PNet Installation and User Guide_81905906860_A

INSTALLATION & USER GUIDE
ROUTER CONTROL SOFTWARE APPLICATION
®
FOR W INDOWS BASED PCS
Publication: 81-9059-0686-0, Rev. A
March, 2011
www.pesa.com
Phone: 256.726.9200
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Thank You !! for purchasing your new PESA router control software application. We appreciate
your confidence in our products. PESA produces quality, state-of-the-art equipment designed to
deliver our users the highest degree of performance, dependability and versatility available anywhere.
We want you to know that if you ever have a concern or problem with a PESA product, we have a
team of engineers, technicians and customer service professionals available 24/7/365 to help resolve
the issue.
Our commitment is to continue earning the trust and confidence of our customers throughout the
industry by incorporating cutting-edge technology into the highest quality, most cost effective products
on the market. And we would like to invite you to tell us how we’re doing. If you have any comments
or suggestions concerning your PESA equipment, please contact our Customer Service Department.
Again, thank you for choosing PESA and we look forward to a long-term partnership with you and
your facility.
SALES, SERVICE AND ORDERING
ASSISTANCE
PESA Corporation
103 Quality Circle, Suite 210
Huntsville AL 35806 USA
www.pesa.com
SERVICE DEPARTMENT
Tel: 256.726.9222 (24/7)
Toll Free: 800.323.7372
Fax: 256.726.9268
Email: service@pesa.com
MAIN OFFICE
Tel: 256.726.9200
Fax: 256.726.9271
© 2011 PESA, All Rights Reserved.
Microsoft, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or
other countries.
No part of this publication (including text, illustrations, tables, and charts) may be reproduced, stored in any retrieval system, or transmitted
in any form or by any means, including but not limited to electronic, mechanical, photocopying, recording or otherwise, without the prior
written permission of PESA.
All information, illustrations, and specifications contained in this publication are based on the latest product information available at the time
of publication approval. The right is reserved to make changes at any time without notice.
Printed in the United States of America.
Proprietary Information of PESA
I
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
TABLE OF CONTENTS
CHAPTER 1
INTRODUCTION ........................................................................................................... 1-1
DESCRIPTION .................................................................................................................... 1-1
1.1
CHAPTER 2
SOFTWARE INSTALLATION AND LICENSING ...................................................... 2-1
2.1
LICENSING PNET SOFT PANELS .......................................................................................... 2-1
2.2
30 DAY EVALUATION PERIOD ............................................................................................ 2-1
2.3
SYSTEM REQUIREMENTS .................................................................................................... 2-1
2.4
DOWNLOAD AND INSTALL ROUTER PANEL APPLICATION .................................................... 2-1
2.5
LICENSE INSTALLATION AND ACTIVATION ......................................................................... 2-4
2.6
REMOVING ROUTER PANEL INSTALLATION ........................................................................ 2-8
CHAPTER 3
PNET SOFT PANEL CONFIGURATION..................................................................... 3-1
3.1
CONFIGURATION REQUIREMENTS....................................................................................... 3-1
3.2
PANEL CONFIGURATION THROUGH CATTRAX ..................................................................... 3-1
3.3
PANELS CONFIGURATION SCREEN ...................................................................................... 3-2
CHAPTER 4
4.1
OPERATION .................................................................................................................. 4-1
ACTIVATE PNET SOFT PANEL ............................................................................................ 4-1
4.2
PNET SWITCHING METHODS .............................................................................................. 4-3
All Levels Switch ....................................................................................................................................... 4-3
Breakaway Switch...................................................................................................................................... 4-3
4.3
PNET SWITCHING MODES .................................................................................................. 4-3
Hot-Take Switching Mode.......................................................................................................................... 4-3
Preset Switching Mode............................................................................................................................... 4-3
4.4
CONTROL PANEL CONFIGURATION ..................................................................................... 4-3
4.5
PNET PANEL - KEY FUNCTIONS ......................................................................................... 4-4
4.6
STATUS AND T ALLY FUNCTIONS ........................................................................................ 4-5
Destination Status....................................................................................................................................... 4-5
Source Status 4-6
Switching Levels Status.............................................................................................................................. 4-6
4.7
PNET SOFT PANEL OPERATION .......................................................................................... 4-7
Performing a Hot-Take, All-Levels Switch ................................................................................................. 4-7
Hot-Take, Breakaway Switching................................................................................................................. 4-8
Performing a PRESET Switch .................................................................................................................... 4-9
4.8
APPLYING DESTINATION PROTECT OR LOCK..................................................................... 4-10
LIST OF FIGURES
FIGURE 1-1
FIGURE 3-1
FIGURE 3-2
FIGURE 4-1
FIGURE 4-2
PNET SOFT PANELS – DISPLAY E XAMPLES ................................................................................................... 1-2
PANELS CONFIGURATION SCREEN ................................................................................................................ 3-2
ADDING A PANEL CONFIGURATION .............................................................................................................. 3-3
PNET CONTROL PANEL LAYOUT (EXCEPT P3232 PANEL).............................................................................. 4-4
PNET 3232 CONTROL PANEL LAYOUT .......................................................................................................... 4-4
Proprietary Information of PESA
II
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Chapter 1 Introduction
1.1
DESCRIPTION
PESA’s PNet Soft Panel PC-based router system control panels emulate functionality of the family of
PNet hardware panels, and allow control of PESA routers such as the Cougar3 from virtually any
computer in your facility. Soft panels are installed and activated through Router Panel, a software
application that installs on PCs running the Microsoft Windows® XP, Vista or Windows 7 Operating
System. Router Panel software must be loaded and resident on each host computer on which you wish
to activate a soft panel. Soft panels operate exclusively with routers equipped with PESA’s Small Scale
System Controller (SSC) and offer a convenient, cost effective alternative to hardware panels. A SSC
controller can support up to 80 PNet panels in any combination of soft panels and hardware panels.
