cqube se20 barista - Crem International

CQUBE SE20
BARISTA
USER MANUAL
UM_EN
Part No.: 1764020_02
CONTENT
CQube SE20 BARISTA
CONTENT......................................................................................................................................................... 2
GENERAL............................................................................................................................................................ 4
Introduction...............................................................................................................................................................4
Warnings.....................................................................................................................................................................4
Precautions.................................................................................................................................................................4
Intended use...............................................................................................................................................................4
Facts & weight............................................................................................................................................................5
OVERVIEW OF COMPONENTS......................................................................................................... 6
Front exterior..........................................................................................................................................................6
Front interior.............................................................................................................................................................7
Button functions........................................................................................................................................................8
User card....................................................................................................................................................................9
INSTALLATION AND START-UP...................................................................................................... 10
Connecting CQube SE to BARISTA module................................................................................................... 10
Positioning............................................................................................................................................................... 12
Machine startup procedure................................................................................................................................. 12
Fill ingredient canister and bean hopper.......................................................................................................... 13
OPERATION.................................................................................................................................................. 14
Brewing a cup of coffee........................................................................................................................................ 14
CLEANING PROGRAM.......................................................................................................................... 15
Clean brewer.......................................................................................................................................................... 15
Clean mixer............................................................................................................................................................. 16
Clean valves............................................................................................................................................................. 17
Daily milk clean....................................................................................................................................................... 18
Rotate brewer........................................................................................................................................................ 19
Rinse brewer........................................................................................................................................................... 20
Backflush milk system........................................................................................................................................... 21
CLEANING AND CARE......................................................................................................................... 22
Weekly cleaning...................................................................................................................................................... 22
Disassemble the espresso group........................................................................................................................ 22
Cleaning the espresso group............................................................................................................................... 23
Reassemble the espresso group......................................................................................................................... 24
Disassemble mixing system................................................................................................................................. 25
Wash these parts................................................................................................................................................... 26
Reassemble mixing system ................................................................................................................................. 26
2
CONTENT
CQube SE20 BARISTA
Clean fridge and milk container.......................................................................................................................... 27
Reset counter for milk cleaning.......................................................................................................................... 28
Replace the milk cleaning bottle......................................................................................................................... 29
Empty drip trays and containers......................................................................................................................... 30
Exterior cleaning.................................................................................................................................................... 31
MESSAGE SHOWN ON DISPLAY................................................................................................... 32
PROGRAMMING........................................................................................................................................ 33
Activate programming with the user card....................................................................................................... 33
How to upload new recipe into machine......................................................................................................... 34
Drink menu options.............................................................................................................................................. 35
Clean machine........................................................................................................................................................ 36
Counters.................................................................................................................................................................. 37
DIMENSION SKETCH.............................................................................................................................. 39
CQube SE20 BARISTA ........................................................................................................................................ 39
CQube SE20............................................................................................................................................................ 40
BARISTA ................................................................................................................................................................. 41
Some important information may appear in textboxes seen below
IMPORTANT!
INFO.
CAUTION!
INFO.
More INFO.
Note
INFO.
3
GENERAL
CQube SE20 BARISTA
Introduction
Thank you for choosing a CQube SE20 BARISTA espresso vending machine.
We hope you enjoy it !
Read the user guide before using the machine.
This guide contains important instructions for
proper and safe use of the vending machine.
Always keep this guide close at hand for future
reference.
Warnings
Never immerse the machine, plug or mains
cable in water because there is a danger of
electric shock.
The appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning the use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure they
do not play with the appliance.
Do not use the machine if the mains cable, plug
is damaged or the machine has fallen down.
If the mains cable is damaged it must be
replaced by the manufacturer, service agent or
similarly qualified persons in order to avoid a
hazard.
Only plug the machine into a properly installed
earthed safety socket whose line voltage
matches the technical data for the machine.
Precautions
Do not use the machine outdoors so it can be
exposed to weather (rain, snow, frost). It will
cause material damage to the machine.
Do not try to open the machine or repair it in
any way. To avoid danger only have the machine
repaired in a technical workshop, Service
Centre or by a qualified person.
Remove the mains cable from the socket when
the machine is not in use for longer periods. To
do this, pull the plug not the cable.
This appliance must be placed in a horizontal
position which is resistant to any water that
may leak.
