C to 65°C, <75% relative humidity
Dimensions, Weight: 8.2" long x 0.7" dia. (21cm x 1.8cm)
net weight 1.4oz. (40g)
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Oscilloscope Probes
PR60, PR100, PR200B
• High Quality At Economical Prices
• Compatible with Popular Scopes
• Switchable X1, X10 and
Ground Reference
• Stable Calibration
• Ground Clip Rotates 360°
• Pin-Point Probe Tip
• 90-Day Limited Warranty
P®200B
PR100
PR60
PR100
PR200B
• 60 MHz Bandwidth
• 100 MHz Bandwidth
• 200 MHz Bandwidth
SPECIFICATIONS:
SPECIFICATIONS:
SPECIFICATIONS:
Switch Function
Switch Function
Switch Function
X1:
Attenuation: 1:1
Bandwidth: DC to 20MHz
Input Capacitance: 72pf
Input Resistance: 237Ω
X10:
Attenuation: 10:1
Bandwidth: DC to 60MHz
Internal Resistance: 9MΩ
Compensation Range: 15 to 40pF
Input Capacitance: 14pF
Input Resistance:
10MΩ, with Oscilloscope of
1MΩ Input Resistance
Working Voltage: 600V AC p-p or 300V DC
+ AC p-p
Operating Temperature: -15°C to +70°C
Coaxial Cable Length: 53.6" (1363mm)
X1:
Attenuation: 1:1
Bandwidth: DC to 10MHz
Rise Time: 35ns
Input Capacitance: 75pf + Oscilloscope
Input Capacitance
X10:
Attenuation: 10:1
Bandwidth: DC to 100MHz
Rise Time: 3.5ns
Compensation Range: 15 to 50pF
Input Resistance:
10MΩ, with Oscilloscope of
1.0MΩ Input Resistance
Input Capacitance: 11pF
Reference Position: Tip Grounded via 9MΩ,
Oscilloscope Input Grounded
Working Voltage: 600V (DC + peak AC)
Operating Temperature: 0°C to +70°C
Coaxial Cable Length: 57" (1478mm)
X1:
Attenuation: 1:1
Bandwidth: DC to 5MHz
Rise Time: 75ns
Input Capacitance: 60pf + Oscilloscope
Input Capacitance
X10:
Attenuation: 10:1 (±3%)
Bandwidth: DC to 200MHz
Rise Time: 1.8ns
Compensation Range: 10 to 60pF
Input Resistance:
10MΩ, with Oscilloscope of
1.0MΩ Input Resistance
Input Capacitance: 14pF
Reference Position: Tip Grounded via 9MΩ,
Oscilloscope Input Grounded
Working Voltage: 600V (DC + peak AC)
Operating Temperature: 0°C to +70°C
Coaxial Cable Length: 47.2" (1200mm)
Accessories Supplied
Accessories Supplied
Ground Lead and Clip Retractable Hook
IC Tip
Insulating Tip
BNC Adapter
Trimmer Tool
Ground Lead and Clip Retractable Hook
IC Tip
Insulating Tip
BNC Adapter
Trimmer Tool
Replacement Tip
Accessories Supplied
Ground Lead and Clip
Retractable Hook
Replacement Accessories
PR200BGL - Ground Lead and Clip
PR60SH - Retractable Hook
Replacement Accessories
PR200BGL - Ground Lead and Clip
PR200BSH - Retractable Hook
PR200BKT Accessory Kit: Ground Lead and
Clip; IC Tip; BNC Adapter; Retractable Hook;
Insulating Tip; Trimmer Tool
Replacement Accessories
PR200BGL - Ground Lead and Clip
PR200BSH - Retractable Hook
PR200BKT Accessory Kit: Ground Lead and
Clip; IC Tip; BNC Adapter; Retractable Hook;
Insulating Tip; Trimmer Tool; Replacement Tip
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
23
Accessories
Soft Carrying Cases
• Cloth Reinforced Vinyl
• Double Machine Stitched
• Cushion Lining
• Dependable Fasteners
• Carrying Handles
MC-30
MC-20
MC-50
DESCRIPTION:
Meter Model No.
AM-20
AM-30
CX-920A
DM-21
DM-50
DM-59
DM-75
DM-80
DM-37
DM-78A
DM-500
Part No.