The Router Panel application supports software emulation of any of the hardware PNet panel variants,
and allows you to select the panel that best fits the needs of an individual control station requirement
from the following available panel types:
•
PNet Soft 1604 – Allows you to control up to 16 sources on up to 4 output destinations.
•
PNet Soft 1616 – Allows you to control up to 16 sources on up to 16 output destinations.
•
PNet Soft 3232 - Allows you to control up to 32 sources on up to 32 output destinations with a
single set of numeric keys that are shared for source and destination entry and status monitoring.
•
PNet Soft 23232 - Allows you to control up to 32 sources on up to 32 output destinations with a
separate set of numeric keys for source and destination entry, allowing simultaneous status
monitoring of both the active source and destination.
PNet soft panel instances are controlled under license management configured through PESA’s Cattrax
system control software application. The Router Panel application may be loaded onto as many
computers as desired and you may use any soft panel type or multiple types. Through Cattrax menu
screens you obtain the soft panel device license from PESA, and then apply a device key to the selected
small scale system controller to which you wish to interface soft panel control. The SSC stores the
device license key which determines the maximum number of licensed soft panels allowed to
concurrently operate with the system controller. Soft panel licenses are offered in a variety of quantity
configurations.
Whenever soft control panel emulation is initiated on a host computer, it contacts the SSC and, if a
license is available (meaning there are less soft panel instances currently on-line than the maximum
number allowed by the license), the SSC allows the soft panel to operate and provides configuration
information for that panel. Remember that every individual active, on-line panel instance, even if
opened on the same host PC, requires a separate license issued by the SSC controller. Before a soft
panel instance can be activated, it must be configured through Cattrax just as any hardware PNet panel.
All PNet panels, both soft panels and hardware panels, communicate with the system controller over an
Ethernet interface, either through a closed-loop Ethernet configuration or with full integration into the
facility network. With soft panels, each PC running the panel application communicates with the
system controller using the IP address and other network parameters of the host computer.
Proprietary Information of PESA
1-1
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
PNet soft panel instances may be activated in any of several panel configurations that vary the number
of sources and destinations each can control, but all panels provide the following common capabilities:
•
All-level, audio-follow-video (AFV) switching
•
Breakaway switching on up to 8 switching levels
•
Operate in hot-take or preset panel modes
•
Destination protect and lock features
•
Source and destination key channel assignments configurable through Cattrax
•
Single button “Take” for preset switches
•
Each source, destination and switching level key for which there is a valid definition through
the data key list is displayed with the ID name assigned to the signal or level during
configuration inserted into the pushbuttong graphic
Figure 1-1 illustrates screen display of the various available soft panel types.
Figure 1-1 PNet Soft Panels – Display Examples
Proprietary Information of PESA
1-2
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Chapter 2 Software Installation and Licensing
2.1
LICENSING PNET SOFT PANELS
Prior to creating or configuring PNet soft panels, you must install the Router Panel software application
on every computer you intend to use as a host PC for a soft panel instance. You must also obtain and
install a license key to the SSC system controller in the router by using menu screens of the Cattrax
system control application. Once you have the panel license installed, you may create, configure and
operate soft panels on as many host computers as you wish, and use any type of soft panel available
through the software – up to the number of panels allowed by the license. Each active, on-line soft
panel requires a license be available through the SSC. Licenses, however, do not follow a particular
panel; but are dynamically issued only to active panels for the time the panel is on-line. If any panel
should ever be taken off-line, another soft panel may use the available license vacated by the off-line
panel.
2.2
30 DAY EVALUATION PERIOD
PESA offers a trial version of PNet soft panels that allows you to evaluate the application for a period of
30 days. All panel types are fully functional with the trial version, and you can load the application onto
as many host computers as you wish. With the trial version, however, the system controller will only
allow three simultaneous on-line panel connections. The trial version may be upgraded at any time
during or after the trial period by obtaining a license activation key from PESA.
2.3
SYSTEM REQUIREMENTS
In order to use PNet soft panels with your router you must have the following:
•
Cattrax V2.4.2 or higher installed on a host PC communicating with the SSC in the router.
•
Small Scale System Controller installed in the router frame, running operating system V1.6 or
higher.