Place the machine out of the reach of children.
Position the mains cable so that people cannot
trip over it. Keep it away from sharp edges and
heat sources.
The new hose-sets supplied with this appliance
are to be used, old hose-sets must not be reused.
This appliance is not suitable for installation in
an area where a pressure washer could be used.
This appliance must not be cleaned by a
pressure washer.
Intended use
This appliance is intended to be used in
household and similar applications such as:
- Staff kitchen areas in shops.
- Offices and other commercial working
environments.
- On agricultural estates.
- By clients in hotels, motels and other
residential type environments.
- Bed and breakfast type environments.
4
For the optimal performance of the machine
these parameters shall not be exceeded:
- Maximum permissible inlet water pressure :
800KPa (8Bar)
- Minimum permissible inlet water pressure:
200KPa (2Bar)
- Maximum working temperature: 40°ºC
- Minimum working temperature: 10°ºC
GENERAL
CQube SE20 BARISTA
Facts & weight
FACTS
CQUBE SE20 BARISTA
Drink options
1-12
Function for selecting jug
No
Grinder type
2 x EK-7
Number of bean hoppers
2
Number of ingredient canisters
1
Brewer type
Espresso
Touchscreen
Standard
Espresso pump type
Vibration pump
Milk container
5L
Drip tray size
0.5L
Milk waste container size
1.1L
Waste box
~ 200 espresso pucks
Base cabinet
Option
Tank volume
1.8L
Espresso boiler
0.7L
Power supply
Water connection
Water filter
220-230VAC/2200W 50-60Hz
1/2” external thread
Option
Height, Width, Depth
MODEL/NAME
818, 562, 532mm
WEIGHT
CQube SE20
37kg
BARISTA
37kg
5
OVERVIEW OF COMPONENTS
CQube SE20 BARISTA
Front exterior
Bean hoppers
Touchscreen
e
Drink menu
ter
ESPRESSO DRINKS
Start energy save mode
Door lock
Smart-card reader
Outlet hot drinks
Cup shelf
Drip grids
Drip tray
Door handle
Barista unit
6
OVERVIEW OF COMPONENTS
CQube SE20 BARISTA
Front interior
Chocolate canister
Bean hoppers
Bean stops
Grinders
Grinder adjustment wheels
Grinder outlets
Espresso group
Mixing bowl
Milk fridge
Drink outlets
Milk waste container
Waste box
Ingredient canisters
DETAIL
INGREDIENTS
Hopper
Beans
Hopper
Beans
----
Canister
Chocolate
130mm
Milk
115mm
320mm
Container
WIDTH
DEPTH
----
----
HEIGHT CAPACITY
CUPS/UNIT
----
1.25kg
~175 cups
----
----
1.25kg
~175 cups
180mm
135mm
1.2kg
~65 cups
190mm
5L
~70 cups
7
OVERVIEW OF COMPONENTS
CQube SE20 BARISTA
Touchscreen navigation
Button functions
Choose drink type
by pressing the icon
on the touchscreen.
Double Espresso
Coffee
Double Espresso
Coffee
Cappuccino
Cafe Latte
Cappuccino
Cafe Latte
Choco-milk
Pitcher Milk
Hot Water
Double Espresso
START
BACK
Press the BACK button if you want to leave the submenu and go back in the
menu.
ENTER
Press the ENTER button to confirm a set value or a setting. Confirm the new
setting by pressing the E-button.
START
STOP
Press START button to confirm drink choice.
Press the STOP button if you want to return to the start menu.
Press the MINUS button for choosing Strength / Volume of the drink or
decrease a value in service menu.
Press the PLUS button for choosing Strength / Volume of the drink or increase a
value in service menu.
To activate energy saving mode press the power icon on the display.
ENERGY SAVING MODE
8
The machine reduces the temperature in the water tank to 650C.
OVERVIEW OF COMPONENTS
CQube SE20 BARISTA
User card
Face
Back
User card
Is used for cleaning and see counter settings. User card is supplied by your dealer.
Insert the user card with the chip forward
as in the figure A.
The display will show the service menu, you
can now browse forward by touching these
icons.
A
To use the machine again remove the user
smart card and store it in a safe place.
9
INSTALLATION AND START-UP
CQube SE20 BARISTA
Connecting CQube SE to BARISTA module
01
A
B
A
D
B
C
C
D
C
onnect the communication cable and water tubes correctly as figure. Don’t mix the position of the A,
B,C and D. Otherwise the machine will not function properly.