MC-20
MC-30
MC-50
Dimensions (Nom.)
7 in. x 5.75 in. x 1.25 in.
6.5 in. x 4 in. x 1.5 in.
MC-500
MC-80
MC-300
8 in. x 5 in. x 2 in.
MC-500
MC-80
Protective Holster and Tilt Stand
• Fitted
• Resilient Molded Plastic
• Belt Clip
DESCRIPTION:
Meter Model No.
DM-500
24
MH-500
Part No.
MH-500
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Accessories
ML-370
Replacement Test Leads
ML-10
• Flexible • Heavy Duty • Insulated
DESCRIPTION:
Meter Model No.
AM-10
AM-30
FET-43
DM-37
AM-22
DM-21
DM-50
DM-59
DM-78A
DM-80
DM-500
CX-920A
Part No.
ML-10
ML-43
Length (Nom.)
26.5 in.
43 in.
ML-30
ML-375
ML-370
48 in.
(Includes alligator clips)
ML-375
42 in.
ML-920A
13 in.
ML-43
ML-920A
MULTIMETER TEST LEADS - CROSS REFERENCE
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Meter Mfg./ ECG
Model No.
Repl.
Amprobe
Beckman/
Wavetek
HD-130.......ML-370
HD-140.......ML-370
RMS225 .....ML-370
TECH300 ......ML-43
TECH310 ......ML-43
TECH320 ......ML-43
TECH330 ......ML-43
TECH350 ....ML-370
TECH360 ....ML-370
75...............ML-370
77...............ML-370
79...............ML-370
83...............ML-370
85...............ML-370
87...............ML-370
8020B .......ML-370
8021B .......ML-370
8022B ........ML-370
8024B ........ML-370
8026B ........ML-370
8050A.........ML-370
8060A.........ML-370
8062A.........ML-370
Goldstar
DM-1835....ML-370
DM-6335....ML-370
DM-7143....ML-370
DM-7333....ML-370
DM-8243....ML-370
DM-8433....ML-370
Hitachi
Philips ECG
3510...........ML-370
3525...........ML-370
3550...........ML-370
AM-10 ..........ML-10
AM-20 ..........ML-43
AM-22 ........ML-375
AM-30 ..........ML-43
CM-30 ..........ML-30
CM-33 ................—
CX-920 ...............—
CX-920A...ML-920A
DM-21 ........ML-375
DM-25 ................—
DM-26 ................—
DM-27 ................—
DM-50 ........ML-375
DM-51 ................—
DM-53 ................—
DM-55L ..............—
DM-59 ........ML-375
DM-71 ........ML-370
DM-74 ........ML-370
DM-75 ................—
DM-76 ........ML-370
DM-78 ........ML-375
DM-78A......ML-375
DM-80 ........ML-375
DM-300......ML-370
DM-305......ML-375
DM-305A....ML-375
DM-310......ML-370
DM-410......ML-370
DM-500......ML-375
FET-43..........ML-43
DVM-634 ......ML-43
DVM-636 ......ML-43
DVM-638 ......ML-43
DVM-642 ....ML-375
DVM-6005 ..........—
LCR-680 .............—
DM-6910....ML-370
DM-7010....ML-370
DM-8010....ML-370
DSA-2002...ML-370
DSA-2002P.ML-370
DSA-2003...ML-370
DSA-2007...ML-370
DSA-2007A.ML-370
DSA-2009...ML-370
SP-170B.......ML-43
SP-250B.......ML-43
SPR-300+ ..ML-370
SPR-931.....ML-370
TD-2608.....ML-370
TD-2608A...ML-370
AM-4A ..........ML-43
AM-4B ........ML-370
AM-1200 ....ML-375
AM-1280 ....ML-375
B&K
213...............ML-43
340A.............ML-30
350.............ML-370
377.....................—
388HD ........ML-370
388A...........ML-375
389.............ML-375
390.............ML-375
391.............ML-375
815.............ML-375
2703...................—
2703A.........ML-370
2704...................—
2704A.........ML-370
2706...........ML-370
2707...........ML-370
2806...........ML-370
2807...........ML-370
2816...........ML-370
2817...........ML-370
2845...........ML-370
2860...........ML-375
2905...........ML-370
2906...........ML-370
2907...........ML-370
2911...........ML-370
2912...........ML-370
2940...........ML-370
2945...........ML-370
151.............ML-370
152.............ML-370
153.............ML-370
300.............ML-370
310.............ML-370
320.............ML-370
330.............ML-370
350.............ML-370
360.............ML-370
3000.............ML-43
3010.............ML-43
3010UL.........ML-43
3020.............ML-43
