Smart Online 3-Phase UPS Systems
3-Phase on-line, double-conversion protection for mission critical applications
Model #: SU30K3/3
30,000 VA (30kVA) tower UPS
3-phase hardwire input and output (120/208V AC). Wide input voltage correction range (88144V AC/166-250V AC)
IGBT technology
Zero transfer time, on-line, double-conversion operation
Expandable runtime with additional external battery modules. Custom battery configurations
are available
3 communication ports, SNMP card slot and EPO jack
DESCRIPTION
Tripp Lite’s SU30K3/3 Smart Online 3-Phase Intelligent, True On-Line UPS System provides mission-critical equipment with the highest level
of power protection available. Large capacity 30,000 VA / 24,000 watt power module continually converts incoming AC power into filtered DC
power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero
transfer time offers compatibility with all equipment types. IGBT technology produces output power with <3% THD (total harmonic distortion),
allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildlyfluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output
connections support a variety of permanent or PDU style power connections. SU30K3/3 features 120/208V AC, 3-phase, 4-wire (plus ground),
wye input and output. It also features a wide input voltage correction range: 88-144/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable).
SU30K3/3 includes a power module and an external battery module, both in tower format cabinets. Battery support can be extended with
additional external battery modules. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected
equipment by safely passing through AC power when the power module requires maintenance. Three built-in communication ports (RS-232,
contact closure and AS-400) work with included PowerAlert Software to simultaneously provide shutdown commands and reporting on
multiple servers without the need for costly accessories. An accessory slot accepts an optional internal SNMP card (model #
SNMPWEBCARD) for remote shutdowns, reboots and more. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to
utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass
output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination
LCD/LED display alerts users to a variety of UPS operational modes and conditions. A 1-year limited repair or replacement warranty is
included. A start-up service program is recommended to enhance the reliability of the installation.
KEY BUYING POINTS
True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
30,000VA/24,000 watt power capacity with 3-phase, hardwire 120/208V AC input/output connections
Features a wide input voltage correction range 88 - 144/166 - 250V AC
Standard included battery module provides 18 minutes runtime at half load (12,000 watts) and 6 minutes runtime at full load (24,000
watts)
3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands
Expandable runtime with multiple external battery modules (model # BP240V33)
3 communication ports (RS-232, contact closure and AS-400)
Slot for optional SNMP card ( model # SNMPWEBCARD)
Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing
through AC power when the power module requires maintenance
Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data
retrieval
Emergency Power Off button turns UPS output OFF and disables Bypass output
PowerAlert Universal UPS Power Management Software and 6 ft. communication cable included
1-year limited repair or replacement warranty
Start-up service program is recommended to enhance the reliability of the installation
Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities
Combination LCD/LED display
TYPICAL APPLICATIONS
Ideal for protecting critical 120/208V equipment in computing, networking and telecommunications environments.
OPTIONS & ACCESSORIES
SNMP accessories: SNMPWEBCARD, ENVIROSENSE
AS400/iSeries Shutdown Cable Kit: AS400 CABLE KIT
External battery pack: BP240V33
External Battery Module Daisy Chain Accessory: BPMULTI (One required for 1-3 additional battery packs; two required for 4-7
additional battery packs; three required for 8-11 additional battery packs, etc.)
Maintenance Bypass Panel: SU30KMBP
SYSTEM REQUIREMENTS
SU30K3/3 UPS System (power module and battery module)
PowerAlert Software and cabling
Warranty information
Instruction manual
COMPLETE SPECIFICATIONS
SYSTEM OVERVIEW
System overview:
Online, double conversion tower UPS system continuously maintains near-perfect output
power for critical networking and telecommunications equipment. Completely regenerates
input power into perfectly regulated sine wave output free of harmonic distortion, fast
electrical impulses and frequency fluctuations. A 3:1 crest factor safely supports a variety of
equipment. Extremely efficient operation saves money by lowering electricity consumption.
Hardwire 120/208V AC 3-Phase, 4-Wire (plus ground), wye input and output connections.
Wide input voltage correction range: 88-144 / 166-250V AC. Includes a power module, an
external battery module, manual bypass switch (for 100% availability during maintenance),
three communication ports (RS-232, contact closure and AS-400), PowerAlert Software and
cabling, SNMP card slot, a Battery Start Switch (for cold restarts), an Emergency Power Off
button, an EPO port and combination LCD/LED display.
Voltage compatibility:
120/208V AC, 3-phase, 4-wire (plus ground), wye
Frequency compatibility:
50/60 Hz (auto-selectable)
OUTPUT
Output volt amp capacity (VA):
30,000 (30kVA)
Output watt capacity (watts):
24000
Output nominal voltage:
120/208V AC, 3-phase, 4-wire (plus ground), wye
Output voltage regulation:
Maintains pure sine wave output at all times, regulated within 2% of nominal output voltage,
less than 3% total harmonic distortion (using IGBT Inverter)
Output frequency regulation:
Regulates line frequency at 50 or 60 Hz, +/- 3 Hz
Outlet quantity / type:
Hardwire
INPUT
Maximum input amps:
90A
Input connection type:
Hardwire
Recommended electrical service:
120/208V AC (3-Phase, 4-Wire, wye)
BATTERY
Full load runtime:
Included batteries: 6 min. (24,000 watts). Runtime can be extended with additional
BP240V33 battery modules.