10
INSTALLATION AND START-UP
CQube SE20 BARISTA
Connecting CQube SE to BARISTA module
02
03
E
E
Guide the milk tube from the outlet beam
through the holes in side panel of the machine
and barista unit. Connect it to the mixer bowl.
04
Slide the front and back profiles in the middle
of these two machine (E), push the profiles all
the way down.
05
F
G
H
G
Assemble the top lid by pressing the guide pins
into the profiles.
Connect the power cords (G,H) and water inlet
hose (F) as figure.
11
INSTALLATION AND START-UP
CQube SE20 BARISTA
Positioning
Place the machine on a flat horizontal surface that will
support the weight of the machine.
minimum 10cm
After you have connected all water tubes and
assembled the front and back profiles, push machine
into position according to the picture.
Note
Make sure air is able to circulate behind
the machine (minimum 10cm).
Machine startup procedure
A
B DC
B
Connect the water hose to the cabinet of the CQube
SE20 machine(A).
Connect the supplied water hose to the cold water
connection using a ½’’ R-connection. When pushing
the machine into position make sure there is no
interference to the hose to ensure proper water
flow.
If the inlet hose is new, flush the system with water
first to remove copper shavings. These can damage
the inlet valve.
The new tube set supplied with the appliance must be
used. Old tubes may not be reused. Connection to a
closable valve is recommended.
Min. water pressure: 2 bar (200kPa).
Max. water pressure: 8 bar (800kPa).
Open the water tap.
Connect the mains cable from CQube SE20 to Barista (B) and mains cable (C) to a earthed wall socket.
Switch on the power switch (D) on the rear of the machine.
The display indicates
Low Water Level
Press Enter Key
Press the ENTER button.
The main water tank will now automatically fill with 1.8 litres of water. Simultaneously the espresso water
system will start to fill up. When espresso system is full, some water will be dispensed into the drip tray.
Once the heating is complete, “Low temperature” text will disappear from the display. The icons will be
unlocked and the banner will alternate between “ESPRESSO DRINKS” and “SELECT PRODUCT”.
Note
12
Default temperatures:
Water tank = 96°C, Espresso boiler =98°C, Milk heater 1 = 70°C, Milk heater 2= 65°C
INSTALLATION AND START-UP
CQube SE20 BARISTA
Fill ingredient canister and bean hopper
01
Open the door.
03
02
Lift the lid and fill the bean hopper with freshly
roasted coffee beans without additives. also lift
the barista lid and fill chocolate powder.
When filling the chocolate powder, keep the
opening of the canister chute upwards.
04
A
B
Open the fridge door and draw out the milk
container, fill up the container with fresh milk.
Open the bean stop (A) on the bean hopper,
Ensure that the opening of the canister chutes
point down toward the mixing bowl(B).
Close the door, the machine is ready to use.
13
OPERATION
CQube SE20 BARISTA
Brewing a cup of coffee
Double Espresso
Coffee
Double Espresso
Coffee
Cappuccino
Cafe Latte
Cappuccino
Cafe Latte
Choco-milk
Pitcher Milk
A
Hot Water
Double Espresso
START
Place a cup under the outlet for hot drinks. (A)
Choose drink by pressing the drink button on the screen.
Confirm drink by pressing the START button
The display shows:
and the cup light goes on.
Wait until the cup light switches off and the animation
disappeared from the display before removing the cup.
14
has
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Clean brewer
B
Total cleaning time
about 5 minutes.
Espresso cleaning
tablets are avalible
from your dealer:
Part No.: 1104171
A
IMPORTANT!
After cleaning of the
brew mechanism is
completed, dispense
a cup of coffee and
discard it to remove
cleaning agent
remains in the
filter and brew
chamber.
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Put a container that holds at least 1 litres under the outlet for hot drinks.
Press button
on the cleaning panel. (See fig. B)
Display indicates:
Place jug
Press ENTER to start
Put a cleaning tablet in brewmechanism. (See fig. C)
Press
on the cleaning panel to start the cleaning process.
Enter
Display indicates:
Preparing Brewer
Please Wait.
Cleaning Unit
Display indicates:
Time Left 60 seconds
seconds.