3020B ..........ML-43
3030.............ML-43
3050...........ML-370
3060...........ML-370
4410...........ML-370
DM10 .................—
DM15B ...............—
DM20L................—
DM23 .................—
DM25L................—
DM25XL..............—
DM27XL..............—
DM800 .......ML-370
DM850 .......ML-370
DM-10 ..........ML-43
DM-40 ........ML-370
DM-45 ........ML-370
DM-50 ........ML-370
HD-100.......ML-370
HD-110.......ML-370
Extech
380165...............—
380166...............—
380168.......ML-375
308196.......ML-375
380198.......ML-375
380451.......ML-370
380650.........ML-30
380776.......ML-370
380911 ........ML375
380972.......ML-370
383487.......ML-370
Fluke
10...............ML-370
11...............ML-375
12...............ML-375
21...............ML-375
23...............ML-370
25...............ML-370
27...............ML-370
29...............ML-370
37...............ML-370
45...............ML-370
70...............ML-370
73...............ML-370
Heathkit
2208.............ML-30
2311...................—
2372...................—
2374...................—
2380...........ML-375
SM-77 ........ML-370
H. P.
E2373A.......ML-370
E2377A.......ML-370
E2378A.......ML-370
Mercer
9120.............ML-43
9301...........ML-370
9370...........ML-370
9401...........ML-370
9702.............ML-30
Protek
301U...................—
505.............ML-375
A800.............ML-10
A802...........ML-375
A803.............ML-43
A-400 ...........ML-43
A-420S .........ML-43
A-423 ...........ML-43
A-423..........TC-50P
A-445 ...........ML-43
A-450 ...........ML-43
D-901 .................—
D-902.........ML-370
D-906.........ML-370
D-910F .......ML-370
D-910F........TC-50P
D-927.........ML-370
D-937.........ML-370
D-945 ........ML-370
D-981.........ML-370
D-981..........TC-50P
D-982.........ML-370
Scope
DCM-602............—
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Simpson
470.............ML-370
474.............ML-370
Soar
3025...........ML-370
3030...........ML-370
3050...........ML-370
3200...........ML-370
3210...........ML-370
3220...........ML-370
3230...........ML-370
3430...........ML-370
3450...........ML-370
3510...........ML-370
3520...........ML-370
4010...........ML-370
4020...........ML-370
4030...........ML-370
4040...........ML-370
4050...........ML-370
5025...........ML-370
5026...........ML-370
5030...........ML-370
A. W. Sperry
DM-3010....ML-370
DM-4000A ..........—
DM-6510....ML-370
Tektronix
DM250 .......ML-375
DM251 .......ML-375
DM253 .......ML-375
DM254 .......ML-375
DM255 .......ML-370
DM256 .......ML-370
DM257 .......ML-370
Triplett
50...............ML-370
3350...........ML-370
3360...........ML-370
3500...........ML-370
3550...........ML-370
3560...........ML-370
3565...........ML-370
4700...........ML-370
4750...........ML-370
4800...........ML-370
25
Accessories
Replacement
Thermocouples (K-Type)
DESCRIPTION:
Meter Model No.
DM-80
DM-500
DESCRIPTION:
TC-50P (With Connector)
TC-50P (With Connector)
Temperature Probe
DESCRIPTION:
Meter Model No.
AM-30
26
Replacement Oscilloscope
Probe Accessories
Probe Model No.
PR200B
Part No.
PR200BSH (Retractable Hook)
K-Type Temperature Probe
Adapter
DESCRIPTION:
TC-30
Meter Model No.
DM-500
800-631-1250 • www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
Part No.
MA-500
Distributed by:
Test Equipment
® Copyright 2003 NTE Electronics, Inc.
NTE Electronics, Inc.
44 Farrand Street,
Bloomfield, NJ 07003
Phone: 973-748-5089
Fax: 973-748-6224
www.nteinc.com
Downloaded from Elcodis.com electronic components distributor
ECG® is a registered trademark
of NTE Electronics, Inc
EL37-01
Download PDF
Similar pages