In addition, it is highly recommended that you have:
•
Internet access
•
Valid e-mail address
However, if you do not have either of these items, there is a process for manually obtaining and entering
license management, refer to Paragraph 2.XX.
2.4 DOWNLOAD AND INSTALL ROUTER PANEL APPLICATION
PNet Soft Panels are activated through PESA’s Router Panel software application installed on a
standard PC running the Microsoft Windows® XP, Vista or Windows 7 Operating System.
The application contains an auto-run file that guides you through the installation process. Examples of
the pop-up screens you will see are shown below with the appropriate step. Notice the “X” used in place
of actual values on each example screen presented here. During installation the release number of
Router Panel software you are installing is displayed.
Proprietary Information of PESA
2-1
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Install Router Panel application as follows:
•
Download Router Panel software installation file from the PESA website to a convenient
directory folder on the host PC. You may download the trial version or permanent version from
the website.
•
On completion of download, a zipped file is copied to the folder which contains a PDF file with
soft panel license information and an auto-run executable file for Router Panel installation.
•
If the auto-run function does not automatically launch, navigate to the directory of the disk drive
containing the zipped file, unzip the file to a convenient directory and double click the Router
Panel-Setup.exe file. The banner shown below should be displayed on the desktop. Click Next
to begin installation.
•
By default auto-install creates the folder shown below for the Router Panel application. If you
wish to install the software in a directory or folder other than the default, click Browse and
navigate to the destination. Click Install to continue installation.
Proprietary Information of PESA
2-2
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
During installation, an indicator bar tracks progress of software load. Upon completion of
installation, an “Installation Complete” prompt is displayed. An example completion screen is
shown below.
Proprietary Information of PESA
2-3
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
2.5
Click Finish to exit the installation process. During installation a shortcut icon to access the soft
panel configuration box is automatically placed on the desktop. If the box next to “Run Router
Panel X.X” is checked, the application will start immediately.
LICENSE INSTALLATION AND ACTIVATION
Soft panel licenses installed and activated through Cattrax license management process never expire,
and you can create and configure as many soft panels on as many host computers as you wish.
However, the number of simultaneous active, on-line panel connections permitted is determined by the
license quantity provided by the management package installed to the system controller.
The following steps guide you through the process of obtaining and installing panel device license
management:
1. Decide the quantity of soft panels you need and purchase the desired PNET-SOFT license pack.
2. PESA will generate and e-mail you a Soft Panel License Management Activation Key. The
activation key is a quite lengthy computer-generated character string. You may use the
Windows® copy and paste function to copy the characters from the e-mail you receive to the
key entry form in Cattrax.
3. Start the Cattrax router control program on a host computer actively communicating with the
SSC controller in the router frame.
4. From the Cattrax home screen, click the Tools tab on the menu bar and then select the License
Control icon in the Tools menu, as shown below.
5. The License Control window opens and prompts you to select the SSC controller device on
which you wish to install soft panel license management from the pull-down menu, as shown in
the following example window.
Proprietary Information of PESA
2-4
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
6. Click the New button and the License Activation – Device window opens as shown by the
example window below.
Proprietary Information of PESA
2-5
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
7. Copy and paste, or enter, the Activation Key character string you received from PESA in the
Activation Key box.
8. Enter a valid e-mail address in the Your Email box
9. The device serial number and type are read from the selected device and entered for you.
10. Click the Activate License button to send the activation request immediately to PESA.
11. If you have an active internet connection, PESA’s license management server will process the
request and return a Device Key character string. The character string is automatically entered
in the Device Key box upon receipt and a dialog box alerts you that the key is received, as
shown below.
12. Click the OK button to activate the device license.
13. If the router is equipped with a secondary system controller, a prompt box will alert you that the
primary and secondary controllers have different licensing, and ask if you want to update the
second controller to the same device key as the primary, as shown below. PESA allows you to
install the device key on two controllers so that in a redundant system, the controllers are
licensed the same. In most installations you will click Yes to update the secondary controller.
If for some reason, you choose not to update the secondary controller, click No to close the
prompt box and activate the new device key only on the primary controller.
Proprietary Information of PESA
2-6
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
2.6
MANUAL LICENSE ACTIVATION
In the event that internet access to PESA’s license server is not immediately available on the panel host
PC, you may complete the licensing process through Email communication with PESA.
The following steps guide you through the process of manually obtaining and installing panel device
license management:
1. Follow Steps 1 – 9 in Paragraph 2.5, above.
2. Click the Save License Information button to create and save a data file used for manual license
activation.
3. A Save As dialog box, as shown below, displays with the folder, file name and file type filled
in. Click the Save button to write the file to the Cattrax folder.
Proprietary Information of PESA
2-7
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
4. Open your Email program and attach the file you just created in the Cattrax folder to the Email
and send it to license@pesa.com. This file contains all the system information and activation
key needed to issue a device key.
5. A device key will be created and sent to you by Email.
6. Follow Steps 3 – 6 of Paragraph 2.5, above to open the License Activation – Device window.
7. Copy and paste, or enter, the Device Key character string sent to you by Email in the Device
Key data entry box at the bottom of the dialog window.