Fig.C
Display indicates:
Rinsing Brewer
Cycles left 3
Display indicates:
Cleaning hot key
The machine counts down from 60
when the cleaning is complete.
Close the door to return to normal mode.
Note
When the cleaning tablet has been added, the process must not
be interrupted but be allowed to run its course.
15
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Clean mixer
Cleaning means
rinsing with water
and rotating the
whipper.
A
B
Cleaning of the
mixing bowl should
be performed once
per day.
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Put a container that holds at least 0.5 litres under the outlet for hot drinks.
Press button
on the cleaning panel. (See fig. B)
The machine will now clean the mixing bowl for 5 seconds.
Close the door to return to normal mode.
Note
16
Repeat the cleaning procedures 2-3 times to get a better
cleaning effect.
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Clean valves
B
Cleaning entails
that the valves
“knock” off any
lime scale and
other particles
that may get stuck
in the cylinders
and flushing them
with water.
A
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Put a container that holds at least 0.5 litres under the outlet for hot drinks.
Press button
on the cleaning panel. (See fig. B)
The machine will now clean the dispenser valves for 5 seconds.
Close the door to return to normal mode.
Note
Repeat the cleaning procedures 2-3 times to get a better
cleaning effect.
17
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Daily milk clean
A
This cleaning is
also scheduled to
run every night at
03:00
B
Milk system cleaning
liquid are avalible
from your dealer:
Part No.: 1104165
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Press button
on cleaning panel inside of the door (See fig. B)
Filling System..
this takes approx 10-15sec
Cleaning System
Time Left: 60s
machine counts down from 60s
Air Drying System Machine counts down from 120s
Time Left: 120s
When cleaning is completed display shows Cleaning Hot Key
Close the door to return to normal mode.
Note
18
Repeat the cleaning procedures 2-3 times to get a better
cleaning effect.
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Rotate brewer
B
This function
can be used
to position the
espresso brewer
so it’s easier to
remove and get
access to the
filter in bottom of
brew cylinder for
cleaning.
A
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Press button
on the cleaning panel. (See fig. B)
When machine is fitted with espresso brewer this function is used as “Push
and Hold”. Brewer will rotate as long as you keep the button pressed.
Close the door to return to normal mode.
Note
If you don’t rotate the espresso brewer in correct position
before exiting the cleaning mode. First drink you make after this
may not contain any powder in the chamber, depending on the
brewer position. Second drink will be dispensed normally.
19
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Rinse brewer
B
A
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Put a jug or container for at least 200ml at the brewer outlet.
When machine is fitted with espresso brewer it will close the brewer and rinse the unit with 50ml hot water, then it will go back to home position.
Press button
on the cleaning panel to start rinse. (See fig. B)
When rinsing is complete you can repeat this process 2-3 times when
Cleaning Hot Key is shown in display to get a better effect.
Close the door to return to normal mode.
20
CLEANING PROGRAM
CQube SE20 BARISTA
Detailed cleaning instructions
Backflush milk system
B
This cleaning
should be
preformed
when changing
milk bag or milk
container.
A
Open the door.
Press ENTER on the cleaning panel inside the door. (See fig. A)
Cleaning Hot key appears on the display (Cleaning panel is now active).
the display shows: Cleaning Hot Key
Open cooler in Barista unit and make sure milk bag or milk container is
empty.
Press button
on the cleaning panel. (See fig. B)
The cleaning will start and backflush the milk system with hot water to
primarily clean the direction valve inside the cooler. The waste water from
this cleaning will be automatically flushed into milk bag or milk container.
The cleaning process takes about 10sec.
Repeat this process 2-3 times when Cleaning Hot Key is shown in display to
get a better effect.
When the backflush is completed, dispose of the milk bag or clean milk
container before refilling with new milk.
Close the door to return to normal mode.
21
CLEANING AND CARE
CQube SE20 BARISTA
Weekly cleaning
Disassemble the espresso group
01
02
Open the door and remove the waste box.
03
Press down the safety ring on the connector
simultaneously pull the teflon tube straight up.
05
Loosen the fixation screw at the bottom of
the brewer.
04
ut your hand according to the picture, push
P
up and forward at the same time until the
brewer is detached at the back. then pull it
straight out.
L oosen the brewer tube from the outlet by
pulling it straight out.
