ITEM
PART NO.
QTY
[]
A
B
C
D
E
F
56040800
56409232
56409495
56409538
56009018
56002708
56002098
1
1
1
2
2
2
2
DESCRIPTION
Instruction Sheet
Back-Up Alarm
Wire Assembly, Pigtail
Terminal Insulator
Scr, Hex Thd Form 1/4-20 x .75
Nut, Hex Nyl Loc 1/4-20
Washer, Flat
[ ] = Not Shown
1
2
3
4
See Figure 1. Slide one Terminal Insulator (C) onto each of the wires (one RED & one BLK) in the Wire Assembly Pigtail (B) as shown.
Remove one nut from each of the terminal studs on the Back-Up Alarm (A).
Connect the RED wire of the harness to the (+) positive terminal of the alarm, then connect the BLK wire to the (–) negative terminal on the alarm
using the nuts from the previous step.
Slide both terminal insulators down so that they completely cover the alarm terminal studs and nuts.
FIGURE 1
B
C
D
RED
F
A
E
BLK
© 2013 Nilfisk-Advance, Inc.
(page 1 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
LP & D CS7000 Hybrid, CS7000 Hybrid EcoFlex™ CS7000 B & CS7000 B EcoFlex™ INSTALLATION INSTRUCTIONS
WARNING!
TURN KEY OFF BEFORE SERVICING.
5
6
7
8
See Figure 2. Drain the Recovery Tank (L) and disconnect the squeegee hose from the tank. Release the Latch (1) and tilt the tank out and
disconnect the vacuum motor harness connector from the main harness. Disconnect the Cable Assembly (2) from the Recovery Tank (L) and lift
the tank up and off the Tank Pivots (3) and set aside. NOTE: The back-up alarm will be mounted using pre-drilled holes.
Mount the Back-Up Alarm (A) to the frame as shown using Screws (D) and Washers (F).
Locate the Connector from the main harness that will be located near the mounting location of the Back-up Alarm (A). The connector will have
one GRN/BRN and one GRAY wire going to it. Remove the plug from the connector and Plug the alarm harness into this connector.
Proceed to the next page for programming to recognize this kit. After programming, re-install the Recovery Tank (L) and reconnect the Cable
Assembly (2). Reconnect the vacuum motor harness connector to the main harness before latching the tank in the closed position. Reconnect
the squeegee hose to the Recovery Tank (L). Start the machine and test the back-up alarm for proper operation.
The alarm should sound in reverse only.
2
FIGURE 2
1
Squeegee Hose
L
Pre-drilled holes
Drain Hose
Tank Pivot
D
F
A
3
3
Tank Pivot
D
F
A
© 2013 Nilfisk-Advance, Inc.
(page 2 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
CS7000 PROGRAM CONTROLLER TO RECOGNIZE THIS KIT
1.
2.
3.
4.
5.
6.
7.
See Figure 3 Turn the Key Switch (3A) to the Off position.
Press and hold both Turn Signal buttons (3C and 3D) and turn the key switch On. Continue to hold both buttons for 2 seconds.
The hidden configuration menu will appear on the Display Screen (3B). Use the Scrub Pressure Increase (3E) and Scrub Pressure Decrease
(3H) buttons to scroll through the menus until “Back-up Alarm Installed” appears.
Press the One Touch Scrub button (3F) to enter the submenu.
Press the Scrub Pressure Increase button (3E) until “Installed” is shown on the display.
Press the One Touch Scrub button (3F) to save the setting, and then press the Solution On/Off button (3G) to exit the submenu.
Turn the Key Switch (3A) to the off position to exit the hidden menus.
FIGURE 3
3C
3D
3B
3E
3F
3G
3A
3H
© 2013 Nilfisk-Advance, Inc.
(page 3 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
Condor XL / ER1300, ER1600 INSTALLATION INSTRUCTIONS
WARNING!
TURN KEY OFF BEFORE SERVICING.
5
6
7
8
See Figure 4. Open the engine cover and locate the part of the frame where the back-up alarm will mount using the pre-drilled holes. NOTE:
The backup alarm mounts just to the left of the squeegee lift cylinder.