8. Follow Steps 12 and 13 of Paragraph 2.5, above to complete activation of device licensing.
If you ever wish to review the status and key numbers of a license installation, use the License Control
icon in the Tools menu to open the License Control window as shown below.
2.7 REMOVING ROUTER PANEL INSTALLATION
Should it ever be necessary to remove the Router Panel software application from a panel host PC, an
uninstall command is available through the Start menu of the Windows® operating system. A prompt
window as shown below is displayed on the desktop. Click Uninstall to complete the command.
Proprietary Information of PESA
2-8
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
If you have soft panels created and configured, the following prompt appears and gives you the
option of uninstalling the configuration application, but retaining the configured panels so that
you do not have to re-configure panels when updating or re-installing the panel software. If you
wish to remove all instances of created soft panels from the computer, click the Yes button.
Proprietary Information of PESA
2-9
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Chapter 3 PNet Soft Panel Configuration
3.1
CONFIGURATION REQUIREMENTS
In order for a PNet soft panel to be functional, the host computer running the Router Panel application
must have established Ethernet communication with the SSC controller in the video router frame, and
panel operating parameters must be configured through Cattrax into the system controller configuration
file. There are several operating parameters we must define for each soft panel as part of creating the
configuration file, including associating a data key list with each soft panel instance. Through the
creation of data key lists, we assign specific switching levels, source groups and destination groups to
specific pushbuttons on the PNet panel. Also during control panel configuration a Status Level and
Default Destination must be specified for each panel. With panel configuration data entered, the
configuration file with panel operating parameters must be downloaded and become the active
configuration file used by the system controller in order for the panel to be functional.
Adding a PNet soft panel to a router system requires the following procedures be completed:
3.2
•
Install PNet Router Panel software application on a host PC, see Chapter 2 of this guide.
•
Ensure there is functional Ethernet communication between the host PC and the SSC device
with which you wish to use the soft panel.
•
Determine the panel type, or types, you wish to operate on the host PC from the choices
available through the software application.
•
Through operator screens of Cattrax, create a system controller configuration file with the PNet
soft panel operating parameters added, refer to Paragraph 3.2. An individual panel
configuration entry is required for each soft panel instance. The newly created controller
configuration file must be downloaded and running as the active controller configuration
BEFORE you can set-up panel instances on the host PC.
•
Launch Router Panel application on host PC, set-up and activate soft panel instance, refer to
Chapter 4 of this guide.
PANEL CONFIGURATION THROUGH CATTRAX
Before you can activate a soft panel on a host computer, you must first add the panel to the controller
configuration file through menu screens of Cattrax. Adding and configuring a PNet soft panel is very
similar to configuring a hardware panel, and it is assumed that you are familiar with the steps and
procedures required to add a hard panel to the SSC controller configuration file. If you are not already
familiar with these procedures, a brief discussion of PESA’s control system and the requirements for
creating data key lists and configuring hardware PNet panels is contained in Chapter 4 of the User
Guide for your router. Please review this information before proceeding with soft panel configuration.
Be sure that the configuration file to which you wish to add the soft panels is loaded into Cattrax, either
by uploading the currently active file from the system controller, or retrieving a saved file from a
storage device.
Proprietary Information of PESA
3-1
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
3.3
PANELS CONFIGURATION SCREEN
The Panels Configuration Screen, Figure 3-1, allows you to add PNet control panels to the system,
program the functionality of each panel, and review the configuration of existing panels. Clicking on the
Panels parent entry in the SSC Configuration menu brings up the panels configuration screen.
Figure 3-1 Panels Configuration Screen
•
Adding a Control Panel –To add a PNet soft panel, click the Add button at the bottom of the
Panel Name list box. A place-holder name is added to the list name box; however, it may be
changed through the configuration set-up entries. Choosing the Add function also creates a data
entry row in the panel configuration box for you to enter set-up data for the new panel.
•
Defining a PNet Soft Panel - In the middle of this screen you will see a spreadsheet format
table, Figure 3-2, with an entry for each PNet panel in the system. Anytime a panel entry in the
listing window is highlighted, a graphic image of that panel type is displayed at the top of the
configuration screen. If you are adding a new panel to the listing, the graphic image of the panel
is displayed once the panel type parameter is selected. Displaying a graphic image allows you to
verify the panel type as well as provide a visual cue of the features and functions of the specific
panel.
Proprietary Information of PESA
3-2
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Figure 3-2 Adding a Panel Configuration
•
Enter Panel Configuration Data
-
Panel ID – With PNet soft panels, the Panel ID number creates a unique configuration
entry and identifier for the panel; it is not a hardware ID number as with PNet hardware
panels, and may be changed to any unused value you wish. Many users create a unique
block of numbers that identify the panels in the group as being soft panels. While the soft
panel ID entry does not identify a specific piece of hardware, each individual soft panel you
configure must have a unique Panel ID entry.