22
CLEANING AND CARE
CQube SE20 BARISTA
Cleaning the espresso group
First, remove the espresso group from the machine as explained earlier in this
manual. Then proceed to clean it with neutral detergents (avoid solvents that
could damage paint or plastics). Disinfectant products as chlorine-detergents are
preferred. (See Fig.1-2)
The producer declines all responsibilities due to the use of caustic/aggressive
detergents.
Fig. 1
Fig. 2
IMPORTANT!
Fig. 3
Turn the group upside down to clean the upper filter(A)
of the espresso chamber. (See fig. 3)
A
Whenever the quality or speed of the outgoing
espresso changes, clean the upper filter thoroughly.
Note It will be very likely partially clogged with tiny
coffee particles. Cleaning this filter will solve the
speed and quality issues.
After this, proceed to clean the remaining surfaces of the group.
(See Fig.4)
Fig. 4
Dry up the brewer using a soft rag. turn the brewer upside down and shake it to force as much water out as possible. Make
sure to pay extra attention when drying up the powder funnel
located above the brew chamber, as this is the one receiving the
grinded coffee. If this funnel is humid, it may cause the funnel
clog with coffee powder.
Once all cleaning is completed and the brewer heve been put back in place, we recommend to perform an rinse brewer cycle. (See page 20)
23
MAINTENANCE AND CARE
CQube SE20 BARISTA
Reassemble the espresso group
01
02
“Click”
Replace the brewer in front of the gearbox.
03
Attach top part at the back of the brewer to
the hooks on the gearbox. push in the bottom
part untill a click is felt.
04
A
Fasten the fixation screw.
05
B
Reconnect inlet(A) and outlet(B) tubes.
Replace the waste box, the brewer is ready
to use again.
24
CLEANING AND CARE
CQube SE20 BARISTA
Weekly cleaning
Disassemble mixing system
01
Pull out the outlet hose.
Turn the mounting plate lever anticlockwise.
02
03
Loosen the mixing bowl by pulling it straight out.
Loosen the whipper by pulling it straight out.
04
06
05
Loosen the mounting plate. Turn the lever
anticlockwise, until it stops.
Pull the mounting plate straight out.
Reassemble mixing system
See the next page
25
CLEANING AND CARE
CQube SE20 BARISTA
Weekly cleaning
Wash these parts
Mixing Bowl
Mounting Plate
Whipper
Clean with a moist
cloth and wipe dry.
All parts must be dry before reassembly.
Reassemble mixing system
01
02
A
Check all seals(red) before
reassembly of parts.
03
The flat side of the whipper shaft must correspond
with the marked arrow(A) on the whipper.
To fit the whipper push onto the shaft until a click
sound can be heard. It is only possible to assemble
the whipper in one way.
Fix the mixing bowl and condensation trap. Pushfit the mixing bowl and fix with lever.
04
Connect the outlet hose.
Note
26
Ensure that all water hoses have been
connected and fitted.
CLEANING AND CARE
CQube SE20 BARISTA
Clean fridge and milk container
This cleaning should be preformed
at least once a week.
1
Milk container
Open the fridge door and take out the milk container.
2
Milk waste container
Clean inside of the fridge with a soft cloth.
Clean the milk container and milk waste container with a brush under running water.
27
CLEANING AND CARE
CQube SE20 BARISTA
Reset counter for milk cleaning
Reset Soldout
Double Espresso
Coffee
Double Espresso
Coffee
Cappuccino
Cafe Latte
Cappuccino
Cafe Latte
Choco-milk
Pitcher Milk
Fig. B
Milk Cleaner
Hot Water
Milk Cleaner
Bottle Replaced
Milk Cleaner
Replace Bottle
Fig. A
Fig. C
ENTER
After 15 daily milk cleaning cycles the cleaning bottle needs to be replaced.
There is a counter that will show a message on the screen when this is due.
The screen will indicate:
Milk Cleaner
Replace Bottle
(Fig. A)
Open the door and replace the milk cleaning bottle according to the
instructions on page 29.
When the bottle is replaced the counter needs to be reset. To do this press
Milk Cleaner
button that is visible when machine door is open (Fig.B).
Milk Cleaner
When you press the button a message will indicate: Bottle Replaced .
The counter is now reset. (Fig. C)
Close machine door to return to normal mode.
28
CLEANING AND CARE
CQube SE20 BARISTA
Replace the milk cleaning bottle
01
02
A
Open the door and remove the waste box.