Mount the Back-Up Alarm (A) to the frame as shown using Screws (D) and Washers (F).
Locate the Wire Connector from the main wiring harness next to the hydraulic reservoir. The connector will have one GRN/BRN and one BLU/
BLK wire going to it. Plug in the alarm harness to this connector.
Proceed to Page 6 for programming instructions. After programming,
close the engine cover. Start the machine and test the back-up alarm
for proper operation.
The alarm should sound in reverse only.
FIGURE 4
A
F
D
© 2013 Nilfisk-Advance, Inc.
(page 4 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
SC8000 INSTALLATION INSTRUCTIONS
WARNING!
TURN KEY OFF BEFORE SERVICING.
5
6
7
8
See Figure 5. Open the engine cover and locate the part of the frame where the back-up alarm will mount using the pre-drilled holes. NOTE:
The backup alarm mounts just to the right of the hydraulic manifold.
Mount the Back-Up Alarm (A) to the frame as shown using Screws (D) and Washers (F).
Locate the Wire Connector from the main wiring harness next to the hydraulic reservoir. The connector will have one GRN/BRN and one BLU/
BLK wire going to it. Plug in the alarm harness to this connector.
Proceed to Page 6 for programming instructions. After programming,
close the engine cover. Start the machine and test the back-up alarm
for proper operation.
The alarm should sound in reverse only.
FIGURE 5
F
A
D
© 2013 Nilfisk-Advance, Inc.
(page 5 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
Condor XL / ER1300, ER1600 / SC8000 PROGRAMMING INSTRUCTIONS
1
2
3
4
5
Press and hold the Hazard (A) and Headlight Switches (B) simultaneously. Turn the Keyswitch (C) ON and wait until the Display (D) reads
“Configuration Menu” as shown.
Press the Side Broom Raise (E) or Lower (F) switches to scroll through the list of available options.
Once you see the appropriate option on the Display Panel (D) press the Scrub ON Switch (G) to enter the sub menu for that option.
Once in the option sub menu, press the Side Broom Raise (E) or Lower (F) switches to switch between “Not Installed” and “Installed” and then
press the Scrub ON Switch (G) at “Installed” to enable the option. NOTE: Pressing the Scrub OFF Switch (H) at any time will take you back to
the previous level in the menu.
Turn the Keyswitch (C) OFF.
MAIN MENU
CONFIGURATION MENU
Back-Up Alarm
Lights
OPTION SUB MENU
Lights
Not Installed
Installed
D
A
B
E
H
© 2013 Nilfisk-Advance, Inc.
G
(page 6 of 7)
F
C
8/03 revised 7/13 Form No. 56040800 REV D
Captor / CR 1100, 1200, 1400 INSTALLATION INSTRUCTIONS
WARNING!
TURN KEY OFF BEFORE SERVICING.
5
6
7
8
9
See Figure 6. Open the rear Door (G) and locate the Bracket (H) (part of the frame) where the back-up alarm will mount using the pre-drilled
holes.
Remove the (3) Screws (I) that secure the rear Panel (J). Carefully pull off the rear panel, remove the brake light bulbs from the panel by rotating
1/4 turn counterclockwise. Set the panel aside.
Mount the back-up alarm to the frame as shown using Screws (D), Washers (F) and Nuts (E).
Locate the Wire Connector (K) from the main wiring harness behind where the rear panel was. The connector will have one GRN/BRN and one
ORN wire going to it. Plug in the alarm harness to this connector.
Close the rear door. Start the machine and test the back-up alarm for proper operation. Alarm should sound in reverse only. Once it is confirmed
that the alarm works, reinstall the light bulbs to the rear Panel (J) and secure panel with Screws (I).
FIGURE 6
K
I
J
D
F
FRONT
G
B
E
H
A
Diesel, LPG, Petrol model shown, Battery models look similar and have same installation.
© 2013 Nilfisk-Advance, Inc.
(page 7 of 7)
8/03 revised 7/13 Form No. 56040800 REV D
Download PDF
Similar pages