-
Name – This entry allows you to assign a name to each panel. If you are adding a new
panel, the place-holder name entered by Cattrax will initially appear in this column. You
may change the name to a more descriptive panel name if you wish. A panel name may
consist of a mix of alphanumeric characters. This is the text string displayed in other
configuration and status screens to identify the panel.
-
Type – This column allows you to select the soft panel type you will activate on the host
PC using a pull-down menu of all available soft panel types. Click in the Type cell and
open the pull-down menu. Select the panel type you are configuring and click the entry. The
type number appears in the cell and a graphic image of the panel is displayed on the
configuration screen.
-
IP Address – Each host computer running Router Panel software must be assigned a unique
and valid IP address that is compatible with the facility network or closed Ethernet loop. In
most cases, IP addresses are issued by the facility network administrator. Enter the IP
address of the host PC running the panel you are configuring in this column. Note that if
for some reason you are activating instances of different soft panel types on the same
computer, you will enter the same IP address for each panel configured on that PC.
Proprietary Information of PESA
3-3
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
-
Destination Protect and Lock Functions
These functions are configured and operate identically to hardware PNet panels.
-
Requestor Code and Lock Priority Values
These functions are configured and operate identically to hardware PNet panels.
•
Description –The Description column is a free text field where you can enter a description
of the panel and its function or any other data you wish to enter concerning this panel.
Enter Panel Parameters
-
Enter specific operational parameters for the soft panel in the small box located in the lower
portion of the window, as shown in the illustration below. Each cell in this table uses a pulldown menu to display the options available. In order to enter or change any selection in the
configuration, click in the cell containing the parameter you want to change and click on the
pull-down arrow. From the pull-down menu, click on the selection you want to enter for the
panel configuration. This table contains the following entries:
-
Status Level – Status Level is the default switching level displayed or controlled by the
panel. To assign or edit the Status Level click in the cell and change the level selection
from the pull-down menu.
-
Status Method – The pull-down menu in this cell should always be set to Level in the
Cougar3 system application.
-
Data Key List – This entry determines the function of the configurable panel keys by
assigning a Data Key List to the panel. The desired data key list is chosen from the pulldown menu associated with the cell. Only data key lists which are valid for the panel
type are included in the pull-down menu. There is no difference between data key lists
for hardware panels and soft panels, and any valid data key list for a panel type may be
assigned to either the soft panel or hardware panel.
-
Default Destination – This entry assigns the default destination to the panel. In
operation, the default destination determines which destination is displayed and
controlled when the soft panel is first activated.
When you have completed adding and configuring soft panels to the controller configuration file, be
sure that you download the modified configuration to the controller, and, if desired, save the file to an
external storage device. You will not be able to activate soft panels on the host PC until the modified
configuration file is running on the system controller.
Proprietary Information of PESA
3-4
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
Chapter 4 Operation
4.1
ACTIVATE PNET SOFT PANEL
Launch the Router Panel application on the host PC. During installation of the software, a Router Panel
icon is placed on the PC desktop. You may start the application by clicking on the desktop icon, or
through Windows Start menus, as shown below. When the application starts, the Panel Configure
window, as shown in the example, is opened. The following steps guide you through the process of
activating a PNet soft panel on the host computer. Remember, you must have already added the soft
panel(s) you intend to activate to the controller configuration and downloaded the modified file to the
system controller.
•
Enter a Panel Name for the soft panel you are activating. This label is local to the host PC and
is displayed in the panel icon on the PC desktop. Entering a panel name is required to activate a
panel.
•
The IP address of the host PC is displayed in the Local IP box. In most cases, there will only be
one entry available in this box; if there is more than one IP associated with the host computer,
you may use the pull down list to select the address used for Ethernet communication with the
system controller. The IP address displayed in this box MUST match the IP address you
entered when configuring the soft panels in Cattrax.
Proprietary Information of PESA
4-1
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
Click the Find Controllers button to initiate a search for all compatible SSC controllers in the
network. Upon completion of search, controllers discovered are listed in the pull down list by
IP address. In most cases, there will only be one entry available in this box.
•
Select the system controller to which you want to add the soft panel from the pull down list.
•
Router Panel emulates four types of PNet panel, any, or all, of which may be active on the host
PC. You may have only configured a single panel type to run on the host PC, or you may have
created a configuration entry for all available panel types and select a different active panel as
your requirements change.
•
Open the pull down list in the Panel box. The listing identifies by name and panel type all PNet
soft panels configured through Cattrax for the host PC. The name displayed in this listing is the
panel name assigned through Cattrax and may be different than the Panel Name entered above
for the desktop icon. Note that the only soft panels that appear in the pull-down list are the ones
you have configured for the IP address of the host PC on which you are working.
•
Select the panel type you wish to activate from the pull down list and click the OK button.
•
The Panel Configure box closes and the panel emulation graphic opens with panel lights
indicating current status of the default destination for the status switching level that you entered
for the panel during configuration.
•
The soft panel is now fully functional with every feature of the equivalent hardware PNet panel.