03
Place the bottle into the original position.
B
Take out the bottle and unscrew the old
bottle (A). Keep the lid and tube connected to
the machine, replace with a new bottle (B)
04
Replace the waste box to the original position
and close the door to return to normal mode.
29
CLEANING AND CARE
CQube SE20 BARISTA
Empty drip trays and containers
Empty Drip Tray
ENTER
Door
A
If the madchine indicate Emty Drip Tray (A), there is
three different trays that might need to be emptied.
Check the containers shown below and empty the
water.
Grab the drip tray with your hands and
simply pull it straight out.
Overpressure Water
Open the machine door, first take out the
waste box. Grab the metal box handle with
your finger and pull it straight out.
Milk Waste
Open the barista door, grab the
container with your hand and lift it out.
30
CLEANING AND CARE
CQube SE20 BARISTA
Exterior cleaning
e
ter
ESPRESSO DRINKS
Exterior cleaning when necessary
To clean the exterior of the machine, use a soft cloth
and liquid cleaning agent that is non-abrasive.
If using machine equiped with touchscreen do not
spray cleaning liquid directly on the display. Use only
LCD screen cleaner designed for touchscreen cleaning.
Clean the bean hopper
Close the bean stop.
Lift the bean hopper up to remove it. Use a soft cloth
and liquid cleaning agent that is non-abrasive.
Note Ensure that the bean hopper is completely dry
before refitting.
Clean the grinder
Cleaning of grinder shall be performed once per month
in conjunction with technical maintenance.
31
MESSAGE SHOWN ON DISPLAY
Message on display
CQube SE20 BARISTA
Indication
Energy Saving Mode
The machine is in energy saving mode.
Not Available
Drink can not be selected as jug.
Heating Water
Please Wait...
Low temperature in the water tank, the machine is heating up
(blocked).
Low Water Level
Press Enter Key
Low water level in water tank. Press enter key to start filling up
the water tank.
Filling Water
Please Wait...
The machine is filling water.
Warning
Low Temperature
Temperature is low, It is still possible to dispense drink.
Low temperature
Blocked
Temperature is low, the machine is blocked.
Empty Drip Tray
The drip tray or milk waste container is full of water.
Low Water
Level Blocked
The water level in the water tank is low, it is not possible to
dispense drink.
Check
Water Supply
The water has not reached the correct level in the water tank,
check the water inlet hose, restart the machine.
Empty Waste Box
The waste box is full, open the door and empty out the grounds.
When closing the door, press E to reset the counter. Selectable in
main program.
Change Brewer Filter
The brewing filter is clogged. The filter needs replacing or to be
cleaned.
Bev. Disabled
The drink has been disabled.
Door Open
The door is open.
Change
Water Filter
The water filter needs replacing, press the button E to reset the
counter.
32
PROGRAMMING
CQube SE20 BARISTA
Activate programming with the user card
Insert user card in the card reader (A)
A
The display will look like this:
33
PROGRAMMING
CQube SE20 BARISTA
How to upload new recipe into machine
A
B
USB
Insert service card(A) and open machine door.
Insert the USB flash drive into the USB connection(B) inside
the door.
Note
C
The machine must show the service menu before you
insert the USB.
The install screen will now appear (Fig. 1)
When machine have scanned the flash drive (takes around 5
seconds) press the
Install button.(C)
Browse through the recipes with the Next and
Prev
Fig.1 buttons(D). Drink menus and their recipe names can be found
on page 35.
Select your desired recipe and press Install button.(E)
D
Machine transfers the new recipe and restarts automatically.
Keep the service card inserted while the machine is restarting.
When the machine has restarted and entered the service
menu, you may take out the USB flash drive and close the door
to start using the machine.
D
Note
E
34
When updating to a special user interface with animation
during drink dispensing, the first cup after machine start up
may take 30-60 seconds before it starts.This happens because
the software must load all images of the animation into the
memory.