Half load runtime:
Included batteries: 18 min. (12,000 watts). Runtime can be extended with additional
BP240V33 battery modules.
Expandable battery runtime:
Supports extended runtime with optional external battery modules (model # BP240V33)
DC system voltage:
240V DC
Typical battery lifespan:
3 - 6 years, depending on usage
Battery recharge rate:
2 - 4 hours to 90%
VOLTAGE REGULATION
Voltage regulation description:
On-line, double-conversion process gives this UPS the ability to maintain output voltage
within +/-2% of nominal voltage at all times
Overvoltage correction:
Maintains continuous operation without using battery power during overvoltages to 144 /
250V AC (3-Phase, 4-Wire, wye), reducing output within 2% of nominal
Brownout correction:
Maintains continuous operation without using battery power during brownout / undervoltage
conditions to 88 / 166V AC (3-Phase, 4-Wire, wye)
LEDS ALARMS & SWITCHES
Front panel LEDs:
7 LED DISPLAY: AC input, bypass input, AC-DC charger, DC-AC inverter, AC output,
bypass operation and battery operation. SELECTABLE LCD DISPLAY: indicates a wide
range of UPS operational and fault/warning conditions including operational mode,
alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage
and more.
Alarms:
Alarms warn against a variety of operational conditions: low battery, overload, shutdown,
bypass and more
Switches:
“ON” button turns UPS’s inverter ON. “OFF” button turns UPS’s inverter OFF. “Select” Button
browses through items displayed on LCD screen. “Enter” button selects items displayed on
LCD screen. “Select” and “Enter” buttons used simultaneously mute UPS alarms. “Battery
Start” Switch cold starts the inverter. “Emergency Power Off” button turns UPS output OFF
and disables Bypass output. “Manual Bypass” switch bypasses the UPS’s inverter during
maintenance.
SURGE / NOISE SUPPRESSION
AC suppression response time:
Instantaneous
EMI / RFI AC noise suppression:
Yes
PHYSICAL
Shipping weight (lbs):
941 (total of Power Module - 330 - and Battery Module - 611)
Shipping weight (kg):
427 (total of Power Module - 149 - and Battery Module - 278)
Unit weight (lbs):
813 (total of Power Module - 238 - and Battery Module - 575)
Unit weight (kg):
370 (total of Power Module - 108 - and Battery Module - 262)
Unit Dimensions (HWD/in):
Power Module (34 x 15 x 26), Battery Module (20 x 18 x 36)
Unit Dimensions (HWD/cm):
Power Module (87 x 38 x 66), Battery Module (51 x 45 x 91)
Shipping Dimensions (HWD/in):
Power Module (44 x 21 x 32), Battery Module (23 x 24 x 40)
Shipping Dimensions (HWD/cm):
Power Module (112 x 54 x 82), Battery Module (57 x 61 x 100)
Material of construction:
Steel
Form factors supported:
Tower
Cooling method:
Built-in cooling fans
Battery Access:
External Battery Module can be hot-swapped with a replacement Battery Module
ENVIRONMENTAL
Operating Temperature:
+32 to +104 degrees Fahrenheit, 0 to +40 degrees Celsius
Storage Temperature:
-36 to +104 degrees Fahrenheit, -20 to +40 degrees Celsius
Relative Humidity:
5 to 95%, non-condensing
COMMUNICATIONS
Network monitoring port:
Includes 3 built-in communications ports (RS-232, contact closure and AS-400)
Software and cabling included:
Includes PowerAlert UPS monitoring software for all common network and standalone
operating systems. Cabling included.
SNMP compatibility:
Built-in accessory slot accommodates internal SNMP card (model # SNMPWEBCARD) and
other network accessories
LINE / BATTERY TRANSFER
Transfer time from line power to battery
mode:
Zero transfer time. True on-line UPS continuously converts incoming AC to DC, then back to
AC. When line power is interrupted, UPS maintains continuous output from battery reserves
with absolutely no disruption in output AC power.
Low voltage transfer to battery power:
Maintains continuous operation during undervoltages as low as 88/166V AC (3-Phase, 4Wire, wye). Below this point, output is maintained utilizing battery reserves.
High voltage transfer to battery power:
Maintains continuous operation during overvoltages as high as 144/250V AC (3-Phase, 4Wire, wye). Above this point, output is maintained utilizing battery reserves.
CERTIFICATIONS
Certifications:
UL, cUL, NOM, FCC Class A
WARRANTY
Optional coverage:
2-year, 3-year and 4-year extended warranties. Contact Tripp Lite.
Product warranty:
1-year limited repair or replacement warranty is included. Start-up service program is
recommended.
SPECIAL FEATURES
EPO port:
Includes dedicated EPO (emergency power off) interface and cabling
Cold Start:
Yes, inverter can be cold-started (with use of Battery Start Switch) to enable temporary AC
output during a power failure
Appearance:
Attractive black steel tower housing
BATTERY PACK ACCESSORY (optional)
Battery Pack Accessory (optional):
BP240V33 (optional)
The policy of Tripp Lite is one of continuous improvement.
Specifications are subject to change without notice.
Therefore, your product may vary slightly from what is currently listed.
© 2006 Tripp Lite. All Rights Reserved.