Proprietary Information of PESA
4-2
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
4.2
PNET SWITCHING METHODS
ALL LEVELS SWITCH
All-Levels or Audio-Follow-Video (AFV) is the default switching method for the PNet soft panel upon
initialization, and is the active switching method when none of the LEVELS pushbuttons are lit. When
an AFV switch is performed, signals on all switching levels defined for the source are switched
simultaneously to all switching levels defined for the destination.
BREAKAWAY SWITCH
A Breakaway switch allows you to selectively choose specific sources for each switching level defined
for the destination.
4.3
PNET SWITCHING MODES
HOT-TAKE SWITCHING MODE
Hot-Take is the initialization default mode for the soft panel, and is the active mode of the panel when
the PRESET button is not illuminated. When Hot-Take is active, anytime you click a SOURCES
button, the input signals on the selected switching levels for that source are routed immediately to the
currently selected destination outputs. If no switching level buttons are lit (all-levels mode), source
signals from all switching levels defined for the source group are routed to the destination group
outputs.
PRESET SWITCHING MODE
Preset mode allows you to pre-define sources for an all-levels or breakaway switch on the selected
destination, but not initiate the switch until you click the TAKE button. Preset is the active switching
mode of the panel when the PRESET button is illuminated. When Preset mode is active, use the
SOURCES buttons and LEVELS buttons to define sources you wish to route to the selected destination
when the preset switch is initiated.
4.4
CONTROL PANEL CONFIGURATION
In order for a PNet soft panel to be functional, it must have Ethernet communication with the SSC3
device in the video router frame and it must be configured through Cattrax into the system controller
configuration file. There are several operating parameters we must define for each system control panel
as part of creating the configuration file. In addition to defining source and destination groups, we also
assign specific switching levels, source groups and destination groups to specific pushbuttons on the
PNet control panel through the creation of data key lists.
During control panel configuration a Status Level and Default Destination must be specified for each
panel:
•
Status Level – allows you to specify the switching level that the panel initially statuses by
default when a destination is selected, and no specific level has been selected through the levels
keys. This is also the switching level that the panel uses as the reference level when indicating
breakaway routing conditions.
Proprietary Information of PESA
4-3
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
Default Destination – defines the router destination for which the panel displays status when
initialized or following a reset.
With panel configuration data entered, the configuration file with panel operating parameters must be
downloaded and become the active configuration file used by the system controller in order for the
panel to be functional.
4.5
PNET PANEL - KEY FUNCTIONS
PNet soft panels, with the exception of the P3232 panel emulation, follow a pushbutton key layout
similar to Figure 4-1; Figure 4-2 illustrates layout of the P3232 panel. The function of each key is
presented below.
Figure 4-1 PNet Control Panel Layout (Except P3232 Panel)
Figure 4-2 PNet 3232 Control Panel Layout
•
Level Keys - On all PNet panels there are 8 Level keys that allow you to select the switching
level on which you wish to perform a breakaway switch, or display current status of the selected
level for a specific destination.
•
SOURCE Select Keys (All panels except P3232) – Select source group routed to currently
selected destination. Illuminated source button indicates selected source group.
•
DESTINATION Select Keys (All panels except P3232) – Select destination group to which
you wish to route a source. Illuminated button indicates currently selected destination group.
•
SOURCE Select Key (P3232 panel only) – Clicking the Source Select key places the
SOURCE/DEST Number keys in source select and status mode. When the Source Select key is
illuminated, clicking any number key selects the source group routed to currently selected
destination.
•
DESTINATION Select Key (P3232 panel only) - Clicking the Destination Select key places
the SOURCE/DEST Number keys in destination select and status mode. When the Destination
Select key is lit, clicking any number key selects the destination group to which you wish to
route a source.
You may click the Dest key at any time to display the currently selected destination.
Proprietary Information of PESA
4-4
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
4.6
•
SOURCE/DEST Number Keys (P3232 panel only) – Selects the source or destination,
depending on which of the Select Keys is lit.
•
Preset and Take Keys – The Preset key allows you to pre-define an all-levels or breakaway
switch and manually initiate the switch by clicking the Take key. If a source selection on one or
more switching levels is changed as a “preset” function, when the “Take” key is clicked, those
selected levels will be changed to the new source selected in the preset.
•
Protect/Lock Key – Selects and indicates lock status of currently selected destination. If the
key is not illuminated, the destination is available for switching. A momentary key click places
the active destination in “Protect” mode, whereby the protected destination can still be switched
by the panel which originally placed the destination in “Protect” mode, but is “Locked” to all
other panels and Users. When the Protect/Lock key is unlit, clicking and holding the key for
approx. 2 seconds causes the active destination to enter “Lock” mode (Lock/Protect Key
Blinking). If the Protect/Lock key is blinking, the selected destination is “Locked” for all users
and can not be switched to a different source by any panel or other user without first unlocking
the selected destination. Clicking the Lock key causes the lock state to toggle for the active
destination.
STATUS AND TALLY FUNCTIONS
Source, destination and level pushbutton keys displayed on the soft panel graphic image are labeled with
nomenclature data entered during router configuration. Source and Destination keys display the
character string entered in the Panel ID column of the configuration screen, and level keys are labeled
with the string entered in the Nickname box on the configuration screen. If a pushbutton key does not
contain a label, the key is not defined through the active data key list and is currently non-functional on
the soft panel.