PROGRAMMING
CQube SE20 BARISTA
Drink menu options
Espresso
Double Espresso
Coffee
Cafe Latte
Latte Macchiato
A
Drink menu 1
B
Americano
Recipe file name: 422_x_CQube_SE20_Barista.mef
Using left grinder:
Cappuccino
Choco-milk
Pitcher Milk
Hot Water
Double espresso
Coffee
Cappuccino
Café Latte
Latte Macchiato
Using right grinder:
Coffee
Americano
B
ESPRESSO DRINKS
A
Drink menu 2
Double Espresso
A
Coffee
Double Espresso
Cafe Latte
Cappuccino
B
Coffee
Recipe file name: 423_x_CQube_SE20_Barista.mef
Using left grinder:
Cappuccino
Choco-milk
Pitcher Milk
Using right grinder:
Cafe Latte
Hot Water
ESPRESSO DRINKS
Double espresso
Coffee
Cappuccino
Café Latte
A
Double espresso
Coffee
Cappuccino
Café Latte
B
Drink menu 3
Espresso
Double Espresso
Coffee
Americano
Cappuccino
Cafe Latte
Latte Macchiato
Choco-milk
Pitcher Milk
Recipe file name: 424_x_CQube_SE20_Barista.mef
All drinks use both grinders at the same time,
50/50% from each grinder.
Hot Water
ESPRESSO DRINKS
35
PROGRAMMING
CQube SE20 BARISTA
Clean machine
pen the door. Press ENTER on the cleaning panel
O
inside the door. Choose button X for each cleaning.
Cleaning Hot Key
See the pages for
cleaning programs
in order to perform
cleaning.
3
Press
4
5
Enter
6
7
8
9
10
11
12
36
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Clean Brewer
Clean Mixer
Clean Valves
Daily Milk Clean
Open\Rotate Brewer
Clean Grinder 1
Clean Grinder 2
Rinse Brewer
Milk Prime
Descale Espresso System
PROGRAMMING
CQube SE20 BARISTA
Counters
See the counter of each drink or total counters for all
drinks. It’s also possible to reset the drink counters.
Service Menu
Counters
Service Menu
Counters
Press ENTER
Press
Press
Counters
Beverages
ENTER
Beverage Counters
Per Beverage
ENTER
Drink 1
served xxx
Press
Press
Press
to
Drink 2
served xxx
go forward in the menu
Press
Press
Beverage Counter
Total Served
ENTER
Total Beverages
Served xxx
Press
Press
Beverage Counter
Master Total
ENTER
Master Total
Served xxx
Press
Press
Beverage Counter
Clear Counters
ENTER
Hold Enter to
Clear Counters
Hold ENTER key
ENTER
for 3 seconds
Press BACK to go back in the menu
Counters Cleared
Press Back
37
PROGRAMMING
CQube SE20 BARISTA
Counters
See the number of times cleaning has been performed
or reset the clean counter.
Service Menu
Counters
Press
Counters
Clean Counter
ENTER
Clean Counter
Brewer xxx
Press
to go forward in the menu
Clean Counter
Total xxx
Press
Press BACK to go back in the menu
Press
Counters
Water Filter
ENTER
Press
Water Filter
Reset Filter
ENTER
Reset? NO/YES
Months Left 6
Standard=6 months
Press
to go forward in the menu
Press
Water Filter
Interval 6
ENTER
Press BACK to go back in the menu
38
Water Filter
Interval 1-12
DIMENSION SKETCH
CQube SE20 BARISTA
Dimensions
CQube SE20 BARISTA
C
B
A
D
Model
A
B
C
D
CQube SE20 BARISTA
818mm
562mm
532mm
50mm
39
DIMENSION SKETCH
CQube SE20 BARISTA
Dimensions
CQube SE20
B
C
A
D
40
Model
A
B
C
D
E
CQube SE20
818mm
290mm
532mm
110mm
155mm
E
DIMENSION SKETCH
CQube SE20 BARISTA
Dimensions
BARISTA
B
C
A
Model
A
B
C
BARISTA
818mm
222mm
456mm
41
For the warranty to be valid the conditions for maintenance must have been
followed according to our instructions, proper precaution has been made and
warranty claim been issued without delay.
The affected equipment may not be used during awaiting service if there is any risk
that the damage or defect would worsen.
The warranty will not cover consumption supplies such as glassware, normal
maintenance such as cleaning of filters, contaminations in water, lime, incorrect
voltages, pressure or adjustment of water amounts.
The warranty will not cover damages of defects caused by incorrect handling and
operation of the appliance.
FOR SERVICE
Please contact your dealer
Your Dealer
www.creminternational.com
Download PDF
Similar pages