Illuminated pushbuttons on the panel display graphic provide a visual indication of the status and
operating mode of the channel or panel. Visual status and tally functions are discussed in the following
paragraphs:
DESTINATION STATUS
Indicates the currently selected destination group either as a direct readout on the Destination keys, or
on the number keys when the Dest. Pushbutton is selected (P3232 Only).
Proprietary Information of PESA
4-5
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
SOURCE STATUS
Indicates the currently selected source group routed to the selected destination group, either as a direct
readout on the Source keys, or on the number keys when the Source Pushbutton is selected (P3232
Only).
•
Steady Lit Source Button - Indicates the source group definition is applied to all switching
levels.
•
Blinking Source Button – If none of the Level pushbuttons are illuminated, a blinking source
button identifies the source group currently selected on the switching level defined as status
level for the panel, and indicates the switching levels are in a breakaway condition – meaning
the source selected on one or more of the switching levels is different than the displayed source.
Selecting any of the level buttons displays the source currently selected for that switching level see Switching Levels Status, below.
•
Sources Buttons 1 and 2 Blinking Simultaneously – This condition indicates Ethernet
communication between the host PC and the system controller has been lost.
SWITCHING LEVELS STATUS
Switching LEVEL buttons select the levels for breakaway switching and level status display with the
panel operating in either Hot-Take or Preset modes. Each button is a push-on/push-off toggle function,
and is illuminated when the level is selected.
•
No Levels Selected – Indicates panel is operating in All-Levels Switch mode, and any Source
button you click will select that source on all switching levels of the source group.
For status tally, when no levels buttons are lit, the illuminated Source button indicates source
group currently selected on switching level defined as status level for the panel.
Proprietary Information of PESA
4-6
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
One or More Levels Selected – Indicates panel is operating in Breakaway Switch mode, and
selects switching levels for the breakaway switch. Any Source button you click selects that
source on selected switching levels of the source group.
Clicking any one of the level buttons selects that switching level for status display and the
corresponding illuminated Source button indicates the currently selected source for the
switching level.
If multiple Levels buttons are selected (lit), the illuminated Source button ALWAYS displays
status of the numerically lowest (with 1 being lowest and 8 being highest) selected switching
level. A blinking Source button indicates the switching levels are in a breakaway condition –
meaning the source selected on one or more of the selected switching levels is different than
that of the currently displayed level.
Remember, when no levels buttons are lit, the illuminated Source button always indicates
source group currently selected on the switching level defined as status level for the panel.
4.7
PNET SOFT PANEL OPERATION
A PNet soft panel instance may be operated through mouse clicks on the graphical pushbutton keys, or
by using a touch-screen monitor. Procedures in this paragraph discuss operation of the P3232 panel.
With the exception of the Source and Destination select keys, these procedures may be applied to any
PNet panel.
PESA routers are destination oriented, meaning that switches are made by first selecting the destination
group and then selecting the signal channels, through source groups, that you wish to route to the
destination outputs. Default operation for a PNet soft panel on initialization or reset is All Levels and
Hot Take.
PERFORMING A HOT-TAKE, ALL-LEVELS SWITCH
To perform an all-levels switch, verify that none of the levels keys are illuminated; if any are lit, the
panel is operating in breakaway mode. Click any illuminated levels keys to toggle the breakaway
function off. AFV mode is active when no levels keys are lit.
To make switches on all switching levels of a selected input source to a selected output destination, in
audio-follow-video (AFV) mode, use the control panel diagram below as a quick reference guide and
perform the following steps:
Proprietary Information of PESA
4-7
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
Select Desired Output Destination:
Click the DESTINATION Select Key on the panel graphic, the button will light.
Click the number key (1 – 32) corresponding to the Destination (destination group) you want to
select. When you select a destination, output ports defined through the destination group
assigned to the destination number key are selected; both the DEST key and the selected
number key should be lit.
•
Select Desired Input Source for Selected Destination:
Click the SOURCE Select Key on the panel graphic, the source button will light and the
number key corresponding to the source selected for the status level of the panel, and currently
routed to the destination you selected in the previous step will also light. If the button is
blinking, this indicates the switching levels are currently in a breakaway condition and one or
more of the levels is switched to a source that is different from the source assigned to the status
level of the panel.
Click the number key (1 – 32) corresponding to the Source (source group) you want to route to
the destination selected in the previous step.
When you select a source key, input signals defined through the source group assigned to the
source number key through router configuration are selected as the individual sources routed to
the destination output ports on all switching levels defined for the source group. When a source
is selected, the pushbutton lights and the switch immediately occurs.
When you are switching in AFV mode, Levels buttons will not be lit.
HOT-TAKE, BREAKAWAY SWITCHING
A breakaway switch allows you to switch source signals defined for one or more specific switching
levels of a selected source group to the output channels defined for the corresponding switching levels
of a selected destination group.
To perform a breakaway switch, use the control panel diagram below as a quick reference guide and
follow the steps below:
•
Select Desired Output Destination:
Click the DESTINATION Select Key on the panel graphic, the button will light.
Click the number key (1 – 32) corresponding to the Destination (destination group) to which
you want to route sources you specify in the breakaway selection. When you select a
destination, output ports defined through the destination group assigned to the destination
number key are selected; both the DEST key and the selected number key should be lit.
Proprietary Information of PESA
4-8
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
Select Desired Input Source for Selected Destination:
Click the SOURCE Select Key on the panel graphic, the source button will light and the
number key corresponding to the source selected for the status level of the panel, and currently
routed to the destination you selected in the previous step will also light. If the button is
blinking, this indicates the switching levels are currently in a breakaway condition and one or
more of the levels is switched to a source that is different from the source assigned to the status
level of the panel.
Click the Level key(s) corresponding to the switching level(s) for which you wish to select
source signal(s) to route to the destination output switching levels. You may select any number
of switching levels for the breakaway switch. The level button(s) light, and the illuminated
number key displays current status of switching levels - depending on which level buttons are
selected. Refer to Paragraph 4-6 for information on reading the status display.
Click the number key (1 – 32) corresponding to the Source (source group) you want for the
breakaway switch on the selected switching level(s) to the destination selected in the previous
step.
When you select a source key, input signals defined through the source group assigned to the
source number key are routed to destination outputs on only the switching levels defined for the
breakaway switch. When a source is selected, the pushbutton lights and the switch immediately
occurs.
PERFORMING A PRESET SWITCH
Preset switching mode is active when the PRESET button is illuminated – and remains the active mode
of the panel until the button is clicked again to cancel. Preset may be used for All-Levels or Breakaway
switches and allows you to pre-define a switch operation and execute the switch, when needed, by
clicking the TAKE button. Follow steps below to perform a breakaway switch:
•
Select Desired Output Destination:
Click the DESTINATION select key on the panel graphic, the button will light.
Click the number key (1 – 32) corresponding to the destination group for which you wish to
configure a preset switch, for example OUT1 corresponds to key 1; now both the DEST key and
the selected number key should be lit.
•
Place Panel in PRESET Switching Mode:
Click the PRESET pushbutton on the panel graphic, the key illuminates and the number key
select function (Dest./Source) changes to Source. The Source Select button lights and the
number key corresponding to the source currently routed to the destination you selected in the
previous step also lights.
•
Define Sources for PRESET Switch:
Following the same procedures used to select sources for an All-Levels or Breakaway switch,
use the number keys and level keys to define sources you wish to route to the selected
destination when the preset switch is initiated.
With Preset mode active, the switch does not occur as keys are clicked; however, the panel
status tally display changes to indicate pre-defined source for the preset switch.
Proprietary Information of PESA
4-9
PNET SOFT PANELS
Publication 81-9059-0686-0, Rev. A
March 2011
•
Initiate PRESET Switch:
Click the TAKE pushbutton on the panel to immediately perform the preset switch.
Preset remains the active operating mode of the panel until cancelled by the user.
When a preset switch is completed, and Preset is still the active mode of the panel, the channel
status prior to the switch is stored as the next preset definition and displayed as preset status by
the illuminated number key.
In essence, the preset mode may be used as a toggle function, allowing you to return to the
previous status of the channel, until a new preset switch is defined, or preset mode is cancelled.
Remember, when preset mode is active and you have entered a pre-set source definition, the
illuminated panel number key displays status of the preset source, NOT the currently active
source; and will continue to display the preset source until preset mode is cancelled.
•
Cancel PRESET Switching Mode:
When active, click the PRESET pushbutton on the panel to cancel the mode and return the
panel to Hot-Take mode. The illuminated number key displays the source currently routed to
the selected destination.
4.8
APPLYING DESTINATION PROTECT OR LOCK
Applying protection to a destination prevents another user or an accidental key click from switching the
current source selection. The Protect/Lock key is used to apply destination protection, and it also
provides a visual status of the current protection status of the selected destination. If the Protect/Lock
button is not illuminated, there is currently no active destination protection and the source selected for
the destination may be switched by any panel in the system allowed access to the destination.
There are two protection methods available, each is introduced below:
•
Destination PROTECT – A momentary click of the Protect/Lock button places the currently
selected destination in “Protect” mode, whereby the protected destination can still be switched
by the panel which originally placed the destination in “Protect” mode, but is “Locked” to all
other panels and users. When the destination is in Protect mode, the Protect/Lock button is
steadily illuminated. Clicking the Protect/Lock key toggles the protect mode of the selected
destination.
•
Destination LOCK – Clicking and holding the Protect/Lock button for approx. 2 seconds
places the currently selected destination in “Lock” mode (Lock/Protect Key Blinking). In Lock
mode the selected destination is “Locked” for all users and can not be switched to a different
source by any panel or other user without first unlocking the selected destination. Clicking the
Protect/Lock key toggles the protect mode of the selected destination.
Proprietary Information of PESA
4-10
Download PDF